The primary aim of this study was to address the hypothesis that fracture morphology might be more important than posterior malleolar fragment size in rotational type posterior malleolar ankle fractures (PMAFs). The secondary aim was to identify clinically important predictors of outcome for each respective PMAF-type, to challenge the current dogma that surgical decision-making should be based on fragment size. This observational prospective cohort study included 70 patients with operatively treated rotational type PMAFs, respectively: 23 Haraguchi Type I (large posterolateral-oblique), 22 Type II (two-part posterolateral and posteromedial), and 25 (avulsion-) Type III. There was no standardized protocol on how to address the PMAFs and CT-imaging was used to classify fracture morphology and quality of postoperative syndesmotic reduction. Quantitative 3D-CT (Q3DCT) was used to assess the quality of fracture reduction, respectively: the proportion of articular involvement; residual intra-articular: gap, step-off, and 3D-displacement; and residual gap and step-off at the fibular notch. These predictors were correlated with the Foot and Ankle Outcome Score (FAOS) at two-years follow-up.Aims
Methods
To evaluate whether an ultra-low-dose CT protocol can diagnose
selected limb fractures as well as conventional CT (C-CT). We prospectively studied 40 consecutive patients with a limb
fracture in whom a CT scan was indicated. These were scanned using
an ultra-low-dose CT Reduced Effective Dose Using Computed Tomography
In Orthopaedic Injury (REDUCTION) protocol. Studies from 16 selected
cases were compared with 16 C-CT scans matched for age, gender and
type of fracture. Studies were assessed for diagnosis and image
quality. Descriptive and reliability statistics were calculated.
The total effective radiation dose for each scanned site was compared.Aims
Patients and Methods
In this randomized study, we aimed to compare quality of regenerate in monolateral Both groups were comparable in demographic and injury characteristics. A phantom (aluminium step wedge of increasing thickness) was designed to compare the density of regenerate on radiographs. A CT scan was performed at three and six months postoperatively to assess regenerate density. A total of 30 patients (29 male, one female; mean age 32.54 years (18 to 60)) with an infected nonunion of a tibial fracture presenting to our tertiary institute between June 2011 and April 2016 were included in the study.Aims
Patients and Methods
Although we often encounter patients with an aortic aneurysm
who also have diffuse idiopathic skeletal hyperostosis (DISH), there
are no reports to date of an association between these two conditions
and the pathogenesis of DISH remains unknown. This study therefore
evaluated the prevalence of DISH in patients with a thoracic aortic
aneurysm (AA). The medical records of 298 patients who underwent CT scans for
a diagnosis of an AA or following high-energy trauma were retrospectively
examined. A total of 204 patients underwent surgery for an AA and
94 had a high-energy injury and formed the non-AA group. The prevalence
of DISH was assessed on CT scans of the chest and abdomen and the
relationship between DISH and AA by comparison between the AA and
non-AA groups.Aims
Patients and Methods
The aim of this study was to analyse the effect of altered viewing
perspectives on the measurement of the glenopolar angle (GPA) and
the differences between these measurements made on 3D CT reconstructions
and anteroposterior (AP) scapular view radiographs. The influence of the viewing perspective on the GPA was assessed,
as were the differences in the measurements of the GPA between 3D
CT reconstructions and AP scapular view radiographs in 68 cadaveric
scapulae.Aims
Materials and Methods
Femoroacetabular impingement (FAI) has been highlighted and well
documented primarily in Western countries and there are few large
studies focused on FAI-related morphological assessment in Asian
patients. We chose to investigate this subject. We assessed the morphology of the hip and the prevalence of radiographic
FAI in Japanese patients by measuring predictors of FAI. We reviewed
a total of 1178 hips in 695 men and 483 women with a mean age of
58.2 years (20 to 89) using CT images that had been obtained for
reasons unrelated to symptoms from the hip. We measured the lateral
centre edge angle, acetabular index, crossover sign, alpha angle
and anterior femoral head-neck offset ratio.Aims
Patients and Methods
Patient-specific glenoid guides (PSGs) claim an improvement in
accuracy and reproducibility of the positioning of components in
total shoulder arthroplasty (TSA). The results have not yet been
confirmed in a prospective clinical trial. Our aim was to assess
whether the use of PSGs in patients with osteoarthritis of the shoulder
would allow accurate and reliable implantation of the glenoid component. A total of 17 patients (three men and 14 women) with a mean age
of 71 years (53 to 81) awaiting TSA were enrolled in the study.
Pre- and post-operative version and inclination of the glenoid were
measured on CT scans, using 3D planning automatic software. During
surgery, a congruent 3D-printed PSG was applied onto the glenoid
surface, thus determining the entry point and orientation of the
central guide wire used for reaming the glenoid and the introduction
of the component. Manual segmentation was performed on post-operative
CT scans to compare the planned and the actual position of the entry
point (mm) and orientation of the component (°).Aims
Patients and Methods
The clinical utility of routine cross sectional imaging of the
abdomen and pelvis in the screening and surveillance of patients
with primary soft-tissue sarcoma of the extremities for metastatic
disease is controversial, based on its questionable yield paired
with concerns regarding the risks of radiation exposure, cost, and
morbidity resulting from false positive findings. Through retrospective review of 140 patients of all ages (mean
53 years; 2 to 88) diagnosed with soft-tissue sarcoma of the extremity
with a mean follow-up of 33 months (0 to 291), we sought to determine
the overall incidence of isolated abdominopelvic metastases, their
temporal relationship to chest involvement, the rate of false positives, and
to identify disparate rates of metastases based on sarcoma subtype.Objectives
Methods
The objective of this study was to evaluate the rotation and
translation of each joint in the hindfoot and compare the load response
in healthy feet with that in stage II posterior tibial tendon dysfunction
(PTTD) flatfoot by analysing the reconstructive three-dimensional
(3D) computed tomography (CT) image data during simulated weight-bearing. CT scans of 15 healthy feet and 15 feet with stage II PTTD flatfoot
were taken first in a non-weight-bearing condition, followed by
a simulated full-body weight-bearing condition. The images of the
hindfoot bones were reconstructed into 3D models. The ‘twice registration’
method in three planes was used to calculate the position of the
talus relative to the calcaneus in the talocalcaneal joint, the
navicular relative to the talus in talonavicular joint, and the cuboid
relative to the calcaneus in the calcaneocuboid joint.Objective
Methods
We investigated the development of CT-based bony
radiological parameters associated with femoroacetabular impingement
(FAI) in a paediatric and adolescent population with no known orthopaedic
hip complaints. We retrospectively reformatted and reoriented
225 abdominal CTs into standardised CT pelvic images with neutral
pelvic tilt and inclination (244 female and 206 male hips) in patients
ranging from two to 19 years of age (mean 10.4 years). The Tönnis
angle, acetabular depth ratio, lateral centre–edge angle, acetabular
version and α-angle were assessed. Acetabular measurements demonstrated increased acetabular coverage
with age and/or progressive ossification of the acetabulum. The α-angle
decreased with age and/or progressive cortical bone development
and resultant narrowing of the femoral neck. Cam and pincer morphology
occurred as early as ten and 12 years of age, respectively, and
their prevalence in the adolescent patient population is similar
to that reported in the adult literature. Future aetiological studies
of FAI will need to focus on the early adolescent population. Cite this article:
This study aims to assess the correlation of CT-based structural
rigidity analysis with mechanically determined axial rigidity in
normal and metabolically diseased rat bone. A total of 30 rats were divided equally into normal, ovariectomized,
and partially nephrectomized groups. Cortical and trabecular bone
segments from each animal underwent micro-CT to assess their average
and minimum axial rigidities using structural rigidity analysis.
Following imaging, all specimens were subjected to uniaxial compression
and assessment of mechanically-derived axial rigidity.Objectives
Methods
Objectives.
Surgeons need to be able to measure angles and distances in three dimensions in the planning and assessment of knee replacement.
We studied the outcomes of hip and knee arthroplasties in a high-volume arthroplasty centre to determine if patients with morbid obesity (BMI ≥ 40 kg/m2) had unacceptably worse outcomes as compared to those with BMI < 40 kg/m2. In a two-year period, 4,711 patients had either total hip arthroplasty (THA; n = 2,370), total knee arthroplasty (TKA; n = 2,109), or unicompartmental knee arthroplasty (UKA; n = 232). Of these patients, 392 (8.3%) had morbid obesity. We compared duration of operation, anaesthetic time, length of stay (LOS), LOS > three days, out of hours attendance, emergency department attendance, readmission to hospital, return to theatre, and venous thromboembolism up to 90 days. Readmission for wound infection was recorded to one year. Oxford scores were recorded preoperatively and at one year postoperatively.Aims
Methods
The transition from shutdown of elective orthopaedic services to the resumption of pre-COVID-19 activity presents many challenges. These include concerns about patient safety, staff safety, and the viability of health economies. Careful planning is necessary to allow patients to benefit from orthopaedic care in a safe and sustainable manner. Cite this article:
Patient-specific (PS) implantation surgical technology has been introduced in recent years and a gradual increase in the associated number of surgical cases has been observed. PS technology uses a patient’s own geometry in designing a medical device to provide minimal bone resection with improvement in the prosthetic bone coverage. However, whether PS unicompartmental knee arthroplasty (UKA) provides a better biomechanical effect than standard off-the-shelf prostheses for UKA has not yet been determined, and still remains controversial in both biomechanical and clinical fields. Therefore, the aim of this study was to compare the biomechanical effect between PS and standard off-the-shelf prostheses for UKA. The contact stresses on the polyethylene (PE) insert, articular cartilage and lateral meniscus were evaluated in PS and standard off-the-shelf prostheses for UKA using a validated finite element model. Gait cycle loading was applied to evaluate the biomechanical effect in the PS and standard UKAs.Objectives
Methods