Aims. Patient dissatisfaction following primary total knee arthroplasty (TKA) with manual jig-based instruments has been reported to be as high as 30%. Robotic-assisted total knee arthroplasty (RA-TKA) has been increasingly used in an effort to improve patient outcomes, however there is a paucity of literature examining patient satisfaction after RA-TKA. This study aims to identify the incidence of patients who were not satisfied following RA-TKA and to determine factors associated with higher levels of dissatisfaction. Methods. This was a retrospective review of 674 patients who underwent primary TKA between October 2016 and September 2020 with a minimum two-year follow-up. A five-point Likert satisfaction score was used to place patients into two groups: Group A were those who were very dissatisfied, dissatisfied, or neutral (Likert score 1 to 3) and Group B were those who were satisfied or very satisfied (Likert score 4 to 5). Patient demographic data, as well as preoperative and postoperative patient-reported outcome measures, were compared between groups. Results. Overall, 45 patients (6.7%) were in Group A and 629 (93.3%) were in Group B. Group A (vs Group B) had a higher proportion of male sex (p = 0.008), preoperative chronic opioid use (p < 0.001), preoperative psychotropic medication use (p = 0.01), prior anterior cruciate ligament (ACL) reconstruction (p < 0.001), and preoperative symptomatic lumbar spine disease (p = 0.004). Group A was also younger (p = 0.023).
Aims. Higher osteoblastic bone activity is expected in aseptic loosening and painful unicompartmental knee arthroplasty (UKA). However, insights into normal bone activity patterns after medial UKAs are lacking. The aim of this study was to identify the evolution in bone activity pattern in well-functioning medial mobile-bearing UKAs. Methods. In total, 34 patients (13 female, 21 male; mean age 62 years (41 to 79); BMI 29.7 kg/m. 2. (23.6 to 42.1)) with 38 medial Oxford partial UKAs (20 left, 18 right; 19 cementless, 14 cemented, and five hybrid) were prospectively followed with sequential 99mTc-hydroxymethane diphosphonate single photon emission CT (SPECT)/CT preoperatively, and at one and two years postoperatively. Changes in mean osteoblastic activity were investigated using a tracer localization scheme with volumes of interest (VOIs), reported by normalized mean tracer values. A SPECT/CT registration platform additionally explored cortical tracer evolution in zones of interest identified by previous experimental research. Results. Significant reduction of tracer activity from the preoperative situation was found in femoral and anteromedial tibial VOIs adjacent to the UKA components. Temporarily increased osteoblastic bone activity was observed in VOIs comprising the UKA keel structure at one year postoperatively compared to the preoperative activity. Persistent higher tracer uptake was found in the posterior tibial cortex at final follow-up.
Aims. In the last decade, perioperative advancements have expanded the use of outpatient primary total knee arthroplasty (TKA). Despite this, there remains limited data on expedited discharge after revision TKA. This study compared 30-day readmissions and reoperations in patients undergoing revision TKA with a hospital stay greater or less than 24 hours. The authors hypothesized that expedited discharge in select patients would not be associated with increased 30-day readmissions and reoperations. Methods. Aseptic revision TKAs in the National Surgical Quality Improvement Program database were reviewed from 2013 to 2020. TKAs were stratified by length of hospital stay (greater or less than 24 hours). Patient demographic details, medical comorbidities, American Society of Anesthesiologists (ASA) grade, operating time, components revised, 30-day readmissions, and reoperations were compared.
Aims. Unicompartmental knee arthroplasty (UKA) provides improved early functional outcomes and less postoperative morbidity and pain compared with total knee arthroplasty (TKA). Opioid prescribing has increased in the last two decades, and recently states in the USA have developed online Prescription Drug Monitoring Programs to prevent overprescribing of controlled substances. This study evaluates differences in opioid requirements between patients undergoing TKA and UKA. Patients and Methods. We retrospectively reviewed 676 consecutive TKAs and 241 UKAs. Opioid prescriptions in morphine milligram equivalents (MMEs), sedatives, benzodiazepines, and stimulants were collected from State Controlled Substance Monitoring websites six months before and nine months after the initial procedures. Bivariate and
Aims. The mobile bearing Oxford unicompartmental knee arthroplasty (OUKA) is recommended to be performed with the leg in the hanging leg (HL) position, and the thigh placed in a stirrup. This comparative cadaveric study assesses implant positioning and intraoperative kinematics of OUKA implanted either in the HL position or in the supine leg (SL) position. Methods. A total of 16 fresh-frozen knees in eight human cadavers, without macroscopic anatomical defects, were selected. The knees from each cadaver were randomized to have the OUKA implanted in the HL or SL position. Results. Tibial base plate rotation was significantly more variable in the SL group with 75% of tibiae mal-rotated.
Aims. The aim of this study was to investigate the incidence, risk factors, and outcome of venous thromboembolism (VTE) following anterior cruciate ligament (ACL) reconstruction in a nationwide cohort. Patients and Methods. All ACL reconstructions, primary and revision, that were recorded in the Swedish Knee Ligament Register (SKLR) between 2006 and 2013 were linked with data from the Swedish National Board of Health and Welfare. The incidence of VTE was determined by entries between the day of surgery until 90 days postoperatively based on diagnosis codes and the prescription of anticoagulants. Risk factors, outcome, and the use of thromboprophylaxis were analyzed. Descriptive statistics with
Aims. There is little information regarding the risk of a patient developing prosthetic joint infection (PJI) after primary total knee arthroplasty (TKA) when the patient has previously experienced PJI of a TKA or total hip arthroplasty (THA) in another joint. The goal of this study was to compare the risk of PJI of primary TKA in this patient population against matched controls. Patients and Methods. We retrospectively reviewed 95 patients (102 primary TKAs) treated between 2000 and 2014 with a history of PJI in another TKA or THA. A total of 50 patients (53%) were female. Mean age was 69 years (45 to 88) with a mean body mass index (BMI) of 36 kg/m. 2. (22 to 59). In total, 27% of patients were on chronic antibiotic suppression. Mean follow-up was six years (2 to 16). We 1:3 matched these (for age, sex, BMI, and surgical year) to 306 primary TKAs performed in 306 patients with a THA or TKA of another joint without a subsequent PJI. Competing risk with death was used for statistical
Aims. Little is known about employment following total knee arthroplasty
(TKA). This study aims to identify factors which predict return
to work following TKA in patients of working age in the United Kingdom. Patients &
Methods. We prospectively assessed 289 patients (289 TKAs) aged ≤ 65 years
who underwent TKA between 2010 and 2013. There were 148 women. The
following were recorded pre-operatively: age, gender, body mass
index, social deprivation, comorbidities, indication for surgery,
work status and nature of employment, activity level as assessed by
the University of California, Los Angeles (UCLA) activity score
and Oxford Knee Score (OKS). The intention of patients to return
to work or to retire was not assessed pre-operatively. At a mean
of 3.4 years (2 to 4) post-operatively, the return to work status,
OKS, the EuroQol-5 dimensions (EQ-5D) score, UCLA activity score
and Work, Osteoarthritis and joint-Replacement (WORQ) score were
obtained. Univariate and multivariate analyses were performed. Results. Of 261 patients (90%) who were working before TKA, 105 (40%)
returned to any job, including 89 (34%) who returned to the same
job at a mean of 13.5 weeks (2 to 104) post-operatively. A total
of 108 (41%) retired following TKA and 18 remained on welfare. Patients
not working before the operation did not return to work. Median
UCLA scores improved in 125 patients (58%) from 4 (mild activity)
to 6 (moderate activity) (p <
0.001). Significant
(p <
0.05) factors which were predictive of return to any work
included age, heavy or moderate manual work, better post-operative
UCLA, OKS and EQ-5D general health scores. Significant predictive
factors of return to the same work included age, heavy or moderate
manual work and post-operative OKS.
Aims. Risk of revision following total knee arthroplasty (TKA) is higher
in patients under 55 years, but little data are reported regarding
non-revision outcomes. This study aims to identify predictors of
dissatisfaction in these patients. Patients and Methods. We prospectively assessed 177 TKAs (157 consecutive patients,
99 women, mean age 50 years; 17 to 54) from 2008 to 2013. Age, gender,
implant, indication, body mass index (BMI), social deprivation,
range of movement, Kellgren-Lawrence (KL) grade of osteoarthritis
(OA) and prior knee surgery were recorded. Pre- and post-operative
Oxford Knee Score (OKS) as well as Short Form-12 physical (PCS)
and mental component scores were obtained. Post-operative range
of movement, complications and satisfaction were measured at one
year. Results . Overall, 44 patients with 44 TKAs (24.9%) under 55 years of age
were unsure or dissatisfied with their knee. Significant predictors
of dissatisfaction on univariate analysis included: KL grade 1/2
OA (59% dissatisfied), poor pre-operative OKS, complications, poor
improvements in PCS and OKS and indication (primary OA 19% dissatisfied,
previous meniscectomy 41%, multiply operated 42%, other surgery
29%, BMI >
40 kg/m. 2. 31%, post-traumatic OA 45%, and inflammatory
arthropathy 5%). Poor pre-operative OKS, poor improvement in OKS
and post-operative stiffness independently predicted dissatisfaction
on
Aims. Debate continues regarding the optimum management of periprosthetic distal femoral fractures (PDFFs). This study aims to determine which operative treatment is associated with the lowest perioperative morbidity and mortality when treating low (Su type II and III) PDFFs comparing lateral locking plate fixation (LLP-ORIF) or distal femoral arthroplasty (DFA). Methods. This was a retrospective cohort study of 60 consecutive unilateral (PDFFs) of Su types II (40/60) and III (20/60) in patients aged ≥ 60 years: 33 underwent LLP-ORIF (mean age 81.3 years (SD 10.5), BMI 26.7 (SD 5.5); 29/33 female); and 27 underwent DFA (mean age 78.8 years (SD 8.3); BMI 26.7 (SD 6.6); 19/27 female). The primary outcome measure was reoperation. Secondary outcomes included perioperative complications, calculated blood loss, transfusion requirements, functional mobility status, length of acute hospital stay, discharge destination and mortality. Kaplan-Meier survival analysis was performed. Cox
This multicentre retrospective observational study’s aims were to investigate whether there are differences in the occurrence of radiolucent lines (RLLs) following total knee arthroplasty (TKA) between the conventional Attune baseplate and its successor, the novel Attune S+, independent from other potentially influencing factors; and whether tibial baseplate design and presence of RLLs are associated with differing risk of revision. A total of 780 patients (39% male; median age 70.7 years (IQR 62.0 to 77.2)) underwent cemented TKA using the Attune Knee System) at five centres, and with the latest radiograph available for the evaluation of RLL at between six and 36 months from surgery. Univariate and multivariate logistic regression models were performed to assess associations between patient and implant-associated factors on the presence of tibial and femoral RLLs. Differences in revision risk depending on RLLs and tibial baseplate design were investigated with the log-rank test.Aims
Methods
Despite new technologies for total knee arthroplasty (TKA), approximately 20% of patients are dissatisfied. A major reason for dissatisfaction and revision surgery after TKA is persistent pain. The radiological grade of osteoarthritis (OA) preoperatively has been investigated as a predictor of the outcome after TKA, with conflicting results. The aim of this study was to determine if there is a difference in the intensity of pain 12 months after TKA in relation to the preoperative radiological grade of OA alone, and the combination of the intensity of preoperative pain and radiological grade of OA. The preoperative data of 300 patients who underwent primary TKA were collected, including clinical information (age, sex, preoperative pain), psychological variables (depression, anxiety, pain catastrophizing, anticipated pain), and quantitative sensory testing (temporal summation, pressure pain thresholds, conditioned pain modulation). The preoperative radiological severity of OA was graded according to the Kellgren-Lawrence (KL) classification. Persistent pain in the knee was recorded 12 months postoperatively. Generalized linear models explored differences in postoperative pain according to the KL grade, and combined preoperative pain and KL grade. Relative risk models explored which preoperative variables were associated with the high preoperative pain/low KL grade group.Aims
Methods
Aims. The primary aim of this study was to assess whether pain in the contralateral knee had a clinically significant influence on the outcome of total knee arthroplasty (TKA) according to the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score. Secondary aims were to: describe the prevalence of contralateral knee pain; identify if it clinically improves after TKA; and assess whether contralateral knee pain independently influences patient satisfaction with their TKA. Methods. A retrospective cohort of 3,178 primary TKA patients were identified from an arthroplasty database. Patient characteristics, comorbidities, and WOMAC scores were collected preoperatively and one year postoperatively for the index knee. In addition, WOMAC pain scores were also collected for the contralateral knee. Overall patient satisfaction was assessed at one year. Preoperative contralateral knee pain was defined according to the WOMAC score: minimal (> 78 points), mild (59 to 78), moderate (44 to 58), and severe (< 44).
Despite recent literature questioning their use, vancomycin and clindamycin often substitute cefazolin as the preoperative antibiotic prophylaxis in primary total knee arthroplasty (TKA), especially in the setting of documented allergy to penicillin. Topical povidone-iodine lavage and vancomycin powder (VIP) are adjuncts that may further broaden antimicrobial coverage, and have shown some promise in recent investigations. The purpose of this study, therefore, is to compare the risk of acute periprosthetic joint infection (PJI) in primary TKA patients who received cefazolin and VIP to those who received a non-cephalosporin alternative and VIP. This was a retrospective cohort study of 11,550 primary TKAs performed at an orthopaedic hospital between 2013 and 2019. The primary outcome was PJI occurring within 90 days of surgery. Patients were stratified into two groups (cefazolin vs non-cephalosporin) based on their preoperative antibiotic. All patients also received the VIP protocol at wound closure. Bivariate and multiple logistic regression analyses were performed to control for potential confounders and identify the odds ratio of PJI.Aims
Methods
We report a prospective study, using
Wear of the polyethylene (PE) tibial insert of total knee arthroplasty (TKA) increases the risk of revision surgery with a significant cost burden on the healthcare system. This study quantifies wear performance of tibial inserts in a large and diverse series of retrieved TKAs to evaluate the effect of factors related to the patient, knee design, and bearing material on tibial insert wear performance. An institutional review board-approved retrieval archive was surveyed for modular PE tibial inserts over a range of in vivo duration (mean 58 months (0 to 290)). Five knee designs, totalling 1,585 devices, were studied. Insert wear was estimated from measured thickness change using a previously published method. Linear regression statistical analyses were used to test association of 12 patient and implant design variables with calculated wear rate.Aims
Methods
It has been shown that the preoperative modification of risk factors associated with obesity may reduce complications after total knee arthroplasty (TKA). However, the optimal method of doing so remains unclear. The aim of this study was to investigate whether a preoperative Risk Stratification Tool (RST) devised in our institution could reduce unexpected intensive care unit (ICU) transfers and 90-day emergency department (ED) visits, readmissions, and reoperations after TKA in obese patients. We retrospectively reviewed 1,614 consecutive patients undergoing primary unilateral TKA. Their mean age was 65.1 years (17.9 to 87.7) and the mean BMI was 34.2 kg/m2 (SD 7.7). All patients underwent perioperative optimization and monitoring using the RST, which is a validated calculation tool that provides a recommendation for postoperative ICU care or increased nursing support. Patients were divided into three groups: non-obese (BMI < 30 kg/m2, n = 512); obese (BMI 30 kg/m2 to 39.9 kg/m2, n = 748); and morbidly obese (BMI > 40 kg/m2, n = 354). Logistic regression analysis was used to evaluate the outcomes among the groups adjusted for age, sex, smoking, and diabetes.Aims
Methods
The COVID-19 pandemic led to a swift adoption of telehealth in orthopaedic surgery. This study aimed to analyze the satisfaction of patients and surgeons with the rapid expansion of telehealth at this time within the division of adult reconstructive surgery at a major urban academic tertiary hospital. A total of 334 patients underging arthroplasty of the hip or knee who completed a telemedicine visit between 30 March and 30 April 2020 were sent a 14-question survey, scored on a five-point Likert scale. Eight adult reconstructive surgeons who used telemedicine during this time were sent a separate 14-question survey at the end of the study period. Factors influencing patient satisfaction were determined using univariate and multivariate ordinal logistic regression modelling.Aims
Methods
Up to 20% of patients are not satisfied with the outcome following total knee replacement (TKR). This study investigated the pre- and post-operative predictors of dissatisfaction in a large cohort of patients undergoing TKR. We assessed 1217 consecutive patients between 2006 and 2008 both before operation and six months after, using the Short-form (SF)-12 health questionnaire and the Oxford Knee Score. Detailed information concerning comorbidity was also gathered. Satisfaction was measured at one year when 18.6% (226 of 1217) of patients were unsure or dissatisfied with their replacement and 81.4% (911 of 1217) were satisfied or very satisfied.
Although total knee arthroplasty (TKA) is a highly successful procedure, about 20% of patients remain dissatisfied postoperatively. This proportion is derived from dichotomous models of the assessment of surgical success or failure, which may not reflect the spectrum of outcomes. The aim of this study was to explore differing responses to surgery, and assess whether there are distinct groups of patients with differing patterns of outcome. This was a secondary analysis of a UK multicentre TKA longitudinal cohort study. We used a group-based trajectory modelling analysis of Oxford Knee Score (OKS) in the first year following surgery with longitudinal data involving five different timepoints and multiple predictor variables. Associations between the derived trajectory groups and categorical baseline variables were assessed, and predictors of trajectory group membership were identified using Poisson regression and multinomial logistic regression, as appropriate. The final model was adjusted for sociodemographic factors (age, sex) and baseline OKS.Aims
Methods
To establish our early clinical results of a new total knee arthroplasty (TKA) tibial component introduced in 2013 and compare it to other designs in use at our hospital during the same period. This is a retrospective study of 166 (154 patients) consecutive cemented, fixed bearing, posterior-stabilized (PS) TKAs (ATTUNE) at one hospital performed by five surgeons. These were compared with a reference cohort of 511 knees (470 patients) of other designs (seven manufacturers) performed at the same hospital by the same surgeons. There were no significant differences in age, sex, BMI, or follow-up times between the two cohorts. The primary outcome was revision performed or pending.Aims
Methods
Patients with a deformity of the hindfoot present a particular challenge when performing total knee arthroplasty (TKA). The literature contains little information about the relationship between TKA and hindfoot alignment. This systematic review aimed to determine from both clinical and radiological studies whether TKA would alter a preoperative hindfoot deformity and whether the outcome of TKA is affected by the presence of a postoperative hindfoot deformity. A systematic literature search was performed in the databases PubMed, EMBASE, Cochrane Library, and Web of Science. Search terms consisted of “total knee arthroplasty/replacement” combined with “hindfoot/ankle alignment”. Inclusion criteria were all English language studies analyzing the association between TKA and the alignment of the hindfoot, including the clinical or radiological outcomes. Exclusion criteria consisted of TKA performed with a concomitant extra-articular osteotomy and case reports or expert opinions. An assessment of quality was conducted using the modified Methodological Index for Non-Randomized Studies (MINORS). The review was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guidelines and registered in the PROSPERO database (CRD42019106980).Aims
Methods
While patients with psychological distress have poorer short-term outcomes after total knee arthroplasty (TKA), their longer-term function is unknown. We aimed to 1) assess the influence of preoperative mental health status on long-term functional outcomes, quality of life, and patient satisfaction; and 2) analyze the change in mental health after TKA, in a cohort of patients with no history of mental health disorder, with a minimum of ten years’ follow-up. Prospectively collected data of 122 patients undergoing primary unilateral TKA in 2006 were reviewed. Patients were assessed pre- and postoperatively at two and ten years using the Knee Society Knee Score (KSKS) and Function Score (KSFS); Oxford Knee Score (OKS); and the Mental (MCS) and Physical Component Summary (PCS) which were derived from the 36-Item Short-Form Health Survey questionnaire (SF-36). Patients were stratified into those with psychological distress (MCS < 50, n = 51) and those without (MCS ≥ 50, n = 71). Multiple regression was used to control for age, sex, BMI, Charlson Comorbidity Index (CCI), and baseline scores. The rate of expectation fulfilment and satisfaction was compared between patients with low and high MCS.Aims
Methods
It remains controversial whether patellofemoral joint pathology is a contraindication to lateral unicompartmental knee arthroplasty (UKA). This study aimed to evaluate the effect of preoperative radiological degenerative changes and alignment on patient-reported outcome scores (PROMs) after lateral UKA. Secondarily, the influence of lateral UKA on the alignment of the patellofemoral joint was studied. A consecutive series of patients who underwent robotic arm-assisted fixed-bearing lateral UKA with at least two-year follow-up were retrospectively reviewed. Radiological evaluation was conducted to obtain a Kellgren Lawrence (KL) grade, an Altman score, and alignment measurements for each knee. Postoperative PROMs were assessed using the Kujala (Anterior Knee Pain Scale) score, Knee Injury and Osteoarthritis Outcome Score Joint Replacement (KOOS JR), and satisfaction levels.Aims
Methods
Our aim was to compare the degree of patellar descent and alteration in angle of the inclination of the tibial plateau in lateral closing-wedge and medial opening-wedge high tibial osteotomy (HTO) in 51 consecutive patients with osteoarthritis of the medial compartment and varus malalignment. Patellar height was measured by the Insall-Salvati (IS) and the Blackburne-Peel (BP) ratios. The tibial inclination was determined by the Moore-Harvey (MH) method.
The purpose of this investigation was to determine the relationship between height, weight, and sex with implant size in total knee arthroplasty (TKA) using a multivariate linear regression model and a Bayesian model. A retrospective review of an institutional registry was performed of primary TKAs performed between January 2005 and December 2016. Patient demographics including patient age, sex, height, weight, and body mass index (BMI) were obtained from registry and medical record review. In total, 8,100 primary TKAs were included. The mean age was 67.3 years (SD 9.5) with a mean BMI of 30.4 kg/m2 (SD 6.3). The TKAs were randomly split into a training cohort (n = 4,022) and a testing cohort (n = 4,078). A multivariate linear regression model was created on the training cohort and then applied to the testing cohort . A Bayesian model was created based on the frequencies of implant sizes in the training cohort. The model was then applied to the testing cohort to determine the accuracy of the model at 1%, 5%, and 10% tolerance of inaccuracy.Aims
Methods
The outcomes of total knee arthroplasty (TKA) depend on many factors. The impact of implant design on patient-reported outcomes is unknown. Our goal was to evaluate the patient-reported outcomes and satisfaction after primary TKA in patients with osteoarthritis undergoing primary TKA using five different brands of posterior-stabilized implant. Using our institutional registry, we identified 4135 patients who underwent TKA using one of the five most common brands of implant. These included Biomet Vanguard (Zimmer Biomet, Warsaw, Indiana) in 211 patients, DePuy/Johnson & Johnson Sigma (DePuy Synthes, Raynham, Massachusetts) in 222, Exactech Optetrak Logic (Exactech, Gainesville, Florida) in 1508, Smith & Nephew Genesis II (Smith & Nephew, London, United Kingdom) in 1415, and Zimmer NexGen (Zimmer Biomet) in 779 patients. Patients were evaluated preoperatively using the Knee Injury and Osteoarthritis Outcome Score (KOOS), Lower Extremity Activity Scale (LEAS), and 12-Item Short-Form Health Survey questionnaire (SF-12). Demographics including age, body mass index, Charlson Comorbidity Index, American Society of Anethesiologists status, sex, and smoking status were collected. Postoperatively, two-year KOOS, LEAS, SF-12, and satisfaction scores were compared between groups.Aims
Patients and Methods
This study compares the PFC total knee arthroplasty (TKA) system in a prospective randomized control trial (RCT) of the mobile-bearing rotating-platform (RP) TKA against the fixed-bearing (FB) TKA. This is the largest RCT with the longest follow-up where cruciate-retaining PFC total knee arthroplasties are compared in a non-bilateral TKA study. A total of 167 patients (190 knees with 23 bilateral cases), were recruited prospectively and randomly assigned, with 91 knees receiving the RP and 99 knees receiving FB. The mean age was 65.5 years (48 to 82), the mean body mass index (BMI) was 29.7 kg/m2 (20 to 52) and 73 patients were female. The Knee Society Score (KSS), Knee Society Functional Score (KSFS), Oxford Knee Score (OKS), Western Ontario and McMaster Universities Arthritis Index (WOMAC), and 12-Item Short-Form Health Survey Physical and Mental Component Scores (SF-12 PCS, SF-12 MCS) were gathered and recorded preoperatively, at five-years’ follow-up, and at ten years’ follow-up. Additionally, Knee Injury and Osteoarthritis Outcome Scores (KOOS) were collected at five- and ten-year follow-ups. The prevalence of radiolucent lines (RL) on radiographs and implant survival were recorded at five- and ten-year follow-ups.Aims
Patients and Methods
The purpose of this study was to compare outcomes of combined total joint arthroplasty (TJA) (total hip arthroplasty (THA) and total knee arthroplasty (TKA) performed during the same admission) versus bilateral THA, bilateral TKA, single THA, and single TKA. Combined TJAs performed on the same day were compared with those staged within the same admission episode. Data from the National (Nationwide) Inpatient Sample recorded between 2005 and 2014 were used for this retrospective cohort study. Postoperative in-hospital complications, total costs, and discharge destination were reviewed. Logistic and linear regression were used to perform the statistical analyses. p-values less than 0.05 were considered statistically significant.Aims
Patients and Methods
The purpose of this study was to evaluate trends in opioid use
after unicompartmental knee arthroplasty (UKA), to identify predictors
of prolonged use and to compare the rates of opioid use after UKA,
total knee arthroplasty (TKA) and total hip arthroplasty (THA). We identified 4205 patients who had undergone UKA between 2007
and 2015 from the Humana Inc. administrative claims database. Post-operative
opioid use for one year post-operatively was assessed using the
rates of monthly repeat prescription. These were then compared between
patients with and without a specific variable of interest and with
those of patients who had undergone TKA and THA.Aims
Materials and Methods
The aim of this study was to identify risk factors for prosthetic
joint infection (PJI) following total knee arthroplasty (TKA). The New Zealand Joint Registry database was analysed, using revision
surgery for PJI at six and 12 months after surgery as primary outcome
measures. Statistical associations between revision for infection,
with common and definable surgical and patient factors were tested.Aims
Patients and Methods
We present detailed information about early morbidity
after aseptic revision knee replacement from a nationwide study.
All aseptic revision knee replacements undertaken between 1st October
2009 and 30th September 2011 were analysed using the Danish National
Patient Registry with additional information from the Danish Knee
Arthroplasty Registry. The 1218 revisions involving 1165 patients
were subdivided into total revisions, large partial revisions, partial
revisions and revisions of unicondylar replacements (UKR revisions).
The mean age was 65.0 years (27 to 94) and the median length of
hospital stay was four days (interquartile range: 3 to 5), with
a 90 days re-admission rate of 9.9%,
re-operation rate of 3.5% and mortality rate of 0.2%. The age ranges
of 51 to 55 years (p = 0.018), 76 to 80 years (p <
0.001) and ≥ 81
years (p <
0.001) were related to an increased risk of re-admission.
The age ranges of 76 to 80 years (p = 0.018) and the large partial
revision subgroup (p = 0.073) were related to an increased risk
of re-operation. The ages from 76 to 80 years (p <
0.001), age ≥ 81
years (p <
0.001) and surgical time >
120 min (p <
0.001)
were related to increased length of hospital stay, whereas the use
of a tourniquet (p = 0.008) and surgery in a low volume centre (p
= 0.013) were related to shorter length of stay. In conclusion, we found a similar incidence of early post-operative
morbidity after aseptic knee revisions as has been reported after
primary procedures. This suggests that a length of hospital stay ≤ four
days and discharge home at that time is safe following aseptic knee
revision surgery in Denmark. Cite this article:
Patellofemoral arthroplasty (PFA) has experienced significant
improvements in implant survivorship with second generation designs.
This has renewed interest in PFA as an alternative to total knee
arthroplasty (TKA) for younger active patients with isolated patellofemoral
osteoarthritis (PF OA). We analysed the cost-effectiveness of PFA We used a Markov transition state model to compare cost-effectiveness
between PFA and TKA. Simulated patients were aged 60 (base case)
and 50 years. Lifetime costs (2015 United States dollars), quality-adjusted
life year (QALY) gains and incremental cost-effectiveness ratio
(ICER) were calculated from a healthcare payer perspective. Annual rates
of revision were derived from the National Joint Registry for England,
Wales, Northern Ireland and the Isle of Man. Deterministic and probabilistic
sensitivity analysis was performed for all parameters against a
$50 000/QALY willingness to pay. Aims
Patients and Methods
Preservation of posterior condylar offset (PCO) has been shown to correlate with improved functional results after primary total knee arthroplasty (TKA). Whether this is also the case for revision TKA, remains unknown. The aim of this study was to assess the independent effect of PCO on early functional outcome after revision TKA. A total of 107 consecutive aseptic revision TKAs were performed by a single surgeon during an eight-year period. The mean age was 69.4 years (39 to 85) and there were 59 female patients and 48 male patients. The Oxford Knee Score (OKS) and Short-form (SF)-12 score were assessed pre-operatively and one year post-operatively. Patient satisfaction was also assessed at one year. Joint line and PCO were assessed radiographically at one year.Objectives
Methods
The aim of this study was to evaluate the risk
factors for dislocation of the bearing after a mobile-bearing Oxford medial
unicompartmental knee replacement (UKR) and to test the hypothesis
that surgical factors, as measured from post-operative radiographs,
are associated with its dislocation From a total of 480 UKRs performed between 2001 and 2012, in
391 patients with a mean age of 66.5 years (45 to 82) (316 female,
75 male), we identified 17 UKRs where bearing dislocation occurred.
The post-operative radiological measurements of the 17 UKRs and
51 matched controls were analysed using conditional logistic regression analysis.
The post-operative radiological measurements included post-operative
change in limb alignment, the position of the femoral and tibial
components, the resection depth of the proximal tibia, and the femoral component-posterior
condyle classification. We concluded that a post-operative decrease in the posterior
tibial slope relative to the pre-operative value was the only significant
determinant of dislocation of the bearing after medial Oxford UKR
(odds ratio 1.881; 95% confidence interval 1.272 to 2.779). A post-operative
posterior tibial slope <
8.45° and a difference between the pre-operative
and post-operative posterior tibial slope of >
2.19° may increase
the risk of dislocation. Cite this article:
Analysis of the morphology of the distal femur, and by extension
of the femoral components in total knee arthroplasty (TKA), has
largely been related to the aspect ratio, which represents the width
of the femur. Little is known about variations in trapezoidicity
(i.e. whether the femur is more rectangular or more trapezoidal).
This study aimed to quantify additional morphological characteristics
of the distal femur and identify anatomical features associated
with higher risks of over- or under-sizing of components in TKA. We analysed the shape of 114 arthritic knees at the time of primary
TKA using the pre-operative CT scans. The aspect ratio and trapezoidicity
ratio were quantified, and the post-operative prosthetic overhang
was calculated. We compared the morphological characteristics with
those of 12 TKA models.Aims
Methods
The optimal timing of total knee replacement
(TKR) in patients with osteoarthritis, in relation to the severity
of disease, remains controversial. This prospective study was performed
to investigate the effect of the severity of osteoarthritis and
other commonly available pre- and post-operative clinical parameters
on the clinical outcome in a consecutive series of cemented TKRs.
A total of 176 patients who underwent unilateral TKR were included
in the study. Their mean age was 68 years (39 to 91), 63 (36%) were
male and 131 knees (74%) were classified as grade 4 on the Kellgren–Lawrence
osteoarthritis scale. A total of 154 patients (87.5%) returned for
clinical review 12 months post-operatively, at which time the outcome
was assessed using the Knee Society score. A low radiological severity of osteoarthritis was not associated
with pain 12 months post-operatively. However, it was significantly
associated with an inferior level of function (p = 0.007), implying
the need for increased focus on all possible reasons for pain in
the knee and the forms of conservative treatment which are available
for patients with lower radiological severity of osteoarthritis. Cite this article:
The aim of this study was to examine the functional
outcome at ten years following lateral closing wedge high tibial osteotomy
for medial compartment osteoarthritis of the knee and to define
pre-operative predictors of survival and determinants of functional
outcome. 164 consecutive patients underwent high tibial osteotomy between
2000 and 2002. A total of 100 patients (100 knees) met the inclusion
criteria and 95 were available for review at ten years. Data were
collected prospectively and included patient demographics, surgical
details, long leg alignment radiographs, Western Ontario and McMaster Universities
osteoarthritis index (WOMAC) and Knee Society scores (KSS) pre-operatively
and at five and ten years follow-up. At ten years, 21 patients had been revised at a mean of five
years. Overall Kaplan–Meier survival was 87% (95% confidence interval
(CI) 81 to 94) and 79% (95% CI 71 to 87) at five and ten years,
respectively. When compared with unrevised patients, those who had
been revised had significantly lower mean pre-operative WOMAC Scores
(47 (21 to 85) This study has shown that improved survival is associated with
age <
55 years, pre-operative WOMAC scores >
45 and, a BMI <
30. In patients over 55 years of age with adequate pre-operative
functional scores, survival can be good and functional outcomes
can be significantly better than their younger counterparts. We
recommend the routine use of pre-operative functional outcome scores
to guide decision-making when considering suitability for high tibial osteotomy. Cite this article:
We have investigated whether shape of the knee
can predict the clinical outcome of patients after an anterior cruciate
ligament rupture. We used statistical shape modelling to measure
the shape of the knee joint of 182 prospectively followed patients
on lateral and Rosenberg view radiographs of the knee after a rupture
of the anterior cruciate ligament. Subsequently, we associated knee
shape with the International Knee Documentation Committee subjective
score at two years follow-up. The mean age of patients was 31 years
(21 to 51), the majority were male (n = 121) and treated operatively
(n = 135). We found two modes (shape variations) that were significantly
associated with the subjective score at two years: one for the operatively
treated group (p = 0.002) and one for the non-operatively treated
group (p = 0.003). Operatively treated patients who had higher subjective
scores had a smaller intercondylar notch and a smaller width of
the intercondylar eminence. Non-operatively treated patients who
scored higher on the subjective score had a more pyramidal intercondylar
notch as opposed to one that was more dome-shaped. We conclude that
the shape of the femoral notch and the intercondylar eminence is predictive
of clinical outcome two years after a rupture of the anterior cruciate
ligament. Cite this article:
We used immediate post-operative The bending angles in the sagittal and axial planes were significantly
greater but the coronal-bending angle was significantly less in
the transtibial group than in the anteromedial portal and outside-in
groups (p <
0.001 each). The mean length of the femoral tunnel
in all three planes was significantly greater in the transtibial
group than the anteromedial portal and outside-in groups (p <
0.001 each), but all mean tunnel lengths in the three groups exceeded
30 mm. The only significant difference was the coronal graft- bending
angle in the anteromedial portal and outside-in groups (23.5° Compared with the transtibial technique, the anteromedial portal
and outside-in techniques may reduce the graft-bending stress at
the opening of the femoral tunnel. Despite the femoral tunnel length
being shorter in the anteromedial portal and outside-in techniques
than in the transtibial technique, a femoral tunnel length of more than
30 mm in the anteromedial portal and outside-in techniques may be
sufficient for the graft to heal. Cite this article:
We assessed the effect of social deprivation
upon the Oxford knee score (OKS), the Short-Form 12 (SF-12) and patient
satisfaction after total knee replacement (TKR). An analysis of
966 patients undergoing primary TKR for symptomatic osteoarthritis
(OA) was performed. Social deprivation was assessed using the Scottish
Index of Multiple Deprivation. Those patients that were most deprived
underwent surgery at an earlier age (p = 0.018), were more likely
to be female (p = 0.046), to endure more comorbidities (p = 0.04)
and to suffer worse pain and function according to the OKS (p <
0.001). In addition, deprivation was also associated with poor mental
health (p = 0.002), which was assessed using the mental component
(MCS) of the SF-12 score. Multivariable analysis was used to identify
independent predictors of outcome at one year. Pre-operative OKS,
SF-12 MCS, back pain, and four or more comorbidities were independent
predictors of improvement in the OKS (all p <
0.001). Pre-operative
OKS and improvement in the OKS were independent predictors of dissatisfaction
(p = 0.003 and p <
0.001, respectively). Although improvement
in the OKS and dissatisfaction after TKR were not significantly
associated with social deprivation Cite this article:
This study demonstrates a significant correlation
between the American Knee Society (AKS) Clinical Rating System and
the Oxford Knee Score (OKS) and provides a validated prediction
tool to estimate score conversion. A total of 1022 patients were prospectively clinically assessed
five years after TKR and completed AKS assessments and an OKS questionnaire.
Multivariate regression analysis demonstrated significant correlations between
OKS and the AKS knee and function scores but a stronger correlation
(r = 0.68, p <
0.001) when using the sum of the AKS knee and
function scores. Addition of body mass index and age (other statistically
significant predictors of OKS) to the algorithm did not significantly
increase the predictive value. The simple regression model was used to predict the OKS in a
group of 236 patients who were clinically assessed nine to ten years
after TKR using the AKS system. The predicted OKS was compared with
actual OKS in the second group. Intra-class correlation demonstrated
excellent reliability (r = 0.81, 95% confidence intervals 0.75 to
0.85) for the combined knee and function score when used to predict
OKS. Our findings will facilitate comparison of outcome data from
studies and registries using either the OKS or the AKS scores and
may also be of value for those undertaking meta-analyses and systematic
reviews. Cite this article:
We investigated whether an asymmetric extension
gap seen on routine post-operative radiographs after primary total
knee replacement (TKR) is associated with pain at three, six, 12
and 24 months’ follow-up. On radiographs of 277 patients after primary
TKR we measured the distance between the tibial tray and the femoral
condyle on both the medial and lateral sides. A difference was defined
as an asymmetric extension gap. We considered three groups (no asymmetric
gap, medial-opening and lateral-opening gap) and calculated the
associations with the Western Ontario and McMaster Universities
osteoarthritis index pain scores over time. Those with an asymmetric extension gap of ≥ 1.5 mm had a significant
association with pain scores at three months’ follow-up; patients
with a medial-opening extension gap reported more pain and patients
with a lateral-opening extension gap reported less pain (p = 0.036).
This effect was still significant at six months (p = 0.044), but had
lost significance by 12 months (p = 0.924). When adjusting for multiple
cofounders the improvement in pain was more pronounced in patients
with a lateral-opening extension gap than in those with a medial-opening extension
gap at three (p = 0.037) and six months’ (p = 0.027) follow-up. Cite this article:
We compared the incidence and severity of complications during and after closing- and opening-wedge high tibial osteotomy used for the treatment of varus arthritis of the knee, and identified the risk factors associated with the development of complications. In total, 104 patients underwent laterally based closing-wedge and 90 medial opening-wedge high tibial osteotomy between January 1993 and December 2006. The characteristics of each group were similar. All the patients were followed up for more than 12 months. We assessed the outcome using the Hospital for Special Surgery knee score, and recorded the complications. Age, gender, obesity (body mass index >
27.5 kg/m2), the type of osteotomy (closing The mean Hospital for Special Surgery score in the closing and opening groups improved from 73.4 (54 to 86) to 91.8 (81 to 100) and from 73.8 (56 to 88) to 93 (84 to 100), respectively. The incidence of complications overall and of major complications in both groups was not significantly different (p = 0.20 overall complication, p = 0.29 major complication). Logistic regression analysis adjusting for obesity and the pre-operative mechanical axis showed that obesity remained a significant independent risk factor (odds ratio = 3.23) of a major complication after high tibial osteotomy. Our results suggest that the opening-wedge high tibial osteotomy can be an alternative treatment option for young patients with medial compartment osteoarthritis and varus deformity.
We systematically reviewed the published literature
on the complications of closing wedge high tibial osteotomy for
the treatment of unicompartmental osteoarthritis of the knee. Publications
were identified using the Cochrane Library, MEDLINE, EMBASE and
CINAHL databases up to February 2012. We assessed randomised (RCTs), controlled
group clinical (CCTs) trials, case series in publications associated
with closing wedge osteotomy of the tibia in patients with osteoarthritis
of the knee and finally a Cochrane review. Many of these trials
included comparative studies (opening wedge
We undertook a study to determine the rates of infection and revision of total knee replacement (TKR) in patients with renal failure, renal transplantation and those undergoing renal dialysis in Scotland. The overall early and late infection rates were 1.10% and 2.19% compared with 1.06% and 2.01%, respectively, for non-renal patients. Patients with renal failure had a significantly increased risk of early infection (1.6%, relative risk 1.52, p = 0.002) and late infection (4.47%, relative risk 2.22, p <
0.001). Those on renal dialysis had significantly increased risks of late infection (8.03%, relative risk 3.99, p <
0.001) and early revision (3.70%, relative risk 4.40, p <
0.001). Renal transplant patients had a significantly increased risk of late infection, regardless of whether renal transplantation occurred before TKR (9.09%, relative risk 4.517, p = 0.027) or at any time (8.0%, relative risk 3.975, p = 0.047). There were significantly increased rates of comorbidities associated with infection for all the renal patient groups. Logistic regression analysis showed that renal failure and renal dialysis were independent risk factors for early infection and revision, respectively.
This study compared the outcome of total knee
replacement (TKR) in adult patients with fixed- and mobile-bearing prostheses
during the first post-operative year and at five years’ follow-up,
using gait parameters as a new objective measure. This double-blind
randomised controlled clinical trial included 55 patients with mobile-bearing (n
= 26) and fixed-bearing (n = 29) prostheses of the same design,
evaluated pre-operatively and post-operatively at six weeks, three
months, six months, one year and five years. Each participant undertook
two walking trials of 30 m and completed the EuroQol questionnaire,
Western Ontario and McMaster Universities osteoarthritis index,
Knee Society score, and visual analogue scales for pain and stiffness.
Gait analysis was performed using five miniature angular rate sensors
mounted on the trunk (sacrum), each thigh and calf. The study population
was divided into two groups according to age (≤ 70 years Improvements in most gait parameters at five years’ follow-up
were greater for fixed-bearing TKRs in older patients (>
70 years),
and greater for mobile-bearing TKRs in younger patients (≤ 70 years).
These findings should be confirmed by an extended age controlled
study, as the ideal choice of prosthesis might depend on the age
of the patient at the time of surgery.
We investigated the role of ion release in the assessment of fixation of the implant after total knee replacement and hypothesised that ion monitoring could be a useful parameter in the diagnosis of prosthetic loosening. We enrolled 59 patients with unilateral procedures and measured their serum aluminium, titanium, chromium and cobalt ion levels, blinded to the clinical and radiological outcome which was considered to be the reference standard. The cut-off levels for detection of the ions were obtained by measuring the levels in 41 healthy blood donors who had no implants. Based on the clinical and radiological evaluation the patients were divided into two groups with either stable (n = 24) or loosened (n = 35) implants. A significant increase in the mean level of Cr ions was seen in the group with failed implants (p = 0.001). The diagnostic accuracy was 71% providing strong evidence of failure when the level of Cr ions exceeded the cut-off value. The possibility of distinguishing loosening from other causes of failure was demonstrated by the higher diagnostic accuracy of 83%, when considering only patients with failure attributable to loosening. Measurement of the serum level of Cr ions may be of value for detecting failure due to loosening when the diagnosis is in doubt. The other metal ions studies did not have any diagnostic value.
We describe 119 meniscal allograft transplantations performed concurrently with articular cartilage repair in 115 patients with severe articular cartilage damage. In all, 53 (46.1%) of the patients were over the age of 50 at the time of surgery. The mean follow-up was for 5.8 years (2 months to 12.3 years), with 25 procedures (20.1%) failing at a mean of 4.6 years (2 months to 10.4 years). Of these, 18 progressed to knee replacement at a mean of 5.1 years (1.3 to 10.4). The Kaplan-Meier estimated mean survival time for the whole series was 9.9 years ( The survival of the transplant was not affected by gender, the severity of cartilage damage, axial alignment, the degree of narrowing of the joint space or medial
The Q angle is an important determinant of patellar tracking, though its clinical relevance is debatable. One controversy centres around any possible differences in its value between men and women. The accepted, though unproven explanation, for the greater Q angle in women is that a woman has a wider pelvis. However, because of the long distance between the pelvis and patella, relative to the distance from the patella to the tibial tuberosity, large changes in the position of the anterior superior iliac spine are necessary to effect significant changes in the Q angle. In our study of 69 subjects, we did not find such large differences in the position of the anterior superior iliac spine, and found a mean difference of only 2.3° between the Q angles of men and women. Furthermore, we found that men and women of equal height demonstrated similar Q angles, with taller people having slightly smaller Q angles. The slight difference in Q angles between men and women can be explained by the fact that men tend to be taller.