Advertisement for orthosearch.org.uk
Results 1 - 50 of 396
Results per page:
The Bone & Joint Journal
Vol. 96-B, Issue 1 | Pages 137 - 142
1 Jan 2014
Nayagam S Davis B Thevendran G Roche AJ

We describe the technique and results of medial submuscular plating of the femur in paediatric patients and discuss its indications and limitations. Specifically, the technique is used as part of a plate-after-lengthening strategy, where the period of external fixation is reduced and the plate introduced by avoiding direct contact with the lateral entry wounds of the external fixator pins. The technique emphasises that vastus medialis is interposed between the plate and the vascular structures. . A total of 16 patients (11 male and five female, mean age 9.6 years (5 to 17)), had medial submuscular plating of the femur. All underwent distraction osteogenesis of the femur with a mean lengthening of 4.99 cm (3.2 to 12) prior to plating. All patients achieved consolidation of the regenerate without deformity. The mean follow-up was 10.5 months (7 to 15) after plating for those with plates still in situ, and 16.3 months (1 to 39) for those who subsequently had their plates removed. None developed a deep infection. In two patients a proximal screw fractured without loss of alignment; one patient sustained a traumatic fracture six months after removal of the plate. . Placing the plate on the medial side is advantageous when the external fixator is present on the lateral side, and is biomechanically optimal in the presence of a femoral defect. We conclude that medial femoral submuscular plating is a useful technique for specific indications and can be performed safely with a prior understanding of the regional anatomy. Cite this article: Bone Joint J 2014;96-B:137–42


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 530 - 538
1 Apr 2020
Rollick NC Gadinsky NE Klinger CE Kubik JF Dyke JP Helfet DL Wellman DS

Aims. Dual plating of distal femoral fractures with medial and lateral implants has been performed to improve construct mechanics and alignment, in cases where isolated lateral plating would be insufficient. This may potentially compromise vascularity, paradoxically impairing healing. This study investigates effects of single versus dual plating on distal femoral vascularity. Methods. A total of eight cadaveric lower limb pairs were arbitrarily assigned to either 1) isolated lateral plating, or 2) lateral and medial plating of the distal femur, with four specimens per group. Contralateral limbs served as matched controls. Pre- and post-contrast MRI was performed to quantify signal intensity enhancement in the distal femur. Further evaluation of intraosseous vascularity was done with barium sulphate infusion with CT scan imaging. Specimens were then injected with latex medium and dissection was completed to assess extraosseous vasculature. Results. Quantitative MRI revealed a mean reduction of 21.2% (SD 1.3%) of arterial contribution in the lateral plating group and 25.4% (SD 3.2%) in the dual plating group (p = 0.051); representing a mean decrease in arterial contribution of 4.2%. The only significant difference found between both experimental groups was regionally, at the lateral aspect of the distal femur with a mean drop in arterial contribution in the lateral plating group of 18.9% (SD 2.6%) versus 24.0% (SD 3.2%) in the dual plating group (p = 0.048), representing a mean decrease in arterial contribution of 5.1%. Gross dissection revealed complete destruction of periosteal vessels underneath either medial or lateral plates in both groups. The network of genicular branches contributing to the posterior and distal femoral condyles was preserved in all specimens. A medial vascular pedicle was found dividing from the superficial femoral artery at a mean 12.7 cm (SD 1.7) proximal to the medial epicondyle and was undisrupted in the dual plating group. Conclusion. Lateral locking-plate application resulted in mean 21.2% reduction in distal femur vascularity. Addition of medial plates did not further markedly decrease vascularity. As such, the majority of the vascular insult occurred with lateral plating alone. Supplemental medially based fixation did not lead to marked devascularization of the distal femur, and should therefore be considered in the setting of comminution and poor bone stock in distal femoral fractures. Further clinical research is required to confirm the results of this study. Cite this article: Bone Joint J 2020;102-B(4):530–538


Bone & Joint Open
Vol. 2, Issue 8 | Pages 611 - 617
10 Aug 2021
Kubik JF Bornes TD Klinger CE Dyke JP Helfet DL

Aims. Surgical treatment of young femoral neck fractures often requires an open approach to achieve an anatomical reduction. The application of a calcar plate has recently been described to aid in femoral neck fracture reduction and to augment fixation. However, application of a plate may potentially compromise the regional vascularity of the femoral head and neck. The purpose of this study was to investigate the effect of calcar femoral neck plating on the vascularity of the femoral head and neck. Methods. A Hueter approach and capsulotomy were performed bilaterally in six cadaveric hips. In the experimental group, a one-third tubular plate was secured to the inferomedial femoral neck at 6:00 on the clockface. The contralateral hip served as a control with surgical approach and capsulotomy without fixation. Pre- and post-contrast MRI was then performed to quantify signal intensity in the femoral head and neck. Qualitative assessment of the terminal arterial branches to the femoral head, specifically the inferior retinacular artery (IRA), was also performed. Results. Quantitative MRI revealed a mean reduction of 1.8% (SD 3.1%) of arterial contribution in the femoral head and a mean reduction of 7.1% (SD 10.6%) in the femoral neck in the plating group compared to non-plated controls. Based on femoral head quadrant analysis, the largest mean decrease in arterial contribution was in the inferomedial quadrant (4.0%, SD 6.6%). No significant differences were found between control and experimental hips for any femoral neck or femoral head regions. The inferior retinaculum of Weitbrecht (containing the IRA) was directly visualized in six of 12 specimens. Qualitative MRI assessment confirmed IRA integrity in all specimens. Conclusion. Calcar femoral neck plating at the 6:00 position on the clockface resulted in minimal decrease in femoral head and neck vascularity, and therefore it may be considered as an adjunct to laterally-based fixation for reduction and fixation of femoral neck fractures, especially in younger patients. Cite this article: Bone Jt Open 2021;2(8):611–617


Bone & Joint Open
Vol. 5, Issue 2 | Pages 147 - 153
19 Feb 2024
Hazra S Saha N Mallick SK Saraf A Kumar S Ghosh S Chandra M

Aims. Posterior column plating through the single anterior approach reduces the morbidity in acetabular fractures that require stabilization of both the columns. The aim of this study is to assess the effectiveness of posterior column plating through the anterior intrapelvic approach (AIP) in the management of acetabular fractures. Methods. We retrospectively reviewed the data from R G Kar Medical College, Kolkata, India, from June 2018 to April 2023. Overall, there were 34 acetabulum fractures involving both columns managed by medial buttress plating of posterior column. The posterior column of the acetabular fracture was fixed through the AIP approach with buttress plate on medial surface of posterior column. Mean follow-up was 25 months (13 to 58). Accuracy of reduction and effectiveness of this technique were measured by assessing the Merle d’Aubigné score and Matta’s radiological grading at one year and at latest follow-up. Results. Immediate postoperative radiological Matta’s reduction accuracy showed anatomical reduction (0 to 1 mm) in 23 cases (67.6%), satisfactory (2 to 3 mm) in nine (26.4%), and unsatisfactory (> 3 mm) in two (6%). Merle d’Aubigné score at the end of one year was calculated to be excellent in 18 cases (52.9%), good in 11 (32.3%), fair in three (8.8%), and poor in two (5.9%). Matta’s radiological grading at the end of one year was calculated to be excellent in 16 cases (47%), good in nine (26.4%), six in fair (17.6%), and three in poor (8.8%). Merle d’Aubigné score at latest follow-up deteriorated by one point in some cases, but the grading remained the same; Matta’s radiological grading at latest follow-up also remained unchanged. Conclusion. Stabilization of posterior column through AIP by medial surface plate along the sciatic notch gives good stability to posterior column, and at the same time can avoid morbidity of the additional lateral window. Cite this article: Bone Jt Open 2024;5(2):147–153


Bone & Joint Open
Vol. 5, Issue 6 | Pages 489 - 498
12 Jun 2024
Kriechling P Bowley ALW Ross LA Moran M Scott CEH

Aims. The purpose of this study was to compare reoperation and revision rates of double plating (DP), single plating using a lateral locking plate (SP), or distal femoral arthroplasty (DFA) for the treatment of periprosthetic distal femur fractures (PDFFs). Methods. All patients with PDFF primarily treated with DP, SP, or DFA between 2008 and 2022 at a university teaching hospital were included in this retrospective cohort study. The primary outcome was revision surgery for failure following DP, SP, or DFA. Secondary outcome measures included any reoperation, length of hospital stay, and mortality. All basic demographic and relevant implant and injury details were collected. Radiological analysis included fracture classification and evaluation of metaphyseal and medial comminution. Results. A total of 111 PDFFs (111 patients, median age 82 years (interquartile range (IQR) 75 to 88), 86% female) with 32 (29%) Su classification 1, 37 (34%) Su 2, and 40 (37%) Su 3 fractures were included. The median follow-up was 2.5 years (IQR 1.2 to 5.0). DP, SP, and DFA were used in 15, 66, and 30 patients, respectively. Compared to SP, patients treated with DP were more likely to have metaphyseal comminution (47% vs 14%; p = 0.009), to be low fractures (47% vs 11%; p = 0.009), and to be anatomically reduced (100% vs 71%; p = 0.030). Patients selected for DFA displayed comparable amounts of medial/metaphyseal comminution as those who underwent DP. At a minimum follow-up of two years, revision surgery for failure was performed in 11 (9.9%) cases at a median of five months (IQR 2 to 9): 0 DP patients (0%), 9 SP (14%), and 2 DFA (6.7%) (p = 0.249). Conclusion. Using a strategy of DP fixation in fractures, where the fracture was low but there was enough distal bone to accommodate locking screws, and where there is metaphyseal comminution, resulted in equivalent survival free from revision or reoperation compared to DFA and SP fixation. Cite this article: Bone Jt Open 2024;5(6):489–498


The Bone & Joint Journal
Vol. 100-B, Issue 4 | Pages 468 - 474
1 Apr 2018
Kirzner N Zotov P Goldbloom D Curry H Bedi H

Aims. The aim of this retrospective study was to compare the functional and radiological outcomes of bridge plating, screw fixation, and a combination of both methods for the treatment of Lisfranc fracture dislocations. Patients and Methods. A total of 108 patients were treated for a Lisfranc fracture dislocation over a period of nine years. Of these, 38 underwent transarticular screw fixation, 45 dorsal bridge plating, and 25 a combination technique. Injuries were assessed preoperatively according to the Myerson classification system. The outcome measures included the American Orthopaedic Foot and Ankle Society (AOFAS) score, the validated Manchester Oxford Foot Questionnaire (MOXFQ) functional tool, and the radiological Wilppula classification of anatomical reduction. Results. Significantly better functional outcomes were seen in the bridge plate group. These patients had a mean AOFAS score of 82.5 points, compared with 71.0 for the screw group and 63.3 for the combination group (p < 0.001). Similarly, the mean Manchester Oxford Foot Questionnaire score was 25.6 points in the bridge plate group, 38.1 in the screw group, and 45.5 in the combination group (p < 0.001). Functional outcome was dependent on the quality of reduction (p < 0.001). A trend was noted which indicated that plate fixation is associated with a better anatomical reduction (p = 0.06). Myerson types A and C2 significantly predicted a poorer functional outcome, suggesting that total incongruity in either a homolateral or divergent pattern leads to worse outcomes. The greater the number of columns fixed the worse the outcome (p < 0.001). Conclusion. Patients treated with dorsal bridge plating have better functional and radiological outcomes than those treated with transarticular screws or a combination technique. Cite this article: Bone Joint J 2018;100-B:468–74


The Bone & Joint Journal
Vol. 96-B, Issue 3 | Pages 385 - 389
1 Mar 2014
Attal R Maestri V Doshi HK Onder U Smekal V Blauth M Schmoelz W

Using human cadaver specimens, we investigated the role of supplementary fibular plating in the treatment of distal tibial fractures using an intramedullary nail. Fibular plating is thought to improve stability in these situations, but has been reported to have increased soft-tissue complications and to impair union of the fracture. We proposed that multidirectional locking screws provide adequate stability, making additional fibular plating unnecessary. A distal tibiofibular osteotomy model performed on matched fresh-frozen lower limb specimens was stabilised with reamed nails using conventional biplanar distal locking (CDL) or multidirectional distal locking (MDL) options with and without fibular plating. Rotational stiffness was assessed under a constant axial force of 150 N and a superimposed torque of ± 5 Nm. Total movement, and neutral zone and fracture gap movement were analysed. In the CDL group, fibular plating improved stiffness at the tibial fracture site, albeit to a small degree (p = 0.013). In the MDL group additional fibular plating did not increase the stiffness. The MDL nail without fibular plating was significantly more stable than the CDL nail with an additional fibular plate (p = 0.008). These findings suggest that additional fibular plating does not improve stability if a multidirectional distal locking intramedullary nail is used, and is therefore unnecessary if not needed to aid reduction. Cite this article: Bone Joint J 2014;96-B:385–9


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 874 - 880
1 Jul 2020
Langerhuizen DWG Bergsma M Selles CA Jaarsma RL Goslings JC Schep NWL Doornberg JN

Aims. The aim of this study was to investigate whether intraoperative 3D fluoroscopic imaging outperforms dorsal tangential views in the detection of dorsal cortex screw penetration after volar plating of an intra-articular distal radial fracture, as identified on postoperative CT imaging. Methods. A total of 165 prospectively enrolled patients who underwent volar plating for an intra-articular distal radial fracture were retrospectively evaluated to study three intraoperative imaging protocols: 1) standard 2D fluoroscopic imaging with anteroposterior (AP) and elevated lateral images (n = 55); 2) 2D fluoroscopic imaging with AP, lateral, and dorsal tangential views images (n = 50); and 3) 3D fluoroscopy (n = 60). Multiplanar reconstructions of postoperative CT scans served as the reference standard. Results. In order to detect dorsal screw penetration, the sensitivity of dorsal tangential views was 39% with a negative predictive value (NPV) of 91% and an accuracy of 91%; compared with a sensitivity of 25% for 3D fluoroscopy with a NPV of 93% and an accuracy of 93%. On the postoperative CT scans, we found penetrating screws in: 1) 40% of patients in the 2D fluoroscopy group; 2) in 32% of those in the 2D fluoroscopy group with AP, lateral, and dorsal tangential views; and 3) in 25% of patients in the 3D fluoroscopy group. In all three groups, the second compartment was prone to penetration, while the postoperative incidence decreased when more advanced imaging was used. There were no penetrating screws in the third compartment (extensor pollicis longus groove) in the 3D fluoroscopy groups, and one in the dorsal tangential views group. Conclusion. Advanced intraoperative imaging helps to identify screws which have penetrated the dorsal compartments of the wrist. However, based on diagnostic performance characteristics, one cannot conclude that 3D fluoroscopy outperforms dorsal tangential views when used for this purpose. Dorsal tangential views are sufficiently accurate to detect dorsal screw penetration, and arguably more efficacious than 3D fluoroscopy. Cite this article: Bone Joint J 2020;102-B(7):874–880


Bone & Joint Research
Vol. 6, Issue 4 | Pages 204 - 207
1 Apr 2017
Fernandez MA Aquilina A Achten J Parsons N Costa ML Griffin XL

Objectives. The Sliding Hip Screw (SHS) is commonly used to treat trochanteric hip fractures. Fixation failure is a devastating complication requiring complex revision surgery. One mode of fixation failure is lag screw cut-out which is greatest in unstable fracture patterns and when the tip-apex distance of the lag screw is > 25 mm. The X-Bolt Dynamic Hip Plating System (X-Bolt Orthopaedics, Dublin, Ireland) is a new device which aims to reduce this risk of cut-out. However, some surgeons have reported difficulty minimising the tip-apex distance with subsequent concerns that this may lead to an increased risk of cut-out. Patients and Methods. We measured the tip-apex distance from the intra-operative radiographs of 93 unstable trochanteric hip fractures enrolled in a randomised controlled trial (Warwick Hip Trauma Evaluation, WHiTE One trial). Participants were treated with either the sliding hip screw or the X-Bolt dynamic hip plating system. We also recorded the incidence of cut-out in both groups, at a median follow-up time of 17 months. Results. There was a significantly increased tip-apex distance with the use of the X-Bolt (mean difference 3.7mm (95% confidence interval 1.58 to 5.73); SHS mean 17.1 mm, X-Bolt mean 20.8; p = 0.001. However, this was not associated with an increased incidence of cut-out at a median follow-up time of 17 months, with three cut-outs (6%) in the SHS group and 0 (0%) in the X-Bolt group. Conclusion. The X-Bolt is a safe implant with no increased risk for cut-out. Concerns about minimising the tip-apex distance may be justified but do not appear to be clinically important. Cite this article: M. A. Fernandez, A. Aquilina, J. Achten, N. Parsons, M. L. Costa, X. L. Griffin. The tip-apex distance in the X-Bolt dynamic plating system. Bone Joint Res 2017;6:–207. DOI: 10.1302/2046-3758.64.BJR-2015-0016.R2


The Bone & Joint Journal
Vol. 101-B, Issue 12 | Pages 1498 - 1505
1 Dec 2019
Sonntag J Woythal L Rasmussen P Branner U Hølmer P Jensen AK Lange KHW Brorson S

Aims. The aim of this study was to investigate the difference in functional outcome after repair and non-repair of the pronator quadratus muscle in patients undergoing surgical treatment for a distal radial fracture with volar plating. Patients and Methods. A total of 72 patients with a distal radial fracture were included in this randomized clinical trial. They were allocated to have the pronator quadratus muscle repaired or not, after volar locked plating of a distal radial fracture. The patients, the assessor, the primary investigator, and the statistician were blinded to the allocation. Randomization was irreversibly performed using a web application that guaranteed a secure and tamper-free assignment. The primary outcome measure was the Patient Rated Wrist Evaluation (PRWE) after 12 months. Secondary outcomes included the Disabilities of the Arm, Shoulder and Hand (DASH) score, pronation strength, grip strength, the range of pronation and supination, complications, and the operating time. Results. Of the 72 patients, 63 (87.5%) completed follow-up for the primary outcome measure: 31 (86.1%) from the non-repair group and 32 (88.9%) from the repair group. At the 12-month follow-up, the mean difference in PRWE of 5.47 (95% confidence interval (CI) -4.02 to 14.96) between the repair (mean 18.38 (95% CI 10.34 to 26.41)) and non-repair group (mean 12.90 (95% CI 7.55 to 18.25)) was not statistically significant (p = 0.253). There was a statistically significant difference between pronation strength, favouring non-repair. We found no difference in the other secondary outcomes. Conclusion. We found that repairing pronator quadratus made no difference to the clinical outcome, 12 months after volar plating of a distal radial fracture. We conclude that there is no functional advantage in repairing this muscle under these circumstances and advise against it. Cite this article: Bone Joint J 2019;101-B:1498–1505


The Bone & Joint Journal
Vol. 95-B, Issue 6 | Pages 855 - 860
1 Jun 2013
Gottliebsen M Møller-Madsen B Stødkilde-Jørgensen H Rahbek O

Permanent growth arrest of the longer bone is an option in the treatment of minor leg-length discrepancies. The use of a tension band plating technique to produce a temporary epiphysiodesis is appealing as it avoids the need for accurate timing of the procedure in relation to remaining growth. We performed an animal study to establish if control of growth in a long bone is possible with tension band plating. Animals (pigs) were randomised to temporary epiphysiodesis on either the right or left tibia. Implants were removed after ten weeks. Both tibiae were examined using MRI at baseline, and after ten and 15 weeks. The median interphyseal distance was significantly shorter on the treated tibiae after both ten weeks (p = 0.04) and 15 weeks (p = 0.04). On T. 1. -weighted images the metaphyseal water content was significantly reduced after ten weeks on the treated side (p = 0.04) but returned to values comparable with the untreated side at 15 weeks (p = 0.14). Return of growth was observed in all animals after removal of implants. Temporary epiphysiodesis can be obtained using tension band plating. The technique is not yet in common clinical practice but might avoid the need for the accurate timing of epiphysiodesis. Cite this article: Bone Joint J 2013;95-B:855–60


The aims of this study were to assess the efficacy of a newly designed radiological technique (the radial groove view) for the detection of protrusion of screws in the groove for the extensor pollicis longus tendon (EPL) during plating of distal radial fractures. We also aimed to determine the optimum position of the forearm to obtain this view. We initially analysed the anatomy of the EPL groove by performing three-dimensional CT on 51 normal forearms. The mean horizontal angle of the groove was 17.8° (14° to 23°). We found that the ideal position of the fluoroscopic beam to obtain this view was 20° in the horizontal plane and 5° in the sagittal plane. We then intra-operatively assessed the use of the radial groove view for detecting protrusion of screws in the EPL groove in 93 fractures that were treated by volar plating. A total of 13 protruding screws were detected. They were changed to shorter screws and these patients underwent CT scans of the wrist immediately post-operatively. There remained one screw that was protruding. These findings suggest that the use of the radial groove view intra-operatively is a good method of assessing the possible protrusion of screws into the groove of EPL when plating a fracture of the distal radius. Cite this article: Bone Joint J 2013;95-B:1372–6


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 9 | Pages 1214 - 1221
1 Sep 2008
Egol K Walsh M Tejwani N McLaurin T Wynn C Paksima N

We performed a prospective, randomised trial to evaluate the outcome after surgery of displaced, unstable fractures of the distal radius. A total of 280 consecutive patients were enrolled in a prospective database and 88 identified who met the inclusion criteria for surgery. They were randomised to receive either bridging external fixation with supplementary Kirschner-wire fixation or volar-locked plating with screws. Both groups were similar in terms of age, gender, hand dominance, fracture pattern, socio-economic status and medical co-morbidities. Although the patients treated by volar plating had a statistically significant early improvement in the range of movement of the wrist, this advantage diminished with time and in absolute terms the difference in range of movement was clinically unimportant. Radiologically, there were no clinically significant differences in the reductions, although more patients with AO/OTA (Orthopaedic Trauma Association) type C fractures were allocated to the external fixation group. The function at one year was similar in the two groups. No clear advantage could be demonstrated with either treatment but fewer re-operations were required in the external fixation group


The Bone & Joint Journal
Vol. 99-B, Issue 10 | Pages 1373 - 1380
1 Oct 2017
Rienmüller A Buchmann N Kirschke JS Meyer EL Gempt J Lehmberg J Meyer B Ryang YM

Aims. We aimed to retrospectively assess the accuracy and safety of CT navigated pedicle screws and to compare accuracy in the cervical and thoracic spine (C2-T8) with (COMB) and without (POST) prior anterior surgery (anterior cervical discectomy or corpectomy and fusion with ventral plating: ACDF/ACCF). Patients and Methods. A total of 592 pedicle screws, which were used in 107 consecutively operated patients (210 COMB, 382 POST), were analysed. The accuracy of positioning was determined according to the classification of Gertzbein and Robbins on post-operative CT scans. Results. High accuracy was achieved in 524 screws (88.5%), 192 (87.7%) in the cervical spine and 332 (89%) in the thoracic spine, respectively. The results in the two surgical groups were compared and a logistic regression mixed model was performed to analyse the risk of low accuracy. Significantly lower accuracy was found in the COMB group with 82.9% versus 91.6% in the POST group (p = 0.036). There were no neurological complications, but two vertebral artery lesions were recorded. Three patients underwent revision surgery for malpositioning of a screw. Although the risk of malpositioning of a screw after primary anterior surgery was estimated to be 2.4-times higher than with posterior surgery alone, the overall rates of complication and revision were low. Conclusion. We therefore conclude that CT navigated pedicle screws can be positioned safely although greater caution must be taken in patients who have previously undergone anterior surgery. Cite this article: Bone Joint J 2017;99-B:1373–80


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 9 | Pages 1247 - 1252
1 Sep 2011
Sinha A Edwin J Sreeharsha B Bhalaik V Brownson P

This study investigated the anatomical relationship between the clavicle and its adjacent vascular structures, in order to define safe zones, in terms of distance and direction, for drilling of the clavicle during osteosynthesis using a plate and screws following a fracture. We used reconstructed three-dimensional CT arteriograms of the head, neck and shoulder region. The results have enabled us to divide the clavicle into three zones based on the proximity and relationship of the vascular structures adjacent to it. The results show that at the medial end of the clavicle the subclavian vessels are situated behind it, with the vein intimately related to it. In some scans the vein was opposed to the posterior cortex of the clavicle. At the middle one-third of the clavicle the artery and vein are a mean of 17.02 mm (5.4 to 26.8) and 12.45 mm (5 to 26.1) from the clavicle, respectively, and at a mean angle of 50° (12 to 80) and 70° (38 to 100), respectively, to the horizontal. At the lateral end of the clavicle the artery and vein are at mean distances of 63.4 mm (46.8 to 96.5) and 75.67 mm (50 to 109), respectively. An appreciation of the information gathered from this study will help minimise the risk of inadvertent iatrogenic vascular injury during plating of the clavicle


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 2 | Pages 293 - 296
1 Mar 1985
Bell M Beauchamp C Kellam J McMurtry R

Excellent results can be achieved by plating fractures of the shaft of the humerus in patients with multiple injuries. This helps in nursing care and in the management of other injuries. In 38 patients admitted to a regional trauma centre, 39 humeral shaft fractures were plated. There were 27 men and 11 women, with an average age of 31.5 years. Fourteen of the humeral fractures were compound and 20 had significant comminution; 23 were fixed by a plate on the day of admission and all 39 by the twentieth day. Follow-up of 34 fractures showed that all had united, 33 primarily. All patients but one had a fully functional shoulder and no patient with a fractured humerus alone had lost any elbow movement. Complications were rare--one case each of non-union, fixation failure and infection. No permanent nerve injuries were produced at operation. The plating of fractures of the humerus in these circumstances has been shown to produce excellent results and has a place in the management of the patient with multiple injuries


Bone & Joint Research
Vol. 9, Issue 6 | Pages 314 - 321
1 Jun 2020
Bliven E Sandriesser S Augat P von Rüden C Hackl S

Aims

Evaluate if treating an unstable femoral neck fracture with a locking plate and spring-loaded telescoping screw system would improve construct stability compared to gold standard treatment methods.

Methods

A 31B2 Pauwels’ type III osteotomy with additional posterior wedge was cut into 30 fresh-frozen femur cadavers implanted with either: three cannulated screws in an inverted triangle configuration (CS), a sliding hip screw and anti-rotation screw (SHS), or a locking plate system with spring-loaded telescoping screws (LP). Dynamic cyclic compressive testing representative of walking with increasing weight-bearing was applied until failure was observed. Loss of fracture reduction was recorded using a high-resolution optical motion tracking system.


Bone & Joint Research
Vol. 4, Issue 2 | Pages 23 - 28
1 Feb 2015
Auston DA Werner FW Simpson RB

Objectives

This study tests the biomechanical properties of adjacent locked plate constructs in a femur model using Sawbones. Previous studies have described biomechanical behaviour related to inter-device distances. We hypothesise that a smaller lateral inter-plate distance will result in a biomechanically stronger construct, and that addition of an anterior plate will increase the overall strength of the construct.

Methods

Sawbones were plated laterally with two large-fragment locking compression plates with inter-plate distances of 10 mm or 1 mm. Small-fragment locking compression plates of 7-hole, 9-hole, and 11-hole sizes were placed anteriorly to span the inter-plate distance. Four-point bend loading was applied, and the moment required to displace the constructs by 10 mm was recorded.


The Bone & Joint Journal
Vol. 95-B, Issue 6 | Pages 815 - 819
1 Jun 2013
Yadav V Khare GN Singh S Kumaraswamy V Sharma N Rai AK Ramaswamy AG Sharma H

Both conservative and operative forms of treatment have been recommended for patients with a ‘floating shoulder’. We compared the results of conservative and operative treatment in 25 patients with this injury and investigated the use of the glenopolar angle (GPA) as an indicator of the functional outcome. A total of 13 patients (ten male and three female; mean age 32.5 years (24.7 to 40.4)) were treated conservatively and 12 patients (ten male and two female; mean age 33.67 years (24.6 to 42.7)) were treated operatively by fixation of the clavicular fracture alone. Outcome was assessed using the Herscovici score, which was also related to changes in the GPA at one year post-operatively.

The mean Herscovici score was significantly better three months and two years after the injury in the operative group (p < 0.001 and p = 0.003, respectively). There was a negative correlation between the change in GPA and the Herscovici score at two years follow-up in both the conservative and operative groups, but neither were statistically significant (r = -0.295 and r = -0.19, respectively). There was a significant difference between the pre- and post-operative GPA in the operative group (p = 0.017).

When compared with conservative treatment, fixation of the clavicle alone gives better results in the treatment of patients with a floating shoulder. The GPA changes significantly with fixation of clavicle alone but there is no significant correlation between the pre-injury GPA and the final clinical outcome in these patients.

Cite this article: Bone Joint J 2013;95-B:815–19.


Aims

Surgical treatment of hip fracture is challenging; the bone is porotic and fixation failure can be catastrophic. Novel implants are available which may yield superior clinical outcomes. This study compared the clinical effectiveness of the novel X-Bolt Hip System (XHS) with the sliding hip screw (SHS) for the treatment of fragility hip fractures.

Methods

We conducted a multicentre, superiority, randomized controlled trial. Patients aged 60 years and older with a trochanteric hip fracture were recruited in ten acute UK NHS hospitals. Participants were randomly allocated to fixation of their fracture with XHS or SHS. A total of 1,128 participants were randomized with 564 participants allocated to each group. Participants and outcome assessors were blind to treatment allocation. The primary outcome was the EuroQol five-dimension five-level health status (EQ-5D-5L) utility at four months. The minimum clinically important difference in utility was pre-specified at 0.075. Secondary outcomes were EQ-5D-5L utility at 12 months, mortality, residential status, mobility, revision surgery, and radiological measures.


Bone & Joint Research
Vol. 9, Issue 9 | Pages 534 - 542
1 Sep 2020
Varga P Inzana JA Fletcher JWA Hofmann-Fliri L Runer A Südkamp NP Windolf M

Aims

Fixation of osteoporotic proximal humerus fractures remains challenging even with state-of-the-art locking plates. Despite the demonstrated biomechanical benefit of screw tip augmentation with bone cement, the clinical findings have remained unclear, potentially as the optimal augmentation combinations are unknown. The aim of this study was to systematically evaluate the biomechanical benefits of the augmentation options in a humeral locking plate using finite element analysis (FEA).

Methods

A total of 64 cement augmentation configurations were analyzed using six screws of a locking plate to virtually fix unstable three-part fractures in 24 low-density proximal humerus models under three physiological loading cases (4,608 simulations). The biomechanical benefit of augmentation was evaluated through an established FEA methodology using the average peri-screw bone strain as a validated predictor of cyclic cut-out failure.


The Journal of Bone & Joint Surgery British Volume
Vol. 38-B, Issue 3 | Pages 709 - 713
1 Aug 1956
McDougall A

1. A case is described in which a malignant tumour developed in the soft tissues at the site of a bone-plating operation performed thirty years before.

2. The plate and screws were found to be composed of dissimilar metals and a difference of potential existed between them.

3. A careful consideration of the history and clinical course indicates that the tumour arose because of the presence of the metals.


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 1 | Pages 86 - 87
1 Jan 1991
Salam A Eyres K Cleary J el-Sayed H

Sixty closed fractures of the tibia were treated by open reduction and internal fixation with plates and screws. Half the operations were performed with a thigh tourniquet and half without. In the tourniquet group, there were six cases with erythema and induration of the wound; in the other group there were no such complications. Despite negative bacterial cultures, superficial infection of the inflamed wounds was suspected. It is suggested that a tourniquet may predispose tissues to infection, and its use is not recommended during operations for internal fixation of the tibia.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 7 | Pages 984 - 988
1 Jul 2010
Guo JJ Tang N Yang HL Tang TS

We compared the outcome of closed intramedullary nailing with minimally invasive plate osteosynthesis using a percutaneous locked compression plate in patients with a distal metaphyseal fracture in a prospective study.

A total of 85 patients were randomised to operative stabilisation either by a closed intramedullary nail (44) or by minimally invasive osteosynthesis with a compression plate (41). Pre-operative variables included the patients’ age and the side and pattern of the fracture. Peri-operative variables were the operating time and the radiation time. Postoperative variables were wound problems, the time to union of the fracture, the functional American Orthopaedic Foot and Ankle surgery score and removal of hardware.

We found no significant difference in the pre-operative variables or in the time to union in the two groups. However, the mean radiation time and operating time were significantly longer in the locked compression plate group (3.0 vs 2.12 minutes, p < 0.001, and 97.9 vs 81.2 minutes, p < 0.001, respectively). After one year, all the fractures had united. Patients who had intramedullary nailing had a higher mean pain score, but better function, alignment and total American Orthopaedic Foot and Ankle surgery scores, although the differences were not statistically significant (p = 0.234, p = 0.157, p = 0.897, p = 0.177 respectively). Three (6.8%) patients in the intramedullary nailing group and six (14.6%) in the locked compression plate group showed delayed wound healing, and 37 (84.1%) in the former group and 38 (92.7%) in the latter group expressed a wish to have the implant removed.

We conclude that both closed intramedullary nailing and a percutaneous locked compression plate can be used safely to treat Orthopaedic Trauma Association type-43A distal metaphyseal fractures of the tibia. However, closed intramedullary nailing has the advantage of a shorter operating and radiation time and easier removal of the implant. We therefore prefer closed intramedullary nailing for patients with these fractures.


Bone & Joint Open
Vol. 2, Issue 8 | Pages 646 - 654
16 Aug 2021
Martin JR Saunders PE Phillips M Mitchell SM Mckee MD Schemitsch EH Dehghan N

Aims. The aims of this network meta-analysis (NMA) were to examine nonunion rates and functional outcomes following various operative and nonoperative treatments for displaced mid-shaft clavicle fractures. Methods. Initial search strategy incorporated MEDLINE, PubMed, Embase, and the Cochrane Library for relevant randomized controlled trials (RCTs). Four treatment arms were created: nonoperative (NO); intramedullary nailing (IMN); reconstruction plating (RP); and compression/pre-contoured plating (CP). A Bayesian NMA was conducted to compare all treatment options for outcomes of nonunion, malunion, and function using the Disabilities of the Arm Shoulder and Hand (DASH) and Constant-Murley Shoulder Outcome scores. Results. In all, 19 RCTs consisting of 1,783 clavicle fractures were included in the NMA. All surgical options demonstrated a significantly lower odds ratio (OR) of nonunion in comparison to nonoperative management: CP versus NO (OR 0.08; 95% confidence interval (CI) 0.04 to 0.17); IMN versus NO (OR 0.07; 95% CI 0.02 to 0.19); RP versus NO (OR 0.07; 95% CI: 0.01 to 0.24). Compression plating was the only treatment to demonstrate significantly lower DASH scores relative to NO at six weeks (mean difference -10.97; 95% CI -20.69 to 1.47). Conclusion. Surgical fixation demonstrated a lower risk of nonunion compared to nonoperative management. Compression plating resulted in significantly less disability early after surgery compared to nonoperative management. These results demonstrate possible early improved functional outcomes with compression plating compared to nonoperative treatment. Surgical fixation of mid-shaft clavicle fractures with compression plating may result in quicker return to activity by rendering patients less disabled early after surgery. Cite this article: Bone Jt Open 2021;2(8):646–654


Bone & Joint 360
Vol. 11, Issue 6 | Pages 26 - 30
1 Dec 2022

The December 2022 Wrist & Hand Roundup. 360. looks at: Anti-tumour necrosis factor therapy for early-stage Dupuytren’s disease; Patient experiences of scaphoid waist fractures and their treatment; Postoperative complications following open a1 pulley release for a trigger finger or thumb; How certain are findings in distal radius fractures: a systematic review of randomized controlled trials; Partial wrist denervation in wrist osteoarthritis: patient-reported outcomes and objective function; Dorsal bridge plating versus bridging external fixation for management of complex distal radius fractures; How is reduction lost in distal radius fractures in females aged 50 years and older; The HAND-Q: psychometrics of a new patient-reported outcome measure for clinical and research applications


Bone & Joint 360
Vol. 11, Issue 6 | Pages 31 - 34
1 Dec 2022

The December 2022 Shoulder & Elbow Roundup. 360. looks at: Biceps tenotomy versus soft-tissue tenodesis in females aged 60 years and older with rotator cuff tears; Resistance training combined with corticosteroid injections or tendon needling in patients with lateral elbow tendinopathy; Two-year functional outcomes of completely displaced midshaft clavicle fractures in adolescents; Patients who undergo rotator cuff repair can safely return to driving at two weeks postoperatively; Are two plates better than one? A systematic review of dual plating for acute midshaft clavicle fractures; Treatment of acute distal biceps tendon ruptures; Rotator cuff tendinopathy: disability associated with depression rather than pathology severity; Coonrad-Morrey total elbow arthroplasty implications in young patients with post-traumatic sequelae


Bone & Joint 360
Vol. 13, Issue 4 | Pages 31 - 35
2 Aug 2024

The August 2024 Trauma Roundup. 360. looks at: Does topical vancomycin prevent fracture-related infections in closed fractures undergoing open reduction and internal fixation? A randomized controlled trial; Is postoperative splinting advantageous after upper limb fracture surgery?; Does suprapatellar nailing resolve knee pain?; Locking versus non-locking plate fixation in comminuted talar neck fractures: a biomechanical study using cadaveric specimens; Revolutionizing recovery metrics: PROMIS versus SMFA in orthopaedic trauma care; Dorsal hook plating of patella fractures: reliable fixation and satisfactory outcomes; The impact of obesity on subtrochanteric femur fracture outcomes; Low-dose NSAIDs (ketorolac) and cytokine modulation in orthopaedic polytrauma: a detailed analysis


Bone & Joint Research
Vol. 11, Issue 2 | Pages 49 - 60
1 Feb 2022
Li J Wong RMY Chung YL Leung SSY Chow SK Ip M Cheung W

Aims. With the ageing population, fragility fractures have become one of the most common conditions. The objective of this study was to investigate whether microbiological outcomes and fracture-healing in osteoporotic bone is worse than normal bone with fracture-related infection (FRI). Methods. A total of 120 six-month-old Sprague-Dawley (SD) rats were randomized to six groups: Sham, sham + infection (Sham-Inf), sham with infection + antibiotics (Sham-Inf-A), ovariectomized (OVX), OVX + infection (OVX-Inf), and OVX + infection + antibiotics (OVX-Inf-A). Open femoral diaphysis fractures with Kirschner wire fixation were performed. Staphylococcus aureus at 4 × 10. 4. colony-forming units (CFU)/ml was inoculated. Rats were euthanized at four and eight weeks post-surgery. Radiography, micro-CT, haematoxylin-eosin, mechanical testing, immunohistochemistry (IHC), gram staining, agar plating, crystal violet staining, and scanning electron microscopy were performed. Results. Agar plating analysis revealed a higher bacterial load in bone (p = 0.002), and gram staining showed higher cortical bone colonization (p = 0.039) in OVX-Inf compared to Sham-Inf. OVX-Inf showed significantly increased callus area (p = 0.013), but decreased high-density bone volume (p = 0.023) compared to Sham-Inf. IHC staining showed a significantly increased expression of TNF-α in OVX-Inf compared to OVX (p = 0.049). Significantly reduced bacterial load on bone (p = 0.001), enhanced ultimate load (p = 0.001), and energy to failure were observed in Sham-Inf-A compared to Sham-Inf (p = 0.028), but not in OVX-Inf-A compared to OVX-Inf. Conclusion. In osteoporotic bone with FRI, infection was more severe with more bone lysis and higher bacterial load, and fracture-healing was further delayed. Systemic antibiotics significantly reduced bacterial load and enhanced callus quality and strength in normal bone with FRI, but not in osteoporotic bone. Cite this article: Bone Joint Res 2022;11(2):49–60


Bone & Joint 360
Vol. 12, Issue 3 | Pages 32 - 35
1 Jun 2023

The June 2023 Trauma Roundup. 360. looks at: Aspirin or low-molecular-weight heparin for thromboprophylaxis?; Lateral plating or retrograde nailing for distal femur fractures?; Sciatic nerve palsy after acetabular fixation: what about patient position?; How reliable is the new OTA/AO classification for trochanteric hip fractures?; Young hip fractures: is a medial buttress the answer?; When is the best time to ‘flap’ an open fracture?; The mortality burden of nonoperatively managed hip fractures


Bone & Joint Open
Vol. 5, Issue 3 | Pages 227 - 235
18 Mar 2024
Su Y Wang Y Fang C Tu Y Chang C Kuan F Hsu K Shih C

Aims. The optimal management of posterior malleolar ankle fractures, a prevalent type of ankle trauma, is essential for improved prognosis. However, there remains a debate over the most effective surgical approach, particularly between screw and plate fixation methods. This study aims to investigate the differences in outcomes associated with these fixation techniques. Methods. We conducted a comprehensive review of clinical trials comparing anteroposterior (A-P) screws, posteroanterior (P-A) screws, and plate fixation. Two investigators validated the data sourced from multiple databases (MEDLINE, EMBASE, and Web of Science). Following PRISMA guidelines, we carried out a network meta-analysis (NMA) using visual analogue scale and American Orthopaedic Foot and Ankle Score (AOFAS) as primary outcomes. Secondary outcomes included range of motion limitations, radiological outcomes, and complication rates. Results. The NMA encompassed 13 studies, consisting of four randomized trials and eight retrospective ones. According to the surface under the cumulative ranking curve-based ranking, the A-P screw was ranked highest for improvements in AOFAS and exhibited lowest in infection and peroneal nerve injury incidence. The P-A screws, on the other hand, excelled in terms of VAS score improvements. Conversely, posterior buttress plate fixation showed the least incidence of osteoarthritis grade progression, postoperative articular step-off ≥ 2 mm, nonunions, and loss of ankle dorsiflexion ≥ 5°, though it underperformed in most other clinical outcomes. Conclusion. The NMA suggests that open plating is more likely to provide better radiological outcomes, while screw fixation may have a greater potential for superior functional and pain results. Nevertheless, clinicians should still consider the fragment size and fracture pattern, weighing the advantages of rigid biomechanical fixation against the possibility of soft-tissue damage, to optimize treatment results. Cite this article: Bone Jt Open 2024;5(3):227–235


The Bone & Joint Journal
Vol. 103-B, Issue 11 | Pages 1648 - 1655
1 Nov 2021
Jeong S Hwang K Oh C Kim J Sohn OJ Kim JW Cho Y Park KC

Aims. The incidence of atypical femoral fractures (AFFs) continues to increase. However, there are currently few long-term studies on the complications of AFFs and factors affecting them. Therefore, we attempted to investigate the outcomes, complications, and risk factors for complication through mid-term follow-up of more than three years. Methods. From January 2003 to January 2016, 305 patients who underwent surgery for AFFs at six hospitals were enrolled. After exclusion, a total of 147 patients were included with a mean age of 71.6 years (48 to 89) and 146 of whom were female. We retrospectively evaluated medical records, and reviewed radiographs to investigate the fracture site, femur bowing angle, presence of delayed union or nonunion, contralateral AFFs, and peri-implant fracture. A statistical analysis was performed to identify the significance of associated factors. Results. The mean follow-up period was 70.2 months (36 to 191). There were 146 AFFs (99.3%) in female patients and the mean age was 71.6 years (48 to 89). The AFFs were located in the subtrochanter and shaft in 52 cases (35.4%) and 95 (64.6%), respectively. The preoperative mean anterior/lateral femoral bowing angles were 10.5° (SD 5.7°)/6.1° (SD 6.2°). The postoperative mean anterior/lateral bowing values were changed by 8.7° (SD 5.4°)/4.6° (SD 5.9°). Bisphosphonates had been used contemporarily in 115 AFFs (78.2%) for a mean of 52.4 months (1 to 204; SD 45.5) preoperatively. Nailing was performed in 133 AFFs (90.5%), and union was obtained at a mean of 23.6 weeks (7 to 85). Delayed union occurred in 41 (27.9%), and nonunion occurred in 13 (8.8%). Contralateral AFF occurred in 79 patients (53.7%), and the use of a bisphosphonate significantly influenced the occurrence of contralateral AFFs (p = 0.019). Peri-implant fractures occurred in a total of 13 patients (8.8%), and a significant increase was observed in cases with plating (p = 0.021) and high grade of postoperative anterolateral bowing (p = 0.044). Conclusion. The use of a bisphosphonate was found to be a risk factor for contralateral AFF, and high-grade postoperative anterolateral bowing and plate fixation significantly increased the occurrence of peri-implant fractures. Long-term follow-up studies on the bilaterality of AFFs and peri-implant fractures are warranted. Cite this article: Bone Joint J 2021;103-B(11):1648–1655


Bone & Joint Open
Vol. 1, Issue 9 | Pages 549 - 555
11 Sep 2020
Sonntag J Landale K Brorson S Harris IA

Aims. The aim of this study was to investigate surgeons’ reported change of treatment preference in response to the results and conclusion from a randomized contolled trial (RCT) and to study patterns of change between subspecialties and nationalities. Methods. Two questionnaires were developed through the Delphi process for this cross-sectional survey of surgical preference. The first questionnaire was sent out before the publication of a RCT and the second questionnaire was sent out after publication. The RCT investigated repair or non-repair of the pronator quadratus (PQ) muscle during volar locked plating of distal radial fractures (DRFs). Overall, 380 orthopaedic surgeons were invited to participate in the first questionnaire, of whom 115 replied. One hundred surgeons were invited to participate in the second questionnaire. The primary outcome was the proportion of surgeons for whom a treatment change was warranted, who then reported a change of treatment preference following the RCT. Secondary outcomes included the reasons for repair or non-repair, reasons for and against following the RCT results, and difference of preferred treatment of the PQ muscle between surgeons of different nationalities, qualifications, years of training, and number of procedures performed per year. Results. Of the 100 surgeons invited for the second questionnaire, 74 replied. For the primary outcome, six of 32 surgeons (19%), who usually repaired the PQ muscle and therefore a change of treatment preference was warranted, reported a change of treatment preference based on the RCT publication. Of the secondary outcomes, restoring anatomy was the most common response for repairing the PQ muscle. Conclusion. The majority of the orthopaedic surgeons, where a change of treatment preference was warranted based on the results and conclusion of a RCT, did not report willingness to change their treatment preference. Cite this article: Bone Joint Open 2020;1-9:549–555


Bone & Joint Research
Vol. 7, Issue 6 | Pages 422 - 429
1 Jun 2018
Acklin YP Zderic I Inzana JA Grechenig S Schwyn R Richards RG Gueorguiev B

Aims. Plating displaced proximal humeral fractures is associated with a high rate of screw perforation. Dynamization of the proximal screws might prevent these complications. The aim of this study was to develop and evaluate a new gliding screw concept for plating proximal humeral fractures biomechanically. Methods. Eight pairs of three-part humeral fractures were randomly assigned for pairwise instrumentation using either a prototype gliding plate or a standard PHILOS plate, and four pairs were fixed using the gliding plate with bone cement augmentation of its proximal screws. The specimens were cyclically tested under progressively increasing loading until perforation of a screw. Telescoping of a screw, varus tilting and screw migration were recorded using optical motion tracking. Results. Mean initial stiffness (N/mm) was 581.3 (. sd. 239.7) for the gliding plate, 631.5 (. sd. 160.0) for the PHILOS and 440.2 (. sd. 97.6) for the gliding augmented plate without significant differences between the groups (p = 0.11). Mean varus tilting (°) after 7500 cycles was comparable between the gliding plate (2.6; . sd. 1.9), PHILOS (1.2; . sd. 0.6) and gliding augmented plate (1.7; . sd. 0.9) (p = 0.10). Similarly, mean screw migration(mm) after 7500 cycles was similar between the gliding plate (3.02; . sd. 2.85), PHILOS (1.30; . sd. 0.44) and gliding augmented plate (2.83; . sd. 1.18) (p = 0.13). Mean number of cycles until failure with 5° varus tilting were 12702 (. sd. 3687) for the gliding plate, 13948 (. sd. 1295) for PHILOS and 13189 (. sd. 2647) for the gliding augmented plate without significant differences between the groups (p = 0.66). Conclusion. Biomechanically, plate fixation using a new gliding screw technology did not show considerable advantages in comparison with fixation using a standard PHILOS plate. Based on the finding of telescoping of screws, however, it may represent a valid approach for further investigations into how to avoid the cut-out of screws. Cite this article: Y. P. Acklin, I. Zderic, J. A. Inzana, S. Grechenig, R. Schwyn, R. G. Richards, B. Gueorguiev. Biomechanical evaluation of a new gliding screw concept for the fixation of proximal humeral fractures. Bone Joint Res 2018;7:422–429. DOI: 10.1302/2046-3758.76.BJR-2017-0356.R1


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 4 | Pages 527 - 534
1 Apr 2010
Streubel PN Gardner MJ Morshed S Collinge CA Gallagher B Ricci WM

It is unclear whether there is a limit to the amount of distal bone required to support fixation of supracondylar periprosthetic femoral fractures. This retrospective multicentre study evaluated lateral locked plating of periprosthetic supracondylar femoral fractures and compared the results according to extension of the fracture distal with the proximal border of the femoral prosthetic component. Between 1999 and 2008, 89 patients underwent lateral locked plating of a supracondylar periprosthetic femoral fracture, of whom 61 patients with a mean age of 72 years (42 to 96) comprising 53 women, were available after a minimum follow-up of six months or until fracture healing. Patients were grouped into those with fractures located proximally (28) and those with fractures that extended distal to the proximal border of the femoral component (33). Delayed healing and nonunion occurred respectively in five (18%) and three (11%) of more proximal fractures, and in two (6%) and five (15%) of the fractures with distal extension (p = 0.23 for delayed healing; p = 0.72 for nonunion, Fisher’s exact test). Four construct failures (14%) occurred in more proximal fractures, and three (9%) in fractures with distal extension (p = 0.51). Of the two deep infections that occurred in each group, one resolved after surgical debridement and antibiotics, and one progressed to a nonunion. Extreme distal periprosthetic supracondylar fractures of the femur are not a contra-indication to lateral locked plating. These fractures can be managed with internal fixation, with predictable results, similar to those seen in more proximal fractures


The Bone & Joint Journal
Vol. 97-B, Issue 10 | Pages 1370 - 1376
1 Oct 2015
Jordan RW Saithna A

This article is a systematic review of the published literature about the biomechanics, functional outcome and complications of intramedullary nailing of fractures of the distal radius. We searched the Medline and EMBASE databases and included all studies which reported the outcome of intramedullary (IM) nailing of fractures of the distal radius. Data about functional outcome, range of movement (ROM), strength and complications, were extracted. The studies included were appraised independently by both authors using a validated quality assessment scale for non-controlled studies and the CONSORT statement for randomised controlled trials (RCTs). The search strategy revealed 785 studies, of which 16 were included for full paper review. These included three biomechanical studies, eight case series and five randomised controlled trials (RCTs). . The biomechanical studies concluded that IM nails were at least as strong as locking plates. The clinical studies reported that IM nailing gave a comparable ROM, functional outcome and grip strength to other fixation techniques. . However, the mean complication rate of intramedullary nailing was 17.6% (0% to 50%). This is higher than the rates reported in contemporary studies for volar plating. It raises concerns about the role of intramedullary nailing, particularly when comparative studies have failed to show that it has any major advantage over other techniques. Further adequately powered RCTs comparing the technique to both volar plating and percutaneous wire fixation are needed. Cite this article: Bone Joint J 2015;97-B:1370–6


Bone & Joint Research
Vol. 2, Issue 10 | Pages 206 - 209
1 Oct 2013
Griffin XL McArthur J Achten J Parsons N Costa ML

Fractures of the proximal femur are one of the greatest challenges facing the medical community, constituting a heavy socioeconomic burden worldwide. Controversy exists regarding the optimal treatment for patients with unstable trochanteric proximal femoral fractures. The recognised treatment alternatives are extramedullary fixation usually with a sliding hip screw and intramedullary fixation with a cephalomedullary nail. Current evidence suggests that best results and lowest complication rates occur using a sliding hip screw. Complications in these difficult fractures are relatively common regardless of type of treatment. We believe that a novel device, the X-Bolt dynamic plating system, may offer superior fixation over a sliding hip screw with lower reoperation risk and better function. We therefore propose to investigate the clinical effectiveness of the X-bolt dynamic plating system compared with standard sliding hip screw fixation within the framework of a the larger WHiTE (Warwick Hip Trauma Evaluation) Comprehensive Cohort Study. Cite this article: Bone Joint Res 2013;2:206–9


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 4 | Pages 426 - 433
1 Apr 2009
Musahl V Tarkin I Kobbe P Tzioupis C Siska PA Pape H

The operative treatment of displaced fractures of the tibial plateau is challenging. Recent developments in the techniques of internal fixation, including the development of locked plating and minimal invasive techniques have changed the treatment of these fractures. We review current surgical approaches and techniques, improved devices for internal fixation and the clinical outcome after utilisation of new methods for locked plating


The Bone & Joint Journal
Vol. 98-B, Issue 3 | Pages 298 - 300
1 Mar 2016
Fullilove S Gozzard C

The results of the DRAFFT (distal radius acute fracture fixation trial) study, which compared volar plating with Kirschner (K-) wire fixation for dorsally displaced fractures of the distal radius, were published in August 2014. The use of K-wires to treat these fractures is now increasing, with a concomitant decline in the use of volar locking plates. We provide a critical appraisal of the DRAFFT study and question whether surgeons have been unduly influenced by its headline conclusions. Cite this article: Bone Joint J 2016;98-B:298–300


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 593 - 601
1 Jun 2023
Scott CEH Yapp LZ Howard T Patton JT Moran M

Periprosthetic femoral fractures are increasing in incidence, and typically occur in frail elderly patients. They are similar to pathological fractures in many ways. The aims of treatment are the same, including 'getting it right first time' with a single operation, which allows immediate unrestricted weightbearing, with a low risk of complications, and one that avoids the creation of stress risers locally that may predispose to further peri-implant fracture. The surgical approach to these fractures, the associated soft-tissue handling, and exposure of the fracture are key elements in minimizing the high rate of complications. This annotation describes the approaches to the femur that can be used to facilitate the surgical management of peri- and interprosthetic fractures of the femur at all levels using either modern methods of fixation or revision arthroplasty.

Cite this article: Bone Joint J 2023;105-B(6):593–601.


Bone & Joint 360
Vol. 12, Issue 2 | Pages 34 - 36
1 Apr 2023

The April 2023 Trauma Roundup360 looks at: Displaced femoral neck fractures in patients aged 55 to 70 years: internal fixation or total hip arthroplasty?; Tibial plateau fractures: continuous passive motion approves range of motion; Lisfranc fractures: to fuse or not to fuse, that is the question; Is hardware removal after clavicle fracture plate fixation beneficial?; Fixation to coverage in Grade IIIB open fractures – what’s the time window?; Nonoperative versus locking plate fixation in the proximal humerus; Retrograde knee nailing or lateral plate for distal femur fractures?


Bone & Joint 360
Vol. 12, Issue 6 | Pages 31 - 34
1 Dec 2023

The December 2023 Shoulder & Elbow Roundup360 looks at: Clavicle fractures: is the evidence changing practice?; Humeral shaft fractures, and another meta-analysis…let’s wait for the trials now!; Hemiarthroplasty or total elbow arthroplasty for distal humeral fractures…what does the registry say?; What to do with a first-time shoulder dislocation?; Deprivation indices and minimal clinically important difference for patient-reported outcomes after arthroscopic rotator cuff repair; Prospective randomized clinical trial of arthroscopic repair versus debridement for partial subscapularis tears; Long-term follow-up following closed reduction and early movement for simple dislocation of the elbow; Sternoclavicular joint reconstruction for traumatic acute and chronic anterior and posterior instability.


Bone & Joint 360
Vol. 13, Issue 2 | Pages 35 - 38
1 Apr 2024

The April 2024 Trauma Roundup360 looks at: The infra-acetabular screw in acetabular fracture surgery; Is skin traction helpful in patients with intertrochanteric hip fractures?; Reducing pain and improving function following hip fracture surgery; Are postoperative splints helpful following ankle fracture fixation?; Biomechanics of internal fixation in Hoffa fractures: a comparison of four different constructs; Dual-plate fixation of periprosthetic distal femur fractures; Do direct oral anticoagulants necessarily mean a delay to hip fracture surgery?; Plate or retrograde nail for low distal femur fractures?.


Bone & Joint 360
Vol. 13, Issue 2 | Pages 30 - 33
1 Apr 2024

The April 2024 Shoulder & Elbow Roundup360 looks at: Acute rehabilitation following traumatic anterior shoulder dislocation (ARTISAN): pragmatic, multicentre, randomized controlled trial; Prevalence and predisposing factors of neuropathic pain in patients with rotator cuff tears; Are two plates better than one? The clavicle fracture reimagined; A single cell atlas of frozen shoulder capsule identifies features associated with inflammatory fibrosis resolution; Complication rates and deprivation go hand in hand with total shoulder arthroplasty; Longitudinal instability injuries of the forearm; A better than “best-fit circle” method for glenoid bone loss assessment; 3D supraspinatus muscle volume and intramuscular fatty infiltration after arthroscopic rotator cuff repair.


Bone & Joint Open
Vol. 4, Issue 7 | Pages 516 - 522
10 Jul 2023
Mereddy P Nallamilli SR Gowda VP Kasha S Godey SK Nallamilli RR GPRK R Meda VGR

Aims

Musculoskeletal infection is a devastating complication in both trauma and elective orthopaedic surgeries that can result in significant morbidity. Aim of this study was to assess the effectiveness and complications of local antibiotic impregnated dissolvable synthetic calcium sulphate beads (Stimulan Rapid Cure) in the hands of different surgeons from multiple centres in surgically managed bone and joint infections.

Methods

Between January 2019 and December 2022, 106 patients with bone and joint infections were treated by five surgeons in five hospitals. Surgical debridement and calcium sulphate bead insertion was performed for local elution of antibiotics in high concentration. In all, 100 patients were available for follow-up at regular intervals. Choice of antibiotic was tailor made for each patient in consultation with microbiologist based on the organism grown on culture and the sensitivity. In majority of our cases, we used a combination of vancomycin and culture sensitive heat stable antibiotic after a thorough debridement of the site. Primary wound closure was achieved in 99 patients and a split skin graft closure was done in one patient. Mean follow-up was 20 months (12 to 30).


Bone & Joint Open
Vol. 5, Issue 11 | Pages 1020 - 1026
11 Nov 2024
Pigeolet M Sana H Askew MR Jaswal S Ortega PF Bradley SR Shah A Mita C Corlew DS Saeed A Makasa E Agarwal-Harding KJ

Aims

Lower limb fractures are common in low- and middle-income countries (LMICs) and represent a significant burden to the existing orthopaedic surgical infrastructure. In high income country (HIC) settings, internal fixation is the standard of care due to its superior outcomes. In LMICs, external fixation is often the surgical treatment of choice due to limited supplies, cost considerations, and its perceived lower complication rate. The aim of this systematic review protocol is identifying differences in rates of infection, nonunion, and malunion of extra-articular femoral and tibial shaft fractures in LMICs treated with either internal or external fixation.

Methods

This systematic review protocol describes a broad search of multiple databases to identify eligible papers. Studies must be published after 2000, include at least five patients, patients must be aged > 16 years or treated as skeletally mature, and the paper must describe a fracture of interest and at least one of our primary outcomes of interest. We did not place restrictions on language or journal. All abstracts and full texts will be screened and extracted by two independent reviewers. Risk of bias and quality of evidence will be analyzed using standardized appraisal tools. A random-effects meta-analysis followed by a subgroup analysis will be performed, given the anticipated heterogeneity among studies, if sufficient data are available.


The Bone & Joint Journal
Vol. 105-B, Issue 2 | Pages 112 - 123
1 Feb 2023
Duckworth AD Carter TH Chen MJ Gardner MJ Watts AC

Despite being one of the most common injuries around the elbow, the optimal treatment of olecranon fractures is far from established and stimulates debate among both general orthopaedic trauma surgeons and upper limb specialists. It is almost universally accepted that stable non-displaced fractures can be safely treated nonoperatively with minimal specialist input. Internal fixation is recommended for the vast majority of displaced fractures, with a range of techniques and implants to choose from. However, there is concern regarding the complication rates, largely related to symptomatic metalwork resulting in high rates of implant removal. As the number of elderly patients sustaining these injuries increases, we are becoming more aware of the issues associated with fixation in osteoporotic bone and the often fragile soft-tissue envelope in this group. Given this, there is evidence to support an increasing role for nonoperative management in this high-risk demographic group, even in those presenting with displaced and/or multifragmentary fracture patterns. This review summarizes the available literature to date, focusing predominantly on the management techniques and available implants for stable fractures of the olecranon. It also offers some insights into the potential avenues for future research, in the hope of addressing some of the pertinent questions that remain unanswered.

Cite this article: Bone Joint J 2023;105-B(2):112–123.


The Bone & Joint Journal
Vol. 96-B, Issue 7 | Pages 963 - 969
1 Jul 2014
Mellstrand-Navarro C Pettersson HJ Tornqvist H Ponzer S

The aim of this study was to investigate the epidemiology of fractures of the distal radius in the Swedish population and to review the methods used to treat them between 2005 and 2010. The study population consisted of every patient in Sweden who was diagnosed with a fracture of the wrist between 1 January 2005 and 31 December 2010. There were 177 893 fractures of the distal radius. The incidence rate in the total population was 32 per 10 000 person-years. The mean age of the patients was 44 years (0 to 104). The proportion of fractures treated operatively increased from 16% in 2005 to 20% in 2010. The incidence rate for plate fixation in the adult population increased 3.61 fold. The incidence rate for external fixation decreased by 67%. The change was greatest in the 50 years to 74 years age group. In Sweden, there is an increasing tendency to operate on fractures of the distal radius. The previously reported increase in the use of plating is confirmed: it has increased more than threefold over a five-year period. Cite this article: Bone Joint J 2014;96-B:963–9


Bone & Joint 360
Vol. 13, Issue 1 | Pages 22 - 26
1 Feb 2024

The February 2024 Wrist & Hand Roundup360 looks at: Occupational therapy for thumb carpometacarpal osteoarthritis?; Age and patient-reported benefits from operative management of intra-articular distal radius fractures: a meta-regression analysis; Long-term outcomes of nonsurgical treatment of thumb carpometacarpal osteoarthritis: a cohort study; Semi-occlusive dressing versus surgery in fingertip injuries: a randomized controlled trial; Re-fracture in partial union of the scaphoid waist?; The WALANT distal radius fracture: a systematic review; Endoscopic carpal tunnel release with or without hand therapy?; Ten-year trends in the level of evidence in hand surgery.


Bone & Joint 360
Vol. 12, Issue 4 | Pages 32 - 35
1 Aug 2023

The August 2023 Trauma Roundup360 looks at: A comparison of functional cast and volar-flexion ulnar deviation for dorsally displaced distal radius fractures; Give your stable ankle fractures some AIR!; Early stabilization of rib fractures – an effective thing to do?; Locked plating versus nailing for proximal tibia fractures: A multicentre randomized controlled trial; Time to flap coverage in open tibia fractures; Does tranexamic acid affect the incidence of heterotropic ossification around the elbow?; High BMI – good or bad in surgical fixation of hip fractures?