Advertisement for orthosearch.org.uk
Results 1 - 20 of 223
Results per page:

Aims. There are concerns regarding nail/medullary canal mismatch and initial stability after cephalomedullary nailing in unstable pertrochanteric fractures. This study aimed to investigate the effect of an additional anteroposterior blocking screw on fixation stability in unstable pertrochanteric fracture models with a nail/medullary canal mismatch after short cephalomedullary nail (CMN) fixation. Methods. Eight finite element models (FEMs), comprising four different femoral diameters, with and without blocking screws, were constructed, and unstable intertrochanteric fractures fixed with short CMNs were reproduced in all FEMs. Micromotions of distal shaft fragment related to proximal fragment, and stress concentrations at the nail construct were measured. Results. Micromotions in FEMs without a blocking screw significantly increased as nail/medullary canal mismatch increased, but were similar between FEMs with a blocking screw regardless of mismatch. Stress concentration at the nail construct was observed at the junction of the nail body and lag screw in all FEMs, and increased as nail/medullary canal mismatch increased, regardless of blocking screws. Mean stresses over regions of interest in FEMs with a blocking screw were much lower than regions of interest in those without. Mean stresses in FEMs with a blocking screw were lower than the yield strength, yet mean stresses in FEMs without blocking screws having 8 mm and 10 mm mismatch exceeded the yield strength. All mean stresses at distal locking screws were less than the yield strength. Conclusion. Using an additional anteroposterior blocking screw may be a simple and effective method to enhance fixation stability in unstable pertrochanteric fractures with a large nail/medullary canal mismatch due to osteoporosis. Cite this article: Bone Joint Res 2022;11(3):152–161


The Journal of Bone & Joint Surgery British Volume
Vol. 58-B, Issue 4 | Pages 444 - 447
1 Nov 1976
Newell R Durbin F

It is suggested that there is a group of cases of congenital angulation of tubular bones in which the lesion is a defect of ossification of the primary cartilaginous anlage and in which neurofibromatosis is not implicated. It appears that in this group the prognosis with regard to the resolution of deformity and the prevention of pseudarthrosis with conservative treatment or relatively simple surgical procedures is better than that in the neurofibromatous type.


The Bone & Joint Journal
Vol. 103-B, Issue 3 | Pages 530 - 535
1 Mar 2021
Giannicola G Castagna V Villani C Gumina S Scacchi M

Aims. It has been hypothesized that proximal radial neck resorption (PRNR) following press-fit radial head arthroplasty (RHA) is due to stress-shielding. We compared two different press-fit stems by means of radiographs to investigate whether the shape and size of the stems are correlated with the degree of PRNR. Methods. The radiographs of 52 RHAs were analyzed both at 14 days postoperatively and after two years. A cylindrical stem and a conical stem were implanted in 22 patients (group 1) and 30 patients (group 2), respectively. The PRNR was measured in the four quadrants of the radial neck and the degree of stem filling was calculated by analyzing the ratio between the prosthetic stem diameter (PSD) and the medullary canal diameter (MCD) at the proximal portion of the stem (level A), halfway along the stem length (level B), and distally at the stem tip (level C). Results. Overall, 50 of the 52 patients displayed PRNR. The mean PRNR observed was 3.9 mm (0 to 7.4). The degree of endomedullary stem filling at levels A, B, and C was 96%, 90%, and 68% in group 1, and 96%, 72%, and 57%, in group 2, with differences being significant at levels B (p < 0.001) and C (p < 0.001). No significant correlations emerged between the severity of PRNR and the three stem/canal ratios either within each group or between the groups. Conclusion. PRNR in press-fit RHA appears to be independent of the shape and size of the stems. Other causes besides stem design should be investigated to explain completely this phenomenon. Cite this article: Bone Joint J 2021;103-B(3):530–535


The Bone & Joint Journal
Vol. 102-B, Issue 8 | Pages 1082 - 1087
1 Aug 2020
Yiğit Ş Arslan H Akar MS Şahin MA

Aims. Osteopetrosis (OP) is a rare hereditary disease that causes reduced bone resorption and increased bone density as a result of osteoclastic function defect. Our aim is to review the difficulties, mid-term follow-up results, and literature encountered during the treatment of OP. Methods. This is a retrospective and observational study containing data from nine patients with a mean age of 14.1 years (9 to 25; three female, six male) with OP who were treated in our hospital between April 2008 and October 2018 with 20 surgical procedures due to 17 different fractures. Patient data included age, sex, operating time, length of stay, genetic type of the disease, previous surgery, fractures, complications, and comorbidity. Results. The mean follow-up period was 92.5 months (25 to 140). Bony union was observed in all of our patients. Osteomyelitis developed in two patients with femoral shaft fractures, and two patients had peri-implant stress fractures. Conclusion. Treatment of fractures in OP patients is difficult, healing is protracted, and the risk of postoperative infection is high. In children and young adults with OP who have open medullary canal and the epiphyses are not closed, fractures can be treated with surgical techniques such as intramedullary titanium elastic nail (TENS) technique or fixation with Kirschner (K)-wire. Cite this article: Bone Joint J 2020;102-B(8):1082–1087


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 7 | Pages 951 - 954
1 Jul 2006
Fenton PA Suvarna SK Currey JD Hamer AJ

Systemic mastocytosis is a rare condition that often involves the bone marrow. We report the case of a patient with systemic mastocytosis who underwent total hip replacement. Technical difficulties encountered during the procedure included a narrow medullary canal and abnormally hard bone, later confirmed by laboratory measurements. Follow-up at five years showed a good clinical and radiological outcome


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 5 | Pages 830 - 834
1 Sep 1990
Nather A Balasubramaniam P Bose K

Four different experiments were performed to study the healing of a large, non-vascularised, diaphyseal, bone segment in adult cats. In the first experiment, a 4 cm segment of tibia with its periosteum was excised and replaced in its bed. The other experiments were similar, except that in the second, the periosteum of the segment was removed, in the third its medullary canal was blocked with a Silastic rod, and in the last group the segment was isolated from its muscle bed by a Silastic sheet. The reparative processes were quantified by estimating the resorption index, the cortical new bone formation index, the callus encasement index, and the osteocyte count. Bone resorption and apposition occurred in the segment even when the periosteum was absent or the medullary canal was blocked, with osseous union at both ends by eight to 12 weeks, provided the segment was not isolated from its muscle bed. Thus, the muscle bed played a significant role in these reparative processes


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 11 | Pages 1515 - 1521
1 Nov 2010
Clauss M Ilchmann T Zimmermann P Ochsner PE

The aim of this study was to obtain detailed long-term data on the cement-bone interface in patients with cemented stems, implanted using the constrained fixation technique. A total of eight stems were removed together with adjacent bone during post-mortem examinations of patients with well-functioning prostheses. Specimens were cut at four defined levels, contact radiographs were obtained for each level, and slices were prepared for histological analysis. Clinical data, clinical radiographs, contact radiographs and histological samples were examined for signs of loosening and remodelling. The mean radiological follow-up was 9.6 years and all stems were well-fixed, based on clinical and radiological criteria. Contact radiographs revealed an incomplete cement mantle but a complete filling of the medullary canal for all implants. Various amounts of polyethylene particles were evident at the cement-bone interface of seven stems, with no accompanying inflammatory reaction. Cortical atrophy and the formation of an ‘inner cortex’ were confirmed in six of eight stems by contact radiographs and histology, but were only visible on two clinical radiographs. Our results confirm that a complete cement mantle is not essential for the survival of Müller straight stems into the mid term, and support our hypothesis that no benefit to long-term survival can be expected from modern cementing techniques


The Bone & Joint Journal
Vol. 95-B, Issue 6 | Pages 764 - 769
1 Jun 2013
Roche JJW Jones CDS Khan RJK Yates PJ

The piriformis muscle is an important landmark in the surgical anatomy of the hip, particularly the posterior approach for total hip replacement (THR). Standard orthopaedic teaching dictates that the tendon must be cut in to allow adequate access to the superior part of the acetabulum and the femoral medullary canal. However, in our experience a routine THR can be performed through a posterior approach without sacrificing this tendon. We dissected the proximal femora of 15 cadavers in order to clarify the morphological anatomy of the piriformis tendon. We confirmed that the tendon attaches on the crest of the greater trochanter, in a position superior to the trochanteric fossa, away from the entry point for broaching the intramedullary canal during THR. The tendon attachment site encompassed the summit and medial aspect of the greater trochanter as well as a variable attachment to the fibrous capsule of the hip joint. In addition we dissected seven cadavers resecting all posterior attachments except the piriformis muscle and tendon in order to study their relations to the hip joint, as the joint was flexed. At flexion of 90° the piriformis muscle lay directly posterior to the hip joint. The piriform fossa is a term used by orthopaedic surgeons to refer the trochanteric fossa and normally has no relation to the attachment site of the piriformis tendon. In hip flexion the piriformis lies directly behind the hip joint and might reasonably be considered to contribute to the stability of the joint. We conclude that the anatomy of the piriformis muscle is often inaccurately described in the current surgical literature and terms are used and interchanged inappropriately. Cite this article: Bone Joint J 2013;95-B:764–9


The Journal of Bone & Joint Surgery British Volume
Vol. 46-B, Issue 3 | Pages 518 - 529
1 Aug 1964
Charnley J

1. The use of acrylic cement in bonding femoral head prostheses to bone is described. 2. No sign of deterioration of the bond between the cement and bone has been seen in histological preparations up to three and a quarter years after operation, and no harmful effects have been recognised, or suspected, in 455 patients in whom it has been used. 3. The technique is considered justifiable in elderly patients where the medullary canal is large and the cortex of the femur is thin and brittle


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 1 | Pages 130 - 132
1 Jan 1992
Maffulli N Hughes T Fixsen J

Limb lengthening in nine patients was monitored by radiographs and by ultrasound scans. The distraction gap appeared as a sonolucent area within which echogenic foci developed soon after distraction commenced. By seven weeks a new cortex was detected, and medullary canal began to develop between seven and eight weeks. Ultrasound scanning can be used to measure distraction, but it was not as useful as radiographs in detecting angulation. Its use in patients undergoing limb lengthening could reduce their exposure to radiation


The Journal of Bone & Joint Surgery British Volume
Vol. 48-B, Issue 2 | Pages 333 - 335
1 May 1966
Giannikas AC

1. Three patients with enchondromata of the metacarpal bones are described. 2. The nature of the enchondromata in all three patients was confirmed by histological examination. 3. Treatment was by radical excision and bridging of the gap by a cortical bone graft. 4. There has been no impairment of function in the hands. No patient complained of pain after the operation. 5. Radiographs taken one year after operation in two patients showed that the flat bone grafts had become cylindrical and that medullary canals had appeared


The Journal of Bone & Joint Surgery British Volume
Vol. 65-B, Issue 5 | Pages 627 - 632
1 Nov 1983
Campanacci M Laus M Boriani S

Ten patients with multiple non-ossifying fibromata are reported. All had associated extraskeletal congenital anomalies such as cafe-au-lait spots, mental retardation, hypogonadism or cryptorchidism, ocular anomalies or cardiovascular malformations. The radiographic picture and the distribution of the skeletal lesions are characteristic and constant. There are lucent areas in the shaft with a sclerotic margin; these areas narrow the medullary canal or may completely fill it. It is suggested that these features characterise a new malformation syndrome, possibly allied to neurofibromatosis. After skeletal maturation is complete, the skeletal lesions may (like non-ossifying fibromata) regress and undergo spontaneous healing


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 5 | Pages 639 - 644
1 Nov 1984
Wroblewski B van der Rijt A

In order to improve the fixation of the stem in primary Charnley low-friction arthroplasty, the medullary canal was routinely closed off with a cancellous bone block. A prospective study of 611 consecutive arthroplasties were carried out between 1 and 5 1/2 years (average 2 years and 9 months) after operation. There were two cases of radiological loosening of the stem, both of which could have been avoided. Five other patients showed demarcation of the bone-cement junction at the calcar; two of these are considered to be "at risk" of loosening. There was no evidence of radiological loosening of the stem in 604 cases and the method is recommended for routine use in primary total hip arthroplasty


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 6 | Pages 972 - 974
1 Nov 1997
Milner SA

Accurate measurement of the alignment of the tibia is important both clinically and in research. The conventional method of measuring the angle of malunion after a fracture of the shaft of the tibia is potentially inaccurate because the mechanical axis of the normal bone may not pass down the centre of the medullary canal. An alternative method is described in which a radiograph of the opposite tibia is used as a template. A sample of 56 sets of standard radiographs of healed fractures of the shaft of the tibia was evaluated. The 95% limits of agreement between this and the conventional method were wide, being −6.2° to +5.5° for coronal angulation and −6.7° to +8.1° for sagittal angulation. These results suggest that the conventional method is inaccurate. The new method has good inter- and intraobserver reliability


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 3 | Pages 385 - 389
1 May 1992
Barrack R Mulroy R Harris W

To assess the effect of improved methods of femoral cementing on the loosening rates in young patients, we reviewed 50 'second-generation' cemented hip arthroplasties in 44 patients aged 50 years or less. The femoral stems were all collared and rectangular in cross-section with rounded corners. The cement was delivered by a gun into a medullary canal occluded distally with a cement plug. A clinical and radiographic review was undertaken at an average of 12 years (10 to 14.8) and no patient was lost to follow-up. No femoral component was revised for aseptic loosening, and only one stem was definitely loose by radiographic criteria. By contrast, 11 patients had undergone revision for symptomatic aseptic loosening of the acetabular component and 11 more had radiographic signs of acetabular loosening


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 4 | Pages 620 - 623
1 Jul 1998
Mohammed NSE

A new technique of shoulder fusion is presented using a posterior approach. After removal of the articular cartilage, a Rush pin is introduced from the spine of the scapula, through the glenoid into the medullary canal of the humerus. This is supplemented by tension-band wiring from the acromion to the neck of the humerus and a muscle pedicle graft attached to the acromion. A shoulder spica is applied for four to six weeks. Four patients with injuries to the upper brachial plexus and 14 with paralysis of the upper arm due to anterior poliomyelitis have been followed for three years. One of the 18 patients developed nonunion; she had removed her own cast prematurely. This method of fixation provides high shear resistance and low axial stiffness without deforming plastically. It does not affect bone growth in young patients, is effective in patients with osteoporosis, and gives a high rate of union


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 10 | Pages 1373 - 1377
1 Oct 2009
Spiegelberg BGI Sewell MD Aston WJS Blunn GW Pollock R Cannon SR Briggs TWR

This paper describes the preliminary results of a proximal tibial endoprosthesis which spares the knee joint and enables retention of the natural articulation by replacing part of the tibial metaphysis and diaphysis. In eight patients who had a primary malignant bone tumour of the proximal tibia, the distal stem, which had a hydroxyapatite-coated collar to improve fixation, was cemented into the medullary canal. The proximal end had hydroxyapatite-coated extracortical plates which were secured to the remaining proximal tibial metaphysis using cortical screws. The mean age of the patients at operation was 28.9 years (8 to 43) and the mean follow-up was for 35 months (4 to 48). The mean Musculoskeletal Tumour Society score was 79% (57% to 90%), the mean Oxford Knee score was 40 points of 48 (36 to 46) and the mean knee flexion was 112° (100° to 120°). In one patient, revision to a below-knee amputation through the prosthesis was required because of recurrence of the tumour. Another patient sustained a periprosthetic fracture which healed with a painful malunion. This was revised to a further endoprosthesis which replaced the knee. In the remaining six patients the prosthesis allowed preservation of the knee joint with good function and no early evidence of loosening. Further follow-up is required to assess the longevity of these prostheses


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 2 | Pages 213 - 218
1 Mar 1995
Maruyama M

A clay containing hydroxyapatite (HA) was developed for use as a filling material between an uncemented implant and bone. It consists of 55% HA granules greater than 0.1 mm in size with a homogeneous pore distribution and a porosity of 35% to 48% in a saline solution of sodium alginate (6%). Ti-6A1-4V alloy rods with smooth surfaces were implanted into the distal medullary canal of one osteotomised tibia of 32 Japanese white rabbits. Sixteen rods were inserted with HA clay and 16 without the clay to act as a control group. Six of each group were killed at one week and ten at 12 weeks postoperatively. The pull-out strength of the implants with HA clay was significantly greater at 12 weeks (p < 0.05), as was the percentage of the area of the new bone (p < 0.05). The study suggests that HA clay has an osteoconductive property, allowing adequate bone fixation across a gap at an early stage. The use of HA clay to enhance the early stability of uncemented components may help to improve the functional outcome of total joint arthroplasty


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 6 | Pages 994 - 998
1 Nov 1998
Kumta SM Leung PC Griffith JF Roebuck DJ Chow LTC Li CK

The aim of limb-salvage surgery in malignant bone tumours in children is to restore function and eradicate local disease with as little morbidity as possible. Allografts are associated with a high rate of complications, particularly malunion at the allograft-host junction. We describe a simple technique which enhances union of allograft to host bone taking advantage of the discrepancy in size between the adult allograft and the child’s bone. This involves lifting a flap of periosteum before resection from the host bone, which is then telescoped into the allograft medullary canal, which may require internal burring or splitting, for a distance of 1.5 to 2 cm and covering the bone junction with the periosteal flap. This is more stable than conventional end-to-end opposition. For each centimetre of telescoping the surface area available for bony union is increased more than three times. The periosteal flap also augments union. Additional surface fixation with a plate and screws is not necessary. We have used this technique in nine children, in eight of whom there was complete union at a mean of 16 weeks. Delayed union, associated with generalised limb osteoporosis, occurred in one. Early mobilisation, with weight-bearing by three weeks, was possible. There was only one fracture of the allograft


The Bone & Joint Journal
Vol. 106-B, Issue 6 | Pages 632 - 638
1 Jun 2024
Hart CM Kelley BV Mamouei Z Turkmani A Ralston M Arnold M Bernthal NM Sassoon AA

Aims

Delayed postoperative inoculation of orthopaedic implants with persistent wound drainage or bacterial seeding of a haematoma can result in periprosthetic joint infection (PJI). The aim of this in vivo study was to compare the efficacy of vancomycin powder with vancomycin-eluting calcium sulphate beads in preventing PJI due to delayed inoculation.

Methods

A mouse model of PJI of the knee was used. Mice were randomized into groups with intervention at the time of surgery (postoperative day (POD) 0): a sterile control (SC; n = 6); infected control (IC; n = 15); systemic vancomycin (SV; n = 9); vancomycin powder (VP; n = 21); and vancomycin bead (VB; n = 19) groups. Delayed inoculation was introduced during an arthrotomy on POD 7 with 1 × 105 colony-forming units (CFUs) of a bioluminescent strain of Staphylococcus aureus. The bacterial burden was monitored using bioluminescence in vivo. All mice were killed on POD 21. Implants and soft-tissue were harvested and sonicated for analysis of the CFUs.