Advertisement for orthosearch.org.uk
Results 1 - 5 of 5
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 1 | Pages 108 - 112
1 Jan 2009
Chandrasekar CR Grimer RJ Carter SR Tillman RM Abudu A Buckley L

Endoprosthetic replacement of the proximal femur may be required to treat primary bone tumours or destructive metastases either with impending or established pathological fracture. Modular prostheses are available off the shelf and can be adapted to most reconstructive situations for this purpose. We have assessed the clinical and functional outcome of using the METS (Stanmore Implants Worldwide) modular tumour prosthesis to reconstruct the proximal femur in 100 consecutive patients between 2001 and 2006. We compared the results with the published series for patients managed with modular and custom-made endoprosthetic replacements for the same conditions. There were 52 males and 48 females with a mean age of 56.3 years (16 to 84) and a mean follow-up of 24.6 months (0 to 60). In 65 patients the procedure was undertaken for metastases, in 25 for a primary bone tumour, and in ten for other malignant conditions. A total of 46 patients presented with a pathological fracture, and 19 presented with failed fixation of a previous pathological fracture. The overall patient survival was 63.6% at one year and 23.1% at five years, and was significantly better for patients with a primary bone tumour than for those with metastatic tumour (82.3% vs 53.3%, respectively at one year (p = 0.003)). There were six early dislocations of which five could be treated by closed reduction. No patient needed revision surgery for dislocation. Revision surgery was required by six (6%) patients, five for pain caused by acetabular wear and one for tumour progression. Amputation was needed in four patients for local recurrence or infection. The estimated five-year implant survival with revision as the endpoint was 90.7%. The mean Toronto Extremity Salvage score was 61% (51% to 95%). The implant survival and complications resulting from the use of the modular system were comparable to the published series of both custom-made and other modular proximal femoral implants. We conclude that at intermediate follow-up the modular tumour prosthesis for proximal femur replacement provides versatility, a low incidence of implant-related complications and acceptable function for patients with metastatic tumours, pathological fractures and failed fixation of the proximal femur. It also functions as well as a custom-made endoprosthetic replacement


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 3 | Pages 400 - 403
1 May 1996
Voggenreiter G Assenmacher S Klaes W Schmit-Neuerburg K

We have used total hip replacement combined with cemented intramedullary nailing to treat a selected group of nine patients with pathological fractures of the proximal femur and impending fractures of the shaft due to metastases. One patient died from cardiopulmonary failure on the third postoperative day, but the others were able to walk within the first week after operation. Complications included one recurrent dislocation of the THR and one fracture of an osteolytic lesion of the femoral shaft during nail insertion. Both were managed successfully. The hybrid osteosynthesis which we describe is an alternative to the use of tumour or long-stem prostheses; it has the advantage of preserving bone stock and muscle attachments


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1285 - 1291
1 Oct 2019
MacKenzie SA Ng RT Snowden G Powell-Bowns MFR Duckworth AD Scott CEH

Aims

Currently, periprosthetic fractures are excluded from the American Society for Bone and Mineral Research (ASBMR) definition of atypical femoral fracture (AFFs). This study aims to report on a series of periprosthetic femoral fractures (PFFs) that otherwise meet the criteria for AFFs. Secondary aims were to identify predictors of periprosthetic atypical femoral fractures (PAFFs) and quantify the complications of treatment.

Patients and Methods

This was a retrospective case control study of consecutive patients with periprosthetic femoral fractures between 2007 and 2017. Two observers identified 16 PAFF cases (mean age 73.9 years (44 to 88), 14 female patients) and 17 typical periprosthetic fractures in patients on bisphosphonate therapy as controls (mean age 80.7 years (60 to 86, 13 female patients). Univariate and multivariate analysis was performed to identify predictors of PAFF. Management and complications were recorded.


The Bone & Joint Journal
Vol. 95-B, Issue 9 | Pages 1269 - 1274
1 Sep 2013
Uppal HS Peterson BE Misfeldt ML Della Rocca GJ Volgas DA Murtha YM Stannard JP Choma TJ Crist BD

We hypothesised that cells obtained via a Reamer–Irrigator–Aspirator (RIA) system retain substantial osteogenic potential and are at least equivalent to graft harvested from the iliac crest. Graft was harvested using the RIA in 25 patients (mean age 37.6 years (18 to 68)) and from the iliac crest in 21 patients (mean age 44.6 years (24 to 78)), after which ≥ 1 g of bony particulate graft material was processed from each. Initial cell viability was assessed using Trypan blue exclusion, and initial fluorescence-activated cell sorting (FACS) analysis for cell lineage was performed. After culturing the cells, repeat FACS analysis for cell lineage was performed and enzyme-linked immunosorbent assay (ELISA) for osteocalcin, and Alizarin red staining to determine osteogenic potential. Cells obtained via RIA or from the iliac crest were viable and matured into mesenchymal stem cells, as shown by staining for the specific mesenchymal antigens CD90 and CD105. For samples from both RIA and the iliac crest there was a statistically significant increase in bone production (both p < 0.001), as demonstrated by osteocalcin production after induction.

Medullary autograft cells harvested using RIA are viable and osteogenic. Cell viability and osteogenic potential were similar between bone grafts obtained from both the RIA system and the iliac crest.

Cite this article: Bone Joint J 2013;95-B:1269–74.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 8 | Pages 1064 - 1068
1 Aug 2009
Sankey RA Turner J Lee J Healy J Gibbons CER

An MR scan was performed on all patients who presented to our hospital with a clinical diagnosis of a fracture of the proximal femur, but who had no abnormality on plain radiographs. This was a prospective study of 102 consecutive patients over a ten-year period. There were 98 patients who fulfilled our inclusion criteria, of whom 75 were scanned within 48 hours of admission, with an overall mean time between admission and scanning of 2.4 days (0 to 10). A total of 81 patients (83%) had abnormalities detected on MRI; 23 (23%) required operative management.

The use of MRI led to the early diagnosis and treatment of occult hip pathology. We recommend that incomplete intertrochanteric fractures are managed non-operatively with protected weight-bearing. The study illustrates the high incidence of fractures which are not apparent on plain radiographs, and shows that MRI is useful when diagnosing other pathology such as malignancy, which may not be apparent on plain films.