The Bone & Joint Journal
Vol. 102-B, Issue 10 | Pages 1354 - 1358
3 Oct 2020
Noureddine H Vejsbjerg K Harrop JE White MJ Chakravarthy J Harrison JWK

Aims

In the UK, fasciectomy for Dupuytren’s contracture is generally performed under general or regional anaesthetic, with an arm tourniquet and in a hospital setting. We have changed our practice to use local anaesthetic with adrenaline, no arm tourniquet, and perform the surgery in a community setting. We present the outcome of a consecutive series of 30 patients.

Methods

Prospective data were collected for 30 patients undergoing open fasciectomy on 36 digits (six having two digits affected), over a one-year period and under the care of two surgeons. In total, 10 ml to 20 ml volume of 1% lidocaine with 1:100,000 adrenaline was used. A standard postoperative rehabilitation regime was used. Preoperative health scores, goniometer measurements of metacarpophalangeal (MCP), proximal interphalangeal (PIP) contractures, and Unité Rheumatologique des Affections de la Main (URAM) scores were measured pre- and postoperatively at six and 12 weeks.


Bone & Joint Research
Vol. 9, Issue 10 | Pages 701 - 708
1 Oct 2020
Chen X Li H Zhu S Wang Y Qian W

Aims

The diagnosis of periprosthetic joint infection (PJI) has always been challenging. Recently, D-dimer has become a promising biomarker in diagnosing PJI. However, there is controversy regarding its diagnostic value. We aim to investigate the diagnostic value of D-dimer in comparison to ESR and CRP.

Methods

PubMed, Embase, and the Cochrane Library were searched in February 2020 to identify articles reporting on the diagnostic value of D-dimer on PJI. Pooled analysis was conducted to investigate the diagnostic value of D-dimer, CRP, and ESR.


Bone & Joint 360
Vol. 9, Issue 5 | Pages 24 - 28
1 Oct 2020


The Bone & Joint Journal
Vol. 102-B, Issue 10 | Pages 1289 - 1296
1 Oct 2020
Amstutz HC Le Duff M

Aims

Hip resurfacing arthroplasty (HRA) is typically indicated for young and active patients. Due to the longevity of arthroplasty, these patients are likely to undergo revision surgery during their lifetime. There is a paucity of information on the long-term outcome of revision surgeries performed after failed HRA. The aim of our study was to provide survivorship data as well as clinical scores after HRA revisions.

Methods

A total of 42 patients (43 hips) were revised after HRA at our centre to a variety of devices, including four HRA and 39 total hip arthroplasties (THAs). In addition to perioperative complications, University of California, Los Angeles (UCLA) hip scores and 12-Item Short-Form Health Survey questionnaire (SF-12) quality of life scores were collected at follow-up visits after the primary HRA and after revision surgery.


The Bone & Joint Journal
Vol. 100-B, Issue 4 | Pages 455 - 460
1 Apr 2018
Mumith A Thomas M Shah Z Coathup M Blunn G

Increasing innovation in rapid prototyping (RP) and additive manufacturing (AM), also known as 3D printing, is bringing about major changes in translational surgical research. This review describes the current position in the use of additive manufacturing in orthopaedic surgery. Cite this article: Bone Joint J 2018;100-B:455-60


The Bone & Joint Journal
Vol. 102-B, Issue 10 | Pages 1384 - 1391
3 Oct 2020
Yoo S Jang EJ Jo J Jo JG Nam S Kim H Lee H Ryu HG

Aims

Hospital case volume is shown to be associated with postoperative outcomes in various types of surgery. However, conflicting results of volume-outcome relationship have been reported in hip fracture surgery. This retrospective cohort study aimed to evaluate the association between hospital case volume and postoperative outcomes in patients who had hip fracture surgery. We hypothesized that higher case volume would be associated with lower risk of in-hospital and one-year mortality after hip fracture surgery.

Methods

Data for all patients who underwent surgery for hip fracture from January 2008 to December 2016 were extracted from the Korean National Healthcare Insurance Service database. According to mean annual case volume of surgery for hip fracture, hospitals were classified into very low (< 30 cases/year), low (30 to 50 cases/year), intermediate (50 to 100 cases/year), high (100 to 150 cases/year), or very high (> 150 cases/year) groups. The association between hospital case volume and in-hospital mortality or one-year mortality was assessed using the logistic regression model to adjust for age, sex, type of fracture, type of anaesthesia, transfusion, comorbidities, and year of surgery.


The Bone & Joint Journal
Vol. 102-B, Issue 9 | Pages 1242 - 1247
3 Sep 2020
Hsu P Wu K Lee C Lin S Kuo KN Wang T

Aims

Guided growth has been used to treat coxa valga for cerebral palsy (CP) children. However, there has been no study on the optimal position of screw application. In this paper we have investigated the influence of screw position on the outcomes of guided growth.

Methods

We retrospectively analyzed 61 hips in 32 CP children who underwent proximal femoral hemi epiphysiodesis between July 2012 and September 2017. The hips were divided into two groups according to the transphyseal position of the screw in the coronal plane: across medial quarter (Group 1) or middle quarter (Group 2) of the medial half of the physis. We compared pre- and postoperative radiographs in head-shaft angle (HSA), Reimer’s migration percentage (MP), acetabular index (AI), and femoral anteversion angle (FAVA), as well as incidences of the physis growing-off the screw within two years. Linear and Cox regression analysis were conducted to identify factors related to HSA correction and risk of the physis growing-off the screw.


The Bone & Joint Journal
Vol. 100-B, Issue 7 | Pages 938 - 944
1 Jul 2018
Karayiannis PN Hill JC Stevenson C Finnegan S Armstrong L Beverland D

Aims. The aims of this study were to determine the indications and frequency of ordering a CT pulmonary angiography (CTPA) following primary arthroplasty of the hip and knee, and to determine the number of positive scans in these patients, the location of emboli and the outcome for patients undergoing CTPA. Patients and Methods. We analyzed the use of CTPA, as an inpatient and up to 90 days as an outpatient, in a cohort of patients and reviewed the medical records and imaging for each patient undergoing CTPA. Results. Out of 11 249 patients, scans were requested in 229 (2.04%) and 86 (38%) were positive. No patient undergoing CTPA died within 90 days. The rate of mortality from pulmonary embolism (PE) overall was 0.08%. CTPA was performed twice as often following total knee arthroplasty (TKA) compared with total hip arthroplasty (THA), and when performed was twice as likely to be positive. Hypoxia was the main indication for a scan, being the indication in 149 scans (65%); and in 23% (11 of 47), the PE was peripheral and unilateral. Three patients suffered complications resulting from therapeutic anticoagulation for possible PE, two of whom had a negative CTPA. Conclusion. CTPA is more likely to be performed following TKA compared with THA. Hypoxia was the main presenting feature of PE. A quarter of PEs which were diagnosed were unilateral and peripheral. Further study may indicate which patients who have a PE after lower limb arthroplasty require treatment, and which can avoid the complications associated with anticoagulation. Cite this article: Bone Joint J 2018;100-B:938–44


Bone & Joint Open
Vol. 1, Issue 10 | Pages 645 - 652
19 Oct 2020
Sheridan GA Hughes AJ Quinlan JF Sheehan E O'Byrne JM

Aims

We aim to objectively assess the impact of COVID-19 on mean total operative cases for all indicative procedures (as outlined by the Joint Committee on Surgical Training (JCST)) experienced by orthopaedic trainees in the deanery of the Republic of Ireland. Subjective experiences were reported for each trainee using questionnaires.

Methods

During the first four weeks of the nationwide lockdown due to COVID-19, the objective impact of the pandemic on each trainee’s surgical caseload exposure was assessed using data from individual trainee logbook profiles in the deanery of the Republic of Ireland. Independent predictor variables included the trainee grade (ST 3 to 8), the individual trainee, the unit that the logbook was reported from, and the year in which the logbook was recorded. We used the analysis of variance (ANOVA) test to assess for any statistically significant predictor variables. The subjective experience of each trainee was captured using an electronic questionnaire.


The Bone & Joint Journal
Vol. 102-B, Issue 9 | Pages 1229 - 1241
14 Sep 2020
Blom RP Hayat B Al-Dirini RMA Sierevelt I Kerkhoffs GMMJ Goslings JC Jaarsma RL Doornberg JN

Aims

The primary aim of this study was to address the hypothesis that fracture morphology might be more important than posterior malleolar fragment size in rotational type posterior malleolar ankle fractures (PMAFs). The secondary aim was to identify clinically important predictors of outcome for each respective PMAF-type, to challenge the current dogma that surgical decision-making should be based on fragment size.

Methods

This observational prospective cohort study included 70 patients with operatively treated rotational type PMAFs, respectively: 23 Haraguchi Type I (large posterolateral-oblique), 22 Type II (two-part posterolateral and posteromedial), and 25 (avulsion-) Type III. There was no standardized protocol on how to address the PMAFs and CT-imaging was used to classify fracture morphology and quality of postoperative syndesmotic reduction. Quantitative 3D-CT (Q3DCT) was used to assess the quality of fracture reduction, respectively: the proportion of articular involvement; residual intra-articular: gap, step-off, and 3D-displacement; and residual gap and step-off at the fibular notch. These predictors were correlated with the Foot and Ankle Outcome Score (FAOS) at two-years follow-up.


The Bone & Joint Journal
Vol. 100-B, Issue 11 | Pages 1493 - 1498
1 Nov 2018
Wagner ER Hevesi M Houdek MT Cofield RH Sperling JW Sanchez-Sotelo J

Aims. Patients with a failed reverse shoulder arthroplasty (RSA) have limited salvage options. The aim of this study was to determine the outcome of revision RSA when used as a salvage procedure for a failed primary RSA. Patients and Methods. We reviewed all revision RSAs performed for a failed primary RSA between 2006 and 2012, excluding patients with a follow-up of less than two years. A total of 27 revision RSAs were included in the study. The mean age of the patients at the time of revision was 70 years (58 to 82). Of the 27 patients, 14 (52% were female). The mean follow-up was 4.4 years (2 to 10). Results. Six patients (22%) developed complications requiring further revision surgery, at a mean of 1.7 years (0.1 to 5.3) postoperatively. The indication for further revision was dislocation in two, glenoid loosening in one, fracture of the humeral component in one, disassociation of the glenosphere in one, and infection in one. The five-year survival free of further revision was 85%. Five additional RSAs developed complications that did not need surgery, including dislocation in three and periprosthetic fracture in two. Overall, patients who did not require further revision had excellent pain relief, and significant improvements in elevation and external rotation of the shoulder (p < 0.01). The mean postoperative American Shoulder and Elbow Surgeons (ASES), and simple shoulder test (SST) scores were 66 and 7, respectively. Radiological results were available in 26 patients (96.3%) at a mean of 4.3 years (1.5 to 9.5). At the most recent follow-up, six patients (23%) had glenoid lucency, which were classified as grade III or higher in three (12%). Smokers had a significantly increased risk of glenoid lucency (p < 0.01). Conclusion. Revision RSA, when used to salvage a failed primary RSA, can be a successful procedure. At intermediate follow-up, survival rates are reasonable, but dislocation and glenoid lucency remain a concern, particularly in smokers. Cite this article: Bone Joint J 2018;100-B:1493–98


The Bone & Joint Journal
Vol. 102-B, Issue 9 | Pages 1210 - 1218
14 Sep 2020
Zhang H Guan L Hai Y Liu Y Ding H Chen X

Aims

The aim of this study was to use diffusion tensor imaging (DTI) to investigate changes in diffusion metrics in patients with cervical spondylotic myelopathy (CSM) up to five years after decompressive surgery. We correlated these changes with clinical outcomes as scored by the Modified Japanese Orthopedic Association (mJOA) method, Neck Disability Index (NDI), and Visual Analogue Scale (VAS).

Methods

We used multi-shot, high-resolution, diffusion tensor imaging (ms-DTI) in patients with cervical spondylotic myelopathy (CSM) to investigate the change in diffusion metrics and clinical outcomes up to five years after anterior cervical interbody discectomy and fusion (ACDF). High signal intensity was identified on T2-weighted imaging, along with DTI metrics such as fractional anisotropy (FA). MJOA, NDI, and VAS scores were also collected and compared at each follow-up point. Spearman correlations identified correspondence between FA and clinical outcome scores.


The Bone & Joint Journal
Vol. 102-B, Issue 9 | Pages 1122 - 1127
14 Sep 2020
Brown LE Fatehi A Ring D

Evidence suggests that the alleviation of pain is enhancedby a strong patient-clinician relationship and attending to a patient’s social and mental health. There is a limited role for medication, opioids in particular.

Orthopaedic surgeons can use comprehensive biopsychosocial strategies to help people recover and can work with colleagues who have the appropriate expertise in order to maximize pain alleviation with optimal opioid stewardship.

Preparing patients for elective surgery and caring for them after unplanned injury or surgery can benefit from planned and practiced strategies based in communication science.

Cite this article: Bone Joint J 2020;102-B(9):1122–1127.


The Bone & Joint Journal
Vol. 102-B, Issue 9 | Pages 1167 - 1175
14 Sep 2020
Gromov K Petersen PB Jørgensen CC Troelsen A Kehlet H

Aims

The aim of this prospective multicentre study was to describe trends in length of stay and early complications and readmissions following unicompartmental knee arthroplasty (UKA) performed at eight different centres in Denmark using a fast-track protocol and to compare the length of stay between centres with high and low utilization of UKA.

Methods

We included data from eight dedicated fast-track centres, all reporting UKAs to the same database, between 2010 and 2018. Complete ( > 99%) data on length of stay, 90-day readmission, and mortality were obtained during the study period. Specific reasons for a length of stay of > two days, length of stay > four days, and 30- and 90-day readmission were recorded. The use of UKA in the different centres was dichotomized into ≥ 20% versus < 20% of arthroplasties which were undertaken being UKAs, and ≥ 52 UKAs versus < 52 UKAs being undertaken annually.


The Bone & Joint Journal
Vol. 102-B, Issue 9 | Pages 1151 - 1157
14 Sep 2020
Levack AE McLawhorn AS Dodwell E DelPizzo K Nguyen J Sink E

Aims

Tranexamic acid (TXA) has been shown to reduce blood loss and transfusion requirements in patients undergoing orthopaedic surgery. There remains a lack of prospective evidence for the use of TXA in patients undergoing periacetabular osteotomy (PAO). The purpose of this study was to determine if intravenous (IV) TXA is effective in reducing calculated blood loss and transfusions after PAO.

Methods

This was a single-centre prospective double-blind placebo-controlled randomized trial of 81 patients aged 12 to 45 years undergoing elective PAO by a single surgeon. The intervention group (n = 40) received two doses of IV TXA of a maximum 1 g in each dose; the control group (n = 41) received two doses of 50 ml 0.9% saline IV. The primary outcome was perioperative calculated blood loss. Secondary outcomes included allogenic transfusions and six-week postoperative complications.


The Bone & Joint Journal
Vol. 99-B, Issue 4 | Pages 421 - 431
1 Apr 2017
Veldman HD Heyligers IC Grimm B Boymans TAEJ

Aims. Our aim was to prepare a systematic review and meta-analysis to compare the outcomes of cemented and cementless hemiarthroplasty of the hip, in elderly patients with a fracture of the femoral neck, to investigate the mortality, complications, length of stay in hospital, blood loss, operating time and functional results. Materials and Methods. A systematic review and meta-analysis was conducted following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines on randomised controlled trials (RCTs), studying current generation designs of stem only. The synthesis of results was done of pooled data, with a fixed effects or random effects model, based on heterogeneity. Results. A total of five RCTs including 950 patients (950 hips) were included. Cementless stems were found to be associated with more complications compared with cemented stems (odds ratio (OR) 1.61, 95% confidence interval (CI) 1.12 to 2.31, p = 0.01), especially implant-related complications (OR 3.15, 95% CI 1.55 to 6.41, p = 0.002). The operating time was shorter for cementless stems (weighted mean difference -9.96 mins, 95%CI -12.93 to -6.98, p < 0.001). The data on functional outcomes could not be pooled. There was no statistically significant difference for any other outcome between the two methods of fixation. Conclusion. In hemiarthroplasty of the hip using current generation stems, cemented stems result in fewer implant-related complications and similar mortality compared with cementless stems. Cite this article: Bone Joint J 2017;99-B:421–31


Bone & Joint Research
Vol. 5, Issue 9 | Pages 379 - 386
1 Sep 2016
Pahuta M Smolders JM van Susante JL Peck J Kim PR Beaule PE

Objectives. Alarm over the reported high failure rates for metal-on-metal (MoM) hip implants as well as their potential for locally aggressive Adverse Reactions to Metal Debris (ARMDs) has prompted government agencies, internationally, to recommend the monitoring of patients with MoM hip implants. Some have advised that a blood ion level >7 µg/L indicates potential for ARMDs. We report a systematic review and meta-analysis of the performance of metal ion testing for ARMDs. Methods. We searched MEDLINE and EMBASE to identify articles from which it was possible to reconstruct a 2 × 2 table. Two readers independently reviewed all articles and extracted data using explicit criteria. We computed a summary receiver operating curve using a Bayesian random-effects hierarchical model. Results. Our literature search returned 575 unique articles; only six met inclusion criteria defined a priori. The discriminative capacity of ion tests was homogeneous across studies but that there was substantial cut-point heterogeneity. Our best estimate of the “true” area under curve (AUC) for metal ion testing is 0.615, with a 95% credible interval of 0.480 to 0.735, thus we can state that the probability that metal ion testing is actually clinically useful with an AUC ≥ 0.75 is 1.7%. Conclusion. Metal ion levels are not useful as a screening test for identifying high risk patients because ion testing will either lead to a large burden of false positive patients, or otherwise marginally modify the pre-test probability. With the availability of more accurate non-invasive tests, we did not find any evidence for using blood ion levels to diagnose symptomatic patients. Cite this article: M. Pahuta, J. M. Smolders, J. L. van Susante, J. Peck, P. R. Kim, P. E. Beaule. Blood metal ion levels are not a useful test for adverse reactions to metal debris: a systematic review and meta-analysis. Bone Joint Res 2016;5:379–386. DOI: 10.1302/2046-3758.59.BJR-2016-0027.R1


Bone & Joint Open
Vol. 1, Issue 10 | Pages 644 - 653
14 Oct 2020
Kjærvik C Stensland E Byhring HS Gjertsen J Dybvik E Søreide O

Aims

The aim of this study was to describe variation in hip fracture treatment in Norway expressed as adherence to international and national evidence-based treatment guidelines, to study factors influencing deviation from guidelines, and to analyze consequences of non-adherence.

Methods

International and national guidelines were identified and treatment recommendations extracted. All 43 hospitals routinely treating hip fractures in Norway were characterized. From the Norwegian Hip Fracture Register (NHFR), hip fracture patients aged > 65 years and operated in the period January 2014 to December 2018 for fractures with conclusive treatment guidelines were included (n = 29,613: femoral neck fractures (n = 21,325), stable trochanteric fractures (n = 5,546), inter- and subtrochanteric fractures (n = 2,742)). Adherence to treatment recommendations and a composite indicator of best practice were analyzed. Patient survival and reoperations were evaluated for each recommendation.


Bone & Joint 360
Vol. 9, Issue 5 | Pages 3 - 3
1 Oct 2020
Ollivere B


The Bone & Joint Journal
Vol. 102-B, Issue 10 | Pages 1269 - 1270
1 Oct 2020
Haddad FS