The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 1 | Pages 32 - 33
1 Jan 2007
Konangamparambath S Wilkinson JM Cleveland T Stockley I

Bleeding is a major complication of revision total hip replacement. We report a case where the inflated balloon of a urinary catheter was used to temporarily control intrapelvic bleeding from the superior gluteal artery, while definitive measures for endovascular embolisation were made.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 9 | Pages 1239 - 1242
1 Sep 2007
Mitchell PD Hunt DM Lyall H Nolan M Tudor-Williams G

Panton-Valentine leukocidin secreted by Staphylococcus aureus is known to cause severe skin, soft tissue and lung infections. However, until recently it has not been described as causing life-threatening musculoskeletal infection. We present four patients suffering from osteomyelitis, septic arthritis, widespread intravascular thrombosis and overwhelming sepsis from proven Panton-Valentine leukocidin-secreting Staphylococcus aureus. Aggressive, early and repeated surgical intervention is required in the treatment of these patients.

The Panton-Valentine leukocidin toxin not only destroys host neutrophils, immunocompromising the patient, but also increases the risk of intravascular coagulopathy. This combination leads to widespread involvement of bone with glutinous pus which is difficult to drain, and makes the delivery of antibiotics and eradication of infection very difficult without surgical intervention.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 3 | Pages 337 - 342
1 Mar 2005
Kadiyala RK Ramirez A Taylor A Saltzman CL Cassell MD

We investigated the blood supply of the common peroneal nerve. Dissection of 19 lower limbs, including six with intra-vascular injection of latex, allowed gross and microscopic measurements to be made of the blood supply of the common peroneal nerve in the popliteal fossa. This showed that a long segment of the nerve in the vicinity of the fibular neck contained only a few intraneural vessels of fine calibre. By contrast, the tibial nerve received an abundant supply from a constant series of vessels arising directly from the popliteal and posterior tibial arteries.

The susceptibility of the common peroneal nerve to injury from a variety of causes and its lack of response to operative treatment may be explained by the tenuous nature of its intrinsic blood supply.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 10 | Pages 1410 - 1415
1 Oct 2010
Castagna A Randelli M Garofalo R Maradei L Giardella A Borroni M

Total shoulder replacement is a successful procedure for degenerative or some inflammatory diseases of the shoulder. However, fixation of the glenoid seems to be the main weakness with a high rate of loosening. The results using all-polyethylene components have been better than those using metal-backed components. We describe our experience with 35 consecutive total shoulder replacements using a new metal-backed glenoid component with a mean follow-up of 75.4 months (48 to 154).

Our implant differs from others because of its mechanism of fixation. It has a convex metal-backed bone interface and the main stabilising factor is a large hollow central peg. The patients were evaulated with standard radiographs and with the Constant Score, the Simple Shoulder Test and a visual analogue scale. All the scores improved and there was no loosening, no polyethylene-glenoid disassembly and no other implant-related complications.

We conclude that a metal-backed glenoid component is a good option in total shoulder replacement with no worse results than of those using a cemented all-polyethylene prosthesis.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 10 | Pages 1460 - 1465
1 Oct 2010
Rauh PB Clancy WG Jasper LE Curl LA Belkoff S Moorman CT

We evaluated two reconstruction techniques for a simulated posterolateral corner injury on ten pairs of cadaver knees. Specimens were mounted at 30° and 90° of knee flexion to record external rotation and varus movement. Instability was created by transversely sectioning the lateral collateral ligament at its midpoint and the popliteus tendon was released at the lateral femoral condyle. The left knee was randomly assigned for reconstruction using either a combined or fibula-based treatment with the right knee receiving the other. After sectioning, laxity increased in all the specimens. Each technique restored external rotatory and varus stability at both flexion angles to levels similar to the intact condition. For the fibula-based reconstruction method, varus laxity at 30° of knee flexion did not differ from the intact state, but was significantly less than after the combined method.

Both the fibula-based and combined posterolateral reconstruction techniques are equally effective in restoring stability following the simulated injury.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 4 | Pages 576 - 578
1 Apr 2010
Altaf F Derbyshire N Marshall RW

Cerebral venous sinus thrombosis is a rare condition, which is difficult to diagnose. It has not previously been reported following surgery to the cervical spine . We report such a case in a 45-year-old man after cervical disc replacement. A high index of suspicion, with early imaging of the brain and prompt treatment, can produce a favourable outcome, albeit not in this case.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 7 | Pages 943 - 947
1 Jul 2007
Wong KC Kumta SM Chiu KH Antonio GE Unwin P Leung KS

The use of a navigation system in musculoskeletal tumour surgery enables the integration of pre-operative CT and MRI images to generate a precise three-dimensional anatomical model of the site and the extent of the tumour.

We carried out six consecutive resections of musculoskeletal tumour in five patients using an existing commercial computer navigation system. There were three women and two men with a mean age of 41 years (24 to 47). Reconstruction was performed using a tumour prosthesis in three lesions and a vascularised fibular graft in one. No reconstruction was needed in two cases. The mean follow-up was 6.9 months (3.5 to 10). The mean duration of surgery was 28 minutes (13 to 50). Examination of the resected specimens showed clear margins in all the tumour lesions and a resection that was exactly as planned.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 8 | Pages 1085 - 1089
1 Aug 2010
Goddard NJ Mann HA Lee CA

Haemophilia is an x-linked inherited bleeding disorder which can cause severe arthropathy. We have reviewed the results of 70 primary total knee replacements (TKR) performed in 57 haemophilic patients between 1983 and 2007. The functional results were assessed using the Hospital for Special Surgery (HSS) knee scoring system and Kaplan-Meier survivorship analysis. Six patients died. HSS scores were available for 60 TKRs at a mean follow-up of 9.2 years (2 to 23); 57 (95%) had good or excellent results. Deep infection was recorded in one patient. Kaplan-Meier analysis using infection and aseptic loosening as endpoints showed the survival rate at 20 years to be 94.0%.

A reduction in infection, spontaneous haemarthrosis and improvement in the quality of life were noted to justify surgery in our series of patients with a mean age of 43 (25 to 70). We have found that using the latest techniques of continuous infusion of clotting Factor have significantly helped to reduce the complication rates and have achieved results which match those of the non-haemophilic population undergoing TKR.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 5 | Pages 584 - 591
1 May 2008
Karachalios T Giotikas D Roidis N Poultsides L Bargiotas K Malizos KN

We report the clinical and radiological results of a two- to three-year prospective randomised study which was designed to compare a minimally-invasive technique with a standard technique in total knee replacement and was undertaken between January 2004 and May 2007. The mini-midvastus approach was used on 50 patients (group A) and a standard approach on 50 patients (group B). The mean follow-up in both groups was 23 months (24 to 35).

The functional outcome was better in group A up to nine months after operation, as shown by statistically significant differences in the mean function score, mean total score and the mean Oxford knee score (all, p = 0.05). Patients in group A had statistically significant greater early flexion (p = 0.04) and reached their greatest mean knee flexion of 126.5° (95° to 135°) 21 days after operation. However, at final follow-up there was no significant difference in the mean maximum flexion between the groups (p = 0.08). Technical errors were identified in six patients from group A (12%) on radiological evaluation.

Based on these results, the authors currently use minimally-invasive techniques in total knee replacement in selected cases only.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 9 | Pages 1262 - 1266
1 Sep 2010
Carda S Molteni F Bertoni M Zerbinati P Invernizzi M Cisari C

This study assessed if transfer of the extensor hallucis longus is a valid alternative treatment to split transfer of the tibialis anterior tendon in adult hemiplegic patients without overactivity of the tibialis anterior.

One group of 15 patients had overactivity of tibialis anterior in the swing phase, and underwent the split transfer. A further group of 14 patients had no overactivity of tibialis anterior, and underwent transfer of extensor hallucis longus. All patients had lengthening of the tendo Achillis and tenotomies of the toe flexors. All were evaluated clinically and by three-dimensional gait analysis pre- and at one year after surgery. At this time both groups showed significant reduction of disability in walking. Gait speed, stride length and paretic propulsion had improved significantly in both groups. Dorsiflexion in the swing phase, the step length of the healthy limb and the step width improved in both groups, but only reached statistical significance in the patients with transfer of the extensor hallucis longus. There were no differences between the groups at one year after operation.

When combined with lengthening of the tendo Achillis, transfer of the extensor hallucis longus can be a valid alternative to split transfer of the tibialis anterior tendon to correct equinovarus foot deformity in patients without overactivity of tibialis anterior.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 3 | Pages 272 - 279
1 Mar 2008
Charalambous CP Stanley JK

Posterolateral rotatory instability is the most common type of symptomatic chronic instability of the elbow. In this condition the forearm complex rotates externally in relation to the humerus, causing posterior subluxation or dislocation of the radial head. The lateral ligament complex, radial head and coronoid process are important constraints to posterolateral rotatory instability, and their disruption is involved in the pathogenesis of this condition. The diagnosis relies on a high index of clinical suspicion, active and passive apprehension tests, and examination under anaesthesia. Surgical treatment has given consistently successful results. Open reconstruction of the lateral ligaments with a tendon graft has been the procedure of choice, with arthroscopic techniques emerging as a potential alternative.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 1 | Pages 1 - 11
1 Jan 2011
Murray IR Amin AK White TO Robinson CM

Most proximal humeral fractures are stable injuries of the ageing population, and can be successfully treated non-operatively. The management of the smaller number of more complex displaced fractures is more controversial and new fixation techniques have greatly increased the range of fractures that may benefit from surgery.

This article explores current concepts in the classification and clinical aspects of these injuries, reviewing the indications, innovations and outcomes for the most common methods of treatment.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 7 | Pages 911 - 914
1 Jul 2007
Khan WS Nokes L Jones RK Johnson DS

We describe the influence of the angle of immobilisation during partial weight-bearing on the forces across the extensor mechanism of the knee. Gait analysis was performed on eight healthy male subjects with the right knee in an orthotic brace locked at 0°, 10°, 20° and 30°, with the brace unlocked and also without a brace. The ground reaction force, the angle of the knee and the net external flexion movement about the knee were measured and the extensor mechanism force was calculated.

The results showed a direct non-linear relationship between the angle of knee flexion and the extensor mechanism force. When a brace was applied, the lowest forces occurred when the brace was locked at 0°. At 30° the forces approached the failure strength of some fixation devices. We recommend that for potentially unstable injuries of the extensor mechanism, when mobilising with partial weight-bearing, the knee should be flexed at no more than 10°.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 2 | Pages 284 - 285
1 Feb 2010
Lota AS Altaf F Shetty R Courtney S Mckenna P Iyer S

Necrotising fasciitis is a rare but severe infection of soft-tissue associated with rapid progression, systemic toxicity and high mortality. Monomicrobial necrotising fasciitis caused by Pseudomonas aeruginosa is exceptionally uncommon with only 12 cases reported in the literature. We describe a fatal case with an atypical presentation in a patient following spinal decompression for a metastasis from prostate cancer.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 11 | Pages 1524 - 1526
1 Nov 2006
Gardiner MD Mangwani J Williams WW

We describe a case of lumbosacral plexopathy caused by an isolated aneurysm of the common iliac artery. The patient presented with worsening low back pain, progressive numbness and weakness of the right leg in the L2-L4 distribution. This had previously been diagnosed as sciatica. A CT scan showed an aneurysm of the right common iliac artery which measured 8 cm in diameter. Despite being listed for emergency endovascular stenting, the aneurysm ruptured and the patient died.

It is important to distinguish a lumbosacral plexopathy from sciatica and to bear in mind its treatable causes which include aneurysms of the common and internal iliac arteries.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 5 | Pages 665 - 677
1 May 2011
Sköldenberg OG Salemyr MO Bodén HS Lundberg A Ahl TE Adolphson PY

Our aim in this pilot study was to evaluate the fixation of, the bone remodelling around, and the clinical outcome after surgery of a new, uncemented, fully hydroxyapatite-coated, collared and tapered femoral component, designed specifically for elderly patients with a fracture of the femoral neck.

We enrolled 50 patients, of at least 70 years of age, with an acute displaced fracture of the femoral neck in this prospective single-series study. They received a total hip replacement using the new component and were followed up regularly for two years.

Fixation was evaluated by radiostereometric analysis and bone remodelling by dual-energy x-ray absorptiometry. Hip function and the health-related quality of life were assessed using the Harris hip score and the EuroQol-5D.

Up to six weeks post-operatively there was a mean subsidence of 0.2 mm (−2.1 to +0.5) and a retroversion of a mean of 1.2° (−8.2° to +1.5°). No component migrated after three months. The patients had a continuous loss of peri-prosthetic bone which amounted to a mean of 16% (−49% to +10%) at two years. The mean Harris hip score was 82 (51 to 100) after two years.

The two-year results from this pilot study indicate that this new, uncemented femoral component can be used for elderly patients with osteoporotic fractures of the femoral neck.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 3 | Pages 336 - 342
1 Mar 2008
Cuff DJ Virani NA Levy J Frankle MA Derasari A Hines B Pupello DR Cancio M Mighell M

We retrospectively reviewed 21 patients (22 shoulders) who presented with deep infection after surgery to the shoulder, 17 having previously undergone hemiarthroplasty and five open repair of the rotator cuff. Nine shoulders had undergone previous surgical attempts to eradicate their infection. The diagnosis of infection was based on a combination of clinical suspicion (16 shoulders), positive frozen sections (> 5 polymorphonuclear leukocytes per high-power field) at the time of revision (15 shoulders), positive intra-operative cultures (18 shoulders) or the pre-operative radiological appearances. The patients were treated by an extensive debridement, intravenous antibiotics, and conversion to a reverse shoulder prosthesis in either a single- (10 shoulders) or a two-stage (12 shoulders) procedure.

At a mean follow-up of 43 months (25 to 66) there was no evidence of recurrent infection. All outcome measures showed statistically significant improvements. Mean abduction improved from 36.1° (sd 27.8) pre-operatively to 75.7° (sd 36.0) (p < 0.0001), the mean forward flexion from 43.1° (sd 33.5) to 79.5° (sd 43.2) (p = 0.0003), and mean external rotation from 10.2° (sd 18.7) to 25.4° (sd 23.5) (p = 0.0037). There was no statistically significant difference in any outcome between the single-stage and the two-stage group.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 1 | Pages 131 - 139
1 Jan 2011
Daugaard H Elmengaard B Andreassen TT Baas J Bechtold JE Soballe K

Impaction allograft is an established method of securing initial stability of an implant in arthroplasty. Subsequent bone integration can be prolonged, and the volume of allograft may not be maintained. Intermittent administration of parathyroid hormone has an anabolic effect on bone and may therefore improve integration of an implant.

Using a canine implant model we tested the hypothesis that administration of parathyroid hormone may improve osseointegration of implants surrounded by bone graft. In 20 dogs a cylindrical porous-coated titanium alloy implant was inserted into normal cancellous bone in the proximal humerus and surrounded by a circumferential gap of 2.5 mm. Morsellised allograft was impacted around the implant. Half of the animals were given daily injections of human parathyroid hormone (1–34) 5 μg/kg for four weeks and half received control injections. The two groups were compared by mechanical testing and histomorphometry. We observed a significant increase in new bone formation within the bone graft in the parathyroid hormone group. There were no significant differences in the volume of allograft, bone-implant contact or in the mechanical parameters.

These findings suggest that parathyroid hormone improves new bone formation in impacted morsellised allograft around an implant and retains the graft volume without significant resorption. Fixation of the implant was neither improved nor compromised at the final follow-up of four weeks.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 2 | Pages 286 - 288
1 Feb 2010
Yamane K Nagashima H Tanishima S Teshima R

We present the case of an 83-year-old man who developed quadriparesis and respiratory embarrassment following osteomyelitis at the occipito-atlantoaxial junction. He had developed an abscess at this site after an earlier urinary infection with methicillin-resistant staphylococcus aureus. Stabilisation of the neck and antibiotic therapy led to an almost complete neurological recovery without recourse to anterior surgery.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 3 | Pages 401 - 407
1 Mar 2005
Giannoudis PV Da Costa AA Raman R Mohamed AK Smith RM

Injury to the sciatic nerve is one of the more serious complications of acetabular fracture and traumatic dislocation of the hip, both in the short and long term. We have reviewed prospectively patients, treated in our unit, for acetabular fractures who had concomitant injury to the sciatic nerve, with the aim of predicting the functional outcome after these injuries.

Of 136 patients who underwent stabilisation of acetabular fractures, there were 27 (19.9%) with neurological injury. At initial presentation, 13 patients had a complete foot-drop, ten had weakness of the foot and four had burning pain and altered sensation over the dorsum of the foot. Serial electromyography (EMG) studies were performed and the degree of functional recovery was monitored using the grading system of the Medical Research Council. In nine patients with a foot-drop, there was evidence of a proximal acetabular (sciatic) and a distal knee (neck of fibula) nerve lesion, the double-crush syndrome.

At the final follow-up, clinical examination and EMG studies showed full recovery in five of the ten patients with initial muscle weakness, and complete resolution in all four patients with sensory symptoms (burning pain and hyperaesthesia). There was improvement of functional capacity (motor and sensory) in two patients who presented initially with complete foot-drop. In the remaining 11 with foot-drop at presentation, including all nine with the double-crush lesion, there was no improvement in function at a mean follow-up of 4.3 years.