Advertisement for orthosearch.org.uk
Results 1 - 50 of 354
Results per page:
The Bone & Joint Journal
Vol. 106-B, Issue 3 | Pages 249 - 255
1 Mar 2024
Inclan PM Brophy RH Saccone NL Ma Y Pham V Yanik EL

Aims. The purpose of this study is to determine an individual’s age-specific prevalence of total knee arthroplasty (TKA) after cruciate ligament surgery, and to identify clinical and genetic risk factors associated with undergoing TKA. Methods. This study was a retrospective case-control study using the UK Biobank to identify individuals reporting a history of cruciate ligament surgery. Data from verbal history and procedural codes recorded through the NHS were used to identify instances of TKA. Patient clinical and genetic data were used to identify risk factors for progression from cruciate ligament surgery to TKA. Individuals without a history of cruciate ligament reconstruction were used for comparison. Results. A total of 2,576 individuals with a history of cruciate ligament surgery were identified, with 290 (11.25%) undergoing TKA. In patients with prior cruciate ligament surgery, prevalence of TKA was 0.75% at age 45 years, 9.10% at age 65 years, and 20.43% at age 80 years. Patients with prior cruciate ligament surgery were 4.6 times more likely to have undergone TKA by age 55 years than individuals without prior cruciate ligament surgery. In the cruciate ligament surgery cohort, BMI > 30 kg/m. 2. (odds ratio (OR) 4.01 (95% confidence interval (CI) 2.74 to 5.87)), a job that always involved heavy manual or physical labour (OR 2.72 (95% CI 1.57 to 4.71)), or a job that always involved walking and standing (OR 2.58 (95% CI 1.58 to 4.20)) were associated with greater TKA odds. No single-nucleotide polymorphism (SNP) was associated with risk of TKA following cruciate ligament surgery. Conclusion. Patients with a history of prior cruciate ligament surgery have substantially higher risk of TKA and undergo arthroplasty at a relatively younger age than individuals without a history of prior cruciate ligament surgery. Physically demanding work and obesity were associated with higher odds of TKA after cruciate ligament surgery, but no SNP was associated with risk of TKA. Cite this article: Bone Joint J 2024;106-B(3):249–255


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1230 - 1237
1 Oct 2019
Kayani B Konan S Horriat S Ibrahim MS Haddad FS

Aims. The aim of this study was to assess the effect of posterior cruciate ligament (PCL) resection on flexion-extension gaps, mediolateral soft-tissue laxity, fixed flexion deformity (FFD), and limb alignment during posterior-stabilized (PS) total knee arthroplasty (TKA). Patients and Methods. This prospective study included 110 patients with symptomatic osteoarthritis of the knee undergoing primary robot-assisted PS TKA. All operations were performed by a single surgeon using a standard medial parapatellar approach. Optical motion capture technology with fixed femoral and tibial registration pins was used to assess gaps before and after PCL resection in extension and 90° knee flexion. Measurements were made after excision of the anterior cruciate ligament and prior to bone resection. There were 54 men (49.1%) and 56 women (50.9%) with a mean age of 68 years (. sd. 6.2) at the time of surgery. The mean preoperative hip-knee-ankle deformity was 4.1° varus (. sd. 3.4). Results. PCL resection increased the mean flexion gap significantly more than the extension gap in the medial (2.4 mm (. sd. 1.5) vs 1.3 mm (. sd. 1.0); p < 0.001) and lateral (3.3 mm (. sd. 1.6) vs 1.2 mm (. sd. 0.9); p < 0.01) compartments. The mean gap differences after PCL resection created significant mediolateral laxity in flexion (gap difference: 1.1 mm (. sd. 2.5); p < 0.001) but not in extension (gap difference: 0.1 mm (. sd. 2.1); p = 0.51). PCL resection significantly improved the mean FFD (6.3° (. sd. 4.4) preoperatively vs 3.1° (. sd. 1.5) postoperatively; p < 0.001). There was a strong positive correlation between the preoperative FFD and change in FFD following PCL resection (Pearson’s correlation coefficient = 0.81; p < 0.001). PCL resection did not significantly affect limb alignment (mean change in alignment: 0.2° valgus (. sd. 1.2); p = 0.60). Conclusion. PCL resection creates flexion-extension mismatch by increasing the flexion gap more than the extension gap. The increase in the lateral flexion gap is greater than the increase in the medial flexion gap, which creates mediolateral laxity in flexion. Improvements in FFD following PCL resection are dependent on the degree of deformity before PCL resection. Cite this article: Bone Joint J 2019;101-B:1230–1237


The Bone & Joint Journal
Vol. 106-B, Issue 8 | Pages 808 - 816
1 Aug 2024
Hall AJ Cullinan R Alozie G Chopra S Greig L Clarke J Riches PE Walmsley P Ohly NE Holloway N

Aims. Total knee arthroplasty (TKA) with a highly congruent condylar-stabilized (CS) articulation may be advantageous due to increased stability versus cruciate-retaining (CR) designs, while mitigating the limitations of a posterior-stabilized construct. The aim was to assess ten-year implant survival and functional outcomes of a cemented single-radius TKA with a CS insert, performed without posterior cruciate ligament sacrifice. Methods. This retrospective cohort study included consecutive patients undergoing TKA at a specialist centre in the UK between November 2010 and December 2012. Data were collected using a bespoke electronic database and cross-referenced with national arthroplasty audit data, with variables including: preoperative characteristics, intraoperative factors, complications, and mortality status. Patient-reported outcome measures (PROMs) were collected by a specialist research team at ten years post-surgery. There were 536 TKAs, of which 308/536 (57.5%) were in female patients. The mean age was 69.0 years (95% CI 45.0 to 88.0), the mean BMI was 32.2 kg/m. 2. (95% CI 18.9 to 50.2), and 387/536 (72.2%) survived to ten years. There were four revisions (0.7%): two deep infections (requiring debridement and implant retention), one aseptic loosening, and one haemosiderosis. Results. Kaplan-Meier analysis demonstrated no difference in implant survival according to sex, age, or obesity status. Ten-year PROMs were available for 196/387 (50.6%) surviving patients and were excellent: mean Oxford Knee Score 34.4 (95% CI 32.7 to 36.1); mean Forgotten Joint Score (FJS) 51.2 (95% CI 16.1 to 86.3); mean EuroQol five-dimension five-level questionnaire score 69.9 (95% CI 46.8 to 93.0); 141/196 (71.9%) achieved the 22-point FJS patient-acceptable symptom state (PASS); and 156/196 (79.6%) were “very satisfied or satisfied”. Conclusion. This is the only large study reporting ten-year implant survival and functional outcomes of TKA using a cemented single-radius design and with a CS tibial bearing construct. The findings of excellent implant survival, safety, and functional outcomes indicate that this combination is a safe and effective option in routine TKA. Further investigation of this single-radius design TKA with CS tibial bearings with well-matched patient study groups will allow further insight into the performance of these implants. Cite this article: Bone Joint J 2024;106-B(8):808–816


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 8 | Pages 1046 - 1050
1 Aug 2007
Christen B Heesterbeek PV Wymenga A Wehrli U

We have examined the relationship between the size of the flexion gap and the anterior translation of the tibia in flexion during implantation of a posterior cruciate ligament (PCL)-retaining BalanSys total knee replacement (TKR). In 91 knees, the flexion gap and anterior tibial translation were measured intra-operatively using a custom-made, flexible tensor-spacer device. The results showed that for each increase of 1 mm in the flexion gap in the tensed knee a mean anterior tibial translation of 1.25 mm (SD 0.79, 95% confidence interval 1.13 to 1.37) was produced. When implanting a PCL-retaining TKR the surgeon should be aware that the tibiofemoral contact point is related to the choice of thickness of the polyethylene insert. An additional thickness of polyethylene insert of 2 mm results in an approximate increase in tibial anterior translation of 2.5 mm while the flexed knee is distracted with a force of between 100 N and 200 N


The Journal of Bone & Joint Surgery British Volume
Vol. 65-B, Issue 2 | Pages 204 - 209
1 Mar 1983
Pournaras J Symeonides P Karkavelas G

The significance of the posterior cruciate ligament in the stability of the knee was investigated in dogs and it was compared with that of the anterior cruciate ligament by studying the changes produced in the knee after transection of either ligament. Osteophyte formation and changes in articular cartilage were less prominent after division of the posterior cruciate ligament. A complete longitudinal tear of the medial meniscus was found in eight out of the 10 dogs who had undergone section of the anterior cruciate but in none of the 10 with section of the posterior cruciate. It appears that, in dogs at least, the posterior cruciate ligament is less important than the anterior in the stability of the knee


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 5 | Pages 784 - 786
1 Nov 1988
Mitsou A Vallianatos P Piskopakis N Nicolaou P

In 30 rabbits, the medial meniscus was used to replace the anterior or posterior cruciate ligament. The changes that took place were followed in histological sections, obtained both from the area of insertion into bone and from the intra-articular part of the graft. There was a gradual differentiation to chondroid tissue, with subsequent calcific deposition and no appearance of normal ligamentous tissue. The strength of the graft after 52 weeks was only one-quarter of that of the normal ligament. Our results do not justify the use of the meniscus to replace a torn cruciate ligament


The Journal of Bone & Joint Surgery British Volume
Vol. 59-B, Issue 1 | Pages 15 - 19
1 Feb 1977
Tillberg B

An operation using either the medial or the lateral meniscus to effect the late repair of torn cruciate ligaments is described. Forty-three patients under fifty years of age who were unable to return to their work because of severe joint laxity have been treated in this way and reviewed after one to thirty years. Sagittal stability was measured by a special apparatus, and a comparison was made between normal knees and affected knees before and after operation. The review of forty-five knees showed normal stability in thirty-one, slight instability in twelve and no improvement in two. Forty-one patients had returned to their former work: twenty-two complained of instability when tired; all had pain-free joints. The use of a meniscus for the reconstruction of either cruciate ligament is considered to be simple, safe and effective


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 10 | Pages 1381 - 1384
1 Oct 2010
Jacobi M Reischl N Wahl P Gautier E Jakob RP

We investigated the role of a functional brace worn for four months in the treatment of patients with an acute isolated tear of the posterior cruciate ligament to determine whether reduction of the posterior tibial translation during the healing period would give an improved final position of the tibia. The initial and follow-up stability was tested by Rolimeter arthrometry and radiography. The clinical outcome was evaluated using the Lysholm score, the Tegner score and the International Knee Documentation Committee scoring system at follow-up at one and two years. In all, 21 patients were studied, 21 of whom had completed one-year and 17 a two-year follow-up. The initial mean posterior sag (Rolimeter measurement) of 7.1 mm (5 to 10) was significantly reduced after 12 months to a mean of 2.3 mm (0 to 6, p < 0.001) and to a mean of 3.2 mm (2 to 7, p = 0.001) after 24 months. Radiological measurement gave similar results. The mean pre-injury Lysholm score was normal at 98 (95 to 100). At follow-up, a slight decrease in the mean values was observed to 94.0 (79 to 100, p = 0.001) at one year and 94.0 (88 to 100, p = 0.027, at two years). We concluded that the posterior cruciate ligament has an intrinsic healing capacity and, if the posteriorly translated tibia is reduced to a physiological position, it can heal with less attentuation. The applied treatment produces a good to excellent functional result


Bone & Joint Research
Vol. 11, Issue 7 | Pages 494 - 502
20 Jul 2022
Kwon HM Lee J Koh Y Park KK Kang K

Aims. A functional anterior cruciate ligament (ACL) or posterior cruciate ligament (PCL) has been assumed to be required for patients undergoing unicompartmental knee arthroplasty (UKA). However, this assumption has not been thoroughly tested. Therefore, this study aimed to assess the biomechanical effects exerted by cruciate ligament-deficient knees with medial UKAs regarding different posterior tibial slopes. Methods. ACL- or PCL-deficient models with posterior tibial slopes of 1°, 3°, 5°, 7°, and 9° were developed and compared to intact models. The kinematics and contact stresses on the tibiofemoral joint were evaluated under gait cycle loading conditions. Results. Anterior translation increased in ACL-deficient UKA cases compared with intact models. In contrast, posterior translation increased in PCL-deficient UKA cases compared with intact models. As the posterior tibial slope increased, anterior translation of ACL-deficient UKA increased significantly in the stance phase, and posterior translation of PCL-deficient UKA increased significantly in the swing phase. Furthermore, as the posterior tibial slope increased, contact stress on the other compartment increased in cruciate ligament-deficient UKAs compared with intact UKAs. Conclusion. Fixed-bearing medial UKA is a viable treatment option for patients with cruciate ligament deficiency, providing a less invasive procedure and allowing patient-specific kinematics to adjust posterior tibial slope. Patient selection is important, and while AP kinematics can be compensated for by posterior tibial slope adjustment, rotational stability is a prerequisite for this approach. ACL- or PCL-deficient UKA that adjusts the posterior tibial slope might be an alternative treatment option for a skilled surgeon. Cite this article: Bone Joint Res 2022;11(7):494–502


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 5 | Pages 671 - 674
1 Jul 2003
Straw R Kulkarni S Attfield S Wilton TJ

We report the results of a prospective randomised trial which assessed the role of the posterior cruciate ligament (PCL) following total knee replacement (Genesis I; Smith and Nephew, Memphis, Tennessee). Over a four-year period, 211 patients underwent total knee replacement by the senior author (TJW). They were randomised at surgery to have the PCL either retained, excised or substituted with a posterior stabilised insert. If it was not possible to retain the ligament due to soft-tissue imbalance, it was released from its tibial insertion until suitable tension was obtained. This created a fourth group, those who were intended preoperatively to have the ligament retained, but in whom it was partially released as a result of findings at the time of surgery. All patients were evaluated using the Knee Society rating system (adapted from Insall). A total of 188 patients (212 knees) was available for follow-up at a mean of 3.5 years after surgery. Preoperatively, there was a varus deformity in 191 knees (90%) and a valgus deformity in 21 (10%). There were no statistical differences in the knee or function scores or the range of movement between the excised, retained and substituted groups. There were, however, significantly worse knee and function scores in the group in whom the PCL was released (p = 0.002)


The Journal of Bone & Joint Surgery British Volume
Vol. 50-B, Issue 2 | Pages 334 - 341
1 May 1968
Trickey EL

1. Seventeen cases of knee injury are described in which the predominant lesion was rupture of the posterior cruciate ligament. Seven were treated conservatively and ten by surgical repair. 2. Most cases occurred in motor cyclists. 3. The extent of the rupture should be determined by examination under anaesthesia. 4. Early surgical repair is indicated for complete rupture. 5. An effective method of repair is described


Bone & Joint Research
Vol. 3, Issue 4 | Pages 95 - 100
1 Apr 2014
Kaneyama R Otsuka M Shiratsuchi H Oinuma K Miura Y Tamaki T

Objectives. Because posterior cruciate ligament (PCL) resection makes flexion gaps wider in total knee replacement (TKR), preserving or sacrificing a PCL affects the gap equivalence; however, there are no criteria for the PCL resection that consider gap situations of each knee. This study aims to investigate gap characteristics of knees and to consider the criteria for PCL resection. Methods. The extension and flexion gaps were measured, first with the PCL preserved and subsequently with the PCL removed (in cases in which posterior substitute components were selected). The PCL preservation or sacrifice was solely determined by the gap measurement results, without considering other functions of the PCL such as ‘roll back.’. Results. Wide variations were observed in the extension and flexion gaps. The flexion gaps were significantly larger than the extension gaps. Cases with 18 mm or more flexion gap and with larger flexion than extension gap were implanted with cruciate retaining component. A posterior substitute component was implanted with the other cases. Conclusions. In order to make adequate gaps, it is important to decide whether to preserve the PCL based on the intra-operative gap measurements made with the PCL intact. Cite this article: Bone Joint Res 2014;3:95–100


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 9 | Pages 1169 - 1172
1 Sep 2006
Khanduja V Somayaji HS Harnett P Utukuri M Dowd GSE

We report a retrospective analysis of the results of combined arthroscopically-assisted posterior cruciate ligament reconstruction and open reconstruction of the posterolateral corner in 19 patients with chronic (three or more months) symptomatic instability and pain in the knee. All the operations were performed between 1996 and 2003 and all the patients were assessed pre- and post-operatively by physical examination and by applying three different ligament rating scores. All also had weight-bearing radiographs, MR scans and an examination under anaesthesia and arthroscopy pre-operatively. The posterior cruciate ligament reconstruction was performed using an arthroscopically-assisted single anterolateral bundle technique and the posterolateral corner structures were reconstructed using an open Larson type of tenodesis. The mean follow up was 66.8 months (24 to 110). Pre-operatively, all the patients had a grade III posterior sag according to Clancy and demonstrated more than 20° of external rotation compared with the opposite normal knee on the Dial test. Post-operatively, seven patients (37%) had no residual posterior sag, 11 (58%) had a grade I posterior sag and one (5%) had a grade II posterior sag. In five patients (26%) there was persistent minimal posterolateral laxity. The Lysholm score improved from a mean of 41.2 (28 to 53) to 76.5 (57 to 100) (p = 0.0001) and the Tegner score from a mean of 2.6 (1 to 4) to 6.4 (4 to 9) (p = 0.0001). We conclude that while a combined reconstruction of chronic posterior cruciate ligament and posterolateral corner instability improves the function of the knee, it does not restore complete stability


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 3 | Pages 450 - 456
1 Apr 2004
Nakagawa S Johal P Pinskerova V Komatsu T Sosna A Williams A Freeman MAR

The posterior cruciate ligament (PCL) was imaged by MRI throughout flexion in neutral tibial rotation in six cadaver knees, which were also dissected, and in 20 unloaded and 13 loaded living (squatting) knees. The appearance of the ligament was the same in all three groups. In extension the ligament is curved concave-forwards. It is straight, fully out-to-length and approaching vertical from 60° to 120°, and curves convex-forwards over the roof of the intercondylar notch in full flexion. Throughout flexion the length of the ligament does not change, but the separations of its attachments do. We conclude that the PCL is not loaded in the unloaded cadaver knee and therefore, since its appearance in all three groups is the same, that it is also unloaded in the living knee during flexion. The posterior fibres may be an exception in hyperextension, probably being loaded either because of posterior femoral lift-off or because of the forward curvature of the PCL. These conclusions relate only to everyday life: none may be drawn with regard to more strenuous activities such as sport or in trauma


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 4 | Pages 510 - 512
1 May 2001
Gill GS Joshi AB

We analysed the long-term results with a mean follow-up of 10.2 years, of 66 total knee replacements in 42 patients with rheumatoid arthritis. In all cases the posterior cruciate ligament was retained. There were only three complications (4.5%). Revision surgery was necessary in five knees (7.6%), including one (1.5%) with infection. At the final follow-up, 75.8% of knees were rated excellent clinically. Only 15% had an excellent function score. The survival rate of the implant was 90.7% at 19 years. The clinical, radiological and survivorship analysis shows that the posterior-cruciate-retaining knee arthroplasty performs well in rheumatoid arthritis


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 6 | Pages 895 - 900
1 Nov 1995
Shino K Horibe S Nakata K Maeda A Hamada M Nakamura N

We assessed arthroscopically 22 young athletes with an isolated acute posterior cruciate ligament (PCL) injury. Four had significant damage to the articular cartilage of the medial femorotibial compartment and were advised not to resume sports. Three underwent PCL reconstruction because of a reparable meniscal tear or instability. The other 15 were treated conservatively and resumed sport. At an average follow-up of 51 months, one had developed arthritic symptoms due to newly-developed severe chondral damage to the medial femoral condyle, but none of the other 14 had developed arthritic symptoms and most remained athletically active. Severe chondral damage should be seen at an early arthroscopy. Knees with an isolated injury to the PCL with concomitant articular damage may be successfully managed by conservative treatment


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 1 | Pages 94 - 99
1 Jan 1988
Bradley J FitzPatrick D Daniel D Shercliff T O'Connor J

We have studied the kinematics of the knee in the sagittal plane, using a four-bar linkage as model, and assuming that a "neutral fibre" in each ligament remains isometric throughout flexion. We devised a computer program to calculate the distance separating any pair of points, one on each bone, for various cruciate attachments at various angles of flexion. The parameters for the linkage in four cadaveric knees were obtained by marking the centre of attachment of the cruciate ligaments with tacks and taking lateral radiographs. The movements of the bones were then calculated, in the computer model, for various attachments of "replacement" ligament fibres, the distance between the attachment sites being plotted against the angle of flexion. It was then possible to define zones around the isometric attachment points within which changes in length would be predictable. Our results show that the position of the femoral sites of attachment of both anterior and posterior cruciate replacement was more critical than that of the tibial attachments


The Bone & Joint Journal
Vol. 95-B, Issue 7 | Pages 917 - 922
1 Jul 2013
Sabouret P Lavoie F Cloutier J

We report on the long-term results of 163 bicruciate-retaining Hermes 2C total knee replacements in 130 patients at a mean follow-up of 22.4 years (20.3 to 23.5). Even when the anterior cruciate ligament had a partially degenerative appearance it was preserved as long as the knee had a normal anterior drawer and Lachman’s test pre-operatively. The description and surgical technique of this minimally constrained prosthesis were published in 1983 and the ten-year clinical results in 1999.

A total of 12% of the knees (20 of 163) in this study were revised because of wear of the polyethylene tibial insert. Excellent stability was achieved and the incidence of aseptic component loosening was 4.3% (seven of 163). The survival rate using revision for any reason as the endpoint was 82% (95% confidence interval 76.2 to 88.0).

Although this series included a relatively small number of replacements, it demonstrated that the anterior cruciate ligament, even when partially degenerated at the time of TKR, remained functional and provided adequate stability at a long-term follow-up.

Cite this article: Bone Joint J 2013;95-B:917–22.


The Bone & Joint Journal
Vol. 97-B, Issue 9 | Pages 1220 - 1225
1 Sep 2015
Chen LB Wang H Tie K Mohammed A Qi YJ

A total of 22 patients with a tibial avulsion fracture involving the insertion of the posterior cruciate ligament (PCL) with grade II or III posterior laxity were reduced and fixed arthroscopically using routine anterior and double posteromedial portals. A double-strand Ethibond suture was inserted into the joint and wrapped around the PCL from anterior to posterior to secure the ligament above the avulsed bony fragment. Two tibial bone tunnels were created using the PCL reconstruction guide, aiming at the medial and lateral borders of the tibial bed. The ends of the suture were pulled out through the bone tunnels and tied over the tibial cortex between the openings of the tunnels to reduce and secure the bony fragment. Satisfactory reduction of the fracture was checked arthroscopically and radiographically.

The patients were followed-up for a mean of 24.5 months (19 to 28). Bone union occurred six weeks post-operatively. At final follow-up, all patients had a negative posterior drawer test and a full range of movement. KT-1000 arthrometer examination showed that the mean post-operative side-to-side difference improved from 10.9 mm (standard deviation (sd) 0.7) pre-operatively to 1.5 mm (sd 0.6) (p = 0.001). The mean Tegner and the International Knee Documentation Committee scores improved significantly (p = 0.001). The mean Lysholm score at final follow-up was 92.0 (85 to 96).

We conclude that this technique is convenient, reliable and minimally invasive and successfully restores the stability and function of the knee.

Cite this article: Bone Joint J 2015;97-B:1220–5.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 6 | Pages 885 - 885
1 Jun 2005
RAISBECK CC


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 4 | Pages 480 - 491
1 May 2004
Dowd GSE


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 3 | Pages 389 - 392
1 Apr 2003
Misra AN Hussain MRA Fiddian NJ Newton G

We randomised 129 knees which were to be replaced using a standard posterior-cruciate-ligament (PCL)-retaining cemented total knee replacement into two groups. In one the PCL was retained in the normal way and in the other it was resected. They were well matched, with a predominance of women, and a mean age of 67 years.

There was no statistically significant difference in the Hospital for Special Surgery scores at a mean of 57 months (56 to 60) between the two groups although 21 patients (24 knees) were lost to follow-up. Relief from pain, correction of deformity, range of movement, stability and strength were comparable in both. Radiological assessment showed femoral rollback in approximately 20% of knees with a slightly higher incidence in the PCL-resected group. There was no significant loosening detected in either group at review at two years.

At five years, one knee in the PCL-retained group had been revised because of infection and one patient in each group was awaiting revision for loosening.

Our findings have shown no significant difference in the five-year results for a PCL-retaining total knee replacement if the PCL is excised or preserved. This suggests two important points. First, the PCL is not functional in most patients with a total knee replacement even when retained. Secondly, patients with an excised PCL show a good result with a PCL-retaining implant, thereby questioning the need for a posterior stabilised design in such a situation.


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 2 | Pages 304 - 305
1 Mar 1999
Kumar A Bickerstaff DR Grimwood JS Suvarna SK

A 35-year-old man was seen with pain in the back of the knee. MRI showed a mass in the anterior cruciate ligament. Biopsy indicated mucoid degeneration. Arthroscopic resection of the ligament was carried out, with relief of symptoms.


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 5 | Pages 777 - 777
1 Jul 2002
Dandy D


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 5 | Pages 827 - 828
1 Nov 1986
Kaelin A Hulin P Carlioz H

Instability of the knee is frequently found in association with congenital leg-length discrepancy. We have studied six such patients clinically, radiologically and arthroscopically. Clinical signs of knee instability and significant radiological changes were present in all, and at arthroscopy the anterior cruciate ligament was completely absent in four patients and functionless in the other two. This deficiency appears to be a congenital condition which may predispose to meniscus injury or retropatellar pain; it may also lead to subluxation or dislocation of the knee during leg-lengthening procedures.


The Journal of Bone & Joint Surgery British Volume
Vol. 64-B, Issue 1 | Pages 92 - 94
1 Feb 1982
Dandy D Pusey R


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 1 | Pages 147 - 147
1 Jan 2002
FORSTER M


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 4 | Pages 617 - 619
1 Jul 1992
Christen B Jakob R

We reviewed retrospectively 490 patellar ligament reconstructions for cruciate ligament injuries performed from 1980 to 1990. There were six cases of patellar splitting and three displaced patellar fractures in donor knees. The fissure fractures all occurred during the removal of the patellar bone block. The displaced fractures were sustained during early rehabilitation, and in two of the three patients, involved the normal contralateral knee. The major reasons for this complication were imprecise saw cuts, spreading osteotomies, and the use of a too large patellar bone block. When a trapezoidal bone block is used to self-lock in the femoral tunnel, this should preferably be taken from the tibia. Special care is needed in rehabilitation when the graft has been taken from the contralateral knee.


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 5 | Pages 747 - 747
1 Nov 1986
Ross A Chesterman P


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 2 | Pages 225 - 230
1 Mar 1990
Staubli H Jakob R

We evaluated the accuracy of six clinical tests for posterior instability in 24 knees with acute surgically-proven posterior cruciate ligament injuries and intact anterior cruciate ligaments. We also performed stress radiography under anaesthesia. The gravity sign and the posterior drawer test in near extension and its passive reduction were diagnostic in 20 of the 24 knees, and the active reduction of posterior subluxation was diagnostic in 18. The reversed pivot shift sign helped to diagnose severe posterior and posterolateral subluxations, but the external rotation recurvatum test was negative in all 24 knees. Stress radiography in near extension revealed a highly significant increase in posterior tibial subluxation in the injured knees.


The Journal of Bone & Joint Surgery British Volume
Vol. 60-B, Issue 4 | Pages 520 - 522
1 Nov 1978
Jenkins D

Carbon fibre appears to induce the formation of tendon in both animals and humans. Experiments have been conducted in sheep in which new anterior cruciate ligaments have been induced in response to the implantation of filamentous carbon fibre. Long-term studies indicate that the carbon fibre slowly breaks up at the site of implantation and later begins to appear in the regional lymph nodes.


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1271 - 1278
1 Dec 2023
Rehman Y Korsvold AM Lerdal A Aamodt A

Aims. This study compared patient-reported outcomes of three total knee arthroplasty (TKA) designs from one manufacturer: one cruciate-retaining (CR) design, and two cruciate-sacrificing designs, anterior-stabilized (AS) and posterior-stabilized (PS). Methods. Patients scheduled for primary TKA were included in a single-centre, prospective, three-armed, blinded randomized trial (n = 216; 72 per group). After intraoperative confirmation of posterior cruciate ligament (PCL) integrity, patients were randomly allocated to receive a CR, AS, or PS design from the same TKA system. Insertion of an AS or PS design required PCL resection. The primary outcome was the mean score of all five subscales of the Knee injury and Osteoarthritis Outcome Score (KOOS) at two-year follow-up. Secondary outcomes included all KOOS subscales, Oxford Knee Score, EuroQol five-dimension health questionnaire, EuroQol visual analogue scale, range of motion (ROM), and willingness to undergo the operation again. Patient satisfaction was also assessed. Results. Patients reported similar levels of pain, function, satisfaction, and general health regardless of the prosthetic design they received. Mean maximal flexion (129° (95% confidence interval (CI) 127° to 131°) was greater in the PS group than in the CR (120° (95% CI 121° to 124°)) and AS groups (122° (95% CI 120° to 124°)). Conclusion. Despite differences in design and constraint, CR, AS, and PS designs from a single TKA system resulted in no differences in patient-reported outcomes at two-year follow-up. PS patients had statistically better ROM, but the clinical significance of this finding is unclear. Cite this article: Bone Joint J 2023;105-B(12):1271–1278


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 59 - 65
1 Jun 2020
Kwon Y Arauz P Peng Y Klemt C

Aims. The removal of the cruciate ligaments in total knee arthroplasty (TKA) has been suggested as a potential contributing factor to patient dissatisfaction, due to alteration of the in vivo biomechanics of the knee. Bicruciate retaining (BCR) TKA allows the preservation of the cruciate ligaments, thus offering the potential to reproduce healthy kinematics. The aim of this study was to compare in vivo kinematics between the operated and contralateral knee in patients who have undergone TKA with a contemporary BCR design. Methods. A total of 29 patients who underwent unilateral BCR TKA were evaluated during single-leg deep lunges and sit-to-stand tests using a validated computer tomography and fluoroscopic imaging system. In vivo six-degrees of freedom (6DOF) kinematics were compared between the BCR TKA and the contralateral knee. Results. During single-leg deep lunge, BCR TKAs showed significantly less mean posterior femoral translation (13 mm; standard deviation (SD) 4) during terminal flexion, compared with the contralateral knee (16.6 mm, SD 3.7; p = 0.001). Similarly, BCR TKAs showed significantly less mean femoral rollback (11.6 mm (SD 4.5) vs 14.4 mm (SD 4.6); p < 0.043) during sit-to-stand. BCR TKAs showed significantly reduced internal rotation during many parts of the strenuous flexion activities particularly during high-flexion lunge (4° (SD 5.6°) vs 6.5° (SD 6.1°); p = 0.051) and during sit-to-stand (4.5° (SD 6°) vs 6.9° (SD 6.3°); p = 0.048). Conclusion. The contemporary design of BCR TKA showed asymmetrical flexion-extension and internal-external rotation, suggesting that the kinematics are not entirely reproduced during strenuous activities. Future studies are required to establish the importance of patient factors, component orientation and design, in optimizing kinematics in patients who undergo BCR TKA. Cite this article: Bone Joint J 2020;102-B(6 Supple A):59–65


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 49 - 58
1 Jun 2020
Mullaji A

Aims. The aims of this study were to determine the effect of osteophyte excision on deformity correction and soft tissue gap balance in varus knees undergoing computer-assisted total knee arthroplasty (TKA). Methods. A total of 492 consecutive, cemented, cruciate-substituting TKAs performed for varus osteoarthritis were studied. After exposure and excision of both cruciates and menisci, it was noted from operative records the corrective interventions performed in each case. Knees in which no releases after the initial exposure, those which had only osteophyte excision, and those in which further interventions were performed were identified. From recorded navigation data, coronal and sagittal limb alignment, knee flexion range, and medial and lateral gap distances in maximum knee extension and 90° knee flexion with maximal varus and valgus stresses, were established, initially after exposure and excision of both cruciate ligaments, and then also at trialling. Knees were defined as ‘aligned’ if the hip-knee-ankle axis was between 177° and 180°, (0° to 3° varus) and ‘balanced’ if medial and lateral gaps in extension and at 90° flexion were within 2 mm of each other. Results. Of 50 knees (10%) with no soft tissue releases (other than cruciate ligaments), 90% were aligned, 81% were balanced, and 73% were aligned and balanced. In 288 knees (59%) only osteophyte excision was performed by subperiosteally releasing the deep medial collateral ligament. Of these, 98% were aligned, 80% were balanced, and 79% were aligned and balanced. In 154 knees (31%), additional procedures were performed (reduction osteotomy, posterior capsular release, and semimembranosus release). Of these, 89% were aligned, 68% were balanced, and 66% were aligned and balanced. The superficial medial collateral ligament was not released in any case. Conclusion. Two-thirds of all knees could be aligned and balanced with release of the cruciate ligaments alone and excision of osteophytes. Excision of osteophytes can be a useful step towards achieving deformity correction and gap balance without having to resort to soft tissue release in varus knees while maintaining classical coronal and sagittal alignment of components. Cite this article: Bone Joint J 2020;102-B(6 Supple A):49–58


Bone & Joint Research
Vol. 8, Issue 3 | Pages 126 - 135
1 Mar 2019
Sekiguchi K Nakamura S Kuriyama S Nishitani K Ito H Tanaka Y Watanabe M Matsuda S

Objectives. Unicompartmental knee arthroplasty (UKA) is one surgical option for treating symptomatic medial osteoarthritis. Clinical studies have shown the functional benefits of UKA; however, the optimal alignment of the tibial component is still debated. The purpose of this study was to evaluate the effects of tibial coronal and sagittal plane alignment in UKA on knee kinematics and cruciate ligament tension, using a musculoskeletal computer simulation. Methods. The tibial component was first aligned perpendicular to the mechanical axis of the tibia, with a 7° posterior slope (basic model). Subsequently, coronal and sagittal plane alignments were changed in a simulation programme. Kinematics and cruciate ligament tensions were simulated during weight-bearing deep knee bend and gait motions. Translation was defined as the distance between the most medial and the most lateral femoral positions throughout the cycle. Results. The femur was positioned more medially relative to the tibia, with increasing varus alignment of the tibial component. Medial/lateral (ML) translation was smallest in the 2° varus model. A greater posterior slope posteriorized the medial condyle and increased anterior cruciate ligament (ACL) tension. ML translation was increased in the > 7° posterior slope model and the 0° model. Conclusion. The current study suggests that the preferred tibial component alignment is between neutral and 2° varus in the coronal plane, and between 3° and 7° posterior slope in the sagittal plane. Varus > 4° or valgus alignment and excessive posterior slope caused excessive ML translation, which could be related to feelings of instability and could potentially have negative effects on clinical outcomes and implant durability. Cite this article: K. Sekiguchi, S. Nakamura, S. Kuriyama, K. Nishitani, H. Ito, Y. Tanaka, M. Watanabe, S. Matsuda. Bone Joint Res 2019;8:126–135. DOI: 10.1302/2046-3758.83.BJR-2018-0208.R2


Bone & Joint Open
Vol. 2, Issue 6 | Pages 414 - 421
1 Jun 2021
Kim SK Nguyen C Avins AL Abrams GD

Aims. The aim of this study was to screen the entire genome for genetic markers associated with risk for anterior cruciate ligament (ACL) and posterior cruciate ligament (PCL) injury. Methods. Genome-wide association (GWA) analyses were performed using data from the Kaiser Permanente Research Board (KPRB) and the UK Biobank. ACL and PCL injury cases were identified based on electronic health records from KPRB and the UK Biobank. GWA analyses from both cohorts were tested for ACL and PCL injury using a logistic regression model adjusting for sex, height, weight, age at enrolment, and race/ethnicity using allele counts for single nucleotide polymorphisms (SNPs). The data from the two GWA studies were combined in a meta-analysis. Candidate genes previously reported to show an association with ACL injury in athletes were also tested for association from the meta-analysis data from the KPRB and the UK Biobank GWA studies. Results. There was a total of 2,214 cases of ACL and PCL injury and 519,869 controls within the two cohorts, with three loci demonstrating a genome-wide significant association in the meta-analysis: INHBA, AEBP2, and LOC101927869. Of the eight candidate genes previously studied in the literature, six were present in the current dataset, and only COL3A1 (rs1800255) showed a significant association (p = 0.006). Conclusion. Genetic markers in three novel loci in this study and one previously-studied candidate gene were identified as potential risk factors for ACL and PCL injury and deserve further validation and investigation of molecular mechanisms. Cite this article: Bone Jt Open 2021;2(6):414–421


Bone & Joint Research
Vol. 9, Issue 9 | Pages 593 - 600
1 Sep 2020
Lee J Koh Y Kim PS Kang KW Kwak YH Kang K

Aims. Unicompartmental knee arthroplasty (UKA) has become a popular method of treating knee localized osteoarthritis (OA). Additionally, the posterior cruciate ligament (PCL) is essential to maintaining the physiological kinematics and functions of the knee joint. Considering these factors, the purpose of this study was to investigate the biomechanical effects on PCL-deficient knees in medial UKA. Methods. Computational simulations of five subject-specific models were performed for intact and PCL-deficient UKA with tibial slopes. Anteroposterior (AP) kinematics and contact stresses of the patellofemoral (PF) joint and the articular cartilage were evaluated under the deep-knee-bend condition. Results. As compared to intact UKA, there was no significant difference in AP translation in PCL-deficient UKA with a low flexion angle, but AP translation significantly increased in the PCL-deficient UKA with high flexion angles. Additionally, the increased AP translation became decreased as the posterior tibial slope increased. The contact stress in the PF joint and the articular cartilage significantly increased in the PCL-deficient UKA, as compared to the intact UKA. Additionally, the increased posterior tibial slope resulted in a significant decrease in the contact stress on PF joint but significantly increased the contact stresses on the articular cartilage. Conclusion. Our results showed that the posterior stability for low flexion activities in PCL-deficient UKA remained unaffected; however, the posterior stability for high flexion activities was affected. This indicates that a functional PCL is required to ensure normal stability in UKA. Additionally, posterior stability and PF joint may reduce the overall risk of progressive OA by increasing the posterior tibial slope. However, the excessive posterior tibial slope must be avoided. Cite this article: Bone Joint Res 2020;9(9):593–600


The Bone & Joint Journal
Vol. 101-B, Issue 9 | Pages 1058 - 1062
1 Sep 2019
van Kuijk KSR Reijman M Bierma-Zeinstra SMA Waarsing JH Meuffels DE

Aims. Little is known about the risk factors that predispose to a rupture of the posterior cruciate ligament (PCL). Identifying risk factors is the first step in trying to prevent a rupture of the PCL from occurring. The morphology of the knee in patients who rupture their PCL may differ from that of control patients. The purpose of this study was to identify any variations in bone morphology that are related to a PCL. Patients and Methods. We compared the anteroposterior (AP), lateral, and Rosenberg view radiographs of 94 patients with a ruptured PCL to a control group of 168 patients matched by age, sex, and body mass index (BMI), but with an intact PCL after a knee injury. Statistical shape modelling software was used to assess the shape of the knee and determine any difference in anatomical landmarks. Results. We found shape variants on the AP and Rosenberg view radiographs to be significantly different between patients who tore their PCL and those with an intact PCL after a knee injury. Overall, patients who ruptured their PCL have smaller intercondylar notches and smaller tibial eminences than control patients. Conclusion. This study shows that differences in the shape of the knee are associated with the presence of a PCL rupture after injury. A smaller and more sharply angled intercondylar notch and a more flattened tibial eminence are related to PCL rupture. This suggests that the morphology of the knee is a risk factor for sustaining a PCL rupture. Cite this article: Bone Joint J 2019;101-B:1058–1062


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 7 | Pages 907 - 913
1 Jul 2011
Ward TR Burns AW Gillespie MJ Scarvell JM Smith PN

Bicruciate-stabilised total knee replacement (TKR) aims to restore normal kinematics by replicating the function of both cruciate ligaments. We performed a prospective, randomised controlled trial in which bicruciate- and posterior-stabilised TKRs were implanted in 13 and 15 osteo-arthritic knees, respectively. The mean age of the bicruciate-stabilised group was 63.9 years (. sd. 10.00) and that of the posterior-stabilised group 63.2 years (. sd. 6.7). A control group comprised 14 normal subjects with a mean age of 67.9 years (. sd. 7.9). The patellar tendon angle (PTA) was measured one week pre-operatively and at seven weeks post-operatively during knee extension, flexion and step-up exercises. At near full extension during step-up, the bicruciate-stabilised TKR produced a higher mean PTA than the posterior-stabilised TKR, indicating that the bicruciate design at least partially restored the kinematic role of the anterior cruciate ligament. The bicruciate-stabilised TKR largely restored the pre-operative kinematics, whereas the posterior-stabilised TKR resulted in a consistently lower PTA at all activities. The PTA in the pre-operative knees was higher than in the control group during the step-up and at near full knee extension. Overall, both groups generated a more normal PTA than that seen in previous studies in high knee flexion. This suggested that both designs of TKR were more effective at replicating the kinematic role of the posterior cruciate ligament than those used in previous studies


Bone & Joint Research
Vol. 9, Issue 6 | Pages 258 - 267
1 Jun 2020
Yao X Zhou K Lv B Wang L Xie J Fu X Yuan J Zhang Y

Aims. Tibial plateau fractures (TPFs) are complex injuries around the knee caused by high- or low-energy trauma. In the present study, we aimed to define the distribution and frequency of TPF lines using a 3D mapping technique and analyze the rationalization of divisions employed by frequently used classifications. Methods. In total, 759 adult patients with 766 affected knees were retrospectively reviewed. The TPF fragments on CT were multiplanar reconstructed, and virtually reduced to match a 3D model of the proximal tibia. 3D heat mapping was subsequently created by graphically superimposing all fracture lines onto a tibia template. Results. The cohort included 405 (53.4%) cases with left knee injuries, 347 (45.7%) cases with right knee injuries, and seven (0.9%) cases with bilateral injuries. On mapping, the hot zones of the fracture lines were mainly concentrated around the anterior cruciate ligament insertion, posterior cruciate ligament insertion, and the inner part of the lateral condyle that extended to the junctional zone between Gerdy’s tubercle and the tibial tubercle. Moreover, the cold zones were scattered in the posteromedial fragment, superior tibiofibular syndesmosis, Gerdy’s tubercle, and tibial tubercle. TPFs with different Orthopaedic Trauma Association/AO Foundation (OTA/AO) subtypes showed peculiar characteristics. Conclusion. TPFs occurred more frequently in the lateral and intermedial column than in the medial column. Fracture lines of tibial plateau occur frequently in the transition zone with marked changes in cortical thickness. According to 3D mapping, the four-column and nine-segment classification had a high degree of matching as compared to the frequently used classifications. Cite this article: Bone Joint Res 2020;9(6):258–267


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 10 | Pages 1328 - 1333
1 Oct 2008
Jackson WFM van der Tempel WM Salmon LJ Williams HA Pinczewski LA

We evaluated the long-term outcome of isolated endoscopically-assisted posterior cruciate ligament reconstruction in 26 patients using hamstring tendon autografts after failure of conservative management. At ten years after surgery the mean International Knee Documentation Committee subjective knee score was 87 (. sd. 14) of a possible 100 points. Regular participation in moderate to strenuous activities was possible for only seven patients pre-operatively; this increased to 23 patients post-operatively. The mean Lysholm score improved from 64 (. sd. 15) to 90 (. sd. 14) at ten years (p = 0.001). At ten years endoscopic reconstruction of the posterior cruciate ligament with hamstring tendon autograft is effective in reducing knee symptoms. Of the series, 22 patients underwent radiological assessment for the development of osteoarthritis using the Kellgren-Lawrence grading scale. In four patients, grade 2 changes with loss of joint space was observed and another four patients showed osteophyte formation with moderate joint space narrowing (grade 3). These findings compared favourably with non-operatively managed injuries of the posterior cruciate ligament. This procedure for symptomatic patients with posterior cruciate ligament laxity who have failed conservative management offers good results


The Journal of Bone & Joint Surgery British Volume
Vol. 49-B, Issue 1 | Pages 112 - 120
1 Feb 1967
Katz MP Grogono BJS Soper KC

Five knees with congenital dislocation were explored. The cruciate ligaments were found to be absent or hypoplastic. The results obtained by reconstructing an anterior cruciate ligament appear to be good. On the basis of dissections of foetal knees we believe that the cruciate ligaments are the main structures preventing an anterior dislocation of the knee in early foetal life; this deviation from the adult pattern is due to the bony configuration of the foetal knee. We therefore postulate that the basic defect in congenital dislocation of the knee is an absence or hypoplasia of the cruciate ligaments


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 6 | Pages 991 - 994
1 Nov 1999
Morgan-Jones RL Cross MJ

Thirty cruciate ligaments were retrieved from either cadavers or limbs which had been amputated. Each specimen was sectioned and stained to demonstrate the presence of collagen, nerves and vessels. All 30 specimens contained an interconnecting band of collagen fibres between the anterior and posterior cruciate ligaments. Vascular structures were present in all specimens and nerve fibres were identified in 26 (86%). We have called this structure the ‘intercruciate band’. The anterior and posterior cruciate ligaments should no longer be thought of in isolation, but together as a ‘cruciate complex’


Objectives. Posterior condylar offset (PCO) and posterior tibial slope (PTS) are critical factors in total knee arthroplasty (TKA). A computational simulation was performed to evaluate the biomechanical effect of PCO and PTS on cruciate retaining TKA. Methods. We generated a subject-specific computational model followed by the development of ± 1 mm, ± 2 mm and ± 3 mm PCO models in the posterior direction, and -3°, 0°, 3° and 6° PTS models with each of the PCO models. Using a validated finite element (FE) model, we investigated the influence of the changes in PCO and PTS on the contact stress in the patellar button and the forces on the posterior cruciate ligament (PCL), patellar tendon and quadriceps muscles under the deep knee-bend loading conditions. Results. Contact stress on the patellar button increased and decreased as PCO translated to the anterior and posterior directions, respectively. In addition, contact stress on the patellar button decreased as PTS increased. These trends were consistent in the FE models with altered PCO. Higher quadriceps muscle and patellar tendon force are required as PCO translated in the anterior direction with an equivalent flexion angle. However, as PTS increased, quadriceps muscle and patellar tendon force reduced in each PCO condition. The forces exerted on the PCL increased as PCO translated to the posterior direction and decreased as PTS increased. Conclusion. The change in PCO alternatively provided positive and negative biomechanical effects, but it led to a reduction in a negative biomechanical effect as PTS increased. Cite this article: K-T. Kang, Y-G. Koh, J. Son, O-R. Kwon, J-S. Lee, S. K. Kwon. A computational simulation study to determine the biomechanical influence of posterior condylar offset and tibial slope in cruciate retaining total knee arthroplasty. Bone Joint Res 2018;7:69–78. DOI: 10.1302/2046-3758.71.BJR-2017-0143.R1


Objectives. Preservation of both anterior and posterior cruciate ligaments in total knee arthroplasty (TKA) can lead to near-normal post-operative joint mechanics and improved knee function. We hypothesised that a patient-specific bicruciate-retaining prosthesis preserves near-normal kinematics better than standard off-the-shelf posterior cruciate-retaining and bicruciate-retaining prostheses in TKA. Methods. We developed the validated models to evaluate the post-operative kinematics in patient-specific bicruciate-retaining, standard off-the-shelf bicruciate-retaining and posterior cruciate-retaining TKA under gait and deep knee bend loading conditions using numerical simulation. Results. Tibial posterior translation and internal rotation in patient-specific bicruciate-retaining prostheses preserved near-normal kinematics better than other standard off-the-shelf prostheses under gait loading conditions. Differences from normal kinematics were minimised for femoral rollback and internal-external rotation in patient-specific bicruciate-retaining, followed by standard off-the-shelf bicruciate-retaining and posterior cruciate-retaining TKA under deep knee bend loading conditions. Moreover, the standard off-the-shelf posterior cruciate-retaining TKA in this study showed the most abnormal performance in kinematics under gait and deep knee bend loading conditions, whereas patient-specific bicruciate-retaining TKA led to near-normal kinematics. Conclusion. This study showed that restoration of the normal geometry of the knee joint in patient-specific bicruciate-retaining TKA and preservation of the anterior cruciate ligament can lead to improvement in kinematics compared with the standard off-the-shelf posterior cruciate-retaining and bicruciate-retaining TKA. Cite this article: Y-G. Koh, J. Son, S-K. Kwon, H-J. Kim, O-R. Kwon, K-T. Kang. Preservation of kinematics with posterior cruciate-, bicruciate- and patient-specific bicruciate-retaining prostheses in total knee arthroplasty by using computational simulation with normal knee model. Bone Joint Res 2017;6:557–565. DOI: 10.1302/2046-3758.69.BJR-2016-0250.R1


Bone & Joint Research
Vol. 6, Issue 1 | Pages 31 - 42
1 Jan 2017
Kang K Koh Y Jung M Nam J Son J Lee Y Kim S Kim S

Objectives. The aim of the current study was to analyse the effects of posterior cruciate ligament (PCL) deficiency on forces of the posterolateral corner structure and on tibiofemoral (TF) and patellofemoral (PF) contact force under dynamic-loading conditions. Methods. A subject-specific knee model was validated using a passive flexion experiment, electromyography data, muscle activation, and previous experimental studies. The simulation was performed on the musculoskeletal models with and without PCL deficiency using a novel force-dependent kinematics method under gait- and squat-loading conditions, followed by probabilistic analysis for material uncertain to be considered. Results. Comparison of predicted passive flexion, posterior drawer kinematics and muscle activation with experimental measurements showed good agreement. Forces of the posterolateral corner structure, and TF and PF contact forces increased with PCL deficiency under gait- and squat-loading conditions. The rate of increase in PF contact force was the greatest during the squat-loading condition. The TF contact forces increased on both medial and lateral compartments during gait-loading conditions. However, during the squat-loading condition, the medial TF contact force tended to increase, while the lateral TF contact forces decreased. The posterolateral corner structure, which showed the greatest increase in force with deficiency of PCL under both gait- and squat-loading conditions, was the popliteus tendon (PT). Conclusion. PCL deficiency is a factor affecting the variability of force on the PT in dynamic-loading conditions, and it could lead to degeneration of the PF joint. Cite this article: K-T. Kang, Y-G. Koh, M. Jung, J-H. Nam, J. Son, Y.H. Lee, S-J. Kim, S-H. Kim. The effects of posterior cruciate ligament deficiency on posterolateral corner structures under gait- and squat-loading conditions: A computational knee model. Bone Joint Res 2017;6:31–42. DOI: 10.1302/2046-3758.61.BJR-2016-0184.R1


The Bone & Joint Journal
Vol. 99-B, Issue 6 | Pages 774 - 778
1 Jun 2017
Agolley D Gabr A Benjamin-Laing H Haddad FS

Aims. The aim of this study was to report the outcome of the non-operative treatment of high-grade posterior cruciate ligament (PCL) injuries, particularly Hughston grade III injuries, which have not previously been described. Patients and Methods. This was a prospective study involving 46 consecutive patients who were athletes with MRI-confirmed isolated PCL injuries presenting within four weeks of injury. All had Hughston grade II (25 athletes) or III (21 athletes) injuries. Our non-operative treatment regimen involved initial bracing, followed by an individualised rehabilitation programme determined by the symptoms and physical signs. The patients were reviewed until they had returned to sports-specific training, and were reviewed again at a mean of 5.2 years (3 to 9). Results. The mean time to return to sports-specific training was 10.6 weeks and the mean time to return to full competitive sport was 16.4 weeks (10 to 40). A total of 42 patients (91.3%) were playing at the same or higher level of sport two years after the injury, with a mean Tegner activity score of 9 (5 to 10). At five years, 32 patients (69.5%) were playing at the same or higher level of sport, and 38 patients (82.6%) were playing at a competitive level, with a mean Tegner activity score of 9 (5 to 10). Conclusions. Medium-term review of a series of athletes suggests that commencing the non-operative management of isolated, Hughston grade II and III PCL injuries within four weeks of injury gives excellent functional outcomes with a high proportion returning to the same or higher level of sport. Cite this article: Bone Joint J 2017;99-B:774–8


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 6 | Pages 766 - 771
1 Jun 2007
Shannon FJ Cronin JJ Cleary MS Eustace SJ O’Byrne JM

Our aims were to map the tibial footprint of the posterior cruciate ligament (PCL) using MRI in patients undergoing PCL-preserving total knee replacement, and to document the disruption of this footprint as a result of the tibial cut. In 26 consecutive patients plain radiography and MRI of the knee were performed pre-operatively, and plain radiography post-operatively. The lower margin of the PCL footprint was located a mean of 1 mm (−10 to 8) above the upper aspect of the fibular head. The mean surface area was 83 mm. 2. (49 to 142). One-third of patients (8 of 22) had tibial cuts made below the lowest aspect of the PCL footprint (complete removal) and one-third (9 of 22) had cuts extending into the footprint (partial removal). The remaining patients (5 of 22) had footprints unaffected by the cuts, keeping them intact. Our study highlights the wide variation in the location of the tibial PCL footprint when referenced against the fibula. Proximal tibial cuts using conventional jigs resulted in the removal of a significant portion, if not all of the PCL footprint in most of the patients in our study. Our findings suggest that when performing PCL-retaining total knee replacement the tibial attachment of the PCL is often removed


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 129 - 132
1 Nov 2013
Berend KR Lombardi Jr AV Adams JB

Debate has raged over whether a cruciate retaining (CR) or a posterior stabilised (PS) total knee replacement (TKR) provides a better range of movement (ROM) for patients. Various sub-sets of CR design are frequently lumped together when comparing outcomes. Additionally, multiple factors have been proven to influence the rate of manipulation under anaesthetic (MUA) following TKR. The purpose of this study was to determine whether different CR bearing insert designs provide better ROM or different MUA rates. All primary TKRs performed by two surgeons between March 2006 and March 2009 were reviewed and 2449 CR-TKRs were identified. The same CR femoral component, instrumentation, and tibial base plate were consistently used. In 1334 TKRs a CR tibial insert with 3° posterior slope and no posterior lip was used (CR-S). In 803 there was an insert with no slope and a small posterior lip (CR-L) and in 312 knees the posterior cruciate ligament (PCL) was either resected or lax and a deep-dish, anterior stabilised insert was used (CR-AS). More CR-AS inserts were used in patients with less pre-operative ROM and greater pre-operative tibiofemoral deformity and flexion contracture (p < 0.05). The mean improvement in ROM was highest for the CR-AS inserts (5.9° (-40° to 55°) vs CR-S 3.1° (-45° to 70°) vs CR-L 3.0° (-45° to 65°); p = 0.004). There was a significantly higher MUA rate with the CR-S and CR-L inserts than CR-AS (Pearson rank 6.51; p = 0.04). Despite sacrificing or not substituting for the PCL, ROM improvement was highest, and the MUA rate was lowest in TKRs with a deep-dish, anterior-stabilised insert. Substitution for the posterior cruciate ligament (PCL) in the form of a PS design may not be necessary even when the PCL is deficient. . Cite this article: Bone Joint J 2013;95-B, Supple A:129–32


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 1 | Pages 117 - 120
1 Jan 1986
Soudry M Lanir A Angel D Roffman M Kaplan N Mendes D

Nuclear magnetic resonance imaging (MRI) was used to study the normal knee. As well as revealing bone quality, MRI provided useful information on intra-articular and extra-articular soft tissues. Midsagittal views gave clear images of the cruciate ligaments, and of the patellar and quadriceps tendons. Parasagittal views were the best for delineating the menisci which, like ligaments and tendons, are of low intensity; the semimembranosus tendon and its insertion to the proximal tibia were also seen clearly in these views. The cruciate ligaments and menisci, though visible in the coronal view also, were better seen in the sagittal view. Axial views provided information on the structure of the patella, its cartilage, the patellofemoral joint and posterior soft-tissue structures