The continual cycle of bone formation and resorption
is carried out by osteoblasts, osteocytes, and osteoclasts under
the direction of the bone-signaling pathway. In certain situations
the host cycle of bone repair is insufficient and requires the assistance
of
Matrix-induced autologous chondrocyte implantation
(MACI) is an established technique used to treat osteochondral lesions
in the knee. For larger osteochondral lesions (>
5 cm2)
deeper than approximately 8 mm we have combined the use of two MACI
membranes with impaction grafting of the subchondral bone. We report
our results of 14 patients who underwent the ‘bilayer collagen membrane’
technique (BCMT) with a mean follow-up of 5.2 years (2 to 8). There
were 12 men and two women with a mean age of 23.6 years (16 to 40).
The mean size of the defect was 7.2 cm2 (5.2 to 12 cm2)
and were located on the medial (ten) or lateral (four) femoral condyles.
The mean modified Cincinnati knee score improved from 45.1 (22 to
70) pre-operatively to 82.8 (34 to 98) at the most recent review
(p <
0.05). The visual analogue pain score improved from 7.3
(4 to 10) to 1.7 (0 to 6) (p <
0.05). Twelve patients were considered
to have a good or excellent clinical outcome. One graft failed at
six years. The BCMT resulted in excellent functional results and durable
repair of large and deep osteochondral lesions without a high incidence
of graft-related complications.
Aims. The purpose of this study was to assess the success rate and functional outcomes of
Aims. This study aims to report the outcomes in the treatment of unstable proximal third scaphoid nonunions with arthroscopic curettage, non-vascularized
Aims. Large acetabular bone defects encountered in revision total hip arthroplasty (THA) are challenging to restore. Metal constructs for structural support are combined with
Aims. A variety of surgical methods and strategies have been demonstrated for Andersson lesion (AL) therapy. In 2011, we proposed and identified the feasibility of stabilizing the spine without curettaging the vertebral or discovertebral lesion to cure non-kyphotic AL. Additionally, due to the excellent reunion ability of ankylosing spondylitis, we further came up with minimally invasive spinal surgery (MIS) to avoid the need for both
Aims. The purpose of this systematic review was to determine the rates of union for vascularized versus non-vascularized grafting techniques in the operative management of scaphoid nonunion. Secondary aims were to determine the effect of the fixation techniques used, the source of grafting, as well as the influence of fracture location (proximal pole) and avascular necrosis (AVN). Methods. A search of PubMed, MEDLINE, and Embase was performed in June 2021 using the Preferred Reporting Items for Systematic Review and Meta-Analyses statement and registered using the PROSPERO International prospective register of systematic reviews. The primary outcome was union rate. Results. There were 78 studies that met the inclusion criteria with a total of 7,671 patients (87.8% male, 12.2% female). The mean age was 27.9 years (SD 3.8) and the mean follow-up was 30.9 months (SD 25.9). The mean union rate was 88.7% (95% confidence interval (CI) 85.0 to 92.5) for non-vascularized grafts versus 87.5% (95% CI 82.8 to 92.2) for vascularized grafts (p = 0.685). Pooled analysis of trial data alone found a mean union rate of 82.4% (95% CI 66.9% to 97.9%) for non-vascularized grafts and 89.4% (95% CI 84.1% to 94.7%) for vascularized grafts (p = 0.780). No significant difference was observed in union rates between any of the fixation techniques used in the studies (p = 0.502). Distal radius and iliac crest graft source had comparable mean union rates (86.9% (95% CI 83.1 to 90.7) vs 87.6% (95% CI 82.2 to 92.9); p = 0.841). Studies that excluded patients with both proximal pole fractures and AVN (n = 14) had a mean union rate of 96.5% (95% CI 94.2 to 98.9) that was significantly greater than the mean union rate of 86.8% (95% CI 83.2 to 90.4) observed in the remaining studies (p < 0.001). Conclusion. Current evidence suggests vascularized
Aims. Our objective was to conduct a systematic review and meta-analysis, to establish whether differences arise in clinical outcomes between autologous and synthetic
Aims. Bone stock restoration of acetabular bone defects using impaction
Aims. The aim of this study is to report the long-term outcomes of instrumented femoral revisions with impaction allograft
Nonunion of the tibia associated with bone loss, previous infection, obliteration of the intramedullary canal or located in the distal metaphysis poses a challenge to the surgeon and significant morbidity to patients. We retrospectively reviewed the records of 24 patients who were treated by central
Aims. Femoral impaction
Our aim was to evaluate the results of triple arthrodesis, performed without the use of supplementary
We reviewed 59
We evaluated the maturation of
We report the use of a free vascularised iliac
Proximal humeral fractures are the third most common fracture among the elderly. Complications associated with fixation include screw perforation, varus collapse, and avascular necrosis of the humeral head. To address these challenges, various augmentation techniques to increase medial column support have been developed. There are currently no recent studies that definitively establish the superiority of augmented fixation over non-augmented implants in the surgical treatment of proximal humeral fractures. The aim of this systematic review and meta-analysis was to compare the outcomes of patients who underwent locking-plate fixation with cement augmentation or bone-graft augmentation versus those who underwent locking-plate fixation without augmentation for proximal humeral fractures. The search was carried out according to the Preferred Reporting Items for Systematic Reviews and Meta-analyses guidelines. Articles involving patients with complex proximal humeral fractures treated using open reduction with locking-plate fixation, with or without augmentation, were considered. A meta-analysis of comparative studies comparing locking-plate fixation with cement augmentation or with bone-graft augmentation versus locking-plate fixation without augmentation was performed.Aims
Methods
We developed a method of applying vibration to the impaction
Aims. The aim of this study was to evaluate the efficacy of the surgical dislocation approach and modified trapdoor procedure for the treatment of chondroblastoma of the femoral head. Patients and Methods. A total of 17 patients (ten boys, seven girls; mean age 16.4 years (11 to 26)) diagnosed with chondroblastoma of the femoral head who underwent surgical dislocation of the hip joint, modified trapdoor procedure, curettage, and
Clinical experience of impaction
Ununited fractures of the scaphoid with extensive bone resorption are usually treated by
Impaction allograft is an established method of securing initial stability of an implant in arthroplasty. Subsequent bone integration can be prolonged, and the volume of allograft may not be maintained. Intermittent administration of parathyroid hormone has an anabolic effect on bone and may therefore improve integration of an implant. Using a canine implant model we tested the hypothesis that administration of parathyroid hormone may improve osseointegration of implants surrounded by
The increasing need for total hip replacement
(THR) in an ageing population will inevitably generate a larger number
of revision procedures. The difficulties encountered in dealing
with the bone deficient acetabulum are amongst the greatest challenges
in hip surgery. The failed acetabular component requires reconstruction
to restore the hip centre and improve joint biomechanics. Impaction
bone grafting is successful in achieving acetabular reconstruction
using both cemented and cementless techniques.
Loss of bone stock is a major problem in revision surgery of the hip. Impaction
Objectives. Deep bone and joint infections (DBJI) are directly intertwined with health, demographic change towards an elderly population, and wellbeing. The elderly human population is more prone to acquire infections, and the consequences such as pain, reduced quality of life, morbidity, absence from work and premature retirement due to disability place significant burdens on already strained healthcare systems and societal budgets. DBJIs are less responsive to systemic antibiotics because of poor vascular perfusion in necrotic bone, large bone defects and persistent biofilm-based infection. Emerging bacterial resistance poses a major threat and new innovative treatment modalities are urgently needed to curb its current trajectory. Materials and Methods. We present a new biphasic ceramic bone substitute consisting of hydroxyapatite and calcium sulphate for local antibiotic delivery in combination with bone regeneration. Gentamicin release was measured in four setups: 1) in vitro elution in Ringer’s solution; 2) local elution in patients treated for trochanteric hip fractures or uncemented hip revisions; 3) local elution in patients treated with a bone tumour resection; and 4) local elution in patients treated surgically for chronic corticomedullary osteomyelitis. Results. The release pattern in vitro was comparable with the obtained release in the patient studies. No recurrence was detected in the osteomyelitis group at latest follow-up (minimum 1.5 years). Conclusions. This new biphasic bone substitute containing antibiotics provides safe prevention of bone infections in a range of clinical situations. The in vitro test method predicts the in vivo performance and makes it a reliable tool in the development of future antibiotic-eluting bone-regenerating materials. Cite this article: M. Stravinskas, P. Horstmann, J. Ferguson, W. Hettwer, M. Nilsson, S. Tarasevicius, M. M. Petersen, M. A. McNally, L. Lidgren. Pharmacokinetics of gentamicin eluted from a regenerating
Autologous chondrocyte implantation (ACI) is a technique used for the treatment of symptomatic osteochondral defects of the knee. A variation of the original periosteum membrane technique is the matrix-induced autologous chondrocyte implantation (MACI) technique. The MACI membrane consists of a porcine type-I/III collagen bilayer seeded with chondrocytes. Osteochondral defects deeper than 8 to 10 mm usually require
Aims. The aim of this study was to analyze the effect of a lateral rim mesh on the survival of primary total hip arthroplasty (THA) in young patients, aged 50 years or younger. Patients and Methods. We compared a study group of 235 patients (257 hips) who received a primary THA with the use of impaction
We identified 1305 femoral impaction
We determined the efficacy of a devitalised autograft
(n = 13) and allograft (n = 16) cortical strut
Malunion is the most common complication of the
distal radius with many modalities of treatment available for such
a problem. The use of
The use of autograft bone is the best option
when undertaking a procedure that requires
The role of bone-graft extenders in impaction revision surgery is becoming increasingly important. Tricalcium phosphate and hydroxyapatite have been shown to be both biocompatible and osteoconductive, yet many surgeons remain reluctant to use them. The difficulty in handling bone-graft extenders can be partly alleviated by using porous particles and adding clotted blood. In an in vitro model we measured the cohesive properties of various impaction graft mixes. Several factors were evaluated including the use of pure
The complications of impaction
We evaluated the long-term results of 116 total hip replacements with a superolateral shelfplasty in 102 patients with osteoarthritis secondary to developmental dysplasia of the hip. After a mean follow-up of 19.5 years (11.5 to 26.0), 14 acetabular components (12%) had been revised. The cumulative survival at 20 years was 78%, with revision for loosening of the acetabular component as the end-point. All grafts were well integrated and showed remodelling. In six grafts some resorption had occurred under the heads of the screws where the graft was not supporting the socket. Apart from these 14 revisions, seven acetabular components had possible radiological signs of loosening at a mean follow-up of 14.5 years, one had signs of probable loosening, and five had signs of definite loosening. These results indicate that this technique of
We describe our experience with vascularised
Objectives. Osteophytes are products of active endochondral and intramembranous ossification, and therefore could theoretically provide significant efficacy as
The conventional treatment of comminuted fractures in the distal radius has been unsatisfactory. We therefore made a prospective study using the principle of ligamentotoxis and primary cancellous
There is a high risk of the development of avascular
necrosis of the femoral head and nonunion after the treatment of
displaced subcapital fractures of the femoral neck in patients aged
<
50 years. We retrospectively analysed the results following
fixation with two cannulated compression screws and a vascularised
iliac
During revision total hip replacement using morcellised compacted bone allograft, 16 patients were randomised to receive a graft which had been rinsed in either an ibandronate solution or in saline. Patients were assessed by dual energy x-ray absorptiometry after operation and at 3, 6, 12 and 24 months. A region of interest between the tip of the femoral stem and the distal plastic plug was chosen to measure the changes in bone density over time. The study was double-blinded. In all the control patients the bone density decreased during the first three months and then remained constant at this lower level. A large proportion of the mass of the
We report the clinical and radiographic outcomes
of 208 consecutive femoral revision arthroplasties performed in 202
patients (119 women, 83 men) between March 1991 and December 2007
using the X-change Femoral Revision System, fresh-frozen morcellised
allograft and a cemented polished Exeter stem. All patients were
followed prospectively. The mean age of the patients at revision
was 65 years (30 to 86). At final review in December 2013 a total
of 130 patients with 135 reconstructions (64.9%) were alive and
had a non re-revised femoral component after a mean follow-up of
10.6 years (4.7 to 20.9). One patient was lost to follow-up at six
years, and their data were included up to this point.
Re-operation for any reason was performed in 33 hips (15.9%), in
13 of which the femoral component was re-revised (6.3%). The mean
pre-operative Harris hip score was 52 (19 to 95) (n = 73) and improved
to 80 (22 to 100) (n = 161) by the last follow-up. Kaplan–Meier
survival with femoral re-revision for any reason as the endpoint
was 94.9% (95% confidence intervals (CI) 90.2 to 97.4) at ten years;
with femoral re-revision for aseptic loosening as the endpoint it was
99.4% (95% CI 95.7 to 99.9); with femoral re-operation for any reason
as the endpoint it was 84.5% (95% CI 78.3 to 89.1); and with subsidence ≥ 5
mm it was 87.3% (95% CI 80.5 to 91.8). Femoral revision with the
use of impaction allograft
In children, nonunion of fractures of the waist of the scaphoid is uncommon. Treatment has included
The clinical and radiological results of 50 consecutive acetabular reconstructions in 48 patients using impaction grafting have been retrospectively reviewed. A 1:1 mixture of frozen, ground irradiated
Revascularisation of syngeneic and allogeneic intramuscular
We present an update of the clinical and radiological results of 62 consecutive acetabular revisions using impacted morsellised cancellous
We hypothesised that cells obtained via a Reamer–Irrigator–Aspirator
(RIA) system retain substantial osteogenic potential and are at
least equivalent to graft harvested from the iliac crest. Graft
was harvested using the RIA in 25 patients (mean age 37.6 years
(18 to 68)) and from the iliac crest in 21 patients (mean age 44.6
years (24 to 78)), after which ≥ 1 g of bony particulate graft material
was processed from each. Initial cell viability was assessed using Trypan
blue exclusion, and initial fluorescence-activated cell sorting
(FACS) analysis for cell lineage was performed. After culturing
the cells, repeat FACS analysis for cell lineage was performed and
enzyme-linked immunosorbent assay (ELISA) for osteocalcin, and Alizarin
red staining to determine osteogenic potential. Cells obtained via
RIA or from the iliac crest were viable and matured into mesenchymal
stem cells, as shown by staining for the specific mesenchymal antigens
CD90 and CD105. For samples from both RIA and the iliac crest there
was a statistically significant increase in bone production (both
p <
0.001), as demonstrated by osteocalcin production after induction. . Medullary autograft cells harvested using RIA are viable and
osteogenic. Cell viability and osteogenic potential were similar
between
1. Sixteen cases of thenar paralysis are reviewed in which a
This study identified variables which influence the outcome of surgical management on 126 ununited scaphoid fractures managed by internal fixation and non-vascular
Seventy-nine open tibial fractures were treated with unilateral uniplanar tubular external fixators. Excellent stability allowed early weight-bearing. All comminuted fractures, with or without bone loss, and some transverse or short oblique fractures with intermediate fragments were treated by early
We have reviewed the results of 30 operations performed on 23 patients with Ficat stage-III or stage-IV osteonecrosis of the femoral head in which autogenous cortical and cancellous
We have reviewed retrospectively 68 revisions of the femoral component in arthroplasties of the hip in 65 patients, using impaction
Delayed union or non-union of the scaphoid was treated by a
We describe a new method of reconstruction after resection of tumours of the proximal tibia by grafting and arthrodesis of the knee. Two separate vascularised
Between June 1991 and May 1996 we carried out arthrodesis on 15 patients with flail or partially flail wrists using an AO/ASIF dynamic compression plate (DCP) without a
Dysplastic acetabula were augmented during total hip replacement by superolateral autografts. In cases of primary arthroplasty these were taken from the excised femoral head and in revision surgery from the iliac crest. Two or (usually) three small grafts were used to facilitate revascularisation; they were fixed with lag screws to the roughened iliac bone above the acetabulum. We reviewed 84 hips (63 primary arthroplasties and 21 revisions) more than five years (mean 10.1) after operation. All but one of the grafts showed consolidation within three months and they had become structurally integrated with the iliac bone, as evidenced by the trabecular reorientation. Resorption, which has caused early socket failure when large
Sixty-one patients with 68 osteonecrotic femoral heads, at different stages of development, were treated surgically; their average age was 36 years. Necrosis followed a fracture in 43 hips and traumatic dislocation in three. It was idiopathic in 14, cortisone-induced in seven and associated with gout in one. The operation of multiple drilling, curettage of the necrotic bone and muscle pedicle
This single-centre observational study aimed to describe the results of extensive bone impaction grafting of the whole acetabular cavity in combination with an uncemented component in acetabular revisions performed in a standardized manner since 1993. Between 1993 and 2013, 370 patients with a median age of 72 years (interquartile range (IQR) 63 to 79 years) underwent acetabular revision surgery. Of these, 229 were more than ten years following surgery and 137 were more than 15 years. All revisions were performed with extensive use of morcellized allograft firmly impacted into the entire acetabular cavity, followed by insertion of an uncemented component with supplementary screw fixation. All types of reoperation were captured using review of radiographs and medical charts, combined with data from the local surgical register and the Swedish Hip Arthroplasty Register.Aims
Methods
We describe a new technique for open reduction,
Fifty-six patients with ununited intracapsular fractures of the femoral neck were treated by internal fixation and muscle-pedicle
In fully-grown mongrel dogs, diaphyseal ulnar defects 25 mm long were stabilised by screws and plates, and were temporarily filled with silicone rubber blocks. After eight weeks the block was replaced either by fresh autogeneic cancellous bone, allogeneic deep-frozen cancellous bone, allogeneic decalcified bone matrix, or bone matrix gelatin. After 24 weeks the implants were evaluated by radiography, histology, and measurements of new bone volume, using computer-assisted density registration on microradiographs. Only the autogeneic
Segmental collapse occurs in the early stage of a vascular necrosis (AVN) of the femoral head, and is associated with a poor prognosis. Since it develops at a relatively young age, the long-term outcome after total hip replacement is a major concern. We have compared the long-term results of pedicle
In revision total hip replacement, bone loss can be managed by impacting porous bone chips. In order to guarantee sufficient mechanical strength, the bone chips have to be compacted. The aim of this study was to determine in an We found that the pneumatic method reached higher values of impaction hardness, contact stiffness and bulk density suggesting an increase in stability of the implant. No significant differences were found between the two different methods concerning the penetration resistance. The pneumatic method might reduce the risk of fracture
We performed curettage and
The use of impacted, morsellised
Total hip replacement has been very successful in patients with painful, stiff hips associated with protrusio acetabuli, but the heat of polymerisation of methylmethacrylate cement may cause necrosis of the thin medial wall with consequent danger of migration of the cup. Since 1968 at Wrightington, thin slices of the head of the femur have been used as
Aims
Patients and Methods
The properties of impacted morsellised
We treated three patients with malunion after comminuted intercondylar fractures of the humerus by intra-articular derotational opening-wedge osteotomy and the insertion of a tricortical iliac
Twenty-nine patients with avascular necrosis of the femoral head after injury have been treated by operation. Multiple drilling of the femoral head was performed, necrotic bone removed and a muscle-pedicle
A cortical
Aims
Patients and Methods
It has been shown in experimental animals that the living cells in a bone autograft can make an important contribution to osteogenesis. However, some common clinical techniques, such as the topical use of antibiotic powders on grafts or on the graft bed, are likely to damage or kill the cells. In this experimental study in rats, bone isografts dusted with chloramphenicol or methicillin powder or with Polybactrin spray before subcutaneous implantation produced little or no new bone over a period of two weeks whereas untreated, control grafts showed abundant osteogenesis, as did grafts pretreated with solutions of antibiotics. The effect of short-term storage of the grafts for 3 to 24 hours in air, saline or culture medium before implantation was also examined. Grafts stored in culture medium generally did as well as, or better than, fresh control grafts whereas immersion in saline inhibited osteogenesis. The importance of these results for clinical
We investigated the antibiotic concentration in fresh-frozen femoral head allografts harvested from two groups of living donors. Ten samples were collected from patients with osteoarthritis of the hip and ten from those with a fracture of the neck of the femur scheduled for primary arthroplasty. Cefazolin (1 g) was administered as a pre-operative prophylactic antibiotic. After storage at −80°C for two weeks the pattern of release of cefazolin from morsellised femoral heads was evaluated by an We concluded that allografts of morsellised bone from the femoral head harvested from patients undergoing arthroplasty of the hip contained cefazolin, which had been administered pre-operatively and they exhibited inhibitory effects against bacteria
In patients who underwent autogenous iliac
Large osteochondral lesions (OCLs) of the shoulder
of the talus cannot always be treated by traditional osteochondral
autograft techniques because of their size, articular geometry and
loss of an articular buttress. We hypothesised that they could be
treated by transplantation of a vascularised corticoperiosteal graft
from the ipsilateral medial femoral condyle. Between 2004 and 2011, we carried out a prospective study of
a consecutive series of 14 patients (five women, nine men; mean
age 34.8 years, 20 to 54) who were treated for an OCL with a vascularised
bone graft. Clinical outcome was assessed using a visual analogue
scale (VAS) for pain and the American Orthopaedic Foot and Ankle Society
(AOFAS) hindfoot score. Radiological follow-up used plain radiographs
and CT scans to assess graft incorporation and joint deterioration. At a mean follow-up of 4.1 years (2 to 7), the mean VAS for pain
had decreased from 5.8 (5 to 8) to 1.8 (0 to 4) (p = 0.001) and
the mean AOFAS hindfoot score had increased from 65 (41 to 70) to
81 (54 to 92) (p = 0.003). Radiologically, the talar contour had
been successfully reconstructed with stable incorporation of the
vascularised corticoperiosteal graft in all patients. Joint degeneration
was only seen in one ankle. Treatment of a large OCL of the shoulder of the talus with a
vascularised corticoperiosteal graft taken from the medial condyle
of the femur was found to be a safe, reliable method of restoring
the contour of the talus in the early to mid-term. Cite this article:
Failure of total hip arthroplasty with acetabular deficiency occurred in 55 patients (60 hips) and was treated with acetabular revision using morsellised allograft and a cemented metal-backed component. A total of 50 patients (55 hips) were available for clinical and radiological evaluation at a mean follow-up of 5.8 years (3 to 9.5). No hip required further revision of the acetabular component because of aseptic loosening. All the hips except one had complete incorporation of the allograft demonstrated on the radiographs. A complete radiolucent line of >
1 mm was noted in two hips post-operatively. A good to excellent result occurred in 50 hips (91%). With radiological evidence of aseptic loosening of the acetabular component as the end-point, the survivorship at a mean of 5.8 years after surgery was 96.4%. The use of impacted allograft chips in combination with a cemented metal-backed acetabular component and screw fixation can achieve good medium-term results in patients with acetabular bone deficiency.
The primary aim of this study was to determine the morbidity
of a tibial strut autograft and characterize the rate of bony union
following its use. We retrospectively assessed a series of 104 patients from a single
centre who were treated with a tibial strut autograft of > 5 cm
in length. A total of 30 had a segmental reconstruction with continuity
of bone, 27 had a segmental reconstruction without continuity of
bone, 29 had an arthrodesis and 18 had a nonunion. Donor-site morbidity
was defined as any event that required a modification of the postoperative
management. Union was assessed clinically and radiologically at
a median of 36 months (IQR, 14 to 74).Aims
Patients and Methods
Using the United States Nationwide Inpatient
Sample, we identified national trends in revision spinal fusion
along with a comprehensive comparison of comorbidities, inpatient
complications and surgical factors of revision spinal fusion compared
to primary spinal fusion. In 2009, there were 410 158 primary spinal fusion discharges
and 22 128 revision spinal fusion discharges. Between 2002 and 2009,
primary fusion increased at a higher rate compared with revision
fusion (56.4% In the multivariable logistic regression model for all spinal
fusions, depression (odds ratio (OR) 1.53, p <
0.001), psychotic
disorders (OR 1.49, p <
0.001), deficiency anaemias (OR 1.35,
p <
0.001) and smoking (OR 1.10, p = 0.006) had a greater chance
of occurrence in revision spinal fusion discharges than in primary
fusion discharges, adjusting for other variables. In terms of complications,
after adjusting for all significant comorbidities, this study found
that dural tears (OR 1.41; p <
0.001) and surgical site infections
(OR 3.40; p <
0.001) had a greater chance of occurrence in revision
spinal fusion discharges than in primary fusion discharges (p <
0.001). A p-value <
0.01 was considered significant in all final
analyses. Cite this article:
The purpose of this prospective study was to
evaluate the long-term clinical and radiological outcomes of revision of
the femoral component of a total hip replacement using impaction
bone grafting. Femoral revision with an impacted allograft was performed
on 29 patients (31 hips). In all, 21 hips (68%) had grade III or
IV femoral defects according to the Endo-Klinik classification.
A total of 11 patients (12 hips) died before the ten-year follow-up
period. Of the remaining patients, 18 patients (19 hips) were followed
for 10 to 15 years; three further patients died during this time.
None of the 31 stems underwent further revision of their stem. However,
four stems showed extensive subsidence (>
15 mm). One of these patients
had a femoral fracture that required fixation. Three other patients
had a femoral fracture, two of which required fixation and the other
was treated conservatively. Patients with a femoral fracture and/or
severe subsidence had significantly more grade IV defects (six of
seven hips; p = 0.004). One patient needed a closed reduction for
dislocation. Impaction allografting in revision hip surgery gives good long-term
results for femora with grades I, II and III Endo-Klinik-classified
defects. Extensive subsidence and femoral fractures were seen mainly
in patients with grade IV damaged femora.
In impaction grafting of contained bone defects after revision joint arthroplasty the graft behaves as a friable aggregate and its resistance to complex forces depends on grading, normal load and compaction. Bone mills in current use produce a distribution of particle sizes more uniform than is desirable for maximising resistance to shear stresses. We have performed experiments in vitro using morsellised allograft bone from the femoral head which have shown that its mechanical properties improve with increasing normal load and with increasing shear strains (strain hardening). The mechanical strength also increases with increasing compaction energy, and with the addition of bioglass particles to make good the deficiency in small and very small fragments. Donor femoral heads may be milled while frozen without affecting the profile of the particle size. Osteoporotic femoral heads provide a similar grading of sizes, although fewer particles are obtained from each specimen. Our findings have implications for current practice and for the future development of materials and techniques.
A high percentage of hips in patients with rheumatoid arthritis presenting for total joint replacement have protrusio deformity with extremely thin medial acetabular walls. Biomechanical principles suggest that, to prevent inward migration of the acetabular component, the prosthesis should be positioned laterally near the acetabular rim. To reinforce the medial wall, the femoral head is fashioned into a solid graft which is anchored against the medial wall as a plug, minimising the amount of cement used and making the use of wire mesh and restraining rings about the acetabulum unnecessary. A series of nine operations on seven patients is presented. Serial radiographs, tomograms and scintigrams taken after operation suggest satisfactory incorporation of the grafts, and no complications have been encountered in a follow-up period ranging from three months to two years.
A clinical investigation into a new bone void filler is giving
first data on systemic and local exposure to the anti-infective
substance after implantation. A total of 20 patients with post-traumatic/post-operative bone
infections were enrolled in this open-label, prospective study.
After radical surgical debridement, the bone cavity was filled with
this material. The 21-day hospitalisation phase included determination
of gentamicin concentrations in plasma, urine and wound exudate, assessment
of wound healing, infection parameters, implant resorption, laboratory
parameters, and adverse event monitoring. The follow-up period was
six months. Objective
Method
The osteoinductive properties of demineralised
bone matrix have been demonstrated in animal studies. However, its therapeutic
efficacy has yet to be proven in humans. The clinical properties
of AlloMatrix, an injectable calcium-based demineralised bone matrix
allograft, were studied in a prospective randomised study of 50
patients with an isolated unstable distal radial fracture treated
by reduction and Kirschner (K-) wire fixation. A total of 24 patients
were randomised to the graft group (13 men and 11 women, mean age
42.3 years (20 to 62)) and 26 to the no graft group (8 men and 18
women, mean age 45.0 years (17 to 69)). At one, three, six and nine weeks, and six and 12 months post-operatively,
patients underwent radiological evaluation, assessments for range
of movement, grip and pinch strength, and also completed the Disabilities
of Arm, Shoulder and Hand questionnaire. At one and six weeks and
one year post-operatively, bone mineral density evaluations of both
wrists were performed. No significant difference in wrist function and speed of recovery,
rate of union, complications or bone mineral density was found between
the two groups. The operating time was significantly higher in the
graft group (p = 0.004). Radiologically, the reduction parameters
remained similar in the two groups and all AlloMatrix extraosseous leakages
disappeared after nine weeks. This prospective randomised controlled trial did not demonstrate
a beneficial effect of AlloMatrix demineralised bone matrix in the
treatment of this category of distal radial fractures treated by
K-wire fixation. Cite this article:
We report the initial results of an ongoing randomised, prospective study on migration of the Exeter and Elite Plus femoral stems after impaction allografting, as measured by radiostereometry. Clinically, the impaction technique gave good results for both stems. The mean subsidence in the first year was 1.30 mm and 0.20 mm for the Exeter and the Elite Plus stems, respectively. In the second year, the Exeter stem continued to subside further by a mean of 0.42 mm, while the Elite Plus stem did not do so. Subsidence of the Exeter stem correlated with deficiency of bone stock as graded on the Gustilo and Pasternak scale. This correlation was not found for the Elite Plus stem. None of the other parameters which were studied predisposed to subsidence. There was no significant association between the amount of subsidence and the radiological appearance of the graft for either stem. Our findings do not support the theory that radial compression, due to subsidence of the Exeter stem, is the essential stimulus for remodelling in impaction allografting.
We report a long-term review of 60 acetabular components revised using impacted, morsellised bone allografts and a cemented polyethylene cup. The acetabular defects were cavitary (37) or combined (23). Follow-up was for a mean 11.8 years (10 to 15). Further revision was needed in five hips, two for septic and three for aseptic loosening. The overall survival rate at 11.8 years was 90%; excluding the septic cases it was 94%. Acetabular reconstruction with impacted morsellised cancellous grafts and cement gives satisfactory long-term results.
This study investigates the use of porous biphasic ceramics as graft extenders in impaction grafting of the femur during revision hip surgery. Impaction grafting of the femur was performed in four groups of sheep. Group one received pure allograft, group two 50% allograft and 50% BoneSave, group three 50% allograft and 50% BoneSave type 2 and group four 10% allograft and 90% BoneSave as the graft material. Function was assessed using an index of pre- and post-operative peak vertical ground reaction force ratios. Changes in bone mineral density were measured by dual energy X ray absorptiometry (DEXA) scanning. Loosening and subsidence were assessed radiographically and by histological examination of the explanted specimens. There was no statistically significant difference between the four groups after 18 months of unrestricted functional loading for all outcome measures.
This study presents the clinical and radiological results of 62 consecutive acetabular revisions in 58 patients, at a mean of 16.5 years follow-up (15 to 20). The Kaplan-Meier survivorship for the cup with end-point revisions for any reason, was 79% at 15 years (95% confidence interval (CI); 67 to 91). Excluding two revisions for septic loosening at three and six years, and one revision of a well-fixed cup after 12 years in the course of a femoral revision, the survivorship was 84% at 15 years (95% CI; 73 to 95). At review there were no additional cases of loosening, although seven acetabular reconstructions showed radiolucent lines in one or two zones. Acetabular revision using impacted large morsellised bone chips (0.7 cm to 1.0 cm) and a cemented cup, is a reliable technique of reconstruction, when assessed at more than 15 years.
A vascularised bone-graft procedure from the base of the second metacarpal was performed in 14 patients with nonunion of the scaphoid. There were 11 men and three women with a mean age of 22 years. In eight patients, who had dorsiflexed intercalated segment instability (DISI), an open wedge was formed at the site of nonunion, and the vascular pedicle was grafted from the volar side. In the six patients without DISI, transplantation was carried out through the same dorsal skin incision. Complete bony union was obtained in all patients after a mean post-operative period of 10.2 weeks, and DISI was corrected in all affected patients. According to Cooney’s clinical scoring system, the results were excellent in five, good in six, and fair in three patients. Because of its technical simplicity and the limited dissection needed, the procedure should be considered for the primary surgical treatment of patients with nonunion of the scaphoid.
The need for bone tissue supplementation exists in a wide range
of clinical conditions involving surgical reconstruction in limbs,
the spine and skull. The bone supplementation materials currently
used include autografts, allografts and inorganic matrix components;
but these pose potentially serious side-effects. In particular the
availability of the autografts is usually limited and their harvesting
causes surgical morbidity. Therefore for the purpose of supplementation
of autologous bone graft, we have developed a method for autologous
extracorporeal bone generation. Human osteoblast-like cells were seeded on porous granules of
tricalcium phosphate and incubated in osteogenic media while exposed
to mechanical stimulation by vibration in the infrasonic range of
frequencies. The generated tissue was examined microscopically following
haematoxylin eosin, trichrome and immunohistochemical staining.Objectives
Methods
Aims. Rates of reverse total shoulder arthroplasty (rTSA) continue to grow. Glenoid bone loss and deformity remains a technical challenge to the surgeon and may reduce improvements in patients’ outcomes. However, there is no consensus as to the optimal surgical technique to best reconstruct these patients’ anatomy. This review aims to compare the outcomes of glenoid bone grafting versus augmented glenoid prostheses in the management of glenoid bone loss in primary reverse total shoulder arthroplasty. Methods. This systematic review and meta-analysis evaluated study-level data in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement. We performed searches of Medline (Ovid), Embase (Ovid), and PubMed from their dates of inception to January 2022. From included studies, we analyzed data for preoperative and postoperative range of motion (ROM), patient-reported functional outcomes, and complication rates. Results. A total of 13 studies (919 shoulders) were included in the analysis. The mean age of patients at initial evaluation was 72.2 years (42 to 87), with a mean follow-up time of 40.7 months (24 to 120). Nine studies with 292 rTSAs evaluated the use of
Aims. The aim of this study was to investigate the incidence and characteristics of instrumentation failure (IF) after total en bloc spondylectomy (TES), and to analyze risk factors for IF. Methods. The medical records from 136 patients (65 male, 71 female) with a mean age of 52.7 years (14 to 80) who underwent TES were retrospectively reviewed. The mean follow-up period was 101 months (36 to 232). Analyzed factors included incidence of IF, age, sex, BMI, history of chemotherapy or radiotherapy, tumour histology (primary or metastasis; benign or malignant), surgical approach (posterior or combined), tumour location (thoracic or lumbar; junctional or non-junctional), number of resected vertebrae (single or multilevel), anterior resection line (disc-to-disc or intravertebra), type of
Aims. Giant cell tumour of bone (GCTB) is a locally aggressive lesion that is difficult to treat as salvaging the joint can be associated with a high rate of local recurrence (LR). We evaluated the risk factors for tumour relapse after treatment of a GCTB of the limbs. Methods. A total of 354 consecutive patients with a GCTB underwent joint salvage by curettage and reconstruction with
Aims. Congenital pseudarthrosis of the tibia (CPT) has traditionally been a difficult condition to treat, with high complication rates, including nonunion, refractures, malalignment, and leg length discrepancy. Surgical approaches to treatment of CPT include intramedullary rodding, external fixation, combined intramedullary rodding and external fixation, vascularized fibular graft, and most recently cross-union. The current study aims to compare the outcomes and complication rates of cross-union versus other surgical approaches as an index surgery for the management of CPT. Our hypothesis was that a good index surgery for CPT achieves union and minimizes complications such as refractures and limb length discrepancy. Methods. A multicentre study was conducted involving two institutions in Singapore and China. All patients with CPT who were surgically managed between January 2009 and December 2021 were included. The patients were divided based on their index surgery. Group 1 included patients who underwent excision of hamartoma, cross-union of the tibia and fibula, autogenic iliac
The October 2024 Foot & Ankle Roundup. 360. looks at: Hemiarthroplasty for hallux rigidus; Fixed or mobile-bearing ankle arthroplasty? A meta-analysis;
The October 2024 Spine Roundup. 360. looks at: Analysis of risk factors for non-fusion of
Aims. Various surgical techniques have been described for total hip arthroplasty (THA) in patients with Crowe type III dislocated hips, who have a large acetabular bone defect. The aim of this study was to evaluate the long-term clinical results of patients in whom anatomical reconstruction of the acetabulum was performed using a cemented acetabular component and autologous bone graft from the femoral neck. Methods. A total of 22 patients with Crowe type III dislocated hips underwent 28 THAs using