Advertisement for orthosearch.org.uk
Results 1 - 37 of 37
Results per page:
The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 91 - 96
1 Jan 2022
Modi A Haque A Deore V Singh HP Pandey R

Aims. Long-term outcomes following the use of human dermal allografts in the treatment of symptomatic irreparable rotator cuff tears are not known. The aim of this study was to evaluate these outcomes, and to investigate whether this would be a good form of treatment in young patients in whom a reverse shoulder arthroplasty should ideally be avoided. Methods. This prospective study included 47 shoulders in 45 patients who underwent an open reconstruction of the rotator cuff using an interposition GraftJacket allograft to bridge irreparable cuff tears, between January 2007 and November 2011. The Oxford Shoulder Score (OSS), pain score, and range of motion (ROM) were recorded preoperatively and at one year and a mean of 9.1 years (7.0 to 12.5) postoperatively. Results. There was significant improvement in the mean OSS from 24.7 (SD 5.4) preoperatively to 42.0 (SD 6.3) at one year, and this improvement was maintained at 9.1 years (p < 0.001), with a score of 42.8 (SD 6.8). Similar significant improvements in the pain score were seen and maintained at the final follow-up from 6.1 (SD 1.6) to 2.1 (SD 2.3) (p < 0.001). There were also significant improvements in the ROM of the shoulder, and patient satisfaction was high. Conclusion. The use of an interposition human dermal allograft in patients with an irreparable rotator cuff tear leads to good outcomes that are maintained at a mean of nine years postoperatively. Cite this article: Bone Joint J 2022;104-B(1):91–96


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 663 - 667
1 Jun 2023
Youn S Rhee SM Cho S Kim C Lee J Rhee YG

Aims

The aim of this study was to investigate the outcomes of arthroscopic decompression of calcific tendinitis performed without repairing the rotator cuff defect.

Methods

A total of 99 patients who underwent treatment between December 2013 and August 2019 were retrospectively reviewed. Visual analogue scale (VAS) and American Shoulder and Elbow Surgeons (ASES) scores were reviewed pre- and postoperatively according to the location, size, physical characteristics, and radiological features of the calcific deposits. Additionally, the influence of any residual calcific deposits shown on postoperative radiographs was explored. The healing rate of the unrepaired cuff defect was determined by reviewing the 29 patients who had follow-up MRIs.


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 366 - 372
1 Feb 2021
Sun Z Li J Luo G Wang F Hu Y Fan C

Aims. This study aimed to determine the minimal detectable change (MDC), minimal clinically important difference (MCID), and substantial clinical benefit (SCB) under distribution- and anchor-based methods for the Mayo Elbow Performance Index (MEPI) and range of movement (ROM) after open elbow arthrolysis (OEA). We also assessed the proportion of patients who achieved MCID and SCB; and identified the factors associated with achieving MCID. Methods. A cohort of 265 patients treated by OEA were included. The MEPI and ROM were evaluated at baseline and at two-year follow-up. Distribution-based MDC was calculated with confidence intervals (CIs) reflecting 80% (MDC 80), 90% (MDC 90), and 95% (MDC 95) certainty, and MCID with changes from baseline to follow-up. Anchor-based MCID (anchored to somewhat satisfied) and SCB (very satisfied) were calculated using a five-level Likert satisfaction scale. Multivariate logistic regression of factors affecting MCID achievement was performed. Results. The MDC increased substantially based on selected CIs (MDC 80, MDC 90, and MDC 95), ranging from 5.0 to 7.6 points for the MEPI, and from 8.2° to 12.5° for ROM. The MCID of the MEPI were 8.3 points under distribution-based and 12.2 points under anchor-based methods; distribution- and anchor-based MCID of ROM were 14.1° and 25.0°. The SCB of the MEPI and ROM were 17.3 points and 43.4°, respectively. The proportion of the patients who attained anchor-based MCID for the MEPI and ROM were 74.0% and 94.7%, respectively; furthermore, 64.2% and 86.8% attained SCB. Non-dominant arm (p = 0.022), higher preoperative MEPI rating (p < 0.001), and postoperative visual analogue scale pain score (p < 0.001) were independent predictors of not achieving MCID for the MEPI, while atraumatic causes (p = 0.040) and higher preoperative ROM (p = 0.005) were independent risk factors for ROM. Conclusion. In patients undergoing OEA, the MCID for the increased MEPI is 12.2 points and 25° increased ROM. The SCB is 17.3 points and 43.3°, respectively. Future studies using the MEPI and ROM to assess OEA outcomes should report not only statistical significance but also clinical importance. Cite this article: Bone Joint J 2021;103-B(2):366–372


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 360 - 365
1 Feb 2021
Mahendraraj KA Shields MV Grubhofer F Golenbock SW Jawa A

Aims. Existing literature indicates that inferiorly inclined glenoid baseplates following reverse total shoulder arthroplasty (RSA) produce better outcomes compared to superiorly inclined baseplates. We aim to compare clinical outcomes for RSAs with superiorly and neutrally/inferiorly inclined lateralized glenospheres. Methods. We retrospectively reviewed 154 consecutive patients undergoing RSA between July 2015 and July 2017 by one single-fellowship trained surgeon (AJ). Two raters (KAM and MVS) independently measured glenoid inclination in preoperative and minimum two year follow-up radiographs (anteroposterior/Grashey) using the RSA angle. Inclination was then compared to patient-reported outcomes, range of motion (ROM), and independently assessed degree of scapular notching and staging of heterotopic ossification at two year follow-up. Results. Median postoperative inclination for each group was found to be -3.6° (interquartile range (IQR) -2.1 to -6.9) and 6.0° (3.2° to 10.1°) for the neutrally/inferiorly and superiorly inclined cohorts, respectively. Preoperative inclination was highly associated with postoperative inclination (p = 0.004). When comparing superiorly and neutrally/inferiorly inclined glenospheres, there were no differences in heterotopic ossification (p = 0.606), scapular notching (p = 0.367), American Shoulder and Elbow Surgeons score (p = 0.419), Single Assessment Numeric Evaluation (p = 0.417), Visual Analogue Scale (VAS) pain score (p = 0.290), forward elevation (p = 0.161), external rotation (p = 0.537), or internal rotation (p = 0.656). Conclusion. Compared to neutral and inferior inclination, up to 6° ± 3° of superior glenoid baseplate inclination on a lateralized RSA design produces no differences in postoperative ROM or patient-reported outcomes, and produces similar levels of scapular notching and heterotopic ossification. Additionally, the degree of preoperative inclination represents an important factor in surgical decision-making as it is strongly associated with postoperative inclination. It is important to note that the findings of this study are only reflective of lateralized RSA prostheses. Cite this article: Bone Joint J 2021;103-B(2):360–365


Bone & Joint Open
Vol. 4, Issue 1 | Pages 19 - 26
13 Jan 2023
Nishida K Nasu Y Hashizume K Okita S Nakahara R Saito T Ozaki T Inoue H

Aims

There are concerns regarding complications and longevity of total elbow arthroplasty (TEA) in young patients, and the few previous publications are mainly limited to reports on linked elbow devices. We investigated the clinical outcome of unlinked TEA for patients aged less than 50 years with rheumatoid arthritis (RA).

Methods

We retrospectively reviewed the records of 26 elbows of 21 patients with RA who were aged less than 50 years who underwent primary TEA with an unlinked elbow prosthesis. The mean patient age was 46 years (35 to 49), and the mean follow-up period was 13.6 years (6 to 27). Outcome measures included pain, range of motion, Mayo Elbow Performance Score (MEPS), radiological evaluation for radiolucent line and loosening, complications, and revision surgery with or without implant removal.


Bone & Joint Open
Vol. 5, Issue 7 | Pages 534 - 542
1 Jul 2024
Woods A Howard A Peckham N Rombach I Saleh A Achten J Appelbe D Thamattore P Gwilym SE

Aims

The primary aim of this study was to assess the feasibility of recruiting and retaining patients to a patient-blinded randomized controlled trial comparing corticosteroid injection (CSI) to autologous protein solution (APS) injection for the treatment of subacromial shoulder pain in a community care setting. The study focused on recruitment rates and retention of participants throughout, and collected data on the interventions’ safety and efficacy.

Methods

Participants were recruited from two community musculoskeletal treatment centres in the UK. Patients were eligible if aged 18 years or older, and had a clinical diagnosis of subacromial impingement syndrome which the treating clinician thought was suitable for treatment with a subacromial injection. Consenting patients were randomly allocated 1:1 to a patient-blinded subacromial injection of CSI (standard care) or APS. The primary outcome measures of this study relate to rates of recruitment, retention, and compliance with intervention and follow-up to determine feasibility. Secondary outcome measures relate to the safety and efficacy of the interventions.


Bone & Joint Open
Vol. 2, Issue 9 | Pages 773 - 784
1 Sep 2021
Rex SS Kottam L McDaid C Brealey S Dias J Hewitt CE Keding A Lamb SE Wright K Rangan A

Aims

This systematic review places a recently completed multicentre randomized controlled trial (RCT), UK FROST, in the context of existing randomized evidence for the management of primary frozen shoulder. UK FROST compared the effectiveness of pre-specified physiotherapy techniques with a steroid injection (PTSI), manipulation under anaesthesia (MUA) with a steroid injection, and arthroscopic capsular release (ACR). This review updates a 2012 review focusing on the effectiveness of MUA, ACR, hydrodilatation, and PTSI.

Methods

MEDLINE, Embase, PEDro, Science Citation Index, Clinicaltrials.gov, CENTRAL, and the World Health Organization (WHO) International Clinical Trials Registry were searched up to December 2018. Reference lists of included studies were screened. No language restrictions applied. Eligible studies were RCTs comparing the effectiveness of MUA, ACR, PTSI, and hydrodilatation against each other, or supportive care or no treatment, for the management of primary frozen shoulder.


The Bone & Joint Journal
Vol. 98-B, Issue 8 | Pages 1086 - 1092
1 Aug 2016
de Vos MJ Wagener ML Hannink G van der Pluijm M Verdonschot N Eygendaal D

Aims. Revision total elbow arthroplasty (TEA) is often challenging. The aim of this study was to report on the clinical and radiological results of revision arthroplasty of the elbow with the Latitude TEA. Patients and Methods. Between 2006 and 2010 we used the Latitude TEA for revision in 18 consecutive elbows (17 patients); mean age 53 years (28 to 80); 14 women. A Kudo TEA was revised in 15 elbows and a Souter-Strathclyde TEA in three. Stability, range of movement (ROM), visual analogue score (VAS) for pain and functional scores, Elbow Functional Assessment Scale (EFAS), the Functional Rating Index of Broberg and Morrey (FRIBM) and the Modified Andrews’ Elbow Scoring System (MAESS) were assessed pre-operatively and at each post-operative follow-up visit (six, 12 months and biennially thereafter). Radiographs were analysed for loosening, fractures and dislocation. The mean follow-up was 59 months (26 to 89). Results. The ROM of the elbow did not improve significantly. The mean EFAS and MAESS scores improved significantly six months post-operatively (18.6 points, standard deviation (. sd. ) 7.7; p = 0.03 and 28.8 points, . sd . 8.6; p = 0.006, respectively) and continued to improve slightly or reached a plateau. The mean pain scores at rest (Z = -3.2, p = 0.001) and during activity (Z = -3.2, p = 0.001), and stability (Z = -3.0, p = 0.003) improved significantly six months post-operatively. Thereafter scores continued to improve slightly or a plateau was reached. There were no signs of loosening. Conclusion. Revision surgery using the Latitude TEA results in improvement of functionality, reduced pain and better stability of the elbow. Improvement of ROM of the elbow should not be expected. Cite this article: Bone Joint J 2016;98-B:1086–92


The Bone & Joint Journal
Vol. 99-B, Issue 2 | Pages 245 - 249
1 Feb 2017
Barnes LAF Kim HM Caldwell J Buza J Ahmad CS Bigliani LU Levine WN

Aims. Advances in arthroscopic techniques for rotator cuff repair have made the mini-open approach less popular. However, the mini-open approach remains an important technique for repair for many surgeons. The aims of this study were to compare the integrity of the repair, the function of the shoulder and satisfaction post-operatively using these two techniques in patients aged > 50 years. Patients and Methods. We identified 22 patients treated with mini-open and 128 patients treated with arthroscopic rotator cuff repair of July 2007 and June 2011. The mean follow-up was two years (1 to 5). Outcome was assessed using the American Shoulder and Elbow Surgeons (ASES) and Simple Shoulder Test (SST) scores, and satisfaction. The integrity of the repair was assessed using ultrasonography. A power analysis ensured sufficient enrolment. Results. There was no statistically significant difference between the age, function, satisfaction, or pain scores (p > 0.05) of the two groups. The integrity of the repair and the mean SST scores were significantly better in the mini-open group (91% of mini-open repairs were intact versus 60% of arthroscopic repairs, p = 0.023; mean SST score 10.9 (standard deviation (. sd. ) 1.3) in the mini-open group; 8.9 (. sd. 3.5) in arthroscopic group; p = 0.003). The ASES scores were also higher in the mini-open group (mean ASES score 91.0 (. sd. 10.5) in mini-open group; mean 82.70 (. sd. 19.8) in the arthroscopic group; p = 0.048). Conclusion. The integrity of the repair and function of the shoulder were better after a mini-open repair than after arthroscopic repair of a rotator cuff tear in these patients. The functional difference did not translate into a difference in satisfaction. Mini-open rotator cuff repair remains a useful technique despite advances in arthroscopy. Cite this article: Bone Joint J 2017;99-B:245–9


The Bone & Joint Journal
Vol. 96-B, Issue 4 | Pages 530 - 534
1 Apr 2014
Gallucci GL Piuzzi NS Slullitel PAI Boretto JG Alfie VA Donndorff A De Carli P

We retrospectively evaluated the clinical and radiological outcomes of a consecutive cohort of patients aged > 70 years with a displaced fracture of the olecranon, which was treated non-operatively with early mobilisation. We identified 28 such patients (27 women) with a mean age of 82 years (71 to 91). The elbow was initially immobilised in an above elbow cast in 90° of flexion of the elbow for a mean of five days. The cast was then replaced by a sling. Active mobilisation was encouraged as tolerated. No formal rehabilitation was undertaken. At a mean follow-up of 16 months (12 to 26), the mean ranges of flexion and extension were 140° and 15° respectively. On a visual analogue scale of 1 (no pain) to 10, the mean pain score was 1 (0 to 8). Of the original 28 patients 22 developed nonunion, but no patients required surgical treatment. . We conclude that non-operative functional treatment of displaced olecranon fractures in the elderly gives good results and a high rate of satisfaction. . Cite this article: Bone Joint J 2014;96-B:530–4


The Bone & Joint Journal
Vol. 101-B, Issue 12 | Pages 1520 - 1525
1 Dec 2019
Clark NJ Samuelsen BT Alentorn-Geli E Assenmacher AT Cofield RH Sperling JW Sánchez-Sotelo J

Aims

Reverse shoulder arthroplasty (RSA) reliably improves shoulder pain and function for a variety of indications. However, the safety and efficacy of RSA in elderly patients is largely unknown. The purpose of this study was to report the mortality, morbidity, complications, reoperations, and outcomes of primary RSA in patients aged > 80 years.

Patients and Methods

Between 2004 and 2013, 242 consecutive primary RSAs were performed in patients aged > 80 years (mean 83.3 years (sd 3.1)). Of these, 53 were lost to follow-up before two years and ten had died within two years of surgery, leaving 179 for analysis of survivorship, pain, motion, and strength at a minimum of two years or until revision surgery. All 242 patients were considered for the analysis of 90-day, one-year, and overall mortality, medical complications (90-day and overall), surgical complications, and reoperations. The indications for surgery included rotator cuff arthropathy, osteoarthritis, fracture, the sequela of trauma, avascular necrosis, and rheumatoid arthritis. A retrospective review of the medical records was performed to collect all variables. Survivorship free of revision surgery was calculated at two and five years.


The Bone & Joint Journal
Vol. 101-B, Issue 9 | Pages 1100 - 1106
1 Sep 2019
Schemitsch C Chahal J Vicente M Nowak L Flurin P Lambers Heerspink F Henry P Nauth A

Aims

The purpose of this study was to compare the effectiveness of surgical repair to conservative treatment and subacromial decompression for the treatment of chronic/degenerative tears of the rotator cuff.

Materials and Methods

PubMed, Cochrane database, and Medline were searched for randomized controlled trials published until March 2018. Included studies were assessed for methodological quality, and data were extracted for statistical analysis. The systematic review was conducted following PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines.


The Bone & Joint Journal
Vol. 101-B, Issue 9 | Pages 1107 - 1114
1 Sep 2019
Uy M Wang J Horner NS Bedi A Leroux T Alolabi B Khan M

Aims

The aim of this study was to evaluate the differences in revision and complication rates, functional outcomes, and radiological outcomes between cemented and press-fit humeral stems in primary anatomical total shoulder arthroplasty (TSA).

Materials and Methods

A comprehensive systematic review and meta-analysis was conducted searching for studies that included patients who underwent primary anatomical TSA for primary osteoarthritis or rheumatoid arthritis.


The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 610 - 614
1 May 2019
Aibinder WR Bartels DW Sperling JW Sanchez-Sotelo J

Aims

Shoulder arthroplasty using short humeral components is becoming increasingly popular. Some such components have been associated with relatively high rates of adverse radiological findings. The aim of this retrospective review was to evaluate the radiological humeral bone changes and mechanical failure rates with implantation of a short cementless humeral component in anatomical (TSA) and reverse shoulder arthroplasty (RSA).

Patients and Methods

A total of 100 shoulder arthroplasties (35 TSA and 65 RSA) were evaluated at a mean of 3.8 years (3 to 8.3). The mean age at the time of surgery was 68 years (31 to 90). The mean body mass index was 32.7 kg/m2 (17.3 to 66.4).


The Bone & Joint Journal
Vol. 101-B, Issue 1 | Pages 63 - 67
1 Jan 2019
Erickson BJ Ling D Wong A Eno JJ Dines JS Dines DM Gulotta LV

Aims

The number of rotator cuff repairs that are undertaken is increasing. Reverse shoulder arthroplasty (RSA) is the procedure of choice for patients with rotator cuff arthropathy. We sought to determine whether patients who underwent rotator cuff repair and subsequent RSA had different outcomes compared with a matched control group who underwent RSA without a previous rotator cuff repair.

Patients and Methods

All patients with a history of rotator cuff repair who underwent RSA between 2000 and 2015 with a minimum follow-up of two years were eligible for inclusion as the study group. Outcomes, including the American Shoulder and Elbow Surgeons (ASES) scores, were compared with a matched control group of patients who underwent RSA without having previously undergone rotator cuff repair.


The Bone & Joint Journal
Vol. 100-B, Issue 5 | Pages 603 - 609
1 May 2018
Schnetzke M Rick S Raiss P Walch G Loew M

Aims

The aim of this study was to evaluate the clinical and radiological outcome of using an anatomical short-stem shoulder prosthesis to treat primary osteoarthritis of the glenohumeral joint.

Patients and Methods

A total of 66 patients (67 shoulders) with a mean age of 76 years (63 to 92) were available for clinical and radiological follow-up at two different timepoints (T1, mean 2.6 years, sd 0.5; T2, mean 5.3 years, sd 0.7). Postoperative radiographs were analyzed for stem angle, cortical contact, and filling ratio of the stem. Follow-up radiographs were analyzed for timing and location of bone adaptation (cortical bone narrowing, osteopenia, spot welds, and condensation lines). The bone adaptation was classified as low (between zero and three features of bone remodelling around the humeral stem) or high (four or more features).


The Bone & Joint Journal
Vol. 100-B, Issue 8 | Pages 1066 - 1073
1 Aug 2018
Nishida K Hashizume K Nasu Y Ozawa M Fujiwara K Inoue H Ozaki T

Aims

The aim of this study was to report the mid-term clinical outcome of cemented unlinked J-alumina ceramic elbow (JACE) arthroplasties when used in patients with rheumatoid arthritis (RA).

Patients and Methods

We retrospectively reviewed 87 elbows, in 75 patients with RA, which was replaced using a cemented JACE total elbow arthroplasty (TEA) between August 2003 and December 2012, with a follow-up of 96%. There were 72 women and three men, with a mean age of 62 years (35 to 79). The mean follow-up was nine years (2 to 14). The clinical condition of each elbow before and after surgery was assessed using the Mayo Elbow Performance Index (MEPI, 0 to 100 points). Radiographic loosening was defined as a progressive radiolucent line of >1 mm that was completely circumferential around the prosthesis.


The Bone & Joint Journal
Vol. 100-B, Issue 3 | Pages 331 - 337
1 Mar 2018
Inui H Nobuhara K

Aims

We report the clinical results of glenoid osteotomy in patients with atraumatic posteroinferior instability associated with glenoid dysplasia.

Patients and Methods

The study reports results in 211 patients (249 shoulders) with atraumatic posteroinferior instability. The patients comprised 63 men and 148 women with a mean age of 20 years. The posteroinferior glenoid surface was elevated by osteotomy at the scapular neck. A body spica was applied to maintain the arm perpendicular to the glenoid for two weeks postoperatively. Clinical results were evaluated using the Rowe score and Japan Shoulder Society Shoulder Instability Score (JSS-SIS); bone union, osteoarthrosis, and articular congruity were examined on plain radiographs.


The Bone & Joint Journal
Vol. 100-B, Issue 4 | Pages 480 - 484
1 Apr 2018
Kadum B Inngul C Ihrman R Sjödén GO Sayed-Noor AS

Aims

The aims of this study were to investigate any possible relationship between a preoperative sensitivity to pain and the degree of pain at rest and on exertion with postoperative function in patients who underwent stemless total shoulder arthroplasty (TSA).

Patients and Methods

In this prospective study, we included 63 patients who underwent stemless TSA and were available for evaluation one year postoperatively. There were 31 women and 32 men; their mean age was 71 years (53 to 89). The pain threshold, which was measured using a Pain Matcher (PM) unit, the degree of pain (visual analogue scale at rest and on exertion, and function using the short version of the Disabilities of the Arm, Shoulder and Hand questionnaire (QuickDASH), were recorded preoperatively, as well as three and 12 months postoperatively.


The Bone & Joint Journal
Vol. 99-B, Issue 12 | Pages 1643 - 1650
1 Dec 2017
Chou W Wang C Wu K Yang Y Ko J Siu K

Aims

We conducted a study to identify factors that are prognostic of the outcome of extracorporeal shockwave therapy (ESWT) for calcific tendinitis of the shoulder.

Patients and Methods

Since 1998, patients with symptomatic calcific tendinitis of the rotator cuff have been treated with ESWT using an electrohydraulic mode shockwave device. One year after ESWT, patients were grouped according to the level of resorption of calcification.


The Bone & Joint Journal
Vol. 99-B, Issue 9 | Pages 1190 - 1196
1 Sep 2017
Swarup I Henn CM Nguyen JT Dines DM Craig EV Warren RF Gulotta LV Henn III RF

Aims

Few studies have evaluated the relationship between patients’ pre-operative expectations and the outcome of orthopaedic procedures. Our aim was to determine the effect of expectations on the outcome after primary anatomical total shoulder arthroplasty (TSA). We hypothesised that patients with greater expectations would have better outcomes.

Patients and Methods

Patients undergoing primary anatomical TSA completed the Hospital for Special Surgery’s Shoulder Expectations Survey pre-operatively. The American Shoulder and Elbow Surgeons (ASES), Shoulder Activity Scale (SAS), Short-Form-36 (SF-36), and visual analogue scale (VAS) for pain, fatigue, and general health scores were also collected pre-operatively and two years post-operatively. Pearson correlations were used to assess the relationship between the number of expectations and the outcomes. Differences in outcomes between those with higher and lower levels of expectations for each expectation were assessed by independent samples t-test. Multivariable linear regression analysis was used to control for potential confounding factors.


The Bone & Joint Journal
Vol. 99-B, Issue 8 | Pages 1073 - 1079
1 Aug 2017
Pauzenberger L Domej MA Heuberer PR Hexel M Grieb A Laky B Blasl J Anderl W

Aims

The purpose of the present study was to evaluate the impact of intravenous tranexamic acid on the reduction of blood loss, transfusion rate, and early post-operative clinical outcome in total shoulder arthroplasty.

Patients and Methods

A randomised, placebo-controlled trial which included 54 patients undergoing unilateral primary stemless anatomical or stemmed reverse total shoulder arthroplasty was undertaken. Patients received either 100 ml saline (placebo, n = 27), or 100 ml saline together with 1000 mg of tranexamic acid (TXA, n = 27) intravenously prior to skin incision and during wound closure. Peri-operative blood loss via an intra-articular drain was recorded and total blood loss was calculated. The post-operative transfusion rate was documented. Assessment of early clinical parameters included the visual analogue scale for pain (VAS), documentation of haematoma formation and adverse events.


The Bone & Joint Journal
Vol. 99-B, Issue 6 | Pages 818 - 823
1 Jun 2017
Kodama A Mizuseki T Adachi N

Aims

We assessed the long-term (more than ten-year) outcomes of the Kudo type-5 elbow prosthesis in patients with rheumatoid arthritis (RA).

Materials and Methods

We reviewed 41 elbows (Larsen Grade IV, n = 21; Grade V, n = 20) in 31 patients with RA who had undergone a Kudo type-5 total elbow arthroplasty (TEA) between 1994 and 2003, and had been followed up for more than ten years. The humeral component was cementless and the all-polyethylene ulnar component cemented in every patient. Clinical outcome was assessed using the Mayo elbow performance score. We calculated the revision rate and evaluated potential risk factors for revision. The duration of follow-up was a mean 141 months (120 to 203).


The Bone & Joint Journal
Vol. 99-B, Issue 6 | Pages 799 - 805
1 Jun 2017
Ketola S Lehtinen JT Arnala I

Aims

Rotator cuff tendinopathy has a multifactorial origin. Rejecting the mechanistic theory has also led to abandoning operative treatment at initial presentation in the first line. Physiotherapy exercise programmes are the accepted first line treatment. The aim of this study was to assess the long-term additional benefits of subacromial decompression in the treatment of rotator cuff tendinopathy.

Patients and Methods

This randomised controlled trial of 140 patients (52 men, 88 women, mean age 47.1 years; 18 to 60) with rotator cuff tendinopathy extended previous work up to a maximum of 13 years. The patients were randomised into two treatment groups: arthroscopic acromioplasty and a supervised exercise treatment and a similar supervised exercise treatment alone. Self-reported pain on a visual analogue scale (VAS) was the primary outcome measure. Secondary measures were disability, working ability, pain at night, Shoulder Disability Questionnaire score and the number of painful days during the three months preceding the final assessment.


The Bone & Joint Journal
Vol. 99-B, Issue 5 | Pages 674 - 679
1 May 2017
Nuttall D Birch A Haines JF Watts AC Trail IA

Aims

Radiostereometric analysis (RSA) allows an extremely accurate measurement of early micromotion of components following arthroplasty.

Patients and Methods

In this study, RSA was used to measure the migration of 11 partially cemented fluted pegged glenoid components in patients with osteoarthritis who underwent total shoulder arthroplasty using an improved surgical technique (seven men, four women, mean age 68). Patients were evaluated clinically using the American Shoulder and Elbow Surgeons (ASES) and Constant-Murley scores and by CT scans two years post-operatively.


The Bone & Joint Journal
Vol. 98-B, Issue 3 | Pages 374 - 380
1 Mar 2016
Kocsis G Thyagarajan DS Fairbairn KJ Wallace WA

Aims

Glenoid bone loss can be a challenging problem when revising a shoulder arthroplasty. Precise pre-operative planning based on plain radiographs or CT scans is essential. We have investigated a new radiological classification system to describe the degree of medialisation of the bony glenoid and that will indicate the amount of bone potentially available for supporting a glenoid component. It depends on the relationship between the most medial part of the articular surface of the glenoid with the base of the coracoid process and the spinoglenoid notch: it classifies the degree of bone loss into three types.

It also attempts to predict the type of glenoid reconstruction that may be possible (impaction bone grafting, structural grafting or simple non-augmented arthroplasty) and gives guidance about whether a pre-operative CT scan is indicated.

Patients and Methods

Inter-method reliability between plain radiographs and CT scans was assessed retrospectively by three independent observers using data from 39 randomly selected patients.

Inter-observer reliability and test-retest reliability was tested on the same cohort using Cohen's kappa statistics. Correlation of the type of glenoid with the Constant score and its pain component was analysed using the Kruskal-Wallis method on data from 128 patients. Anatomical studies of the scapula were reviewed to explain the findings.


The Bone & Joint Journal
Vol. 98-B, Issue 9 | Pages 1215 - 1221
1 Sep 2016
Verhofste B Decock T Van Tongel A De Wilde L

Aims

Heterotopic ossification (HO) occurs after arthroplasty, especially total hip arthroplasty. In this study we describe the incidence, evolution, morphology and clinical consequences of HO following reverse shoulder arthroplasty.

Patients and Methods

This is a single-centre retrospective study of 132 consecutive patients who received a Delta III or Delta Xtend reverse total shoulder arthroplasty between 2006 and 2013 for the treatment of cuff tear arthropathy. There were 96 women and 36 men. Their mean age at the time of surgery was 69 years (49 to 89) and the mean follow-up was 36 months (12 to 84). The incidence, evolution, morphology and clinical consequences of HO using the Constant-Murley score (CS) were analysed. A modified Brooker classification of HO of the hip was used.


The Bone & Joint Journal
Vol. 98-B, Issue 2 | Pages 209 - 217
1 Feb 2016
Satbhai NG Doi K Hattori Y Sakamoto S

Aims

Between 2002 and 2011, 81 patients with a traumatic total brachial plexus injury underwent reconstruction by double free muscle transfer (DFMT, 47 cases), single muscle transfer (SMT, 16 cases) or nerve transfers (NT, 18 cases).

Methods

They were evaluated for functional outcome and quality of life (QoL) using the Disability of Arm, Shoulder and Hand questionnaire, both pre- and post-operatively. The three groups were compared and followed-up for at least 24 months.


The Bone & Joint Journal
Vol. 98-B, Issue 3 | Pages 381 - 386
1 Mar 2016
Prasad N Ali A Stanley D

Aims

We review our experience of Coonrad-Morrey total elbow arthroplasty (TEA) for fractures of the distal humerus in non-rheumatoid patients with a minimum of ten years follow-up.

Patients and Methods

TEA through a triceps splitting approach was peformed in 37 non-rheumatoid patients for a fracture of the distal humerus between 1996 and 2004. One patient could not be traced and 17 had died before the tenth anniversary of their surgery. This left 19 patients with a minimum follow-up of ten years to form the study group. Of these, 13 patients were alive at the time of final review. The other six had died, but after the tenth anniversary of their elbow arthroplasty. Their clinical and radiological data were included in the study.


The Bone & Joint Journal
Vol. 97-B, Issue 5 | Pages 681 - 688
1 May 2015
Wagener ML de Vos MJ Hannink G van der Pluijm M Verdonschot N Eygendaal D

Unlinked, linked and convertible total elbow arthroplasties (TEAs) are currently available. This study is the first to report the clinical results of the convertible Latitude TEA. This was a retrospective study of a consecutive cohort of 63 patients (69 primary TEAs) with a mean age of 60 years (23 to 87). Between 2006 and 2008 a total of 19 men and 50 women underwent surgery. The mean follow-up was 43 months (8 to 84). The range of movement, function and pain all improved six months post-operatively and either continued to improve slightly or reached a plateau thereafter. The complication rate is similar to that reported for other TEA systems. No loosening was seen. Remarkable is the disengagement of the radial head component in 13 TEAs (31%) with a radial head component implanted.

Implantation of both the linked and the unlinked versions of the Latitude TEA results in improvement of function and decreased pain, and shows high patient satisfaction at mid-term follow-up.

Cite this article: Bone Joint J 2015; 97-B:681–8.


The Bone & Joint Journal
Vol. 96-B, Issue 9 | Pages 1239 - 1243
1 Sep 2014
Zafra M Uceda P Flores M Carpintero P

Patients with pain and loss of shoulder function due to nonunion of a fracture of the proximal third of the humerus may benefit from reverse total shoulder replacement. This paper reports a prospective, multicentre study, involving three hospitals and three surgeons, of 35 patients (28 women, seven men) with a mean age of 69 years (46 to 83) who underwent a reverse total shoulder replacement for the treatment of nonunion of a fracture of the proximal humerus. Using Checchia’s classification, nine nonunions were type I, eight as type II, 12 as type III and six as type IV. The mean follow-up was 51 months (24 to 99). Post-operatively, the patients had a significant decrease in pain (p < 0.001), and a significant improvement in flexion, abduction, external rotation and Constant score (p < 0.001), but not in internal rotation. A total of nine complications were recorded in seven patients: six dislocations, one glenoid loosening in a patient who had previously suffered dislocation, one transitory paresis of the axillary nerve and one infection.

Reverse total shoulder replacement may lead to a significant reduction in pain, improvement in function and a high degree of satisfaction. However, the rate of complications, particularly dislocation, was high.

Cite this article: Bone Joint J 2014;96-B:1239–43.


The Bone & Joint Journal
Vol. 96-B, Issue 7 | Pages 936 - 942
1 Jul 2014
Middleton C Uri O Phillips S Barmpagiannis K Higgs D Falworth M Bayley I Lambert S

Inherent disadvantages of reverse shoulder arthroplasty designs based on the Grammont concept have raised a renewed interest in less-medialised designs and techniques. The aim of this study was to evaluate the outcome of reverse shoulder arthroplasty (RSA) with the fully-constrained, less-medialised, Bayley–Walker prosthesis performed for the treatment of rotator-cuff-deficient shoulders with glenohumeral arthritis. A total of 97 arthroplasties in 92 patients (53 women and 44 men, mean age 67 years (standard deviation (sd) 10, (49 to 85)) were retrospectively reviewed at a mean follow-up of 50 months ((sd 25) (24 to 96)). The mean Oxford shoulder score and subjective shoulder value improved from 47 (sd 9) and 24 points (sd 18) respectively before surgery to 28 (sd 11) and 61 (sd 24) points after surgery (p <  0.001). The mean pain at rest decreased from 5.3 (sd 2.8) to 1.5 (sd 2.3) (p < 0.001). The mean active forward elevation and external rotation increased from 42°(sd 30) and 9° (sd 15) respectively pre-operatively to 78° (sd 39) and 24° (sd 17) post-operatively (p < 0.001). A total of 20 patients required further surgery for complications; 13 required revision of components. No patient developed scapular notching.

The Bayley–Walker prosthesis provides reliable pain relief and reasonable functional improvement for patients with symptomatic cuff-deficient shoulders. Compared with other designs of RSA, it offers a modest improvement in forward elevation, but restores external rotation to some extent and prevents scapular notching. A longer follow-up is required to assess the survival of the prosthesis and the clinical performance over time.

Cite this article: Bone Joint J 2014;96-B:936–42.


The Bone & Joint Journal
Vol. 96-B, Issue 4 | Pages 526 - 529
1 Apr 2014
Giuseffi SA Streubel P Sperling J Sanchez-Sotelo J

Short uncemented humeral stems can preserve humeral bone stock and facilitate revision surgery but may be prone to malalignment or loosening, especially when used in reverse total shoulder replacement (TSR). We undertook a retrospective review of 44 patients with a mean age of 76 years (59 to 92) who underwent primary reverse TSR with a short uncemented humeral stem. There were 29 females. The indications for joint replacement included cuff tear associated arthropathy (33), avascular necrosis (six), post-traumatic arthritis (two), and inflammatory arthritis (three). At a mean follow-up of 27 months (24 to 40), pain was rated as mild or none in 43 shoulders (97.7%). The mean active elevation improved from 54° (sd 20°) to 142° (sd 25°) and the mean active external rotation from 14° (sd 13°) to 45° (sd 9°). The outcome, as assessed by the modified Neer score, was excellent in 27 (61.3%), satisfactory in 15 (34.1%), and unsatisfactory in two shoulders (4.5%). Stems were well-positioned, without evidence of significant valgus or varus malalignment in 42 TSRs (95.5%). There was no radiological evidence of loosening of the humeral stem in any patient; 13 TSRs (29.5%) had evidence of proximal humeral remodelling and scapular notching was noted in three (6.8%).

Cite this article: Bone Joint J 2014;96-B:526–9.


The Bone & Joint Journal
Vol. 96-B, Issue 2 | Pages 237 - 241
1 Feb 2014
Miyake J Shimada K Oka K Tanaka H Sugamoto K Yoshikawa H Murase T

We retrospectively assessed the value of identifying impinging osteophytes using dynamic computer simulation of CT scans of the elbow in assisting their arthroscopic removal in patients with osteoarthritis of the elbow. A total of 20 patients were treated (19 men and one woman, mean age 38 years (19 to 55)) and followed for a mean of 25 months (24 to 29). We located the impinging osteophytes dynamically using computerised three-dimensional models of the elbow based on CT data in three positions of flexion of the elbow. These were then removed arthroscopically and a capsular release was performed.

The mean loss of extension improved from 23° (10° to 45°) pre-operatively to 9° (0° to 25°) post-operatively, and the mean flexion improved from 121° (80° to 140°) pre-operatively to 130° (110° to 145°) post-operatively. The mean Mayo Elbow Performance Score improved from 62 (30 to 85) to 95 (70 to 100) post-operatively. All patients had pain in the elbow pre-operatively which disappeared or decreased post-operatively. According to their Mayo scores, 14 patients had an excellent clinical outcome and six a good outcome; 15 were very satisfied and five were satisfied with their post-operative outcome.

We recommend this technique in the surgical management of patients with osteoarthritis of the elbow.

Cite this article: Bone Joint J 2014;96-B:237–41.


The Bone & Joint Journal
Vol. 96-B, Issue 2 | Pages 224 - 228
1 Feb 2014
Simone JP Streubel PH Athwal GS Sperling JW Schleck CD Cofield RH

We assessed the clinical results, radiographic outcomes and complications of patients undergoing total shoulder replacement (TSR) for osteoarthritis with concurrent repair of a full-thickness rotator cuff tear. Between 1996 and 2010, 45 of 932 patients (4.8%) undergoing TSR for osteoarthritis underwent rotator cuff repair. The final study group comprised 33 patients with a mean follow-up of 4.7 years (3 months to 13 years). Tears were classified into small (10), medium (14), large (9) or massive (0). On a scale of 1 to 5, pain decreased from a mean of 4.7 to 1.7 (p = < 0.0001), the mean forward elevation improved from 99° to 139° (p = < 0.0001), and the mean external rotation improved from 20° (0° to 75°) to 49° (20° to 80°) (p = < 0.0001). The improvement in elevation was greater in those with a small tear (p = 0.03). Radiographic evidence of instability developed in six patients with medium or large tears, indicating lack of rotator cuff healing. In all, six glenoid components, including one with instability, were radiologically at risk of loosening. Complications were noted in five patients, all with medium or large tears; four of these had symptomatic instability and one sustained a late peri-prosthetic fracture. Four patients (12%) required further surgery, three with instability and one with a peri-prosthetic humeral fracture.

Consideration should be given to performing rotator cuff repair for stable shoulders during anatomical TSR, but reverse replacement should be considered for older, less active patients with larger tears.

Cite this article: Bone Joint J 2014;96-B:224–8.


The Bone & Joint Journal
Vol. 95-B, Issue 11 | Pages 1521 - 1526
1 Nov 2013
Kolk A Auw Yang KG Tamminga R van der Hoeven H

The aim of this study was to determine the effect of radial extracorporeal shock-wave therapy (rESWT) on patients with chronic tendinitis of the rotator cuff. This was a randomised controlled trial in which 82 patients (mean age 47 years (24 to 67)) with chronic tendinitis diagnosed clinically were randomly allocated to a treatment group who received low-dose rESWT (three sessions at an interval 10 to 14 days, 2000 pulses, 0.11 mJ/mm. 2. , 8 Hz) or to a placebo group, with a follow-up of six months. The patients and the treating orthopaedic surgeon, who were both blinded to the treatment, evaluated the results. A total of 44 patients were allocated to the rESWT group and 38 patients to the placebo group. A visual analogue scale (VAS) score for pain, a Constant–Murley (CMS) score and a simple shoulder test (SST) score significantly improved in both groups at three and six months compared with baseline (all p ≤ 0.012). The mean VAS was similar in both groups at three (p = 0.43) and six months (p = 0.262). Also, the mean CMS and SST scores were similar in both groups at six months (p = 0.815 and p = 0.834, respectively). It would thus seem that low-dose rESWT does not reduce pain or improve function in patients chronic rotator cuff tendinitis compared with placebo treatment. Cite this article: Bone Joint J 2013;95-B:1521–6


The Bone & Joint Journal
Vol. 95-B, Issue 9 | Pages 1232 - 1238
1 Sep 2013
Wiater BP Boone CR Koueiter DM Wiater JM

Some surgeons are reluctant to perform a reverse total shoulder arthroplasty (RTSA) on both shoulders because of concerns regarding difficulty with activities of daily living post-operatively as a result of limited rotation of the shoulders. Nevertheless, we hypothesised that outcomes and patient satisfaction following bilateral RTSA would be comparable to those following unilateral RTSA. A single-surgeon RTSA registry was reviewed for patients who underwent bilateral staged RTSA with a minimum follow-up of two years. A unilateral RTSA matched control was selected for each shoulder in those patients undergoing bilateral procedures. The Constant–Murley score (CMS), American Shoulder and Elbow Surgeons (ASES) score, Subjective Shoulder Values (SSV), visual analogue scale (VAS) for pain, range of movement and strength were measured pre- and post-operatively. The mean CMS, ASES, SSV, VAS scores, strength and active forward elevation were significantly improved (all p < 0.01) following each operation in those undergoing bilateral procedures. The mean active external rotation (p = 0.63 and p = 0.19) and internal rotation (p = 0.77 and p = 0.24) were not significantly improved. The improvement in the mean ASES score after the first RTSA was greater than the improvement in its control group (p = 0.0039). The improvement in the mean CMS, ASES scores and active forward elevation was significantly less after the second RTSA than in its control group (p = 0.0244, p = 0.0183, and p = 0.0280, respectively). Pain relief and function significantly improved after each RTSA in those undergoing a bilateral procedure.

Bilateral RTSA is thus a reasonable form of treatment for patients with severe bilateral rotator cuff deficiency, although inferior results may be seen after the second procedure compared with the first.

Cite this article: Bone Joint J 2013;95-B:1232–8.