header advert
Results 1 - 20 of 24
Results per page:
The Bone & Joint Journal
Vol. 96-B, Issue 6 | Pages 783 - 788
1 Jun 2014
Kanakaris N Gudipati S Tosounidis T Harwood P Britten S Giannoudis PV

Intramedullary infection in long bones represents a complex clinical challenge, with an increasing incidence due to the increasing use of intramedullary fixation. We report a prospective case series using an intramedullary reaming device, the Reamer–Irrigator–Aspirator (RIA) system, in association with antibiotic cement rods for the treatment of lower limb long bone infections. A total of 24 such patients, 16 men and eight women, with a mean age of 44.5 years (17 to 75), 14 with femoral and 10 with tibial infection, were treated in a staged manner over a period of 2.5 years in a single referral centre. Of these, 21 patients had had previous surgery, usually for fixation of a fracture (seven had sustained an open fracture originally and one had undergone fasciotomies). According to the Cierny–Mader classification system, 18 patients were classified as type 1A, four as 3A (discharging sinus tract), one as type 4A and one as type 1B. Staphylococcus species were isolated in 20 patients (83.3%). Local antibiotic delivery was used in the form of impregnated cement rods in 23 patients. These were removed at a mean of 2.6 months (1 to 5). Pathogen-specific antibiotics were administered systemically for a mean of six weeks (3 to 18). At a mean follow-up of 21 months (8 to 36), 23 patients (96%) had no evidence of recurrent infection. One underwent a planned trans-tibial amputation two weeks post-operatively due to peripheral vascular disease and chronic recalcitrant osteomyelitis of the tibia and foot. The combination of RIA reaming, the administration of systemic pathogen-specific antibiotics and local delivery using impregnated cement rods proved to be a safe and efficient form of treatment in these patients. Cite this article: Bone Joint J 2014; 96-B:783–8


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 5 | Pages 644 - 649
1 May 2011
Yonekura Y Miyamoto H Shimazaki T Ando Y Noda I Mawatari M Hotokebuchi T

A silver-containing hydroxyapatite (Ag-HA) coating has been developed using thermal spraying technology. We evaluated the osteoconductivity of this coating on titanium (Ti) implants in rat tibiae in relation to bacterial infection in joint replacement.

At 12 weeks, the mean affinity indices of bone formation of a Ti, an HA, a 3%Ag-HA and a 50%Ag-HA coating were 97.3%, 84.9%, 81.0% and 40.5%, respectively. The mean affinity indices of bone contact of these four coatings were 18.8%, 83.7%, 77.2% and 40.5%, respectively. The indices of bone formation and bone contact around the implant of the 3%Ag-HA coating were similar to those of the HA coating, and no significant differences were found between them (bone formation, p = 0.99; bone contact, p = 0.957). However, inhibition of bone formation was observed with the 50%Ag-HA coating.

These results indicate that the 3%Ag-HA coating has low toxicity and good osteoconductivity, and that the effect of silver toxicity on osteoconductivity depends on the dose.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 5 | Pages 668 - 671
1 May 2005
Lee PTH Clarke MT Bearcroft PWP Robinson AHN

We have assessed the proximal capsular extension of the ankle joint in 18 patients who had a contrast-enhanced MRI ankle arthrogram in order to delineate the capsular attachments. We noted consistent proximal capsular extensions anterior to the distal tibia and in the tibiofibular recess. The mean capsular extension anterior to the distal tibia was 9.6 mm (4.9 to 27.0) proximal to the anteroinferior tibial margin and 3.8 mm (−2.1 to 9.3) proximal to the dome of the tibial plafond. In the tibiofibular recess, the mean capsular extension was 19.2 mm (12.7 to 38.0) proximal to the anteroinferior tibial margin and 13.4 mm (5.8 to 20.5) proximal to the dome of the tibial plafond. These areas of proximal capsular extensions run the risk of being traversed during the insertion of finewires for the treatment of fractures of the distal tibia. Surgeons using these techniques should be aware of this anatomy in order to minimise the risk of septic arthritis


Bone & Joint Research
Vol. 5, Issue 3 | Pages 101 - 105
1 Mar 2016
Wang X Luo F Huang K Xie Z

Objectives. Induced membrane technique is a relatively new technique in the reconstruction of large bone defects. It involves the implantation of polymethylmethacrylate (PMMA) cement in the bone defects to induce the formation of membranes after radical debridement and reconstruction of bone defects using an autologous cancellous bone graft in a span of four to eight weeks. The purpose of this study was to explore the clinical outcomes of the induced membrane technique for the treatment of post-traumatic osteomyelitis in 32 patients. Methods. A total of 32 cases of post-traumatic osteomyelitis were admitted to our department between August 2011 and October 2012. This retrospective study included 22 men and ten women, with a mean age of 40 years (19 to 70). Within this group there were 20 tibias and 12 femurs with a mean defect of 5 cm (1.5 to 12.5). Antibiotic-loaded PMMA cement was inserted into the defects after radical debridement. After approximately eight weeks, the defects were implanted with bone graft. Results. The patients were followed for 27.5 months (24 to 32). Radiographic bone union occurred at six months for 26 cases (81%) and clinical healing occurred in 29 cases (90%) at ten months. A total of six cases had a second debridement before bone grafting because of recurrence of infection and one patient required a third debridement. No cases of osteomyelitis had recurred at the time of the last follow-up visit. Conclusion. The induced membrane technique for the treatment of post-traumatic osteomyelitis is a simple, reliable method, with good early results. However, there are many challenges in determining the scope of the debridement, type of limb fixation and source of bone graft to be used. Cite this article: Dr Z. Xie. Induced membrane technique for the treatment of bone defects due to post-traumatic osteomyelitis. Bone Joint Res 2016;5:101–105. DOI: 10.1302/2046-3758.53.2000487


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 1 | Pages 75 - 79
1 Jan 2012
Herscovici, Jr D Scaduto JM

The use of autograft bone is the best option when undertaking a procedure that requires bone graft because it is osteogenic, osteoconductive and osseo-inductive. Pain, morbidity and complications associated with harvesting iliac or non-iliac sites occur in between 6% and 30% of cases. An alternative source of graft with possibly a lower morbidity is the intramedullary canal. In this study, 28 patients undergoing 30 arthrodesis procedures on the hindfoot had a mean of 48 cm. 3 . (43 to 50) of bone harvested locally from the hindfoot or the tibial shaft by antegrade or retrograde reaming. No patient sustained a fracture of the calcaneum, talus or tibia. There was no morbidity except for one complication when the reamer breached the medial tibial cortex. This healed uneventfully. . This method of using the reamer–irrigator–aspirator system is an extension of the standard technique of intramedullary reaming of the lower limb: it produces good-quality bone graft with viable growth factors consistent with that of the iliac crest, and donor site morbidity is low. This is an efficient method of obtaining autologous bone for use in arthrodesis of the ankle or hindfoot


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 7 | Pages 1022 - 1025
1 Sep 2000
Minami A Kasashima T Iwasaki N Kato H Kaneda K

The results and complications of 104 vascularised fibular grafts in 102 patients are presented. Bony union was ultimately achieved in 97 patients, with primary union in 84 (84%). The mean time to union was 15.5 weeks (8 to 40). In 13 patients, primary union was achieved at one end of the fibula and secondary union at the other end. In these patients, the mean time to union was 31.1 weeks (24 to 40). Five patients failed to achieve union, with a resultant pseudarthrosis (3 patients) or amputation (2 patients). There were various complications. Immediate thrombosis occurred in 14 cases. In two of 23 patients with osteomyelitis, infection recurred at two and six months after surgery, respectively. Both patients had active osteomyelitis less than one month before the operation. Bony infection occurred in a patient with a synovial sarcoma of the forearm one year after surgery. In 15 patients, 19 fractures of the fibular graft occurred after bony union, all except one within one year after union. In patients in whom an external fixator had been used, fracture occurred soon after its removal. Union was difficult to achieve in cases of congenital pseudarthrosis of the tibia. Appropriate alignment of the fibular graft is an important factor in preventing stress fracture. The vascularised fibula should be protected during the first year after union. Postoperative complications at the donor site included transient palsy of the superficial peroneal nerve in three patients, contracture of flexor hallucis longus in two and valgus deformity of the ankle in three. Vascularised fibular grafts are useful in the reconstruction of massive bony defects. We believe that meticulous preoperative planning, including choosing which vessels to select in the recipient and the type of fixation devices to use, and care in the introduction of the vascularised fibula, can improve the results and prevent complications


The Bone & Joint Journal
Vol. 98-B, Issue 10 | Pages 1382 - 1388
1 Oct 2016
Laubscher M Mitchell C Timms A Goodier D Calder P

Aims

Patients undergoing femoral lengthening by external fixation tolerate treatment less well when compared to tibial lengthening. Lengthening of the femur with an intramedullary device may have advantages.

Patients and Methods

We reviewed all cases of simple femoral lengthening performed at our unit from 2009 to 2014. Cases of nonunions, concurrent deformities, congenital limb deficiencies and lengthening with an unstable hip were excluded, leaving 33 cases (in 22 patients; 11 patients had bilateral procedures) for review. Healing index, implant tolerance and complications were compared.


The Bone & Joint Journal
Vol. 95-B, Issue 12 | Pages 1667 - 1672
1 Dec 2013
Oh C Apivatthakakul T Oh J Kim J Lee H Kyung H Baek S Jung G

Although gradual bone transport may permit the restoration of large-diameter bones, complications are common owing to the long duration of external fixation. In order to reduce such complications, a new technique of bone transport involving the use of an external fixator and a locking plate was devised for segmental tibial bone defects.

A total of ten patients (nine men, one woman) with a mean age at operation of 40.4 years (16 to 64) underwent distraction osteogenesis with a locking plate to treat previously infected post-traumatic segmental tibial defects. The locking plate was fixed percutaneously to bridge proximal and distal segments, and was followed by external fixation. After docking, percutaneous screws were fixed at the transported segment through plate holes. At the same time, bone grafting was performed at the docking site with the external fixator removed.

The mean defect size was 5.9 cm (3.8 to 9.3) and mean external fixation index was 13.4 days/cm (11.8 to 19.5). In all cases, primary union of the docking site and distraction callus was achieved, with an excellent bony result. There was no recurrence of deep infection or osteomyelitis, and with the exception of one patient with a pre-existing peroneal nerve injury, all achieved an excellent or good functional result.

With short external fixation times and low complication rates, bone transport with a locking plate could be recommended for patients with segmental tibial defects.

Cite this article: Bone Joint J 2013;95-B:1667–72.


The Bone & Joint Journal
Vol. 97-B, Issue 6 | Pages 814 - 817
1 Jun 2015
Bose D Kugan R Stubbs D McNally M

Infected nonunion of a long bone continues to present difficulties in management. In addition to treating the infection, it is necessary to establish bony stability, encourage fracture union and reconstruct the soft-tissue envelope.

We present a series of 67 infected nonunions of a long bone in 66 patients treated in a multidisciplinary unit. The operative treatment of patients suitable for limb salvage was performed as a single procedure. Antibiotic regimes were determined by the results of microbiological culture.

At a mean follow-up of 52 months (22 to 97), 59 patients (88%) had an infection-free united fracture in a functioning limb. Seven others required amputation (three as primary treatment, three after late failure of limb salvage and one for recalcitrant pain after union).

The initial operation achieved union in 54 (84%) of the salvaged limbs at a mean of nine months (three to 26), with recurrence of infection in 9%. Further surgery in those limbs that remained ununited increased the union rate to 62 (97%) of the 64 limbs treated by limb salvage at final follow-up. The use of internal fixation was associated with a higher risk of recurrent infection than external fixation.

Cite this article: Bone Joint J 2015; 97-B:814–17.


The Bone & Joint Journal
Vol. 96-B, Issue 10 | Pages 1349 - 1354
1 Oct 2014
Conway J Mansour J Kotze K Specht S Shabtai L

The treatment of infected nonunions is difficult. Antibiotic cement-coated (ACC) rods provide stability as well as delivering antibiotics. We conducted a review of 110 infected nonunions treated with ACC rods. Patients were divided into two groups: group A (67 patients) with an infected arthrodesis, and group B (43 patients) with an infected nonunion in a long bone. In group A, infected arthrodesis, the success rate after the first procedure was 38/67 (57%), 29/67 (43%) required further surgery for either control of infection or non-union. At last follow-up, five patients required amputation, representing a limb salvage rate of 62/67 (93%) overall. In all, 29/67 (43%) presented with a bone defect with a mean size of 6.78 cm (2 to 25). Of those with a bone defect, 13/29 (45%) required further surgery and had a mean size of defect of 7.2 cm (3.5 to 25). The cultures were negative in 17/67 (26%) and the most common organism cultured was methicillin-resistant staphylococcus aureus (MRSA) (23/67, (35%)). In group B, long bones nonunion, the success rate after the first procedure was 26/43 (60%), 17/43 (40%) required further surgery for either control of infection or nonunion. The limb salvage rate at last follow-up was 43/43 (100%). A total of 22/43 (51%) had bone defect with a mean size of 4.7 cm (1.5 to 11.5). Of those patients with a bone defect, 93% required further surgery with a mean size of defect of 5.4 cm (3 to 8.5). The cultures were negative in 10/43 (24%) and the most common organism cultured was MRSA, 15/43 (35%). ACC rods are an effective form of treatment for an infected nonunion, with an acceptable rate of complications.

Cite this article: Bone Joint J 2014; 96-B:1349–54


The Bone & Joint Journal
Vol. 95-B, Issue 12 | Pages 1673 - 1680
1 Dec 2013
Papakostidis C Bhandari M Giannoudis PV

We carried out a systematic review of the literature to evaluate the evidence regarding the clinical results of the Ilizarov method in the treatment of long bone defects of the lower limbs.

Only 37 reports (three non-randomised comparative studies, one prospective study and 33 case-series) met our inclusion criteria. Although several studies were unsatisfactory in terms of statistical heterogeneity, our analysis appears to show that the Ilizarov method of distraction osteogenesis significantly reduced the risk of deep infection in infected osseous lesions (risk ratio 0.14 (95% confidence interval (CI) 0.10 to 0.20), p < 0.001). However, there was a rate of re-fracture of 5% (95% CI 3 to 7), with a rate of neurovascular complications of 2.2% (95% CI 0.3 to 4) and an amputation rate of 2.9% (95% CI 1.4 to 4.4).The data was generally not statistically heterogeneous. Where tibial defects were > 8 cm, the risk of re-fracture increased (odds ratio 3.7 (95% CI 1.1 to 12.5), p = 0.036).

The technique is demanding for patients, illustrated by the voluntary amputation rate of 1.6% (95% CI 0 to 3.1), which underlines the need for careful patient selection.

Cite this article: Bone Joint J 2013;95-B:1673–80.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 782 - 787
1 Jun 2011
Sun X Easwar TR Manesh S Ryu J Song S Kim S Song H

We compared the complications and outcome of tibial lengthening using the Ilizarov method with and without the use of a supplementary intramedullary nail. In a retrospective case-matched series assembled from 176 patients with tibial lengthening, we matched 52 patients (26 pairs, group A with nail and group B without) according to the following criteria in order of importance: 1) difference in amount of lengthening (± 2 cm); 2) percentage difference in lengthening (± 5%); 3) difference in patient’s age (± seven years); 4) aetiology of the shortening, and 5) level of difficulty in obtaining the correction. The outcome was evaluated using the external fixator index, the healing index and an outcome score according to the criteria of Paley. It was found that some complications were specific to group A or B respectively, but others were common to both groups.

The outcome was generally better in lengthenings with a nail, although there was a higher incidence of rectifiable equinus deformity in these patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 788 - 792
1 Jun 2011
Schiedel FM Pip S Wacker S Pöpping J Tretow H Leidinger B Rödl R

We report the results of intramedullary leg lengthening conducted between 2002 and 2009 using the Intramedullary Skeletal Kinetic Distractor in 69 unilateral lengthenings involving 58 femora and 11 tibiae. We identified difficulties that occurred during the treatment and assessed whether they were specifically due to the implant or independent of it. Paley’s classification for evaluating problems, obstacles and complications with external fixators was adopted, and implant-specific difficulties were continuously noted. There were seven failures requiring premature removal of the device, in four due to nail breakage and three for other reasons, and five unsuccessful outcomes after completion of the lengthening. In all, 116 difficulties were noted in 45 patients, with only 24 having problem-free courses. In addition to the difficulties arising from the use of external fixators, there were almost the same number again of implant-specific difficulties.

Nevertheless, successful femoral lengthening was achieved in 52 of the 58 patients (90%). However, successful tibial lengthening was only achieved in five of 11 patients (45%).


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 5 | Pages 639 - 643
1 May 2011
Burghardt RD Herzenberg JE Specht SC Paley D

Between October 2001 and September 2009 we lengthened 242 lower-limb segments in 180 patients using the Intramedullary Skeletal Kinetic Distractor (ISKD). Mechanical failure was defined either as breakage of the ISKD or failure of the internal mechanism to activate. Retrieved nails which failed mechanically were examined by the manufacturer for defects. In all, 15 ISKDs in 12 patients (13 limbs) failed mechanically representing an overall failure rate of 6.2%, with fracture of the device occurring in ten of the 15 failures. Two nails in one patient failed to lengthen and had to be replaced. The manufacturer detected an error in the assembly of the nail, which prompted a wide recall. One nail jammed after being forcefully inserted, and two nails failed to lengthen fully. Lengthening was achieved in all 12 patients, although three required a second operation to exchange a defective nail for a new, functioning device.

The ISKD is a complex mechanical device which lengthens by the oscillation of two telescopic sections connected by a threaded rod. The junction between these sections is surrounded by a keyring collar. This keyring collar is the weakest part of the device.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 1 | Pages 52 - 56
1 Jan 2011
Kocaoglu M Bilen FE Sen C Eralp L Balci HI

We present the results of the surgical correction of lower-limb deformities caused by metabolic bone disease. Our series consisted of 17 patients with a diagnosis of hypophosphataemic rickets and two with renal osteodystrophy; their mean age was 25.6 years (14 to 57). In all, 43 lower-limb segments (27 femora and 16 tibiae) were osteotomised and the deformity corrected using a monolateral external fixator. The segment was then stabilised with locked intramedullary nailing. In addition, six femora in three patients were subsequently lengthened by distraction osteogenesis. The mean follow-up was 60 months (18 to 120). The frontal alignment parameters (the mechanical axis deviation, the lateral distal femoral angle and the medial proximal tibial angle) and the sagittal alignment parameters (the posterior distal femoral angle and the posterior proximal tibial angle) improved post-operatively. The external fixator was removed either at the end of surgery or at the end of the lengthening period, allowing for early mobilisation and weight-bearing. We encountered five problems and four obstacles in the programme of treatment.

The use of intramedullary nails prevented recurrence of deformity and refracture.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 9 | Pages 1234 - 1240
1 Sep 2012
Willcox NMJ Clarke JV Smith BRK Deakin AH Deep K

We compared lower limb coronal alignment measurements obtained pre- and post-operatively with long-leg radiographs and computer navigation in patients undergoing primary total knee replacement (TKR). A series of 185 patients had their pre- and post-implant radiological and computer-navigation system measurements of coronal alignment compared using the Bland-Altman method. The study included 81 men and 104 women with a mean age of 68.5 years (32 to 87) and a mean body mass index of 31.7 kg/m2 (19 to 49). Pre-implant Bland–Altman limits of agreement were -9.4° to 8.6° with a repeatability coefficient of 9.0°. The Bland–Altman plot showed a tendency for the radiological measurement to indicate a higher level of pre-operative deformity than the corresponding navigation measurement. Post-implant limits of agreement were -5.0° to 5.4° with a repeatability coefficient of 5.2°. The tendency for valgus knees to have greater deformity on the radiograph was still seen, but was weaker for varus knees.

The alignment seen or measured intra-operatively during TKR is not necessarily the same as the deformity seen on a standing long-leg radiograph either pre- or post-operatively. Further investigation into the effect of weight-bearing and surgical exposure of the joint on the mechanical femorotibial angle is required to enable the most appropriate intra-operative alignment to be selected.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 3 | Pages 343 - 347
1 Mar 2005
Winson IG Robinson DE Allen PE

We reviewed 116 patients who underwent 118 arthroscopic ankle arthrodeses. The mean age at operation was 57 years, 2 months (20 to 86 years). The indication for operation was post-traumatic osteoarthritis in 67, primary osteoarthritis in 36, inflammatory arthropathy in 13 and avascular necrosis in two. The mean follow-up was 65 months (18 to 144). Nine patients (10 ankles) died before final review and three were lost to follow-up, leaving 104 patients (105 ankles) who were assessed by a standard telephone interview. The pre-operative talocrural deformity was between 22° valgus and 28° varus, 94 cases were within 10° varus/valgus. The mean time to union was 12 weeks (6 to 20). Nonunion occurred in nine cases (7.6%). Other complications included 22 cases requiring removal of a screw for prominence, three superficial infections, two deep vein thromboses/pulmonary emboli, one revision of fixation, one stress fracture and one deep infection. Six patients had a subtalar fusion at a mean of 48 months after ankle fusion. There were 48 patients with excellent, 35 with good, 10 with fair and 11 with poor clinical results.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 8 | Pages 1032 - 1038
1 Aug 2006
Hopgood P Kumar R Wood PLR

Between 1999 and 2005, 23 failed total ankle replacements were converted to arthrodeses. Three surgical techniques were used: tibiotalar arthrodesis with screw fixation, tibiotalocalcaneal arthrodesis with screw fixation, and tibiotalocalcaneal arthrodesis with an intramedullary nail. As experience was gained, the benefits and problems became apparent. Successful bony union was seen in 17 of the 23 ankles. The complication rate was higher in ankles where the loosening had caused extensive destruction of the body of the talus, usually in rheumatoid arthritis. In this situation we recommend tibiotalocalcaneal arthrodesis with an intramedullary nail. This technique can also be used when there is severe arthritic change in the subtalar joint. Arthrodesis of the tibiotalar joint alone using compression screws was generally possible in osteoarthritis because the destruction of the body of the talus was less extensive. Tibiotalocalcaneal arthrodesis fusion with compression screws has not been successful in our experience.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 6 | Pages 809 - 813
1 Jun 2005
Lemon M Somayaji HS Khaleel A Elliott DS

Fragility fractures of the ankle occur mainly in elderly osteoporotic women. They are inherently unstable and difficult to manage. There is a high incidence of complications with both non-operative and operative treatment.

We treated 12 such fractures by closed reduction and stabilisation using a retrograde calcaneotalotibial expandable nail. The mean age of patients was 84 years (75 to 95). All were women and were able to walk fully weight-bearing after surgery. There were no wound complications. One patient died from a myocardial infarction 24 days after surgery. The 11 other patients were followed up for a mean of 67 weeks (39 to 104).

All the fractures maintained satisfactory alignment and healed without delay. Six patients refused removal of the nail after union of the fracture. The functional rating using the scale of Olerud and Molander gave a mean score at follow-up of 61, compared with a pre-injury value of 70.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 7 | Pages 909 - 913
1 Jul 2006
Tanaka Y Takakura Y Hayashi K Taniguchi A Kumai T Sugimoto K

In this retrospective study we have assessed the results of low tibial valgus osteotomy for varus-type osteoarthritis of the ankle and its indications.

We performed an opening wedge osteotomy in 25 women (26 ankles). The mean follow-up was for eight years and three months (2 years 3 months to 17 years 11 months).

Of the 26 ankles, 19 showed excellent or good clinical results. Their mean scores for pain, walking, and activities of daily living were significantly improved but there was no change in the range of movement. In the ankles which were classified radiologically as stage 2 according to our own grading system, with narrowing of the medial joint space, and in 11 as stage 3a, with obliteration of the joint space at the medial malleolus only, the joint space recovered. In contrast, such recovery was seen in only two of 12 ankles classified as stage 3b, with obliteration of the joint space advancing to the upper surface of the dome of the talus. Low tibial osteotomy is indicated for varus-type osteoarthritis of stage 2 or stage 3a.