Advertisement for orthosearch.org.uk
Results 1 - 14 of 14
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 4 | Pages 663 - 664
1 Jul 1995
Howard C Einhorn M Dagan R Nyska M


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 3 | Pages 463 - 467
1 May 1994
Porat S Robin G Howard C

Fifteen patients who limped and had early fatigue on walking caused by ischaemic necrosis after treatment for congenital dislocation of the hip had distal and lateral transfer of the greater trochanter. Nine of them in whom the predicted leg-length discrepancy was more than 3 cm also had epiphysiodesis of the contralateral leg. At skeletal maturity the limp was eliminated and walking distance was significantly improved in them all. In those who had epiphysiodesis the average leg-length discrepancy was 0.7 cm at maturity. Two of those not treated by epiphysiodesis used a heel raise of 1.5 cm. In seven cases the two operations were performed simultaneously without serious complications. This procedure is recommended at about the age of 12 years.


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 2 | Pages 311 - 314
1 Mar 1994
Howard C Einhorn M Dagan R Yagupski P Porat S

In 30 patients in whom osteomyelitis was suspected fine-needle bone biopsies (FNBB) were taken at the same time as bone was aspirated for bacteriological examination. The diagnosis of osteomyelitis was eventually confirmed in 15 patients; the other 15 had myositis (3), arthritis (3), trauma (2), microgeodic phalangeal syndrome (2), haematoma in a non-ossifying fibroma (1), and Ewing's sarcoma (1). In three patients no pathology was found. The temperature, WBC and ESR at presentation did not help to distinguish osteomyelitis from other conditions. FNBB, however, proved to be a useful additional investigation with a sensitivity for osteomyelitis of 87% and a specificity of 93%.


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 1 | Pages 79 - 82
1 Jan 1993
Howard C Einhorn M Dagan R Nyska M

We reviewed the ultrasound findings in 59 children suspected of having bone infection. Twenty-nine were eventually proved to have acute haematogenous osteomyelitis and 26 of these showed characteristic ultrasound findings. Such changes were rare in 30 patients with other clinically similar conditions. Ultrasound examination was also able to detect the presence of subperiosteal pus and thus indicate the need for surgical treatment.


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 4 | Pages 620 - 623
1 Jul 1992
Howard C Benson M

We studied the ossific nuclei on radiographs of the feet of three stillborn infants, two with club feet, relating the size, position and alignment of each nucleus to the cartilaginous talus or calcaneum in which it lay. Anteroposterior projections of the nucleus of the talus show deformity of that bone as well as subtalar malalignment. Lateral projections of the calcaneal nucleus may underestimate the degree of hindfoot equinus.


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 4 | Pages 528 - 533
1 Jul 1992
Tibrewal S Benson M Howard C Fuller D

We treated 63 club feet in 44 patients by a defined programme of strapping from birth followed by one of two operations performed at six weeks, either a simple calcaneal tendon lengthening or a subtalar realignment, and reviewed them prospectively. The decision as to which operation to perform was taken at four weeks after radiographic measurement of the talocalcaneal angle. All but eight patients (ten feet) were followed for a mean of 8.7 years. The overall results after calcaneal tendon lengthening were satisfactory. The re-operation rate after subtalar realignment was high (39%) due to over or undercorrection of the deformity.


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 3 | Pages 471 - 472
1 May 1992
Howard C Shinwell E Nyska M Meller I


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 1 | Pages 175 - 176
1 Jan 1991
Howard C Einhorun M


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 3 | Pages 423 - 427
1 May 1988
McKibbin B Freedman L Howard C Williams L

We describe the results of a policy of highly selective splintage for CDH, using knee plasters. No child suffered because splintage was withheld. In those who were treated the results were satisfactory and the proportion who required a subsequent operation was extremely low. Avascular necrosis was not a significant problem. The method, although a little more time consuming, appears to offer significant advantages over current alternatives.


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 4 | Pages 656 - 658
1 Aug 1985
Howard C Tayton K Gibbs A

The tissue surrounding carbon fibre reinforced epoxy resin plates applied to forearm and tibial fractures was biopsied in 32 patients at the time the plates were removed. The reaction was minimal and was compared with that in a control group of 16 similar patients in whom stainless steel plates were used. No significant histological differences were found. A series of experiments on rats, in which the histology was studied from 2 to 78 weeks, also showed that there was very little reaction to carbon fibre reinforced plastic.


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 4 | Pages 530 - 532
1 Aug 1985
Howard C McKibbin B Williams L Mackie I

We have studied the natural history of spontaneous dislocation of the hip in cerebral palsy, with particular reference to the pattern of neurological involvement. In patients with bilateral hemiplegia and severe involvement of the upper limbs the incidence of dislocation was very high (59%), while in those with diplegia and little involvement of the upper limbs, only 6.5% were affected. There was no evidence of dysplasia or instability of the hip in any of the patients with unilateral hemiplegia. A strong correlation was found between the stability of the hip and the patients' ability to walk. These findings have a bearing on clinical surveillance and also on the indications for prophylactic surgery.


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 2 | Pages 313 - 316
1 Mar 1985
Howard C McKibbin B Ralis Z

We have studied the use of filamentous polyglycolic acid (Dexon) for the induction of neotendon in the calcaneal tendon of sheep. Uniformly good results were obtained, with the formation of a thick neotendon. However, in a control group the power of spontaneous regeneration of the tendon was studied; it was found that, provided overlengthening of the gap was prevented, an equally good tendon resulted. It is concluded that this particular model is not an appropriate one for testing neotendon induction, despite its use for this purpose in the past. The favourable results of using filamentous polyglycolic acid as a tendon replacement suggest that it should be further investigated (in a more suitable model) since it may well have useful clinical applications.


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 2 | Pages 206 - 208
1 Mar 1984
Howard C Winston I Bell W Mackie I Jenkins D

Ruptures of the calcaneal tendon which present late may be repaired using carbon fibre to induce a neotendon. The operative technique is described and the results of five cases reviewed. The average muscle power obtained was 88% of normal, and the thickness of the neotendon was 148% of that of the normal side. It would appear that this tendon formation in man is comparable to that previously described in sheep.


The Journal of Bone & Joint Surgery British Volume
Vol. 64-B, Issue 5 | Pages 565 - 567
1 Dec 1982
Howard C Davies R

Ten cases of a complication of Garden screw fixation of subcapital fracture, namely subtrochanteric fracture through the lower screw hole, are presented. Their possible aetiology, prevention and difficulties in management are discussed. It is recommended that, during the insertion of Garden screws, care should be taken to avoid multiple attempts at passing the guide wire. If subtrochanteric fracture occurs internal fixation with a nail plate or screw plate is advised. Ideally the nail or screw should be inserted along the track of one of the existing screws.