Advertisement for orthosearch.org.uk
Results 1 - 20 of 754
Results per page:
The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1294 - 1302
1 Dec 2023
Knoll L Steppacher SD Furrer H Thurnheer-Zürcher MC Renz N

Aims. A higher failure rate has been reported in haematogenous periprosthetic joint infection (PJI) compared to non-haematogenous PJI. The reason for this difference is unknown. We investigated the outcome of haematogenous and non-haematogenous PJI to analyze the risk factors for failure in both groups of patients. Methods. Episodes of knee or hip PJI (defined by the European Bone and Joint Infection Society criteria) treated at our institution between January 2015 and October 2020 were included in a retrospective PJI cohort. Episodes with a follow-up of > one year were stratified by route of infection into haematogenous and non-haematogenous PJI. Probability of failure-free survival was estimated using the Kaplan-Meier method, and compared between groups using log-rank test. Univariate and multivariate analysis was applied to assess risk factors for failure. Results. A total of 305 PJI episodes (174 hips, 131 knees) were allocated to the haematogenous (n = 146) or the non-haematogenous group (n = 159). Among monomicrobial infections, Staphylococcus aureus was the dominant pathogen in haematogenous PJI (76/140, 54%) and coagulase-negative staphylococci in non-haematogenous PJI (57/133, 43%). In both groups, multi-stage exchange (n = 55 (38%) in haematogenous and n = 73 (46%) in non-haematogenous PJI) and prosthesis retention (n = 70 (48%) in haematogenous and n = 48 (30%) in non-haematogenous PJI) were the most common surgical strategies. Median duration of antimicrobial treatment was 13.5 weeks (range, 0.5 to 218 weeks) and similar in both groups. After six years of follow-up, the probability of failure-free survival was significantly lower in haematogenous compared to non-haematogenous PJI (55% vs 74%; p = 0.021). Infection-related mortality was significantly higher in haematogenous than non-haematogenous PJI (7% vs 0% episodes; p = 0.001). Pathogenesis of failure was similar in both groups. Retention of the prosthesis was the only independent risk factor for failure in multivariate analysis in both groups. Conclusion. Treatment failure was significantly higher in haematogenous compared to non-haematogenous PJI. Retention of the prosthesis was the only independent risk factor for failure in both groups. Cite this article: Bone Joint J 2023;105-B(12):1294–1302


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 8 | Pages 1011 - 1016
1 Aug 2011
Langton DJ Jameson SS Joyce TJ Gandhi JN Sidaginamale R Mereddy P Lord J Nargol AVF

There is widespread concern regarding the incidence of adverse soft-tissue reactions after metal-on-metal (MoM) hip replacement. Recent National Joint Registry data have shown clear differences in the rates of failure of different designs of hip resurfacing. Our aim was to update the failure rates related to metal debris for the Articular Surface Replacement (ASR). A total of 505 of these were implanted. Kaplan-Meier analysis showed a failure rate of 25% at six years for the ASR resurfacing and of 48.8% for the ASR total hip replacement (THR). Of 257 patients with a minimum follow-up of two years, 67 (26.1%) had a serum cobalt concentration which was greater than 7 μg/l. Co-ordinate measuring machine analysis of revised components showed that all patients suffering adverse tissue reactions in the resurfacing group had abnormal wear of the bearing surfaces. Six THR patients had relatively low rates of articular wear, but were found to have considerable damage at the trunion-taper interface. Our results suggest that wear at the modular junction is an important factor in the development of adverse tissue reactions after implantation of a large-diameter MoM THR


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 4 | Pages 504 - 509
1 May 2004
Lie SA Havelin LI Furnes ON Engesæter LB Vollset SE

We present the results for 4762 revision total hip arthroplasties with no previous infection in the hip, which were reported to the Norwegian Arthroplasty Register between 1987 and 2003. The ten-year failure rate for revised prostheses was 26% (95% CI 25 to 26). Cox regression analyses were undertaken separately for acetabular and femoral revision components. Cemented revision components without allograft was the reference category. For acetabular components, we found a significantly reduced risk of failure for uncemented revisions both with (relative risk (RR) = 0.66; 95% CI 0.43 to 0.99) and without (RR = 0.37; 95% CI 0.22 to 0.61) allograft. For femoral components, we found a significantly reduced risk of failure for uncemented revisions, both with (RR = 0.27; 95% CI 0.16 to 0.46) and without (RR = 0.22; 95% CI 0.11 to 0.46) unimpacted allograft. This reduced risk of failure also applied to cemented revision components with allograft (RR = 0.53; 95% CI 0.33 to 0.84) and with impaction bone grafting (RR = 0.34; 95% CI 0.19 to 0.62). Revision prostheses have generally inferior results when compared with primary prostheses. Recementation without allograft, and uncemented revision with bone impaction, were associated with worse results than the other revision techniques which we studied


The Bone & Joint Journal
Vol. 99-B, Issue 5 | Pages 653 - 659
1 May 2017
Akgün D Trampuz A Perka C Renz N

Aims

To investigate the outcomes of treatment of streptococcal periprosthetic joint infection (PJI) involving total knee and hip arthroplasties.

Patients and Methods

Streptococcal PJI episodes which occurred between January 2009 and December 2015 were identified from clinical databases. Presentation and clinical outcomes for 30 streptococcal PJIs in 30 patients (12 hip and 18 knee arthroplasties) following treatment were evaluated from the medical notes and at review. The Kaplan-Meier survival method was used to estimate the probability of infection-free survival. The influence of the biofilm active antibiotic rifampin was also assessed.


Bone & Joint Open
Vol. 5, Issue 7 | Pages 570 - 580
10 Jul 2024
Poursalehian M Ghaderpanah R Bagheri N Mortazavi SMJ

Aims. To systematically review the predominant complication rates and changes to patient-reported outcome measures (PROMs) following osteochondral allograft (OCA) transplantation for shoulder instability. Methods. This systematic review, following PRISMA guidelines and registered in PROSPERO, involved a comprehensive literature search using PubMed, Embase, Web of Science, and Scopus. Key search terms included “allograft”, “shoulder”, “humerus”, and “glenoid”. The review encompassed 37 studies with 456 patients, focusing on primary outcomes like failure rates and secondary outcomes such as PROMs and functional test results. Results. A meta-analysis of primary outcomes across 17 studies revealed a dislocation rate of 5.1% and an increase in reoperation rates from 9.3% to 13.7% post-publication bias adjustment. There was also a noted rise in conversion to total shoulder arthroplasty and incidence of osteoarthritis/osteonecrosis over longer follow-up periods. Patient-reported outcomes and functional tests generally showed improvement, albeit with notable variability across studies. A concerning observation was the consistent presence of allograft resorption, with rates ranging from 33% to 80%. Comparative studies highlighted similar efficacy between distal tibial allografts and Latarjet procedures in most respects, with some differences in specific tests. Conclusion. OCA transplantation presents a promising treatment option for shoulder instability, effectively addressing both glenoid and humeral head defects with favourable patient-reported outcomes. These findings advocate for the inclusion of OCA transplantation in treatment protocols for shoulder instability, while also emphasizing the need for further high-quality, long-term research to better understand the procedure’s efficacy profile. Cite this article: Bone Jt Open 2024;5(7):570–580


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 5 | Pages 608 - 615
1 May 2011
Bolland BJRF Culliford DJ Langton DJ Millington JPS Arden NK Latham JM

This study reports the mid-term results of a large-bearing hybrid metal-on-metal total hip replacement in 199 hips (185 patients) with a mean follow-up of 62 months (32 to 83). Two patients died of unrelated causes and 13 were lost to follow-up. In all, 17 hips (8.5%) have undergone revision, and a further 14 are awaiting surgery. All revisions were symptomatic. Of the revision cases, 14 hips showed evidence of adverse reactions to metal debris. The patients revised or awaiting revision had significantly higher whole blood cobalt ion levels (p = 0.001), but no significant difference in acetabular component size or position compared with the unrevised patients. Wear analysis (n = 5) showed increased wear at the trunnion-head interface, normal levels of wear at the articulating surfaces and evidence of corrosion on the surface of the stem. The cumulative survival rate, with revision for any reason, was 92.4% (95% confidence interval 87.4 to 95.4) at five years. Including those awaiting surgery, the revision rate would be 15.1% with a cumulative survival at five years of 89.6% (95% confidence interval 83.9 to 93.4). This hybrid metal-on-metal total hip replacement series has shown an unacceptably high rate of failure, with evidence of high wear at the trunnion-head interface and passive corrosion of the stem surface. This raises concerns about the use of large heads on conventional 12/14 tapers


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 2 | Pages 243 - 246
1 Mar 1992
Nafei A Nielsen S Kristensen O Hvid I

We report the results of 75 consecutive primary press-fit Kinemax arthroplasties with an average follow-up of 14 months (three to 28). We reviewed 26 cemented and 49 non-cemented tibial components implanted into 72 patients (30 men and 42 women, median age 70 years). At the latest follow-up the overall evaluation (Hospital for Special Surgery knee rating scale) for cemented cases was excellent in 54%, good in 42% and poor in 4%. No cemented prosthesis loosened. Of the non-cemented cases 55% were excellent, 23% good, and 2% fair. Ten tibial implants (20%) loosened and required revision. Residual pain marred the result in 24% of the non-cemented prostheses and in 4% of the cemented group. We do not recommend the press-fit, smooth-surfaced Kinemax prosthesis for non-cemented use.


The Bone & Joint Journal
Vol. 98-B, Issue 4 | Pages 512 - 518
1 Apr 2016
Spencer HT Hsu L Sodl J Arianjam A Yian EH

Aims

To compare radiographic failure and re-operation rates of anatomical coracoclavicular (CC) ligament reconstructional techniques with non-anatomical techniques after chronic high grade acromioclavicular (AC) joint injuries.

Patients and Methods

We reviewed chronic AC joint reconstructions within a region-wide healthcare system to identify surgical technique, complications, radiographic failure and re-operations. Procedures fell into four categories: (1) modified Weaver-Dunn, (2) allograft fixed through coracoid and clavicular tunnels, (3) allograft loop coracoclavicular fixation, and (4) combined allograft loop and synthetic cortical button fixation. Among 167 patients (mean age 38.1 years, (standard deviation (sd) 14.7) treated at least a four week interval after injury, 154 had post-operative radiographs available for analysis.


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 151 - 157
1 Feb 2024
Dreyer L Bader C Flörkemeier T Wagner M

Aims. The risk of mechanical failure of modular revision hip stems is frequently mentioned in the literature, but little is currently known about the actual clinical failure rates of this type of prosthesis. The current retrospective long-term analysis examines the distal and modular failure patterns of the Prevision hip stem from 18 years of clinical use. A design improvement of the modular taper was introduced in 2008, and the data could also be used to compare the original and the current design of the modular connection. Methods. We performed an analysis of the Prevision modular hip stem using the manufacturer’s vigilance database and investigated different mechanical failure patterns of the hip stem from January 2004 to December 2022. Results. Two mechanical failure patterns were identified: fractures in the area of the distal fluted profile (distal stem fracture) and failure of the modular taper (modular fracture). A failure rate of 0.07% was observed for distal stem fracture, and modular fracture rates of 1.74% for the original and 0.013% for the current taper design. Conclusion. A low risk of mechanical failure for both fracture types was observed compared to other known complications in revision hip arthroplasty. In addition, the data show that a design change did significantly reduce the risk of a modular fracture. Cite this article: Bone Joint J 2024;106-B(2):151–157


Bone & Joint Open
Vol. 4, Issue 5 | Pages 329 - 337
8 May 2023
Khan AQ Chowdhry M Sherwani MKA McPherson EJ

Aims. Total hip arthroplasty (THA) is considered the preferred treatment for displaced proximal femoral neck fractures. However, in many countries this option is economically unviable. To improve outcomes in financially disadvantaged populations, we studied the technique of concomitant valgus hip osteotomy and operative fixation (VOOF). This prospective serial study compares two treatment groups: VOOF versus operative fixation alone with cannulated compression screws (CCSs). Methods. In the first series, 98 hip fixation procedures were performed using CCS. After fluoroscopic reduction of the fracture, three CCSs were placed. In the second series, 105 VOOF procedures were performed using a closing wedge intertrochanteric osteotomy with a compression lag screw and lateral femoral plate. The alignment goal was to create a modified Pauwel’s fracture angle of 30°. After fluoroscopic reduction of fracture, lag screw was placed to achieve the calculated correction angle, followed by inter-trochanteric osteotomy and placement of barrel plate. Patients were followed for a minimum of two years. Results. Mean follow-up was 4.6 years (4.1 to 5.0) in the CCS group and 5.5 years (5.25 to 5.75) in the VOOF group. The mean Harris Hip Score at two-year follow-up was 83.85 in the CCS group versus 88.00 in the VOOF group (p < 0.001). At the latest follow-up, all-cause failure rate was 29.1% in the CCS group and 11.7% in the VOOF group (p = 0.003). The total cost of the VOOF technique was 7.2% of a THA, and total cost of the CCS technique was 6.3% of a THA. Conclusion. The VOOF technique decreased all-cause failure rate compared to CCS. The total cost of VOOF was 13.5% greater than CCS, but 92.8% less than a THA. Increased cost of VOOF was considered acceptable to all patients in this series. VOOF technique provides a reasonable alternative to THA in patients who cannot afford a THA procedure. Cite this article: Bone Jt Open 2023;4(5):329–337


The Bone & Joint Journal
Vol. 105-B, Issue 3 | Pages 301 - 306
1 Mar 2023
Jennison T Ukoumunne O Lamb S Sharpe I Goldberg AJ

Aims. Despite the increasing numbers of ankle arthroplasties, there are limited studies on their survival and comparisons between different implants. The primary aim of this study was to determine the failure rates of primary ankle arthroplasties commonly used in the UK. Methods. A data linkage study combined National Joint Registry (NJR) data and NHS Digital data. The primary outcome of failure was defined as the removal or exchange of any components of the implanted device. Life tables and Kaplan-Meier survival charts were used to illustrate survivorship. Cox proportional hazards regression models were fitted to compare failure rates between 1 April 2010 and 31 December 2018. Results. Overall, 5,562 primary ankle arthroplasties were recorded in the NJR. Linked data show a one-year survivorship of 98.8% (95% confidence interval (CI) 98.4% to 99.0%), five-year survival in 2,725 patients of 90.2% (95% CI 89.2% to 91.1%), and ten-year survival in 199 patients of 86.2% (95% CI 84.6% to 87.6%). The five-year survival for fixed-bearing implants was 94.3% (95% CI 91.3% to 96.3%) compared to 89.4% (95% CI 88.3% to 90.4%) for mobile-bearing implants. A Cox regression model for all implants with over 100 implantations using the implant with the best survivorship (Infinity) as the reference, only the STAR (hazard ratio (HR) 1.60 (95% CI 0.87 to 2.96)) and INBONE (HR 0.38 (95% CI 0.05 to 2.84)) did not demonstrate worse survival at three and five years. Conclusion. Ankle arthroplasties in the UK have a five-year survival rate of 90.2%, which is lower than recorded on the NJR, because we have shown that approximately one-third of ankle arthroplasty failures are not reported to the NJR. There are statistically significant differences in survival between different implants. Fixed-bearing implants appear to demonstrate higher survivorship than mobile-bearing implants. Cite this article: Bone Joint J 2023;105-B(3):301–306


The Bone & Joint Journal
Vol. 105-B, Issue 11 | Pages 1184 - 1188
1 Nov 2023
Jennison T Ukoumunne OC Lamb S Goldberg AJ Sharpe I

Aims. The number of revision total ankle arthroplasties (TAAs) which are undertaken is increasing. Few studies have reported the survival after this procedure. The primary aim of this study was to analyze the survival of revision ankle arthroplasties using large datasets. Secondary aims were to summarize the demographics of the patients, the indications for revision TAA, further operations, and predictors of survival. Methods. The study combined data from the National Joint Registry and NHS Digital to report the survival of revision TAA. We have previously reported the failure rates and risk factors for failure after TAA, and the outcome of fusion after a failed TAA, using the same methodology. Survival was assessed using life tables and Kaplan Meier graphs. Cox proportional hazards regression models were fitted to compare failure rates. Results. A total of 228 patients underwent revision TAA. The mean follow-up was 2.6 years (SD 2.0). The mean time between the initial procedure and revision was 2.3 years (SD 1.8). The most commonly used implant was the Inbone which was used in 81 patients. A total of 29 (12.7%) failed; nine (3.9%) patients underwent a further revision, 19 (8.3%) underwent a fusion, and one (0.4%) had an amputation. The rate of survival was 95.4% (95% confidence interval (CI) 91.6 to 97.5) at one year, 87.7% (95% CI 81.9 to 91.7; n = 124) at three years and 77.5% (95% CI 66.9 to 85.0; n = 57) at five years. Revision-specific implants had a better survival than when primary implants were used at revision. A total of 50 patients (21.9%) had further surgery; 19 (8.3%) underwent reoperation in the first 12 months. Cox regression models were prepared. In crude analysis the only significant risk factors for failure were the use of cement (hazard ratio (HR) 3.02 (95% CI 1.13 to 8.09)) and the time since the primary procedure (HR 0.67 (95% CI 0.47 to 0.97)). No risk factors for failure were identified in multivariable Cox regression modelling. Conclusion. Revision TAAs have good medium term survival and low rates of further surgery. New modular revision implants appear to have improved the survival compared with the use of traditional primary implants at revision. Cite this article: Bone Joint J 2023;105-B(11):1184–1188


The Bone & Joint Journal
Vol. 104-B, Issue 6 | Pages 657 - 662
1 Jun 2022
Barlow T Coco V Shivji F Grassi A Asplin L Thompson P Metcalfe A Zaffagnini S Spalding T

Aims. Meniscal allograft transplantation (MAT) for patients with symptomatic meniscal loss has demonstrated good clinical results and survivorship. Factors that affect both functional outcome and survivorship have been reported in the literature. These are typically single-centre case series with relatively small numbers and conflicting results. Our aim was to describe an international, two-centre case series, and identify factors that affect both functional outcome and survival. Methods. We report factors that affect outcome on 526 patients undergoing MAT across two sites (one in the UK and one in Italy). Outcomes of interest were the Knee injury and Osteoarthritis Outcome Score four (KOOS4) at two years and failure rates. We performed multiple regression analysis to examine for factors affecting KOOS, and Cox proportional hazards models for survivorship. Results. Our results indicate that baseline KOOS4 score affects functional outcome at two years, but no other included factors were significantly related to functional outcome. The only factor that affected failure rate was the presence of cartilage lesions down to bone on both the femur and tibia, decreasing the five-year survivorship from 95% (95% confidence interval (CI) 91 to 99) to 84% (95% CI 74 to 94). Conclusion. To our knowledge, this is the largest international cohort reporting on MAT. Our results indicate that factors such as age, BMI, and cartilage lesions down to bone on both the femur and tibia of the affected compartment should not present barriers to offering MAT. Baseline KOOS4 score and the presence of bone-on-bone arthritis can be used to help counsel patients regarding the expected risks and rewards of surgery. Cite this article: Bone Joint J 2022;104-B(6):657–662


Bone & Joint 360
Vol. 13, Issue 5 | Pages 24 - 26
1 Oct 2024

The October 2024 Knee Roundup. 360. looks at: Managing the unexpected: treatment of intraoperative medial collateral ligament injuries; Identifying subgroups of patients that may benefit from robotic arm-assisted total knee arthroplasty: secondary analysis of data from a randomized controlled trial; Cost-effectiveness of enoxaparin versus aspirin in the prevention of venous thromboembolism after total hip or knee arthroplasty: an analysis from the CRISTAL cluster-randomized trial; Cartilage regeneration and long-term survival in medial knee osteoarthritis patients treated with high tibial osteotomy and osteochondral autologous transfer system; Treatment of chronic and complex meniscal tears with arthroscopic meniscus repair augmented with collagen matrix wrapping: failure rate and functional outcomes; Long-term outcomes of multiligament knee injuries in American football players


Bone & Joint Open
Vol. 3, Issue 6 | Pages 485 - 494
13 Jun 2022
Jaubert M Le Baron M Jacquet C Couvreur A Fabre-Aubrespy M Flecher X Ollivier M Argenson J

Aims. Two-stage exchange revision total hip arthroplasty (THA) performed in case of periprosthetic joint infection (PJI) has been considered for many years as being the gold standard for the treatment of chronic infection. However, over the past decade, there have been concerns about its safety and its effectiveness. The purposes of our study were to investigate our practice, collecting the overall spacer complications, and then to analyze their risk factors. Methods. We retrospectively included 125 patients with chronic hip PJI who underwent a staged THA revision performed between January 2013 and December 2019. All spacer complications were systematically collected, and risk factors were analyzed. Statistical evaluations were performed using the Student's t-test, Mann-Whitney U test, and Fisher's exact test. Results. Our staged exchange practice shows poor results, which means a 42% mechanical spacer failure rate, and a 20% recurrent infection rate over the two years average follow-up period. Moreover, we found a high rate of spacer dislocation (23%) and a low rate of spacer fracture (8%) compared to the previous literature. Our findings stress that the majority of spacer complications and failures is reflecting a population with high comorbid burden, highlighted by the American Society of Anesthesiology grade, Charlson Comorbidity Index, and Lee score associations, as well as the cardiac, pulmonary, kidney, or hepatic chronic conditions. Conclusion. Our experience of a two-stage hip exchange revision noted important complication rates associated with high failure rates of polymethylmethacrylate spacers. These findings must be interpreted in the light of the patient’s comorbidity profiles, as the elective population for staged exchange has an increasing comorbid burden leading to poor results. In order to provide better results for this specific population, our conclusion suggests that comparative strategy studies are required to improve our therapeutic indication. Cite this article: Bone Jt Open 2022;3(6):485–494


Bone & Joint Open
Vol. 2, Issue 7 | Pages 509 - 514
12 Jul 2021
Biddle M Kennedy IW Wright PM Ritchie ND Meek RMD Rooney BP

Aims. Periprosthetic hip and knee infection remains one of the most severe complications following arthroplasty, with an incidence between 0.5% to 1%. This study compares the outcomes of revision surgery for periprosthetic joint infection (PJI) following hip and knee arthroplasty prior to and after implementation of a specialist PJI multidisciplinary team (MDT). Methods. Data was retrospectively analyzed from a single centre. In all, 29 consecutive joints prior to the implementation of an infection MDT in November 2016 were compared with 29 consecutive joints subsequent to the MDT conception. All individuals who underwent a debridement antibiotics and implant retention (DAIR) procedure, a one-stage revision, or a two-stage revision for an acute or chronic PJI in this time period were included. The definition of successfully treated PJI was based on the Delphi international multidisciplinary consensus. Results. There were no statistically significant differences in patient demographics or comorbidities between the groups. There was also no significant difference in length of overall hospital stay (p = 0.530). The time taken for formal microbiology advice was significantly shorter in the post MDT group (p = 0.0001). There was a significant difference in failure rates between the two groups (p = 0.001), with 12 individuals (41.38%) pre-MDT requiring further revision surgery compared with one individual (6.67%) post-MDT inception. Conclusion. Our standardized multidisciplinary approach for periprosthetic knee and hip joint infection shows a significant reduction in failure rates following revision surgery. Following implementation of our MDT, our success rate in treating PJI is 96.55%, higher than what current literature suggests. We advocate the role of a specialist infection MDT in the management of patients with a PJI to allow an individualized patient-centred approach and care plan, thereby reducing postoperative complications and failure rates. Cite this article: Bone Jt Open 2021;2(7):509–514


The Bone & Joint Journal
Vol. 105-B, Issue 10 | Pages 1094 - 1098
1 Oct 2023
Jennison T Ukoumunne OC Lamb S Sharpe I Goldberg AJ

Aims. When a total ankle arthroplasty (TAA) fails, it can be converted to a fusion or a revision arthroplasty. Despite the increasing numbers of TAAs being undertaken, there is little information in the literature about the management of patients undergoing fusion following a failed TAA. The primary aim of this study was to analyze the survival of fusions following a failed TAA using a large dataset from the National Joint Registry (NJR). Methods. A data linkage study combined NJR and NHS Digital data. Failure of a TAA was defined as a fusion, revision to a further TAA, or amputation. Life tables and Kaplan-Meier graphs were used to record survival. Cox proportional hazards regression models were fitted to compare the rates of failure. Results. A total of 131 patients underwent fusion as a salvage procedure following TAA. Their mean age was 65.7 years (SD 10.6) and 73 (55.7%) were male. The mean follow-up was 47.5 months (SD 27.2). The mean time between TAA and fusion was 5.3 years (SD 2.7). Overall, 32 (24.4%) underwent reoperations other than revision and 29 (22.1%) failed. Of these 24 (18.3%) underwent revision of the fusion and five (3.8%) had a below-knee amputation. No patients underwent conversion to a further TAA. Failure usually occurred in the first three postoperative years with one-year survival of fusion being 96.0% (95% confidence interval (CI) 90.7 to 98.3) and three-year survival in 69 patients being 77.5% (95% CI 68.3 to 84.4). Conclusion. Salvage fusion after a failed TAA shows moderate rates of failure and reoperations. Nearly 25% of patients required revision within three years. This study is an extension of studies using the same methodology reporting the failure rates and risk factors for failure, which have recently been published, and also one reporting the outcome of revision TAA for a failed primary TAA, using the same methodology, which will shortly be published. Cite this article: Bone Joint J 2023;105-B(10):1094–1098


Bone & Joint Open
Vol. 4, Issue 10 | Pages 776 - 781
16 Oct 2023
Matar HE Bloch BV James PJ

Aims. The aim of this study was to evaluate medium- to long-term outcomes and complications of the Stanmore Modular Individualised Lower Extremity System (SMILES) rotating hinge implant in revision total knee arthroplasty (rTKA) at a tertiary unit. It is hypothesized that this fully cemented construct leads to satisfactory clinical outcomes. Methods. A retrospective consecutive study of all patients who underwent a rTKA using the fully cemented SMILES rotating hinge prosthesis between 2005 to 2018. Outcome measures included aseptic loosening, reoperations, revision for any cause, complications, and survivorship. Patients and implant survivorship data were identified through both prospectively collected local hospital electronic databases and linked data from the National Joint Registry/NHS Personal Demographic Service. Kaplan-Meier survival analysis was used at ten years. Results. Overall, 69 consecutive patients (69 knees) were included with a median age of 78 years (interquartile range 69 to 84), and there were 46 females (66.7%). Indications were septic revisions in 26 (37.7%), and aseptic aetiology in the remining 43 (62.3%). The mean follow-up was 9.7 years (4 to 18), and the overall complication was rate was 7.24%, all with patellofemoral complications. Failure rate with ‘any cause revision’ was 5.8%. There was one case of aseptic loosening of the femoral component. At ten years, 17/69 patients (24.63%) had died, and implant survivorship was 92.2%. Conclusion. In our experience, the SMILES rotating hinge prosthesis achieves satisfactory long-term outcomes with ten-year implant survivorship of 92.2% and a patellofemoral complication rate of 7.24%. Cite this article: Bone Jt Open 2023;4(10):776–781


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1067 - 1073
1 Oct 2024
Lodge CJ Adlan A Nandra RS Kaur J Jeys L Stevenson JD

Aims. Periprosthetic joint infection (PJI) is a challenging complication of any arthroplasty procedure. We reviewed our use of static antibiotic-loaded cement spacers (ABLCSs) for staged management of PJI where segmental bone loss, ligamentous instability, or soft-tissue defects necessitate a static construct. We reviewed factors contributing to their failure and techniques to avoid these complications when using ABLCSs in this context. Methods. A retrospective analysis was conducted of 94 patients undergoing first-stage revision of an infected knee prosthesis between September 2007 and January 2020 at a single institution. Radiographs and clinical records were used to assess and classify the incidence and causes of static spacer failure. Of the 94 cases, there were 19 primary total knee arthroplasties (TKAs), ten revision TKAs (varus-valgus constraint), 20 hinged TKAs, one arthrodesis (nail), one failed spacer (performed elsewhere), 21 distal femoral endoprosthetic arthroplasties, and 22 proximal tibial arthroplasties. Results. A total of 35/94 patients (37.2%) had spacer-related complications, of which 26/35 complications (74.3%) were because of mechanical failure of the spacer construct, while 9/35 (25.7%) were due to recurrence of infection. Risk factors for internal failure were a construct where the total intramedullary spacer length was less than twice the length of the central osseous defect (p = 0.009), where proximal or distal intraosseous spacer contact was < 10%, and after tibial tubercle osteotomy (p = 0.005). The incidence of spacer complications significantly increased the time to second stage: mean 157 days (42 to 458) in those without complications versus 227 days (11 to 528) with complications (p = 0.014). Conclusion. The failure rate of static antibiotic-loaded cement spacers is much higher than anticipated. Complications of the spacer significantly increased the time to second-stage revision. The risk of mechanical failure is significantly increased if the spacer is less than double the size of the segmental defect, or if inadequate reinforcement is inserted into the residual bone. These findings serve as a guide for surgeons to avoid mechanical complications with static spacers. Cite this article: Bone Joint J 2024;106-B(10):1067–1073


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1279 - 1285
1 Dec 2023
Baker JF Nadar AC Jouflas AC Smith LS Sachdeva S Yakkanti MR Malkani AL

Aims. The use of cementless total knee arthroplasty (TKA) components has increased during the past decade. The initial design of cementless metal-backed patellar components had shown high failure rates due to many factors. The aim of this study was to evaluate the clinical results of a second-generation cementless, metal-backed patellar component of a modern design. Methods. This was a retrospective review of 707 primary TKAs in 590 patients from a single institution, using a cementless, metal-backed patellar component with a mean follow-up of 6.9 years (2 to 12). A total of 409 TKAs were performed in 338 females and 298 TKAs in 252 males. The mean age of the patients was 63 years (34 to 87) and their mean BMI was 34.3 kg/m. 2. (18.8 to 64.5). The patients were chosen to undergo a cementless procedure based on age and preoperative radiological and intraoperative bone quality. Outcome was assessed using the Knee Society knee and function scores and range of motion (ROM), complications, and revisions. Results. A total of 24 TKAs (3.4%) in 24 patients failed and required revision surgery, of which five were due to patellar complications (0.71%): one for aseptic patellar loosening (0.14%) and four for polyethylene dissociation (0.57%). A total of 19 revisions (2.7%) were undertaken in 19 patients for indications which did not relate to the patella: four for aseptic tibial loosening (0.57%), one for aseptic femoral loosening (0.14%), nine for periprosthetic infection (1.3%), one for popliteus impingement (0.14%), and four for instability (0.57%). Knee Society knee and function scores, and ROM, improved significantly when comparing pre- and postoperative values. Survival of the metal-backed patellar component for all-cause failure was 97.5% (95% confidence interval 94.9% to 100%) at 12 years. Conclusion. The second-generation cementless TKA design of metal-backed patellar components showed a 97.5% survival at 12 years, with polyethylene dissociation from the metal-backing being the most common cause of patellar failure. In view of the increased use of TKA, especially in younger, more active, or obese patients, these findings are encouraging at mean follow-up of seven years. Cite this article: Bone Joint J 2023;105-B(12):1279–1285