Aims. Prosthetic joint infection (PJI) remains a major clinical challenge. Neutrophil CD64 index, Fc-gamma receptor 1 (FcγR1), plays an important role in mediating inflammation of bacterial infections and therefore could be a valuable biomarker for PJI. The aim of this study is to compare the neutrophil CD64 index in synovial and blood diagnostic ability with the standard
The surgical helmet system (SHS) was developed to reduce the risk of periprosthetic joint infection (PJI), but the evidence is contradictory, with some studies suggesting an increased risk of PJI due to potential leakage through the glove-gown interface (GGI) caused by its positive pressure. We assumed that SHS and glove exchange had an impact on the leakage via GGI. There were 404 arthroplasty simulations with fluorescent gel, in which SHS was used (H+) or not (H-), and GGI was sealed (S+) or not (S-), divided into four groups: H+S+, H+S-, H-S+, and H-S-, varying by exposure duration (15 to 60 minutes) and frequency of glove exchanges (0 to 6 times). The intensity of fluorescent leakage through GGI was quantified automatically with an image analysis software. The effect of the above factors on fluorescent leakage via GGI were compared and analyzed.Aims
Methods
To review the evidence and reach consensus on recommendations for follow-up after total hip and knee arthroplasty. A programme of work was conducted, including: a systematic review of the clinical and cost-effectiveness literature; analysis of routine national datasets to identify pre-, peri-, and postoperative predictors of mid-to-late term revision; prospective data analyses from 560 patients to understand how patients present for revision surgery; qualitative interviews with NHS managers and orthopaedic surgeons; and health economic modelling. Finally, a consensus meeting considered all the work and agreed the final recommendations and research areas.Aims
Methods
The aims of this study were to: 1) report on a cohort of skeletally mature patients with native hip and knee septic arthritis over a 14-year period; 2) to determine the rate of joint failure in patients who had experienced an episode of hip or knee septic arthritis; and 3) to assess the outcome following septic arthritis relative to the infecting organism, whether those patients infected by All microbiological samples from joint aspirations between March 2000 and December 2014 at our institution were reviewed in order to identify cases of culture-proven septic arthritis. Cases in children (aged < 16 years) and prosthetic joints were excluded. Data were abstracted on age at diagnosis, sex, joint affected (hip or knee), type of organisms isolated, cause of septic arthritis, comorbidities within the Charlson Comorbidity Index (CCI), details of treatment, and outcome.Aims
Methods
Gram-negative periprosthetic joint infection (PJI) has been poorly studied despite its rapidly increasing incidence. Treatment with one-stage revision using intra-articular (IA) infusion of antibiotics may offer a reasonable alternative with a distinct advantage of providing a means of delivering the drug in high concentrations. Carbapenems are regarded as the last line of defense against severe Gram-negative or polymicrobial infection. This study presents the results of one-stage revision using intra-articular carbapenem infusion for treating Gram-negative PJI, and analyzes the characteristics of bacteria distribution and drug sensitivity. We retrospectively reviewed 32 patients (22 hips and 11 knees) who underwent single-stage revision combined with IA carbapenem infusion between November 2013 and March 2020. The IA and intravenous (IV) carbapenem infusions were administered for a single Gram-negative infection, and IV vancomycin combined with IA carbapenems and vancomycin was applied for polymicrobial infection including Gram-negative bacteria. The bacterial community distribution, drug sensitivity, infection control rate, functional recovery, and complications were evaluated. Reinfection or death caused by PJI was regarded as a treatment failure.Aims
Methods
The purpose of this study was to determine the association between prior sleeve gastrectomy in patients undergoing primary total hip and knee arthroplasty, and 90-day complications, incidence of revision arthroplasty, and patient-reported outcome scores at final follow-up. This is a retrospective, single-centre analysis. Patients undergoing primary hip or knee arthroplasty with a prior sleeve gastrectomy were eligible for inclusion (n = 80 patients). A morbidly obese control group was established from the same institutional registry using a 1:2 match, for cases:controls with arthroplasty based on propensity score using age, sex, pre-sleeve gastrectomy BMI, Current Procedural Terminology code to identify anatomical location, and presurgical haemoglobin A1C. Outcomes included 90-day complications, incidence of revision arthroplasty, and patient-reported outcome scores at final follow-up. Multivariable logistic regressions evaluated associations of underlying preoperative demographic and treatment characteristics with outcomes.Aims
Methods
Tranexamic acid (TXA) is now commonly used in major surgical operations including orthopaedics. The TRAC-24 randomized control trial (RCT) aimed to assess if an additional 24 hours of TXA postoperatively in primary total hip (THA) and total knee arthroplasty (TKA) reduced blood loss. Contrary to other orthopaedic studies to date, this trial included high-risk patients. This paper presents the results of a cost analysis undertaken alongside this RCT. TRAC-24 was a prospective RCT on patients undergoing TKA and THA. Three groups were included: Group 1 received 1 g intravenous (IV) TXA perioperatively and an additional 24-hour postoperative oral regime, Group 2 received only the perioperative dose, and Group 3 did not receive TXA. Cost analysis was performed out to day 90.Aims
Methods
Aims. α-defensin is a biomarker which has been described as having
a high degree of accuracy in the diagnosis of periprosthetic joint
infection (PJI). Current meta-analyses are based on the α-defensin
laboratory-based immunoassay rather than the quick on-table lateral
flow test kit. This study is the first meta-analysis to compare the
accuracy of the α-defensin laboratory-based immunoassay and the
lateral flow test kit for the diagnosis of PJI. Materials and Methods. A systematic review was performed according to the Preferred
Reporting Items for Systematic Reviews and Meta-Analyses guidelines.
Inclusion criteria were all
Antibiotic prophylaxis involving timely administration of appropriately dosed antibiotic is considered effective to reduce the risk of surgical site infection (SSI) after total hip and total knee arthroplasty (THA/TKA). Cephalosporins provide effective prophylaxis, although evidence regarding the optimal timing and dosage of prophylactic antibiotics is inconclusive. The aim of this study is to examine the association between cephalosporin prophylaxis dose, timing, and duration, and the risk of SSI after THA/TKA. A prospective multicentre cohort study was undertaken in consenting adults with osteoarthritis undergoing elective primary TKA/THA at one of 19 high-volume Australian public/private hospitals. Data were collected prior to and for one-year post surgery. Logistic regression was undertaken to explore associations between dose, timing, and duration of cephalosporin prophylaxis and SSI. Data were analyzed for 1,838 participants. There were 264 SSI comprising 63 deep SSI (defined as requiring intravenous antibiotics, readmission, or reoperation) and 161 superficial SSI (defined as requiring oral antibiotics) experienced by 249 (13.6%) participants within 365 days of surgery.Aims
Methods
Objectives. To assess the responsiveness and ceiling/floor effects of the Forgotten Joint Score -12 and to compare these with that of the more widely used Oxford Hip Score (OHS) in patients six and 12 months after primary total hip arthroplasty. Methods. We prospectively collected data at six and 12 months following total hip arthroplasty from 193 patients undergoing surgery at a single centre. Ceiling effects are outlined with frequencies for patients obtaining the lowest or highest possible score. Change over time from six months to 12 months post-surgery is reported as effect size (Cohen’s d). Results. The mean OHS improved from 40.3 (. sd. 7.9) at six months to 41.9 (. sd. 7.2) at 12 months. The mean FJS-12 improved from 56.8 (. sd. 30.1) at six months to 62.1 (. sd. 29.0) at 12 months. At six months, 15.5% of patients reached the best possible score (48 points) on the OHS and 8.3% obtained the best score (100 points) on the FJS-12. At 12 months, this percentage increased to 20.8% for the OHS and to 10.4% for the FJS-12. In terms of the effect size (Cohen’s d), the change was d = 0.10 for the OHS and d = 0.17 for the FJS-12. Conclusions. The FJS-12 is more responsive to change between six and 12 months following total hip arthroplasty than is the OHS, with the measured ceiling effect for the OHS twice that of the FJS-12. The difference in effect size of change results in substantial differences in required sample size if aiming to detect change between these two time points. This has important implications for powering
The aim of this study was to determine the diagnostic accuracy of α defensin (AD) lateral flow assay (LFA) and enzyme-linked immunosorbent assay (ELISA) tests for periprosthetic joint infection (PJI) in comparison to conventional synovial white blood cell (WBC) count and polymorphonuclear neutrophil percentage (PMN%) analysis. Patients undergoing joint aspiration for evaluation of pain after total knee arthroplasty (TKA) or total hip arthroplasty (THA) were considered for inclusion. Synovial fluids from 99 patients (25 THA and 74 TKA) were analyzed by WBC count and PMN% analysis, AD LFA, and AD ELISA. WBC and PMN% cutoffs of ≥ 1,700 cells/mm3 and ≥ 65% for TKA and ≥ 3,000 cells/mm3 and ≥ 80% for THA were used, respectively. A panel of three physicians, all with expertise in orthopaedic infections and who were blinded to the results of AD tests, independently reviewed patient data to diagnose subjects as with or without PJI. Consensus PJI classification was used as the reference standard to evaluate test performances. Results were compared using McNemar’s test and area under the receiver operating characteristic curve (AUC) analysis.Aims
Methods
The aim of this study was to develop a single-layer hybrid organic-inorganic sol-gel coating that is capable of a controlled antibiotic release for cementless hydroxyapatite (HA)-coated titanium orthopaedic prostheses. Coatings containing gentamicin at a concentration of 1.25% weight/volume (wt/vol), similar to that found in commercially available antibiotic-loaded bone cement, were prepared and tested in the laboratory for: kinetics of antibiotic release; activity against planktonic and biofilm bacterial cultures; biocompatibility with cultured mammalian cells; and physical bonding to the material (n = 3 in all tests). The sol-gel coatings and controls were then tested in vivo in a small animal healing model (four materials tested; n = 6 per material), and applied to the surface of commercially pure HA-coated titanium rods.Aims
Methods
Periprosthetic joint infections (PJIs) are among the most devastating complications after joint arthroplasty. There is limited evidence on the efficacy of different antiseptic solutions on reducing biofilm burden. The purpose of the present study was to test the efficacy of different antiseptic solutions against clinically relevant microorganisms in biofilm. We conducted an in vitro study examining the efficacy of several antiseptic solutions against clinically relevant microorganisms. We tested antiseptic irrigants against nascent (four-hour) and mature (three-day) single-species biofilm created in vitro using a drip-flow reactor model.Aims
Methods
As a proven and comprehensive molecular technique, metagenomic next-generation sequencing (mNGS) has shown its potential in the diagnosis of pathogens in patients with periprosthetic joint infection (PJI), using a single type of specimen. However, the optimal use of mNGS in the management of PJI has not been explored. In this study, we evaluated the diagnostic value of mNGS using three types of specimen with the aim of achieving a better choice of specimen for mNGS in these patients. In this prospective study, 177 specimens were collected from 59 revision arthroplasties, including periprosthetic tissues, synovial fluid, and prosthetic sonicate fluid. Each specimen was divided into two, one for mNGS and one for culture. The criteria of the Musculoskeletal Infection Society were used to define PJI (40 cases) and aseptic failure (19 cases).Aims
Methods
Post-operative complications after total hip
or knee replacement can delay recovery, prolong hospitalisation, increase
rates of re-admission and, in the most severe cases, lead to long-term
disability or even death. In this analysis of pooled data from four
large, randomised, phase III
Rivaroxaban has been recommended for routine use as a thromboprophylactic agent in patients undergoing lower-limb arthroplasty. However, trials supporting its use have not fully evaluated the risks of wound complications. This study of 1048 total hip/knee replacements records the rates of return to theatre and infection before and after the change from a low molecular weight heparin (tinzaparin) to rivaroxaban as the agent of chemical thromboprophylaxis in patients undergoing lower-limb arthroplasty. During a period of 13 months, 489 consecutive patients undergoing lower-limb arthroplasty received tinzaparin and the next 559 consecutive patients received rivaroxaban as thromboprophylaxis. Nine patients in the control (tinzaparin) group (1.8%, 95% confidence interval 0.9 to 3.5) returned to theatre with wound complications within 30 days, compared with 22 patients in the rivaroxaban group (3.94%, 95% confidence interval 2.6 to 5.9). This increase was statistically significant (p = 0.046). The proportion of patients who returned to theatre and became infected remained similar (p = 0.10). Our study demonstrates the need for further randomised controlled
A new generation of knee prostheses has been introduced with the intention of improving post-operative knee flexion. In order to evaluate whether this goal has been achieved we performed a systematic review and meta-analysis. Systematic literature searches were conducted on MEDLINE and EMBASE from their inception to December 2007, and proceedings of scientific meetings were also searched. Only randomised,
Removal of infected components and culture-directed antibiotics are important for the successful treatment of chronic periprosthetic joint infection (PJI). However, as many as 27% of chronic PJI patients yield negative culture results. Although culture negativity has been thought of as a contraindication to one-stage revision, data supporting this assertion are limited. The aim of our study was to report on the clinical outcomes for one-stage and two-stage exchange arthroplasty performed in patients with chronic culture-negative PJI. A total of 105 consecutive patients who underwent revision arthroplasty for chronic culture-negative PJI were retrospectively evaluated. One-stage revision arthroplasty was performed in 30 patients, while 75 patients underwent two-stage exchange, with a minimum of one year's follow-up. Reinfection, re-revision for septic and aseptic reasons, amputation, readmission, mortality, and length of stay were compared between the two treatment strategies.Aims
Methods
The diagnosis of periprosthetic joint infection (PJI) can be difficult. All current diagnostic tests have problems with accuracy and interpretation of results. Many new tests have been proposed, but there is no consensus on the place of many of these in the diagnostic pathway. Previous attempts to develop a definition of PJI have not been universally accepted and there remains no reference standard definition. This paper reports the outcome of a project developed by the European Bone and Joint Infection Society (EBJIS), and supported by the Musculoskeletal Infection Society (MSIS) and the European Society of Clinical Microbiology and Infectious Diseases (ESCMID) Study Group for Implant-Associated Infections (ESGIAI). It comprised a comprehensive review of the literature, open discussion with Society members and conference delegates, and an expert panel assessment of the results to produce the final guidance.Aims
Methods
This prospective randomised
Arthrofibrosis is a relatively common complication after joint injuries and surgery, particularly in the knee. The present study used a previously described and validated rabbit model to assess the biomechanical, histopathological, and molecular effects of the mast cell stabilizer ketotifen on surgically induced knee joint contractures in female rabbits. A group of 12 skeletally mature rabbits were randomly divided into two groups. One group received subcutaneous (SQ) saline, and a second group received SQ ketotifen injections. Biomechanical data were collected at eight, ten, 16, and 24 weeks. At the time of necropsy, posterior capsule tissue was collected for histopathological and gene expression analyses (messenger RNA (mRNA) and protein).Aims
Methods
We performed a meta-analysis to evaluate the relative efficacy of regional and general anaesthesia in patients undergoing total hip or knee replacement. A comprehensive search for relevant studies was performed in PubMed (1966 to April 2008), EMBASE (1969 to April 2008) and the Cochrane Library. Only randomised studies comparing regional and general anaesthesia for total hip or knee replacement were included. We identified 21 independent, randomised
We made a
The aim of this study was to conduct the largest low contact stress (LCS) retrieval study to elucidate the failure mechanisms of the Porocoat and Duofix femoral component. The latter design was voluntarily recalled by the manufacturer. Uncemented LCS explants were divided into three groups: Duofix, Porocoat, and mixed. Demographics, polyethylene wear, tissue ingrowth, and metallurgical analyses were performed.Aims
Materials and Methods
Aims
Patients and Methods
The aim of this study was to assess the effect of multimorbidity
on improvements in health-related quality of life (HRQoL) following
total hip arthroplasty (THA) and total knee arthroplasty (TKA). Using data from a regional joint registry for 14 573 patients,
HRQoL was measured prior and one year following surgery using the
Oxford Hip Score (OHS) and Oxford Knee Score (OKS), and the 12-Item
Short-Form Health Survey Physical and Mental Component Summary scores
(PCS and MCS, respectively). Multimorbidity was defined as the concurrence
of two or more self-reported chronic conditions. A linear mixed-effects
model was used to test the effects of multimorbidity and the number
of chronic conditions on improvements in HRQoL.Aims
Patients and Methods
Surgical site infection (SSI) is a common complication of surgery
with an incidence of about 1% in the United Kingdom. Sutures can
lead to the development of a SSI, as micro-organisms can colonize
the suture as it is implanted. Triclosan-coated sutures, being antimicrobical,
were developed to reduce the rate of SSI. Our aim was to assess
whether triclosan-coated sutures cause a reduction in SSIs following
arthroplasty of the hip and knee. This two-arm, parallel, double-blinded study involved 2546 patients
undergoing elective total hip (THA) and total knee arthroplasty
(TKA) at three hospitals. A total of 1323 were quasi-randomized
to a standard suture group, and 1223 being quasi-randomized to the
triclosan-coated suture group. The primary endpoint was the rate
of SSI at 30 days postoperatively.Aims
Patients and Methods
To validate the English language Forgotten Joint Score-12 (FJS-12)
as a tool to evaluate the outcome of hip and knee arthroplasty in
a United Kingdom population. All patients undergoing surgery between January and August 2014
were eligible for inclusion. Prospective data were collected from
205 patients undergoing total hip arthroplasty (THA) and 231 patients
undergoing total knee arthroplasty (TKA). Outcomes were assessed
with the FJS-12 and the Oxford Hip and Knee Scores (OHS, OKS) pre-operatively,
then at six and 12 months post-operatively. Internal consistency,
convergent validity, effect size, relative validity and ceiling
effects were determined.Aims
Patients and Methods
The diagnosis of periprosthetic joint infection (PJI) remains
demanding due to limitations of all the available diagnostic tests.
The synovial fluid marker, α-defensin, is a promising adjunct for
the assessment of potential PJI. The purpose of this study was to
investigate the qualitative assessment of α-defensin, using Synovasure
to detect or exclude periprosthetic infection in total joint arthroplasty. We studied 50 patients (28 women, 22 men, mean age 65 years;
20 to 89) with a clinical indication for revision arthroplasty who
met the inclusion criteria of this prospective diagnostic study.
The presence of α-defensin was determined using the qualitative
Synovasure test and compared with standard diagnostic methods for
PJI. Based on modified Musculoskeletal Infection Society (MSIS)
criteria, 13 cases were categorised as septic and 36 as aseptic revisions.
One test was inconclusive.Aims
Patients and Methods
The purpose of this study was to evaluate the
effect of various non-operative modalities of treatment (transcutaneous
electrical nerve stimulation (TENS); neuromuscular electrical stimulation
(NMES); insoles and bracing) on the pain of osteoarthritis (OA)
of the knee. We conducted a systematic review according to the Preferred Reporting
Items for Systematic Reviews and Meta-Analyses guidelines to identify
the therapeutic options which are commonly adopted for the management
of osteoarthritis (OA) of the knee. The outcome measurement tools used in the different studies were
the visual analogue scale and The Western Ontario and McMaster Universities
Arthritis Index pain index: all pain scores were converted to a
100-point scale. A total of 30 studies met our inclusion criteria: 13 on insoles,
seven on TENS, six on NMES, and four on bracing. The standardised
mean difference (SMD) in pain after treatment with TENS was 1.796,
which represented a significant reduction in pain. The significant
overall effect estimate for NMES on pain was similar to that of
TENS, with a SMD of 1.924. The overall effect estimate of insoles
on pain was a SMD of 0.992. The overall effect of bracing showed
a significant reduction in pain of 1.34. Overall, all four non-operative modalities of treatment were
found to have a significant effect on the reduction of pain in OA
of the knee. This study shows that non-operative physical modalities of treatment
are of benefit when treating OA of the knee. However, much of the
literature reviewed evaluates studies with follow-up of less than
six months: future work should aim to evaluate patients with longer
follow-up. Cite this article:
We examined the risk of thrombotic and major
bleeding events in patients undergoing total hip and knee replacement
(THR and TKR) treated with thromboprophylaxis, using nationwide
population-based databases. We identified 83 756 primary procedures
performed between 1997 and 2011. The outcomes were symptomatic venous thromboembolism
(VTE), myocardial infarction (MI), stroke, death and major bleeding
requiring hospitalisation within 90 days of surgery. A total of 1114 (1.3%) and 483 (0.6%) patients experienced VTE
and bleeding, respectively. The annual risk of VTE varied between
0.9% and 1.6%, and of bleeding between 0.4% and 0.8%. The risk of
VTE and bleeding was unchanged over a 15-year period. A total of
0.7% of patients died within 90 days, with a decrease from 1% in
1997 to 0.6% in 2011 (p <
0.001). A high level of comorbidity
and general anaesthesia were strong risk factors for both VTE and
bleeding, with no difference between THR and TKR patients. The risk
of both MI and stroke was 0.5%, which remained unchanged during
the study period. In this cohort study of patients undergoing THR and TKR patients
in routine clinical practice, approximately 3% experienced VTE,
MI, stroke or bleeding. These risks did not decline during the 15-year
study period, but the risk of dying fell substantially. Cite this article:
In order to compare the effect of oral apixaban
(a factor Xa inhibitor) with subcutaneous enoxaparin on major venous
thromboembolism and major and non-major clinically relevant bleeding
after total knee and hip replacement, we conducted a pooled analysis
of two previously reported double-blind randomised studies involving 8464
patients. One group received apixaban 2.5 mg twice daily (plus placebo
injection) starting 12 to 24 hours after operation, and the other
received enoxaparin subcutaneously once daily (and placebo tablets)
starting 12 hours (± 3) pre-operatively. Each regimen was continued
for 12 days ( Apixaban 2.5 mg twice daily is more effective than enoxaparin
40 mg once daily without increased bleeding.
We report a systematic review and meta-analysis
of the peer-reviewed literature focusing on metal sensitivity testing
in patients undergoing total joint replacement (TJR). Our purpose
was to assess the risk of developing metal hypersensitivity post-operatively
and its relationship with outcome and to investigate the advantages
of performing hypersensitivity testing. We undertook a comprehensive search of the citations quoted in
PubMed and EMBASE: 22 articles (comprising 3634 patients) met the
inclusion criteria. The frequency of positive tests increased after
TJR, especially in patients with implant failure or a metal-on-metal
coupling. The probability of developing a metal allergy was higher
post-operatively (odds ratio (OR) 1.52 (95% confidence interval
(CI) 1.06 to 2.31)), and the risk was further increased when failed
implants were compared with stable TJRs (OR 2.76 (95% CI 1.14 to
6.70)). Hypersensitivity testing was not able to discriminate between
stable and failed TJRs, as its predictive value was not statistically
proven. However, it is generally thought that hypersensitivity testing
should be performed in patients with a history of metal allergy
and in failed TJRs, especially with metal-on-metal implants and
when the cause of the loosening is doubtful.
The aim of this study was to evaluate whether
coating titanium discs with selenium in the form of sodium selenite decreased
bacterial adhesion of In order to evaluate bacterial adhesion, sterile titanium discs
were coated with increasing concentrations of selenium and incubated
with bacterial solutions of The tested Selenium coating is a promising method to reduce bacterial attachment
on prosthetic material. Cite this article:
We obtained information from the Elective Orthopaedic
Centre on 1523 patients with baseline and six-month Oxford hip scores
(OHS) after undergoing primary hip replacement (THR) and 1784 patients
with Oxford knee scores (OKS) for primary knee replacement (TKR)
who completed a six-month satisfaction questionnaire. Receiver operating characteristic curves identified an absolute
change in OHS of 14 points or more as the point that discriminates
best between patients’ satisfaction levels and an 11-point change
for the OKS. Satisfaction is highest (97.6%) in patients with an
absolute change in OHS of 14 points or more, compared with lower
levels of satisfaction (81.8%) below this threshold. Similarly,
an 11-point absolute change in OKS was associated with 95.4% satisfaction
compared with 76.5% below this threshold. For the six-month OHS
a score of 35 points or more distinguished patients with the highest
satisfaction level, and for the six-month OKS 30 points or more identified
the highest level of satisfaction. The thresholds varied according
to patients’ pre-operative score, where those with severe pre-operative
pain/function required a lower six-month score to achieve the highest
levels of satisfaction. Our data suggest that the choice of a six-month follow-up to
assess patient-reported outcomes of THR/TKR is acceptable. The thresholds
help to differentiate between patients with different levels of
satisfaction, but external validation will be required prior to
general implementation in clinical practice.
Between 1988 and 1998 we implanted 318 total hip replacements (THRs) in 287 patients using the Plasmacup (B. Braun Ltd, Sheffield, United Kingdom) and a conventional metal-on-polyethylene articulation. The main indications for THR were primary or secondary osteoarthritis. At follow-up after a mean 11.6 years (7.6 to 18.4) 17 patients had died and 20 could not be traced leaving a final series of 280 THRs in 250 patients. There were 62 revisions (22.1%) in 59 patients. A total of 43 acetabular shells (15.4%) had been revised and 13 (4.6%) had undergone exchange of the liner. The most frequent indications for revision were osteolysis and aseptic loosening, followed by polyethylene wear. The mean Kaplan-Meier survival of the Plasmacup was 91% at ten years and 58% at 14 years. Osteolysis was found around 36 (17.1%) of the 211 surviving shells. The median annual rate of linear wear in the surviving shells was 0.12 mm/year and 0.25 mm/year in those which had been revised (p <
0.001). Polyethylene wear was a strong independent risk factor for osteolysis and aseptic loosening. The percentage of patients with osteolysis increased proportionately with each quintile of wear-rate. There is a high late rate of failure of the Plasmacup. Patients with the combination of this prosthesis and bearing should be closely monitored after ten years.
Patients who have undergone total hip or knee replacement (THR and TKR, respectively) are at high risk of venous thromboembolism. We aimed to determine the time courses of both the incidence of venous thromboembolism and effective prophylaxis. Patients with elective primary THR and TKR were enrolled in the multi-national Global Orthopaedic Registry. Data on the incidence of venous thromboembolism and prophylaxis were collected from 6639 THR and 8326 TKR patients. The cumulative incidence of venous thromboembolism within three months of surgery was 1.7% in the THR and 2.3% in the TKR patients. The mean times to venous thromboembolism were 21.5 days ( The risk of venous thromboembolism extends beyond the usual period of hospitalisation, while the duration of prophylaxis is often shorter than this. Practices should be re-assessed to ensure that patients receive appropriate durations of prophylaxis.
The National Institute for Clinical Excellence (NICE) produces recommendations on appropriate treatment within the National Health Service (NHS) in England and Wales. The NICE guidelines on prophylaxis for venous thromboembolism in orthopaedic surgery recommend that all patients be offered a low molecular weight heparin (LMWH). The linked hospital episode statistics of 219 602 patients were examined to determine the rates of complications following lower limb arthroplasty for the 12-month periods prior to and following the publication of these guidelines. These were compared with data from the National Joint Registry (England and Wales) regarding the use of LMWH during the same periods. There was a significant increase in the reported use of LMWH (59.5% to 67.6%, p <
0.001) following the publication of the guidelines. However, the 90-day venous thromboembolism events actually increased slightly following total hip replacement (THR, 1.69% to 1.84%, p = 0.06) and remained unchanged following total knee replacement (TKR, 1.99% to 2.04%). Return to theatre in the first 30 days for infection did not show significant changes. There was an increase in the number of patients diagnosed with thrombocytopenia, which was significant following THR (0.11% to 0.16%, p = 0.04). The recommendations from NICE are based on predicted reductions in venous thromboembolism events, reducing morbidity, mortality and costs to the NHS. The early results in orthopaedic patients do not support these predictions, but do show an increase in complications.
We reviewed systematically the published evidence on the effectiveness of antibiotic prophylaxis for the reduction of wound infection in patients undergoing total hip and total knee replacement. Publications were identified using the Cochrane Library, MEDLINE, EMBASE and CINAHL databases. We also contacted authors to identify unpublished trials. We included randomised controlled trials which compared any prophylaxis with none, the administration of systemic antibiotics with that of those in cement, cephalosporins with glycopeptides, cephalosporins with penicillin-derivatives, and second-generation with first-generation cephalosporins. A total of 26 studies (11 343 participants) met the inclusion criteria. Methodological quality was variable. In a meta-analysis of seven studies (3065 participants) antibiotic prophylaxis reduced the absolute risk of wound infection by 8% and the relative risk by 81% compared with no prophylaxis (p <
0.00001). No other comparison showed a significant difference in clinical effect. Antibiotic prophylaxis should be routine in joint replacement but the choice of agent should be made on the basis of cost and local availability.
Bone cements produced by different manufacturers vary in their mechanical properties and antibiotic elution characteristics. Small changes in the formulation of a bone cement, which may not be apparent to surgeons, can also affect these properties. The supplier of Palacos bone cement with added gentamicin changed in 2005. We carried out a study to examine the mechanical characteristics and antibiotic elution of Schering-Plough Palacos, Heraeus Palacos and Depuy CMW Smartset bone cements. Both Heraeus Palacos and Smartset bone cements performed significantly better than Schering-Plough Palacos in terms of mechanical characteristics, with and without additional vancomycin (p <
0.001). All cements show a deterioration in flexural strength with increasing addition of vancomycin, albeit staying above ISO minimum levels. Both Heraeus Palacos and Smartset elute significantly more gentamicin cumulatively than Schering-Plough Palacos. Smartset elutes significantly more vancomycin cumulatively than Heraeus Palacos. The improved antibiotic elution characteristics of Smartset and Heraeus Palacos are not associated with a deterioration in mechanical properties. Although marketed as the ‘original’ Palacos, Heraeus Palacos has significantly altered mechanical and antibiotic elution characteristics compared with the most commonly-used previous version.
This prospective study evaluates the role of new laboratory markers in the diagnosis of deep implant infection in 78 patients (41 men and 37 women) with a revision total knee or hip replacement. The mean age at the time of operation was 64.0 years (19 to 90). Intra-operative cultures showed that 21 patients had a septic and 57 an aseptic total joint replacement. The white blood cell count, the erythrocyte sedimentation rate and levels of C-reactive protein, interleukin-6, procalcitonin and tumour necrosis factor (TNF)-α were measured in blood samples before operation. The diagnostic cut-off values were determined by Received Operating Characteristic curve analysis. C-reactive protein (>
3.2 md/dl) and interleukin-6 (>
12 pg/ml) have the highest sensitivity (0.95). Interleukin-6 is less specific than C-reactive protein (0.87 The combination of C-reactive protein and interleukin-6 measurement provide excellent screening tests for infection of a deep implant. A highly specific marker such as procalcitonin and pre-operative aspiration of the joint might be useful in identifying patients with true positive C-reactive protein and/or interleukin-6 levels.
We conducted a multicentre cohort study of 228 patients with osteoarthritis followed up after total hip or knee replacement. Quality of life and patient satisfaction were assessed by self-administered questionnaires. Patient satisfaction was the dependent variable in a multivariate linear regression model. Independent variables included sociodemographic factors, pre- and post-operative clinical characteristics and the pre-operative and post-discharge health-related quality of life. The mean age of the patients was 69 years ( The pre-operative health-related quality of life and patient characteristics have little effect on inpatient satisfaction with care. This suggests that the impact of the care process on satisfaction may be independent of observed and perceived initial patient-related characteristics.