Results 1 - 77 of 77
Results per page:
The Bone & Joint Journal
Vol. 104-B, Issue 12 | Pages 1334 - 1342
1 Dec 2022
Wilcox B Campbell RJ Low A Yeoh T

Aims. Rates of reverse total shoulder arthroplasty (rTSA) continue to grow. Glenoid bone loss and deformity remains a technical challenge to the surgeon and may reduce improvements in patients’ outcomes. However, there is no consensus as to the optimal surgical technique to best reconstruct these patients’ anatomy. This review aims to compare the outcomes of glenoid bone grafting versus augmented glenoid prostheses in the management of glenoid bone loss in primary reverse total shoulder arthroplasty. Methods. This systematic review and meta-analysis evaluated study-level data in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement. We performed searches of Medline (Ovid), Embase (Ovid), and PubMed from their dates of inception to January 2022. From included studies, we analyzed data for preoperative and postoperative range of motion (ROM), patient-reported functional outcomes, and complication rates. Results. A total of 13 studies (919 shoulders) were included in the analysis. The mean age of patients at initial evaluation was 72.2 years (42 to 87), with a mean follow-up time of 40.7 months (24 to 120). Nine studies with 292 rTSAs evaluated the use of bone graft and five studies with 627 rTSAs evaluated the use of augmented glenoid baseplates. One study was analyzed in both groups. Both techniques demonstrated improvement in patient-reported outcome measures and ROM assessment, with augmented prostheses outperforming bone grafting on improvements in the American Shoulder and Elbow Surgeons Score. There was a higher complication rate (8.9% vs 3.5%; p < 0.001) and revision rate among the bone grafting group compared with the patients who were treated with augmented prostheses (2.4% vs 0.6%; p = 0.022). Conclusion. This review provides strong evidence that both bone graft and augmented glenoid baseplate techniques to address glenoid bone loss give excellent ROM and functional outcomes in primary rTSA. The use of augmented base plates may confer fewer complications and revisions. Cite this article: Bone Joint J 2022;104-B(12):1334–1342


The Bone & Joint Journal
Vol. 103-B, Issue 10 | Pages 1619 - 1626
1 Oct 2021
Bi M Zhou K Gan K Ding W Zhang T Ding S Li J

Aims. The aim of this study is to provide a detailed description of cases combining bridging patch repair with artificial ligament “internal brace” reinforcement to treat irreparable massive rotator cuff tears, and report the preliminary results. Methods. This is a retrospective review of patients with irreparable massive rotator cuff tears undergoing fascia lata autograft bridging repair with artificial ligament “internal brace” reinforcement technique between January 2017 and May 2018. Inclusion criteria were: patients treated arthroscopically for an incompletely reparable massive rotator cuff tear (dimension > 5 cm or two tendons fully torn), stage 0 to 4 supraspinatus fatty degeneration on MRI according to the Goutallier grading system, and an intact or reparable infraspinatus and/or subscapularis tendon of radiological classification Hamada 0 to 4. The surgical technique comprised two components: first, superior capsular reconstruction using an artificial ligament as an “internal brace” protective device for a fascia lata patch. The second was fascia lata autograft bridging repair for the torn supraspinatus. In all, 26 patients with a mean age 63.4 years (SD 6.2) were included. Results. All patients underwent more than two years of follow-up (mean 33.5 months (24 to 45)). All clinical scores were also improved at two-year follow-up (mean visual analogue scale 0.7 (SD 0.5) vs 6.1 (SD 1.2); p < 0.001; mean American Shoulder and Elbow Surgeons score 93.5 (SD 5.3) vs 42.5 (SD 10.8); p < 0.001; mean University of California, Los Angeles score, 31.7 (SD 3.7) vs 12.0 (SD 3.1); p < 0.001; and mean Constant-Murley score 88.7 (SD 3.5) vs 43.3 (SD 10.9); p < 0.001), and 24 of 26 fascia lata grafts were fully healed on MRI (92%). One patient had haematoma formation at the harvesting side of the fascia lata at two days postoperatively. Conclusion. The fascia lata autograft bridging repair combined with artificial ligament internal brace reinforcement technique achieved good functional outcomes, with a high rate of graft healing at two-year follow-up. Although the short-term results are promising, further studies with a greater number of patients would provide clearer results. Cite this article: Bone Joint J 2021;103-B(10):1619–1626


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1141 - 1149
1 Oct 2024
Saleem J Rawi B Arnander M Pearse E Tennent D

Aims

Extensive literature exists relating to the management of shoulder instability, with a more recent focus on glenoid and humeral bone loss. However, the optimal timing for surgery following a dislocation remains unclear. There is concern that recurrent dislocations may worsen subsequent surgical outcomes, with some advocating stabilization after the first dislocation. The aim of this study was to determine if the recurrence of instability following arthroscopic stabilization in patients without significant glenoid bone loss was influenced by the number of dislocations prior to surgery.

Methods

A systematic review and meta-analysis was performed using the PubMed, EMBASE, Orthosearch, and Cochrane databases with the following search terms: ((shoulder or glenohumeral) and (dislocation or subluxation) and arthroscopic and (Bankart or stabilisation or stabilization) and (redislocation or re-dislocation or recurrence or instability)). Methodology followed the PRISMA guidelines. Data and outcomes were synthesized by two independent reviewers, and papers were assessed for bias and quality.


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1327 - 1332
1 Nov 2024
Ameztoy Gallego J Diez Sanchez B Vaquero-Picado A Antuña S Barco R

Aims

In patients with a failed radial head arthroplasty (RHA), simple removal of the implant is an option. However, there is little information in the literature about the outcome of this procedure. The aim of this study was to review the mid-term clinical and radiological results, and the rate of complications and removal of the implant, in patients whose initial RHA was undertaken acutely for trauma involving the elbow.

Methods

A total of 11 patients in whom removal of a RHA without reimplantation was undertaken as a revision procedure were reviewed at a mean follow-up of 8.4 years (6 to 11). The range of motion (ROM) and stability of the elbow were recorded. Pain was assessed using a visual analogue scale (VAS). The functional outcome was assessed using the Mayo Elbow Performance Score (MEPS), the Oxford Elbow Score (OES), and the Disabilities of the Arm, Shoulder and Hand questionnaire (DASH). Radiological examination included the assessment of heterotopic ossification (HO), implant loosening, capitellar erosion, overlengthening, and osteoarthritis. Complications and the rate of further surgery were also recorded.


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1118 - 1124
1 Oct 2024
Long Y Zheng Z Li X Cui D Deng X Guo J Yang R

Aims

The aims of this study were to validate the minimal clinically important difference (MCID) and patient-acceptable symptom state (PASS) thresholds for Western Ontario Shoulder Instability Index (WOSI), Rowe score, American Shoulder and Elbow Surgeons (ASES), and visual analogue scale (VAS) scores following arthroscopic Bankart repair, and to identify preoperative threshold values of these scores that could predict the achievement of MCID and PASS.

Methods

A retrospective review was conducted on 131 consecutive patients with anterior shoulder instability who underwent arthroscopic Bankart repair between January 2020 and January 2023. Inclusion criteria required at least one episode of shoulder instability and a minimum follow-up period of 12 months. Preoperative and one-year postoperative scores were assessed. MCID and PASS were estimated using distribution-based and anchor-based methods, respectively. Receiver operating characteristic curve analysis determined preoperative patient-reported outcome measure thresholds predictive of achieving MCID and PASS.


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1100 - 1110
1 Oct 2024
Arenas-Miquelez A Barco R Cabo Cabo FJ Hachem A

Bone defects are frequently observed in anterior shoulder instability. Over the last decade, knowledge of the association of bone loss with increased failure rates of soft-tissue repair has shifted the surgical management of chronic shoulder instability. On the glenoid side, there is no controversy about the critical glenoid bone loss being 20%. However, poor outcomes have been described even with a subcritical glenoid bone defect as low as 13.5%. On the humeral side, the Hill-Sachs lesion should be evaluated concomitantly with the glenoid defect as the two sides of the same bipolar lesion which interact in the instability process, as described by the glenoid track concept. We advocate adding remplissage to every Bankart repair in patients with a Hill-Sachs lesion, regardless of the glenoid bone loss. When critical or subcritical glenoid bone loss occurs in active patients (> 15%) or bipolar off-track lesions, we should consider anterior glenoid bone reconstructions. The techniques have evolved significantly over the last two decades, moving from open procedures to arthroscopic, and from screw fixation to metal-free fixation. The new arthroscopic techniques of glenoid bone reconstruction procedures allow precise positioning of the graft, identification, and treatment of concomitant injuries with low morbidity and faster recovery. Given the problems associated with bone resorption and metal hardware protrusion, the new metal-free techniques for Latarjet or free bone block procedures seem a good solution to avoid these complications, although no long-term data are yet available.

Cite this article: Bone Joint J 2024;106-B(10):1100–1110.


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 970 - 977
1 Sep 2024
De Rus Aznar I Ávila Lafuente JL Hachem A Díaz Heredia J Kany J Elhassan B Ruiz Ibán MÁ

Rotator cuff pathology is the main cause of shoulder pain and dysfunction in older adults. When a rotator cuff tear involves the subscapularis tendon, the symptoms are usually more severe and the prognosis after surgery must be guarded. Isolated subscapularis tears represent 18% of all rotator cuff tears and arthroscopic repair is a good alternative primary treatment. However, when the tendon is deemed irreparable, tendon transfers are the only option for younger or high-functioning patients. The aim of this review is to describe the indications, biomechanical principles, and outcomes which have been reported for tendon transfers, which are available for the treatment of irreparable subscapularis tears.

The best tendon to be transferred remains controversial. Pectoralis major transfer was described more than 30 years ago to treat patients with failed surgery for instability of the shoulder. It has subsequently been used extensively to manage irreparable subscapularis tendon tears in many clinical settings. Although pectoralis major reproduces the position and orientation of the subscapularis in the coronal plane, its position in the axial plane – anterior to the rib cage – is clearly different and does not allow it to function as an ideal transfer. Consistent relief of pain and moderate recovery of strength and function have been reported following the use of this transfer. In an attempt to improve on these results, latissimus dorsi tendon transfer was proposed as an alternative and the technique has evolved from an open to an arthroscopic procedure. Satisfactory relief of pain and improvements in functional shoulder scores have recently been reported following its use. Both pectoralis minor and upper trapezius transfers have also been used in these patients, but the outcomes that have been reported do not support their widespread use.

Cite this article: Bone Joint J 2024;106-B(9):970–977.


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1301 - 1305
1 Nov 2024
Prajapati A Thakur RPS Gulia A Puri A

Aims

Reconstruction after osteoarticular resection of the proximal ulna for tumours is technically difficult and little has been written about the options that are available. We report a series of four patients who underwent radial neck to humeral trochlea transposition arthroplasty following proximal ulnar osteoarticular resection.

Methods

Between July 2020 and July 2022, four patients with primary bone tumours of the ulna underwent radial neck to humeral trochlea transposition arthroplasty. Their mean age was 28 years (12 to 41). The functional outcome was assessed using the range of motion (ROM) of the elbow, rotation of the forearm and stability of the elbow, the Musculoskeletal Tumor Society score (MSTS), and the nine-item abbreviated version of the Disabilities of the Arm, Shoulder and Hand questionnaire (QuickDASH-9) score.


Bone & Joint Open
Vol. 5, Issue 10 | Pages 929 - 936
22 Oct 2024
Gutierrez-Naranjo JM Salazar LM Kanawade VA Abdel Fatah EE Mahfouz M Brady NW Dutta AK

Aims

This study aims to describe a new method that may be used as a supplement to evaluate humeral rotational alignment during intramedullary nail (IMN) insertion using the profile of the perpendicular peak of the greater tuberosity and its relation to the transepicondylar axis. We called this angle the greater tuberosity version angle (GTVA).

Methods

This study analyzed 506 cadaveric humeri of adult patients. All humeri were CT scanned using 0.625 × 0.625 × 0.625 mm cubic voxels. The images acquired were used to generate 3D surface models of the humerus. Next, 3D landmarks were automatically calculated on each 3D bone using custom-written C++ software. The anatomical landmarks analyzed were the transepicondylar axis, the humerus anatomical axis, and the peak of the perpendicular axis of the greater tuberosity. Lastly, the angle between the transepicondylar axis and the greater tuberosity axis was calculated and defined as the GTVA.


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 182 - 188
1 Feb 2024
Gallego JA Rotman D Watts AC

Aims

Acute and chronic injuries of the interosseus membrane can result in longitudinal instability of the forearm. Reconstruction of the central band of the interosseus membrane can help to restore biomechanical stability. Different methods have been used to reconstruct the central band, including tendon grafts, bone-ligament-bone grafts, and synthetic grafts. This Idea, Development, Exploration, Assessment, and Long-term (IDEAL) phase 1 study aims to review the clinical results of reconstruction using a synthetic braided cross-linked graft secured at either end with an Endobutton to restore the force balance between the bones of the forearm.

Methods

An independent retrospective review was conducted of a consecutive series of 21 patients with longitudinal instability injuries treated with anatomical central band reconstruction between February 2011 and July 2019. Patients with less than 12 months’ follow-up or who were treated acutely were excluded, leaving 18 patients in total. Preoperative clinical and radiological assessments were compared with prospectively gathered data using range of motion and the abbreviated version of the Disabilities of the Arm, Shoulder and Hand questionnaire (QuickDASH) functional outcome score.


Bone & Joint Open
Vol. 5, Issue 10 | Pages 818 - 824
2 Oct 2024
Moroder P Herbst E Pawelke J Lappen S Schulz E

Aims

The liner design is a key determinant of the constraint of a reverse total shoulder arthroplasty (rTSA). The aim of this study was to compare the degree of constraint of rTSA liners between different implant systems.

Methods

An implant company’s independent 3D shoulder arthroplasty planning software (mediCAD 3D shoulder v. 7.0, module v. 2.1.84.173.43) was used to determine the jump height of standard and constrained liners of different sizes (radius of curvature) of all available companies. The obtained parameters were used to calculate the stability ratio (degree of constraint) and angle of coverage (degree of glenosphere coverage by liner) of the different systems. Measurements were independently performed by two raters, and intraclass correlation coefficients were calculated to perform a reliability analysis. Additionally, measurements were compared with parameters provided by the companies themselves, when available, to ensure validity of the software-derived measurements.


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1158 - 1164
1 Oct 2024
Jakobi T Krieg I Gramlich Y Sauter M Schnetz M Hoffmann R Klug A

Aims

The aim of this study was to evaluate the outcome of complex radial head fractures at mid-term follow-up, and determine whether open reduction and internal fixation (ORIF) or radial head arthroplasty (RHA) should be recommended for surgical treatment.

Methods

Patients who underwent surgery for complex radial head fractures (Mason type III, ≥ three fragments) were divided into two groups (ORIF and RHA) and propensity score matching was used to individually match patients based on patient characteristics. Ultimately, 84 patients were included in this study. After a mean follow-up of 4.1 years (2.0 to 9.5), patients were invited for clinical and radiological assessment. The Mayo Elbow Performance Score (MEPS), Oxford Elbow Score (OES), and Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire score were evaluated.


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1111 - 1117
1 Oct 2024
Makaram NS Becher H Oag E Heinz NR McCann CJ Mackenzie SP Robinson CM

Aims

The risk factors for recurrent instability (RI) following a primary traumatic anterior shoulder dislocation (PTASD) remain unclear. In this study, we aimed to determine the rate of RI in a large cohort of patients managed nonoperatively after PTASD and to develop a clinical prediction model.

Methods

A total of 1,293 patients with PTASD managed nonoperatively were identified from a trauma database (mean age 23.3 years (15 to 35); 14.3% female). We assessed the prevalence of RI, and used multivariate regression modelling to evaluate which demographic- and injury-related factors were independently predictive for its occurrence.


The Bone & Joint Journal
Vol. 105-B, Issue 11 | Pages 1189 - 1195
1 Nov 2023
Kim JS Kim SH Kim SC Park JH Kim HG Lee SM Yoo JC

Aims

The aim of this study was to compare the clinical and radiological outcomes of reverse shoulder arthroplasty (RSA) using small and standard baseplates in Asian patients, and to investigate the impact of a mismatch in the sizes of the glenoid and the baseplate on the outcomes.

Methods

This was retrospective analysis of 50 and 33 RSAs using a standard (33.8 mm, ST group) and a small (29.5 mm, SM group) baseplate of the Equinoxe reverse shoulder system, which were undertaken between January 2017 and March 2021. Radiological evaluations included the size of the glenoid, the β-angle, the inclination of the glenoid component, inferior overhang, scapular notching, the location of the central cage in the baseplate within the vault and the mismatch in size between the glenoid and baseplate. Clinical evaluations included the range of motion (ROM) and functional scores. In subgroup analysis, comparisons were performed between those in whom the vault of the glenoid was perforated (VP group) and those in whom it was not perforated (VNP group).


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 978 - 985
1 Sep 2024
Savoie III FH Delvadia BP Tate JP Winter JE Williams GH Sherman WF O’Brien MJ

Rotator cuff tears are common in middle-aged and elderly patients. Despite advances in the surgical repair of rotator cuff tears, the rates of recurrent tear remain high. This may be due to the complexity of the tendons of the rotator cuff, which contributes to an inherently hostile healing environment. During the past 20 years, there has been an increased interest in the use of biologics to complement the healing environment in the shoulder, in order to improve rotator cuff healing and reduce the rate of recurrent tears. The aim of this review is to provide a summary of the current evidence for the use of forms of biological augmentation when repairing rotator cuff tears.

Cite this article: Bone Joint J 2024;106-B(9):978–985.


Bone & Joint Open
Vol. 4, Issue 1 | Pages 19 - 26
13 Jan 2023
Nishida K Nasu Y Hashizume K Okita S Nakahara R Saito T Ozaki T Inoue H

Aims

There are concerns regarding complications and longevity of total elbow arthroplasty (TEA) in young patients, and the few previous publications are mainly limited to reports on linked elbow devices. We investigated the clinical outcome of unlinked TEA for patients aged less than 50 years with rheumatoid arthritis (RA).

Methods

We retrospectively reviewed the records of 26 elbows of 21 patients with RA who were aged less than 50 years who underwent primary TEA with an unlinked elbow prosthesis. The mean patient age was 46 years (35 to 49), and the mean follow-up period was 13.6 years (6 to 27). Outcome measures included pain, range of motion, Mayo Elbow Performance Score (MEPS), radiological evaluation for radiolucent line and loosening, complications, and revision surgery with or without implant removal.


Bone & Joint Open
Vol. 3, Issue 10 | Pages 826 - 831
28 Oct 2022
Jukes C Dirckx M Bellringer S Chaundy W Phadnis J

Aims

The conventionally described mechanism of distal biceps tendon rupture (DBTR) is of a ‘considerable extension force suddenly applied to a resisting, actively flexed forearm’. This has been commonly paraphrased as an ‘eccentric contracture to a flexed elbow’. Both definitions have been frequently used in the literature with little objective analysis or citation. The aim of the present study was to use video footage of real time distal biceps ruptures to revisit and objectively define the mechanism of injury.

Methods

An online search identified 61 videos reporting a DBTR. Videos were independently reviewed by three surgeons to assess forearm rotation, elbow flexion, shoulder position, and type of muscle contraction being exerted at the time of rupture. Prospective data on mechanism of injury and arm position was also collected concurrently for 22 consecutive patients diagnosed with an acute DBTR in order to corroborate the video analysis.


The Bone & Joint Journal
Vol. 98-B, Issue 9 | Pages 1208 - 1214
1 Sep 2016
Cowling PD Akhtar MA Liow RYL

Objectives. A variety of operative techniques have been described as under the term ‘Bristow-Latarjet’ procedure. This review aims to define the original procedure, and compare the variation in techniques described in the literature, assessing any effect on clinical outcomes. Materials and Methods. A systematic review of 24 studies was performed to compare specific steps of the technique (coracoid osteotomy site, subscapularis approach, orientation and position of coracoid graft fixation and fixation method, additional labral and capsular repair) and detect any effect this variability had on outcomes. Results. Overall recurrence rate was 5.36% (2.94% to 43%). Half of the studies performed the procedure for recurrent shoulder instability, with only five studies documenting glenoid bone loss as an indication: 12 studies used the procedure as the primary surgical intervention for recurrent instability. No change in outcome was noted when examining variation in the coracoid osteotomy site, the fixation site on the scapular neck, the fixation method or whether a capsular repair was also performed. Performing a horizontal split in subscapularis may preserve external rotation compared with performing a tenotomy. Conclusions. This is the first review to examine various operative techniques of the Bristow-Latarjet procedure, and their effect on outcome. We found that other than the approach through subscapularis, outcome was independent of the surgical technique, and depended more on patient selection. We would commend future publications on this procedure to provide a detailed description of the surgical technique, and as a minimum present rates of recurrence as an outcome measure. Cite this article: Bone Joint J 2016;98-B:1208–14


The Bone & Joint Journal
Vol. 105-B, Issue 4 | Pages 389 - 399
15 Mar 2023
Makaram NS Nicholson JA Yapp LZ Gillespie M Shah CP Robinson CM

Aims

The open Latarjet procedure is a widely used treatment for recurrent anterior instability of the shoulder. Although satisfactory outcomes are reported, factors which influence a patient’s experience are poorly quantified. The aim of this study was to evaluate the effect of a range of demographic factors and measures of the severity of instability on patient-reported outcome measures in patients who underwent an open Latarjet procedure at a minimum follow-up of two years.

Methods

A total of 350 patients with anterior instability of the shoulder who underwent an open Latarjet procedure between 2005 and 2018 were reviewed prospectively, with the collection of demographic and psychosocial data, preoperative CT, and complications during follow-up of two years. The primary outcome measure was the Western Ontario Shoulder Instability Index (WOSI), assessed preoperatively, at two years postoperatively, and at mid-term follow-up at a mean of 50.6 months (SD 24.8) postoperatively. The secondary outcome measure was the abbreviated version of the Disabilities of the Arm, Shoulder and Hand (QuickDASH) score. The influence of the demographic details of the patients, measurements of the severity of instability, and the complications of surgery were assessed in a multivariate analysis.


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1303 - 1313
1 Dec 2023
Trammell AP Hao KA Hones KM Wright JO Wright TW Vasilopoulos T Schoch BS King JJ

Aims

Both anatomical and reverse total shoulder arthroplasty (aTSA and rTSA) provide functional improvements. A reported benefit of aTSA is better range of motion (ROM). However, it is not clear which procedure provides better outcomes in patients with limited foward elevation (FE). The aim of this study was to compare the outcome of aTSA and rTSA in patients with glenohumeral osteoarthritis (OA), an intact rotator cuff, and limited FE.

Methods

This was a retrospective review of a single institution’s prospectively collected shoulder arthroplasty database for TSAs undertaken between 2007 and 2020. A total of 344 aTSAs and 163 rTSAs, which were performed in patients with OA and an intact rotator cuff with a minimum follow-up of two years, were included. Using the definition of preoperative stiffness as passive FE ≤ 105°, three cohorts were matched 1:1 by age, sex, and follow-up: stiff aTSAs (85) to non-stiff aTSAs (85); stiff rTSAs (74) to non-stiff rTSAs (74); and stiff rTSAs (64) to stiff aTSAs (64). We the compared ROMs, outcome scores, and complication and revision rates.


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 668 - 678
1 Jun 2023
Friedman RJ Boettcher ML Grey S Flurin P Wright TW Zuckerman JD Eichinger JK Roche C

Aims

The aim of this study was to longitudinally compare the clinical and radiological outcomes of anatomical total shoulder arthroplasty (aTSA) up to long-term follow-up, when using cemented keel, cemented peg, and hybrid cage peg glenoid components and the same humeral system.

Methods

We retrospectively analyzed a multicentre, international clinical database of a single platform shoulder system to compare the short-, mid-, and long-term clinical outcomes associated with three designs of aTSA glenoid components: 294 cemented keel, 527 cemented peg, and 981 hybrid cage glenoids. Outcomes were evaluated at 4,746 postoperative timepoints for 1,802 primary aTSA, with a mean follow-up of 65 months (24 to 217).


Bone & Joint Open
Vol. 3, Issue 10 | Pages 815 - 825
20 Oct 2022
Athanatos L Kulkarni K Tunnicliffe H Samaras M Singh HP Armstrong AL

Aims

There remains a lack of consensus regarding the management of chronic anterior sternoclavicular joint (SCJ) instability. This study aimed to assess whether a standardized treatment algorithm (incorporating physiotherapy and surgery and based on the presence of trauma) could successfully guide management and reduce the number needing surgery.

Methods

Patients with chronic anterior SCJ instability managed between April 2007 and April 2019 with a standardized treatment algorithm were divided into non-traumatic (offered physiotherapy) and traumatic (offered surgery) groups and evaluated at discharge. Subsequently, midterm outcomes were assessed via a postal questionnaire with a subjective SCJ stability score, Oxford Shoulder Instability Score (OSIS, adapted for the SCJ), and pain visual analogue scale (VAS), with analysis on an intention-to-treat basis.


The Bone & Joint Journal
Vol. 104-B, Issue 4 | Pages 486 - 494
4 Apr 2022
Liu W Sun Z Xiong H Liu J Lu J Cai B Wang W Fan C

Aims

The aim of this study was to develop and internally validate a prognostic nomogram to predict the probability of gaining a functional range of motion (ROM ≥ 120°) after open arthrolysis of the elbow in patients with post-traumatic stiffness of the elbow.

Methods

We developed the Shanghai Prediction Model for Elbow Stiffness Surgical Outcome (SPESSO) based on a dataset of 551 patients who underwent open arthrolysis of the elbow in four institutions. Demographic and clinical characteristics were collected from medical records. The least absolute shrinkage and selection operator regression model was used to optimize the selection of relevant features. Multivariable logistic regression analysis was used to build the SPESSO. Its prediction performance was evaluated using the concordance index (C-index) and a calibration graph. Internal validation was conducted using bootstrapping validation.


The Bone & Joint Journal
Vol. 104-B, Issue 3 | Pages 394 - 400
1 Mar 2022
Lee KJ Kim YT Choi M Kim SH

Aims

The aim of this study was to compare the characteristics and outcomes of L-shaped and reverse L-shaped rotator cuff tears.

Methods

A total of 82 shoulders (81 patients) after arthroscopic rotator cuff repair were retrospectively enrolled. The mean age of the patients was 62 years (SD 6), 33 shoulders (40.2%) were in male patients, and 57 shoulders (69.5%) were the right shoulder. Of these, 36 shoulders had an L-shaped tear (group L) and 46 had a reverse L-shaped tear (group RL). Both groups were compared regarding characteristics, pre- and postoperative pain, and functional outcomes. Muscle status was assessed by preoperative MRI, and re-tear rates by postoperative ultrasonography or MRI.


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 91 - 96
1 Jan 2022
Modi A Haque A Deore V Singh HP Pandey R

Aims

Long-term outcomes following the use of human dermal allografts in the treatment of symptomatic irreparable rotator cuff tears are not known. The aim of this study was to evaluate these outcomes, and to investigate whether this would be a good form of treatment in young patients in whom a reverse shoulder arthroplasty should ideally be avoided.

Methods

This prospective study included 47 shoulders in 45 patients who underwent an open reconstruction of the rotator cuff using an interposition GraftJacket allograft to bridge irreparable cuff tears, between January 2007 and November 2011. The Oxford Shoulder Score (OSS), pain score, and range of motion (ROM) were recorded preoperatively and at one year and a mean of 9.1 years (7.0 to 12.5) postoperatively.


The Bone & Joint Journal
Vol. 98-B, Issue 4 | Pages 512 - 518
1 Apr 2016
Spencer HT Hsu L Sodl J Arianjam A Yian EH

Aims. To compare radiographic failure and re-operation rates of anatomical coracoclavicular (CC) ligament reconstructional techniques with non-anatomical techniques after chronic high grade acromioclavicular (AC) joint injuries. . Patients and Methods. We reviewed chronic AC joint reconstructions within a region-wide healthcare system to identify surgical technique, complications, radiographic failure and re-operations. Procedures fell into four categories: (1) modified Weaver-Dunn, (2) allograft fixed through coracoid and clavicular tunnels, (3) allograft loop coracoclavicular fixation, and (4) combined allograft loop and synthetic cortical button fixation. Among 167 patients (mean age 38.1 years, (standard deviation (. sd. ) 14.7) treated at least a four week interval after injury, 154 had post-operative radiographs available for analysis. . Results. Radiographic failure occurred in 33/154 cases (21.4%), with the lowest rate in Technique 4 (2/42 4.8%, p = 0.001). Half the failures occurred by six weeks, and the Kaplan-Meier survivorship at 24 months was 94.4% (95% confidence interval (CI) 79.6 to 98.6) for Technique 4 and 69.9% (95% CI 59.4 to 78.3) for the other techniques when combined. In multivariable survival analysis, Technique 4 had better survival than other techniques (Hazard Ratio 0.162, 95% CI 0.039 to 0.068, p = 0.013). Among 155 patients with a minimum of six months post-operative insurance coverage, re-operation occurred in 9.7% (15 patients). However, in multivariable logistic regression, Technique 4 did not reach a statistically significant lower risk for re-operation (odds ratio 0.254, 95% CI 0.05 to 1.3, p = 0.11). Conclusion. In this retrospective series, anatomical CC ligament reconstruction using combined synthetic cortical button and allograft loop fixation had the lowest rate of radiographic failure. . Take home message: Anatomical coracoclavicular ligament reconstruction using combined synthetic cortical button and allograft loop fixation had the lowest rate of radiographic failure. Cite this article: Bone Joint J 2016;98-B:512–18


The Bone & Joint Journal
Vol. 103-B, Issue 8 | Pages 1333 - 1338
2 Aug 2021
Kankanalu P Borton ZM Morgan ML Cresswell T Espag MP Tambe AA Clark DI

Aims

Reverse total shoulder arthroplasty (RTSA) using trabecular metal (TM)-backed glenoid implants has been introduced with the aim to increase implant survival. Only short-term reports on the outcomes of TM-RTSA have been published to date. We aim to present the seven-year survival of TM-backed glenoid implants along with minimum five-year clinical and radiological outcomes.

Methods

All consecutive elective RTSAs performed at a single centre between November 2008 and October 2014 were reviewed. Patients who had primary TM-RTSA for rotator cuff arthropathy and osteoarthritis with deficient cuff were included. A total of 190 shoulders in 168 patients (41 male, 127 female) were identified for inclusion at a mean of 7.27 years (SD 1.4) from surgery. The primary outcome was survival of the implant with all-cause revision and aseptic glenoid loosening as endpoints. Secondary outcomes were clinical, radiological, and patient-related outcomes with a five-year minimum follow-up.


The Bone & Joint Journal
Vol. 103-B, Issue 7 | Pages 1292 - 1300
1 Jul 2021
Märtens N Heinze M Awiszus F Bertrand J Lohmann CH Berth A

Aims

The purpose of this study was to compare clinical results, long-term survival, and complication rates of stemless shoulder prosthesis with stemmed anatomical shoulder prostheses for treatment of osteoarthritis and to analyze radiological bone changes around the implants during follow-up.

Methods

A total of 161 patients treated with either a stemmed or a stemless shoulder arthroplasty for primary osteoarthritis of the shoulder were evaluated with a mean follow-up of 118 months (102 to 158). The Constant score (CS), the Disabilities of the Arm, Shoulder and Hand (DASH) score, and active range of motion (ROM) were recorded. Radiological analysis for bone adaptations was performed by plain radiographs. A Kaplan-Meier survivorship analysis was calculated and complications were noted.


The Bone & Joint Journal
Vol. 103-B, Issue 1 | Pages 123 - 130
1 Jan 2021
Lapner P Pollock JW Laneuville O Uhthoff HK Zhang T Sheikh A McIlquham K Trudel G

Aims

Despite recent advances in arthroscopic rotator cuff repair, re-tear rates remain high. New methods to improve healing rates following rotator cuff repair must be sought. Our primary objective was to determine if adjunctive bone marrow stimulation with channelling five to seven days prior to arthroscopic cuff repair would lead to higher Western Ontario Rotator Cuff (WORC) scores at 24 months postoperatively compared with no channelling.

Methods

A prospective, randomized controlled trial was conducted in patients undergoing arthroscopic rotator cuff repair. Patients were randomized to receive either a percutaneous bone channelling of the rotator cuff footprint or a sham procedure under ultrasound guidance five to seven days prior to index surgery. Outcome measures included the WORC, American Shoulder and Elbow Surgeons (ASES), and Constant scores, strength, ultrasound-determined healing rates, and adverse events.


The Bone & Joint Journal
Vol. 103-B, Issue 3 | Pages 530 - 535
1 Mar 2021
Giannicola G Castagna V Villani C Gumina S Scacchi M

Aims

It has been hypothesized that proximal radial neck resorption (PRNR) following press-fit radial head arthroplasty (RHA) is due to stress-shielding. We compared two different press-fit stems by means of radiographs to investigate whether the shape and size of the stems are correlated with the degree of PRNR.

Methods

The radiographs of 52 RHAs were analyzed both at 14 days postoperatively and after two years. A cylindrical stem and a conical stem were implanted in 22 patients (group 1) and 30 patients (group 2), respectively. The PRNR was measured in the four quadrants of the radial neck and the degree of stem filling was calculated by analyzing the ratio between the prosthetic stem diameter (PSD) and the medullary canal diameter (MCD) at the proximal portion of the stem (level A), halfway along the stem length (level B), and distally at the stem tip (level C).


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 360 - 365
1 Feb 2021
Mahendraraj KA Shields MV Grubhofer F Golenbock SW Jawa A

Aims

Existing literature indicates that inferiorly inclined glenoid baseplates following reverse total shoulder arthroplasty (RSA) produce better outcomes compared to superiorly inclined baseplates. We aim to compare clinical outcomes for RSAs with superiorly and neutrally/inferiorly inclined lateralized glenospheres.

Methods

We retrospectively reviewed 154 consecutive patients undergoing RSA between July 2015 and July 2017 by one single-fellowship trained surgeon (AJ). Two raters (KAM and MVS) independently measured glenoid inclination in preoperative and minimum two year follow-up radiographs (anteroposterior/Grashey) using the RSA angle. Inclination was then compared to patient-reported outcomes, range of motion (ROM), and independently assessed degree of scapular notching and staging of heterotopic ossification at two year follow-up.


Bone & Joint Open
Vol. 2, Issue 1 | Pages 58 - 65
22 Jan 2021
Karssiens TJ Gill JR Sunil Kumar KH Sjolin SU

Aims

The Mathys Affinis Short is the most frequently used stemless total shoulder prosthesis in the UK. The purpose of this prospective cohort study is to report the survivorship, clinical, and radiological outcomes of the first independent series of the Affinis Short prosthesis.

Methods

From January 2011 to January 2019, a total of 141 Affinis Short prostheses were implanted in 127 patients by a single surgeon. Mean age at time of surgery was 68 (44 to 89). Minimum one year and maximum eight year follow-up (mean 3.7 years) was analyzed using the Oxford Shoulder Score (OSS) at latest follow-up. Kaplan-Meier survivorship analysis was performed with implant revision as the endpoint. Most recently performed radiographs were reviewed for component radiolucent lines (RLLs) and proximal humeral migration.


The Bone & Joint Journal
Vol. 102-B, Issue 11 | Pages 1555 - 1559
1 Nov 2020
Sebastia-Forcada E Lizaur-Utrilla A Mahiques-Segura G Ruiz-Lozano M Lopez-Prats FA Alonso-Montero C

Aims

The purpose of this study was to determine whether there were long-term differences in outcomes of reverse shoulder arthroplasty (RSA) undertaken for acute proximal humeral fracture versus rotator cuff deficiency with a minimum follow-up of five years.

Methods

This was a prospective cohort study comparing 67 patients with acute complex proximal humeral fracture and 64 patients with irreparable rotator cuff deficiency who underwent primary RSA. In the fracture group, there were 52 (77.6%) females and 15 (22.4%) males, with a mean age of 73.5 years (51 to 85), while in the arthropathy group, there were 43 (67.1%) females and 21 (32.9%) males, with a mean age of 70.6 years (50 to 84). Patients were assessed by the Constant score, University of California Los Angeles shoulder score (UCLA), short version of the Disability of the Arm Shoulder and Hand score (QuickDASH), and visual analogue scales (VAS) for pain and satisfaction. Radiological evaluation was also performed.


The Bone & Joint Journal
Vol. 102-B, Issue 9 | Pages 1194 - 1199
14 Sep 2020
Lee H Kim E Kim Y

Aims

The purpose of this study was to identify the changes in untreated long head of the biceps brachii tendon (LHBT) after a rotator cuff tear and to evaluate the factors related to the changes.

Methods

A cohort of 162 patients who underwent isolated supraspinatus with the preservation of LHBT was enrolled and evaluated. The cross-sectional area (CSA) of the LHBT on MRI was measured in the bicipital groove, and preoperative to postoperative difference was calculated at least 12 months postoperatively. Second, postoperative changes in the LHBT including intratendinous signal change, rupture, dislocation, or superior labral lesions were evaluated with seeking of factors that were correlated with the changes or newly developed lesions after rotator cuff repair.


Bone & Joint Open
Vol. 1, Issue 7 | Pages 376 - 382
10 Jul 2020
Gill JR Vermuyten L Schenk SA Ong JCY Schenk W

Aims

The aim of this study is to report the results of a case series of olecranon fractures and olecranon osteotomies treated with two bicortical screws.

Methods

Data was collected retrospectively for all olecranon fractures and osteotomies fixed with two bicortical screws between January 2008 and December 2019 at our institution. The following outcome measures were assessed; re-operation, complications, radiological loss of reduction, and elbow range of flexion-extension.


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1280 - 1284
1 Oct 2019
Kang JR Logli AL Tagliero AJ Sperling JW

Aims

A number of methods have been described to remove a well-fixed humeral implant as part of revision shoulder arthroplasty. These include the use of cortical windows and humeral osteotomies. The router bit extraction technique uses a high-speed router bit to disrupt the bone-implant interface. The implant is then struck in a retrograde fashion with a square-tip impactor and mallet. The purpose of this study was to determine the characteristics and frequency of the different techniques needed for the removal of a well-fixed humeral stem in revision shoulder arthroplasty.

Patients and Methods

Between 2010 and 2018, 288 revision shoulder arthroplasty procedures requiring removal of a well-fixed humeral component were carried out at a tertiary referral centre by a single surgeon. The patient demographics, indications for surgery, and method of extraction were collected.


The Bone & Joint Journal
Vol. 101-B, Issue 9 | Pages 1107 - 1114
1 Sep 2019
Uy M Wang J Horner NS Bedi A Leroux T Alolabi B Khan M

Aims

The aim of this study was to evaluate the differences in revision and complication rates, functional outcomes, and radiological outcomes between cemented and press-fit humeral stems in primary anatomical total shoulder arthroplasty (TSA).

Materials and Methods

A comprehensive systematic review and meta-analysis was conducted searching for studies that included patients who underwent primary anatomical TSA for primary osteoarthritis or rheumatoid arthritis.


The Bone & Joint Journal
Vol. 101-B, Issue 9 | Pages 1100 - 1106
1 Sep 2019
Schemitsch C Chahal J Vicente M Nowak L Flurin P Lambers Heerspink F Henry P Nauth A

Aims

The purpose of this study was to compare the effectiveness of surgical repair to conservative treatment and subacromial decompression for the treatment of chronic/degenerative tears of the rotator cuff.

Materials and Methods

PubMed, Cochrane database, and Medline were searched for randomized controlled trials published until March 2018. Included studies were assessed for methodological quality, and data were extracted for statistical analysis. The systematic review was conducted following PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines.


Bone & Joint Research
Vol. 8, Issue 8 | Pages 357 - 366
1 Aug 2019
Lädermann A Tay E Collin P Piotton S Chiu C Michelet A Charbonnier C

Objectives

To date, no study has considered the impact of acromial morphology on shoulder range of movement (ROM). The purpose of our study was to evaluate the effects of lateralization of the centre of rotation (COR) and neck-shaft angle (NSA) on shoulder ROM after reverse shoulder arthroplasty (RSA) in patients with different scapular morphologies.

Methods

3D computer models were constructed from CT scans of 12 patients with a critical shoulder angle (CSA) of 25°, 30°, 35°, and 40°. For each model, shoulder ROM was evaluated at a NSA of 135° and 145°, and lateralization of 0 mm, 5 mm, and 10 mm for seven standardized movements: glenohumeral abduction, adduction, forward flexion, extension, internal rotation with the arm at 90° of abduction, as well as external rotation with the arm at 10° and 90° of abduction.


The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 603 - 609
1 May 2019
Aagaard KE Lunsjö K Frobell R

Aims

Failure of healing is a well-known problem after repair of the rotator cuff. This study aimed to investigate if early repair of trauma-related full-thickness rotator cuff tears (FTRCTs) could prevent this failure.

Patients and Methods

In this prospective trial, 62 consecutive patients (14 women (23%), 48 men (77%); median age 61 years (interquartile range (IQR) 54 to 65)) with trauma-related FTRCT underwent arthroscopic single-row repair within six weeks of trauma. Tendon integrity was assessed one year after surgery using the Sugaya score on MR images. Patients were followed up with Western Ontario Rotator Cuff (WORC) index, EuroQol visual analogue scale (EQ VAS), and the Constant–Murley score (CS) two years after repair.


The Bone & Joint Journal
Vol. 100-B, Issue 12 | Pages 1609 - 1617
1 Dec 2018
Malhas AM Granville-Chapman J Robinson PM Brookes-Fazakerley S Walton M Monga P Bale S Trail I

Aims

We present our experience of using a metal-backed prosthesis and autologous bone graft to treat gross glenoid bone deficiency.

Patients and Methods

A prospective cohort study of the first 45 shoulder arthroplasties using the SMR Axioma Trabecular Titanium (TT) metal-backed glenoid with autologous bone graft. Between May 2013 and December 2014, 45 shoulder arthroplasties were carried out in 44 patients with a mean age of 64 years (35 to 89). The indications were 23 complex primary arthroplasties, 12 to revise a hemiarthroplasty or resurfacing, five for aseptic loosening of the glenoid, and five for infection.


The Bone & Joint Journal
Vol. 100-B, Issue 11 | Pages 1493 - 1498
1 Nov 2018
Wagner ER Hevesi M Houdek MT Cofield RH Sperling JW Sanchez-Sotelo J

Aims

Patients with a failed reverse shoulder arthroplasty (RSA) have limited salvage options. The aim of this study was to determine the outcome of revision RSA when used as a salvage procedure for a failed primary RSA.

Patients and Methods

We reviewed all revision RSAs performed for a failed primary RSA between 2006 and 2012, excluding patients with a follow-up of less than two years. A total of 27 revision RSAs were included in the study. The mean age of the patients at the time of revision was 70 years (58 to 82). Of the 27 patients, 14 (52% were female). The mean follow-up was 4.4 years (2 to 10).


The Bone & Joint Journal
Vol. 100-B, Issue 11 | Pages 1499 - 1505
1 Nov 2018
Mazhar FN Ebrahimi H Jafari D Mirzaei A

Aims

The crucial role of the radial head in the stability of the elbow in terrible triad injury is acknowledged. This retrospective study aims to compare the results of resection of a severely comminuted radial head with or without prosthetic arthroplasty as part of the reconstruction for this injury.

Patients and Methods

The outcome of radial head resection was compared with prosthetic arthroplasty in 29 and 15 patients with terrible triad injuries, respectively. There were ten female patients (34.5%) in the resection group and six female patients (40%) in the prosthesis group. The mean age was 40.7 years (sd 13.6) in the resection group and 36 years (sd 9.4) in the prosthesis group. The mean follow-up of the patients was 24.4 months (sd 12) in the resection group and 45.8 months (sd 6.8) in the prosthesis group. Outcome measures included visual analogue scale (VAS) for pain, Mayo Elbow Performance Score (MEPS), Disabilities of Arm, Shoulder and Hand (DASH) Score, and range of movement. Postoperative radiological complications were also recorded.


The Bone & Joint Journal
Vol. 100-B, Issue 7 | Pages 953 - 956
1 Jul 2018
Erşen A Atalar AC Bayram S Demirel M Tunalı O Demirhan M

Aims

The present study aimed to investigate the long-term functional results of scapulothoracic fusion using multifilament cables in patients with facioscapulohumeral dystrophy (FSHD) to identify if the early improvement from this intervention is maintained.

Patients and Methods

We retrospectively investigated the long-term outcomes of 13 patients with FSHD (18 shoulders) in whom scapulothoracic fusion using multifilament cables was performed between 2004 and 2007. These patients have previously been reported at a mean of 35.5 months (24 to 87). There were eight men and five women with a mean age of 26 years. Their mean length of follow-up of our current study was 128 months (94 to 185). To evaluate long-term functional results, the range of shoulder flexion and abduction, Quick Disabilities of the Arm, Shoulder and Hand (QuickDASH) scores were analyzed with a comparison of preoperatively, interim and at the final outcomes. The fusion was examined radiographically in all.


The Bone & Joint Journal
Vol. 100-B, Issue 8 | Pages 1066 - 1073
1 Aug 2018
Nishida K Hashizume K Nasu Y Ozawa M Fujiwara K Inoue H Ozaki T

Aims

The aim of this study was to report the mid-term clinical outcome of cemented unlinked J-alumina ceramic elbow (JACE) arthroplasties when used in patients with rheumatoid arthritis (RA).

Patients and Methods

We retrospectively reviewed 87 elbows, in 75 patients with RA, which was replaced using a cemented JACE total elbow arthroplasty (TEA) between August 2003 and December 2012, with a follow-up of 96%. There were 72 women and three men, with a mean age of 62 years (35 to 79). The mean follow-up was nine years (2 to 14). The clinical condition of each elbow before and after surgery was assessed using the Mayo Elbow Performance Index (MEPI, 0 to 100 points). Radiographic loosening was defined as a progressive radiolucent line of >1 mm that was completely circumferential around the prosthesis.


The Bone & Joint Journal
Vol. 100-B, Issue 5 | Pages 610 - 616
1 May 2018
Giannicola G Bullitta G Rotini R Murena L Blonna D Iapicca M Restuccia G Merolla G Fontana M Greco A Scacchi M Cinotti G

Aims

The aim of the study was to analyze the results of primary tendon reinsertion in acute and chronic distal triceps tendon ruptures (DTTRs) in the general population.

Patients and Methods

A total of 28 patients were operated on for primary DTTR reinsertions, including 21 male patients and seven female patients with a mean age of 45 years (14 to 76). Of these patients, 23 sustained an acute DTTR and five had a chronic injury. One patient had a non-simultaneous bilateral DTTR. Seven patients had DTTR-associated ipsilateral fracture or dislocation. Comorbidities were present in four patients. Surgical treatment included transosseous and suture-anchors reinsertion in 22 and seven DTTRs, respectively. The clinical evaluation was performed using Mayo Elbow Performance Score (MEPS), the modified American Shoulder and Elbow Surgeons Score (m-ASES), the Quick Disabilities of the Arm, Shoulder and Hand score (QuickDASH), and the Medical Research Council (MRC) Scale.


The Bone & Joint Journal
Vol. 100-B, Issue 6 | Pages 761 - 766
1 Jun 2018
Holschen M Siemes M Witt K Steinbeck J

Aims

The reasons for failure of a hemirthroplasty (HA) when used to treat a proximal humeral fracture include displaced or necrotic tuberosities, insufficient metaphyseal bone-stock, and rotator cuff tears. Reverse total shoulder arthroplasty (rTSA) is often the only remaining form of treatment in these patients. The aim of this study was to evaluate the clinical outcome after conversions from a failed HA to rTSA.

Material and Methods

A total of 35 patients, in whom a HA, as treatment for a fracture of the proximal humerus, had failed, underwent conversion to a rTSA. A total of 28 were available for follow-up at a mean of 61 months (37 to 91), having been initially reviewed at a mean of 20 months (12 to 36) postoperatively. Having a convertible design, the humeral stem could be preserved in nine patients. The stem was removed in the other 19 patients and a conventional rTSA was implanted. At final follow-up, patients were assessed using the American Shoulder and Elbow Surgeons (ASES) score, the Constant Score, and plain radiographs.


The Bone & Joint Journal
Vol. 100-B, Issue 3 | Pages 324 - 330
1 Mar 2018
Mahure SA Mollon B Capogna BM Zuckerman JD Kwon YW Rokito AS

Aims

The factors that predispose to recurrent instability and revision stabilization procedures after arthroscopic Bankart repair for anterior glenohumeral instability remain unclear. We sought to determine the rate and risk factors associated with ongoing instability in patients undergoing arthroscopic Bankart repair for instability of the shoulder.

Materials and Methods

We used the Statewide Planning and Research Cooperative System (SPARCS) database to identify patients with a diagnosis of anterior instability of the shoulder undergoing arthroscopic Bankart repair between 2003 and 2011. Patients were followed for a minimum of three years. Baseline demographics and subsequent further surgery to the ipsilateral shoulder were analyzed. Multivariate analysis was used to identify independent risk factors for recurrent instability.


The Bone & Joint Journal
Vol. 100-B, Issue 3 | Pages 309 - 317
1 Mar 2018
Kolk A Henseler JF Overes FJ Nagels J Nelissen RGHH

Aims

Since long-term outcome of teres major tendon transfer surgery for irreparable posterosuperior rotator cuff (RC) tears is largely unknown, the primary aim of this study was to evaluate the long-term outcome of the teres major transfer. We also aimed to report on the results of a cohort of patients with a similar indication for surgery that underwent a latissimus dorsi tendon transfer.

Patients and Methods

In this prospective cohort study, we reported on the long-term results of 20 consecutive patients with a teres major tendon transfer for irreparable massive posterosuperior RC tears. Additionally, we reported on the results of the latissimus dorsi tendon transfer (n = 19). The mean age was 60 years (47 to 77). Outcomes included the Constant score (CS), and pain at rest and during movement using the Visual Analogue Scale (VAS).


The Bone & Joint Journal
Vol. 100-B, Issue 5 | Pages 603 - 609
1 May 2018
Schnetzke M Rick S Raiss P Walch G Loew M

Aims

The aim of this study was to evaluate the clinical and radiological outcome of using an anatomical short-stem shoulder prosthesis to treat primary osteoarthritis of the glenohumeral joint.

Patients and Methods

A total of 66 patients (67 shoulders) with a mean age of 76 years (63 to 92) were available for clinical and radiological follow-up at two different timepoints (T1, mean 2.6 years, sd 0.5; T2, mean 5.3 years, sd 0.7). Postoperative radiographs were analyzed for stem angle, cortical contact, and filling ratio of the stem. Follow-up radiographs were analyzed for timing and location of bone adaptation (cortical bone narrowing, osteopenia, spot welds, and condensation lines). The bone adaptation was classified as low (between zero and three features of bone remodelling around the humeral stem) or high (four or more features).


The Bone & Joint Journal
Vol. 100-B, Issue 3 | Pages 318 - 323
1 Mar 2018
Raiss P Alami G Bruckner T Magosch P Habermeyer P Boileau P Walch G

Aims

The aim of this study was to analyze the results of reverse shoulder arthroplasty (RSA) in patients with type 1 sequelae of a fracture of the proximal humerus in association with rotator cuff deficiency or severe stiffness of the shoulder.

Patients and Methods

A total of 38 patients were included: 28 women and ten men. Their mean age at the time of arthroplasty was 73 years (54 to 91). Before the RSA, 18 patients had been treated with open reduction and internal fixation following a fracture. A total of 22 patients had a rotator cuff tear and 11 had severe stiffness of the shoulder with < 0° of external rotation. The mean follow-up was 4.3 years (1.5 to 10). The Constant score and the range of movement of the shoulder were recorded preoperatively and at final follow-up.

Preoperatively, radiographs in two planes were performed, as well as CT or arthro-CT scans; radiographs were also performed at final follow-up.


The Bone & Joint Journal
Vol. 100-B, Issue 3 | Pages 331 - 337
1 Mar 2018
Inui H Nobuhara K

Aims

We report the clinical results of glenoid osteotomy in patients with atraumatic posteroinferior instability associated with glenoid dysplasia.

Patients and Methods

The study reports results in 211 patients (249 shoulders) with atraumatic posteroinferior instability. The patients comprised 63 men and 148 women with a mean age of 20 years. The posteroinferior glenoid surface was elevated by osteotomy at the scapular neck. A body spica was applied to maintain the arm perpendicular to the glenoid for two weeks postoperatively. Clinical results were evaluated using the Rowe score and Japan Shoulder Society Shoulder Instability Score (JSS-SIS); bone union, osteoarthrosis, and articular congruity were examined on plain radiographs.


The Bone & Joint Journal
Vol. 99-B, Issue 9 | Pages 1197 - 1203
1 Sep 2017
Laumonerie P Reina N Ancelin D Delclaux S Tibbo ME Bonnevialle N Mansat P

Aims

Radial head arthroplasty (RHA) may be used in the treatment of non-reconstructable radial head fractures. The aim of this study was to evaluate the mid-term clinical and radiographic results of RHA.

Patients and Methods

Between 2002 and 2014, 77 RHAs were implanted in 54 men and 23 women with either acute injuries (54) or with traumatic sequelae (23) of a fracture of the radial head. Four designs of RHA were used, including the Guepar (Small Bone Innovations (SBi)/Stryker; 36), Evolutive (Aston Medical; 24), rHead RECON (SBi/Stryker; ten) or rHead STANDARD (SBi/Stryker; 7) prostheses. The mean follow-up was 74.0 months (standard deviation (sd) 38.6; 24 to 141). The indication for further surgery, range of movement, mean Mayo Elbow Performance (MEP) score, quick Disabilities of the Arm, Shoulder and Hand (quickDASH) score, osteolysis and positioning of the implant were also assessed according to the design, and acute or delayed use.


The Bone & Joint Journal
Vol. 99-B, Issue 5 | Pages 666 - 673
1 May 2017
Werthel J Lonjon G Jo S Cofield R Sperling JW Elhassan BT

Aims

In the initial development of total shoulder arthroplasty (TSA), the humeral component was usually fixed with cement. Cementless components were subsequently introduced. The aim of this study was to compare the long-term outcome of cemented and cementless humeral components in arthroplasty of the shoulder.

Patients and Methods

All patients who underwent primary arthroplasty of the shoulder at our institution between 1970 and 2012 were included in the study. There were 4636 patients with 1167 cemented humeral components and 3469 cementless components. Patients with the two types of fixation were matched for nine different covariates using a propensity score analysis. A total of 551 well-balanced pairs of patients with cemented and cementless components were available after matching for comparison of the outcomes. The clinical outcomes which were analysed included loosening of the humeral component determined at revision surgery, periprosthetic fractures, post-operative infection and operating time.


The Bone & Joint Journal
Vol. 99-B, Issue 8 | Pages 1073 - 1079
1 Aug 2017
Pauzenberger L Domej MA Heuberer PR Hexel M Grieb A Laky B Blasl J Anderl W

Aims

The purpose of the present study was to evaluate the impact of intravenous tranexamic acid on the reduction of blood loss, transfusion rate, and early post-operative clinical outcome in total shoulder arthroplasty.

Patients and Methods

A randomised, placebo-controlled trial which included 54 patients undergoing unilateral primary stemless anatomical or stemmed reverse total shoulder arthroplasty was undertaken. Patients received either 100 ml saline (placebo, n = 27), or 100 ml saline together with 1000 mg of tranexamic acid (TXA, n = 27) intravenously prior to skin incision and during wound closure. Peri-operative blood loss via an intra-articular drain was recorded and total blood loss was calculated. The post-operative transfusion rate was documented. Assessment of early clinical parameters included the visual analogue scale for pain (VAS), documentation of haematoma formation and adverse events.


The Bone & Joint Journal
Vol. 99-B, Issue 7 | Pages 934 - 938
1 Jul 2017
Basques BA Erickson BJ Leroux T Griffin JW Frank RM Verma NN Romeo AA

Aims

The aim of the present study was to compare the 30- and 90-day re-admission rates and complication rates of outpatient and inpatient total shoulder arthroplasty (TSA).

Patients and Methods

The United States Medicare Standard Analytical Files database was questioned to identify patients who had undergone outpatient or inpatient TSA between 2005 and 2012. Patient characteristics were compared between the two groups using chi-squared analysis. Multivariate logistic regression analysis was used to control for differences in baseline patient characteristics and to compare the two groups in terms of post-operative complications within 90 days and re-admission within 30 days and 90 days.


The Bone & Joint Journal
Vol. 99-B, Issue 6 | Pages 818 - 823
1 Jun 2017
Kodama A Mizuseki T Adachi N

Aims

We assessed the long-term (more than ten-year) outcomes of the Kudo type-5 elbow prosthesis in patients with rheumatoid arthritis (RA).

Materials and Methods

We reviewed 41 elbows (Larsen Grade IV, n = 21; Grade V, n = 20) in 31 patients with RA who had undergone a Kudo type-5 total elbow arthroplasty (TEA) between 1994 and 2003, and had been followed up for more than ten years. The humeral component was cementless and the all-polyethylene ulnar component cemented in every patient. Clinical outcome was assessed using the Mayo elbow performance score. We calculated the revision rate and evaluated potential risk factors for revision. The duration of follow-up was a mean 141 months (120 to 203).


The Bone & Joint Journal
Vol. 99-B, Issue 5 | Pages 674 - 679
1 May 2017
Nuttall D Birch A Haines JF Watts AC Trail IA

Aims

Radiostereometric analysis (RSA) allows an extremely accurate measurement of early micromotion of components following arthroplasty.

Patients and Methods

In this study, RSA was used to measure the migration of 11 partially cemented fluted pegged glenoid components in patients with osteoarthritis who underwent total shoulder arthroplasty using an improved surgical technique (seven men, four women, mean age 68). Patients were evaluated clinically using the American Shoulder and Elbow Surgeons (ASES) and Constant-Murley scores and by CT scans two years post-operatively.


The Bone & Joint Journal
Vol. 99-B, Issue 2 | Pages 245 - 249
1 Feb 2017
Barnes LAF Kim HM Caldwell J Buza J Ahmad CS Bigliani LU Levine WN

Aims

Advances in arthroscopic techniques for rotator cuff repair have made the mini-open approach less popular. However, the mini-open approach remains an important technique for repair for many surgeons. The aims of this study were to compare the integrity of the repair, the function of the shoulder and satisfaction post-operatively using these two techniques in patients aged > 50 years.

Patients and Methods

We identified 22 patients treated with mini-open and 128 patients treated with arthroscopic rotator cuff repair of July 2007 and June 2011. The mean follow-up was two years (1 to 5). Outcome was assessed using the American Shoulder and Elbow Surgeons (ASES) and Simple Shoulder Test (SST) scores, and satisfaction. The integrity of the repair was assessed using ultrasonography. A power analysis ensured sufficient enrolment.


The Bone & Joint Journal
Vol. 98-B, Issue 12 | Pages 1656 - 1661
1 Dec 2016
Kim S Park J Lee K Lee B

Aims

The aim of the study was to develop a quantitative scoring system to predict whether a large-to-massive rotator cuff tear was arthroscopically reparable prior to surgery.

Patients and Methods

We conducted a retrospective review of the pre-operative MR imaging and surgical records of 87 patients (87 shoulders) who underwent arthroscopic repair of a large-to-massive rotator cuff tear. Patients were divided into two groups, based on the surgical outcome of the repair. Of the 87 patients, 53 underwent complete repair (Group I) and 34 an incomplete repair (Group II). Pre-operative MR images were reviewed to quantify several variables. Between-group differences were evaluated and multiple logistic regression analysis was used to calculate the predictive value of significant variables. The reparability index (RI) was constructed using the odds ratios of significant variables and a receiver operating characteristic curve analysis performed to identify the optimal RI cutoff to differentiate between the two groups.


The Bone & Joint Journal
Vol. 98-B, Issue 4 | Pages 504 - 511
1 Apr 2016
Ajami S Blunn GW Lambert S Alexander S Foxall Smith M Coathup MJ

Aims

To assess the extent of osteointegration in two designs of shoulder resurfacing implants. Bony integration to the Copeland cylindrical central stem design and the Epoca RH conical-crown design were compared.

Patients and Methods

Implants retrieved from six patients in each group were pair-matched. Mean time to revision surgery of Copeland implants was 37 months (standard deviation (sd) 23; 14 to 72) and Epoca RH 38 months (sd 28; 12 to 84). The mean age of patients investigated was 66 years (sd 4; 59 to 71) and 58 years (sd 17; 31 to 73) in the Copeland and Epoca RH groups respectively. None of these implants were revised for loosening.


The Bone & Joint Journal
Vol. 98-B, Issue 3 | Pages 374 - 380
1 Mar 2016
Kocsis G Thyagarajan DS Fairbairn KJ Wallace WA

Aims

Glenoid bone loss can be a challenging problem when revising a shoulder arthroplasty. Precise pre-operative planning based on plain radiographs or CT scans is essential. We have investigated a new radiological classification system to describe the degree of medialisation of the bony glenoid and that will indicate the amount of bone potentially available for supporting a glenoid component. It depends on the relationship between the most medial part of the articular surface of the glenoid with the base of the coracoid process and the spinoglenoid notch: it classifies the degree of bone loss into three types.

It also attempts to predict the type of glenoid reconstruction that may be possible (impaction bone grafting, structural grafting or simple non-augmented arthroplasty) and gives guidance about whether a pre-operative CT scan is indicated.

Patients and Methods

Inter-method reliability between plain radiographs and CT scans was assessed retrospectively by three independent observers using data from 39 randomly selected patients.

Inter-observer reliability and test-retest reliability was tested on the same cohort using Cohen's kappa statistics. Correlation of the type of glenoid with the Constant score and its pain component was analysed using the Kruskal-Wallis method on data from 128 patients. Anatomical studies of the scapula were reviewed to explain the findings.


The Bone & Joint Journal
Vol. 98-B, Issue 2 | Pages 224 - 228
1 Feb 2016
Padegimas EM Clyde CT Zmistowski BM Restrepo C Williams GR Namdari S

Aims

Currently, there is little information about the need for peri-operative blood transfusion in patients undergoing shoulder arthroplasty.

The purpose of this study was to identify the rate of transfusion and its predisposing factors, and to establish a blood conservation strategy.

Methods

We identified all patients who had undergone shoulder arthroplasty at our hospital between 1 January 2011 and 31 December 2013. The rate of transfusion was determined from the patient’s records. While there were exceptions, patients typically underwent transfusion if they had a level of haemoglobin of < 7.5 g/dl if asymptomatic, < 9.0 g/dl if they had a significant cardiac history or symptoms of dizziness or light headedness.

Multivariable regression analysis was undertaken to identify predictors of transfusion. High- and low-risk cohorts for transfusion were identified from a receiver operating characteristic (ROC) curve.


The Bone & Joint Journal
Vol. 97-B, Issue 10 | Pages 1377 - 1384
1 Oct 2015
Nestorson J Ekholm C Etzner M Adolfsson L

We report our experience of performing an elbow hemiarthroplasty in the treatment of comminuted distal humeral fractures in the elderly patients.

A cohort of 42 patients (three men and 39 women, mean age 72; 56 to 84) were reviewed at a mean of 34.3 months (24 to 61) after surgery. Functional outcome was measured with the Mayo Elbow Performance Score (MEPS) and range of movement. The disabilities of the arm, shoulder and hand questionnaire (DASH) was used as a patient rated evaluation. Complications and ulnar nerve function were recorded. Plain radiographs were obtained to assess prosthetic loosening, olecranon wear and heterotopic bone formation.

The mean extension deficit was 23.5° (0° to 60°) and mean flexion was 126.8° (90° to 145°) giving a mean arc of 105.5° (60° to 145°). The mean MEPS was 90 (50 to 100) and a mean DASH score of 20 (0 to 63). Four patients had additional surgery for limited range of movement and one for partial instability. One elbow was revised due to loosening, two patients had sensory ulnar nerve symptoms, and radiographic signs of mild olecranon wear was noted in five patients.

Elbow hemiarthroplasty for comminuted intra-articular distal humeral fractures produces reliable medium-term results with functional outcome and complication rates, comparable with open reduction and internal fixation and total elbow arthroplasty.

Cite this article: Bone Joint J 2015;97-B:1377–84.


The Bone & Joint Journal
Vol. 98-B, Issue 1 | Pages 75 - 80
1 Jan 2016
Merolla G Chin P Sasyniuk TM Paladini P Porcellini G

Aims

We evaluated clinical and radiographic outcomes of total shoulder arthroplasty (TSA) using the second-generation Trabecular Metal (TM) Glenoid component. The first generation component was withdrawn in 2005 after a series of failures were reported. Between 2009 and 2012, 40 consecutive patients with unilateral TSA using the second-generation component were enrolled in this clinical study. The mean age of the patients was 63.8 years (40 to 75) and the mean follow-up was 38 months (24 to 42).

Methods

Patients were evaluated using the Constant score (CS), the American Shoulder and Elbow Surgeons (ASES) score and routine radiographs.


The Bone & Joint Journal
Vol. 97-B, Issue 12 | Pages 1657 - 1661
1 Dec 2015
Taranu R Rushton PRP Serrano-Pedraza I Holder L Wallace WA Candal-Couto JJ

Dislocation of the acromioclavicular joint is a relatively common injury and a number of surgical interventions have been described for its treatment. Recently, a synthetic ligament device has become available and been successfully used, however, like other non-native solutions, a compromise must be reached when choosing non-anatomical locations for their placement. This cadaveric study aimed to assess the effect of different clavicular anchorage points for the Lockdown device on the reduction of acromioclavicular joint dislocations, and suggest an optimal location. We also assessed whether further stability is provided using a coracoacromial ligament transfer (a modified Neviaser technique). The acromioclavicular joint was exposed on seven fresh-frozen cadaveric shoulders. The joint was reconstructed using the Lockdown implant using four different clavicular anchorage points and reduction was measured. The coracoacromial ligament was then transferred to the lateral end of the clavicle, and the joint re-assessed. If the Lockdown ligament was secured at the level of the conoid tubercle, the acromioclavicular joint could be reduced anatomically in all cases. If placed medial or 2 cm lateral, the joint was irreducible. If the Lockdown was placed 1 cm lateral to the conoid tubercle, the joint could be reduced with difficulty in four cases. Correct placement of the Lockdown device is crucial to allow anatomical joint reduction. Even when the Lockdown was placed over the conoid tubercle, anterior clavicle displacement remained but this could be controlled using a coracoacromial ligament transfer.

Cite this article: Bone Joint J 2015;97-B:1657–61.


The Bone & Joint Journal
Vol. 97-B, Issue 7 | Pages 967 - 972
1 Jul 2015
Hussey MM Hussey SE Mighell MA

Failed internal fixation of a fracture of the proximal humerus produces many challenges with limited surgical options. The aim of this study was to evaluate the clinical outcomes after the use of a reverse shoulder arthroplasty under these circumstances. Between 2007 and 2012, 19 patients (15 women and four men, mean age 66 years; 52 to 82) with failed internal fixation after a proximal humeral fracture, underwent implant removal and reverse shoulder arthroplasty (RSA). The mean follow-up was 36 months (25 to 60). The mean American Shoulder and Elbow Score improved from 27.8 to 50.1 (p = 0.019). The mean Simple Shoulder Test score improved from 0.7 to 3.2 (p = 0.020), and the mean visual analogue scale for pain improved from 6.8 to 4.3 (p = 0.012). Mean forward flexion improved from 58.7° to 101.1° (p < 0.001), mean abduction from 58.7° to 89.1° (p = 0.012), mean external rotation from 10.7° to 23.1° (p = 0.043) and mean internal rotation from buttocks to L4 (p = 0.034). A major complication was recorded in five patients (26%) (one intra-operative fracture, loosening of the humeral component in two and two peri-prosthetic fractures). A total of 15 patients (79%) rated their outcome as excellent or good, one (5%) as satisfactory, and three (16%) as unsatisfactory.

An improvement in outcomes and pain can be expected when performing a RSA as a salvage procedure after failed internal fixation of a fracture of the proximal humerus. Patients should be cautioned about the possibility for major complications following this technically demanding procedure.

Cite this article: Bone Joint J 2015;97-B:967–72.


The Bone & Joint Journal
Vol. 97-B, Issue 5 | Pages 681 - 688
1 May 2015
Wagener ML de Vos MJ Hannink G van der Pluijm M Verdonschot N Eygendaal D

Unlinked, linked and convertible total elbow arthroplasties (TEAs) are currently available. This study is the first to report the clinical results of the convertible Latitude TEA. This was a retrospective study of a consecutive cohort of 63 patients (69 primary TEAs) with a mean age of 60 years (23 to 87). Between 2006 and 2008 a total of 19 men and 50 women underwent surgery. The mean follow-up was 43 months (8 to 84). The range of movement, function and pain all improved six months post-operatively and either continued to improve slightly or reached a plateau thereafter. The complication rate is similar to that reported for other TEA systems. No loosening was seen. Remarkable is the disengagement of the radial head component in 13 TEAs (31%) with a radial head component implanted.

Implantation of both the linked and the unlinked versions of the Latitude TEA results in improvement of function and decreased pain, and shows high patient satisfaction at mid-term follow-up.

Cite this article: Bone Joint J 2015; 97-B:681–8.


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1090 - 1095
1 Aug 2015
Urita A Funakoshi T Suenaga N Oizumi N Iwasaki N

This pilot study reports the clinical outcomes of a combination of partial subscapularis tendon transfer and small-head hemiarthroplasty in patients with rotatator cuff arthropathy. A total of 30 patients (30 shoulders; eight men and 22 women) with a mean age of 74 years (55 to 84) were assessed at a mean follow-up of 31 months (24 to 60). The inclusion criteria were painful cuff tear arthropathy with normal deltoid function and a non-degenerative subscapularis muscle and tendon and a preserved teres minor.

Outcome was assessed using the University of California Los Angeles score, the Japanese Orthopaedic Association score, and the Oxford Shoulder Score. Radiographic measurements included the centre of rotation distance and the length of the deltoid.

All clinical scores were significantly improved post-operatively. The active flexion and external rotation improved significantly at the most recent follow-up (p < 0.035). Although the mean centre of rotation distance changed significantly (p < 0.001), the mean length of the deltoid did not change significantly from the pre-operative value (p = 0.29). The change in the length of the deltoid with < 100° flexion was significantly less than that with > 100° (p < 0.001).

Progressive erosion of the glenoid was seen in four patients. No patient required revision or further surgery.

A combination of partial subscapularis tendon transfer and small-head hemiarthroplasty effectively restored function and relieved pain in patients with rotator cuff arthropathy.

Cite this article: 2015;97-B:1090–5.


The Bone & Joint Journal
Vol. 96-B, Issue 12 | Pages 1681 - 1687
1 Dec 2014
Foruria AM Lawrence TM Augustin S Morrey BF Sanchez-Sotelo J

We retrospectively reviewed 89 consecutive patients (45 men and 44 women) with a mean age at the time of injury of 58 years (18 to 97) who had undergone external fixation after sustaining a unilateral fracture of the distal humerus. Our objectives were to determine the incidence of heterotopic ossification (HO); identify risk factors associated with the development of HO; and characterise the location, severity and resultant functional impairment attributable to the presence of HO.

HO was identified in 37 elbows (42%), mostly around the humerus and along the course of the medial collateral ligament. HO was hazy immature in five elbows (13.5%), mature discrete in 20 (54%), extensive mature in 10 (27%), and complete bone bridges were present in two elbows (5.5%). Mild functional impairment occurred in eight patients, moderate in 27 and severe in two. HO was associated with less extension (p = 0.032) and less overall flexion-to-extension movement (p = 0.022); the flexion-to-extension arc was < 100º in 21 elbows (57%) with HO compared with 18 elbows (35%) without HO (p = 0.03). HO was removed surgically in seven elbows.

The development of HO was significantly associated with sustaining a head injury (p = 0.015), delayed internal fixation (p = 0.027), the method of fracture fixation (p = 0.039) and the use of bone graft or substitute (p = 0.02).HO continues to be a substantial complication after internal fixation for distal humerus fractures.

Cite this article: Bone Joint J 2014;96-B:1681–7.


The Bone & Joint Journal
Vol. 96-B, Issue 11 | Pages 1525 - 1529
1 Nov 2014
Thangarajah T Alexander S Bayley I Lambert SM

We report our experience with glenohumeral arthrodesis as a salvage procedure for epilepsy-related recurrent shoulder instability. A total of six patients with epilepsy underwent shoulder fusion for recurrent instability and were followed up for a mean of 39 months (12 to 79). The mean age at the time of surgery was 31 years (22 to 38). Arthrodesis was performed after a mean of four previous stabilisation attempts (0 to 11) in all but one patient in whom the procedure was used as a primary treatment. All patients achieved bony union, with a mean time to fusion of 2.8 months (2 to 7). There were no cases of re-dislocation. One revision was undertaken for loosening of the metalwork, and then healed satisfactorily. An increase was noted in the mean subjective shoulder value, which improved from 37 (5 to 50) pre-operatively to 42 (20 to 70) post-operatively although it decreased in two patients. The mean Oxford shoulder instability score improved from 13 pre-operatively (7 to 21) to 24 post-operatively (13 to 36). In our series, glenohumeral arthrodesis eliminated recurrent instability and improved functional outcome. Fusion surgery should therefore be considered in this patient population. However, since the majority of patients are young and active, they should be comprehensively counselled pre-operatively given the functional deficit that results from the procedure.

Cite this article: Bone Joint J 2014;96-B:1525–9.


The Bone & Joint Journal
Vol. 96-B, Issue 10 | Pages 1359 - 1365
1 Oct 2014
Large R Tambe A Cresswell T Espag M Clark DI

Medium-term results of the Discovery elbow replacement are presented. We reviewed 51 consecutive primary Discovery total elbow replacements (TERs) implanted in 48 patients. The mean age of the patients was 69.2 years (49 to 92), there were 19 males and 32 females (37%:63%) The mean follow-up was 40.6 months (24 to 69). A total of six patients were lost to follow-up. Statistically significant improvements in range movement and Oxford Elbow Score were found (p < 0.001). Radiolucent lines were much more common in, and aseptic loosening was exclusive to, the humeral component. Kaplan–Meier survivorship at five years was 92.2% (95% CI 74.5% to 96.4%) for aseptic loosening. In four TERs, periprosthetic infection occurred resulting in failure. A statistically significant association between infection and increased BMI was found (p = 0.0268). Triceps failure was more frequent after the Mayo surgical approach and TER performed after previous trauma surgery. No failures of the implant were noted.

Our comparison shows that the Discovery has early clinical results that are similar to other semi-constrained TERs. We found continued radiological surveillance with particular focus on humeral lucency is warranted and has not previously been reported. Despite advances in the design of total elbow replacement prostheses, rates of complication remain high.

Cite this article: Bone Joint J 2014;96-B:1359–65


The Bone & Joint Journal
Vol. 96-B, Issue 7 | Pages 936 - 942
1 Jul 2014
Middleton C Uri O Phillips S Barmpagiannis K Higgs D Falworth M Bayley I Lambert S

Inherent disadvantages of reverse shoulder arthroplasty designs based on the Grammont concept have raised a renewed interest in less-medialised designs and techniques. The aim of this study was to evaluate the outcome of reverse shoulder arthroplasty (RSA) with the fully-constrained, less-medialised, Bayley–Walker prosthesis performed for the treatment of rotator-cuff-deficient shoulders with glenohumeral arthritis. A total of 97 arthroplasties in 92 patients (53 women and 44 men, mean age 67 years (standard deviation (sd) 10, (49 to 85)) were retrospectively reviewed at a mean follow-up of 50 months ((sd 25) (24 to 96)). The mean Oxford shoulder score and subjective shoulder value improved from 47 (sd 9) and 24 points (sd 18) respectively before surgery to 28 (sd 11) and 61 (sd 24) points after surgery (p <  0.001). The mean pain at rest decreased from 5.3 (sd 2.8) to 1.5 (sd 2.3) (p < 0.001). The mean active forward elevation and external rotation increased from 42°(sd 30) and 9° (sd 15) respectively pre-operatively to 78° (sd 39) and 24° (sd 17) post-operatively (p < 0.001). A total of 20 patients required further surgery for complications; 13 required revision of components. No patient developed scapular notching.

The Bayley–Walker prosthesis provides reliable pain relief and reasonable functional improvement for patients with symptomatic cuff-deficient shoulders. Compared with other designs of RSA, it offers a modest improvement in forward elevation, but restores external rotation to some extent and prevents scapular notching. A longer follow-up is required to assess the survival of the prosthesis and the clinical performance over time.

Cite this article: Bone Joint J 2014;96-B:936–42.


The Bone & Joint Journal
Vol. 96-B, Issue 4 | Pages 526 - 529
1 Apr 2014
Giuseffi SA Streubel P Sperling J Sanchez-Sotelo J

Short uncemented humeral stems can preserve humeral bone stock and facilitate revision surgery but may be prone to malalignment or loosening, especially when used in reverse total shoulder replacement (TSR). We undertook a retrospective review of 44 patients with a mean age of 76 years (59 to 92) who underwent primary reverse TSR with a short uncemented humeral stem. There were 29 females. The indications for joint replacement included cuff tear associated arthropathy (33), avascular necrosis (six), post-traumatic arthritis (two), and inflammatory arthritis (three). At a mean follow-up of 27 months (24 to 40), pain was rated as mild or none in 43 shoulders (97.7%). The mean active elevation improved from 54° (sd 20°) to 142° (sd 25°) and the mean active external rotation from 14° (sd 13°) to 45° (sd 9°). The outcome, as assessed by the modified Neer score, was excellent in 27 (61.3%), satisfactory in 15 (34.1%), and unsatisfactory in two shoulders (4.5%). Stems were well-positioned, without evidence of significant valgus or varus malalignment in 42 TSRs (95.5%). There was no radiological evidence of loosening of the humeral stem in any patient; 13 TSRs (29.5%) had evidence of proximal humeral remodelling and scapular notching was noted in three (6.8%).

Cite this article: Bone Joint J 2014;96-B:526–9.


Bone & Joint 360
Vol. 2, Issue 4 | Pages 35 - 35
1 Aug 2013
Tytherleigh-Strong G


The Bone & Joint Journal
Vol. 95-B, Issue 12 | Pages 1595 - 1602
1 Dec 2013
Modi CS Beazley J Zywiel MG Lawrence TM Veillette CJH

The aim of this review is to address controversies in the management of dislocations of the acromioclavicular joint. Current evidence suggests that operative rather than non-operative treatment of Rockwood grade III dislocations results in better cosmetic and radiological results, similar functional outcomes and longer time off work. Early surgery results in better functional and radiological outcomes with a reduced risk of infection and loss of reduction compared with delayed surgery.

Surgical options include acromioclavicular fixation, coracoclavicular fixation and coracoclavicular ligament reconstruction. Although non-controlled studies report promising results for arthroscopic coracoclavicular fixation, there are no comparative studies with open techniques to draw conclusions about the best surgical approach. Non-rigid coracoclavicular fixation with tendon graft or synthetic materials, or rigid acromioclavicular fixation with a hook plate, is preferable to fixation with coracoclavicular screws owing to significant risks of loosening and breakage.

The evidence, although limited, also suggests that anatomical ligament reconstruction with autograft or certain synthetic grafts may have better outcomes than non-anatomical transfer of the coracoacromial ligament. It has been suggested that this is due to better restoration horizontal and vertical stability of the joint.

Despite the large number of recently published studies, there remains a lack of high-quality evidence, making it difficult to draw firm conclusions regarding these controversial issues.

Cite this article: Bone Joint J 2013;95-B:1595–1602.


The Bone & Joint Journal
Vol. 95-B, Issue 9 | Pages 1158 - 1164
1 Sep 2013
Ahmad Z Siddiqui N Malik SS Abdus-Samee M Tytherleigh-Strong G Rushton N

Lateral epicondylitis, or ’tennis elbow’, is a common condition that usually affects patients between 35 and 55 years of age. It is generally self-limiting, but in some patients it may continue to cause persistent symptoms, which can be refractory to treatment. This review discusses the mechanism of disease, symptoms and signs, investigations, current management protocols and potential new treatments.

Cite this article: Bone Joint J 2013;95-B:1158–64.