Aims. Total hip arthroplasties (THAs) are performed by surgeons at various stages in training with varying levels of supervision, but we do not know if this is safe practice with comparable outcomes to consultant-performed THA. Our aim was to examine the association between surgeon grade, the senior supervision of trainees, and the risk of revision following THA. Methods. We performed an observational study using National Joint Registry (NJR) data. We included adult patients who underwent primary THA for osteoarthritis, recorded in the NJR between 2003 and 2016. Exposures were
Aims. To determine if primary cemented acetabular component geometry (long posterior wall (LPW), hooded, or offset reorientating) influences the risk of revision total hip arthroplasty (THA) for instability or loosening. Methods. The National Joint Registry (NJR) dataset was analyzed for primary THAs performed between 2003 and 2017. A cohort of 224,874 cemented acetabular components were included. The effect of acetabular component geometry on the risk of revision for instability or for loosening was investigated using log-binomial regression adjusting for age, sex, American Society of Anesthesiologists grade, indication, side, institution type,
In the UK, the agricultural, military, and construction sectors have stringent rules about the use of hearing protection due to the risk of noise-induced hearing loss. Orthopaedic staff may also be at risk due to the use of power tools. The UK Health and Safety Executive (HSE) have clear standards as to what are deemed acceptable occupational levels of noise on A-weighted and C-weighted scales. The aims of this review were to assess the current evidence on the testing of exposure to noise in orthopaedic operating theatres to see if it exceeds these regulations. A search of PubMed and EMBASE databases was conducted using PRISMA guidelines. The review was registered prospectively in PROSPERO. Studies which assessed the exposure to noise for orthopaedic staff in operating theatres were included. Data about the exposure to noise were extracted from these studies and compared with the A-weighted and C-weighted acceptable levels described in the HSE regulations.Aims
Methods
During the COVID-19 pandemic, drilling has been classified as an aerosol-generating procedure. However, there is limited evidence on the effects of bone drilling on splatter generation. Our aim was to quantify the effect of drilling on splatter generation within the orthopaedic operative setting. This study was performed using a Stryker System 7 dual rotating drill at full speed. Two fluid mediums (Videne (Solution 1) and Fluorescein (Solution 2)) were used to simulate drill splatter conditions. Drilling occurred at saw bone level (0 cm) and at different heights (20 cm, 50 cm, and 100 cm) above the target to simulate the surgeon ‘working arm length’, with and without using a drill guide. The furthest droplets were marked and the droplet displacement was measured in cm. A surgical microscope was used to detect microscopic droplets.Aims
Methods
Aims. Large bone defects resulting from osteolysis, fractures, osteomyelitis, or metastases pose significant challenges in acetabular reconstruction for total hip arthroplasty. This study aimed to evaluate the survival and radiological outcomes of an acetabular reconstruction technique in patients at high risk of reconstruction failure (i.e. periprosthetic joint infection (PJI), poor bone stock, immunosuppressed patients), referred to as Hip Reconstruction In Situ with Screws and Cement (HiRISC). This involves a polyethylene liner embedded in cement-filled bone defects reinforced with screws and/or plates for enhanced fixation. Methods. A retrospective chart review of 59 consecutive acetabular reconstructions was performed by four surgeons in a single institution from 18 October 2018 to 5 January 2023. Cases were classified based on the Paprosky classification, excluding type 1 cases (n = 26) and including types 2 or 3 for analysis (n = 33). Radiological loosening was evaluated by an orthopaedic surgeon who was not the
Objectives. The PROximal Fracture of the Humerus: Evaluation by Randomisation (PROFHER) trial has recently demonstrated that surgery is non-superior to non-operative treatment in the management of displaced proximal humeral fractures. The objective of this study was to assess current surgical practice in the context of the PROFHER trial in terms of patient demographics, injury characteristics and the nature of the surgical treatment. Methods. A total of ten consecutive patients undergoing surgery for the treatment of a proximal humeral fracture from each of 11 United Kingdom hospitals were retrospectively identified over a 15 month period between January 2014 and March 2015. Data gathered for the 110 patients included patient demographics, injury characteristics, mode of surgical fixation, the grade of
Aims. This study reports on the medium- to long-term implant survivorship
and patient-reported outcomes for the Avon patellofemoral joint
(PFJ) arthroplasty. Patients and Methods. A total of 558 Avon PFJ arthroplasties in 431 patients, with
minimum two-year follow-up, were identified from a prospective database.
Patient-reported outcomes and implant survivorship were analyzed,
with follow-up of up to 18 years. Results. Outcomes were recorded for 483 implants (368 patients), representing
an 86% follow-up rate. The median postoperative Oxford Knee Score
(0 to 48 scale) was 35 (interquartile range (IQR) 25.5 to 43) and
the median Western Ontario and McMaster Universities Osteoarthritis
Index (WOMAC, 0 to 100 scale) was 35 (IQR 25 to 53) at two years.
There were 105 revisions, 61 (58%) for progression of osteoarthritis.
All documented revisions were to primary knee systems without augmentation.
The implant survival rate was 77.3% (95% confidence interval (CI)
72.4 to 81.7, number at risk 204) at ten years and 67.4% (95% CI
72.4 to 81.7 number at risk 45) at 15 years. Regression analysis
of explanatory data variable showed that cases performed in the
last nine years had improved survival compared with the first nine
years of the cohort, but the individual
To investigate if preoperative CT improves detection of unstable trochanteric hip fractures. A single-centre prospective study was conducted. Patients aged 65 years or older with trochanteric hip fractures admitted to Stavanger University Hospital (Stavanger, Norway) were consecutively included from September 2020 to January 2022. Radiographs and CT images of the fractures were obtained, and surgeons made individual assessments of the fractures based on these. The assessment was conducted according to a systematic protocol including three classification systems (AO/Orthopaedic Trauma Association (OTA), Evans Jensen (EVJ), and Nakano) and questions addressing specific fracture patterns. An expert group provided a gold-standard assessment based on the CT images. Sensitivities and specificities of surgeons’ assessments were estimated and compared in regression models with correlations for the same patients. Intra- and inter-rater reliability were presented as Cohen’s kappa and Gwet’s agreement coefficient (AC1).Aims
Methods
The outcomes of patients with unexpected positive cultures (UPCs) during revision total hip arthroplasty (THA) and total knee arthroplasty (TKA) remain unknown. The objectives of this study were to establish the prevalence and infection-free implant survival in UPCs during presumed aseptic single-stage revision THA and TKA at mid-term follow-up. This study included 297 patients undergoing presumed aseptic single-stage revision THA or TKA at a single treatment centre. All patients with at least three UPCs obtained during revision surgery were treated with minimum three months of oral antibiotics following revision surgery. The prevalence of UPCs and causative microorganisms, the recurrence of periprosthetic joint infections (PJIs), and the infection-free implant survival were established at minimum five years’ follow-up (5.1 to 12.3).Aims
Methods
Computer-assisted 3D preoperative planning software has the potential to improve postoperative stability in total hip arthroplasty (THA). Commonly, preoperative protocols simulate two functional positions (standing and relaxed sitting) but do not consider other common positions that may increase postoperative impingement and possible dislocation. This study investigates the feasibility of simulating commonly encountered positions, and positions with an increased risk of impingement, to lower postoperative impingement risk in a CT-based 3D model. A robotic arm-assisted arthroplasty planning platform was used to investigate 11 patient positions. Data from 43 primary THAs were used for simulation. Sacral slope was retrieved from patient preoperative imaging, while angles of hip flexion/extension, hip external/internal rotation, and hip abduction/adduction for tested positions were derived from literature or estimated with a biomechanical model. The hip was placed in the described positions, and if impingement was detected by the software, inspection of the impingement type was performed.Aims
Methods
The purpose of this study is to report our updated results at a minimum follow-up of 30 years using a first generation uncemented tapered femoral component in primary total hip arthroplasty (THA). The original cohort consisted of 145 consecutive THAs performed by a single surgeon in 138 patients. A total of 37 patients (40 hips) survived a minimum of 30 years, and are the focus of this review. The femoral component used in all cases was a first-generation Taperloc with a non-modular 28 mm femoral head. Clinical follow-up at a minimum of 30 years was obtained on every living patient. Radiological follow-up at 30 years was obtained on all but four.Aims
Methods
The tibial component of total knee arthroplasty can either be an all-polyethylene (AP) implant or a metal-backed (MB) implant. This study aims to compare the five-year functional outcomes of AP tibial components to MB components in patients aged over 70 years. Secondary aims are to compare quality of life, implant survivorship, and cost-effectiveness. A group of 130 patients who had received an AP tibial component were matched for demographic factors of age, BMI, American Society of Anesthesiologists (ASA) grade, sex, and preoperative Knee Society Score (KSS) to create a comparison group of 130 patients who received a MB tibial component. Functional outcome was assessed prospectively by KSS, quality of life by 12-Item Short-Form Health Survey questionnaire (SF-12), and range of motion (ROM), and implant survivorships were compared. The SF six-dimension (6D) was used to calculate the incremental cost effectiveness ratio (ICER) for AP compared to MB tibial components using quality-adjusted life year methodology.Aims
Methods
United Classification System (UCS) B2 and B3 periprosthetic fractures in total hip arthroplasties (THAs) have been commonly managed with modular tapered stems. No study has evaluated the use of monoblock fluted tapered titanium stems for this indication. This study aimed to evaluate the effects of a monoblock stems on implant survivorship, postoperative outcomes, radiological outcomes, and osseointegration following treatment of THA UCS B2 and B3 periprosthetic fractures. A retrospective review was conducted of all patients who underwent revision THA (rTHA) for periprosthetic UCS B2 and B3 periprosthetic fracture who received a single design monoblock fluted tapered titanium stem at two large, tertiary care, academic hospitals. A total of 72 patients met inclusion and exclusion criteria (68 UCS B2, and four UCS B3 fractures). Primary outcomes of interest were radiological stem subsidence (> 5 mm), radiological osseointegration, and fracture union. Sub-analysis was also done for 46 patients with minimum one-year follow-up.Aims
Methods
We aim to evaluate the usefulness of postoperative blood tests by investigating the incidence of abnormal results following total joint replacement (TJR), as well as identifying preoperative risk factors for abnormal blood test results postoperatively, especially pertaining to anaemia and acute kidney injury (AKI). This is a retrospective cohort study of patients who had elective TJR between January and December 2019 at a tertiary centre. Data gathered included age at time of surgery, sex, BMI, American Society of Anesthesiologists (ASA) grade, preoperative and postoperative laboratory test results, haemoglobin (Hgb), white blood count (WBC), haematocrit (Hct), platelets (Plts), sodium (Na+), potassium (K+), creatinine (Cr), estimated glomerular filtration rate (eGFR), and Ferritin (ug/l). Abnormal blood tests, AKI, electrolyte imbalance, anaemia, transfusion, reoperation, and readmission within one year were reported.Aims
Methods
The aim of this study was to compare the functional and radiological outcomes and the complication rate after nail and plate fixation of unstable fractures of the ankle in elderly patients. In this multicentre study, 120 patients aged ≥ 60 years with an acute unstable AO/OTA type 44-B fracture of the ankle were randomized to fixation with either a nail or a plate and followed for 24 months after surgery. The primary outcome measure was the American Orthopaedic Foot and Ankle Society (AOFAS) Ankle-Hindfoot score. Secondary outcome measures were the Manchester-Oxford Foot Questionnaire, the Olerud and Molander Ankle score, the EuroQol five-dimension questionnaire, a visual analogue score for pain, complications, the quality of reduction of the fracture, nonunion, and the development of osteoarthritis.Aims
Methods
The aim of this study was to longitudinally compare the clinical and radiological outcomes of anatomical total shoulder arthroplasty (aTSA) up to long-term follow-up, when using cemented keel, cemented peg, and hybrid cage peg glenoid components and the same humeral system. We retrospectively analyzed a multicentre, international clinical database of a single platform shoulder system to compare the short-, mid-, and long-term clinical outcomes associated with three designs of aTSA glenoid components: 294 cemented keel, 527 cemented peg, and 981 hybrid cage glenoids. Outcomes were evaluated at 4,746 postoperative timepoints for 1,802 primary aTSA, with a mean follow-up of 65 months (24 to 217).Aims
Methods
The August 2023 Research Roundup360 looks at: Can artificial intelligence improve the readability of patient education materials?; What is the value of radiology input during a multidisciplinary orthopaedic oncology conference?; Periprosthetic joint infection in patients with multiple arthroplasties; Orthopedic Surgery and Anesthesiology Surgical Improvement Strategies Project - Phase III outcomes; Knot tying in arthroplasty and arthroscopy causes lesions to surgical gloves: a potential risk of infection; Vascular calcification of the ankle in plain radiographs equals diabetes mellitus?
The October 2023 Foot & Ankle Roundup360 looks at: Risk factors for failure of total ankle arthroplasties; Effects of synovial fluid fracture haematoma to tissue-engineered cartilage; Coronal plane deformity in CMT-cavovarus feet using automated 3D measurements; Immediate weightbearing after ankle fracture fixation – is it safe?; Unlocking the mystery of Mueller-Weiss disease; Diabetic foot management: predictors of failure.
The use of fluoroscopy in orthopaedic surgery creates risk of radiation exposure to surgeons. Appropriate personal protective equipment (PPE) can help mitigate this. The primary aim of this study was to assess if current radiation protection in orthopaedic trauma is safe. The secondary aims were to describe normative data of radiation exposure during common orthopaedic procedures, evaluate ways to improve any deficits in protection, and validate the use of electronic personal dosimeters (EPDs) in assessing radiation dose in orthopaedic surgery. Radiation exposure to surgeons during common orthopaedic trauma operations was prospectively assessed using EPDs and thermoluminescent dosimeters (TLDs). Normative data for each operation type were calculated and compared to recommended guidelines.Aims
Methods
Histology is widely used for diagnosis of persistent infection during reimplantation in two-stage revision hip and knee arthroplasty, although data on its utility remain scarce. Therefore, this study aims to assess the predictive value of permanent sections at reimplantation in relation to reinfection risk, and to compare results of permanent and frozen sections. We retrospectively collected data from 226 patients (90 hips, 136 knees) with periprosthetic joint infection who underwent two-stage revision between August 2011 and September 2021, with a minimum follow-up of one year. Histology was assessed via the SLIM classification. First, we analyzed whether patients with positive permanent sections at reimplantation had higher reinfection rates than patients with negative histology. Further, we compared permanent and frozen section results, and assessed the influence of anatomical regions (knee versus hip), low- versus high-grade infections, as well as first revision versus multiple prior revisions on the histological result at reimplantation. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), chi-squared tests, and Kaplan-Meier estimates were calculated.Aims
Methods
Posterior column plating through the single anterior approach reduces the morbidity in acetabular fractures that require stabilization of both the columns. The aim of this study is to assess the effectiveness of posterior column plating through the anterior intrapelvic approach (AIP) in the management of acetabular fractures. We retrospectively reviewed the data from R G Kar Medical College, Kolkata, India, from June 2018 to April 2023. Overall, there were 34 acetabulum fractures involving both columns managed by medial buttress plating of posterior column. The posterior column of the acetabular fracture was fixed through the AIP approach with buttress plate on medial surface of posterior column. Mean follow-up was 25 months (13 to 58). Accuracy of reduction and effectiveness of this technique were measured by assessing the Merle d’Aubigné score and Matta’s radiological grading at one year and at latest follow-up.Aims
Methods
The Vantage Total Ankle System is a fourth-generation low-profile fixed-bearing implant that has been available since 2016. We aimed to describe our early experience with this implant. This is a single-centre retrospective review of patients who underwent primary total ankle arthroplasty (TAA) with a Vantage implant between November 2017 and February 2020, with a minimum of two years’ follow-up. Four surgeons contributed patients. The primary outcome was reoperation and revision rate of the Vantage implant at two years. Secondary outcomes included radiological alignment, peri-implant complications, and pre- and postoperative patient-reported outcomes.Aims
Methods
The aim of this study was to gain a consensus for best practice of the assessment and management of children with idiopathic toe walking (ITW) in order to provide a benchmark for practitioners and guide the best consistent care. An established Delphi approach with predetermined steps and degree of agreement based on a standardized protocol was used to determine consensus. The steering group members and Delphi survey participants included members from the British Society of Children’s Orthopaedic Surgery (BSCOS) and the Association of Paediatric Chartered Physiotherapists (APCP). The statements included definition, assessment, treatment indications, nonoperative and operative interventions, and outcomes. Descriptive statistics were used for analysis of the Delphi survey results. The AGREE checklist was followed for reporting the results.Aims
Methods
The June 2023 Wrist & Hand Roundup360 looks at: Residual flexion deformity after scaphoid nonunion surgery: a seven-year follow-up study; The effectiveness of cognitive behavioural therapy for patients with concurrent hand and psychological disorders; Bite injuries to the hand and forearm: analysis of hospital stay, treatment, and costs; Outcomes of acute perilunate injuries - a systematic review; Abnormal MRI signal intensity of the triangular fibrocartilage complex in asymptomatic wrists; Patient comprehension of operative instructions with a paper handout versus a video: a prospective, randomized controlled trial; Can common hand surgeries be undertaken in the office setting?; The effect of corticosteroid injections on postoperative infections in trigger finger release.
The study aimed to assess the clinical outcomes of arthroscopic debridement and partial excision in patients with traumatic central tears of the triangular fibrocartilage complex (TFCC), and to identify prognostic factors associated with unfavourable clinical outcomes. A retrospective analysis was conducted on patients arthroscopically diagnosed with Palmer 1 A lesions who underwent arthroscopic debridement and partial excision from March 2009 to February 2021, with a minimum follow-up of 24 months. Patients were assessed using the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire, Mayo Wrist Score (MWS), and visual analogue scale (VAS) for pain. The poor outcome group was defined as patients whose preoperative and last follow-up clinical score difference was less than the minimal clinically important difference of the DASH score (10.83). Baseline characteristics, arthroscopic findings, and radiological factors (ulnar variance, MRI, or arthrography) were evaluated to predict poor clinical outcomes.Aims
Methods
The December 2022 Foot & Ankle Roundup360 looks at: Evans calcaneal osteotomy and multiplanar correction in flat foot deformity; Inflammatory biomarkers in tibialis posterior tendon dysfunction; Takedown of ankle fusions and conversion to total ankle arthroplasty; Surgical incision closure with three different materials; Absorbable sutures are not inferior to nonabsorbable sutures for tendo Achilles repair; Zadek’s osteotomy is a reliable technique for treating Haglund’s syndrome; How to best assess patient limitations after acute Achilles tendon injury; Advances in the management of infected nonunion of the foot and ankle.
The June 2023 Foot & Ankle Roundup360 looks at: Nail versus plate fixation for ankle fractures; Outcomes of first ray amputation in diabetic patients; Vascular calcification on plain radiographs of the ankle to diagnose diabetes mellitus; Elderly patients with ankle fracture: the case for early weight-bearing; Active treatment for Frieberg’s disease: does it work?; Survival of ankle arthroplasty; Complications following ankle arthroscopy.
Using data from the Hip Fracture Evaluation with Alternatives of Total Hip Arthroplasty versus Hemiarthroplasty (HEALTH) trial, we sought to determine if a difference in functional outcomes exists between monopolar and bipolar hemiarthroplasty (HA). This study is a secondary analysis of patients aged 50 years or older with a displaced femoral neck fracture who were enrolled in the HEALTH trial and underwent monopolar and bipolar HA. Scores from the Western Ontario and McMaster University Arthritis Index (WOMAC) and 12-Item Short Form Health Survey (SF-12) Physical Component Summary (PCS) and (MCS) were compared between the two HA groups using a propensity score-weighted analysis.Aims
Methods
We compared the risks of re-revision and mortality between two-stage and single-stage revision surgeries among patients with infected primary hip arthroplasty. Patients with a periprosthetic joint infection (PJI) of their primary arthroplasty revised with single-stage or two-stage procedure in England and Wales between 2003 and 2014 were identified from the National Joint Registry. We used Poisson regression with restricted cubic splines to compute hazard ratios (HRs) at different postoperative periods. The total number of revisions and re-revisions undergone by patients was compared between the two strategies.Aims
Methods
There is little information in the literature about the use of dual-mobility (DM) bearings in preventing re-dislocation in revision total hip arthroplasty (THA). The aim of this study was to compare the use of DM bearings, standard bearings, and constrained liners in revision THA for recurrent dislocation, and to identify risk factors for re-dislocation. We reviewed 86 consecutive revision THAs performed for dislocation between August 2012 and July 2019. A total of 38 revisions (44.2%) involved a DM bearing, while 39 (45.3%) and nine (10.5%) involved a standard bearing and a constrained liner, respectively. Rates of re-dislocation, re-revision for dislocation, and overall re-revision were compared. Radiographs were assessed for the positioning of the acetabular component, the restoration of the centre of rotation, leg length, and offset. Risk factors for re-dislocation were determined by Cox regression analysis. The modified Harris Hip Scores (mHHSs) were recorded. The mean age of the patients at the time of revision was 70 years (43 to 88); 54 were female (62.8%). The mean follow-up was 5.0 years (2.0 to 8.75).Aims
Methods
To perform an incremental cost-utility analysis and assess the impact of differential costs and case volume on the cost-effectiveness of robotic arm-assisted unicompartmental knee arthroplasty (rUKA) compared to manual (mUKA). This was a five-year follow-up study of patients who were randomized to rUKA (n = 64) or mUKA (n = 65). Patients completed the EuroQol five-dimension questionnaire (EQ-5D) preoperatively, and at three months and one, two, and five years postoperatively, which was used to calculate quality-adjusted life years (QALYs) gained. Costs for the primary and additional surgery and healthcare costs were calculated.Aims
Methods
Olecranon fractures are usually caused by falling directly on to the olecranon or following a fall on to an outstretched arm. Displaced fractures of the olecranon with a stable ulnohumeral joint are commonly managed by open reduction and internal fixation. The current predominant method of management of simple displaced fractures with ulnohumeral stability (Mayo grade IIA) in the UK and internationally is a low-cost technique using tension band wiring. Suture or suture anchor techniques have been described with the aim of reducing the hardware related complications and reoperation. An all-suture technique has been developed to fix the fracture using strong synthetic sutures alone. The aim of this trial is to investigate the clinical and cost-effectiveness of tension suture repair versus traditional tension band wiring for the surgical fixation of Mayo grade IIA fractures of the olecranon. SOFFT is a multicentre, pragmatic, two-arm parallel-group, non-inferiority, randomized controlled trial. Participants will be assigned 1:1 to receive either tension suture fixation or tension band wiring. 280 adult participants will be recruited. The primary outcome will be the Disabilities of the Arm, Shoulder and Hand (DASH) score at four months post-randomization. Secondary outcome measures include DASH (at 12, 18, and 24 months), pain, Net Promotor Score (patient satisfaction), EuroQol five-dimension five-level score (EQ-5D-5L), radiological union, complications, elbow range of motion, and re-operations related to the injury or to remove metalwork. An economic evaluation will assess the cost-effectiveness of treatments.Aims
Methods
Periprosthetic fractures (PPFs) following hip arthroplasty are complex injuries. This study evaluates patient demographic characteristics, management, outcomes, and risk factors associated with PPF subtypes over a decade. Using a multicentre collaborative study design, independent of registry data, we identified adults from 29 centres with PPFs around the hip between January 2010 and December 2019. Radiographs were assessed for the Unified Classification System (UCS) grade. Patient and injury characteristics, management, and outcomes were compared between UCS grades. A multinomial logistic regression was performed to estimate relative risk ratios (RRR) of variables on UCS grade.Aims
Methods
The aim of this study was to compare open reduction and internal fixation (ORIF) with revision surgery for the surgical management of Unified Classification System (UCS) type B periprosthetic femoral fractures around cemented polished taper-slip femoral components following primary total hip arthroplasty (THA). Data were collected for patients admitted to five UK centres. The primary outcome measure was the two-year reoperation rate. Secondary outcomes were time to surgery, transfusion requirements, critical care requirements, length of stay, two-year local complication rates, six-month systemic complication rates, and mortality rates. Comparisons were made by the form of treatment (ORIF vs revision) and UCS type (B1 vs B2/B3). Kaplan-Meier survival analysis was performed with two-year reoperation for any reason as the endpoint.Aims
Methods
Achieving accurate implant positioning and restoring native hip biomechanics are key surgeon-controlled technical objectives in total hip arthroplasty (THA). The primary objective of this study was to compare the reproducibility of the planned preoperative centre of hip rotation (COR) in patients undergoing robotic arm-assisted THA versus conventional THA. This prospective randomized controlled trial (RCT) included 60 patients with symptomatic hip osteoarthritis undergoing conventional THA (CO THA) versus robotic arm-assisted THA (RO THA). Patients in both arms underwent pre- and postoperative CT scans, and a patient-specific plan was created using the robotic software. The COR, combined offset, acetabular orientation, and leg length discrepancy were measured on the pre- and postoperative CT scanogram at six weeks following surgery.Aims
Methods
Pelvic discontinuity is a rare but increasingly common complication of total hip arthroplasty (THA). This single-centre study evaluated the performance of custom-made triflange acetabular components in acetabular reconstruction with pelvic discontinuity by determining: 1) revision and overall implant survival rates; 2) discontinuity healing rate; and 3) Harris Hip Score (HHS). Retrospectively collected data of 38 patients (39 hips) with pelvic discontinuity treated with revision THA using a custom-made triflange acetabular component were analyzed. Minimum follow-up was two years (mean 5.1 years (2 to 11)).Aims
Methods
Ankle fracture is one of the most common musculoskeletal injuries sustained in the UK. Many patients experience pain and physical impairment, with the consequences of the fracture and its management lasting for several months or even years. The broad aim of ankle fracture treatment is to maintain the alignment of the joint while the fracture heals, and to reduce the risks of problems, such as stiffness. More severe injuries to the ankle are routinely treated surgically. However, even with advances in surgery, there remains a risk of complications; for patients experiencing these, the associated loss of function and quality of life (Qol) is considerable. Non-surgical treatment is an alternative to surgery and involves applying a cast carefully shaped to the patient’s ankle to correct and maintain alignment of the joint with the key benefit being a reduction in the frequency of common complications of surgery. The main potential risk of non-surgical treatment is a loss of alignment with a consequent reduction in ankle function. This study aims to determine whether ankle function, four months after treatment, in patients with unstable ankle fractures treated with close contact casting is not worse than in those treated with surgical intervention, which is the current standard of care. This trial is a pragmatic, multicentre, randomized non-inferiority clinical trial with an embedded pilot, and with 12 months clinical follow-up and parallel economic analysis. A surveillance study using routinely collected data will be performed annually to five years post-treatment. Adult patients, aged 60 years and younger, with unstable ankle fractures will be identified in daily trauma meetings and fracture clinics and approached for recruitment prior to their treatment. Treatments will be performed in trauma units across the UK by a wide range of surgeons. Details of the surgical treatment, including how the operation is done, implant choice, and the recovery programme afterwards, will be at the discretion of the treating surgeon. The non-surgical treatment will be close-contact casting performed under anaesthetic, a technique which has gained in popularity since the publication of the Ankle Injury Management (AIM) trial. In all, 890 participants (445 per group) will be randomly allocated to surgical or non-surgical treatment. Data regarding ankle function, QoL, complications, and healthcare-related costs will be collected at eight weeks, four and 12 months, and then annually for five years following treatment. The primary outcome measure is patient-reported ankle function at four months from treatment.Aims
Methods
The aim of this investigation was to compare risk of infection in both cemented and uncemented hemiarthroplasty (HA) as well as in total hip arthroplasty (THA) following femoral neck fracture. Data collection was performed using the German Arthroplasty Registry (EPRD). In HA and THA following femoral neck fracture, fixation method was divided into cemented and uncemented prostheses and paired according to age, sex, BMI, and the Elixhauser Comorbidity Index using Mahalanobis distance matching.Aims
Methods
Spinal anaesthesia has seen increased use in contemporary primary total knee arthroplasties (TKAs). However, controversy exists about the benefits of spinal in comparison to general anaesthesia in primary TKAs. This study aimed to investigate the pain control, length of stay (LOS), and complications associated with spinal versus general anaesthesia in primary TKAs from a single, high-volume academic centre. We retrospectively identified 17,690 primary TKAs (13,297 patients) from 2001 to 2016 using our institutional total joint registry, where 52% had general anaesthesia and 48% had spinal anaesthesia. Baseline characteristics were similar between cohorts with a mean age of 68 years (SD 10), 58% female (n = 7,669), and mean BMI of 32 kg/m2 (SD 7). Pain was evaluated using oral morphine equivalents (OMEs) and numerical pain rating scale (NPRS) data. Complications including 30- and 90-day readmissions were studied. Data were analyzed using an inverse probability of treatment weighted model based on propensity score that included many patient and surgical factors. Mean follow-up was seven years (2 to 18).Aims
Methods
Valgus knee deformity can present a number of
unique surgical challenges for the total knee arthroplasty (TKA)
surgeon. Understanding the typical patterns of bone and soft-tissue pathology
in the valgus arthritic knee is critical for appropriate surgical
planning. This review aims to provide the knee arthroplasty surgeon
with an understanding of surgical management strategies for the
treatment of valgus knee arthritis. Lateral femoral and tibial deficiencies, contracted lateral soft
tissues, attenuated medial soft tissues, and multiplanar deformities
may all be present in the valgus arthritic knee. A number of classifications
have been reported in order to guide surgical management, and a variety
of surgical strategies have been described with satisfactory clinical
results. Depending on the severity of the deformity, a variety of
TKA implant designs may be appropriate for use. Regardless of an
The purpose of this study was to determine the weightbearing practice of operatively managed fragility fractures in the setting of publically funded health services in the UK and Ireland. The Fragility Fracture Postoperative Mobilisation (FFPOM) multicentre audit included all patients aged 60 years and older undergoing surgery for a fragility fracture of the lower limb between 1 January 2019 and 30 June 2019, and 1 February 2021 and 14 March 2021. Fractures arising from high-energy transfer trauma, patients with multiple injuries, and those associated with metastatic deposits or infection were excluded. We analyzed this patient cohort to determine adherence to the British Orthopaedic Association Standard, “all surgery in the frail patient should be performed to allow full weight-bearing for activities required for daily livingAims
Methods
The aim of this study was to investigate the rate of revision for distal femoral arthroplasty (DFA) performed as a primary procedure for native knee fractures using data from the Australian Orthopaedic Association National Joint Arthroplasty Registry (AOANJRR). Data from the AOANJRR were obtained for DFA performed as primary procedures for native knee fractures from 1 September 1999 to 31 December 2020. Pathological fractures and revision for failed internal fixation were excluded. The five prostheses identified were the Global Modular Arthroplasty System, the Modular Arthroplasty System, the Modular Universal Tumour And Revision System, the Orthopaedic Salvage System, and the Segmental System. Patient demographic data (age, sex, and American Society of Anesthesiologists grade) were obtained, where available. Kaplan-Meier estimates of survival were used to determine the rate of revision, and the reasons for revision and mortality data were examined.Aims
Methods
Meniscal allograft transplantation (MAT) for patients with symptomatic meniscal loss has demonstrated good clinical results and survivorship. Factors that affect both functional outcome and survivorship have been reported in the literature. These are typically single-centre case series with relatively small numbers and conflicting results. Our aim was to describe an international, two-centre case series, and identify factors that affect both functional outcome and survival. We report factors that affect outcome on 526 patients undergoing MAT across two sites (one in the UK and one in Italy). Outcomes of interest were the Knee injury and Osteoarthritis Outcome Score four (KOOS4) at two years and failure rates. We performed multiple regression analysis to examine for factors affecting KOOS, and Cox proportional hazards models for survivorship.Aims
Methods
We present the results of 90 consecutive children with displaced fractures of the forearm treated by elastic stable intramedullary nailing with a mean follow-up of 6.6 months (2.0 to 17.6). Eight (9%) had open fractures and 77 (86%) had sustained a fracture of both bones. The operations were performed by orthopaedic trainees in 78 patients (86%). All fractures healed at a mean of 2.9 months (1.1 to 8.7). There was one case of delayed union of an ulnar fracture. An excellent or good functional outcome was achieved in 76 patients (84%). There was no statistical difference detected when the grade of
Periprosthetic joint infection (PJI) occurs in approximately 1% to 2% of total knee arthroplasties (TKA) presenting multiple challenges, such as difficulty in diagnosis, technical complexity, and financial costs. Two-stage exchange is the gold standard for treating PJI but emerging evidence suggests 'two-in-one' single-stage revision as an alternative, delivering comparable outcomes, reduced morbidity, and cost-effectiveness. This study investigates five-year results of modified single-stage revision for treatment of PJI following TKA with bone loss. Patients were identified from prospective data on all TKA patients with PJI following the primary procedure. Inclusion criteria were: revision for PJI with bone loss requiring reconstruction, and a minimum five years’ follow-up. Patients were followed up for recurrent infection and assessment of function. Tools used to assess function were Oxford Knee Score (OKS) and American Knee Society Score (AKSS).Aims
Methods
In UK there are around 76,000 hip fractures occur each year 10% to 15% of which are undisplaced intracapsular. There is considerable debate whether internal fixation is the most appropriate treatment for undisplaced fractures in older patients. This study describes cannulated hip screws survivorship analysis for patients aged ≥ 60 years with undisplaced intra-capsular fractures. This was a retrospective cohort study of consecutive patients aged ≥ 60 years who had cannulated screws fixation for Garden I and II fractures in a teaching hospital between March 2013 and March 2016. The primary outcome was further same-side hip surgery. Descriptive statistics were used and Kaplan-Meier estimates calculated for implant survival.Aims
Methods
The aim of this study was to determine if uncemented acetabular polyethylene (PE) liner geometry, and lip size, influenced the risk of revision for instability or loosening. A total of 202,511 primary total hip arthroplasties (THAs) with uncemented acetabular components were identified from the National Joint Registry (NJR) dataset between 2003 and 2017. The effect of liner geometry on the risk of revision for instability or loosening was investigated using competing risk regression analyses adjusting for age, sex, American Society of Anesthesiologists grade, indication, side, institution type, surgeon grade, surgical approach, head size, and polyethylene crosslinking. Stratified analyses by surgical approach were performed, including pairwise comparisons of liner geometries.Aims
Methods
Metal-on-metal hip resurfacing was performed for developmental dysplasia in 96 hips in 85 patients, 78 in women and 18 in men, with a mean age at the time of surgery of 43 years (14 to 65). These cases were matched for age, gender,
Psychoeducative prehabilitation to optimize surgical outcomes is relatively novel in spinal fusion surgery and, like most rehabilitation treatments, they are rarely well specified. Spinal fusion patients experience anxieties perioperatively about pain and immobility, which might prolong hospital length of stay (LOS). The aim of this prospective cohort study was to determine if a Preoperative Spinal Education (POSE) programme, specified using the Rehabilitation Treatment Specification System (RTSS) and designed to normalize expectations and reduce anxieties, was safe and reduced LOS. POSE was offered to 150 prospective patients over ten months (December 2018 to November 2019) Some chose to attend (Attend-POSE) and some did not attend (DNA-POSE). A third independent retrospective group of 150 patients (mean age 57.9 years (SD 14.8), 50.6% female) received surgery prior to POSE (pre-POSE). POSE consisted of an in-person 60-minute education with accompanying literature, specified using the RTSS as psychoeducative treatment components designed to optimize cognitive/affective representations of thoughts/feelings, and normalize anxieties about surgery and its aftermath. Across-group age, sex, median LOS, perioperative complications, and readmission rates were assessed using appropriate statistical tests.Aims
Methods
Balancing service provision and surgical training is a challenging issue that affects all healthcare systems. A multicentre prospective study of 1501 total hip replacements was undertaken to investigate whether there is an association between surgical outcome and the grade of the
To establish the survivorship, function, and metal ion levels in an unselected series of metal-on-metal hip resurfacing arthroplasties (HRAs) performed by a non-designer surgeon. We reviewed 105 consecutive HRAs in 83 patients, performed by a single surgeon, at a mean follow-up of 14.9 years (9.3 to 19.1). The cohort included 45 male and 38 female patients, with a mean age of 49.5 years (SD 12.5)Aims
Methods
Single-shot adductor canal block (ACB) after total knee arthroplasty (TKA) for postoperative analgesia is a common modality. Patients can experience breakthrough pain when the effect of ACB wears off. Local anaesthetic infusion through an intra-articular catheter (IAC) can help manage breakthrough pain after TKA. We hypothesized that combined ACB with ropivacaine infusion through IAC is associated with better pain relief compared to ACB used alone. This study was a prospective double-blinded placebo-controlled randomized controlled trial to compare the efficacy of combined ACB+ IAC-ropivacaine infusion (study group, n = 68) versus single-shot ACB+ intra-articular normal saline placebo (control group, n = 66) after primary TKA. The primary outcome was assessment of pain, using the visual analogue scale (VAS) recorded at 6, 12, 24, and 48 hours after surgery. Secondary outcomes included active knee ROM 48 hours after surgery and additional requirement of analgesia for breakthrough pain.Aims
Methods
The modified Radiological Union Scale for Tibia (mRUST) fractures score was developed in order to assess progress to union and define a numerical assessment of fracture healing of metadiaphyseal fractures. This score has been shown to be valuable in predicting radiological union; however, there is no information on the sensitivity, specificity, and accuracy of this index for various cut-off scores. The aim of this study is to evaluate sensitivity, specificity, accuracy, and cut-off points of the mRUST score for the diagnosis of metadiaphyseal fractures healing. A cohort of 146 distal femur fractures were retrospectively identified at our institution. After excluding AO/OTA type B fractures, nonunions, follow-up less than 12 weeks, and patients aged less than 16 years, 104 sets of radiographs were included for analysis. Anteroposterior and lateral femur radiographs at six weeks, 12 weeks, 24 weeks, and final follow-up were separately scored by three surgeons using the mRUST score. The sensitivity and specificity of mean mRUST score were calculated using clinical and further radiological findings as a gold standard for ultimate fracture healing. A receiver operating characteristic curve was also performed to determine the cut-off points at each time point.Aims
Methods
The primary objective of this study was to compare the postoperative infection rate between negative pressure wound therapy (NPWT) and conventional dressings for closed incisions following soft-tissue sarcoma (STS) surgery. Secondary objectives were to compare rates of adverse wound events and functional scores. In this prospective, single-centre, randomized controlled trial (RCT), patients were randomized to either NPWT or conventional sterile occlusive dressings. A total of 17 patients, with a mean age of 54 years (21 to 81), were successfully recruited and none were lost to follow-up. Wound reviews were undertaken to identify any surgical site infection (SSI) or adverse wound events within 30 days. The Toronto Extremity Salvage Score (TESS) and Musculoskeletal Tumor Society (MSTS) score were recorded as patient-reported outcome measures (PROMs).Aims
Methods
Deep surgical site infection (SSI) remains an unsolved problem after hip fracture. Debridement, antibiotic, and implant retention (DAIR) has become a mainstream treatment in elective periprosthetic joint infection; however, evidence for DAIR after infected hip hemiarthroplaty is limited. Patients who underwent a hemiarthroplasty between March 2007 and August 2018 were reviewed. Multivariable binary logistic regression was performed to identify and adjust for risk factors for SSI, and to identify factors predicting a successful DAIR at one year.Aims
Methods
The aims of this study were to compare clinically relevant measurements of hip dysplasia on radiographs taken in the supine and standing position, and to compare Hip2Norm software and Picture Archiving and Communication System (PACS)-derived digital radiological measurements. Preoperative supine and standing radiographs of 36 consecutive patients (43 hips) who underwent periacetabular osteotomy surgery were retrospectively analyzed from a single-centre, two-surgeon cohort. Anterior coverage (AC), posterior coverage (PC), lateral centre-edge angle (LCEA), acetabular inclination (AI), sharp angle (SA), pelvic tilt (PT), retroversion index (RI), femoroepiphyseal acetabular roof (FEAR) index, femoroepiphyseal horizontal angle (FEHA), leg length discrepancy (LLD), and pelvic obliquity (PO) were analyzed using both Hip2Norm software and PACS-derived measurements where applicable.Aims
Methods
This study aimed to evaluate the accuracy of implant placement with robotic-arm assisted total hip arthroplasty (THA) in patients with developmental dysplasia of the hip (DDH). The study analyzed a consecutive series of 69 patients who underwent robotic-arm assisted THA between September 2018 and December 2019. Of these, 30 patients had DDH and were classified according to the Crowe type. Acetabular component alignment and 3D positions were measured using pre- and postoperative CT data. The absolute differences of cup alignment and 3D position were compared between DDH and non-DDH patients. Moreover, these differences were analyzed in relation to the severity of DDH. The discrepancy of leg length and combined offset compared with contralateral hip were measured.Aims
Methods
Elective orthopaedic services have had to adapt to significant system-wide pressures since the emergence of COVID-19 in December 2019. Length of stay is often recognized as a key marker of quality of care in patients undergoing arthroplasty. Expeditious discharge is key in establishing early rehabilitation and in reducing infection risk, both procedure-related and from COVID-19. The primary aim was to determine the effects of the COVID-19 pandemic length of stay following hip and knee arthroplasty at a high-volume, elective orthopaedic centre. A retrospective cohort study was performed. Patients undergoing primary or revision hip or knee arthroplasty over a six-month period, from 1 July to 31 December 2020, were compared to the same period in 2019 before the COVID-19 pandemic. Demographic data, American Society of Anesthesiologists (ASA) grade, wait to surgery, COVID-19 status, and length of hospital stay were recorded.Aims
Methods
This aim of this study was to assess the reliability and validity of the Unified Classification System (UCS) for postoperative periprosthetic femoral fractures (PFFs) around cemented polished taper-slip (PTS) stems. Radiographs of 71 patients with a PFF admitted consecutively at two centres between 25 February 2012 and 19 May 2020 were collated by an independent investigator. Six observers (three hip consultants and three trainees) were familiarized with the UCS. Each PFF was classified on two separate occasions, with a mean time between assessments of 22.7 days (16 to 29). Interobserver reliability for more than two observers was assessed using percentage agreement and Fleiss’ kappa statistic. Intraobserver reliability between two observers was calculated with Cohen kappa statistic. Validity was tested on surgically managed UCS type B PFFs where stem stability was documented in operation notes (n = 50). Validity was assessed using percentage agreement and Cohen kappa statistic between radiological assessment and intraoperative findings. Kappa statistics were interpreted using Landis and Koch criteria. All six observers were blinded to operation notes and postoperative radiographs.Aims
Methods
It is important to understand the rate of complications associated with the increasing burden of revision shoulder arthroplasty. Currently, this has not been well quantified. This review aims to address that deficiency with a focus on complication and reoperation rates, shoulder outcome scores, and comparison of anatomical and reverse prostheses when used in revision surgery. A Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) systematic review was performed to identify clinical data for patients undergoing revision shoulder arthroplasty. Data were extracted from the literature and pooled for analysis. Complication and reoperation rates were analyzed using a meta-analysis of proportion, and continuous variables underwent comparative subgroup analysis.Aims
Methods
A pragmatic multicentre randomized controlled trial, UK FROzen Shoulder Trial (UK FROST), was conducted in the UK NHS comparing the cost-effectiveness of commonly used treatments for adults with primary frozen shoulder in secondary care. A cost utility analysis from the NHS perspective was performed. Differences between manipulation under anaesthesia (MUA), arthroscopic capsular release (ACR), and early structured physiotherapy plus steroid injection (ESP) in costs (2018 GBP price base) and quality adjusted life years (QALYs) at one year were used to estimate the cost-effectiveness of the treatments using regression methods.Aims
Methods
A prospective cohort of 222 patients who underwent revision hip replacement between April 2001 and March 2004 was evaluated to determine predictors of function, pain and activity level between one and two years post-operatively, and to define quality of life outcomes using validated patient reported outcome tools. Predictive models were developed and proportional odds regression analyses were performed to identify factors that predict quality of life outcomes at one and two years post-operatively. The dependent outcome variables were the Western Ontario and McMaster Osteoarthritis Index (WOMAC) function and pain scores, and University of California Los Angeles activity scores. The independent variables included patient demographics, operative factors, and objective quality of life parameters, including pre-operative WOMAC, and the Short Form-12 mental component score. There was a significant improvement (t-test, p <
0.001) in all patient quality of life scores. In the predictive model, factors predictive of improved function (original regression analyses, p <
0.05) included a higher pre-operative WOMAC function score (p <
0.001), age between 60 and 70 years (p <
0.037), male gender (p = 0.017), lower Charnley class (p <
0.001) and aseptic loosening being the indication for revision (p <
0.003). Using the WOMAC pain score as an outcome variable, factors predictive of improvement included the pre-operative WOMAC function score (p = 0.001), age between 60 and 70 years (p = 0.004), male gender (p = 0.005), lower Charnley class (p = 0.001) and no previous revision procedure (p = 0.023). The pre-operative WOMAC function score (p = 0.001), the indication for the operation (p = 0.007), and the
Bone stock restoration of acetabular bone defects using impaction bone grafting (IBG) in total hip arthroplasty may facilitate future re-revision in the event of failure of the reconstruction. We hypothesized that the acetabular bone defect during re-revision surgery after IBG was smaller than during the previous revision surgery. The clinical and radiological results of re-revisions with repeated use of IBG were also analyzed. In a series of 382 acetabular revisions using IBG and a cemented component, 45 hips (45 patients) that had failed due to aseptic loosening were re-revised between 1992 and 2016. Acetabular bone defects graded according to Paprosky during the first and the re-revision surgery were compared. Clinical and radiological findings were analyzed over time. Survival analysis was performed using a competing risk analysis.Aims
Methods
The aim of this study was to radiologically evaluate the quality of cement mantle and alignment achieved with a polished tapered cemented femoral stem inserted through the anterior approach and compared with the posterior approach. A comparative retrospective study of 115 consecutive hybrid total hip arthroplasties or cemented hemiarthroplasties in 110 patients, performed through anterior (n = 58) or posterior approach (n = 57) using a collarless polished taper-slip femoral stem, was conducted. Cement mantle quality and thickness were assessed in both planes. Radiological outcomes were compared between groups.Aims
Methods
We aimed to investigate if the use of the largest possible cobalt-chromium head articulating with polyethylene acetabular inserts would increase the in vivo wear rate in total hip arthroplasty. In a single-blinded randomized controlled trial, 96 patients (43 females), at a median age of 63 years (interquartile range (IQR) 57 to 69), were allocated to receive either the largest possible modular femoral head (36 mm to 44 mm) in the thinnest possible insert or a standard 32 mm head. All patients received a vitamin E-doped cross-linked polyethylene insert and a cobalt-chromium head. The primary outcome was proximal head penetration measured with radiostereometric analysis (RSA) at two years. Secondary outcomes were volumetric wear, periacetabular radiolucencies, and patient-reported outcomes.Aims
Methods
The anteroposterior stability of cadaveric knees was investigated. There was a wide range of normal laxity; knees were more stable at 90 degrees than at 20 degrees flexion. Anterior cruciate ligament implants with different stiffnesses were inserted; normal stability could always be restored, and the stiffness or extensibility of implants did not affect knee behaviour significantly. The tightness of implants was critical--small tensioning errors caused subluxation, inhibited knee extension and allowed damagingly high implant tensions. It is concluded that the tension of ligament implants could not be adjusted simply with a pre-set instrument; the procedure will remain critically dependent on the judgment of the
We retrospectively studied the major complications occurring after one- and two-stage bilateral unicompartmental knee replacements (UKR). Between 1999 and 2008, 911 patients underwent 1150 UKRs through a minimally invasive approach in our unit. Of these, 159 patients (318 UKRs) had one-stage and 80 patients (160 UKRs) had two-stage bilateral UKRs. The bilateral UKR groups were comparable in age and American Society of Anaesthesiology grade, but more women were in the two-stage group (p = 0.019). Mechanical thromboprophylaxis was used in all cases. Major complications were recorded as death, pulmonary embolus, proximal deep-vein thrombosis and adverse cardiac events within 30 days of surgery. No statistical differences between the groups were found regarding the
Surgical treatment of hip fracture is challenging; the bone is porotic and fixation failure can be catastrophic. Novel implants are available which may yield superior clinical outcomes. This study compared the clinical effectiveness of the novel X-Bolt Hip System (XHS) with the sliding hip screw (SHS) for the treatment of fragility hip fractures. We conducted a multicentre, superiority, randomized controlled trial. Patients aged 60 years and older with a trochanteric hip fracture were recruited in ten acute UK NHS hospitals. Participants were randomly allocated to fixation of their fracture with XHS or SHS. A total of 1,128 participants were randomized with 564 participants allocated to each group. Participants and outcome assessors were blind to treatment allocation. The primary outcome was the EuroQol five-dimension five-level health status (EQ-5D-5L) utility at four months. The minimum clinically important difference in utility was pre-specified at 0.075. Secondary outcomes were EQ-5D-5L utility at 12 months, mortality, residential status, mobility, revision surgery, and radiological measures.Aims
Methods
Unicompartmental knee arthroplasty (UKA) is a bone-preserving treatment option for osteoarthritis localized to a single compartment in the knee. The success of the procedure is sensitive to patient selection and alignment errors. Robotic arm-assisted UKA provides technological assistance to intraoperative bony resection accuracy, which is thought to improve ligament balancing. This paper presents the five-year outcomes of a comparison between manual and robotically assisted UKAs. The trial design was a prospective, randomized, parallel, single-centre study comparing surgical alignment in patients undergoing UKA for the treatment of medial compartment osteoarthritis (ISRCTN77119437). Participants underwent surgery using either robotic arm-assisted surgery or conventional manual instrumentation. The primary outcome measure (surgical accuracy) has previously been reported, and, along with secondary outcomes, were collected at one-, two-, and five-year timepoints. Analysis of five-year results and longitudinal analysis for all timepoints was performed to compare the two groups.Aims
Methods
The aim of this study was to determine the diagnostic accuracy of α defensin (AD) lateral flow assay (LFA) and enzyme-linked immunosorbent assay (ELISA) tests for periprosthetic joint infection (PJI) in comparison to conventional synovial white blood cell (WBC) count and polymorphonuclear neutrophil percentage (PMN%) analysis. Patients undergoing joint aspiration for evaluation of pain after total knee arthroplasty (TKA) or total hip arthroplasty (THA) were considered for inclusion. Synovial fluids from 99 patients (25 THA and 74 TKA) were analyzed by WBC count and PMN% analysis, AD LFA, and AD ELISA. WBC and PMN% cutoffs of ≥ 1,700 cells/mm3 and ≥ 65% for TKA and ≥ 3,000 cells/mm3 and ≥ 80% for THA were used, respectively. A panel of three physicians, all with expertise in orthopaedic infections and who were blinded to the results of AD tests, independently reviewed patient data to diagnose subjects as with or without PJI. Consensus PJI classification was used as the reference standard to evaluate test performances. Results were compared using McNemar’s test and area under the receiver operating characteristic curve (AUC) analysis.Aims
Methods
We performed a prospective, randomised study comparing the rates of glove perforation using double latex gloving with or without a disposable protective glove liner (Paraderm) on 118 patients undergoing primary or revision arthroplasty of the hip or knee by one surgeon (FRH). The patients were randomly allocated into two groups: in group 1 an inner and outer pair of latex gloves were worn as double gloves and in group 2 the glove liner was worn between the two latex gloves. There was glove perforation in at least one outer glove in 99 operations (84%). The
The objective of this study was to compare the two-year migration pattern and clinical outcomes of a total knee arthroplasty (TKA) with an asymmetrical tibial design (Persona PS) and a well-proven TKA with a symmetrical tibial design (NexGen LPS). A randomized controlled radiostereometric analysis (RSA) trial was conducted including 75 cemented posterior-stabilized TKAs. Implant migration was measured with RSA. Maximum total point motion (MTPM), translations, rotations, clinical outcomes, and patient-reported outcome measures (PROMs) were assessed at one week postoperatively and at three, six, 12, and 24 months postoperatively.Aims
Methods
The aim of this prospective cohort study was to evaluate the early migration of the TriFit cementless proximally coated tapered femoral stem using radiostereometric analysis (RSA). A total of 21 patients (eight men and 13 women) undergoing primary total hip arthroplasty (THA) for osteoarthritis of the hip were recruited in this study and followed up for two years. Two patients were lost to follow-up. All patients received a TriFit stem and Trinity Cup with a vitamin E-infused highly cross-linked ultra-high molecular weight polyethylene liner. Radiographs for RSA were taken postoperatively and then at three, 12, and 24 months. Oxford Hip Score (OHS), EuroQol five-dimension questionnaire (EQ-5D), and adverse events were reported.Aims
Methods
To benchmark the radiation dose to patients during the course of treatment for a spinal deformity. Our radiation dose database identified 25,745 exposures of 6,017 children (under 18 years of age) and adults treated for a spinal deformity between 1 January 2008 and 31 December 2016. Patients were divided into surgical (974 patients) and non-surgical (5,043 patients) cohorts. We documented the number and doses of ionizing radiation imaging events (radiographs, CT scans, or intraoperative fluoroscopy) for each patient. All the doses for plain radiographs, CT scans, and intraoperative fluoroscopy were combined into a single effective dose by a medical physicist (milliSivert (mSv)).Aims
Methods
The British Spine Registry (BSR) was introduced in May 2012 to be used as a web-based database for spinal surgeries carried out across the UK. Use of this database has been encouraged but not compulsory, which has led to a variable level of engagement in the UK. In 2019 NHS England and NHS Improvement introduced a new Best Practice Tariff (BPT) to encourage input of spinal surgical data on the BSR. The aim of our study was to assess the impact of the spinal BPT on compliance with the recording of surgical data on the BSR. A retrospective review of data was performed at a tertiary spinal centre between 2018 to 2020. Data were collated from electronic patient records, theatre operating lists, and trust-specific BSR data. Information from the BSR included operative procedures (mandatory), patient consent, email addresses, and demographic details. We also identified Healthcare Resource Groups (HRGs) which qualified for BPT.Aims
Methods
Debate continues regarding the optimum management of periprosthetic distal femoral fractures (PDFFs). This study aims to determine which operative treatment is associated with the lowest perioperative morbidity and mortality when treating low (Su type II and III) PDFFs comparing lateral locking plate fixation (LLP-ORIF) or distal femoral arthroplasty (DFA). This was a retrospective cohort study of 60 consecutive unilateral (PDFFs) of Su types II (40/60) and III (20/60) in patients aged ≥ 60 years: 33 underwent LLP-ORIF (mean age 81.3 years (SD 10.5), BMI 26.7 (SD 5.5); 29/33 female); and 27 underwent DFA (mean age 78.8 years (SD 8.3); BMI 26.7 (SD 6.6); 19/27 female). The primary outcome measure was reoperation. Secondary outcomes included perioperative complications, calculated blood loss, transfusion requirements, functional mobility status, length of acute hospital stay, discharge destination and mortality. Kaplan-Meier survival analysis was performed. Cox multivariate regression analysis was performed to identify risk factors for reoperation after LLP-ORIF.Aims
Methods
From 1982 to 1987, we randomised prospectively 413 patients requiring primary total hip replacements to receive either a Stanmore or Charnley prosthesis. They were reviewed by an independent observer in an attempt to correlate a number of factors including femoral head size with longevity. There were 213 Stanmore hips and 200 Charnley prostheses. At five to ten years (mean 6.5) 76 patients had died and 16 arthroplasties had required revision. Seven were radiologically loose in asymptomatic patients. There was only one case of deep infection. We found no difference statistically in the clinical outcome or in the revision rate of 4% in the two types of prosthesis. The revision rate was greater for trainees than for senior
Removal of infected components and culture-directed antibiotics are important for the successful treatment of chronic periprosthetic joint infection (PJI). However, as many as 27% of chronic PJI patients yield negative culture results. Although culture negativity has been thought of as a contraindication to one-stage revision, data supporting this assertion are limited. The aim of our study was to report on the clinical outcomes for one-stage and two-stage exchange arthroplasty performed in patients with chronic culture-negative PJI. A total of 105 consecutive patients who underwent revision arthroplasty for chronic culture-negative PJI were retrospectively evaluated. One-stage revision arthroplasty was performed in 30 patients, while 75 patients underwent two-stage exchange, with a minimum of one year's follow-up. Reinfection, re-revision for septic and aseptic reasons, amputation, readmission, mortality, and length of stay were compared between the two treatment strategies.Aims
Methods
We aimed to address the question on whether there is a place for shoulder stabilization surgery in patients who had voluntary posterior instability starting in childhood and adolescence, and later becoming involuntary and uncontrollable. Consecutive patients who had an operation for recurrent posterior instability before the age of 18 years were studied retrospectively. All patients had failed conservative treatment for at least six months prior to surgery; and no patients had psychiatric disorders. Two groups were identified and compared: voluntary posterior instability starting in childhood which became uncontrollable and involuntary (group VBI); and involuntary posterior instability (group I). Patients were reviewed and assessed at least two years after surgery by two examiners.Aims
Methods
Patients receiving cemented hemiarthroplasties after hip fracture have a significant risk of deep surgical site infection (SSI). Standard UK practice to minimize the risk of SSI includes the use of antibiotic-loaded bone cement with no consensus regarding type, dose, or antibiotic content of the cement. This is the protocol for a randomized clinical trial to investigate the clinical and cost-effectiveness of high dose dual antibiotic-loaded cement in comparison to low dose single antibiotic-loaded cement in patients 60 years and over receiving a cemented hemiarthroplasty for an intracapsular hip fracture. The WHiTE 8 Copal Or Palacos Antibiotic Loaded bone cement trial (WHiTE 8 COPAL) is a multicentre, multi-surgeon, parallel, two-arm, randomized clinical trial. The pragmatic study will be embedded in the World Hip Trauma Evaluation (WHiTE) (ISRCTN 63982700). Participants, including those that lack capacity, will be allocated on a 1:1 basis stratified by recruitment centre to either a low dose single antibiotic-loaded bone cement or a high dose dual antibiotic-loaded bone cement. The primary analysis will compare the differences in deep SSI rate as defined by the Centers for Disease Control and Prevention within 90 days of surgery via medical record review and patient self-reported questionnaires. Secondary outcomes include UK Core Outcome Set for hip fractures, complications, rate of antibiotic prescription, resistance patterns of deep SSI, and resource use (more specifically, cost-effectiveness) up to four months post-randomization. A minimum of 4,920 patients will be recruited to obtain 90% power to detect an absolute difference of 1.5% in the rate of deep SSI at 90 days for the expected 3% deep SSI rate in the control group.Aims
Methods
A comprehensive classification for coronal lower limb alignment with predictive capabilities for knee balance would be beneficial in total knee arthroplasty (TKA). This paper describes the Coronal Plane Alignment of the Knee (CPAK) classification and examines its utility in preoperative soft tissue balance prediction, comparing kinematic alignment (KA) to mechanical alignment (MA). A radiological analysis of 500 healthy and 500 osteoarthritic (OA) knees was used to assess the applicability of the CPAK classification. CPAK comprises nine phenotypes based on the arithmetic HKA (aHKA) that estimates constitutional limb alignment and joint line obliquity (JLO). Intraoperative balance was compared within each phenotype in a cohort of 138 computer-assisted TKAs randomized to KA or MA. Primary outcomes included descriptive analyses of healthy and OA groups per CPAK type, and comparison of balance at 10° of flexion within each type. Secondary outcomes assessed balance at 45° and 90° and bone recuts required to achieve final knee balance within each CPAK type.Aims
Methods
We present the clinical and radiological results at a minimum follow-up of 20 years using a second-generation uncemented total hip arthroplasty (THA). These results are compared to our previously published results using a first-generation hip arthroplasty followed for 20 years. A total of 62 uncemented THAs in 60 patients were performed between 1993 and 1994. The titanium femoral component used in all cases was a Taperloc with a reduced distal stem. The acetabular component was a fully porous coated threaded hemispheric titanium shell (T-Tap ST). The outcome of every femoral and acetabular component with regard to retention or revision was determined for all 62 THAs. Complete clinical follow-up at a minimum of 20 years was obtained on every living patient. Radiological follow-up was obtained on all but one.Aims
Methods
The aim of this study was to determine whether fixation, as opposed to revision arthroplasty, can be safely used to treat reducible Vancouver B type fractures in association with a cemented collarless polished tapered femoral stem (the Exeter). This retrospective cohort study assessed 152 operatively managed consecutive unilateral Vancouver B fractures involving Exeter stems; 130 were managed with open reduction and internal fixation (ORIF) and 22 with revision arthroplasty. Mean follow-up was 6.5 years (SD 2.6; 3.2 to 12.1). The primary outcome measure was revision of at least one component. Kaplan–Meier survival analysis was performed. Regression analysis was used to identify risk factors for revision following ORIF. Secondary outcomes included any reoperation, complications, blood transfusion, length of hospital stay, and mortality.Aims
Methods
Infection after surgery increases treatment costs and is associated with increased mortality. Hip fracture patients have historically had high rates of methicillin-resistant A total of 13,503 patients who presented with a hip fracture over 17 years formed the study population. Multivariable logistic regression was performed to determine risk factors for MRSA and SSI. Autoregressive integrated moving average (ARIMA) modelling adjusted for temporal trends in rates of MRSA. Kaplan-Meier estimators were generated to assess for changes in mortality.Aims
Methods
In the UK, fasciectomy for Dupuytren’s contracture is generally performed under general or regional anaesthetic, with an arm tourniquet and in a hospital setting. We have changed our practice to use local anaesthetic with adrenaline, no arm tourniquet, and perform the surgery in a community setting. We present the outcome of a consecutive series of 30 patients. Prospective data were collected for 30 patients undergoing open fasciectomy on 36 digits (six having two digits affected), over a one-year period and under the care of two surgeons. In total, 10 ml to 20 ml volume of 1% lidocaine with 1:100,000 adrenaline was used. A standard postoperative rehabilitation regime was used. Preoperative health scores, goniometer measurements of metacarpophalangeal (MCP), proximal interphalangeal (PIP) contractures, and Unité Rheumatologique des Affections de la Main (URAM) scores were measured pre- and postoperatively at six and 12 weeks.Aims
Methods
Previous studies have reported an increased risk for postoperative complications in the Medicaid population undergoing total hip arthroplasty (THA). These studies have not controlled for the surgeon’s practice or patient care setting. This study aims to evaluate whether patient point of entry and Medicaid status plays a role in quality outcomes and discharge disposition following THA. The electronic medical record at our institution was retrospectively reviewed for all primary, unilateral THA between January 2016 and January 2018. THA recipients were categorized as either Medicaid or non-Medicaid patients based on a visit to our institution’s Hospital Ambulatory Care Center (HACC) within the six months prior to surgery. Only patients who had been operated on by surgeons (CML, JV, JDS, RS) with at least ten Medicaid and ten non-Medicaid patients were included in the study. The patients included in this study were 56.33% female, had a mean age of 60.85 years, and had a mean BMI of 29.14. The average length of follow-up was 343.73 days.Aims
Methods
Cite this article:
Vitamin E-infused highly crosslinked polyethylene (VEPE) has been introduced into total hip arthroplasty (THA) with the aim of further improving the wear characteristics of moderately and highly crosslinked polyethylenes (ModXLPE and HXLPE). There are few studies analyzing the outcomes of vitamin E-infused components in cemented arthroplasty, though early acetabular component migration has been reported. The aim of this study was to measure five-year polyethylene wear and acetabular component stability of a cemented VEPE acetabular component compared with a ModXLPE cemented acetabular component. In a prospective randomized controlled trial (RCT), we assessed polyethylene wear and acetabular component stability (primary outcome) with radiostereometric analysis (RSA) in 68 patients with reverse hybrid THA at five years follow-up. Patients were randomized to either a VEPE or a ModXLPE cemented acetabular component.Aims
Methods
This study presents patient-reported quality of life (QoL) over the first year following surgical debridement of long bone osteomyelitis. It assesses the bone involvement, antimicrobial options, coverage of soft tissues, and host status (BACH) classification as a prognostic tool and its ability to stratify cases into ‘uncomplicated’ or ‘complex’. Patients with long-bone osteomyelitis were identified prospectively between June 2010 and October 2015. All patients underwent surgical debridement in a single-staged procedure at a specialist bone infection unit. Self-reported QoL was assessed prospectively using the three-level EuroQol five-dimension questionnaire (EQ-5D-3L) index score and visual analogue scale (EQ-VAS) at five postoperative time-points (baseline, 14 days, 42 days, 120 days, and 365 days). BACH classification was applied retrospectively by two clinicians blinded to outcome.Aims
Methods
Tibial plateau fractures are serious injuries about the knee that have the potential to affect patients’ long-term function. To our knowledge, this is the first study to use patient-reported outcomes (PROs) with a musculoskeletal focus to assess the long-term outcome, as compared to a short-term outcome baseline, of tibial plateau fractures treated using modern techniques. In total, 102 patients who sustained a displaced tibial plateau fracture and underwent operative repair by one of three orthopaedic traumatologists at a large, academic medical centre and had a minimum of five-year follow-up were identified. Breakdown of patients by Schatzker classification is as follows: two (1.9%) Schatzker I, 54 (50.9%) Schatzker II, two (1.9%) Schatzker III, 13 (12.3%) Schatzker IV, nine (8.5%) Schatzker V, and 26 (24.5%) Schatzker VI. Follow-up data obtained included: Visual Analogue Scale (VAS) or Numeric Rating Scale (NRS) pain scores, Short Musculoskeletal Functional Assessment (SMFA), and knee range of movement (ROM). Data at latest follow-up were then compared to 12-month data using a paired Aims
Methods
The aim of this study is to determine the effects of the UK lockdown during the COVID-19 pandemic on the orthopaedic admissions, operations, training opportunities, and theatre efficiency in a large district general hospital. The number of patients referred to the orthopaedic team between 1 April 2020 and 30 April 2020 were collected. Other data collected included patient demographics, number of admissions, number and type of operations performed, and seniority of primary surgeon. Theatre time was collected consisting of anaesthetic time, surgical time, time to leave theatre, and turnaround time. Data were compared to the same period in 2019.Aims
Methods
This study aims to determine the proportion of patients with end-stage knee osteoarthritis (OA) possibly suitable for partial (PKA) or combined partial knee arthroplasty (CPKA) according to patterns of full-thickness cartilage loss and anterior cruciate ligament (ACL) status. A cross-sectional analysis of 300 consecutive patients (mean age 69 years (SD 9.5, 44 to 91), mean body mass index (BMI) 30.6 (SD 5.5, 20 to 53), 178 female (59.3%)) undergoing total knee arthroplasty (TKA) for Kellgren-Lawrence grade ≥ 3 knee OA was conducted. The point of maximal tibial bone loss on preoperative lateral radiographs was determined as a percentage of the tibial diameter. At surgery, Lachman’s test and ACL status were recorded. The presence of full-thickness cartilage loss within 16 articular surface regions (two patella, eight femoral, six tibial) was recorded.Aims
Methods
Total knee arthroplasty is an established treatment for knee osteoarthritis with excellent long-term results, but there remains controversy about the role of uncemented prostheses. We present the long-term results of a randomized trial comparing an uncemented tantalum metal tibial component with a conventional cemented component of the same implant design. Patients under the age of 70 years with symptomatic osteoarthritis of the knee were randomized to receive either an uncemented tantalum metal tibial monoblock component or a standard cemented modular component. The mean age at time of recruitment to the study was 63 years (50 to 70), 46 (51.1%) knees were in male patients, and the mean body mass index was 30.4 kg/m2 (21 to 36). The same cruciate retaining total knee system was used in both groups. All patients received an uncemented femoral component and no patients had their patella resurfaced. Patient outcomes were assessed preoperatively and postoperatively using the modified Oxford Knee Score, Knee Society Score, and 12-Item Short-Form Health Survey questionnaire (SF-12) score. Radiographs were analyzed using the American Knee Society Radiograph Evaluation score. Operative complications, reoperations, or revision surgery were recorded. A total of 90 knees were randomized and at last review 77 knees were assessed. In all, 11 patients had died and two were lost to follow-up.Aims
Methods