We describe the technique and results of medial
submuscular
Aims. Dual
Aims. Surgical treatment of young femoral neck fractures often requires an open approach to achieve an anatomical reduction. The application of a calcar plate has recently been described to aid in femoral neck fracture reduction and to augment fixation. However, application of a plate may potentially compromise the regional vascularity of the femoral head and neck. The purpose of this study was to investigate the effect of calcar femoral neck
Aims. Posterior column
Aims. The purpose of this study was to compare reoperation and revision rates of double
Aims. The aim of this retrospective study was to compare the functional
and radiological outcomes of bridge
Using human cadaver specimens, we investigated
the role of supplementary fibular
Aims. The aim of this study was to investigate whether intraoperative 3D fluoroscopic imaging outperforms dorsal tangential views in the detection of dorsal cortex screw penetration after volar
Objectives. The Sliding Hip Screw (SHS) is commonly used to treat trochanteric hip fractures. Fixation failure is a devastating complication requiring complex revision surgery. One mode of fixation failure is lag screw cut-out which is greatest in unstable fracture patterns and when the tip-apex distance of the lag screw is > 25 mm. The X-Bolt Dynamic Hip
Aims. The aim of this study was to investigate the difference in functional outcome after repair and non-repair of the pronator quadratus muscle in patients undergoing surgical treatment for a distal radial fracture with volar
Permanent growth arrest of the longer bone is
an option in the treatment of minor leg-length discrepancies. The
use of a tension band
The aims of this study were to assess the efficacy
of a newly designed radiological technique (the radial groove view)
for the detection of protrusion of screws in the groove for the
extensor pollicis longus tendon (EPL) during
We performed a prospective, randomised trial to evaluate the outcome after surgery of displaced, unstable fractures of the distal radius. A total of 280 consecutive patients were enrolled in a prospective database and 88 identified who met the inclusion criteria for surgery. They were randomised to receive either bridging external fixation with supplementary Kirschner-wire fixation or volar-locked
Aims. We aimed to retrospectively assess the accuracy and safety of
CT navigated pedicle screws and to compare accuracy in the cervical
and thoracic spine (C2-T8) with (COMB) and without (POST) prior
anterior surgery (anterior cervical discectomy or corpectomy and
fusion with ventral
This study investigated the anatomical relationship between the clavicle and its adjacent vascular structures, in order to define safe zones, in terms of distance and direction, for drilling of the clavicle during osteosynthesis using a plate and screws following a fracture. We used reconstructed three-dimensional CT arteriograms of the head, neck and shoulder region. The results have enabled us to divide the clavicle into three zones based on the proximity and relationship of the vascular structures adjacent to it. The results show that at the medial end of the clavicle the subclavian vessels are situated behind it, with the vein intimately related to it. In some scans the vein was opposed to the posterior cortex of the clavicle. At the middle one-third of the clavicle the artery and vein are a mean of 17.02 mm (5.4 to 26.8) and 12.45 mm (5 to 26.1) from the clavicle, respectively, and at a mean angle of 50° (12 to 80) and 70° (38 to 100), respectively, to the horizontal. At the lateral end of the clavicle the artery and vein are at mean distances of 63.4 mm (46.8 to 96.5) and 75.67 mm (50 to 109), respectively. An appreciation of the information gathered from this study will help minimise the risk of inadvertent iatrogenic vascular injury during
Excellent results can be achieved by
Evaluate if treating an unstable femoral neck fracture with a locking plate and spring-loaded telescoping screw system would improve construct stability compared to gold standard treatment methods. A 31B2 Pauwels’ type III osteotomy with additional posterior wedge was cut into 30 fresh-frozen femur cadavers implanted with either: three cannulated screws in an inverted triangle configuration (CS), a sliding hip screw and anti-rotation screw (SHS), or a locking plate system with spring-loaded telescoping screws (LP). Dynamic cyclic compressive testing representative of walking with increasing weight-bearing was applied until failure was observed. Loss of fracture reduction was recorded using a high-resolution optical motion tracking system.Aims
Methods
This study tests the biomechanical properties of adjacent locked
plate constructs in a femur model using Sawbones. Previous studies
have described biomechanical behaviour related to inter-device distances.
We hypothesise that a smaller lateral inter-plate distance will
result in a biomechanically stronger construct, and that addition
of an anterior plate will increase the overall strength of the construct. Sawbones were plated laterally with two large-fragment locking
compression plates with inter-plate distances of 10 mm or 1 mm.
Small-fragment locking compression plates of 7-hole, 9-hole, and
11-hole sizes were placed anteriorly to span the inter-plate distance.
Four-point bend loading was applied, and the moment required to
displace the constructs by 10 mm was recorded.Objectives
Methods
Surgical treatment of hip fracture is challenging; the bone is porotic and fixation failure can be catastrophic. Novel implants are available which may yield superior clinical outcomes. This study compared the clinical effectiveness of the novel X-Bolt Hip System (XHS) with the sliding hip screw (SHS) for the treatment of fragility hip fractures. We conducted a multicentre, superiority, randomized controlled trial. Patients aged 60 years and older with a trochanteric hip fracture were recruited in ten acute UK NHS hospitals. Participants were randomly allocated to fixation of their fracture with XHS or SHS. A total of 1,128 participants were randomized with 564 participants allocated to each group. Participants and outcome assessors were blind to treatment allocation. The primary outcome was the EuroQol five-dimension five-level health status (EQ-5D-5L) utility at four months. The minimum clinically important difference in utility was pre-specified at 0.075. Secondary outcomes were EQ-5D-5L utility at 12 months, mortality, residential status, mobility, revision surgery, and radiological measures.Aims
Methods
Both conservative and operative forms of treatment
have been recommended for patients with a ‘floating shoulder’. We
compared the results of conservative and operative treatment in
25 patients with this injury and investigated the use of the glenopolar
angle (GPA) as an indicator of the functional outcome. A total of
13 patients (ten male and three female; mean age 32.5 years (24.7
to 40.4)) were treated conservatively and 12 patients (ten male
and two female; mean age 33.67 years (24.6 to 42.7)) were treated
operatively by fixation of the clavicular fracture alone. Outcome
was assessed using the Herscovici score, which was also related
to changes in the GPA at one year post-operatively. The mean Herscovici score was significantly better three months
and two years after the injury in the operative group (p <
0.001
and p = 0.003, respectively). There was a negative correlation between
the change in GPA and the Herscovici score at two years follow-up
in both the conservative and operative groups, but neither were
statistically significant
(r = -0.295 and r = -0.19, respectively). There was a significant
difference between the pre- and post-operative GPA in the operative
group (p = 0.017). When compared with conservative treatment, fixation of the clavicle
alone gives better results in the treatment of patients with a floating
shoulder. The GPA changes significantly with fixation of clavicle
alone but there is no significant correlation between the pre-injury
GPA and the final clinical outcome in these patients. Cite this article: