The aim of this study was to give estimates of the incidence of component incompatibility in hip and knee arthroplasty and to test the effect of an online, real-time compatibility check. Intraoperative barcode registration of arthroplasty implants was introduced in Denmark in 2013. We developed a compatibility database and, from May 2017, real-time compatibility checking was implemented and became part of the registration. We defined four classes of component incompatibility: A-I, A-II, B-I, and B-II, depending on an assessment of the level of risk to the patient (A/B), and on whether incompatibility was knowingly accepted (I/II).Aims
Materials and Methods
We followed 138 patients (145 hips) who had had uncemented total hip arthroplasty using the Taperloc femoral component for a mean of ten years (8 to 12.5). No patient was lost to follow-up; 31 (31 hips) died before the minimum time of eight years for inclusion in the study, and 30 of these still had their femoral component in place. One well-fixed prosthesis had been exchanged at the time of acetabular revision. Of the remaining 114 hips, one femoral component required revision for aseptic loosening and one for sepsis. Three other well-fixed femoral components were removed during acetabular revision. Complete clinical and radiological follow-up was obtained in the 109 hips which had not had revision. Clinically, 94 (87%) were rated good or excellent, eight (7%) fair and seven (6%) poor. The average Harris hip score increased from 48 before operation to 88 at the time of the last follow-up. Radiologically, 103 hips (94%) had fixation by bone ingrowth, three (3%) showed stable fibrous ingrowth and three (3%) were
Older patients with multiple medical co-morbidities
are increasingly being offered and undergoing total joint arthroplasty
(TJA). These patients are more likely to require intensive care
support, following surgery. We prospectively evaluated the need
for intensive care admission and intervention in a consecutive series
of 738 patients undergoing elective hip and knee arthroplasty procedures.
The mean age was 60.6 years (18 to 91; 440 women, 298 men. Risk
factors, correlating with the need for critical care intervention,
according to published guidelines, were analysed to identify high-risk
patients who would benefit from post-operative critical care monitoring.
A total of 50 patients (6.7%) in our series required critical care
level interventions during their hospital stay. Six independent
multivariate clinical predictors were identified (p <
0.001)
including a history of congestive heart failure (odds ratio (OR)
24.26, 95% confidence interval (CI) 9.51 to 61.91), estimated blood
loss >
1000 mL (OR 17.36, 95% CI 5.36 to 56.19), chronic obstructive
pulmonary disease (13.90, 95% CI 4.78 to 40.36), intra-operative
use of vasopressors (OR 8.10, 95% CI 3.23 to 20.27), revision hip
arthroplasty (OR 2.71, 95% CI 1.04 to 7.04) and body mass index
>
35 kg/m2 (OR 2.70, 95% CI 123 to 5.94). The model was
then validated against an independent, previously published data
set of 1594 consecutive patients. The use of this risk stratification
model can be helpful in predicting which high-risk patients would
benefit from a higher level of monitoring and care after elective
TJA and aid hospitals in allocating precious critical care resources. Cite this article:
The Oxford hip and knee scores (OHS and OKS)
are validated patient-reported outcome measures used in patients undergoing
total hip replacement (THR), hip resurfacing (HR), total knee replacement
(TKR) and unicompartmental knee replacement (UKR). We analysed the
absolute OHS and OKS and change in scores following THR, HR, TKR,
and UKR performed at one specialist centre. All patients undergoing
and completing at least one Oxford score were eligible for inclusion
in the study which included 27 950 OHS and 19 750 OKS in 13 682
patients. Data were analysed using non-linear quantile regression.
The median absolute Oxford scores for THR, HR, TKR and UKR were
pre-operative 68.8% (15.0/48), 58.3% (20.0/48), 66.7% (16.0/48),
60.4% (19.0/48) respectively: and post-operative asymptote was 14.6%
(41.0/48), 5.8% (45.2/48), 31.2% (33.0/48), 29.2% (34.0/48). The
median asymptotic change from the pre-operative score for THR, HR,
TKR and UKR were 47.9% (23.0/48), 47.9% (23.0/48), 33.3% (16.0/48)
and 32.4% (15.5/48), respectively. The median time at which no further
appreciable change in score was achieved post-operatively was 0.7
years for THR, 1.1 years for HR, 0.9 years for TKR and 1.1 years
for UKR. The curves produced from this analysis could be used to educate
patients, and to audit the performance of a surgeon and an institution.
The time to achieve a stable improvement in outcome varied between
different types of joint replacement, which may have implications
for the timing of post-operative review. Cite this article:
We reviewed the outcome of 69 uncemented, custom-made,
distal femoral endoprosthetic replacements performed in 69 patients
between 1994 and 2006. There were 31 women and 38 men with a mean
age at implantation of 16.5 years (5 to 37). All procedures were
performed for primary malignant bone tumours of the distal femur.
At a mean follow-up of 124.2 months (4 to 212), 53 patients were
alive, with one patient lost to follow-up. All nine implants (13.0%)
were revised due to aseptic loosening at a mean of 52 months (8
to 91); three implants (4.3%) were revised due to fracture of the
shaft of the prosthesis and three patients (4.3%) had a peri-prosthetic
fracture. Bone remodelling associated with periosteal cortical thinning
adjacent to the uncemented intramedullary stem was seen in 24 patients
but this did not predispose to failure. All aseptically loose implants
in this series were diagnosed to be loose within the first five
years. The results from this study suggest that custom-made uncemented
distal femur replacements have a higher rate of aseptic loosening
compared to published results for this design when used with cemented
fixation. Loosening of uncemented replacements occurs early indicating
that initial fixation of the implant is crucial. Cite this article:
Using general practitioner records and hospital
notes and through direct telephone conversation with patients, we investigated
the accuracy of nine patient-reported complications gathered from
a self-completed questionnaire after elective joint replacement
surgery of the hip and knee. A total of 402 post-discharge complications
were reported after 8546 elective operations that were undertaken
within a three-year period. These were reported by 136 men and 240
women with a mean age of 71.8 years (34 to 93). A total of 319 reported
complications (79.4%; 95% confidence interval 75.4 to 83.3) were
confirmed to be correct. High rates of correct reporting were demonstrated
for infection (94.5%) and the need for further surgery (100%), whereas
the rates of reporting deep-vein thrombosis (DVT), pulmonary embolism,
myocardial infarction and stroke were lower (75% to 84.2%). Dislocation,
peri-prosthetic fractures and nerve palsy had modest rates of correct
reporting (36% to 57.1%). More patients who had knee surgery delivered
incorrect reports of dislocation (p = 0.001) and DVT (p = 0.013). Despite these variations, it appears that post-operative complications
may form part of a larger patient-reported outcome programme after
elective joint replacement surgery.
This prospective study evaluates the role of new laboratory markers in the diagnosis of deep implant infection in 78 patients (41 men and 37 women) with a revision total knee or hip replacement. The mean age at the time of operation was 64.0 years (19 to 90). Intra-operative cultures showed that 21 patients had a septic and 57 an aseptic total joint replacement. The white blood cell count, the erythrocyte sedimentation rate and levels of C-reactive protein, interleukin-6, procalcitonin and tumour necrosis factor (TNF)-α were measured in blood samples before operation. The diagnostic cut-off values were determined by Received Operating Characteristic curve analysis. C-reactive protein (>
3.2 md/dl) and interleukin-6 (>
12 pg/ml) have the highest sensitivity (0.95). Interleukin-6 is less specific than C-reactive protein (0.87 The combination of C-reactive protein and interleukin-6 measurement provide excellent screening tests for infection of a deep implant. A highly specific marker such as procalcitonin and pre-operative aspiration of the joint might be useful in identifying patients with true positive C-reactive protein and/or interleukin-6 levels.
We randomised 120 patients who were undergoing either primary total hip or knee arthroplasty to receive either ferrous sulphate or a placebo for three weeks after surgery. The level of haemoglobin and absolute reticulocyte count were measured at one and five days, and three and six weeks after operation. Ninety-nine patients (ferrous sulphate 50, placebo 49) completed the study. The two groups differed only in the treatment administered. Recovery of level of haemoglobin was similar at five days and three weeks and returned to 85% of the pre-operative level, irrespective of the treatment group. A small, albeit greater recovery in the level of haemoglobin was identified at six weeks in the ferrous sulphate group in both men (ferrous sulphate 5%, placebo 1.5%) and women (ferrous sulphate 6%, placebo 3%). The clinical significance of this is questionable and may be outweighed by the high incidence of reported side effects of oral iron and the cost of the medication. Administration of iron supplements after elective total hip or total knee arthroplasty does not appear to be worthwhile.