Clarke N Harcke H McHugh P Lee M Borns P MacEwen G

A technique of examining the infant hip joint with real-time ultrasound is described. Since the cartilaginous femoral head is clearly imaged by ultrasound, anatomical structures and their relationships can be accurately determined. Dislocated hips are easily detected and subluxations also can be visualized. We report our experience with 131 examinations in 104 patients, comprising 259 single hip studies. Of 83 patients who were previously untreated, there were 178 hip studies with three false-negative and four false-positive ultrasound results. No dislocations were missed. Twenty-seven patients who were already being treated were examined to assess hip location, comprising a total of 81 hip studies. In some cases the patients were examined while in an abduction device, cast, or Pavlik harness. In one case a dislocation was not detected. The method of examination using real-time ultrasound is considered to be reliable, accurate, and a useful adjunct to radiography. The advantages are that it is non-invasive, portable, and involves no exposure to radiation.