Advertisement for orthosearch.org.uk
Results 1 - 100 of 443
Results per page:
The Bone & Joint Journal
Vol. 97-B, Issue 12 | Pages 1693 - 1697
1 Dec 2015
Keightley AJ Nawaz SZ Jacob JT Unnithan A Elliott DS Khaleel A

This study aimed to determine the long-term functional, clinical and radiological outcomes in patients with Schatzker IV to VI fractures of the tibial plateau treated with an Ilizarov frame. Clinical, functional and radiological assessment was carried out at a minimum of one year post-operatively. A cohort of 105 patients (62 men, 43 women) with a mean age of 49 years (15 to 87) and a mean follow-up of 7.8 years (1 to 19) were reviewed. There were 18 type IV, 10 type V and 77 type VI fractures. All fractures united with a mean time to union of 20.1 weeks (10.6 to 42.3). No patient developed a deep infection. The median range of movement (ROM) of the knee was 110. o. and the median Iowa score was 85. . Our study demonstrates good long-term functional outcome with no deep infection; spanning the knee had no detrimental effect on the ROM or functional outcome. . High-energy fractures of the tibial plateau may be treated effectively with a fine wire Ilizarov fixator. Cite this article: Bone Joint J 2015;97-B:1693–7


Bone & Joint Open
Vol. 5, Issue 1 | Pages 46 - 52
19 Jan 2024
Assink N ten Duis K de Vries JPM Witjes MJH Kraeima J Doornberg JN IJpma FFA

Aims. Proper preoperative planning benefits fracture reduction, fixation, and stability in tibial plateau fracture surgery. We developed and clinically implemented a novel workflow for 3D surgical planning including patient-specific drilling guides in tibial plateau fracture surgery. Methods. A prospective feasibility study was performed in which consecutive tibial plateau fracture patients were treated with 3D surgical planning, including patient-specific drilling guides applied to standard off-the-shelf plates. A postoperative CT scan was obtained to assess whether the screw directions, screw lengths, and plate position were performed according the preoperative planning. Quality of the fracture reduction was assessed by measuring residual intra-articular incongruence (maximum gap and step-off) and compared to a historical matched control group. Results. A total of 15 patients were treated with 3D surgical planning in which 83 screws were placed by using drilling guides. The median deviation of the achieved screw trajectory from the planned trajectory was 3.4° (interquartile range (IQR) 2.5 to 5.4) and the difference in entry points (i.e. plate position) was 3.0 mm (IQR 2.0 to 5.5) compared to the 3D preoperative planning. The length of 72 screws (86.7%) were according to the planning. Compared to the historical cohort, 3D-guided surgery showed an improved surgical reduction in terms of median gap (3.1 vs 4.7 mm; p = 0.126) and step-off (2.9 vs 4.0 mm; p = 0.026). Conclusion. The use of 3D surgical planning including drilling guides was feasible, and facilitated accurate screw directions, screw lengths, and plate positioning. Moreover, the personalized approach improved fracture reduction as compared to a historical cohort. Cite this article: Bone Jt Open 2024;5(1):46–52


Bone & Joint Research
Vol. 9, Issue 6 | Pages 258 - 267
1 Jun 2020
Yao X Zhou K Lv B Wang L Xie J Fu X Yuan J Zhang Y

Aims. Tibial plateau fractures (TPFs) are complex injuries around the knee caused by high- or low-energy trauma. In the present study, we aimed to define the distribution and frequency of TPF lines using a 3D mapping technique and analyze the rationalization of divisions employed by frequently used classifications. Methods. In total, 759 adult patients with 766 affected knees were retrospectively reviewed. The TPF fragments on CT were multiplanar reconstructed, and virtually reduced to match a 3D model of the proximal tibia. 3D heat mapping was subsequently created by graphically superimposing all fracture lines onto a tibia template. Results. The cohort included 405 (53.4%) cases with left knee injuries, 347 (45.7%) cases with right knee injuries, and seven (0.9%) cases with bilateral injuries. On mapping, the hot zones of the fracture lines were mainly concentrated around the anterior cruciate ligament insertion, posterior cruciate ligament insertion, and the inner part of the lateral condyle that extended to the junctional zone between Gerdy’s tubercle and the tibial tubercle. Moreover, the cold zones were scattered in the posteromedial fragment, superior tibiofibular syndesmosis, Gerdy’s tubercle, and tibial tubercle. TPFs with different Orthopaedic Trauma Association/AO Foundation (OTA/AO) subtypes showed peculiar characteristics. Conclusion. TPFs occurred more frequently in the lateral and intermedial column than in the medial column. Fracture lines of tibial plateau occur frequently in the transition zone with marked changes in cortical thickness. According to 3D mapping, the four-column and nine-segment classification had a high degree of matching as compared to the frequently used classifications. Cite this article: Bone Joint Res 2020;9(6):258–267


The Bone & Joint Journal
Vol. 95-B, Issue 12 | Pages 1697 - 1702
1 Dec 2013
Maroto MD Scolaro JA Henley MB Dunbar RP

Bicondylar tibial plateau fractures result from high-energy injuries. Fractures of the tibial plateau can involve the tibial tubercle, which represents a disruption to the extensor mechanism and logically must be stabilised. The purpose of this study was to identify the incidence of an independent tibial tubercle fracture in bicondylar tibial plateau fractures, and to report management strategies and potential complications. We retrospectively reviewed a prospectively collected orthopaedic trauma database for the period January 2003 to December 2008, and identified 392 bicondylar fractures of the tibial plateau, in which 85 tibial tubercle fractures (21.6%) were identified in 84 patients. There were 60 men and 24 women in our study group, with a mean age of 45.4 years (18 to 71). In 84 fractures open reduction and internal fixation was undertaken, either with screws alone (23 patients) or with a plate and screws (61 patients). The remaining patient was treated non-operatively. In all, 52 fractures were available for clinical and radiological assessment at a mean follow-up of 58.5 weeks (24 to 94). All fractures of the tibial tubercle united, but 24 of 54 fractures (46%) required a secondary procedure for their tibial plateau fracture. Four patients reported pain arising from prominent tubercle plates and screws, which in one patient required removal. Tibial tubercle fractures occurred in over one-fifth of the bicondylar tibial plateau fractures in our series. Fixation is necessary and can be reliably performed with screws alone or with a screw and plate, which restores the extensor mechanism and facilitates early knee flexion. Cite this article: Bone Joint J 2013;95-B:1697–1702


The Bone & Joint Journal
Vol. 101-B, Issue 8 | Pages 1009 - 1014
1 Aug 2019
Ramoutar DN Lefaivre K Broekhuyse H Guy P O’Brien P

Aims. The aim of this study was to determine the trajectory of recovery following fixation of tibial plateau fractures up to five-year follow-up, including simple (Schatzker I-IV) versus complex (Schatzker V-VI) fractures. Patients and Methods. Patients undergoing open reduction and internal fixation (ORIF) for tibial plateau fractures were enrolled into a prospective database. Functional outcome, using the 36-Item Short Form Health Survey Physical Component Summary (SF-36 PCS), was collected at baseline, six months, one year, and five years. The trajectory of recovery for complex fractures (Schatzker V and VI) was compared with simple fractures (Schatzker I to IV). Minimal clinically important difference (MCID) was calculated between timepoints. In all, 182 patients were enrolled: 136 (74.7%) in simple and 46 (25.3%) in complex. There were 103 female patients and 79 male patients with a mean age of 45.8 years (15 to 86). Results. Mean SF-36 PCS improved significantly in both groups from six to 12 months (p < 0.001) and one to five years (simple, p = 0.008; complex, p = 0.007). In both groups, the baseline scores were not reached at five years. The SF-36 PCS was significantly higher in the simple group compared with the complex group at both six months (p = 0.007) and 12 months (p = 0.01), but not at five years (p = 0.17). Between each timepoint, approximately 50% or more of the patients in each group achieved an MCID in their score change, indicating a significant clinical change in condition. The complex group had a much larger drop off in the first six months, with comparable proportions achieving MCID at the subsequent time intervals. Conclusion. Tibial plateau fracture recovery was characterized overall by an initial decline in functional outcome from baseline, followed by a steep improvement from six to 12 months, and ongoing recovery up to five years. In simple patterns, patients tended to achieve a higher functional score by six months compared with the complex patterns. However, comparable functional scores between the groups achieved only at the five-year point suggest later recovery in the complex group. Function does not improve to baseline by five years in either group. This information is useful in counselling patients about the course of prospective recovery. Cite this article: Bone Joint J 2019;101-B:1009–1014


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 109 - 114
1 Jan 2015
Haller JM Holt DC McFadden ML Higgins TF Kubiak EN

The aim of this study was to report the incidence of arthrofibrosis of the knee and identify risk factors for its development following a fracture of the tibial plateau. We carried out a retrospective review of 186 patients (114 male, 72 female) with a fracture of the tibial plateau who underwent open reduction and internal fixation. Their mean age was 46.4 years (19 to 83) and the mean follow-up was16.0 months (6 to 80). A total of 27 patients (14.5%) developed arthrofibrosis requiring a further intervention. Using multivariate regression analysis, the use of a provisional external fixator (odds ratio (OR) 4.63, 95% confidence interval (CI) 1.26 to 17.7, p = 0.021) was significantly associated with the development of arthrofibrosis. Similarly, the use of a continuous passive movement (CPM) machine was associated with significantly less development of arthrofibrosis (OR = 0.32, 95% CI 0.11 to 0.83, p = 0.024). The effect of time in an external fixator was found to be significant, with each extra day of external fixation increasing the odds of requiring manipulation under anaesthesia (MUA) or quadricepsplasty by 10% (OR = 1.10, p = 0.030). High-energy fracture, surgical approach, infection and use of tobacco were not associated with the development of arthrofibrosis. Patients with a successful MUA had significantly less time to MUA (mean 2.9 months; . sd. 1.25) than those with an unsuccessful MUA (mean 4.86 months;. sd. 2.61, p = 0.014). For those with limited movement, therefore, performing an MUA within three months of the injury may result in a better range of movement. . Based our results, CPM following operative fixation for a fracture of the tibial plateau may reduce the risk of the development of arthrofibrosis, particularly in patients who also undergo prolonged provisional external fixation. Cite this article: Bone Joint J 2015;97-B:109–14


The Bone & Joint Journal
Vol. 102-B, Issue 5 | Pages 632 - 637
1 May 2020
Gonzalez LJ Hildebrandt K Carlock K Konda SR Egol KA

Aims. Tibial plateau fractures are serious injuries about the knee that have the potential to affect patients’ long-term function. To our knowledge, this is the first study to use patient-reported outcomes (PROs) with a musculoskeletal focus to assess the long-term outcome, as compared to a short-term outcome baseline, of tibial plateau fractures treated using modern techniques. Methods. In total, 102 patients who sustained a displaced tibial plateau fracture and underwent operative repair by one of three orthopaedic traumatologists at a large, academic medical centre and had a minimum of five-year follow-up were identified. Breakdown of patients by Schatzker classification is as follows: two (1.9%) Schatzker I, 54 (50.9%) Schatzker II, two (1.9%) Schatzker III, 13 (12.3%) Schatzker IV, nine (8.5%) Schatzker V, and 26 (24.5%) Schatzker VI. Follow-up data obtained included: Visual Analogue Scale (VAS) or Numeric Rating Scale (NRS) pain scores, Short Musculoskeletal Functional Assessment (SMFA), and knee range of movement (ROM). Data at latest follow-up were then compared to 12-month data using a paired t-test. Results. Patient-reported functional outcomes as assessed by overall SMFA were statistically significantly improved at five years (p < 0.001) compared with one-year data from the same patients. Patients additionally reported an improvement in the Standardized Mobility Index (p < 0.001), Standardized Emotional Index (p < 0.001), as well as improvement in Standardized Bothersome Index (p = 0.003) between the first year and latest follow-up. Patient-reported pain and knee ROM were similar at five years to their one-year follow-up. In total, 15 of the patients had undergone subsequent orthopaedic surgery for their knees at the time of most recent follow-up. Of note, only one patient had undergone knee arthroplasty following plateau fixation related to post-traumatic osteoarthritis (OA). Conclusion. Knee pain following tibial plateau fracture stabilizes at one year. However, PROs continue to improve beyond one year following tibial plateau fracture, at least in a statistical sense, if not also clinically. Patients displayed statistical improvement across nearly all SMFA index scores at their minimum five-year follow-up compared with their one-year follow-up. Cite this article: Bone Joint J 2020;102-B(5):632–637


Bone & Joint Research
Vol. 8, Issue 8 | Pages 357 - 366
1 Aug 2019
Zhang B Sun H Zhan Y He Q Zhu Y Wang Y Luo C

Objectives. CT-based three-column classification (TCC) has been widely used in the treatment of tibial plateau fractures (TPFs). In its updated version (updated three-column concept, uTCC), a fracture morphology-based injury mechanism was proposed for effective treatment guidance. In this study, the injury mechanism of TPFs is further explained, and its inter- and intraobserver reliability is evaluated to perfect the uTCC. Methods. The radiological images of 90 consecutive TPF patients were collected. A total of 47 men (52.2%) and 43 women (47.8%) with a mean age of 49.8 years (. sd. 12.4; 17 to 77) were enrolled in our study. Among them, 57 fractures were on the left side (63.3%) and 33 were on the right side (36.7%); no bilateral fracture existed. Four observers were chosen to classify or estimate independently these randomized cases according to the Schatzker classification, TCC, and injury mechanism. With two rounds of evaluation, the kappa values were calculated to estimate the inter- and intrareliability. Results. The overall inter- and intraobserver agreements of the injury mechanism were substantial (κ. inter. = 0.699, κ. intra. = 0.749, respectively). The initial position and the force direction, which are two components of the injury mechanism, had substantial agreement for both inter-reliability or intrareliability. The inter- and intraobserver agreements were lower in high-energy fractures (Schatzker types IV to VI; κ. inter. = 0.605, κ. intra. = 0.721) compared with low-energy fractures (Schatzker types I to III; κ. inter. = 0.81, κ. intra. = 0.832). The inter- and intraobserver agreements were relatively higher in one-column fractures (κ. inter. = 0.759, κ. intra. = 0.801) compared with two-column and three-column fractures. Conclusion. The complete theory of injury mechanism of TPFs was first put forward to make the TCC consummate. It demonstrates substantial inter- and intraobserver agreement generally. Furthermore, the injury mechanism can be promoted clinically. Cite this article: B-B. Zhang, H. Sun, Y. Zhan, Q-F. He, Y. Zhu, Y-K. Wang, C-F. Luo. Reliability and repeatability of tibial plateau fracture assessment with an injury mechanism-based concept. Bone Joint Res 2019;8:357–366. DOI: 10.1302/2046-3758.88.BJR-2018-0331.R1


Aims. Our objective was to conduct a systematic review and meta-analysis, to establish whether differences arise in clinical outcomes between autologous and synthetic bone grafts in the operative management of tibial plateau fractures. Methods. A structured search of MEDLINE, EMBASE, the online archives of Bone & Joint Publishing, and CENTRAL databases from inception until 28 July 2021 was performed. Randomized, controlled, clinical trials that compared autologous and synthetic bone grafts in tibial plateau fractures were included. Preclinical studies, clinical studies in paediatric patients, pathological fractures, fracture nonunion, or chondral defects were excluded. Outcome data were assessed using the Risk of Bias 2 (ROB2) framework and synthesized in random-effect meta-analysis. The Preferred Reported Items for Systematic Review and Meta-Analyses guidance was followed throughout. Results. Six studies involving 353 fractures were identified from 3,078 records. Following ROB2 assessment, five studies (representing 338 fractures) were appropriate for meta-analysis. Primary outcomes showed non-significant reductions in articular depression at immediate postoperative (mean difference -0.45 mm, p = 0.25, 95%confidence interval (CI) -1.21 to 0.31, I. 2. = 0%) and long-term (> six months, standard mean difference -0.56, p = 0.09, 95% CI -1.20 to 0.08, I. 2. = 73%) follow-up in synthetic bone grafts. Secondary outcomes included mechanical alignment, limb functionality, and defect site pain at long-term follow-up, perioperative blood loss, duration of surgery, occurrence of surgical site infections, and secondary surgery. Mean blood loss was lower (90.08 ml, p < 0.001, 95% CI 41.49 to 138.67) and surgery was shorter (16.17 minutes, p = 0.04, 95% CI 0.39 to 31.94) in synthetic treatment groups. All other secondary measures were statistically comparable. Conclusion. All studies reported similar methodologies and patient populations; however, imprecision may have arisen through performance variation. These findings supersede previous literature and indicate that, despite perceived biological advantages, autologous bone grafting does not demonstrate superiority to synthetic grafts. When selecting a void filler, surgeons should consider patient comorbidity, environmental and societal factors in provision, and perioperative and postoperative care provision. Cite this article: Bone Jt Open 2022;3(3):218–228


Bone & Joint Open
Vol. 4, Issue 4 | Pages 273 - 282
20 Apr 2023
Gupta S Yapp LZ Sadczuk D MacDonald DJ Clement ND White TO Keating JF Scott CEH

Aims. To investigate health-related quality of life (HRQoL) of older adults (aged ≥ 60 years) after tibial plateau fracture (TPF) compared to preinjury and population matched values, and what aspects of treatment were most important to patients. Methods. We undertook a retrospective, case-control study of 67 patients at mean 3.5 years (SD 1.3; 1.3 to 6.1) after TPF (47 patients underwent fixation, and 20 nonoperative management). Patients completed EuroQol five-dimension three-level (EQ-5D-3L) questionnaire, Lower Limb Function Scale (LEFS), and Oxford Knee Scores (OKS) for current and recalled prefracture status. Propensity score matching for age, sex, and deprivation in a 1:5 ratio was performed using patient level data from the Health Survey for England to obtain a control group for HRQoL comparison. The primary outcome was the difference in actual (TPF cohort) and expected (matched control) EQ-5D-3L score after TPF. Results. TPF patients had a significantly worse EQ-5D-3L utility (mean difference (MD) 0.09, 95% confidence interval (CI) 0.00 to 0.16; p < 0.001) following their injury compared to matched controls, and had a significant deterioration (MD 0.140, 95% CI 0 to 0.309; p < 0.001) relative to their preoperative status. TPF patients had significantly greater pre-fracture EQ-5D-3L scores compared to controls (p = 0.003), specifically in mobility and pain/discomfort domains. A decline in EQ-5D-3L greater than the minimal important change of 0.105 was present in 36/67 TPF patients (53.7%). Following TPF, OKS (MD -7; interquartile range (IQR) -1 to -15) and LEFS (MD -10; IQR -2 to -26) declined significantly (p < 0.001) from pre-fracture levels. Of the 12 elements of fracture care assessed, the most important to patients were getting back to their own home, having a stable knee, and returning to normal function. Conclusion. TPFs in older adults were associated with a clinically significant deterioration in HRQoL compared to preinjury level and age, sex, and deprivation matched controls for both undisplaced fractures managed nonoperatively and displaced or unstable fractures managed with internal fixation. Cite this article: Bone Jt Open 2023;4(4):273–282


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 861 - 867
1 Jul 2020
Hiranaka T Yoshikawa R Yoshida K Michishita K Nishimura T Nitta S Takashiba K Murray D

Aims. Cementless unicompartmental knee arthroplasty (UKA) has advantages over cemented UKA, including improved fixation, but has a higher risk of tibial plateau fracture, particularly in Japanese patients. The aim of this multicentre study was to determine when cementless tibial components could safely be used in Japanese patients based on the size and shape of the tibia. Methods. The study involved 212 cementless Oxford UKAs which were undertaken in 174 patients in six hospitals. The medial eminence line (MEL), which is a line parallel to the tibial axis passing through the tip of medial intercondylar eminence, was drawn on preoperative radiographs. Knees were classified as having a very overhanging medial tibial condyle if this line passed medial to the medial tibial cortex. They were also classified as very small if a size A/AA tibial component was used. Results. The overall rate of fracture was 8% (17 out of 212 knees). The rate was higher in knees with very overhanging condyles (Odds ratio (OR) 13; p < 0.001) and with very small components (OR 7; p < 0.001). The OR was 21 (p < 0.001) in those with both very overhanging condyles and very small components. In all, 69% of knees (147) had neither very overhanging nor very small components, and the fracture rate in these patients was 1.4% (2 out of 147 knees). Males had a significantly reduced risk of fracture (OR 0.13; p = 0.002), probably because no males required very small components and females were more likely to have very overhanging condyles (OR 3; p = 0.013). 31% of knees (66) were in males and in these the rate of fracture was 1.5% (1 out of 66 knees). Conclusion. The rate of tibial plateau fracture in Japanese patients undergoing cementless UKA is high. We recommend that cemented tibial fixation should be used in Japanese patients who require very small components or have very overhanging condyles, as identified from preoperative radiographs. In the remaining 69% of knees cementless fixation can be used. This approach should result in a low rate of fracture. Cite this article: Bone Joint J 2020;102-B(7):861–867


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 9 | Pages 1233 - 1236
1 Sep 2005
Gaston P Will EM Keating JF

We assessed the functional outcome following fracture of the tibial plateau in 63 consecutive patients. Fifty-one patients were treated by internal fixation, five by combined internal and external fixation and seven non-operatively. Measurements of joint movement and muscle function were made using a muscle dynamometer at three, six and 12 months following injury. Thirteen patients (21%) had a residual flexion contracture at one year. Only nine (14%) patients achieved normal quadriceps muscle strength at 12 months, while 19 (30%) achieved normal hamstring muscle strength. Recovery was significantly slower in patients older than 40 years of age. We conclude that there is significant impairment of movement and muscle function after fracture of the tibial plateau and that the majority of patients have not fully recovered one year after injury


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 7 | Pages 983 - 988
1 Sep 2003
Satku K Kumar VP Chong SM Thambyah A

The natural history of spontaneous osteonecrosis of the medial tibial plateau remains controversial and incomplete. We have studied 21 patients (aged between 53 and 77 years) with clinical and scintigraphic features of spontaneous osteonecrosis of the medial tibial plateau who were observed prospectively for at least three years (37 months to 8.5 years). The mean duration of follow-up was 5.6 years. The mean duration of symptoms at presentation was 4.7 weeks (3 days to 12 weeks). Radiographs of the affected knee at the first visit were normal in 15 patients and mildly arthritic in six. The characteristic radiographic lesion of osteonecrosis was noted at presentation in five of the mildly arthritic knees and during the evolution of the disease in eight of the radiographically normal knees. During the follow-up, subchondral sclerosis of the affected medial tibial plateau was noted in 16 knees. There are three distinct patterns of outcome: 1) acute extensive collapse of the medial tibial plateau in two knees within three months of onset; 2) rapid progression to varying degrees of osteoarthritis in 12 knees, in eight within a year, in all within two years and deterioration of the pre-existing osteoarthritis in three; and 3) complete resolution in four knees, two of which were normal at presentation and two mildly osteoarthritic. The two patients with acute extensive collapse and three who had rapid progression to severe osteoarthritis required total knee arthroplasty. We conclude that osteonecrosis of the medial tibial plateau progresses in most cases to significant degenerative disease of the knee


Bone & Joint Research
Vol. 10, Issue 7 | Pages 380 - 387
5 Jul 2021
Shen J Sun D Fu J Wang S Wang X Xie Z

Aims. In contrast to operations performed for other fractures, there is a high incidence rate of surgical site infection (SSI) post-open reduction and internal fixation (ORIF) done for tibial plateau fractures (TPFs). This study investigates the effect of induced membrane technique combined with internal fixation for managing SSI in TPF patients who underwent ORIF. Methods. From April 2013 to May 2017, 46 consecutive patients with SSI post-ORIF for TPFs were managed in our centre with an induced membrane technique. Of these, 35 patients were included for this study, with data analyzed in a retrospective manner. Results. All participants were monitored for a mean of 36 months (24 to 62). None were subjected to amputations. A total of 21 patients underwent two-stage surgeries (Group A), with 14 patients who did not receive second-stage surgery (Group B). Group A did not experience infection recurrence, and no implant or cement spacer loosening was noted in Group B for at least 24 months of follow-up. No significant difference was noted in the Lower Extremity Functional Scale (LEFS) and the Hospital for Special Surgery Knee Score (HSS) between the two groups. The clinical healing time was significantly shorter in Group B (p<0.001). Those with longer duration of infection had poorer functional status (p<0.001). Conclusion. Management of SSI post-ORIF for TPF with induced membrane technique combined with internal fixation represents a feasible mode of treatment with satisfactory outcomes in terms of infection control and functional recovery. Cite this article: Bone Joint Res 2021;10(7):380–387


The Journal of Bone & Joint Surgery British Volume
Vol. 63-B, Issue 4 | Pages 575 - 578
1 Nov 1981
Scotland T Wardlaw D

A series of 29 patients with fractures of the tibial plateau were treated by means of a cast-brace. There were seven wedge fractures of the lateral tibial condyle, two dicondylar fractures and 20 compression fractures involving the lateral tibial plateau. The seven patients with wedge fractures were treated by skin or skeletal traction, followed as soon as possible by flexion exercises for the knee. Cast-braces were applied to all fractures as soon as possible after injury, and the patients allowed to bear weight freely. Early restoration of function of the injured limb was thereby achieved. The results of our study over a period of two and a half years indicate that cast-bracing is a very satisfactory method of treating fractures of the tibial plateau. All the fractures united, the movements and control of the knee were excellent, and valgus or varus deformity was unchanged before application and after removal of the brace


The Bone & Joint Journal
Vol. 106-B, Issue 1 | Pages 28 - 37
1 Jan 2024
Gupta S Sadczuk D Riddoch FI Oliver WM Davidson E White TO Keating JF Scott CEH

Aims. This study aims to determine the rate of and risk factors for total knee arthroplasty (TKA) after operative management of tibial plateau fractures (TPFs) in older adults. Methods. This is a retrospective cohort study of 182 displaced TPFs in 180 patients aged ≥ 60 years, over a 12-year period with a minimum follow-up of one year. The mean age was 70.7 years (SD 7.7; 60 to 89), and 139/180 patients (77.2%) were female. Radiological assessment consisted of fracture classification; pre-existing knee osteoarthritis (OA); reduction quality; loss of reduction; and post-traumatic OA. Fracture depression was measured on CT, and the volume of defect estimated as half an oblate spheroid. Operative management, complications, reoperations, and mortality were recorded. Results. Nearly half of the fractures were Schatzker II AO B3.1 fractures (n = 85; 47%). Radiological knee OA was present at fracture in 59/182 TPFs (32.6%). Primary management was fixation in 174 (95.6%) and acute TKA in eight (4.4%). A total of 13 patients underwent late TKA (7.5%), most often within two years. By five years, 21/182 12% (95% confidence interval (CI) 6.0 to 16.7) had required TKA. Larger volume defects of greater depth on CT (median 15.9 mm vs 9.4 mm; p < 0.001) were significantly associated with TKA requirement. CT-measured joint depression of > 12.8 mm was associated with TKA requirement (area under the curve (AUC) 0.766; p = 0.001). Severe joint depression of > 15.5 mm (hazard ratio (HR) 6.15 (95% CI 2.60 to 14.55); p < 0.001) and pre-existing knee OA (HR 2.70 (95% CI 1.14 to 6.37); p = 0.024) were independently associated with TKA requirement. Where patients with severe joint depression of > 15.5 mm were managed with fixation, 11/25 ultimately required TKA. Conclusion. Overall, 12% of patients aged ≥ 60 years underwent TKA within five years of TPF. Severe joint depression and pre-existing knee arthritis were independent risk factors for both post-traumatic OA and TKA. These features should be investigated as potential indications for acute TKA in older adults with TPFs. Cite this article: Bone Joint J 2024;106-B(1):28–37


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 4 | Pages 426 - 433
1 Apr 2009
Musahl V Tarkin I Kobbe P Tzioupis C Siska PA Pape H

The operative treatment of displaced fractures of the tibial plateau is challenging. Recent developments in the techniques of internal fixation, including the development of locked plating and minimal invasive techniques have changed the treatment of these fractures. We review current surgical approaches and techniques, improved devices for internal fixation and the clinical outcome after utilisation of new methods for locked plating


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 9 | Pages 1227 - 1232
1 Sep 2005
Brouwer RW Bierma-Zeinstra SMA van Koeveringe AJ Verhaar JAN

Our aim was to compare the degree of patellar descent and alteration in angle of the inclination of the tibial plateau in lateral closing-wedge and medial opening-wedge high tibial osteotomy (HTO) in 51 consecutive patients with osteoarthritis of the medial compartment and varus malalignment. Patellar height was measured by the Insall-Salvati (IS) and the Blackburne-Peel (BP) ratios. The tibial inclination was determined by the Moore-Harvey (MH) method. Multivariate linear regression analysis was used to determine the influence of the type of HTO (closing vs opening wedge) on the post-operative patellar height or tibial inclination. The intra- and interobserver variability of these methods was determined before operation and at follow-up at one year. After an opening-wedge HTO the patellar height was significantly more decreased (mean post-operative difference: IS = 0.15; 95% confidence interval (CI) 0.06 to 0.23; BP = 0.11; 95% CI 0.05 to 0.18) compared with a closing-wedge HTO. The angle of tibial inclination differed significantly (mean post-operative difference MH = −6.40°; 95% CI −8.74 to −4.02) between the two HTO techniques, increasing after opening-wedge HTO and decreasing after closing-wedge HTO. There was no clinically-relevant difference in the intra- and interobserver variability of measurements of patellar height either before or after HTO


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 1 | Pages 68 - 73
1 Jan 2003
Keating JF Hajducka CL Harper J

We used calcium-phosphate cement combined with minimal internal fixation to treat 49 fractures of the lateral tibial plateau. There were 25 split depression fractures, 22 pure depression fractures and two bicondylar fractures. Anatomical reduction was obtained in 38 fractures, satisfactory reduction in nine and imperfect reduction in two. Of 44 patients reviewed at one year, 33 were rated as having an excellent reduction. Functional outcome as measured by the Rasmussen score was good or excellent at six months in 92% (44/48) of patients and in 95% (42/44) at one year. Eight (16%) showed some loss of reduction of the plateau. In seven of these the loss of reduction was slight (< 3 mm) and no action was taken. One patient with a deep infection had gross loss of reduction and a poor functional outcome. Calcium-phosphate cement is a useful alternative to bone grafting for the treatment of fractures of the tibial plateau


Bone & Joint Research
Vol. 5, Issue 4 | Pages 122 - 129
1 Apr 2016
Small SR Rogge RD Malinzak RA Reyes EM Cook PL Farley KA Ritter MA

Objectives. Initial stability of tibial trays is crucial for long-term success of total knee arthroplasty (TKA) in both primary and revision settings. Rotating platform (RP) designs reduce torque transfer at the tibiofemoral interface. We asked if this reduced torque transfer in RP designs resulted in subsequently reduced micromotion at the cemented fixation interface between the prosthesis component and the adjacent bone. Methods. Composite tibias were implanted with fixed and RP primary and revision tibial trays and biomechanically tested under up to 2.5 kN of axial compression and 10° of external femoral component rotation. Relative micromotion between the implanted tibial tray and the neighbouring bone was quantified using high-precision digital image correlation techniques. Results. Rotational malalignment between femoral and tibial components generated 40% less overall tibial tray micromotion in RP designs than in standard fixed bearing tibial trays. RP trays reduced micromotion by up to 172 µm in axial compression and 84 µm in rotational malalignment models. Conclusions. Reduced torque transfer at the tibiofemoral interface in RP tibial trays reduces relative component micromotion and may aid long-term stability in cases of revision TKA or poor bone quality. Cite this article: Mr S. R. Small. Micromotion at the tibial plateau in primary and revision total knee arthroplasty: fixed versus rotating platform designs. Bone Joint Res 2016;5:122–129. DOI: 10.1302/2046-3758.54.2000481


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 5 | Pages 691 - 699
1 Jul 2003
Ali AM Burton M Hashmi M Saleh M

Fine-wire accepted as a minimally external fixation is invasive technique, which can provide better outcomes than traditional open methods in the management of complex fractures of the tibial plateau. Available fixators vary in their biomechanical stability, and we believe that a stable beam-loading system is essential for consistently good outcomes. We assessed, prospectively, the clinical, radiological and general health status of 20 of 21 consecutive patients with complex fractures of the tibial plateau who had been treated using a standard protocol, with percutaneous screw fixation and a neutralisation concept with a fine wire beam-loading fixator allowing early weight-bearing. Bony union was achieved in all patients, with 85% having good or excellent results. Full weight-bearing started during the first six weeks in 60% of patients. The general health status assessment correlated well with the knee scores and reflected a satisfactory outcome


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 3 | Pages 488 - 490
1 May 1994
Vangsness C Ghaderi B Hohl M Moore T

We examined 36 consecutive patients with closed tibial plateau fractures under anaesthesia and by diagnostic and operative arthroscopy before treating them by closed or open reduction and internal fixation. Following the principle of Hohl (1967) (Fig. 1) there were 9 minimally displaced fractures (type I), 6 with local depression (type II), 13 with split depression (type III), 7 with total condylar depression (type IV), and one bicondylar comminuted upper tibial fracture (type V). Seventeen (47%) of knees were found to have associated meniscal injuries which required surgical treatment; five repairs and 12 partial meniscectomies. Neither the type of plateau fracture nor the presence or absence of ligament injury correlated with meniscal tear. There were no intraoperative or postoperative complications from arthroscopy


The Journal of Bone & Joint Surgery British Volume
Vol. 54-B, Issue 2 | Pages 256 - 262
1 May 1972
Kay NRM Martins HD

1. Thirty-nine patients with rheumatoid arthritis who had had a MacIntosh tibial plateau hemiarthroplasty are reviewed. 2. From the clinical findings it is possible to suggest a basis for the selection of suitable patients for the procedure. 3. Eighty-five per cent of the patients obtained relief of pain with good function of the knee. 4. The complications were infection and instability of the prosthesis


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 1 | Pages 84 - 88
1 Jan 1987
Dias J Stirling A Finlay D Gregg P

Sixteen consecutive patients with tibial plateau fractures were investigated by standard radiography, biplanar tomography and computerised axial tomograms (CT scans). It was found that CT scanning proved most helpful for classifying the type of fracture, for evaluating the degree of comminution, and for measuring displacement. Moreover, because a single position was maintained throughout the investigation, the patients felt less discomfort than during other assessment procedures. For these reasons CT scanning is recommended for evaluating this type of fracture


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 1 | Pages 49 - 52
1 Jan 1990
Jensen D Rude C Duus B Bjerg-Nielsen A

We evaluated the long-term results of 109 tibial plateau fractures, 61 treated by skeletal traction and early knee movement and 48 treated by surgery, at an average follow-up of 70 months. The functional results were much the same, though meniscectomy had been performed in almost half of the surgical patients. Time in bed and duration of hospital stay were clearly shorter after surgery (p less than 0.0001). We concluded that conservative management is a valid alternative to surgery, but should probably be reserved for cases where operation is undesirable. Future studies should compare surgery without meniscectomy and conservative treatment using cast braces to reduce the time in traction


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 817 - 823
1 Jun 2011
Solomon LB Callary SA Stevenson AW McGee MA Chehade MJ Howie DW

We investigated the stability of seven Schatzker type II fractures of the lateral tibial plateau treated by subchondral screws and a buttress plate followed by immediate partial weight-bearing. In order to assess the stability of the fracture, weight-bearing inducible displacements of the fracture fragments and their migration over a one-year period were measured by differentially loaded radiostereometric analysis and standard radiostereometric analysis, respectively. The mean inducible craniocaudal fracture fragment displacements measured −0.30 mm (−0.73 to 0.02) at two weeks and 0.00 mm (−0.12 to 0.15) at 52 weeks. All inducible displacements were elastic in nature under all loads at each examination during follow-up. At one year, the mean craniocaudal migration of the fracture fragments was −0.34 mm (−1.64 to 1.51). Using radiostereometric methods, this case series has shown that in the Schatzker type II fractures investigated, internal fixation with subchondral screws and a buttress plate provided adequate stability to allow immediate post-operative partial weight-bearing, without harmful consequences


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 3 | Pages 478 - 480
1 May 1999
Parker PJ Tepper KB Brumback RJ Novak VP Belkoff SM

Type-I fractures of the lateral tibial plateau were simulated by osteotomy in 18 pairs of unembalmed cadaver tibiae. One fracture of each pair was fixed with two lag screws whereas the contralateral site was stabilised with three lag screws, or two lag screws plus an antiglide screw. The lateral plateau was displaced downwards using a servohydraulic materials testing machine and the resulting force and articular surface gap were recorded. Yield load was defined as the maximum load needed to create a 2.0 mm articular offset at the fracture line. The yield loads of the three-lag-screw (307 ± 240 N) and antiglide constructs (342 ± 249 N) were not significantly different from their two-screw control constructs (231 ± 227 and 289 ± 245 N, respectively). We concluded that adding an antiglide screw or a third lag screw did not provide any biomechanical advantage in stabilising these fractures


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 2 | Pages 285 - 289
1 Mar 1994
Georgiadis G

We report the use of combined anterior and posterior approaches for the reduction and fixation of complex tibial plateau fractures involving a large split posteromedial fragment. In four patients, we used a posterior plate to fix the posteromedial fragment. All fractures united in good position with no significant complications, and all patients had a good range of knee movement. This technique should be considered for complex fractures in which there is a substantial posteromedial fragment (split) component


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 5 | Pages 710 - 717
1 Sep 1996
Dendrinos GK Kontos S Katsenis D Dalas A

We treated 24 patients with high-energy fractures of the tibial plateau by the Ilizarov fixator and transfixion wires. Eleven fractures were open, and 20 patients had complex injuries. Twelve were treated by ligamentotaxis and percutaneous fixation, seven by limited open reduction and five by extensive open reduction. All were followed for at least 24 months. All the fractures united, with an average time to healing of 14.4 weeks. Thirteen patients achieved full extension and 13 more than 110° of flexion. Twenty-two knees were stable. Fifteen patients walked normally and the rest with only a slight limp. All but two knees had an articular step-off of less than 4 mm and all had normal axial alignment except two. There were no cases of postoperative skin infection, osteomyelitis or septic arthritis. Ilizarov circular fixation is an ideal method of treatment for these fractures when extensive dissection and internal fixation are contraindicated due to trauma to the soft tissue, deficiency of bone stock, and bony comminution


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 6 | Pages 959 - 964
1 Nov 1998
Scheerlinck T Ng CS Handelberg F Casteleyn PP

We carried out percutaneous, arthroscopically- and fluoroscopically-assisted osteosynthesis of fractures of the tibial plateau in 52 patients, of whom 38 were assessed using the HSS knee score and standing radiographs. We reviewed 31 AO type-B fractures and seven type-C fractures after a mean follow-up of five years (1 to 14). Fixation was achieved using percutaneous screws and/or an external frame; 33 associated intra-articular injuries, diagnosed in 21 out of the 38 patients, were treated arthroscopically. Subjectively, 94.7% of the patients reviewed were satisfied. According to the HSS knee score 78.9% of the results were excellent, 13.2% good, 7.9% fair and none was poor. Narrowing of the joint space was found in 28.9% of the injured and 5.3% of the unaffected knees and axial deviation of 5° to 10° in 15.8% of the injured and 10.5% of the unaffected knees. Of the 52 fractures, reduction was incomplete in one, and in two secondary displacement occurred, of which one required corrective osteotomy. Deep-venous thrombosis occurred in four cases. The technique has proved to be safe but demanding. It facilitates diagnosis and appropriate treatment of associated intra-articular lesions


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 2 | Pages 290 - 292
1 Mar 1994
Vanek J

We report a case of an apparent avulsion fracture of the posteromedial margin of the medial plateau of the tibia. This was associated with a tear of the medial meniscus and rupture of the anterior cruciate ligament (ACL). This triad has been previously reported, and the plateau fracture was related to the insertion of the semimembranosus tendon. The detailed investigation of our case and some experiments on cadaver knees showed that the injury was not an avulsion fracture but was produced by varus and external rotation forces on a flexed knee. It was due to the anterior subluxation of the medial tibial plateau after rupture of the ACL


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 3 | Pages 330 - 333
1 Mar 2008
Lankester BJA Cottam HL Pinskerova V Eldridge JDJ Freeman MAR

From a search of MRI reports on knees, 20 patients were identified with evidence of early anteromedial osteoarthritis without any erosion of bone and a control group of patients had an acute rupture of the anterior cruciate ligament. The angle formed between the extension and flexion facets of the tibia, which is known as the extension facet angle, was measured on a sagittal image at the middle of the medial femoral condyle.

The mean extension facet angle in the control group was 14° (3° to 25°) and was unrelated to age (Spearman’s rank coefficient, p = 0.30, r = 0.13). The mean extension facet angle in individuals with MRI evidence of early anteromedial osteoarthritis was 19° (13° to 26°, SD 4°). This difference was significant (Mann-Whitney U test, p < 0.001).

A wide variation in the extension facet angle was found in the normal control knees and an association between an increased extension facet angle and MRI evidence of early anteromedial osteoarthritis. Although a causal link has not been demonstrated, we postulate that a steeper extension facet angle might increase the duration of loading on the extension facet during the stance phase of gait, and that this might initiate failure of the articular cartilage.


The Journal of Bone & Joint Surgery British Volume
Vol. 64-B, Issue 3 | Pages 336 - 339
1 Jun 1982
Struben P

The suggestion that the knee behaves like a closed kinematic chain has been tested experimentally. The tibial joint surfaces were replaced by a deformable material and new surfaces were moulded by flexion and extension of the knee. The results support the closed kinematic chain theory; the newly moulded joint surfaces strikingly resemble the original joint surfaces. Inferences are drawn to explain why a fracture of the tibial condyle will remould with early mobilisation of the knee; why a jerk is elicited in tests for anterolateral instability; and why a flexion-compression force alone is unlikely to damage the menisci.


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 6 | Pages 1005 - 1005
1 Nov 1991
Thomas M Schofield C Unwin A


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 3 | Pages 463 - 463
1 Apr 2000
TAN JW


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 1 | Pages 152 - 153
1 Jan 2000
EARNSHAW S


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 7 | Pages 1088 - 1088
1 Sep 2003
LERNER A HORESH Z


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 2 | Pages 320 - 320
1 Mar 1989
Sharif D Braddock G


Bone & Joint Research
Vol. 11, Issue 6 | Pages 362 - 370
9 Jun 2022
Zhou J He Z Cui J Liao X Cao H Shibata Y Miyazaki T Zhang J

Aims. Osteoarthritis (OA) is a common degenerative joint disease. The osteocyte transcriptome is highly relevant to osteocyte biology. This study aimed to explore the osteocyte transcriptome in subchondral bone affected by OA. Methods. Gene expression profiles of OA subchondral bone were used to identify disease-relevant genes and signalling pathways. RNA-sequencing data of a bone loading model were used to identify the loading-responsive gene set. Weighted gene co-expression network analysis (WGCNA) was employed to develop the osteocyte mechanics-responsive gene signature. Results. A group of 77 persistent genes that are highly relevant to extracellular matrix (ECM) biology and bone remodelling signalling were identified in OA subchondral lesions. A loading responsive gene set, including 446 principal genes, was highly enriched in OA medial tibial plateaus compared to lateral tibial plateaus. Of this gene set, a total of 223 genes were identified as the main contributors that were strongly associated with osteocyte functions and signalling pathways, such as ECM modelling, axon guidance, Hippo, Wnt, and transforming growth factor beta (TGF-β) signalling pathways. We limited the loading-responsive genes obtained via the osteocyte transcriptome signature to identify a subgroup of genes that are highly relevant to osteocytes, as the mechanics-responsive osteocyte signature in OA. Based on WGCNA, we found that this signature was highly co-expressed and identified three clusters, including early, late, and persistently responsive genes. Conclusion. In this study, we identified the mechanics-responsive osteocyte signature in OA-lesioned subchondral bone. Cite this article: Bone Joint Res 2022;11(6):362–370


The Bone & Joint Journal
Vol. 104-B, Issue 10 | Pages 1118 - 1125
4 Oct 2022
Suda Y Hiranaka T Kamenaga T Koide M Fujishiro T Okamoto K Matsumoto T

Aims. A fracture of the medial tibial plateau is a serious complication of Oxford mobile-bearing unicompartmental knee arthroplasty (OUKA). The risk of these fractures is reportedly lower when using components with a longer keel-cortex distance (KCDs). The aim of this study was to examine how slight varus placement of the tibial component might affect the KCDs, and the rate of tibial plateau fracture, in a clinical setting. Methods. This retrospective study included 255 patients who underwent 305 OUKAs with cementless tibial components. There were 52 males and 203 females. Their mean age was 73.1 years (47 to 91), and the mean follow-up was 1.9 years (1.0 to 2.0). In 217 knees in 187 patients in the conventional group, tibial cuts were made orthogonally to the tibial axis. The varus group included 88 knees in 68 patients, and tibial cuts were made slightly varus using a new osteotomy guide. Anterior and posterior KCDs and the origins of fracture lines were assessed using 3D CT scans one week postoperatively. The KCDs and rate of fracture were compared between the two groups. Results. Medial tibial fractures occurred after surgery in 15 patients (15 OUKAs) in the conventional group, but only one patient (one OUKA) had a tibial fracture after surgery in the varus group. This difference was significant (6.9% vs 1.1%; p = 0.029). The mean posterior KCD was significantly shorter in the conventional group (5.0 mm (SD 1.7)) than in the varus group (6.1 mm (SD 2.1); p = 0.002). Conclusion. In OUKA, the distance between the keel and posterior tibial cortex was longer in our patients with slight varus alignment of the tibial component, which seems to decrease the risk of postoperative tibial fracture. Cite this article: Bone Joint J 2022;104-B(10):1118–1125


Bone & Joint Research
Vol. 8, Issue 12 | Pages 593 - 600
1 Dec 2019
Koh Y Lee J Lee H Kim H Chung H Kang K

Aims. Commonly performed unicompartmental knee arthroplasty (UKA) is not designed for the lateral compartment. Additionally, the anatomical medial and lateral tibial plateaus have asymmetrical geometries, with a slightly dished medial plateau and a convex lateral plateau. Therefore, this study aims to investigate the native knee kinematics with respect to the tibial insert design corresponding to the lateral femoral component. Methods. Subject-specific finite element models were developed with tibiofemoral (TF) and patellofemoral joints for one female and four male subjects. Three different TF conformity designs were applied. Flat, convex, and conforming tibial insert designs were applied to the identical femoral component. A deep knee bend was considered as the loading condition, and the kinematic preservation in the native knee was investigated. Results. The convex design, the femoral rollback, and internal rotation were similar to those of the native knee. However, the conforming design showed a significantly decreased femoral rollback and internal rotation compared with that of the native knee (p < 0.05). The flat design showed a significant difference in the femoral rollback; however, there was no difference in the tibial internal rotation compared with that of the native knee. Conclusion. The geometry of the surface of the lateral tibial plateau determined the ability to restore the rotational kinematics of the native knee. Surgeons and implant designers should consider the geometry of the anatomical lateral tibial plateau as an important factor in the restoration of native knee kinematics after lateral UKA. Cite this article: Bone Joint Res 2019;8:593–600


Bone & Joint 360
Vol. 12, Issue 2 | Pages 34 - 36
1 Apr 2023

The April 2023 Trauma Roundup. 360. looks at: Displaced femoral neck fractures in patients aged 55 to 70 years: internal fixation or total hip arthroplasty?; Tibial plateau fractures: continuous passive motion approves range of motion; Lisfranc fractures: to fuse or not to fuse, that is the question; Is hardware removal after clavicle fracture plate fixation beneficial?; Fixation to coverage in Grade IIIB open fractures – what’s the time window?; Nonoperative versus locking plate fixation in the proximal humerus; Retrograde knee nailing or lateral plate for distal femur fractures?


Bone & Joint 360
Vol. 13, Issue 2 | Pages 20 - 23
1 Apr 2024

The April 2024 Knee Roundup. 360. looks at: Challenging the status quo: re-evaluating the impact of obesity on unicompartmental knee arthroplasty outcomes; Timing matters: the link between ACL reconstruction delays and cartilage damage; Custom fit or off the shelf: evaluating patient outcomes in tailored versus standard knee replacements; Revolutionizing knee replacement: a comparative study on robotic-assisted and computer-navigated techniques; Pre-existing knee osteoarthritis and severe joint depression are associated with the need for total knee arthroplasty after tibial plateau fracture in patients aged over 60 years; Modern digital therapies?; A matched study on fracture rates following knee replacement surgeries;


Aims. Mobile-bearing unicompartmental knee arthroplasty (UKA) with a flat tibial plateau has not performed well in the lateral compartment, leading to a high rate of dislocation. For this reason, the Domed Lateral UKA with a biconcave bearing was developed. However, medial and lateral tibial plateaus have asymmetric anatomical geometries, with a slightly dished medial and a convex lateral plateau. Therefore, the aim of this study was to evaluate the extent at which the normal knee kinematics were restored with different tibial insert designs using computational simulation. Methods. We developed three different tibial inserts having flat, conforming, and anatomy-mimetic superior surfaces, whereas the inferior surface in all was designed to be concave to prevent dislocation. Kinematics from four male subjects and one female subject were compared under deep knee bend activity. Results. The conforming design showed significantly different kinematics in femoral rollback and internal rotation compared to that of the intact knee. The flat design showed significantly different kinematics in femoral rotation during high flexion. The anatomy-mimetic design preserved normal knee kinematics in femoral rollback and internal rotation. Conclusion. The anatomy-mimetic design in lateral mobile UKA demonstrated restoration of normal knee kinematics. Such design may allow achievement of the long sought normal knee characteristics post-lateral mobile UKA. However, further in vivo and clinical studies are required to determine whether this design can truly achieve a more normal feeling of the knee and improved patient satisfaction. Cite this article: Bone Joint Res 2020;9(7):421–428


Objectives. Activation of the leptin pathway is closely correlated with human knee cartilage degeneration. However, the role of the long form of the leptin receptor (Ob-Rb) in cartilage degeneration needs further study. The aim of this study was to determine the effect of increasing the expression of Ob-Rb on chondrocytes using a lentiviral vector containing Ob-Rb. Methods. The medial and lateral cartilage samples of the tibial plateau from 12 osteoarthritis (OA) patients were collected. Ob-Rb messenger RNA (mRNA) was detected in these samples. The Ob-Rb-overexpressing chondrocytes and controls were treated with different doses of leptin for two days. The activation of the p53/p21 pathway and the number of senescence-associated β-galactosidase (SA-β-gal)-positive cells were evaluated. The mammalian target of rapamycin (mTOR) signalling pathway and autophagy were detected after the chondrocytes were treated with a high dose of leptin. Results. In total, 12 cases were found to have severe medial cartilage wear compared with the lateral cartilage. Immunofluorescence showed that the expression of Ob-Rb in the medial cartilage of the tibial plateau was high. High levels of leptin led to cell cycle arrest and inhibited autophagy. After overexpression of Ob-Rb, the physiological dose of leptin induced cell senescence in the chondrocytes. High doses of leptin inhibited autophagy by activating the mTOR signalling pathway. Blockade of the mTOR signalling pathway could restore autophagy and partially reverse senescence induced by leptin in chondrocytes. Conclusion. In summary, the present study demonstrated that high doses of leptin induce cell senescence by activating the mTOR pathway in chondrocytes from OA cartilage. Highly expressed Ob-Rb accelerates chondrocyte senescence by activating the leptin pathway in OA. Cite this article: X. Zhao, P. Huang, G. Li, L. Zhendong, G. Hu, Q. Xu. Activation of the leptin pathway by high expression of the long form of the leptin receptor (Ob-Rb) accelerates chondrocyte senescence in osteoarthritis. Bone Joint Res 2019;8:425–436. DOI: 10.1302/2046-3758.89.BJR-2018-0325.R2


Bone & Joint 360
Vol. 4, Issue 4 | Pages 27 - 29
1 Aug 2015

The August 2015 Trauma Roundup. 360 . looks at: Thromboprophylaxis not required in lower limb fractures; Subclinical thyroid dysfunction and fracture risk: moving the boundaries in fracture; Posterior wall fractures refined; Neurological injury and acetabular fracture surgery; Posterior tibial plateau fixation; Tibial plateau fractures in the longer term; Comprehensive orthogeriatric care and hip fracture; Compartment syndrome: in the eye of the beholder?


Bone & Joint Research
Vol. 10, Issue 8 | Pages 514 - 525
2 Aug 2021
Chen C Kang L Chang L Cheng T Lin S Wu S Lin Y Chuang S Lee T Chang J Ho M

Aims. Osteoarthritis (OA) is prevalent among the elderly and incurable. Intra-articular parathyroid hormone (PTH) ameliorated OA in papain-induced and anterior cruciate ligament transection-induced OA models; therefore, we hypothesized that PTH improved OA in a preclinical age-related OA model. Methods. Guinea pigs aged between six and seven months of age were randomized into control or treatment groups. Three- or four-month-old guinea pigs served as the young control group. The knees were administered 40 μl intra-articular injections of 10 nM PTH or vehicle once a week for three months. Their endurance as determined from time on the treadmill was evaluated before kill. Their tibial plateaus were analyzed using microcalculated tomography (μCT) and histological studies. Results. PTH increased the endurance on the treadmill test, preserved glycosaminoglycans, and reduced Osteoarthritis Research Society International score and chondrocyte apoptosis rate. No difference was observed in the subchondral plate bone density or metaphyseal trabecular bone volume and bone morphogenetic 2 protein staining. Conclusion. Subchondral bone is crucial in the initiation and progression of OA. Although previous studies have shown that subcutaneous PTH alleviates knee OA by improving subchondral and metaphyseal bone mass, we demonstrated that intra-articular PTH injections improved spontaneous OA by directly affecting the cartilage rather than the subchondral or metaphyseal bone in a preclinical age-related OA model. Cite this article: Bone Joint Res 2021;10(8):514–525


The Bone & Joint Journal
Vol. 97-B, Issue 6 | Pages 836 - 841
1 Jun 2015
Jónsson BY Mjöberg B

A total of 20 patients with a depressed fracture of the lateral tibial plateau (Schatzker II or III) who would undergo open reduction and internal fixation were randomised to have the metaphyseal void in the bone filled with either porous titanium granules or autograft bone. Radiographs were undertaken within one week, after six weeks, three months, six months, and after 12 months. The primary outcome measure was recurrent depression of the joint surface: a secondary outcome was the duration of surgery. The risk of recurrent depression of the joint surface was lower (p < 0.001) and the operating time less (p < 0.002) when titanium granules were used. The indication is that it is therefore beneficial to use porous titanium granules than autograft bone to fill the void created by reducing a depressed fracture of the lateral tibial plateau. There is no donor site morbidity, the operating time is shorter and the risk of recurrent depression of the articular surface is less. . Cite this article: Bone Joint J 2015; 97-B:836–41


The Bone & Joint Journal
Vol. 97-B, Issue 4 | Pages 532 - 538
1 Apr 2015
Scott CEH Davidson E MacDonald DJ White TO Keating JF

Radiological evidence of post-traumatic osteoarthritis (PTOA) after fracture of the tibial plateau is common but end-stage arthritis which requires total knee arthroplasty is much rarer. The aim of this study was to examine the indications for, and outcomes of, total knee arthroplasty after fracture of the tibial plateau and to compare this with an age and gender-matched cohort of TKAs carried out for primary osteoarthritis. Between 1997 and 2011, 31 consecutive patients (23 women, eight men) with a mean age of 65 years (40 to 89) underwent TKA at a mean of 24 months (2 to 124) after a fracture of the tibial plateau. Of these, 24 had undergone ORIF and seven had been treated non-operatively. Patients were assessed pre-operatively and at 6, 12 and > 60 months using the Short Form-12, Oxford Knee Score and a patient satisfaction score. Patients with instability or nonunion needed total knee arthroplasty earlier (14 and 13.3 months post-injury) than those with intra-articular malunion (50 months, p < 0.001). Primary cruciate-retaining implants were used in 27 (87%) patients. Complication rates were higher in the PTOA cohort and included wound complications (13% vs 1% p = 0.014) and persistent stiffness (10% vs 0%, p = 0.014). Two (6%) PTOA patients required revision total knee arthroplasty at 57 and 114 months. The mean Oxford knee score was worse pre-operatively in the cohort with primary osteoarthritis (18 vs 30, p < 0.001) but there were no significant differences in post-operative Oxford knee score or patient satisfaction (primary osteoarthritis 86%, PTOA 78%, p = 0.437). Total knee arthroplasty undertaken after fracture of the tibial plateau has a higher rate of complications than that undertaken for primary osteoarthritis, but patient-reported outcomes and satisfaction are comparable. Cite this article: Bone Joint J 2015;97-B:532–8


Bone & Joint Open
Vol. 1, Issue 9 | Pages 556 - 561
14 Sep 2020
Clough TM Shah N Divecha H Talwalkar S

Aims. The exact risk to patients undergoing surgery who develop COVID-19 is not yet fully known. This study aims to provide the current data to allow adequate consent regarding the risks of post-surgery COVID-19 infection and subsequent COVID-19-related mortality. Methods. All orthopaedic trauma cases at the Wrightington Wigan and Leigh NHS Foundation Trust from ‘lockdown’ (23 March 2020) to date (15 June 2020) were collated and split into three groups. Adult ambulatory trauma surgeries (upper limb trauma, ankle fracture, tibial plateau fracture) and regional-specific referrals (periprosthetic hip fracture) were performed at a stand-alone elective site that accepted COVID-19-negative patients. Neck of femur fractures (NOFF) and all remaining non-NOFF (paediatric trauma, long bone injury) surgeries were performed at an acute site hospital (mixed green/blue site). Patients were swabbed for COVID-19 before surgery on both sites. Age, sex, nature of surgery, American Society of Anaesthesiologists (ASA) grade, associated comorbidity, length of stay, development of post-surgical COVID-19 infection, and post-surgical COVID-19-related deaths were collected. Results. At the elective site, 225 patients underwent orthopaedic trauma surgery; two became COVID-19-positive (0.9%) in the immediate perioperative period, neither of which was fatal. At the acute site, 93 patients underwent non-NOFF trauma surgery, of whom six became COVID-19-positive (6.5%) and three died. A further 84 patients underwent NOFF surgery, seven becoming COVID-19 positive (8.3%) and five died. Conclusion. At the elective site, the rate of COVID-19 infection following orthopaedic trauma surgery was low, at 0.9%. At the acute mixed site (typical district general hospital), for non-NOFF surgery there was a 6.5% incidence of post-surgical COVID-19 infection (seven-fold higher risk) with 50% COVID-19 mortality; for NOFF surgery, there was an 8.3% incidence of post-surgical COVID-19 infection, with 71% COVID-19 mortality. This is likely to have significance when planning a resumption of elective orthopaedic surgery and for consent to the patient. Cite this article: Bone Joint Open 2020;1-9:556–561


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 2 | Pages 172 - 179
1 Feb 2008
Pinczewski LA Salmon LJ Jackson WFM von Bormann RBP Haslam PG Tashiro S

There is little evidence examining the relationship between anatomical landmarks, radiological placement of the tunnels and long-term clinical outcomes following anterior cruciate ligament (ACL) reconstruction. The aim of this study was to investigate the reproducibility of intra-operative landmarks for placement of the tunnels in single-bundle reconstruction of the ACL using four-strand hamstring tendon autografts. Isolated reconstruction of the ACL was performed in 200 patients, who were followed prospectively for seven years with use of the International Knee Documentation Committee forms and radiographs. Taking 0% as the anterior and 100% as the posterior extent, the femoral tunnel was a mean of 86% (. sd. 5) along Blumensaat’s line and the tibial tunnel was 48% (. sd. 5) along the tibial plateau. Taking 0% as the medial and 100% as the lateral extent, the tibial tunnel was 46% (. sd. 3) across the tibial plateau and the mean inclination of the graft in the coronal plane was 19° (. sd. 5.5). The use of intra-operative landmarks resulted in reproducible placement of the tunnels and an excellent clinical outcome seven years after operation. Vertical inclination was associated with increased rotational instability and degenerative radiological changes, while rupture of the graft was associated with posterior placement of the tibial tunnel. If the osseous tunnels are correctly placed, single-bundle reconstruction of the ACL adequately controls both anteroposterior and rotational instability


The Bone & Joint Journal
Vol. 101-B, Issue 1_Supple_A | Pages 53 - 58
1 Jan 2019
Billi F Kavanaugh A Schmalzried H Schmalzried TP

Aims. Loosening of the tibial component after total knee arthroplasty (TKA) is a common indication for revision. Increasing the strength of the initial tibial implant/cement interface is desirable. There is little information about the surgical techniques that lead to the highest strength. We investigated the effects of eight variables on the strength of the initial tibial baseplate/cement interface. Materials and Methods. A total of 48 tibial trays were cemented into acrylic holders using cement from two manufacturers, at three different times (early, normal, and late) using two techniques: cementing the tibial plateau or the plateau and the keel; and involving two conditions of contamination with marrow fat (at the metal/cement and cement/cement interfaces). Push-out tests were performed with load continuously recorded. Results. Compared with normal conditions, early cementing increased the mean strength of the interface when using the two cements, Simplex and Palacos, by 48% and 72%, respectively. Late cementing reduced the strength by 47% and 73%, respectively. Cementing the keel increased the mean strength by 153% and 147%, respectively, for the two cements. Contamination of the metal/cement interface with fat reduced the mean strength by 99% and 94% for the two cements but adding cement to the underside of the tibial tray prior to insertion resulted in the mean strength being lowered by only 65% and 43%, respectively. Conclusion. In order to maximize the strength of the tibial tray/cement interface, cement should be applied to the component soon after mixing, contamination of the interface should be avoided, and the keel and the plateau should be cemented


The Bone & Joint Journal
Vol. 100-B, Issue 8 | Pages 1112 - 1116
1 Aug 2018
Sinha R Weigl D Mercado E Becker T Kedem P Bar-On E

Aims. Guided growth using eight-plates is commonly used for correction of angular limb deformities in growing children. The principle is of tethering at the physeal periphery while enabling growth in the rest of the physis. The method is also applied for epiphysiodesis to correct limb-length discrepancy (LLD). Concerns have been raised regarding the potential of this method to create an epiphyseal deformity. However, this has not been investigated. The purpose of this study was to detect and quantify the occurrence of deformities in the proximal tibial epiphysis following treatment with eight-plates. Patients and Methods. A retrospective study was performed including 42 children at a mean age of 10.8 years (3.7 to 15.7) undergoing eight-plate insertion in the proximal tibia for correction of coronal plane deformities or LLD between 2007 and 2015. A total of 64 plates were inserted; 48 plates (34 patients) were inserted to correct angular deformities and 16 plates (8 patients) for LLD. Medical records, Picture Archive and Communication System images, and conventional radiographs were reviewed. Measurements included interscrew angle, lateral and medial plateau slope angles measured between the plateau surface and the line between the ends of the physis, and tibial plateau roof angle defined as 180° minus the sum of both plateau angles. Measurements were compared between radiographs performed adjacent to surgery and those at latest follow-up, and between operated and non-operated plateaus. Statistical analysis was performed using BMDP Statistical Software. Results. Slope angle increased in 31 (49.2%) of operated epiphyses by a mean of 5° (1° to 23°) compared with 29 (31.9%) in non-operated epiphyses (p = 0.043). Roof angle decreased in 29 (46.0%) of operated tibias and in 25 (27.5%) of non-operated ones by a mean of 5° (1° to 18°) (p = 0.028). Slope angle change frequency was similar in patients with LLD, varus and valgus correction (p = 0.37) but roof angle changes were slightly more frequent in LLD (p = 0.059) and correlated with the change in inter screw angles (r = 0.74, p = 0.001). Conclusion. The use of eight-plates in the proximal tibia for deformity correction and limb-length equalization causes a change in the bony morphology of the tibial plateau in a significant number of patients and the effect is more pronounced in the correction of LLD. Cite this article: Bone Joint J 2018;100-B:1112–16


Bone & Joint 360
Vol. 3, Issue 2 | Pages 9 - 12
1 Apr 2014

The April 2014 Knee Roundup. 360 . looks at: mobile compression as good as chemical thromboprophylaxis; patellar injury with MIS knee surgery; tibial plateau fracture results not as good as we thought; back and knee pain; metaphyseal sleeves may be the answer in revision knee replacement; oral tranexamic acid; gentamycin alone in antibiotic spacers; and whether the jury is still out on unloader braces


Bone & Joint 360
Vol. 3, Issue 6 | Pages 23 - 26
1 Dec 2014

The December 2014 Trauma Roundup. 360 . looks at: infection and temporising external fixation; Vitamin C in distal radial fractures; DRAFFT: Cheap and cheerful Kirschner wires win out; femoral neck fractures not as stable as they might be; displaced sacral fractures give high morbidity and mortality; sanders and calcaneal fractures: a 20-year experience; bleeding and pelvic fractures; optimising timing for acetabular fractures; and tibial plateau fractures


Bone & Joint Research
Vol. 5, Issue 8 | Pages 320 - 327
1 Aug 2016
van IJsseldijk EA Valstar ER Stoel BC Nelissen RGHH Baka N van’t Klooster R Kaptein BL

Objectives. An important measure for the diagnosis and monitoring of knee osteoarthritis is the minimum joint space width (mJSW). This requires accurate alignment of the x-ray beam with the tibial plateau, which may not be accomplished in practice. We investigate the feasibility of a new mJSW measurement method from stereo radiographs using 3D statistical shape models (SSM) and evaluate its sensitivity to changes in the mJSW and its robustness to variations in patient positioning and bone geometry. Materials and Methods. A validation study was performed using five cadaver specimens. The actual mJSW was varied and images were acquired with variation in the cadaver positioning. For comparison purposes, the mJSW was also assessed from plain radiographs. To study the influence of SSM model accuracy, the 3D mJSW measurement was repeated with models from the actual bones, obtained from CT scans. Results. The SSM-based measurement method was more robust (consistent output for a wide range of input data/consistent output under varying measurement circumstances) than the conventional 2D method, showing that the 3D reconstruction indeed reduces the influence of patient positioning. However, the SSM-based method showed comparable sensitivity to changes in the mJSW with respect to the conventional method. The CT-based measurement was more accurate than the SSM-based measurement (smallest detectable differences 0.55 mm versus 0. 82 mm, respectively). Conclusion. The proposed measurement method is not a substitute for the conventional 2D measurement due to limitations in the SSM model accuracy. However, further improvement of the model accuracy and optimisation technique can be obtained. Combined with the promising options for applications using quantitative information on bone morphology, SSM based 3D reconstructions of natural knees are attractive for further development. Cite this article: E. A. van IJsseldijk, E. R. Valstar, B. C. Stoel, R. G. H. H. Nelissen, N. Baka, R. van’t Klooster, B. L. Kaptein. Three dimensional measurement of minimum joint space width in the knee from stereo radiographs using statistical shape models. Bone Joint Res 2016;320–327. DOI: 10.1302/2046-3758.58.2000626


The Bone & Joint Journal
Vol. 96-B, Issue 7 | Pages 956 - 962
1 Jul 2014
Ahearn N Oppy A Halliday R Rowett-Harris J Morris SA Chesser TJ Livingstone JA

Unstable bicondylar tibial plateau fractures are rare and there is little guidance in the literature as to the best form of treatment. We examined the short- to medium-term outcome of this injury in a consecutive series of patients presenting to two trauma centres. Between December 2005 and May 2010, a total of 55 fractures in 54 patients were treated by fixation, 34 with peri-articular locking plates and 21 with limited access direct internal fixation in combination with circular external fixation using a Taylor Spatial Frame (TSF). At a minimum of one year post-operatively, patient-reported outcome measures including the WOMAC index and SF-36 scores showed functional deficits, although there was no significant difference between the two forms of treatment. Despite low outcome scores, patients were generally satisfied with the outcome. We achieved good clinical and radiological outcomes, with low rates of complication. In total, only three patients (5%) had collapse of the joint of > 4 mm, and metaphysis to diaphysis angulation of greater than 5º, and five patients (9%) with displacement of > 4 mm. All patients in our study went on to achieve full union. This study highlights the serious nature of this injury and generally poor patient-reported outcome measures following surgery, despite treatment by experienced surgeons using modern surgical techniques. Our findings suggest that treatment of complex bicondylar tibial plateau fractures with either a locking plate or a TSF gives similar clinical and radiological outcomes. Cite this article: Bone Joint J 2014;96-B:956–62


Bone & Joint 360
Vol. 4, Issue 6 | Pages 21 - 23
1 Dec 2015

The December 2015 Trauma Roundup. 360 . looks at: Delay to surgery in hip fracture; Hexapod fixators in the management of hypertrophic tibial nonunions; Thromboembolism after nailing pathological fractures; Tibial plateau fracture patterns under the spotlight; The health economic effects of long bone nonunion; Adverse outcomes in trauma; The sacral screw in children; Treating the contralateral SUFE


Bone & Joint 360
Vol. 2, Issue 4 | Pages 22 - 24
1 Aug 2013

The August 2013 Trauma Roundup. 360 . looks at: reverse oblique fractures do better with a cephalomedullary device; locking screws confer no advantage in tibial plateau fractures; it’s all about the radius of curvature; radius of curvature revisited; radial head replacement in complex elbow reconstruction; stem cells in early fracture haematoma; heterotrophic ossification in forearms; and Boston in perspective


The Bone & Joint Journal
Vol. 96-B, Issue 1 | Pages 59 - 64
1 Jan 2014
Weston-Simons JS Pandit H Kendrick BJL Jenkins C Barker K Dodd CAF Murray DW

Mobile-bearing unicompartmental knee replacements (UKRs) with a flat tibial plateau have not performed well in the lateral compartment, owing to a high dislocation rate. This led to the development of the Domed Lateral Oxford UKR (Domed OUKR) with a biconcave bearing. The aim of this study was to assess the survival and clinical outcomes of the Domed OUKR in a large patient cohort in the medium term. We prospectively evaluated 265 consecutive knees with isolated disease of the lateral compartment and a mean age at surgery of 64 years (32 to 90). At a mean follow-up of four years (. sd. 2.2, (0.5 to 8.3)) the mean Oxford knee score was 40 out of 48 (. sd. 7.4). A total of 12 knees (4.5%) had re-operations, of which four (1.5%) were for dislocation. All dislocations occurred in the first two years. Two (0.8%) were secondary to significant trauma that resulted in ruptured ligaments, and two (0.8%) were spontaneous. In four patients (1.5%) the UKR was converted to a primary TKR. Survival at eight years, with failure defined as any revision, was 92.1% (95% confidence interval 81.3 to 100). . The Domed Lateral OUKR gives good clinical outcomes, low re-operation and revision rates and a low dislocation rate in patients with isolated lateral compartmental disease, in the hands of the designer surgeons. Cite this article: Bone Joint J 2014;96-B:59–64


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 7 | Pages 1033 - 1040
1 Jul 2010
Nishino T Chang F Ishii T Yanai T Mishima H Ochiai N

We have previously shown that joint distraction and movement with a hinged external fixation device for 12 weeks was useful for repairing a large articular cartilage defect in a rabbit model. We have now investigated the results after six months and one year. The device was applied to 16 rabbits who underwent resection of the articular cartilage and subchondral bone from the entire tibial plateau. In group A (nine rabbits) the device was applied for six months. In group B (seven rabbits) it was in place for six months, after which it was removed and the animals were allowed to move freely for an additional six months. The cartilage remained sound in all rabbits. The areas of type II collagen-positive staining and repaired soft tissue were larger in group B than in group A. These findings provide evidence of long-term persistence of repaired cartilage with this technique and that weight-bearing has a positive effect on the quality of the cartilage


Bone & Joint Research
Vol. 5, Issue 7 | Pages 294 - 300
1 Jul 2016
Nishioka H Nakamura E Hirose J Okamoto N Yamabe S Mizuta H

Objectives. The purpose of this study was to clarify the appearance of the reparative tissue on the articular surface and to analyse the properties of the reparative tissue after hemicallotasis osteotomy (HCO) using MRI T1ρ and T2 mapping. Methods. Coronal T1ρ and T2 mapping and three-dimensional gradient-echo images were obtained from 20 subjects with medial knee osteoarthritis. We set the regions of interest (ROIs) on the full-thickness cartilage of the medial femoral condyle (MFC) and medial tibial plateau (MTP) of the knee and measured the cartilage thickness (mm) and T1ρ and T2 relaxation times (ms). Statistical analysis of time-dependent changes in the cartilage thickness and the T1ρ and T2 relaxation times was performed using one-way analysis of variance, and Scheffe’s test was employed for post hoc multiple comparison. Results. The cartilage-like repair tissue appeared on the cartilage surface of the medial compartment post-operatively, and the cartilage thickness showed a significant increase between the pre-operative and one-year post-operative time points (MFC; p = 0.003, MTP; p < 0.001). The T1ρ values of the cartilage-like repair tissue showed no difference over time, however, the T2 values showed a significant decrease between the pre-operative and one-year post-operative time points (MFC; p = 0.004, MTP; p = 0.040). Conclusion. This study clarified that the fibrocartilage-like repair tissue appeared on the articular surface of the medial compartment after HCO as evidenced by MRI T1ρ and T2 mapping. Cite this article: H. Nishioka, E. Nakamura, J. Hirose, N. Okamoto, S. Yamabe, H. Mizuta. MRI T1ρ and T2 mapping for the assessment of articular cartilage changes in patients with medial knee osteoarthritis after hemicallotasis osteotomy. Bone Joint Res 2016;5:294–300. DOI: 10.1302/2046-3758.57.BJR-2016-0057.R1


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 5 | Pages 721 - 729
1 May 2005
Yanai T Ishii T Chang F Ochiai N

We produced large full-thickness articular cartilage defects in 33 rabbits in order to evaluate the effect of joint distraction and autologous culture-expanded bone-marrow-derived mesenchymal cell transplantation (ACBMT) at 12 weeks. After fixing the knee on a hinged external fixator, we resected the entire surface of the tibial plateau. We studied three groups: 1) with and without joint distraction; 2) with joint distraction and collagen gel, and 3) with joint distraction and ACBMT and collagen gel. The histological scores were significantly higher in the groups with ACBMT collagen gel (p < 0.05). The area of regenerated soft tissue was smaller in the group allowed to bear weight (p < 0.05). These findings suggest that the repair of large defects of cartilage can be enhanced by joint distraction, collagen gel and ACBMT


The Bone & Joint Journal
Vol. 96-B, Issue 3 | Pages 325 - 331
1 Mar 2014
Dodds AL Halewood C Gupte CM Williams A Amis AA

There have been differing descriptions of the anterolateral structures of the knee, and not all have been named or described clearly. The aim of this study was to provide a clear anatomical interpretation of these structures. We dissected 40 fresh-frozen cadaveric knees to view the relevant anatomy and identified a consistent structure in 33 knees (83%); we termed this the anterolateral ligament of the knee. This structure passes antero-distally from an attachment proximal and posterior to the lateral femoral epicondyle to the margin of the lateral tibial plateau, approximately midway between Gerdy’s tubercle and the head of the fibula. The ligament is superficial to the lateral (fibular) collateral ligament proximally, from which it is distinct, and separate from the capsule of the knee. In the eight knees in which it was measured, we observed that the ligament was isometric from 0° to 60° of flexion of the knee, then slackened when the knee flexed further to 90° and was lengthened by imposing tibial internal rotation. . Cite this article: Bone Joint J 2014;96-B:325–31


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 5 | Pages 710 - 715
1 May 2005
van Huyssteen AL Hastings CJ Olesak M Hoffman EB

We reviewed 34 knees in 24 children after a double-elevating osteotomy for late-presenting infantile Blount’s disease. The mean age of patients was 9.1 years (7 to 13.5). All knees were in Langenskiöld stages IV to VI. The operative technique corrected the depression of the medial joint line by an elevating osteotomy, and the remaining tibial varus and internal torsion by an osteotomy just below the apophysis. In the more recent patients (19 knees), a proximal lateral tibial epiphysiodesis was performed at the same time. The mean pre-operative angle of depression of the medial tibial plateau of 49° (40° to 60°) was corrected to a mean of 26° (20° to 30°), which was maintained at follow-up. The femoral deformity was too small to warrant femoral osteotomy in any of our patients. The mean pre-operative mechanical varus of 30.6° (14° to 66°) was corrected to 0° to 5° of mechanical valgus in 29 knees. In five knees, there was an undercorrection of 2° to 5° of mechanical varus. At follow-up a further eight knees, in which lateral epiphysiodesis was delayed beyond five months, developed recurrent tibial varus associated with fusion of the medial proximal tibial physis


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 10 | Pages 1334 - 1340
1 Oct 2011
Nicholson JA Sutherland AG Smith FW

Abnormal knee kinematics following reconstruction of the anterior cruciate ligament may exist despite an apparent resolution of tibial laxity and functional benefit. We performed upright, weight-bearing MR scans of both knees in the sagittal plane at different angles of flexion to determine the kinematics of the knee following unilateral reconstruction (n = 12). The uninjured knee acted as a control. Scans were performed pre-operatively and at three and six months post-operatively. Anteroposterior tibial laxity was determined using an arthrometer and patient function by validated questionnaires before and after reconstruction. In all the knees with deficient anterior cruciate ligaments, the tibial plateau was displaced anteriorly and internally rotated relative to the femur when compared with the control contralateral knee, particularly in extension and early flexion (mean lateral compartment displacement: extension 7.9 mm (. sd 4.8), p = 0.002 and 30° flexion 5.1 mm (. sd.  3.6), p = 0.004). In all ten patients underwent post-operative scans. Reconstruction reduced the subluxation of the lateral tibial plateau at three months, with resolution of anterior displacement in early flexion, but not in extension (p = 0.015). At six months, the reconstructed knee again showed anterior subluxation in both the lateral (mean: extension 4.2 mm (sd 4.2), p = 0.021 and 30° flexion 3.2 mm (. sd. 3.3), p = 0.024) and medial compartments (extension, p = 0.049). . Our results show that despite improvement in laxity and functional benefit, abnormal knee kinematics remain at six months and actually deteriorate from three to six months following reconstruction of the anterior cruciate ligament


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 3 | Pages 324 - 330
1 Mar 2006
Scarvell JM Smith PN Refshauge KM Galloway HR Woods KR

This prospective study used magnetic resonance imaging to record sagittal plane tibiofemoral kinematics before and after anterior cruciate ligament reconstruction using autologous hamstring graft. Twenty patients with anterior cruciate ligament injuries, performed a closed-chain leg-press while relaxed and against a 150 N load. The tibiofemoral contact patterns between 0° to 90° of knee flexion were recorded by magnetic resonance scans. All measurements were performed pre-operatively and repeated at 12 weeks and two years. Following reconstruction there was a mean passive anterior laxity of 2.1 mm (. sd. 2.3), as measured using a KT 1000 arthrometer, and the mean Cincinnati score was 90 (. sd. 11) of 100. Pre-operatively, the medial and lateral contact patterns of the injured knees were located posteriorly on the tibial plateau compared with the healthy contralateral knees (p = 0.014), but were no longer different at 12 weeks (p = 0.117) or two years postoperatively (p = 0.909). However, both reconstructed and healthy contralateral knees showed altered kinematics over time. At two years, the contact pattern showed less posterior translation of the lateral femoral condyle during flexion (p < 0.01)


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 4 | Pages 499 - 505
1 May 2000
Uvehammer J Kärrholm J Brandsson S

We studied the kinetics of the knee in 20 patients (22 knees) 12 months after total knee arthroplasty (TKA), by using three-dimensional radiostereometry and film-exchanger techniques. Eleven knees had a concave (constrained) tibial implant and 11 a posterior-stabilised prosthesis. Eleven normal knees served as a control group. In the posterior-stabilised knees there was less proximal and posterior displacement of the centre of the tibial plateau during extension from 45° to 15°, with a decrease in the anterior translation of the femoral condyles of 4 mm at 45°. There was less internal tibial rotation and increased distal positioning of the centre of the tibial plateau with both designs when compared with the normal knees, and in both the centre of the plateau was displaced posteriorly by more than 1 cm. Increased AP translation has been recorded in all prosthetic designs so far studied by radiostereometry. The use of a posterior-stabilised design of tibial insert could reduce this translation but not to that of the normal knee


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 8 | Pages 1111 - 1115
1 Nov 2001
Nakamura E Mizuta H Kudo S Takagi K Sakamoto K

Conventional high tibial osteotomy for osteoarthritis of the medial compartment of the knee with closed-wedge or dome osteotomy (DMO) may produce shortening of the patellar tendon and loss of inclination of the proximal tibial plateau or of the offset of the tibial condyle relative to its bony axis. This can make subsequent total knee arthroplasty technically demanding. We undertook a prospective study comparing these changes after DMO with those after using open-wedge osteotomy hemicallotasis (HCO). A total of 50 knees with arthritis of the medial compartment in 46 consecutive patients was randomly allocated to either DMO or HCO. There were no significant differences between the groups with regard to age, gender, femorotibial angle before operation or the angle of correction. Radiological studies showed that HCO caused little change in the length of the patellar tendon or the inclination angle of the tibial plateau, while after DMO both gradually decreased. The degree of tibial condylar offset increased in both groups, but less so in the HCO group


Bone & Joint Research
Vol. 12, Issue 12 | Pages 734 - 746
12 Dec 2023
Chen M Hu C Hsu Y Lin Y Chen K Ueng SWN Chang Y

Aims

Therapeutic agents that prevent chondrocyte loss, extracellular matrix (ECM) degradation, and osteoarthritis (OA) progression are required. The expression level of epidermal growth factor (EGF)-like repeats and discoidin I-like domains-containing protein 3 (EDIL3) in damaged human cartilage is significantly higher than in undamaged cartilage. However, the effect of EDIL3 on cartilage is still unknown.

Methods

We used human cartilage plugs (ex vivo) and mice with spontaneous OA (in vivo) to explore whether EDIL3 has a chondroprotective effect by altering OA-related indicators.


Bone & Joint Open
Vol. 4, Issue 6 | Pages 457 - 462
26 Jun 2023
Bredgaard Jensen C Gromov K Petersen PB Jørgensen CC Kehlet H Troelsen A

Aims

Medial unicompartmental knee arthroplasty (mUKA) is an advised treatment for anteromedial knee osteoarthritis. While long-term survival after mUKA is well described, reported incidences of short-term surgical complications vary and the effect of surgical usage on complications is less established. We aimed to describe the overall occurrence and treatment of surgical complications within 90 days of mUKA, as well as occurrence in high-usage centres compared to low-usage centres.

Methods

mUKAs performed in eight fast-track centres from February 2010 to June 2018 were included from the Lundbeck Foundation Centre for Fast-track Hip and Knee Replacement Database. All readmissions within 90 days of surgery underwent chart review and readmissions related to the surgical wound or the prosthesis were recorded. Centres were categorized as high-usage centres when using mUKA in ≥ 20% of annual knee arthroplasties. The occurrence of complications between high- and low-usage centres were compared using Fisher’s exact test.


Bone & Joint Research
Vol. 11, Issue 10 | Pages 739 - 750
4 Oct 2022
Shu L Abe N Li S Sugita N

Aims

To fully quantify the effect of posterior tibial slope (PTS) angles on joint kinematics and contact mechanics of intact and anterior cruciate ligament-deficient (ACLD) knees during the gait cycle.

Methods

In this controlled laboratory study, we developed an original multiscale subject-specific finite element musculoskeletal framework model and integrated it with the tibiofemoral and patellofemoral joints with high-fidelity joint motion representations, to investigate the effects of 2.5° increases in PTS angles on joint dynamics and contact mechanics during the gait cycle.


Bone & Joint Research
Vol. 13, Issue 4 | Pages 137 - 148
1 Apr 2024
Lu Y Ho T Huang C Yeh S Chen S Tsao Y

Aims

Pigment epithelium-derived factor (PEDF) is known to induce several types of tissue regeneration by activating tissue-specific stem cells. Here, we investigated the therapeutic potential of PEDF 29-mer peptide in the damaged articular cartilage (AC) in rat osteoarthritis (OA).

Methods

Mesenchymal stem/stromal cells (MSCs) were isolated from rat bone marrow (BM) and used to evaluate the impact of 29-mer on chondrogenic differentiation of BM-MSCs in culture. Knee OA was induced in rats by a single intra-articular injection of monosodium iodoacetate (MIA) in the right knees (set to day 0). The 29-mer dissolved in 5% hyaluronic acid (HA) was intra-articularly injected into right knees at day 8 and 12 after MIA injection. Subsequently, the therapeutic effect of the 29-mer/HA on OA was evaluated by the Osteoarthritis Research Society International (OARSI) histopathological scoring system and changes in hind paw weight distribution, respectively. The regeneration of chondrocytes in damaged AC was detected by dual-immunostaining of 5-bromo-2'-deoxyuridine (BrdU) and chondrogenic markers.


Bone & Joint Research
Vol. 11, Issue 8 | Pages 518 - 527
17 Aug 2022
Hu W Lin J Wei J Yang Y Fu K Zhu T Zhu H Zheng X

Aims

To evaluate inducing osteoarthritis (OA) by surgical destabilization of the medial meniscus (DMM) in mice with and without a stereomicroscope.

Methods

Based on sample size calculation, 70 male C57BL/6 mice were randomly assigned to three surgery groups: DMM aided by a stereomicroscope; DMM by naked eye; or sham surgery. The group information was blinded to researchers. Mice underwent static weightbearing, von Frey test, and gait analysis at two-week intervals from eight to 16 weeks after surgery. Histological grade of OA was determined with the Osteoarthritis Research Society International (OARSI) scoring system.


Bone & Joint Open
Vol. 3, Issue 11 | Pages 885 - 893
14 Nov 2022
Goshima K Sawaguchi T Horii T Shigemoto K Iwai S

Aims

To evaluate whether low-intensity pulsed ultrasound (LIPUS) accelerates bone healing at osteotomy sites and promotes functional recovery after open-wedge high tibial osteotomy (OWHTO).

Methods

Overall, 90 patients who underwent OWHTO without bone grafting were enrolled in this nonrandomized retrospective study, and 45 patients treated with LIPUS were compared with 45 patients without LIPUS treatment in terms of bone healing and functional recovery postoperatively. Clinical evaluations, including the pain visual analogue scale (VAS) and Japanese Orthopaedic Association (JOA) score, were performed preoperatively as well as six weeks and three, six, and 12 months postoperatively. The progression rate of gap filling was evaluated using anteroposterior radiographs at six weeks and three, six, and 12 months postoperatively.


Bone & Joint 360
Vol. 12, Issue 2 | Pages 39 - 42
1 Apr 2023

The April 2023 Children’s orthopaedics Roundup360 looks at: Can you treat type IIA supracondylar humerus fractures conservatively?; Bone bruising and anterior cruciate ligament injury in paediatrics; Participation and motor abilities after treatment with the Ponseti method; Does fellowship training help with paediatric supracondylar fractures?; Supracondylar elbow fracture management (Supra Man): a national trainee collaborative evaluation of practice; Magnetically controlled growing rods in early-onset scoliosis; Weightbearing restrictions and weight gain in children with Perthes’ disease?; Injuries and child abuse increase during the pandemic over 12,942 emergency admissions.


Bone & Joint Open
Vol. 3, Issue 12 | Pages 991 - 997
23 Dec 2022
McPherson EJ Stavrakis AI Chowdhry M Curtin NL Dipane MV Crawford BM

Aims

Large acetabular bone defects encountered in revision total hip arthroplasty (THA) are challenging to restore. Metal constructs for structural support are combined with bone graft materials for restoration. Autograft is restricted due to limited volume, and allogenic grafts have downsides including cost, availability, and operative processing. Bone graft substitutes (BGS) are an attractive alternative if they can demonstrate positive remodelling. One potential product is a biphasic injectable mixture (Cerament) that combines a fast-resorbing material (calcium sulphate) with the highly osteoconductive material hydroxyapatite. This study reviews the application of this biomaterial in large acetabular defects.

Methods

We performed a retrospective review at a single institution of patients undergoing revision THA by a single surgeon. We identified 49 consecutive patients with large acetabular defects where the biphasic BGS was applied, with no other products added to the BGS. After placement of metallic acetabular implants, the BGS was injected into the remaining bone defects surrounding the new implants. Patients were followed and monitored for functional outcome scores, implant fixation, radiological graft site remodelling, and revision failures.


Bone & Joint 360
Vol. 13, Issue 1 | Pages 32 - 35
1 Feb 2024

The February 2024 Trauma Roundup360 looks at: Posterior malleolus fractures: what about medium-sized fragments?; Acute or delayed total hip arthroplasty after acetabular fracture fixation?; Intrawound antibiotics reduce the risk of deep infections in fracture fixation; Does the VANCO trial represent real world patients?; Can a restrictive transfusion protocol be effective beyond initial resuscitation?; What risk factors result in avascular necrosis of the talus?; Pre-existing anxiety and mood disorders have a role to play in complex regional pain syndrome; Three- and four-part proximal humeral fractures at ten years.


The Bone & Joint Journal
Vol. 105-B, Issue 3 | Pages 277 - 283
1 Mar 2023
Gausden EB Puri S Chiu Y Figgie MP Sculco TP Westrich G Sculco PK Chalmers BP

Aims

The purpose of this study was to assess mid-term survivorship following primary total knee arthroplasty (TKA) with Optetrak Logic components and identify the most common revision indications at a single institution.

Methods

We identified a retrospective cohort of 7,941 Optetrak primary TKAs performed from January 2010 to December 2018. We reviewed the intraoperative findings of 369 TKAs that required revision TKA from January 2010 to December 2021 and the details of the revision implants used. Kaplan-Meier analysis was used to determine survivorship. Cox regression analysis was used to examine the impact of patient variables and year of implantation on survival time.


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 56 - 63
1 Jan 2023
de Klerk HH Oosterhoff JHF Schoolmeesters B Nieboer P Eygendaal D Jaarsma RL IJpma FFA van den Bekerom MPJ Doornberg JN

Aims

This study aimed to answer the following questions: do 3D-printed models lead to a more accurate recognition of the pattern of complex fractures of the elbow?; do 3D-printed models lead to a more reliable recognition of the pattern of these injuries?; and do junior surgeons benefit more from 3D-printed models than senior surgeons?

Methods

A total of 15 orthopaedic trauma surgeons (seven juniors, eight seniors) evaluated 20 complex elbow fractures for their overall pattern (i.e. varus posterior medial rotational injury, terrible triad injury, radial head fracture with posterolateral dislocation, anterior (trans-)olecranon fracture-dislocation, posterior (trans-)olecranon fracture-dislocation) and their specific characteristics. First, fractures were assessed based on radiographs and 2D and 3D CT scans; and in a subsequent round, one month later, with additional 3D-printed models. Diagnostic accuracy (acc) and inter-surgeon reliability (κ) were determined for each assessment.


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1271 - 1278
1 Dec 2023
Rehman Y Korsvold AM Lerdal A Aamodt A

Aims

This study compared patient-reported outcomes of three total knee arthroplasty (TKA) designs from one manufacturer: one cruciate-retaining (CR) design, and two cruciate-sacrificing designs, anterior-stabilized (AS) and posterior-stabilized (PS).

Methods

Patients scheduled for primary TKA were included in a single-centre, prospective, three-armed, blinded randomized trial (n = 216; 72 per group). After intraoperative confirmation of posterior cruciate ligament (PCL) integrity, patients were randomly allocated to receive a CR, AS, or PS design from the same TKA system. Insertion of an AS or PS design required PCL resection. The primary outcome was the mean score of all five subscales of the Knee injury and Osteoarthritis Outcome Score (KOOS) at two-year follow-up. Secondary outcomes included all KOOS subscales, Oxford Knee Score, EuroQol five-dimension health questionnaire, EuroQol visual analogue scale, range of motion (ROM), and willingness to undergo the operation again. Patient satisfaction was also assessed.


Bone & Joint Research
Vol. 13, Issue 3 | Pages 110 - 123
7 Mar 2024
Xu J Ruan Z Guo Z Hou L Wang G Zheng Z Zhang X Liu H Sun K Guo F

Aims

Osteoarthritis (OA) is the most common chronic pathema of human joints. The pathogenesis is complex, involving physiological and mechanical factors. In previous studies, we found that ferroptosis is intimately related to OA, while the role of Sat1 in chondrocyte ferroptosis and OA, as well as the underlying mechanism, remains unclear.

Methods

In this study, interleukin-1β (IL-1β) was used to simulate inflammation and Erastin was used to simulate ferroptosis in vitro. We used small interfering RNA (siRNA) to knock down the spermidine/spermine N1-acetyltransferase 1 (Sat1) and arachidonate 15-lipoxygenase (Alox15), and examined damage-associated events including inflammation, ferroptosis, and oxidative stress of chondrocytes. In addition, a destabilization of the medial meniscus (DMM) mouse model of OA induced by surgery was established to investigate the role of Sat1 inhibition in OA progression.


Bone & Joint Open
Vol. 4, Issue 6 | Pages 463 - 471
23 Jun 2023
Baldock TE Walshaw T Walker R Wei N Scott S Trompeter AJ Eardley WGP

Aims

This is a multicentre, prospective assessment of a proportion of the overall orthopaedic trauma caseload of the UK. It investigates theatre capacity, cancellations, and time to surgery in a group of hospitals that is representative of the wider population. It identifies barriers to effective practice and will inform system improvements.

Methods

Data capture was by collaborative approach. Patients undergoing procedures from 22 August 2022 and operated on before 31 October 2022 were included. Arm one captured weekly caseload and theatre capacity. Arm two concerned patient and injury demographics, and time to surgery for specific injury groups.


Bone & Joint Open
Vol. 5, Issue 5 | Pages 374 - 384
1 May 2024
Bensa A Sangiorgio A Deabate L Illuminati A Pompa B Filardo G

Aims

Robotic-assisted unicompartmental knee arthroplasty (R-UKA) has been proposed as an approach to improve the results of the conventional manual UKA (C-UKA). The aim of this meta-analysis was to analyze the studies comparing R-UKA and C-UKA in terms of clinical outcomes, radiological results, operating time, complications, and revisions.

Methods

The literature search was conducted on three databases (PubMed, Cochrane, and Web of Science) on 20 February 2024 according to the guidelines for Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA). Inclusion criteria were comparative studies, written in the English language, with no time limitations, on the comparison of R-UKA and C-UKA. The quality of each article was assessed using the Downs and Black Checklist for Measuring Quality.


Bone & Joint Research
Vol. 11, Issue 7 | Pages 503 - 512
25 Jul 2022
Wu Y Shao Y Xie D Pan J Chen H Yao J Liang J Ke H Cai D Zeng C

Aims

To verify whether secretory leucocyte protease inhibitor (SLPI) can promote early tendon-to-bone healing after anterior cruciate ligament (ACL) reconstruction.

Methods

In vitro: the mobility of the rat bone mesenchymal stem cells (BMSCs) treated with SLPI was evaluated by scratch assay. Then the expression levels of osteogenic differentiation-related genes were analyzed by real-time quantitative PCR (qPCR) to determine the osteogenic effect of SLPI on BMSCs. In vivo: a rat model of ACL reconstruction was used to verify the effect of SLPI on tendon-to-bone healing. All the animals of the SLPI group and the negative control (NC) group were euthanized for histological evaluation, micro-CT scanning, and biomechanical testing.


Bone & Joint Research
Vol. 13, Issue 6 | Pages 279 - 293
7 Jun 2024
Morris JL Letson HL McEwen PC Dobson GP

Aims

Adenosine, lidocaine, and Mg2+ (ALM) therapy exerts differential immuno-inflammatory responses in males and females early after anterior cruciate ligament (ACL) reconstruction (ACLR). Our aim was to investigate sex-specific effects of ALM therapy on joint tissue repair and recovery 28 days after surgery.

Methods

Male (n = 21) and female (n = 21) adult Sprague-Dawley rats were randomly divided into ALM or Saline control treatment groups. Three days after ACL rupture, animals underwent ACLR. An ALM or saline intravenous infusion was commenced prior to skin incision, and continued for one hour. An intra-articular bolus of ALM or saline was also administered prior to skin closure. Animals were monitored to 28 days, and joint function, pain, inflammatory markers, histopathology, and tissue repair markers were assessed.


The Bone & Joint Journal
Vol. 105-B, Issue 5 | Pages 474 - 480
1 May 2023
Inclan PM Brophy RH

Anterior cruciate ligament (ACL) graft failure from rupture, attenuation, or malposition may cause recurrent subjective instability and objective laxity, and occurs in 3% to 22% of ACL reconstruction (ACLr) procedures. Revision ACLr is often indicated to restore knee stability, improve knee function, and facilitate return to cutting and pivoting activities. Prior to reconstruction, a thorough clinical and diagnostic evaluation is required to identify factors that may have predisposed an individual to recurrent ACL injury, appreciate concurrent intra-articular pathology, and select the optimal graft for revision reconstruction. Single-stage revision can be successful, although a staged approach may be used when optimal tunnel placement is not possible due to the position and/or widening of previous tunnels. Revision ACLr often involves concomitant procedures such as meniscal/chondral treatment, lateral extra-articular augmentation, and/or osteotomy. Although revision ACLr reliably restores knee stability and function, clinical outcomes and reoperation rates are worse than for primary ACLr.

Cite this article: Bone Joint J 2023;105-B(5):474–480.


Bone & Joint Open
Vol. 5, Issue 3 | Pages 236 - 242
22 Mar 2024
Guryel E McEwan J Qureshi AA Robertson A Ahluwalia R

Aims

Ankle fractures are common injuries and the third most common fragility fracture. In all, 40% of ankle fractures in the frail are open and represent a complex clinical scenario, with morbidity and mortality rates similar to hip fracture patients. They have a higher risk of complications, such as wound infections, malunion, hospital-acquired infections, pressure sores, veno-thromboembolic events, and significant sarcopaenia from prolonged bed rest.

Methods

A modified Delphi method was used and a group of experts with a vested interest in best practice were invited from the British Foot and Ankle Society (BOFAS), British Orthopaedic Association (BOA), Orthopaedic Trauma Society (OTS), British Association of Plastic & Reconstructive Surgeons (BAPRAS), British Geriatric Society (BGS), and the British Limb Reconstruction Society (BLRS).


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 635 - 640
1 Jun 2023
Karczewski D Siljander MP Larson DR Taunton MJ Lewallen DG Abdel MP

Aims

Knowledge on total knee arthroplasties (TKAs) in patients with a history of poliomyelitis is limited. This study compared implant survivorship and clinical outcomes among affected and unaffected limbs in patients with sequelae of poliomyelitis undergoing TKAs.

Methods

A retrospective review of our total joint registry identified 94 patients with post-polio syndrome undergoing 116 primary TKAs between January 2000 and December 2019. The mean age was 70 years (33 to 86) with 56% males (n = 65) and a mean BMI of 31 kg/m2 (18 to 49). Rotating hinge TKAs were used in 14 of 63 affected limbs (22%), but not in any of the 53 unaffected limbs. Kaplan-Meier survivorship analyses were completed. The mean follow-up was eight years (2 to 19).


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 892 - 897
1 Sep 2024
Mancino F Fontalis A Kayani B Magan A Plastow R Haddad FS

Advanced 3D imaging and CT-based navigation have emerged as valuable tools to use in total knee arthroplasty (TKA), for both preoperative planning and the intraoperative execution of different philosophies of alignment. Preoperative planning using CT-based 3D imaging enables more accurate prediction of the size of components, enhancing surgical workflow and optimizing the precision of the positioning of components. Surgeons can assess alignment, osteophytes, and arthritic changes better. These scans provide improved insights into the patellofemoral joint and facilitate tibial sizing and the evaluation of implant-bone contact area in cementless TKA. Preoperative CT imaging is also required for the development of patient-specific instrumentation cutting guides, aiming to reduce intraoperative blood loss and improve the surgical technique in complex cases. Intraoperative CT-based navigation and haptic guidance facilitates precise execution of the preoperative plan, aiming for optimal positioning of the components and accurate alignment, as determined by the surgeon’s philosophy. It also helps reduce iatrogenic injury to the periarticular soft-tissue structures with subsequent reduction in the local and systemic inflammatory response, enhancing early outcomes. Despite the increased costs and radiation exposure associated with CT-based navigation, these many benefits have facilitated the adoption of imaged based robotic surgery into routine practice. Further research on ultra-low-dose CT scans and exploration of the possible translation of the use of 3D imaging into improved clinical outcomes are required to justify its broader implementation.

Cite this article: Bone Joint J 2024;106-B(9):892–897.


The Bone & Joint Journal
Vol. 105-B, Issue 11 | Pages 1226 - 1232
1 Nov 2023
Prijs J Rawat J ten Duis K IJpma FFA Doornberg JN Jadav B Jaarsma RL

Aims

Triplane ankle fractures are complex injuries typically occurring in children aged between 12 and 15 years. Classic teaching that closure of the physis dictates the overall fracture pattern, based on studies in the 1960s, has not been challenged. The aim of this paper is to analyze whether these injuries correlate with the advancing closure of the physis with age.

Methods

A fracture mapping study was performed in 83 paediatric patients with a triplane ankle fracture treated in three trauma centres between January 2010 and June 2020. Patients aged younger than 18 years who had CT scans available were included. An independent Paediatric Orthopaedic Trauma Surgeon assessed all CT scans and classified the injuries as n-part triplane fractures. Qualitative analysis of the fracture pattern was performed using the modified Cole fracture mapping technique. The maps were assessed for both patterns and correlation with the closing of the physis until consensus was reached by a panel of six surgeons.


Bone & Joint Research
Vol. 12, Issue 8 | Pages 497 - 503
16 Aug 2023
Lee J Koh Y Kim PS Park J Kang K

Aims

Focal knee arthroplasty is an attractive alternative to knee arthroplasty for young patients because it allows preservation of a large amount of bone for potential revisions. However, the mechanical behaviour of cartilage has not yet been investigated because it is challenging to evaluate in vivo contact areas, pressure, and deformations from metal implants. Therefore, this study aimed to determine the contact pressure in the tibiofemoral joint with a focal knee arthroplasty using a finite element model.

Methods

The mechanical behaviour of the cartilage surrounding a metal implant was evaluated using finite element analysis. We modelled focal knee arthroplasty with placement flush, 0.5 mm deep, or protruding 0.5 mm with regard to the level of the surrounding cartilage. We compared contact stress and pressure for bone, implant, and cartilage under static loading conditions.


Bone & Joint Open
Vol. 5, Issue 10 | Pages 879 - 885
14 Oct 2024
Moore J van de Graaf VA Wood JA Humburg P Colyn W Bellemans J Chen DB MacDessi SJ

Aims

This study examined windswept deformity (WSD) of the knee, comparing prevalence and contributing factors in healthy and osteoarthritic (OA) cohorts.

Methods

A case-control radiological study was undertaken comparing 500 healthy knees (250 adults) with a consecutive sample of 710 OA knees (355 adults) undergoing bilateral total knee arthroplasty. The mechanical hip-knee-ankle angle (mHKA), medial proximal tibial angle (MPTA), and lateral distal femoral angle (LDFA) were determined for each knee, and the arithmetic hip-knee-ankle angle (aHKA), joint line obliquity, and Coronal Plane Alignment of the Knee (CPAK) types were calculated. WSD was defined as a varus mHKA of < -2° in one limb and a valgus mHKA of > 2° in the contralateral limb. The primary outcome was the proportional difference in WSD prevalence between healthy and OA groups. Secondary outcomes were the proportional difference in WSD prevalence between constitutional varus and valgus CPAK types, and to explore associations between predefined variables and WSD within the OA group.


Bone & Joint Research
Vol. 11, Issue 5 | Pages 252 - 259
1 May 2022
Cho BW Kang K Kwon HM Lee W Yang IH Nam JH Koh Y Park KK

Aims

This study aimed to identify the effect of anatomical tibial component (ATC) design on load distribution in the periprosthetic tibial bone of Koreans using finite element analysis (FEA).

Methods

3D finite element models of 30 tibiae in Korean women were created. A symmetric tibial component (STC, NexGen LPS-Flex) and an ATC (Persona) were used in surgical simulation. We compared the FEA measurements (von Mises stress and principal strains) around the stem tip and in the medial half of the proximal tibial bone, as well as the distance from the distal stem tip to the shortest anteromedial cortical bone. Correlations between this distance and FEA measurements were then analyzed.


Bone & Joint Open
Vol. 4, Issue 12 | Pages 914 - 922
1 Dec 2023
Sang W Qiu H Xu Y Pan Y Ma J Zhu L

Aims

Unicompartmental knee arthroplasty (UKA) is the preferred treatment for anterior medial knee osteoarthritis (OA) owing to the rapid postoperative recovery. However, the risk factors for UKA failure remain controversial.

Methods

The clinical data of Oxford mobile-bearing UKAs performed between 2011 and 2017 with a minimum follow-up of five years were retrospectively analyzed. Demographic, surgical, and follow-up data were collected. The Cox proportional hazards model was used to identify the risk factors that contribute to UKA failure. Kaplan-Meier survival was used to compare the effect of the prosthesis position on UKA survival.


The Bone & Joint Journal
Vol. 106-B, Issue 6 | Pages 632 - 638
1 Jun 2024
Hart CM Kelley BV Mamouei Z Turkmani A Ralston M Arnold M Bernthal NM Sassoon AA

Aims

Delayed postoperative inoculation of orthopaedic implants with persistent wound drainage or bacterial seeding of a haematoma can result in periprosthetic joint infection (PJI). The aim of this in vivo study was to compare the efficacy of vancomycin powder with vancomycin-eluting calcium sulphate beads in preventing PJI due to delayed inoculation.

Methods

A mouse model of PJI of the knee was used. Mice were randomized into groups with intervention at the time of surgery (postoperative day (POD) 0): a sterile control (SC; n = 6); infected control (IC; n = 15); systemic vancomycin (SV; n = 9); vancomycin powder (VP; n = 21); and vancomycin bead (VB; n = 19) groups. Delayed inoculation was introduced during an arthrotomy on POD 7 with 1 × 105 colony-forming units (CFUs) of a bioluminescent strain of Staphylococcus aureus. The bacterial burden was monitored using bioluminescence in vivo. All mice were killed on POD 21. Implants and soft-tissue were harvested and sonicated for analysis of the CFUs.


Bone & Joint Open
Vol. 5, Issue 8 | Pages 681 - 687
19 Aug 2024
van de Graaf VA Shen TS Wood JA Chen DB MacDessi SJ

Aims

Sagittal plane imbalance (SPI), or asymmetry between extension and flexion gaps, is an important issue in total knee arthroplasty (TKA). The purpose of this study was to compare SPI between kinematic alignment (KA), mechanical alignment (MA), and functional alignment (FA) strategies.

Methods

In 137 robotic-assisted TKAs, extension and flexion stressed gap laxities and bone resections were measured. The primary outcome was the proportion and magnitude of medial and lateral SPI (gap differential > 2.0 mm) for KA, MA, and FA. Secondary outcomes were the proportion of knees with severe (> 4.0 mm) SPI, and resection thicknesses for each technique, with KA as reference.


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 1000 - 1007
1 Sep 2024
Gong T Lu M Sheng H Li Z Zhou Y Luo Y Min L Tu C

Aims

Endoprosthetic reconstruction following distal femur tumour resection has been widely advocated. In this paper, we present the design of an uncemented endoprosthesis system featuring a short, curved stem, with the goal of enhancing long-term survivorship and functional outcomes.

Methods

This study involved patients who underwent implantation of an uncemented distal femoral endoprosthesis with a short and curved stem between 2014 and 2019. Functional outcomes were assessed using the 1993 version of the Musculoskeletal Tumour Society (MSTS-93) score. Additionally, we quantified five types of complications and assessed osseointegration radiologically. The survivorship of the endoprosthesis was evaluated according to two endpoints. A total of 134 patients with a median age of 26 years (IQR 16 to 41) were included in our study. The median follow-up time was 61 months (IQR 56 to 76), and the median functional MSTS-93 was 83% (IQR 73 to 91) postoperatively.


Bone & Joint Research
Vol. 11, Issue 8 | Pages 594 - 607
17 Aug 2022
Zhou Y Li J Xu F Ji E Wang C Pan Z

Aims

Osteoarthritis (OA) is a common degenerative joint disease characterized by chronic inflammatory articular cartilage degradation. Long noncoding RNAs (lncRNAs) have been previously indicated to play an important role in inflammation-related diseases. Herein, the current study set out to explore the involvement of lncRNA H19 in OA.

Methods

Firstly, OA mouse models and interleukin (IL)-1β-induced mouse chondrocytes were established. Expression patterns of IL-38 were determined in the synovial fluid and cartilage tissues from OA patients. Furthermore, the targeting relationship between lncRNA H19, tumour protein p53 (TP53), and IL-38 was determined by means of dual-luciferase reporter gene, chromatin immunoprecipitation, and RNA immunoprecipitation assays. Subsequent to gain- and loss-of-function assays, the levels of cartilage damage and proinflammatory factors were further detected using safranin O-fast green staining and enzyme-linked immunosorbent assay (ELISA) in vivo, respectively, while chondrocyte apoptosis was measured using Terminal deoxynucleotidyl transferase dUTP Nick-End Labeling (TUNEL) in vitro.


Bone & Joint Open
Vol. 4, Issue 10 | Pages 808 - 816
24 Oct 2023
Scott CEH Snowden GT Cawley W Bell KR MacDonald DJ Macpherson GJ Yapp LZ Clement ND

Aims

This prospective study reports longitudinal, within-patient, patient-reported outcome measures (PROMs) over a 15-year period following cemented single radius total knee arthroplasty (TKA). Secondary aims included reporting PROMs trajectory, 15-year implant survival, and patient attrition from follow-up.

Methods

From 2006 to 2007, 462 consecutive cemented cruciate-retaining Triathlon TKAs were implanted in 426 patients (mean age 69 years (21 to 89); 290 (62.7%) female). PROMs (12-item Short Form Survey (SF-12), Oxford Knee Score (OKS), and satisfaction) were assessed preoperatively and at one, five, ten, and 15 years. Kaplan-Meier survival and univariate analysis were performed.