Results 1 - 20 of 1233
Results per page:
The Bone & Joint Journal
Vol. 105-B, Issue 5 | Pages 496 - 503
1 May 2023
Mills ES Talehakimi A Urness M Wang JC Piple AS Chung BC Tezuka T Heckmann ND

Aims. It has been well documented in the arthroplasty literature that lumbar degenerative disc disease (DDD) contributes to abnormal spinopelvic motion. However, the relationship between the severity or pattern of hip osteoarthritis (OA) as measured on an anteroposterior (AP) pelvic view and spinopelvic biomechanics has not been well investigated. Therefore, the aim of the study is to examine the association between the severity and pattern of hip OA and spinopelvic motion. Methods. A retrospective chart review was conducted to identify patients undergoing primary total hip arthroplasty (THA). Plain AP pelvic radiographs were reviewed to document the morphological characteristic of osteoarthritic hips. Lateral spine-pelvis-hip sitting and standing plain radiographs were used to measure sacral slope (SS) and pelvic femoral angle (PFA) in each position. Lumbar disc spaces were measured to determine the presence of DDD. The difference between sitting and standing SS and PFA were calculated to quantify spinopelvic motion (ΔSS) and hip motion (ΔPFA), respectively. Univariate analysis and Pearson correlation were used to identify morphological hip characteristics associated with changes in spinopelvic motion. Results. In total, 139 patients were included. Increased spinopelvic motion was observed in patients with loss of femoral head contour, cam deformity, and acetabular bone loss (all p < 0.05). Loss of hip motion was observed in patients with loss of femoral head contour, cam deformity, and acetabular bone loss (all p < 0.001). A decreased joint space was associated with a decreased ΔPFA (p = 0.040). The presence of disc space narrowing, disc space narrowing > two levels, and disc narrowing involving the L5–S1 segment were associated with decreased spinopelvic motion (all p < 0.05). Conclusion. Preoperative hip OA as assessed on an AP pelvic radiograph predicts spinopelvic motion. These data suggest that specific hip osteoarthritic morphological characteristics listed above alter spinopelvic motion to a greater extent than others. Cite this article: Bone Joint J 2023;105-B(5):496–503


The Bone & Joint Journal
Vol. 98-B, Issue 5 | Pages 634 - 640
1 May 2016
Pedowitz DI Kane JM Smith GM Saffel HL Comer C Raikin SM

Aims. Few reports compare the contribution of the talonavicular articulation to overall range of movement in the sagittal plane after total ankle arthroplasty (TAA) and tibiotalar arthrodesis. The purpose of this study was to assess changes in ROM and functional outcomes following tibiotalar arthrodesis and TAA. Patients and Methods. Patients who underwent isolated tibiotalar arthrodesis or TAA with greater than two-year follow-up were enrolled in the study. Overall arc of movement and talonavicular movement in the sagittal plane were assessed with weight-bearing lateral maximum dorsiflexion and plantarflexion radiographs. All patients completed Short Form-12 version 2.0 questionnaires, visual analogue scale for pain (VAS) scores, and the Foot and Ankle Ability Measure (FAAM). Results. In all, 41 patients who underwent TAA and 27 patients who underwent tibiotalar arthrodesis were enrolled in the study. The mean total arc of movement was 34.2° (17.0° to 59.1°) with an average contribution from the talonavicular joint of 10.5° (1.2° to 28.8°) in the TAA cohort. The average total arc of movement was 24.3° (6.9° to 44.3°) with a mean contribution from the talonavicular joint of 22.8° (5.6° to 41.4°) in the arthrodesis cohort. A statistically significant difference was detected for both total sagittal plane movement (p = 0.00025), and for talonavicular motion (p < 0.0001). A statistically significant lower VAS score (p = 0.0096) and higher FAAM (p = 0.01, p = 0.019, respectively) was also detected in the TAA group. Conclusion. TAA preserves more anatomical movement, has better pain relief and better patient-perceived post-operative function compared with patients undergoing fusion. The relative increase of talonavicular movement in fusion patients may play a role in the outcomes compared with TAA and may predispose these patients to degenerative changes over time. Take home message: TAA preserves more anatomic sagittal plane motion and provides greater pain relief and better patient-perceived outcomes compared with ankle arthrodesis. Cite this article: Bone Joint J 2016;98-B:634–40


Bone & Joint Research
Vol. 10, Issue 12 | Pages 780 - 789
1 Dec 2021
Eslam Pour A Lazennec JY Patel KP Anjaria MP Beaulé PE Schwarzkopf R

Aims. In computer simulations, the shape of the range of motion (ROM) of a stem with a cylindrical neck design will be a perfect cone. However, many modern stems have rectangular/oval-shaped necks. We hypothesized that the rectangular/oval stem neck will affect the shape of the ROM and the prosthetic impingement. Methods. Total hip arthroplasty (THA) motion while standing and sitting was simulated using a MATLAB model (one stem with a cylindrical neck and one stem with a rectangular neck). The primary predictor was the geometry of the neck (cylindrical vs rectangular) and the main outcome was the shape of ROM based on the prosthetic impingement between the neck and the liner. The secondary outcome was the difference in the ROM provided by each neck geometry and the effect of the pelvic tilt on this ROM. Multiple regression was used to analyze the data. Results. The stem with a rectangular neck has increased internal and external rotation with a quatrefoil cross-section compared to a cone in a cylindrical neck. Modification of the cup orientation and pelvic tilt affected the direction of projection of the cone or quatrefoil shape. The mean increase in internal rotation with a rectangular neck was 3.4° (0° to 7.9°; p < 0.001); for external rotation, it was 2.8° (0.5° to 7.8°; p < 0.001). Conclusion. Our study shows the importance of attention to femoral implant design for the assessment of prosthetic impingement. Any universal mathematical model or computer simulation that ignores each stem’s unique neck geometry will provide inaccurate predictions of prosthetic impingement. Cite this article: Bone Joint Res 2021;10(12):780–789


Bone & Joint Research
Vol. 12, Issue 5 | Pages 313 - 320
8 May 2023
Saiki Y Kabata T Ojima T Kajino Y Kubo N Tsuchiya H

Aims. We aimed to assess the reliability and validity of OpenPose, a posture estimation algorithm, for measurement of knee range of motion after total knee arthroplasty (TKA), in comparison to radiography and goniometry. Methods. In this prospective observational study, we analyzed 35 primary TKAs (24 patients) for knee osteoarthritis. We measured the knee angles in flexion and extension using OpenPose, radiography, and goniometry. We assessed the test-retest reliability of each method using intraclass correlation coefficient (1,1). We evaluated the ability to estimate other measurement values from the OpenPose value using linear regression analysis. We used intraclass correlation coefficients (2,1) and Bland–Altman analyses to evaluate the agreement and error between radiography and the other measurements. Results. OpenPose had excellent test-retest reliability (intraclass correlation coefficient (1,1) = 1.000). The R. 2. of all regression models indicated large correlations (0.747 to 0.927). In the flexion position, the intraclass correlation coefficients (2,1) of OpenPose indicated excellent agreement (0.953) with radiography. In the extension position, the intraclass correlation coefficients (2,1) indicated good agreement of OpenPose and radiography (0.815) and moderate agreement of goniometry with radiography (0.593). OpenPose had no systematic error in the flexion position, and a 2.3° fixed error in the extension position, compared to radiography. Conclusion. OpenPose is a reliable and valid tool for measuring flexion and extension positions after TKA. It has better accuracy than goniometry, especially in the extension position. Accurate measurement values can be obtained with low error, high reproducibility, and no contact, independent of the examiner’s skills. Cite this article: Bone Joint Res 2023;12(5):313–320


Aims. Total knee arthroplasty (TKA) may provoke ankle symptoms. The aim of this study was to validate the impact of the preoperative mechanical tibiofemoral angle (mTFA), the talar tilt (TT) on ankle symptoms after TKA, and assess changes in the range of motion (ROM) of the subtalar joint, foot posture, and ankle laxity. Methods. Patients who underwent TKA from September 2020 to September 2021 were prospectively included. Inclusion criteria were primary end-stage osteoarthritis (Kellgren-Lawrence stage IV) of the knee. Exclusion criteria were missed follow-up visit, post-traumatic pathologies of the foot, and neurological disorders. Radiological angles measured included the mTFA, hindfoot alignment view angle, and TT. The Foot Function Index (FFI) score was assessed. Gait analyses were conducted to measure mediolateral changes of the gait line and ankle laxity was tested using an ankle arthrometer. All parameters were acquired one week pre- and three months postoperatively. Results. A total of 69 patients (varus n = 45; valgus n = 24) underwent TKA and completed the postoperative follow-up visit. Of these, 16 patients (23.2%) reported the onset or progression of ankle symptoms. Varus patients with increased ankle symptoms after TKA had a significantly higher pre- and postoperative TT. Valgus patients with ankle symptoms after TKA showed a pathologically lateralized gait line which could not be corrected through TKA. Patients who reported increased ankle pain neither had a decreased ROM of the subtalar joint nor increased ankle laxity following TKA. The preoperative mTFA did not correlate with the postoperative FFI (r = 0.037; p = 0.759). Conclusion. Approximately one-quarter of the patients developed ankle pain after TKA. If patients complain about ankle symptoms after TKA, standing radiographs of the ankle and a gait analysis could help in detecting a malaligned TT or a pathological gait. Cite this article: Bone Joint J 2023;105-B(11):1159–1167


Bone & Joint Open
Vol. 2, Issue 10 | Pages 834 - 841
11 Oct 2021
O'Connor PB Thompson MT Esposito CI Poli N McGree J Donnelly T Donnelly W

Aims. Pelvic tilt (PT) can significantly change the functional orientation of the acetabular component and may differ markedly between patients undergoing total hip arthroplasty (THA). Patients with stiff spines who have little change in PT are considered at high risk for instability following THA. Femoral component position also contributes to the limits of impingement-free range of motion (ROM), but has been less studied. Little is known about the impact of combined anteversion on risk of impingement with changing pelvic position. Methods. We used a virtual hip ROM (vROM) tool to investigate whether there is an ideal functional combined anteversion for reduced risk of hip impingement. We collected PT information from functional lateral radiographs (standing and sitting) and a supine CT scan, which was then input into the vROM tool. We developed a novel vROM scoring system, considering both seated flexion and standing extension manoeuvres, to quantify whether hips had limited ROM and then correlated the vROM score to component position. Results. The vast majority of THA planned with standing combined anteversion between 30° to 50° and sitting combined anteversion between 45° to 65° had a vROM score > 99%, while the majority of vROM scores less than 99% were outside of this zone. The range of PT in supine, standing, and sitting positions varied widely between patients. Patients who had little change in PT from standing to sitting positions had decreased hip vROM. Conclusion. It has been shown previously that an individual’s unique spinopelvic alignment influences functional cup anteversion. But functional combined anteversion, which also considers stem position, should be used to identify an ideal THA position for impingement-free ROM. We found a functional combined anteversion zone for THA that may be used moving forward to place total hip components. Cite this article: Bone Jt Open 2021;2(10):834–841


Bone & Joint Research
Vol. 6, Issue 4 | Pages 245 - 252
1 Apr 2017
Fu M Ye Q Jiang C Qian L Xu D Wang Y Sun P Ouyang J

Objectives. Many studies have investigated the kinematics of the lumbar spine and the morphological features of the lumbar discs. However, the segment-dependent immediate changes of the lumbar intervertebral space height during flexion-extension motion are still unclear. This study examined the changes of intervertebral space height during flexion-extension motion of lumbar specimens. Methods. First, we validated the accuracy and repeatability of a custom-made mechanical loading equipment set-up. Eight lumbar specimens underwent CT scanning in flexion, neural, and extension positions by using the equipment set-up. The changes in the disc height and distance between adjacent two pedicle screw entry points (DASEP) of the posterior approach at different lumbar levels (L3/4, L4/5 and L5/S1) were examined on three-dimensional lumbar models, which were reconstructed from the CT images. Results. All the vertebral motion segments (L3/4, L4/5 and L5/S1) had greater changes in disc height and DASEP from neutral to flexion than from neutral to extension. The change in anterior disc height gradually increased from upper to lower levels, from neutral to flexion. The changes in anterior and posterior disc heights were similar at the L4/5 level from neutral to extension, but the changes in anterior disc height were significantly greater than those in posterior disc height at the L3/4 and L5/S1 levels, from neutral to extension. Conclusions. The lumbar motion segment showed level-specific changes in disc height and DASEP. The data may be helpful in understanding the physiologic dynamic characteristics of the lumbar spine and in optimising the parameters of lumbar surgical instruments. Cite this article: M. Fu, Q. Ye, C. Jiang, L. Qian, D. Xu, Y. Wang, P. Sun, J. Ouyang. The segment-dependent changes in lumbar intervertebral space height during flexion-extension motion. Bone Joint Res 2017;6:245–252. DOI: 10.1302/2046-3758.64.BJR-2016-0245.R1


Bone & Joint Research
Vol. 7, Issue 1 | Pages 28 - 35
1 Jan 2018
Huang H Nightingale RW Dang ABC

Objectives. Loss of motion following spine segment fusion results in increased strain in the adjacent motion segments. However, to date, studies on the biomechanics of the cervical spine have not assessed the role of coupled motions in the lumbar spine. Accordingly, we investigated the biomechanics of the cervical spine following cervical fusion and lumbar fusion during simulated whiplash using a whole-human finite element (FE) model to simulate coupled motions of the spine. Methods. A previously validated FE model of the human body in the driver-occupant position was used to investigate cervical hyperextension injury. The cervical spine was subjected to simulated whiplash exposure in accordance with Euro NCAP (the European New Car Assessment Programme) testing using the whole human FE model. The coupled motions between the cervical spine and lumbar spine were assessed by evaluating the biomechanical effects of simulated cervical fusion and lumbar fusion. Results. Peak anterior longitudinal ligament (ALL) strain ranged from 0.106 to 0.382 in a normal spine, and from 0.116 to 0.399 in a fused cervical spine. Strain increased from cranial to caudal levels. The mean strain increase in the motion segment immediately adjacent to the site of fusion from C2-C3 through C5-C6 was 26.1% and 50.8% following single- and two-level cervical fusion, respectively (p = 0.03, unpaired two-way t-test). Peak cervical strains following various lumbar-fusion procedures were 1.0% less than those seen in a healthy spine (p = 0.61, two-way ANOVA). Conclusion. Cervical arthrodesis increases peak ALL strain in the adjacent motion segments. C3-4 experiences greater changes in strain than C6-7. Lumbar fusion did not have a significant effect on cervical spine strain. Cite this article: H. Huang, R. W. Nightingale, A. B. C. Dang. Biomechanics of coupled motion in the cervical spine during simulated whiplash in patients with pre-existing cervical or lumbar spinal fusion: A Finite Element Study. Bone Joint Res 2018;7:28–35. DOI: 10.1302/2046-3758.71.BJR-2017-0100.R1


Bone & Joint Research
Vol. 1, Issue 5 | Pages 78 - 85
1 May 2012
Entezari V Della Croce U DeAngelis JP Ramappa AJ Nazarian A Trechsel BL Dow WA Stanton SK Rosso C Müller A McKenzie B Vartanians V Cereatti A

Objectives. Cadaveric models of the shoulder evaluate discrete motion segments using the glenohumeral joint in isolation over a defined trajectory. The aim of this study was to design, manufacture and validate a robotic system to accurately create three-dimensional movement of the upper body and capture it using high-speed motion cameras. Methods. In particular, we intended to use the robotic system to simulate the normal throwing motion in an intact cadaver. The robotic system consists of a lower frame (to move the torso) and an upper frame (to move an arm) using seven actuators. The actuators accurately reproduced planned trajectories. The marker setup used for motion capture was able to determine the six degrees of freedom of all involved joints during the planned motion of the end effector. Results. The testing system demonstrated high precision and accuracy based on the expected versus observed displacements of individual axes. The maximum coefficient of variation for displacement of unloaded axes was less than 0.5% for all axes. The expected and observed actual displacements had a high level of correlation with coefficients of determination of 1.0 for all axes. Conclusions. Given that this system can accurately simulate and track simple and complex motion, there is a new opportunity to study kinematics of the shoulder under normal and pathological conditions in a cadaveric shoulder model


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 12 | Pages 1663 - 1665
1 Dec 2005
Zeifang F Carstens C Schneider S Thomsen M

Continuous passive motion has been shown to be effective in the conservative treatment of idiopathic club foot. We wished to determine whether its use after operation could improve the results in resistant club feet which required an extensive soft-tissue release. There were 50 feet in the study. Posteromedial lateral release was performed in 39 feet but two were excluded due to early relapse. The mean age at surgery was eight months (5 to 12). Each foot was assigned a Dimeglio club foot score, which was used as a primary outcome measure, before operation and at 6, 12, 18 and 44 months after. Nineteen feet were randomly selected to receive continuous passive motion and 18 had standard immobilisation in a cast. After surgery and subsequent immobilisation in a cast the Dimeglio club foot score improved from 10.3 before to 4.17 by 12 months and to 3.89 at 48 months. After operation followed by continuous passive motion the score improved from 9.68 before to 3.11 after 12 months, but deteriorated to 4.47 at 48 months. Analysis of variance adjusted for baseline values indicated a significantly better score in those having continuous passive motion up to one year after surgery, but after 18 and 48 months the outcomes were the same in both groups


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 8 | Pages 1117 - 1122
1 Aug 2005
Fuchs S Heyse T Rudofsky G Gosheger G Chylarecki C

There is a high risk of venous thromboembolism when patients are immobilised following trauma. The combination of low-molecular-weight heparin (LMWH) with graduated compression stockings is frequently used in orthopaedic surgery to try and prevent this, but a relatively high incidence of thromboembolic events remains. Mechanical devices which perform continuous passive motion imitate contractions and increase the volume and velocity of venous flow. In this study 227 trauma patients were randomised to receive either treatment with the Arthroflow device and LMWH or only with the latter. The Arthroflow device passively extends and plantarflexes the feet. Patients were assessed initially by venous-occlusion plethysmography, compression ultrasonography and continuous wave Doppler, which were repeated weekly without knowledge of the category of randomisation. Those who showed evidence of deep-vein thrombosis underwent venography for confirmation. The incidence of deep-vein thrombosis was 25% in the LMWH group compared with 3.6% in those who had additional treatment with the Arthroflow device (p < 0.001). There were no substantial complications or problems of non-compliance with the Arthroflow device. Logistic regression analysis of the risk factors of deep-vein thrombosis showed high odds ratios for operation (4.1), immobilisation (4.3), older than 40 years of age (2.8) and obesity (2.2)


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 1 | Pages 47 - 52
1 Jan 1991
Zarnett R Velazquez R Salter R

Our purpose was to determine whether continuous passive motion enhanced the quality of knee ligament reconstruction using carbon fibre. In 46 rabbits the medial collateral ligaments were excised and replaced with carbon fibre prostheses. The animals were treated postoperatively by either continuous passive motion, cast immobilisation or cage activity, termed intermittent active motion. At six weeks, the ligaments were compared histologically and biomechanically with normal (control) medial collateral ligaments and with sham-operated controls. The ligaments treated with continuous passive motion were superior to those in the other two treatment groups. There were no ligament failures in any of the groups. This study suggests that continuous passive motion, initiated immediately postoperatively, enhances the biomechanical properties of carbon fibre ligament replacement of the medial collateral ligament while preventing the harmful effects of joint immobilisation


The Journal of Bone & Joint Surgery British Volume
Vol. 54-B, Issue 3 | Pages 442 - 452
1 Aug 1972
Pennal GF Conn GS McDonald G Dale G Garside H

1. This is a preliminary report of an attempt to determine an objective reference point or "point of motion" during flexion and extension of the lumbar spine. 2. The method described uses superimposition of lateral radiographs taken in flexion and extension with the patient standing. 3. In seventy-eight radiographically normal subjects with no symptoms a "point of motion" was determined for each of the lowest three disc levels. At each level these points clustered within a specific zone approximately 2·5 centimetres square. Sixty-four per cent fell within a square centimetre. 4. In a comparative study of twenty-four patients with confirmed pathology, the "point of motion" fell outside the larger zone at the level of pathological change in 65 per cent of the disc levels. 5. The determination of the "point of motion" is a special technique for studying spinal motion. Its role as a diagnostic and prognostic aid in assessing patients with back pain is the subject of continuing study


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 5 | Pages 713 - 716
1 Sep 1994
Bischoff U Freeman M Smith D Tuke M Gregson P

We studied the wear generated by motion between polished and shot-blasted titanium-alloy (Ti-6Al-4V) or cobalt-chrome alloy (Co-Cr) surfaces and cortical bone in vitro. Semicircular sections of human proximal femoral cortex were reamed to fit metal cylinders of each alloy. The cylinders were then fitted in the bone, loaded and rotated in physiological saline. Ti-alloy resulted in more wear both of the bone and of the metal than did Co-Cr alloy. Metal wear was reduced and bone wear was increased by shot-blasting, a procedure which introduces surface residual stresses and roughens the metal surface. We conclude that when there is gross motion between a metal implant and bone, Ti-alloy is likely to generate more wear debris than Co-Cr alloy. The least wear both of bone and of metal was produced by polished Co-Cr


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 4 | Pages 591 - 595
1 Aug 1988
Chow J Thomes L Dovelle S Monsivais J Milnor W Jackson J

We present a system for treatment by controlled motion after repair of flexor tendons in the hand. This Washington regimen incorporates both controlled active extension against passive flexion by rubber band and the use of controlled passive extension and flexion. We utilise the Brooke Army Hospital modification of the rubber band passive flexion splint; this provides for maximal excursion of the tendon with full passive flexion of the finger. The 66 patients (78 fingers) who form the basis of this study all sustained complete laceration of the flexor profundus and superficialis tendons in "no man's land". Results were evaluated by the Strickland formula of total active motion (TAM) of the proximal and distal interphalangeal joints. Sixty-two fingers (80%) were rated "excellent", 14 fingers (18%) were "good", two fingers (2%) were "fair", none was rated "poor". Our regimen of controlled motion rehabilitation has also been applied with equal success to cases of flexor tendon grafting


The Bone & Joint Journal
Vol. 95-B, Issue 2 | Pages 160 - 165
1 Feb 2013
McDonnell SM Boyce G Baré J Young D Shimmin AJ

Noise generation has been reported with ceramic-on-ceramic articulations in total hip replacement (THR). This study evaluated 208 consecutive Delta Motion THRs at a mean follow-up of 21 months (12 to 35). There were 141 women and 67 men with a mean age of 59 years (22 to 84). Patients were reviewed clinically and radiologically, and the incidence of noise was determined using a newly described assessment method. Noise production was examined against range of movement, ligamentous laxity, patient-reported outcome scores, activity level and orientation of the acetabular component. There were 143 silent hips (69%), 22 (11%) with noises other than squeaking, 17 (8%) with unreproducible squeaking and 26 (13%) with reproducible squeaking. Hips with reproducible squeaking had a greater mean range of movement (p < 0.001) and mean ligament laxity (p = 0.004), smaller median head size (p = 0.01) and decreased mean acetabular component inclination (p = 0.02) and anteversion angle (p = 0.02) compared with the other groups. There was no relationship between squeaking and age (p = 0.13), height (p = 0.263), weight (p = 0.333), body mass index (p = 0.643), gender (p = 0.07) or patient outcome score (p = 0.422). There were no revisions during follow-up. Despite the surprisingly high incidence of squeaking, all patients remain satisfied with their hip replacement. Cite this article: Bone Joint J 2013;95-B:160–5


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 1 | Pages 140 - 146
1 Jan 1997
Robinson RP Simonian PT Gradisar IM Ching RP

A three-dimensional computer model of a total hip replacement was used to examine the relationship between the position of the components, the range of motion and the prosthetic joint contact area. Horizontal acetabular positions with small amounts of acetabular and femoral anteversion provide the largest contact areas, but result in limited joint movement. These data will allow surgeons to select implant positions that will provide the largest possible joint contact area for a given joint range of motion although these are conflicting goals. In some component positions a truncated spherical prosthetic head resulted in smaller contact areas than a completely spherical head


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 5 | Pages 659 - 667
1 Sep 1992
Moran M Kim H Salter R

We compared the effects of continuous passive motion with those of intermittent active motion on the results of the resurfacing with autogenous periosteal grafts of full-thickness defects on the articular surface of rabbit patellae. Of 45 rabbits with defects, 30 received grafts. Fifteen of these had continuous passive motion for two weeks and intermittent active motion for four weeks; the other 15 had intermittent active motion for six weeks. In 15 the defects were not grafted (control group) and they had intermittent active motion for six weeks. Ten more rabbits had a sham operation. Six weeks after surgery, the results were assessed by the gross appearance, histology, histochemistry, immunohistochemistry and electron microscopy. By all assessments the quality of neochondrogenesis produced by periosteal grafts was superior to that in ungrafted defects (p less than 0.05) and the results in continuous passive motion treated animals were superior to those in intermittent active motion treated animals (p less than 0.05). The periosteal grafts produced hyaline cartilage containing type II collagen but the organisation of its fibres was irregular


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 6 | Pages 914 - 917
1 Nov 1997
Pope RO Corcoran S McCaul K Howie DW

We report a prospective randomly controlled trial to examine the effectiveness of continuous passive motion (CPM) in improving postoperative function and range of movement after total knee arthroplasty (TKA). We allocated 53 patients (57 knees) to one of three postoperative regimes: no CPM (n = 19); CPM at 0 to 40° (0 to 40 CPM; n = 18); and CPM at 0 to 70° (0 to 70 CPM; n = 20). Those in the CPM groups had CPM for 48 hours and all patients had an identical regime of physiotherapy. There was an even distribution of various cemented and cementless TKAs in each group. Patients were assessed preoperatively and at one week and at one year postoperatively. At one week, there was a statistically significant increase in the range of flexion and total range of movement in the 0 to 70 CPM group compared with the no-CPM group. At one year we found no significant differences in mean flexion, overall range of movement, fixed flexion deformity or functional results in the three groups. Those who had CPM had a significant increase in analgesic requirement (p = 0.04). There was an increased mean blood drainage postoperatively in those who had 0 to 70 CPM (1558 ml) compared with those with no CPM (956 ml) (t = 2.96, p = 0.005) and with 0 to 40 CPM (1017 ml) (t = 2.62, p = 0.01). Our findings show that CPM had no significant advantage in terms of improving function or range of movement, and that its use increased blood loss and analgesic requirements


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 5 | Pages 802 - 806
1 Nov 1988
Laupattarakasem W

Continuous passive motion (CPM) is an established method of preventing joint stiffness and of overcoming it. The optimum duration of treatment, however, is not known, though a period of one to three weeks is usual. This may be unnecessarily long and a programme lasting only three days has been tried in 34 patients: in 22 (Group A) treatment was designed to increase movement in stiff joints which had been operated on or manipulated, and in 12 (Group B) it was to prevent stiffness after an injury. A specially designed CPM device was used. In Group A, the range by the third day of treatment was significantly greater than before manipulation or operation and this increase was maintained until the latest follow-up at an average of 24 weeks. In Group B, the pre-injury range was almost retained and thereafter there was a gradual increase. Patient compliance in the first 12 hours of CPM was relatively poorer than that described in previous reports, and in five patients treatment had to be discontinued