Advertisement for orthosearch.org.uk
Results 1 - 50 of 105
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 6 | Pages 976 - 977
1 Nov 1995
Orfaly R Keating J O'Brien P


The Bone & Joint Journal
Vol. 96-B, Issue 2 | Pages 249 - 253
1 Feb 2014
Euler SA Hengg C Kolp D Wambacher M Kralinger F

Antegrade nailing of proximal humeral fractures using a straight nail can damage the bony insertion of the supraspinatus tendon and may lead to varus failure of the construct. In order to establish the ideal anatomical landmarks for insertion of the nail and their clinical relevance we analysed CT scans of bilateral proximal humeri in 200 patients (mean age 45.1 years (. sd. 19.6; 18 to 97) without humeral fractures. The entry point of the nail was defined by the point of intersection of the anteroposterior and lateral vertical axes with the cortex of the humeral head. The critical point was defined as the intersection of the sagittal axis with the medial limit of the insertion of the supraspinatus tendon on the greater tuberosity. The region of interest, i.e. the biggest entry hole that would not encroach on the insertion of the supraspinatus tendon, was calculated setting a 3 mm minimal distance from the critical point. This identified that 38.5% of the humeral heads were categorised as ‘critical types’, due to morphology in which the predicted offset of the entry point would encroach on the insertion of the supraspinatus tendon that may damage the tendon and reduce the stability of fixation. We therefore emphasise the need for ‘fastidious’ pre-operative planning to minimise this risk. Cite this article: Bone Joint J 2014;96-B:249–53


The Bone & Joint Journal
Vol. 98-B, Issue 8 | Pages 1080 - 1085
1 Aug 2016
Gauci MO Boileau P Baba M Chaoui J Walch G

Aims. Patient-specific glenoid guides (PSGs) claim an improvement in accuracy and reproducibility of the positioning of components in total shoulder arthroplasty (TSA). The results have not yet been confirmed in a prospective clinical trial. Our aim was to assess whether the use of PSGs in patients with osteoarthritis of the shoulder would allow accurate and reliable implantation of the glenoid component. Patients and Methods. A total of 17 patients (three men and 14 women) with a mean age of 71 years (53 to 81) awaiting TSA were enrolled in the study. Pre- and post-operative version and inclination of the glenoid were measured on CT scans, using 3D planning automatic software. During surgery, a congruent 3D-printed PSG was applied onto the glenoid surface, thus determining the entry point and orientation of the central guide wire used for reaming the glenoid and the introduction of the component. Manual segmentation was performed on post-operative CT scans to compare the planned and the actual position of the entry point (mm) and orientation of the component (°). Results. The mean error in the accuracy of the entry point was -0.1 mm (standard deviation (. sd. ) 1.4) in the horizontal plane, and 0.8 mm (. sd. 1.3) in the vertical plane. The mean error in the orientation of the glenoid component was 3.4° (. sd. 5.1°) for version and 1.8° (. sd. 5.3°) for inclination. Conclusion. Pre-operative planning with automatic software and the use of PSGs provides accurate and reproducible positioning and orientation of the glenoid component in anatomical TSA. Cite this article: Bone Joint J 2016;98-B:1080–5


The Bone & Joint Journal
Vol. 100-B, Issue 8 | Pages 1054 - 1059
1 Aug 2018
Kelly C Harwood PJ Loughenbury PR Clancy JA Britten S

Aims. Anatomical atlases document classical safe corridors for the placement of transosseous fine wires through the calcaneum during circular frame external fixation. During this process, the posterior tibial neurovascular bundle (PTNVB) is placed at risk, though this has not been previously quantified. We describe a cadaveric study to investigate a safe technique for posterolateral to anteromedial fine wire insertion through the body of the calcaneum. Materials and Methods. A total of 20 embalmed cadaveric lower limbs were divided into two groups. Wires were inserted using two possible insertion points and at varying angles. In Group A, wires were inserted one-third along a line between the point of the heel and the tip of the lateral malleolus while in Group B, wires were inserted halfway along this line. Standard dissection techniques identified the structures at risk and the distance of wires from neurovascular structures was measured. The results from 19 limbs were subject to analysis. Results. In Group A, no wires pierced the PTNVB. Wires were inserted a median 22.3 mm (range 4.7 to 39.6) from the PTNVB; two wires (4%) passed within 5 mm. In Group B, 24 (46%) wires passed within 5 mm of the PTNVB, with 11 wires piercing it. The median distance of wires from the PTNVB was 5.5 mm (range 0 to 30). A Mann–Whitney U test showed that this was significantly closer than in Group A (Hodges–Lehmann shift, 14.06 mm; 95% confidence interval (CI) 10.52 to 16.88; p < 0.0001). In Group B, with an increased angle of insertion there was greater risk to the PTNVB (r. s.  = -0.80; p < 0.01). Conclusion. Insertion of wires using an entry point one-third along a line from the point of the heel to the tip of the lateral malleolus (Group A) appears to be the safer technique. An insertion angle of up to 30° to the coronal plane can be used without significant risk to the PTNVB. Insertion of wires halfway along a line from the point of the heel to the tip of the lateral malleolus (Group B) carried a significantly higher risk of injury to neurovascular structures and, if necessary, an angle of insertion parallel to the coronal plane should be used. Cite this article: Bone Joint J 2018;100-B:1054–9


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1499 - 1505
1 Nov 2012
Kim J Kasat NS Bae J Kim S Oh S Lim H

The purpose of this study was to measure the radiological parameters of femoral component alignment of the Oxford Phase 3 unicompartmental knee replacement (UKR), and evaluate their effect on clinical outcome. Multiple regression analysis was used to examine the relative contributions of the radiological assessment of femoral component alignment in 189 consecutive UKRs performed by a single surgeon. The American Knee Society scores were compared between groups, defined as being within or outside recommended tolerances of the position of the femoral component. For the flexion/extension position 21 UKRs (11.1%) lay outside the recommended limits, and for posterior overhang of the femoral component nine (4.8%) lay outside the range. The pre-operative hip/knee/ankle (HKA) angle, narrowest canal distance from the distal femoral entry point of the alignment jig and coronal entry-point position had significant effects on the flexion/extension position. Pre-operative HKA angle had a significant influence on posterior overhang of the femoral component. However, there was no significant difference in American Knee Society scores relative to the position of the femoral component


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 1 | Pages 33 - 41
1 Jan 2000
Hernigou P Cohen D

The risk of articular penetration during tibial nailing is well known, but the incidence of unrecognised damage to joint cartilage has not been described. We have identified this complication in the treatment of tibial fractures, described the anatomical structures at risk and examined the most appropriate site of entry for tibial nailing in relation to the shape of the bone, the design of the nail and the surgical approach. We studied the relationship between the intra-articular structures of the knee and the entry point used for nailing in 54 tibiae from cadavers. The results showed that the safe zone in some bones is smaller than the size of standard reamers and the proximal part of some nails. The structures at risk are the anterior horns of the medial and lateral menisci, the anterior part of the medial and lateral plateaux and the ligamentum transversum. This was confirmed by observations made after nailing 12 pairs of cadaver knees. A retrospective radiological analysis of 30 patients who had undergone tibial nailing identified eight at risk according to the entry point and the size of the nail. Unrecognised articular penetration and damage during surgery were confirmed in four. Although intramedullary nailing has been shown to be a successful method for treating fractures of the tibia, one of the most common problems after bony union is pain in the knee. Unrecognised intra-articular injury of the knee may be one cause of this


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 2 | Pages 239 - 243
1 Mar 2004
Cutler L Molloy A Dhukuram V Bass A

Distal tibial physeal fractures are the second most common growth plate injury and the most common cause of growth arrest and deformity. This study assesses the accuracy of pre-operative planning for placement of the screws in these fractures using either standard radiographs or CT scans. We studied 62 consecutive physeal fractures over a period of four years. An outline of a single cut of the CT scan was used for each patient. An ideal position for the screw was determined as being perpendicular to and at the midpoint of the fracture. The difference in entry point and direction of the screw between the ideal and the observers’ assessments were compared using the paired Student’s t-test. There was a statistically significant improvement (p < 0.0001) in the accuracy of the point of insertion and the direction of the screw on the pre-operative plan when CT scans were used rather than plain radiographs. We would, therefore, recommend that CT scans are routinely used in the pre-operative assessment and treatment of distal tibial physeal fractures


Bone & Joint Open
Vol. 5, Issue 2 | Pages 101 - 108
6 Feb 2024
Jang SJ Kunze KN Casey JC Steele JR Mayman DJ Jerabek SA Sculco PK Vigdorchik JM

Aims

Distal femoral resection in conventional total knee arthroplasty (TKA) utilizes an intramedullary guide to determine coronal alignment, commonly planned for 5° of valgus. However, a standard 5° resection angle may contribute to malalignment in patients with variability in the femoral anatomical and mechanical axis angle. The purpose of the study was to leverage deep learning (DL) to measure the femoral mechanical-anatomical axis angle (FMAA) in a heterogeneous cohort.

Methods

Patients with full-limb radiographs from the Osteoarthritis Initiative were included. A DL workflow was created to measure the FMAA and validated against human measurements. To reflect potential intramedullary guide placement during manual TKA, two different FMAAs were calculated either using a line approximating the entire diaphyseal shaft, and a line connecting the apex of the femoral intercondylar sulcus to the centre of the diaphysis. The proportion of FMAAs outside a range of 5.0° (SD 2.0°) was calculated for both definitions, and FMAA was compared using univariate analyses across sex, BMI, knee alignment, and femur length.


Bone & Joint Open
Vol. 5, Issue 1 | Pages 46 - 52
19 Jan 2024
Assink N ten Duis K de Vries JPM Witjes MJH Kraeima J Doornberg JN IJpma FFA

Aims

Proper preoperative planning benefits fracture reduction, fixation, and stability in tibial plateau fracture surgery. We developed and clinically implemented a novel workflow for 3D surgical planning including patient-specific drilling guides in tibial plateau fracture surgery.

Methods

A prospective feasibility study was performed in which consecutive tibial plateau fracture patients were treated with 3D surgical planning, including patient-specific drilling guides applied to standard off-the-shelf plates. A postoperative CT scan was obtained to assess whether the screw directions, screw lengths, and plate position were performed according the preoperative planning. Quality of the fracture reduction was assessed by measuring residual intra-articular incongruence (maximum gap and step-off) and compared to a historical matched control group.


Bone & Joint Research
Vol. 11, Issue 3 | Pages 180 - 188
1 Mar 2022
Rajpura A Asle SG Ait Si Selmi T Board T

Aims

Hip arthroplasty aims to accurately recreate joint biomechanics. Considerable attention has been paid to vertical and horizontal offset, but femoral head centre in the anteroposterior (AP) plane has received little attention. This study investigates the accuracy of restoration of joint centre of rotation in the AP plane.

Methods

Postoperative CT scans of 40 patients who underwent unilateral uncemented total hip arthroplasty were analyzed. Anteroposterior offset (APO) and femoral anteversion were measured on both the operated and non-operated sides. Sagittal tilt of the femoral stem was also measured. APO measured on axial slices was defined as the perpendicular distance between a line drawn from the anterior most point of the proximal femur (anterior reference line) to the centre of the femoral head. The anterior reference line was made parallel to the posterior condylar axis of the knee to correct for rotation.


Bone & Joint 360
Vol. 12, Issue 2 | Pages 34 - 36
1 Apr 2023

The April 2023 Trauma Roundup360 looks at: Displaced femoral neck fractures in patients aged 55 to 70 years: internal fixation or total hip arthroplasty?; Tibial plateau fractures: continuous passive motion approves range of motion; Lisfranc fractures: to fuse or not to fuse, that is the question; Is hardware removal after clavicle fracture plate fixation beneficial?; Fixation to coverage in Grade IIIB open fractures – what’s the time window?; Nonoperative versus locking plate fixation in the proximal humerus; Retrograde knee nailing or lateral plate for distal femur fractures?


Bone & Joint Open
Vol. 5, Issue 9 | Pages 809 - 817
27 Sep 2024
Altorfer FCS Kelly MJ Avrumova F Burkhard MD Sneag DB Chazen JL Tan ET Lebl DR

Aims

To report the development of the technique for minimally invasive lumbar decompression using robotic-assisted navigation.

Methods

Robotic planning software was used to map out bone removal for a laminar decompression after registration of CT scan images of one cadaveric specimen. A specialized acorn-shaped bone removal robotic drill was used to complete a robotic lumbar laminectomy. Post-procedure advanced imaging was obtained to compare actual bony decompression to the surgical plan. After confirming accuracy of the technique, a minimally invasive robotic-assisted laminectomy was performed on one 72-year-old female patient with lumbar spinal stenosis. Postoperative advanced imaging was obtained to confirm the decompression.


Bone & Joint 360
Vol. 12, Issue 6 | Pages 42 - 45
1 Dec 2023

The December 2023 Children’s orthopaedics Roundup360 looks at: A comprehensive nonoperative treatment protocol for developmental dysplasia of the hip in infants; How common are refractures in childhood?; Femoral nailing for paediatric femoral shaft fracture in children aged eight to ten years; Who benefits from allowing the physis to grow in slipped capital femoral epiphysis?; Paediatric patients with an extremity bone tumour: a secondary analysis of the PARITY trial data; Split tibial tendon transfers in cerebral palsy equinovarus foot deformities; Liposomal bupivacaine nerve block: an answer to opioid use?; Correction with distal femoral transphyseal screws in hemiepiphysiodesis for coronal-plane knee deformity.


Bone & Joint Open
Vol. 4, Issue 9 | Pages 682 - 688
6 Sep 2023
Hampton M Balachandar V Charalambous CP Sutton PM

Aims

Aseptic loosening is the most common cause of failure following cemented total knee arthroplasty (TKA), and has been linked to poor cementation technique. We aimed to develop a consensus on the optimal technique for component cementation in TKA.

Methods

A UK-based, three-round, online modified Delphi Expert Consensus Study was completed focusing on cementation technique in TKA. Experts were identified as having a minimum of five years’ consultant experience in the NHS and fulfilling any one of the following criteria: a ‘high volume’ knee arthroplasty practice (> 150 TKAs per annum) as identified from the National joint Registry of England, Wales, Northern Ireland and the Isle of Man; a senior author of at least five peer reviewed articles related to TKA in the previous five years; a surgeon who is named trainer for a post-certificate of comletion of training fellowship in TKA.


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 593 - 601
1 Jun 2023
Scott CEH Yapp LZ Howard T Patton JT Moran M

Periprosthetic femoral fractures are increasing in incidence, and typically occur in frail elderly patients. They are similar to pathological fractures in many ways. The aims of treatment are the same, including 'getting it right first time' with a single operation, which allows immediate unrestricted weightbearing, with a low risk of complications, and one that avoids the creation of stress risers locally that may predispose to further peri-implant fracture. The surgical approach to these fractures, the associated soft-tissue handling, and exposure of the fracture are key elements in minimizing the high rate of complications. This annotation describes the approaches to the femur that can be used to facilitate the surgical management of peri- and interprosthetic fractures of the femur at all levels using either modern methods of fixation or revision arthroplasty.

Cite this article: Bone Joint J 2023;105-B(6):593–601.


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 72 - 81
1 Jan 2023
Stake IK Ræder BW Gregersen MG Molund M Wang J Madsen JE Husebye EE

Aims

The aim of this study was to compare the functional and radiological outcomes and the complication rate after nail and plate fixation of unstable fractures of the ankle in elderly patients.

Methods

In this multicentre study, 120 patients aged ≥ 60 years with an acute unstable AO/OTA type 44-B fracture of the ankle were randomized to fixation with either a nail or a plate and followed for 24 months after surgery. The primary outcome measure was the American Orthopaedic Foot and Ankle Society (AOFAS) Ankle-Hindfoot score. Secondary outcome measures were the Manchester-Oxford Foot Questionnaire, the Olerud and Molander Ankle score, the EuroQol five-dimension questionnaire, a visual analogue score for pain, complications, the quality of reduction of the fracture, nonunion, and the development of osteoarthritis.


The Bone & Joint Journal
Vol. 104-B, Issue 2 | Pages 290 - 296
1 Feb 2022
Gosheger G Ahrens H Dreher P Schneider KN Deventer N Budny T Heitkötter B Schulze M Theil C

Aims

Iliosacral sarcoma resections have been shown to have high rates of local recurrence (LR) and poor overall survival. There is also no universal classification for the resection of pelvic sarcomas invading the sacrum. This study proposes a novel classification system and analyzes the survival and risk of recurrence, when using this system.

Methods

This is a retrospective analysis of 151 patients (with median follow-up in survivors of 44 months (interquartile range 12 to 77)) who underwent hemipelvectomy with iliosacral resection at a single centre between 2007 and 2019. The proposed classification differentiates the extent of iliosacral resection and defines types S1 to S6 (S1 resection medial and parallel to the sacroiliac joint, S2 resection through the ipsilateral sacral lateral mass to the neuroforamina, S3 resection through the ipsilateral neuroforamina, S4 resection through ipsilateral the spinal canal, and S5 and S6 contralateral sacral resections). Descriptive statistics and the chi-squared test were used for categorical variables, and the Kaplan-Meier survival analysis were performed.


Bone & Joint 360
Vol. 10, Issue 1 | Pages 33 - 37
1 Feb 2021


Bone & Joint 360
Vol. 10, Issue 5 | Pages 24 - 28
1 Oct 2021


The Bone & Joint Journal
Vol. 103-B, Issue 7 Supple B | Pages 33 - 37
1 Jul 2021
Ennin KA Elsharkawy KA Dasgupta S Emerson RH

Aims

To achieve the functional benefits of the direct anterior (DA) approach and the fixation benefits of cemented replacement, this study combined the two techniques posing the following questions: does the limited access of the DA approach adversely affect the cement technique?; and does such a cementing technique reduce the incidence of cementless complications?

Methods

A consecutive series of 341 patients (360 hips) receiving the DA approach between 2016 and 2018 were reviewed. There were 203 cementless stems and 157 cemented stems. Mean age was 75 years (70 to 86) in the cementless group and 76 years (52 to 94) in the cemented group, with 239 (70%) females in the whole series. Femoral complications were compared between the two groups. Mean follow-up was 1.5 years (0.1 to 4.4) for patients in the cementless group and 1.3 years (0.0 to 3.9) for patients in the cemented group.


The Bone & Joint Journal
Vol. 102-B, Issue 3 | Pages 371 - 375
1 Mar 2020
Cawley D Dhokia R Sales J Darwish N Molloy S

With the identification of literature shortfalls on the techniques employed in intraoperative navigated (ION) spinal surgery, we outline a number of measures which have been synthesised into a coherent operative technique. These include positioning, dissection, management of the reference frame, the grip, the angle of attack, the drill, the template, the pedicle screw, the wire, and navigated intrathecal analgesia. Optimizing techniques to improve accuracy allow an overall reduction of the repetition of the surgical steps with its associated productivity benefits including time, cost, radiation, and safety.

Cite this article: Bone Joint J 2020;102-B(3):371–375.


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 36 - 42
1 Jun 2020
Nishitani K Kuriyama S Nakamura S Umatani N Ito H Matsuda S

Aims

This study aimed to evaluate the association between the sagittal alignment of the femoral component in total knee arthroplasty (TKA) and new Knee Society Score (2011KSS), under the hypothesis that outliers such as the excessive extended or flexed femoral component were related to worse clinical outcomes.

Methods

A group of 156 knees (134 F:22 M) in 133 patients with a mean age 75.8 years (SD 6.4) who underwent TKA with the cruciate-substituting Bi-Surface Knee prosthesis were retrospectively enrolled. On lateral radiographs, γ angle (the angle between the distal femoral axis and the line perpendicular to the distal rear surface of the femoral component) was measured, and the patients were divided into four groups according to the γ angle. The 2011KSSs among groups were compared using the Kruskal-Wallis test. A secondary regression analysis was used to investigate the association between the 2011KSS and γ angle.


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 294 - 298
1 Feb 2021
Hadeed MM Prakash H Yarboro SR Weiss DB

Aims

The aim of this study was to determine the immediate post-fixation stability of a distal tibial fracture fixed with an intramedullary nail using a biomechanical model. This was used as a surrogate for immediate weight-bearing postoperatively. The goal was to help inform postoperative protocols.

Methods

A biomechanical model of distal metaphyseal tibial fractures was created using a fourth-generation composite bone model. Three fracture patterns were tested: spiral, oblique, and multifragmented. Each fracture extended to within 4 cm to 5 cm of the plafond. The models were nearly-anatomically reduced and stabilized with an intramedullary nail and three distal locking screws. Cyclic loading was performed to simulate normal gait. Loading was completed in compression at 3,000 N at 1 Hz for a total of 70,000 cycles. Displacement (shortening, coronal and sagittal angulation) was measured at regular intervals.


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 415 - 420
1 Feb 2021
Farr S Jauker F Ganger R Kranzl A

Aims

The aims of this study is to report the clinical and radiological outcomes after pre-, central-, and postaxial polydactyly resection in children from a tertiary referral centre.

Methods

All children who underwent resection of a supernumerary toe between 2001 and 2013 were prospectively enrolled and invited for a single re-assessment. Clinical parameters and several dedicated outcome scores (visual analogue scale (VAS), Paediatric Outcomes Data Collection Instrument (PODCI), Activities Scale for Kids (ASK), and American Orthopaedic Foot and Ankle Society Score (AOFAS)) were obtained, as were radiographs of the operated and non-operated feet along with pedobarographs.


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 321 - 328
1 Feb 2021
Vandeputte F Vanbiervliet J Sarac C Driesen R Corten K

Aims

Optimal exposure through the direct anterior approach (DAA) for total hip arthroplasty (THA) conducted on a regular operating theatre table is achieved with a standardized capsular releasing sequence in which the anterior capsule can be preserved or resected. We hypothesized that clinical outcomes and implant positioning would not be different in case a capsular sparing (CS) technique would be compared to capsular resection (CR).

Methods

In this prospective trial, 219 hips in 190 patients were randomized to either the CS (n = 104) or CR (n = 115) cohort. In the CS cohort, a medial based anterior flap was created and sutured back in place at the end of the procedure. The anterior capsule was resected in the CR cohort. Primary outcome was defined as the difference in patient-reported outcome measures (PROMs) after one year. PROMs (Harris Hip Score (HHS), Hip disability and Osteoarthritis Outcome Score (HOOS), and Short Form 36 Item Health Survey (SF-36)) were collected preoperatively and one year postoperatively. Radiological parameters were analyzed to assess implant positioning and implant ingrowth. Adverse events were monitored.


The Bone & Joint Journal
Vol. 103-B, Issue 1 | Pages 123 - 130
1 Jan 2021
Lapner P Pollock JW Laneuville O Uhthoff HK Zhang T Sheikh A McIlquham K Trudel G

Aims

Despite recent advances in arthroscopic rotator cuff repair, re-tear rates remain high. New methods to improve healing rates following rotator cuff repair must be sought. Our primary objective was to determine if adjunctive bone marrow stimulation with channelling five to seven days prior to arthroscopic cuff repair would lead to higher Western Ontario Rotator Cuff (WORC) scores at 24 months postoperatively compared with no channelling.

Methods

A prospective, randomized controlled trial was conducted in patients undergoing arthroscopic rotator cuff repair. Patients were randomized to receive either a percutaneous bone channelling of the rotator cuff footprint or a sham procedure under ultrasound guidance five to seven days prior to index surgery. Outcome measures included the WORC, American Shoulder and Elbow Surgeons (ASES), and Constant scores, strength, ultrasound-determined healing rates, and adverse events.


The Bone & Joint Journal
Vol. 101-B, Issue 12 | Pages 1479 - 1488
1 Dec 2019
Laverdière C Corban J Khoury J Ge SM Schupbach J Harvey EJ Reindl R Martineau PA

Aims

Computer-based applications are increasingly being used by orthopaedic surgeons in their clinical practice. With the integration of technology in surgery, augmented reality (AR) may become an important tool for surgeons in the future. By superimposing a digital image on a user’s view of the physical world, this technology shows great promise in orthopaedics. The aim of this review is to investigate the current and potential uses of AR in orthopaedics.

Materials and Methods

A systematic review of the PubMed, MEDLINE, and Embase databases up to January 2019 using the keywords ‘orthopaedic’ OR ‘orthopedic AND augmented reality’ was performed by two independent reviewers.


The Bone & Joint Journal
Vol. 101-B, Issue 2 | Pages 178 - 188
1 Feb 2019
Chaudhary MM Lakhani PH

Aims

Double-level lengthening, bone transport, and bifocal compression-distraction are commonly undertaken using Ilizarov or other fixators. We performed double-level fixator-assisted nailing, mainly for the correction of deformity and lengthening in the same segment, using a straight intramedullary nail to reduce the time in a fixator.

Patients and Methods

A total of 23 patients underwent this surgery, involving 27 segments (23 femora and four tibiae), over a period of ten years. The most common indication was polio in ten segments and rickets in eight; 20 nails were inserted retrograde and seven antegrade. A total of 15 lengthenings were performed in 11 femora and four tibiae, and 12 double-level corrections of deformity without lengthening were performed in the femur. The mean follow-up was 4.9 years (1.1 to 11.4). Four patients with polio had tibial lengthening with arthrodesis of the ankle. We compared the length of time in a fixator and the external fixation index (EFI) with a control group of 27 patients (27 segments) who had double-level procedures with external fixation. The groups were matched for the gain in length, age, and level of difficulty score.


Bone & Joint 360
Vol. 8, Issue 5 | Pages 33 - 35
1 Oct 2019


Bone & Joint 360
Vol. 9, Issue 3 | Pages 11 - 14
1 Jun 2020


The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 232 - 238
1 Feb 2020
Javed S Hadi S Imam MA Gerogiannis D Foden P Monga P

Aims

Accurate measurement of the glenoid version is important in performing total shoulder arthroplasty (TSA). Our aim was to evaluate the Ellipse method, which involves formally defining the vertical mid-point of the glenoid prior to measuring the glenoid version and comparing it with the ‘classic’ Friedman method.

Methods

This was a retrospective study which evaluated 100 CT scans for patients who underwent a primary TSA. The glenoid version was measured using the Friedman and Ellipse methods by two senior observers. Statistical analyses were performed using the paired t-test for significance and the Bland-Altman plot for agreement.


Bone & Joint 360
Vol. 8, Issue 6 | Pages 36 - 39
1 Dec 2019


Bone & Joint 360
Vol. 8, Issue 4 | Pages 32 - 34
1 Aug 2019


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1263 - 1271
1 Oct 2019
Eisenschenk A Spitzmüller R Güthoff C Obladen A Kim S Henning E Dornberger JE Stengel D

Aims

The aim of this study was to investigate whether clinical and radiological outcomes after intramedullary nailing of displaced fractures of the fifth metacarpal neck using a single thick Kirschner wire (K-wire) are noninferior to those of technically more demanding fixation with two thinner dual wires.

Patients and Methods

This was a multicentre, parallel group, randomized controlled noninferiority trial conducted at 12 tertiary trauma centres in Germany. A total of 290 patients with acute displaced fractures of the fifth metacarpal neck were randomized to either intramedullary single-wire (n = 146) or dual-wire fixation (n = 144). The primary outcome was the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire six months after surgery, with a third of the minimal clinically important difference (MCID) used as the noninferiority threshold. Secondary outcomes were pain, health-related quality of life (EuroQol five-dimensional questionnaire (EQ-5D)), radiological measures, functional deficits, and complications.


The Bone & Joint Journal
Vol. 101-B, Issue 9 | Pages 1168 - 1176
1 Sep 2019
Calder PR McKay JE Timms AJ Roskrow T Fugazzotto S Edel P Goodier WD

Aims

The Precice intramedullary limb-lengthening system has demonstrated significant benefits over external fixation lengthening methods, leading to a paradigm shift in limb lengthening. This study compares outcomes following antegrade and retrograde femoral lengthening in both adolescent and adult patients.

Patients and Methods

A retrospective review of prospectively collected data was undertaken of a consecutive series of 107 femoral lengthening operations in 92 patients. In total, 73 antegrade nails and 34 retrograde nails were inserted. Outcome was assessed by the regenerate healing index (HI), hip and knee range of movement (ROM), and the presence of any complications.


The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 610 - 614
1 May 2019
Aibinder WR Bartels DW Sperling JW Sanchez-Sotelo J

Aims

Shoulder arthroplasty using short humeral components is becoming increasingly popular. Some such components have been associated with relatively high rates of adverse radiological findings. The aim of this retrospective review was to evaluate the radiological humeral bone changes and mechanical failure rates with implantation of a short cementless humeral component in anatomical (TSA) and reverse shoulder arthroplasty (RSA).

Patients and Methods

A total of 100 shoulder arthroplasties (35 TSA and 65 RSA) were evaluated at a mean of 3.8 years (3 to 8.3). The mean age at the time of surgery was 68 years (31 to 90). The mean body mass index was 32.7 kg/m2 (17.3 to 66.4).


The Bone & Joint Journal
Vol. 99-B, Issue 9 | Pages 1232 - 1236
1 Sep 2017
Dahill M McArthur J Roberts GL Acharya MR Ward AJ Chesser TJS

Aims

The anterior pelvic internal fixator is increasingly used for the treatment of unstable, or displaced, injuries of the anterior pelvic ring. The evidence for its use, however, is limited. The aim of this paper is to describe the indications for its use, how it is applied and its complications.

Patients and Methods

We reviewed the case notes and radiographs of 50 patients treated with an anterior pelvic internal fixator between April 2010 and December 2015 at a major trauma centre in the United Kingdom. The median follow-up time was 38 months (interquartile range 24 to 51).


The Bone & Joint Journal
Vol. 99-B, Issue 8 | Pages 1095 - 1101
1 Aug 2017
Fuglesang HFS Flugsrud GB Randsborg PH Oord P Benth JŠ Utvåg SE

Aims

This is a prospective randomised controlled trial comparing the functional outcomes of plate fixation and elastic stable intramedullary nailing (ESIN) of completely displaced mid-shaft fractures of the clavicle in the active adult population.

Patients and Methods

We prospectively recruited 123 patients and randomised them to either plate fixation or ESIN. Patients completed the Quick Disabilities of the Arm, Shoulder and Hand (DASH) score at one to six weeks post-operatively. They were followed up at six weeks, three and six months and one year with radiographs, and their clinical outcome was assessed using both the DASH and the Constant Score.


The Bone & Joint Journal
Vol. 97-B, Issue 11 | Pages 1555 - 1561
1 Nov 2015
Kwan MK Chiu CK Lee CK Chan CYW

Percutaneous placement of pedicle screws is a well-established technique, however, no studies have compared percutaneous and open placement of screws in the thoracic spine. The aim of this cadaveric study was to compare the accuracy and safety of these techniques at the thoracic spinal level. A total of 288 screws were inserted in 16 (eight cadavers, 144 screws in percutaneous and eight cadavers, 144 screws in open). Pedicle perforations and fractures were documented subsequent to wide laminectomy followed by skeletalisation of the vertebrae. The perforations were classified as grade 0: no perforation, grade 1: < 2 mm perforation, grade 2: 2 mm to 4 mm perforation and grade 3: > 4 mm perforation. In the percutaneous group, the perforation rate was 11.1% with 15 (10.4%) grade 1 and one (0.7%) grade 2 perforations. In the open group, the perforation rate was 8.3% (12 screws) and all were grade 1. This difference was not significant (p = 0.45). There were 19 (13.2%) pedicle fractures in the percutaneous group and 21 (14.6%) in the open group (p = 0.73). In summary, the safety of percutaneous fluoroscopy-guided pedicle screw placement in the thoracic spine between T4 and T12 is similar to that of the conventional open technique.

Cite this article: Bone Joint J 2015;97-B:1555–61.


The Bone & Joint Journal
Vol. 99-B, Issue 3 | Pages 291 - 294
1 Mar 2017
Javaid MK Handley R Costa ML


The Bone & Joint Journal
Vol. 96-B, Issue 9 | Pages 1274 - 1281
1 Sep 2014
Farhang K Desai R Wilber JH Cooperman DR Liu RW

Malpositioning of the trochanteric entry point during the introduction of an intramedullary nail may cause iatrogenic fracture or malreduction. Although the optimal point of insertion in the coronal plane has been well described, positioning in the sagittal plane is poorly defined.

The paired femora from 374 cadavers were placed both in the anatomical position and in internal rotation to neutralise femoral anteversion. A marker was placed at the apparent apex of the greater trochanter, and the lateral and anterior offsets from the axis of the femoral shaft were measured on anteroposterior and lateral photographs. Greater trochanteric morphology and trochanteric overhang were graded.

The mean anterior offset of the apex of the trochanter relative to the axis of the femoral shaft was 5.1 mm (sd 4.0) and 4.6 mm (sd 4.2) for the anatomical and neutralised positions, respectively. The mean lateral offset of the apex was 7.1 mm (sd 4.6) and 6.4 mm (sd 4.6), respectively.

Placement of the entry position at the apex of the greater trochanter in the anteroposterior view does not reliably centre an intramedullary nail in the sagittal plane. Based on our findings, the site of insertion should be about 5 mm posterior to the apex of the trochanter to allow for its anterior offset.

Cite this article: Bone Joint J 2014;96-B:1274–81.


The Bone & Joint Journal
Vol. 100-B, Issue 2 | Pages 256 - 261
1 Feb 2018
Kim W Lee JS Chung HW

Aims

Adjuvant treatment after intralesional curettage for atypical cartilaginous tumours (ACTs) of long bones is widely accepted for extending surgical margins. However, evaluating the isolated effect of adjuvant treatment is difficult, and it is unclear whether not using such adjuvants provides poor oncological outcomes. Hence, we analyzed whether intralesional curettage without cryosurgery or chemical adjuvants provides poor oncological outcomes in patients with an ACT.

Patients and Methods

A total of 24 patients (nine men, 15 women) (mean age 45 years; 18 to 62) were treated for ACTs of long bones and followed up for a median of 66 months (interquartile range 50 to 84). All patients were treated with extensive manual curettage and limited burring. Bone cement and grafts were used to fill bone defects in 16 and eight patients, respectively. No chemical adjuvants or cryosurgery were used.


The Bone & Joint Journal
Vol. 95-B, Issue 7 | Pages 977 - 982
1 Jul 2013
Wu AM Tian NF Wu LJ He W Ni WF Wang XY Xu HZ Chi YL

The purpose of this study was to determine whether it would be feasible to use oblique lumbar interbody fixation for patients with degenerative lumbar disease who required a fusion but did not have a spondylolisthesis.

A series of CT digital images from 60 patients with abdominal disease were reconstructed in three dimensions (3D) using Mimics v10.01: a digital cylinder was superimposed on the reconstructed image to simulate the position of an interbody screw. The optimal entry point of the screw and measurements of its trajectory were recorded. Next, 26 cadaveric specimens were subjected to oblique lumbar interbody fixation on the basis of the measurements derived from the imaging studies. These were then compared with measurements derived directly from the cadaveric vertebrae.

Our study suggested that it is easy to insert the screws for L1/2, L2/3 and L3/4 fixation: there was no significant difference in measurements between those of the 3-D digital images and the cadaveric specimens. For L4/5 fixation, part of L5 inferior articular process had to be removed to achieve the optimal trajectory of the screw. For L5/S1 fixation, the screw heads were blocked by iliac bone: consequently, the interior oblique angle of the cadaveric specimens was less than that seen in the 3D digital images.

We suggest that CT scans should be carried out pre-operatively if this procedure is to be adopted in clinical practice. This will assist in determining the feasibility of the procedure and will provide accurate information to assist introduction of the screws.

Cite this article: Bone Joint J 2013;95-B:977–82.


The Bone & Joint Journal
Vol. 98-B, Issue 8 | Pages 1099 - 1105
1 Aug 2016
Weiser L Dreimann M Huber G Sellenschloh K Püschel K Morlock MM Rueger JM Lehmann W

Aims

Loosening of pedicle screws is a major complication of posterior spinal stabilisation, especially in the osteoporotic spine. Our aim was to evaluate the effect of cement augmentation compared with extended dorsal instrumentation on the stability of posterior spinal fixation.

Materials and Methods

A total of 12 osteoporotic human cadaveric spines (T11-L3) were randomised by bone mineral density into two groups and instrumented with pedicle screws: group I (SHORT) separated T12 or L2 and group II (EXTENDED) specimen consisting of T11/12 to L2/3. Screws were augmented with cement unilaterally in each vertebra. Fatigue testing was performed using a cranial-caudal sinusoidal, cyclic (1.0 Hz) load with stepwise increasing peak force.


The Bone & Joint Journal
Vol. 99-B, Issue 9 | Pages 1183 - 1189
1 Sep 2017
Cho BK Kim YM Choi SM Park HW SooHoo NF

Aims

The aim of this prospective study was to evaluate the intermediate-term outcomes after revision anatomical ankle ligament reconstruction augmented with suture tape for a failed modified Broström procedure.

Patients and Methods

A total of 30 patients with persistent instability of the ankle after a Broström procedure underwent revision augmented with suture tape. Of these, 24 patients who were followed up for more than two years were included in the study. There were 13 men and 11 women. Their mean age was 31.8 years (23 to 44). The mean follow-up was 38.5 months (24 to 56) The clinical outcome was assessed using the Foot and Ankle Outcome Score (FAOS) and the Foot and Ankle Ability Measure (FAAM) score. The stability of the ankle was assessed using stress radiographs.


Bone & Joint Research
Vol. 5, Issue 2 | Pages 46 - 51
1 Feb 2016
Du J Wu J Wen Z Lin X

Objectives

To employ a simple and fast method to evaluate those patients with neurological deficits and misplaced screws in relatively safe lumbosacral spine, and to determine if it is necessary to undertake revision surgery.

Methods

A total of 316 patients were treated by fixation of lumbar and lumbosacral transpedicle screws at our institution from January 2011 to December 2012. We designed the criteria for post-operative revision scores of pedicle screw malpositioning (PRSPSM) in the lumbosacral canal. We recommend the revision of the misplaced pedicle screw in patients with PRSPSM = 5′ as early as possible. However, patients with PRSPSM < 5′ need to follow the next consecutive assessment procedures. A total of 15 patients were included according to at least three-stage follow-up.


Bone & Joint 360
Vol. 6, Issue 2 | Pages 28 - 30
1 Apr 2017


Bone & Joint 360
Vol. 4, Issue 4 | Pages 31 - 33
1 Aug 2015

The August 2015 Children’s orthopaedics Roundup360 looks at: Learning the Pavlik; MRI and patellar instability; Cerebral palsy and hip dysplasia; ‘Pick your poison’: elastic nailing under the spotlight; Club feet and surgery; Donor site morbidity in vascularised fibular grafting; Cartilage biochemistry with hip dysplasia; SUFE and hip decompression: a good option?


The Bone & Joint Journal
Vol. 95-B, Issue 6 | Pages 764 - 769
1 Jun 2013
Roche JJW Jones CDS Khan RJK Yates PJ

The piriformis muscle is an important landmark in the surgical anatomy of the hip, particularly the posterior approach for total hip replacement (THR). Standard orthopaedic teaching dictates that the tendon must be cut in to allow adequate access to the superior part of the acetabulum and the femoral medullary canal. However, in our experience a routine THR can be performed through a posterior approach without sacrificing this tendon.

We dissected the proximal femora of 15 cadavers in order to clarify the morphological anatomy of the piriformis tendon. We confirmed that the tendon attaches on the crest of the greater trochanter, in a position superior to the trochanteric fossa, away from the entry point for broaching the intramedullary canal during THR. The tendon attachment site encompassed the summit and medial aspect of the greater trochanter as well as a variable attachment to the fibrous capsule of the hip joint. In addition we dissected seven cadavers resecting all posterior attachments except the piriformis muscle and tendon in order to study their relations to the hip joint, as the joint was flexed. At flexion of 90° the piriformis muscle lay directly posterior to the hip joint.

The piriform fossa is a term used by orthopaedic surgeons to refer the trochanteric fossa and normally has no relation to the attachment site of the piriformis tendon. In hip flexion the piriformis lies directly behind the hip joint and might reasonably be considered to contribute to the stability of the joint.

We conclude that the anatomy of the piriformis muscle is often inaccurately described in the current surgical literature and terms are used and interchanged inappropriately.

Cite this article: Bone Joint J 2013;95-B:764–9.


The Bone & Joint Journal
Vol. 97-B, Issue 9 | Pages 1204 - 1213
1 Sep 2015
Lazaro LE Klinger CE Sculco PK Helfet DL Lorich DG

This study investigates and defines the topographic anatomy of the medial femoral circumflex artery (MFCA) terminal branches supplying the femoral head (FH). Gross dissection of 14 fresh–frozen cadaveric hips was undertaken to determine the extra and intracapsular course of the MFCA’s terminal branches. A constant branch arising from the transverse MFCA (inferior retinacular artery; IRA) penetrates the capsule at the level of the anteroinferior neck, then courses obliquely within the fibrous prolongation of the capsule wall (inferior retinacula of Weitbrecht), elevated from the neck, to the posteroinferior femoral head–neck junction. This vessel has a mean of five (three to nine) terminal branches, of which the majority penetrate posteriorly. Branches from the ascending MFCA entered the femoral capsular attachment posteriorly, running deep to the synovium, through the neck, and terminating in two branches. The deep MFCA penetrates the posterosuperior femoral capsular. Once intracapsular, it divides into a mean of six (four to nine) terminal branches running deep to the synovium, within the superior retinacula of Weitbrecht of which 80% are posterior. Our study defines the exact anatomical location of the vessels, arising from the MFCA and supplying the FH. The IRA is in an elevated position from the femoral neck and may be protected from injury during fracture of the femoral neck. We present vascular ‘danger zones’ that may help avoid iatrogenic vascular injury during surgical interventions about the hip.

Cite this article: Bone Joint J 2015;97-B:1204–13.