Advertisement for orthosearch.org.uk
Results 1 - 50 of 81
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1567 - 1572
1 Nov 2012
Berkes MB Little MTM Lazaro LE Sculco PK Cymerman RM Daigl M Helfet DL Lorich DG

It has previously been suggested that among unstable ankle fractures, the presence of a malleolar fracture is associated with a worse outcome than a corresponding ligamentous injury. However, previous studies have included heterogeneous groups of injury. The purpose of this study was to determine whether any specific pattern of bony and/or ligamentous injury among a series of supination-external rotation type IV (SER IV) ankle fractures treated with anatomical fixation was associated with a worse outcome. We analysed a prospective cohort of 108 SER IV ankle fractures with a follow-up of one year. Pre-operative radiographs and MRIs were undertaken to characterise precisely the pattern of injury. Operative treatment included fixation of all malleolar fractures. Post-operative CT was used to assess reduction. The primary and secondary outcome measures were the Foot and Ankle Outcome Score (FAOS) and the range of movement of the ankle. There were no clinically relevant differences between the four possible SER IV fracture pattern groups with regard to the FAOS or range of movement. In this population of strictly defined SER IV ankle injuries, the presence of a malleolar fracture was not associated with a significantly worse clinical outcome than its ligamentous injury counterpart. Other factors inherent to the injury and treatment may play a more important role in predicting outcome


The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 512 - 521
1 May 2019
Carter TH Duckworth AD White TO

Abstract. The medial malleolus, once believed to be the primary stabilizer of the ankle, has been the topic of conflicting clinical and biomechanical data for many decades. Despite the relevant surgical anatomy being understood for almost 40 years, the optimal treatment of medial malleolar fractures remains unclear, whether the injury occurs in isolation or as part of an unstable bi- or trimalleolar fracture configuration. Traditional teaching recommends open reduction and fixation of medial malleolar fractures that are part of an unstable injury. However, there is recent evidence to suggest that nonoperative management of well-reduced fractures may result in equivalent outcomes, but without the morbidity associated with surgery. This review gives an update on the relevant anatomy and classification systems for medial malleolar fractures and an overview of the current literature regarding their management, including surgical approaches and the choice of implants. Cite this article: Bone Joint J 2019;101-B:512–521


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 931 - 938
1 May 2021
Liu Y Lu H Xu H Xie W Chen X Fu Z Zhang D Jiang B

Aims. The morphology of medial malleolar fracture is highly variable and difficult to characterize without 3D reconstruction. There is also no universally accepeted classification system. Thus, we aimed to characterize fracture patterns of the medial malleolus and propose a classification scheme based on 3D CT reconstruction. Methods. We retrospectively reviewed 537 consecutive cases of ankle fractures involving the medial malleolus treated in our institution. 3D fracture maps were produced by superimposing all the fracture lines onto a standard template. We sliced fracture fragments and the standard template based on selected sagittal and coronal planes to create 2D fracture maps, where angles α and β were measured. Angles α and β were defined as the acute angles formed by the fracture line and the horizontal line on the selected planes. Results. A total of 121 ankle fractures were included. We revealed several important fracture features, such as a high correlation between posterior collicular fractures and posteromedial fragments. Moreover, we generalized the fracture geometry into three recurrent patterns on the coronal view of 3D maps (transverse, vertical, and irregular) and five recurrent patterns on the lateral view (transverse, oblique, vertical, Y-shaped, and irregular). According to the fracture geometry on the coronal and lateral view of 3D maps, we subsequently categorized medial malleolar fractures into six types based on the recurrent patterns: anterior collicular fracture (27 type I, 22.3%), posterior collicular fracture (12 type II, 9.9%), concurrent fracture of anterior and posterior colliculus (16 type III, 13.2%), and supra-intercollicular groove fracture (66 type IV, 54.5%). Therewere three variants of type IV fractures: transverse (type IVa), vertical (type IVb), and comminuted fracture (type IVc). The angles α and β varied accordingly. Conclusion. Our findings yield insight into the characteristics and recurrent patterns of medial malleolar fractures. The proposed classification system is helpful in understanding injury mechanisms and guiding diagnosis, as well as surgical strategies. Cite this article: Bone Joint J 2021;103-B(5):931–938


Bone & Joint Open
Vol. 5, Issue 3 | Pages 227 - 235
18 Mar 2024
Su Y Wang Y Fang C Tu Y Chang C Kuan F Hsu K Shih C

Aims. The optimal management of posterior malleolar ankle fractures, a prevalent type of ankle trauma, is essential for improved prognosis. However, there remains a debate over the most effective surgical approach, particularly between screw and plate fixation methods. This study aims to investigate the differences in outcomes associated with these fixation techniques. Methods. We conducted a comprehensive review of clinical trials comparing anteroposterior (A-P) screws, posteroanterior (P-A) screws, and plate fixation. Two investigators validated the data sourced from multiple databases (MEDLINE, EMBASE, and Web of Science). Following PRISMA guidelines, we carried out a network meta-analysis (NMA) using visual analogue scale and American Orthopaedic Foot and Ankle Score (AOFAS) as primary outcomes. Secondary outcomes included range of motion limitations, radiological outcomes, and complication rates. Results. The NMA encompassed 13 studies, consisting of four randomized trials and eight retrospective ones. According to the surface under the cumulative ranking curve-based ranking, the A-P screw was ranked highest for improvements in AOFAS and exhibited lowest in infection and peroneal nerve injury incidence. The P-A screws, on the other hand, excelled in terms of VAS score improvements. Conversely, posterior buttress plate fixation showed the least incidence of osteoarthritis grade progression, postoperative articular step-off ≥ 2 mm, nonunions, and loss of ankle dorsiflexion ≥ 5°, though it underperformed in most other clinical outcomes. Conclusion. The NMA suggests that open plating is more likely to provide better radiological outcomes, while screw fixation may have a greater potential for superior functional and pain results. Nevertheless, clinicians should still consider the fragment size and fracture pattern, weighing the advantages of rigid biomechanical fixation against the possibility of soft-tissue damage, to optimize treatment results. Cite this article: Bone Jt Open 2024;5(3):227–235


Bone & Joint Open
Vol. 5, Issue 3 | Pages 252 - 259
28 Mar 2024
Syziu A Aamir J Mason LW

Aims. Posterior malleolar (PM) fractures are commonly associated with ankle fractures, pilon fractures, and to a lesser extent tibial shaft fractures. The tibialis posterior (TP) tendon entrapment is a rare complication associated with PM fractures. If undiagnosed, TP entrapment is associated with complications, ranging from reduced range of ankle movement to instability and pes planus deformities, which require further surgeries including radical treatments such as arthrodesis. Methods. The inclusion criteria applied in PubMed, Scopus, and Medline database searches were: all adult studies published between 2012 and 2022; and studies written in English. Outcome of TP entrapment in patients with ankle injuries was assessed by two reviewers independently. Results. Four retrospective studies and eight case reports were accepted in this systematic review. Collectively there were 489 Pilon fractures, 77 of which presented with TP entrapment (15.75%). There were 28 trimalleolar fractures, 12 of which presented with TP entrapment (42.86%). All the case report studies reported inability to reduce the fractures at initial presentation. The diagnosis of TP entrapment was made in the early period in two (25%) cases, and delayed diagnosis in six (75%) cases reported. Using modified Clavien-Dindo complication classification, 60 (67%) of the injuries reported grade IIIa complications and 29 (33%) grade IIIb complications. Conclusion. TP tendon was the commonest tendon injury associated with pilon fracture and, to a lesser extent, trimalleolar ankle fracture. Early identification using a clinical suspicion and CT imaging could lead to early management of TP entrapment in these injuries, which could lead to better patient outcomes and reduced morbidity. Cite this article: Bone Jt Open 2024;5(3):252–259


The Bone & Joint Journal
Vol. 95-B, Issue 12 | Pages 1662 - 1666
1 Dec 2013
Parker L Garlick N McCarthy I Grechenig S Grechenig W Smitham P

The AO Foundation advocates the use of partially threaded lag screws in the fixation of fractures of the medial malleolus. However, their threads often bypass the radiodense physeal scar of the distal tibia, possibly failing to obtain more secure purchase and better compression of the fracture. We therefore hypothesised that the partially threaded screws commonly used to fix a medial malleolar fracture often provide suboptimal compression as a result of bypassing the physeal scar, and proposed that better compression of the fracture may be achieved with shorter partially threaded screws or fully threaded screws whose threads engage the physeal scar. We analysed compression at the fracture site in human cadaver medial malleoli treated with either 30 mm or 45 mm long partially threaded screws or 45 mm fully threaded screws. The median compression at the fracture site achieved with 30 mm partially threaded screws (0.95 kg/cm. 2. (interquartile range (IQR) 0.8 to 1.2) and 45 mm fully threaded screws (1.0 kg/cm. 2 . (IQR 0.7 to 2.8)) was significantly higher than that achieved with 45 mm partially threaded screws (0.6 kg/cm. 2. (IQR 0.2 to 0.9)) (p = 0.04 and p < 0.001, respectively). The fully threaded screws and the 30mm partially threaded screws were seen to engage the physeal scar under an image intensifier in each case. The results support the use of 30 mm partially threaded or 45 mm fully threaded screws that engage the physeal scar rather than longer partially threaded screws that do not. A 45 mm fully threaded screw may in practice offer additional benefit over 30 mm partially threaded screws in increasing the thread count in the denser paraphyseal region. Cite this article: Bone Joint J 2013;95-B:1662–6


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 12 | Pages 1621 - 1625
1 Dec 2011
Donken CCMA Goorden AJF Verhofstad MHJ Edwards MJ van Laarhoven CJHM

We assessed the long-term (20 years) outcome of closed reduction and immobilisation in 19 patients with an isolated fracture of the posterior malleolus of the ankle treated at a single hospital between 1985 and 1990. The assessments used were an Olerud functional questionnaire score, physical examination using a loaded dorsal and plantar range of movement measurement, radiological analysis of medial joint space widening, the Cedell score for anatomical alignment of all three malleoli, and the radiological presence of osteoarthritic change. . There were excellent or good results in 14 patients (74%) according to the Olerud score, in 18 patients (95%) according to loaded dorsal and plantar range of movement assessment, in 16 patients (84%) as judged by the Cedell score, and for osteoarthritis 18 patients (95%) had an excellent or good score. There were no poor outcomes. There was no correlation between the size of the fracture gap and the proportion of the tibiotalar contact area when compared with the clinical results (gap size: rho values -0.16 to 0.04, p ≥ 0.51; tibiotalar contact area: rho values -0.20 to -0.03, p ≥ 0.4). Conservative treatment of ‘isolated’ posterior malleolar fractures resulted in good clinical and radiological outcome in this series at long-term follow-up.


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 4 | Pages 615 - 619
1 Aug 1987
Bostman O Vainionpaa S Hirvensalo E Makela A Vihtonen K Tormala P Rokkanen P

Fifty-six patients with displaced malleolar fractures had open reduction and fixation of the fracture fragments using, by random selection, either biodegradable implants or metal AO plates and screws. The cylindrical biodegradable implants were made of polylactide-glycolide copolymer (polyglactin 910). The complications, radiographic results and functional recovery were studied prospectively. After follow-up of at least one year, no significant differences emerged in the complication rate or in the results of treatment between the two methods of fixation. Because of the advantage of avoiding the need to remove metal fixation after union, we now use biodegradable internal fixation routinely to treat displaced malleolar fractures


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 3 | Pages 511 - 513
1 May 1991
Tonnesen H Pedersen A Jensen M Moller A Madsen J

The postoperative morbidity after osteosynthesis of malleolar fractures was investigated retrospectively by comparing 90 alcohol abusers with 90 controls. The two groups were selected from 626 male patients and were matched regarding trauma, treatment for cardiovascular, pulmonary and endocrine diseases, age, weight, smoking habits, anaesthesia and duration of surgery. The alcohol abusers developed significantly more early complications, especially infections, after surgery. Follow-up at six, nine and 12 weeks after surgery also revealed a significantly higher morbidity among the alcoholics


The Bone & Joint Journal
Vol. 98-B, Issue 6 | Pages 812 - 817
1 Jun 2016
Verhage SM Boot F Schipper IB Hoogendoorn JM

Aims

Involvement of the posterior malleolus in fractures of the ankle probably adversely affects the functional outcome and may be associated with the development of post-traumatic osteoarthritis. Anatomical reduction is a predictor of a successful outcome.

The purpose of this study was to describe the technique and short-term outcome of patients with trimalleolar fractures, who were treated surgically using a posterolateral approach in our hospital between 2010 and 2014.

Patients and Methods

The study involved 52 patients. Their mean age was 49 years (22 to 79). There were 41 (79%) AO 44B-type and 11 (21%) 44C-type fractures. The mean size of the posterior fragment was 27% (10% to 52%) of the tibiotalar joint surface.


The Bone & Joint Journal
Vol. 102-B, Issue 9 | Pages 1229 - 1241
14 Sep 2020
Blom RP Hayat B Al-Dirini RMA Sierevelt I Kerkhoffs GMMJ Goslings JC Jaarsma RL Doornberg JN

Aims. The primary aim of this study was to address the hypothesis that fracture morphology might be more important than posterior malleolar fragment size in rotational type posterior malleolar ankle fractures (PMAFs). The secondary aim was to identify clinically important predictors of outcome for each respective PMAF-type, to challenge the current dogma that surgical decision-making should be based on fragment size. Methods. This observational prospective cohort study included 70 patients with operatively treated rotational type PMAFs, respectively: 23 Haraguchi Type I (large posterolateral-oblique), 22 Type II (two-part posterolateral and posteromedial), and 25 (avulsion-) Type III. There was no standardized protocol on how to address the PMAFs and CT-imaging was used to classify fracture morphology and quality of postoperative syndesmotic reduction. Quantitative 3D-CT (Q3DCT) was used to assess the quality of fracture reduction, respectively: the proportion of articular involvement; residual intra-articular: gap, step-off, and 3D-displacement; and residual gap and step-off at the fibular notch. These predictors were correlated with the Foot and Ankle Outcome Score (FAOS) at two-years follow-up. Results. Bivariate analyses revealed that fracture morphology (p = 0.039) as well as fragment size (p = 0.007) were significantly associated with the FAOS. However, in multivariate analyses, fracture morphology (p = 0.001) (but not fragment size (p = 0.432)) and the residual intra-articular gap(s) (p = 0.009) were significantly associated. Haraguchi Type-II PMAFs had poorer FAOS scores compared with Types I and III. Multivariate analyses identified the following independent predictors: step-off in Type I; none of the Q3DCT-measurements in Type II, and quality of syndesmotic reduction in small-avulsion Type III PMAFs. Conclusion. PMAFs are three separate entities based on fracture morphology, with different predictors of outcome for each PMAF type. The current debate on whether or not to fix PMAFs needs to be refined to determine which morphological subtype benefits from fixation. In PMAFs, fracture morphology should guide treatment instead of fragment size. Cite this article: Bone Joint J 2020;102-B(9):1229–1241


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1126 - 1131
1 Aug 2015
Nortunen S Flinkkilä T Lantto I Kortekangas T Niinimäki J Ohtonen P Pakarinen H

We prospectively assessed the diagnostic accuracy of the gravity stress test and clinical findings to evaluate the stability of the ankle mortise in patients with supination–external rotation-type fractures of the lateral malleolus without widening of the medial clear space. The cohort included 79 patients with a mean age of 44 years (16 to 82). Two surgeons assessed medial tenderness, swelling and ecchymosis and performed the external rotation (ER) stress test (a reference standard). A diagnostic radiographer performed the gravity stress test.

For the gravity stress test, the positive likelihood ratio (LR) was 5.80 with a 95% confidence interval (CI) of 2.75 to 12.27, and the negative LR was 0.15 (95% CI 0.07 to 0.35), suggesting a moderate change from the pre-test probability. Medial tenderness, both alone and in combination with swelling and/or ecchymosis, indicated a small change (positive LR, 2.74 to 3.25; negative LR, 0.38 to 0.47), whereas swelling and ecchymosis indicated only minimal changes (positive LR, 1.41 to 1.65; negative LR, 0.38 to 0.47).

In conclusion, when gravity stress test results are in agreement with clinical findings, the result is likely to predict stability of the ankle mortise with an accuracy equivalent to ER stress test results. When clinical examination suggests a medial-side injury, however, the gravity stress test may give a false negative result.

Cite this article: Bone Joint J 2015; 97-B:1126–31.


Bone & Joint Open
Vol. 3, Issue 10 | Pages 841 - 849
27 Oct 2022
Knight R Keene DJ Dutton SJ Handley R Willett K

Aims. The rationale for exacting restoration of skeletal anatomy after unstable ankle fracture is to improve outcomes by reducing complications from malunion; however, current definitions of malunion lack confirmatory clinical evidence. Methods. Radiological (absolute radiological measurements aided by computer software) and clinical (clinical interpretation of radiographs) definitions of malunion were compared within the Ankle Injury Management (AIM) trial cohort, including people aged ≥ 60 years with an unstable ankle fracture. Linear regressions were used to explore the relationship between radiological malunion (RM) at six months and changes in function at three years. Function was assessed with the Olerud-Molander Ankle Score (OMAS), with a minimal clinically important difference set as six points, as per the AIM trial. Piecewise linear models were used to investigate new radiological thresholds which better explain symptom impact on ankle function. Results. Previously described measures of RM and surgeon opinion of clinically significant malunion (CSM) were shown to be related but with important differences. CSM was more strongly related to outcome (-13.9 points on the OMAS; 95% confidence interval (CI) -21.9 to -5.4) than RM (-5.5 points; 95% CI -9.8 to -1.2). Existing malunion thresholds for talar tilt and tibiofibular clear space were shown to be slightly conservative; new thresholds which better explain function were identified (talar tilt > 2.4°; tibiofibular clear space > 6 mm). Based on this new definition the presence of RM had an impact on function, which was statistically significant, but the clinical significance was uncertain (-9.1 points; 95% CI -13.8 to -4.4). In subsequent analysis, RM of a posterior malleolar fracture was shown to have a statistically significant impact on OMAS change scores, but the clinical significance was uncertain (-11.6 points; 95% CI -21.9 to -0.6). Conclusion. These results provide clinical evidence which supports the previously accepted definitions. Further research to investigate more conservative clinical thresholds for malunion is indicated. Cite this article: Bone Jt Open 2022;3(10):841–849


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 696 - 703
1 Apr 2021
Clough TM Ring J

Aims. We report the medium-term outcomes of a consecutive series of 118 Zenith total ankle arthroplasties (TAAs) from a single, non-designer centre. Methods. Between December 2010 and May 2016, 118 consecutive Zenith prostheses were implanted in 114 patients. Demographic, clinical, and patient-reported outcome measures (PROMs) data were collected. The endpoint of the study was failure of the implant requiring revision of one or all of the components. Kaplan-Meier survival curves were generated with 95% confidence intervals (CIs) and the rate of failure calculated for each year. Results. Eight patients (ten ankles) died during follow-up, but none required revision. Of the surviving 106 patients (108 ankles: rheumatoid arthritis (RA), n = 15; osteoarthritis (OA), n = 93), 38 were women and 68 were men, with a mean age of 68.2 years (48 to 86) at the time of surgery. Mean follow-up was 5.1 years (2.1 to 9.0). A total of ten implants failed (8.5%), thus requiring revision. The implant survival at seven years, using revision as an endpoint, was 88.2% (95% CI 100% to 72.9%). There was a mean improvement in Manchester-Oxford Foot and Ankle Questionnaire (MOXFQ) from 85.0 to 32.8 and visual analogue scale (VAS) scores from 7.0 to 3.2, and overall satisfaction was 89%. The three commonest complications were malleolar fracture (14.4%, n = 17), wound healing (13.6%, n = 16), and superficial infection (12.7%, n = 15). The commonest reason for revision was aseptic loosening. No patients in our study were revised for deep infection. Conclusion. Our results show that Zenith survival rates are comparable with those in the literature for other implants and in the National Joint Registry (NJR). Overall patient satisfaction was high as were functional outcomes. However, the data highlight potential complications associated with this surgery. The authors believe that these figures support ankle arthroplasty as an option in the treatment of ankle arthritis. Cite this article: Bone Joint J 2021;103-B(4):696–703


The Bone & Joint Journal
Vol. 99-B, Issue 11 | Pages 1496 - 1501
1 Nov 2017
Bali N Aktselis I Ramasamy A Mitchell S Fenton P

Aims. There has been an evolution recently in the management of unstable fractures of the ankle with a trend towards direct fixation of a posterior malleolar fragment. Within these fractures, Haraguchi type 2 fractures extend medially and often cannot be fixed using a standard posterolateral approach. Our aim was to describe the posteromedial approach to address these fractures and to assess its efficacy and safety. Patients and Methods. We performed a review of 15 patients with a Haraguchi type 2 posterior malleolar fracture which was fixed using a posteromedial approach. Five patients underwent initial temporary spanning external fixation. The outcome was assessed at a median follow-up of 29 months (interquartile range (IQR) 17 to 36) using the Olerud and Molander score and radiographs were assessed for the quality of the reduction. Results. The median Olerud and Molander score was 72 (IQR 70 to 75), representing a good functional outcome. The reduction was anatomical in ten, with a median step of 1.2 mm (IQR 0.9 to 1.85) in the remaining five patients. One patient had parasthaesiae affecting the medial forefoot, which resolved within three months. Conclusion. We found that the posteromedial approach to the ankle for the surgical treatment of Haraguchi type 2 posterior malleolar fractures is a safe technique that enables good visualisation and reduction of the individual fracture fragments with promising early outcomes. Cite this article: Bone Joint J 2017;99-B:1496–1501


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 3 | Pages 435 - 438
1 May 1995
Chissell H Jones J

We performed a retrospective study of the factors affecting the outcome of Weber type-C ankle fractures in 43 patients reviewed at two to nine years after injury. We determined the functional result in relation to the use of a diastasis screw, the accuracy of reduction, the presence of tibiotalar dislocation, and of injury to the medial side of the ankle by medial malleolar fracture or deltoid ligament rupture. We assessed the use of a diastasis screw as appropriate or inappropriate on the basis of an anatomical study performed by Boden et al (1989). The diastasis screw was used unnecessarily in 19 of the 31 patients so treated, but this did not appear to affect the final functional result. The worse functional results were in ankles dislocated at the initial injury, and in those with medial malleolar fractures as opposed to those with deltoid ligament ruptures. The best results were after accurate reduction of the fibula and the syndesmosis, and greater increase in the width of the syndesmosis was associated with a worse result. Our results suggest that an increase of more than 1.5 mm in syndesmosis width is unacceptable. We recommend that when the deltoid ligament is ruptured, a diastasis screw should be used if the fibular fracture is more than 3.5 cm above the top of the syndesmosis. When a medial malleolar fracture has been rigidly repaired a diastasis screw is required if the fibular fracture is more than 15 cm above the syndesmosis


Bone & Joint 360
Vol. 1, Issue 2 | Pages 25 - 27
1 Apr 2012

The April 2012 Trauma Roundup. 360 . looks at fibula-pro-tibia plating, galeazzi fractures, distal radial fractures in the over 65s, transverse sacral fractures, acute dislocation of the knee, posterior malleolar fractures, immobilising the broken scaphoid, the terrible triad, lower limb amputation after trauma, and whiplash injuries


Bone & Joint 360
Vol. 4, Issue 4 | Pages 18 - 20
1 Aug 2015

The August 2015 Foot & Ankle Roundup. 360 . looks at: Is orthosis more important than physio in tibialis posterior deficiency?; Radiographic evaluation of ankle injury; Sciatic catheter quite enough!; A fresh look at avascular necrosis of the talus; Total ankle and VTE; Outcomes of posterior malleolar fracture; Absorbable sutures in the Achilles tendon; Lisfranc injuries under the spotlight


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 12 | Pages 1607 - 1611
1 Dec 2009
Stufkens SAS Knupp M Lampert C van Dijk CN Hintermann B

We have compared the results at a mean follow-up of 13 years (11 to 14) of two groups of supination-external rotation type-4 fractures of the ankle, in one of which there was a fracture of the medial malleolus and in the other the medial deltoid ligament had been partially or completely ruptured. Of 66 patients treated operatively between 1993 and 1997, 36 were available for follow-up. Arthroscopy had been performed in all patients pre-operatively to assess the extent of the intra-articular lesions. The American Orthopaedic Foot and Ankle Society hind-foot score was used for clinical evaluation and showed a significant difference in both the total and the functional scores (p < 0.05), but not in those for pain or alignment, in favour of the group with a damaged deltoid ligament (p < 0.05). The only significant difference between the groups on the short-form 36 quality-of-life score was for bodily pain, again in favour of the group with a damaged deltoid ligament. There was no significant difference between the groups in the subjective visual analogue scores or in the modified Kannus radiological score. Arthroscopically, there was a significant difference with an increased risk of loose bodies in the group with an intact deltoid ligament (p < 0.005), although there was no significant increased risk of deep cartilage lesions in the two groups. At a mean follow-up of 13 years after operative treatment of a supination-external rotation type-4 ankle fracture patients with partial or complete rupture of the medial deltoid ligament tended to have a better result than those with a medial malleolar fracture


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 1008 - 1014
1 Sep 2024
Prijs J Rawat J ten Duis K Assink N Harbers JS Doornberg JN Jadav B Jaarsma RL IJpma FFA

Aims

Paediatric triplane fractures and adult trimalleolar ankle fractures both arise from a supination external rotation injury. By relating the experience of adult to paediatric fractures, clarification has been sought on the sequence of injury, ligament involvement, and fracture pattern of triplane fractures. This study explores the similarities between triplane and trimalleolar fractures for each stage of the Lauge-Hansen classification, with the aim of aiding reduction and fixation techniques.

Methods

Imaging data of 83 paediatric patients with triplane fractures and 100 adult patients with trimalleolar fractures were collected, and their fracture morphology was compared using fracture maps. Visual fracture maps were assessed, classified, and compared with each other, to establish the progression of injury according to the Lauge-Hansen classification.


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 72 - 81
1 Jan 2023
Stake IK Ræder BW Gregersen MG Molund M Wang J Madsen JE Husebye EE

Aims

The aim of this study was to compare the functional and radiological outcomes and the complication rate after nail and plate fixation of unstable fractures of the ankle in elderly patients.

Methods

In this multicentre study, 120 patients aged ≥ 60 years with an acute unstable AO/OTA type 44-B fracture of the ankle were randomized to fixation with either a nail or a plate and followed for 24 months after surgery. The primary outcome measure was the American Orthopaedic Foot and Ankle Society (AOFAS) Ankle-Hindfoot score. Secondary outcome measures were the Manchester-Oxford Foot Questionnaire, the Olerud and Molander Ankle score, the EuroQol five-dimension questionnaire, a visual analogue score for pain, complications, the quality of reduction of the fracture, nonunion, and the development of osteoarthritis.


Bone & Joint 360
Vol. 13, Issue 3 | Pages 37 - 40
3 Jun 2024

The June 2024 Trauma Roundup360 looks at: Skin antisepsis before surgical fixation of limb fractures; Comparative analysis of intramedullary nail versus plate fixation for fibula fracture in supination external rotation type IV ankle injury; Early weightbearing versus late weightbearing after intramedullary nailing for distal femoral fracture (AO/OTA 33) in elderly patients: a multicentre propensity-matched study; Long-term outcomes with spinal versus general anaesthesia for hip fracture surgery; Operative versus nonoperative management of unstable medial malleolus fractures: a randomized clinical trial; Impact of smoking status on fracture-related infection characteristics and outcomes; Reassessing empirical antimicrobial choices in fracture-related infections; Development and validation of the Nottingham Trauma Frailty Index (NTFI) for older trauma patients.


Bone & Joint 360
Vol. 12, Issue 3 | Pages 8 - 9
1 Jun 2023
Stringer H


The Bone & Joint Journal
Vol. 105-B, Issue 11 | Pages 1226 - 1232
1 Nov 2023
Prijs J Rawat J ten Duis K IJpma FFA Doornberg JN Jadav B Jaarsma RL

Aims

Triplane ankle fractures are complex injuries typically occurring in children aged between 12 and 15 years. Classic teaching that closure of the physis dictates the overall fracture pattern, based on studies in the 1960s, has not been challenged. The aim of this paper is to analyze whether these injuries correlate with the advancing closure of the physis with age.

Methods

A fracture mapping study was performed in 83 paediatric patients with a triplane ankle fracture treated in three trauma centres between January 2010 and June 2020. Patients aged younger than 18 years who had CT scans available were included. An independent Paediatric Orthopaedic Trauma Surgeon assessed all CT scans and classified the injuries as n-part triplane fractures. Qualitative analysis of the fracture pattern was performed using the modified Cole fracture mapping technique. The maps were assessed for both patterns and correlation with the closing of the physis until consensus was reached by a panel of six surgeons.


Bone & Joint Open
Vol. 5, Issue 1 | Pages 9 - 19
16 Jan 2024
Dijkstra H van de Kuit A de Groot TM Canta O Groot OQ Oosterhoff JH Doornberg JN

Aims

Machine-learning (ML) prediction models in orthopaedic trauma hold great promise in assisting clinicians in various tasks, such as personalized risk stratification. However, an overview of current applications and critical appraisal to peer-reviewed guidelines is lacking. The objectives of this study are to 1) provide an overview of current ML prediction models in orthopaedic trauma; 2) evaluate the completeness of reporting following the Transparent Reporting of a multivariable prediction model for Individual Prognosis Or Diagnosis (TRIPOD) statement; and 3) assess the risk of bias following the Prediction model Risk Of Bias Assessment Tool (PROBAST) tool.

Methods

A systematic search screening 3,252 studies identified 45 ML-based prediction models in orthopaedic trauma up to January 2023. The TRIPOD statement assessed transparent reporting and the PROBAST tool the risk of bias.


The Journal of Bone & Joint Surgery British Volume
Vol. 56-B, Issue 3 | Pages 508 - 512
1 Aug 1974
Miller AJ

1. A method of treatment of posterior malleolar fracture is described which restores the proximal surface of the ankle joint to its normal position. 2. Reduction is achieved with a special clamp and the position held with a strong plate. Early ankle movements may therefore be encouraged without fear of redisplacing the fracture. 3. Perfect reduction is necessary to avoid the later onset of arthritis, and this was achieved in five of six patients reported


Bone & Joint 360
Vol. 12, Issue 3 | Pages 18 - 22
1 Jun 2023

The June 2023 Foot & Ankle Roundup360 looks at: Nail versus plate fixation for ankle fractures; Outcomes of first ray amputation in diabetic patients; Vascular calcification on plain radiographs of the ankle to diagnose diabetes mellitus; Elderly patients with ankle fracture: the case for early weight-bearing; Active treatment for Frieberg’s disease: does it work?; Survival of ankle arthroplasty; Complications following ankle arthroscopy.


Bone & Joint 360
Vol. 12, Issue 2 | Pages 19 - 24
1 Apr 2023

The April 2023 Foot & Ankle Roundup360 looks at: Outcomes following a two-stage revision total ankle arthroplasty for periprosthetic joint infection; Temporary bridge plate fixation and joint motion after an unstable Lisfranc injury; Outcomes of fusion in type II os naviculare; Total ankle arthroplasty versus arthrodesis for end-stage ankle osteoarthritis; Normal saline for plantar fasciitis: placebo or therapeutic?; Distraction arthroplasty for ankle osteoarthritis: does it work?; Let there be movement: ankle arthroplasty after previous fusion; Morbidity and mortality after diabetic Charcot foot arthropathy.


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 4 | Pages 679 - 682
1 Jul 1991
Bostman O

We analysed the radiographs of 67 patients with displaced malleolar fractures treated by open reduction and internal fixation using absorbable polyglycolide rods. Seventeen patients developed a discharging inflammatory foreign-body reaction, a complication unique to these fixation devices. In 34 patients ovoid osteolytic foci, usually 5 to 10 mm in diameter, appeared within the implant channels six to 12 weeks after the operation. The same lesion occurred in 14 of the 17 patients who developed a foreign-body reaction, whereas only 20 out of the 50 patients with an uneventful course showed osteolytic areas (p less than 0.01). In patients with a foreign-body reaction the osteolytic foci tended to occur in the deepest parts of the implant channels. However, after one year the normal structure of the bone was restored


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 4 | Pages 689 - 692
1 Jul 1998
McCormack RG Leith JM

To determine the relative risk of complications in treating ankle fractures in patients with diabetes, we compared the results of the management of displaced malleolar fractures in 26 patients with those of a matched group of non-diabetic patients, using a case-controlled study. The groups were matched for patient age, fracture type and treating surgeon. The incidence of significant complications in diabetic patients was 42.3%. By contrast, there were no complications in the matched group of non-diabetic patients. Of 19 diabetic patients treated surgically, six developed major complications including one case of malunion, one of necrosis of the wound edge requiring a flap, and two of deep sepsis. Two patients required amputation and both died. Diabetic patients with displaced ankle fractures treated non-operatively had a high incidence of loss of reduction and malunion but these caused few symptoms. In these patients, non-operative management may be preferable in view of the high risks of major complications after surgery and the acceptance of malunion by the older patient with lower demands


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 2 | Pages 333 - 338
1 Mar 1998
Böstman OM

Between 1985 and 1994, 1223 patients with malleolar fractures of the ankle were treated by open reduction and internal fixation with absorbable pins and screws, of whom 74 (6.1%) had an obvious inflammatory foreign-body reaction to the implants. Of these 74, ten later developed moderate to severe osteoarthritis of the ankle despite no evidence of incongruity of the articular surface. The implants used in these patients were made from polyglycolide, polylactide or glycolidelactide copolymer. The joint damage seemed to be due to polymeric debris entering the articular cavity through an osteolytic extension of an implant track. The ten patients had a long clinical course which included a vigorous local foreign-body reaction, synovial irritation and subsequent degeneration. At a follow-up of three to nine years, ankle arthrodesis had been necessary in two patients and is being considered for another two. The incidence of these changes in the whole series was 0.8%, which is not high, but awareness of this possible late complication is essential


Bone & Joint 360
Vol. 10, Issue 5 | Pages 21 - 24
1 Oct 2021


Bone & Joint 360
Vol. 11, Issue 4 | Pages 32 - 35
1 Aug 2022


Bone & Joint 360
Vol. 10, Issue 4 | Pages 22 - 27
1 Aug 2021


Bone & Joint Research
Vol. 9, Issue 8 | Pages 477 - 483
1 Aug 2020
Holweg P Herber V Ornig M Hohenberger G Donohue N Puchwein P Leithner A Seibert F

Aims

This study is a prospective, non-randomized trial for the treatment of fractures of the medial malleolus using lean, bioabsorbable, rare-earth element (REE)-free, magnesium (Mg)-based biodegradable screws in the adult skeleton.

Methods

A total of 20 patients with isolated, bimalleolar, or trimalleolar ankle fractures were recruited between July 2018 and October 2019. Fracture reduction was achieved through bioabsorbable Mg-based screws composed of pure Mg alloyed with zinc (Zn) and calcium (Ca) ( Mg-Zn0.45-Ca0.45, in wt.%; ZX00). Visual analogue scale (VAS) and the presence of complications (adverse events) during follow-up (12 weeks) were used to evaluate the clinical outcomes. The functional outcomes were analyzed through the range of motion (ROM) of the ankle joint and the American Orthopaedic Foot and Ankle Society (AOFAS) score. Fracture reduction and gas formation were assessed using several plane radiographs.


Bone & Joint 360
Vol. 10, Issue 5 | Pages 43 - 45
1 Oct 2021


The Bone & Joint Journal
Vol. 103-B, Issue 7 | Pages 1270 - 1276
1 Jul 2021
Townshend DN Bing AJF Clough TM Sharpe IT Goldberg A

Aims

This is a multicentre, non-inventor, prospective observational study of 503 INFINITY fixed bearing total ankle arthroplasties (TAAs). We report our early experience, complications, and radiological and functional outcomes.

Methods

Patients were recruited from 11 specialist centres between June 2016 and November 2019. Demographic, radiological, and functional outcome data (Ankle Osteoarthritis Scale, Manchester Oxford Questionnaire, and EuroQol five-dimension five-level score) were collected preoperatively, at six months, one year, and two years. The Canadian Orthopaedic Foot and Ankle Society (COFAS) grading system was used to stratify deformity. Early and late complications and reoperations were recorded as adverse events. Radiographs were assessed for lucencies, cysts, and/or subsidence.


The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 212 - 219
1 Feb 2020
Ræder BW Figved W Madsen JE Frihagen F Jacobsen SB Andersen MR

Aims

In a randomized controlled trial with two-year follow-up, patients treated with suture button (SB) for acute syndesmotic injury had better outcomes than patients treated with syndesmotic screw (SS). The aim of this study was to compare clinical and radiological outcomes for these treatment groups after five years.

Methods

A total of 97 patients with acute syndesmotic injury were randomized to SS or SB. The five-year follow-up rate was 81 patients (84%). The primary outcome was the American Orthopaedic Foot and Ankle Society (AOFAS) Ankle Hindfoot Scale. Secondary outcome measures included Olerud-Molander Ankle (OMA) score, visual analogue scale (VAS), EuroQol five-dimension questionnaire (EQ-5D), range of movement, complications, reoperations, and radiological results. CT scans of both ankles were obtained after surgery, and after one, two, and five years.


Bone & Joint Open
Vol. 2, Issue 7 | Pages 503 - 508
8 Jul 2021
Callaghan CJ McKinley JC

Aims

Arthroplasty has become increasingly popular to treat end-stage ankle arthritis. Iatrogenic posterior neurovascular and tendinous injury have been described from saw cuts. However, it is hypothesized that posterior ankle structures could be damaged by inserting tibial guide pins too deeply and be a potential cause of residual hindfoot pain.

Methods

The preparation steps for ankle arthroplasty were performed using the Infinity total ankle system in five right-sided cadaveric ankles. All tibial guide pins were intentionally inserted past the posterior tibial cortex for assessment. All posterior ankles were subsequently dissected, with the primary endpoint being the presence of direct contact between the structure and pin.


Bone & Joint 360
Vol. 9, Issue 4 | Pages 37 - 39
1 Aug 2020


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 746 - 754
1 Apr 2021
Schnetzke M El Barbari J Schüler S Swartman B Keil H Vetter S Gruetzner PA Franke J

Aims

Complex joint fractures of the lower extremity are often accompanied by soft-tissue swelling and are associated with prolonged hospitalization and soft-tissue complications. The aim of the study was to evaluate the effect of vascular impulse technology (VIT) on soft-tissue conditioning in comparison with conventional elevation.

Methods

A total of 100 patients were included in this prospective, randomized, controlled monocentre study allocated to the three subgroups of dislocated ankle fracture (n = 40), pilon fracture (n = 20), and intra-articular calcaneal fracture (n = 40). Patients were randomized to the two study groups in a 1:1 ratio. The effectiveness of VIT (intervention) compared with elevation (control) was analyzed separately for the whole study population and for the three subgroups. The primary endpoint was the time from admission until operability (in days).


Bone & Joint 360
Vol. 9, Issue 6 | Pages 22 - 27
1 Dec 2020


The Bone & Joint Journal
Vol. 100-B, Issue 10 | Pages 1352 - 1358
1 Oct 2018
Clough TM Alvi F Majeed H

Aims

Total ankle arthroplasty (TAA) surgery is complex and attracts a wide variety of complications. The literature lacks consistency in reporting adverse events and complications. The aim of this article is to provide a comprehensive analysis of each of these complications from a literature review, and to compare them with rates from our Unit, to aid clinicians with the process of informed consent.

Patients and Methods

A total of 278 consecutive total ankle arthroplasties (251 patients), performed by four surgeons over a six-year period in Wrightington Hospital (Wigan, United Kingdom) were prospectively reviewed. There were 143 men and 108 women with a mean age of 64 years (41 to 86). The data were recorded on each follow-up visit. Any complications either during initial hospital stay or subsequently reported on follow-ups were recorded, investigated, monitored, and treated as warranted. Literature search included the studies reporting the outcomes and complications of TAA implants.


Bone & Joint 360
Vol. 7, Issue 6 | Pages 31 - 33
1 Dec 2018


Bone & Joint 360
Vol. 8, Issue 1 | Pages 31 - 33
1 Feb 2019


Bone & Joint 360
Vol. 7, Issue 4 | Pages 3 - 8
1 Aug 2018
White TO Carter TH


Bone & Joint 360
Vol. 7, Issue 2 | Pages 18 - 20
1 Apr 2018


The Bone & Joint Journal
Vol. 100-B, Issue 5 | Pages 566 - 569
1 May 2018
White TO

The posterior malleolus of the ankle is the object of increasing attention, with considerable enthusiasm for CT scanning and surgical fixation, as expressed in a recent annotation in The Bone & Joint Journal. Undoubtedly, fractures with a large posterior malleolar fragment that allow posterior talar subluxation from the mortise are served better by fixation. However, in all other situations, the existing literature does not support this widespread change in practice. The available biomechanical evidence shows that the posterior malleolus has little part to play in the stability or contact stresses of the ankle joint. Radiographic studies have not shown that CT scanning offers helpful information on pathoanatomical classification, case selection, or prognosis, or that scanning improves the likelihood of an adequate surgical reduction. Clinical studies have not shown any improvement in patient outcome after surgical fixation, and have confirmed that the inevitable consequence of increased intervention is an increased rate of complications. A careful and thoughtful evaluation of indications, risks, and benefits of this fashionable concept is required to ensure that we are deploying valuable resources with efficacy, and that we do no harm.

Cite this article: Bone Joint J 2018;100-B:566–9.


Bone & Joint 360
Vol. 8, Issue 5 | Pages 21 - 24
1 Oct 2019


Bone & Joint 360
Vol. 8, Issue 4 | Pages 34 - 36
1 Aug 2019