Advertisement for orthosearch.org.uk
Results 1821 - 1840 of 2426
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 1 | Pages 32 - 36
1 Jan 2012
Nho J Lee Y Kim HJ Ha Y Suh Y Koo K

A variety of radiological methods of measuring version of the acetabular component after total hip replacement (THR) have been described. The aim of this study was to evaluate the reliability and validity of six methods (those of Lewinnek; Widmer; Hassan et al; Ackland, Bourne and Uhthoff; Liaw et al; and Woo and Morrey) that are currently in use. In 36 consecutive patients who underwent THR, version of the acetabular component was measured by three independent examiners on plain radiographs using these six methods and compared with measurements using CT scans. The intra- and interobserver reliabilities of each measurement were estimated. All measurements on both radiographs and CT scans had excellent intra- and interobserver reliability and the results from each of the six methods correlated well with the CT measurements. However, measurements made using the methods of Widmer and of Ackland, Bourne and Uhthoff were significantly different from the CT measurements (both p < 0.001), whereas measurements made using the remaining four methods were similar to the CT measurements. With regard to reliability and convergent validity, we recommend the use of the methods described by Lewinnek, Hassan et al, Liaw et al and Woo and Morrey for measurement of version of the acetabular component.


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 53 - 56
1 Nov 2013
Su EP Barrack RL

Cementless femoral stems are currently preferred for total hip replacement (THR) in the United States. Improvements in stem design, instrumentation and surgical technique have made this technology highly successful, reproducible, and applicable to the vast majority of patients requiring a THR. However, there are ongoing developments in some aspects of stem design that influence clinical results, the incidence of complications and their inherent adaptability in accommodating the needs of individual patients. Here we examine some of these design features.

Cite this article: Bone Joint J 2013;95-B, Supple A:53–6.


Bone & Joint 360
Vol. 2, Issue 6 | Pages 26 - 28
1 Dec 2013

The December 2013 Trauma Roundup360 looks at: Re-operation for intertrochanteric hip fractures; Are twin incisions better than one round the acetabulum?; Salvage osteotomy for calcaneal fractures; Posterior dislocation; Should MRSA be covered in open fractures?; Characterising the saline load test; Has it healed: hip fractures under the spotlight; and stem cells present in atrophic non-union.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 10 | Pages 1308 - 1313
1 Oct 2011
Hart AJ Sabah SA Bandi AS Maggiore P Tarassoli P Sampson B A. Skinner J

Blood metal ions have been widely used to investigate metal-on-metal hip replacements, but their ability to discriminate between well-functioning and failed hips is not known. The Medicines and Healthcare products Regulatory Agency (MHRA) has suggested a cut-off level of 7 parts per billion (ppb).

We performed a pair-matched, case-control study to investigate the sensitivity and specificity of blood metal ion levels for diagnosing failure in 176 patients with a unilateral metal-on-metal hip replacement. We recruited 88 cases with a pre-revision, unexplained failed hip and an equal number of matching controls with a well-functioning hip. We investigated the 7 ppb cut-off level for the maximum of cobalt or chromium and determined optimal mathematical cut-off levels from receiver-operating characteristic curves.

The 7 ppb cut-off level for the maximum of cobalt or chromium had a specificity of 89% and sensitivity 52% for detecting a pre-operative unexplained failed metal on metal hip replacement. The optimal cut-off level for the maximum of cobalt or chromium was 4.97 ppb and had sensitivity 63% and specificity 86%.

Blood metal ions had good discriminant ability to separate failed from well-functioning hip replacements. The MHRA cut-off level of 7 ppb provides a specific test but has poor sensitivity.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 2 | Pages 257 - 261
1 Feb 2011
Rejholec M

In late developmental dysplasia of the hip in childhood, the deformed dysplastic acetabulum is malaligned and has lost its shape due to pressure from the subluxed femoral head. The outer part of the acetabulum involves the upper part of the original acetabulum, thereby giving a bipartite appearance. A clear edge separates the outer from inner part which represents the lower part of the original acetabulum and has no direct contact with the femoral head.

Combined pelvic osteotomy (CPO) using a Lance acetabuloplasty with either a Salter or a Pemberton procedure restores the original shape and realigns the acetabulum. A total of 20 children (22 hips), with a mean age of 46 months (28 to 94) at primary operation underwent CPO with follow-up for between 12 and 132 months.

In each case concentric stable reduction with good acetabular cover was achieved and maintained throughout the period of follow-up.


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 21 - 25
1 Nov 2013
Perry KI Trousdale RT Sierra RJ

The treatment of hip dysplasia should be customised for patients individually based on radiographic findings, patient age, and the patient’s overall articular cartilage status. In many patients, restoration of hip anatomy as close to normal as possible with a PAO is the treatment of choice.

Cite this article: Bone Joint J 2013;95-B, Supple A:21–5.


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 7 - 10
1 Nov 2013
Petrie J Sassoon A Haidukewych GJ

Most hip fractures treated with modern internal fixation techniques will heal. However, failures occasionally occur and require revision procedures. Salvage strategies employed during revision are based on whether the fixation failure occurs in the femoral neck, or in the intertrochanteric region. Patient age and remaining bone stock also influence decision making. For fractures in young patients, efforts are generally focused on preserving the native femoral head via osteotomies and repeat internal fixation. For failures in older patients, some kind of hip replacement is usually selected. Disuse osteopenia, deformity, bone loss, and stress-risers from previous internal fixation devices all pose technical challenges to successful reconstruction. Attention to detail is important in order to minimise complications. In the majority of cases, good outcomes have been reported for the various salvage strategies.

Cite this article: Bone Joint J 2013;95-B, Supple A:7–10.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 11 | Pages 1571 - 1574
1 Nov 2011
Dokai T Nagashima H Nanjo Y Tanida A Teshima R

We present the case of a 15-year-old boy with symptoms due to Klippel–Feil syndrome. Radiographs and CT scans demonstrated basilar impression, occipitalisation of C1 and fusion of C2/C3. MRI showed ventral compression of the medullocervical junction. Skull traction was undertaken pre-operatively to determine whether the basilar impression could be safely reduced. During traction, the C3/C4 junction migrated 12 mm caudally and spasticity resolved. Peri-operative skull-femoral traction enabled posterior occipitocervical fixation without decompression. Following surgery, cervical alignment was restored and spasticity remained absent. One year after surgery he was not limited in his activities. The surgical strategy for patients with basilar impression and congenital anomalies remains controversial. The anterior approach with decompression is often recommended for patients with ventral compression of the medullocervical region, but such procedures are technically demanding and carry a significant risk of complications. Our surgical strategy was an alternative solution. Prior to a posterior cervical fixation, without decompression, skull traction was used to confirm that the deformity was reducible and effective in resolving associated myelopathy.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11_Supple_A | Pages 52 - 54
1 Nov 2012
Rodriguez JA Rathod PA

Large femoral heads have been used with increasing frequency over the last decade. The prime reason is likely the effect of large heads on stability. The larger head neck ratio, combined with the increased jump distance of larger heads result in a greater arc of impingement free motion, and greater resistance to dislocation in a provocative position. Multiple studies have demonstrated clear clinical efficacy in diminishing dislocation rates with the use of large femoral heads. With crosslinked polyethylene, wear has been shown to be equivalent between larger and smaller heads. However, the stability advantages of increasing diameter beyond 38 mm have not been clearly demonstrated. More importantly, recent data implicates large heads in the increasing prevalence of groin pain and psoas impingement. There are clear benefits with larger femoral head diameters, but the advantages of diameters beyond 38 mm have not yet been demonstrated clinically.


Bone & Joint 360
Vol. 2, Issue 6 | Pages 14 - 17
1 Dec 2013

The December 2013 Knee Roundup360 looks at: Conflict of interest and hyaluronic acid; Will time indeed tell in microfracture?; Contralateral knee pain and joint replacement outcomes; Patient satisfaction and knee replacement?; Hope in the cytokines for painful TKRs?; Pain severity, cytokines and osteoarthritis?; Quadriceps weakness and pain; and spontaneous osteonecrosis of the knee


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 12 | Pages 1622 - 1627
1 Dec 2010
Nathan ST Fisher BE Roberts CS

Coccydynia is a painful disorder characterised by coccygeal pain which is typically exaggerated by pressure. It remains an unsolved mystery because of the perceived unpredictability of the origin of the pain, some psychological traits that may be associated with the disorder, the presence of diverse treatment options, and varied outcomes. A more detailed classification based on the aetiology and pathoanatomy of coccydynia helps to identify patients who may benefit from conservative and surgical management.

This review focuses on the pathoanatomy, aetiology, clinical features, radiology, treatment and outcome of coccydynia.


The Bone & Joint Journal
Vol. 95-B, Issue 2 | Pages 259 - 265
1 Feb 2013
Dhawale AA Karatas AF Holmes L Rogers KJ Dabney KW Miller F

We reviewed the long-term radiological outcome, complications and revision operations in 19 children with quadriplegic cerebral palsy and hip dysplasia who underwent combined peri-iliac osteotomy and femoral varus derotation osteotomy. They had a mean age of 7.5 years (1.6 to 10.9) and comprised 22 hip dislocations and subluxations. We also studied the outcome for the contralateral hip. At a mean follow-up of 11.7 years (10 to 15.1) the Melbourne cerebral palsy (CP) hip classification was grade 2 in 16 hips, grade 3 in five, and grade 5 in one. There were five complications seen in four hips (21%, four patients), including one dislocation, one subluxation, one coxa vara with adduction deformity, one subtrochanteric fracture and one infection. A recurrent soft-tissue contracture occurred in five hips and ten required revision surgery.

In pre-adolescent children with quadriplegic cerebral palsy good long-term outcomes can be achieved after reconstruction of the hip; regular follow-up is required.

Cite this article: Bone Joint J 2013;95-B:259–65.


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 124 - 128
1 Nov 2013
Hofmann AA Shaeffer JF McCandless JB Magee TH

Isolated patellofemoral arthritis is a common condition and there are varying opinions on the most effective treatments. Non-operative and operative treatments have failed to demonstrate effective long-term treatment for those in an advanced stage of the condition. Newer designs and increased technology in patellofemoral replacement (PFR) have produced more consistent outcomes. This has led to a renewed enthusiasm for this procedure. Newer PFR prostheses have addressed the patellar maltracking issues plaguing some of the older designs. Short-term results with contemporary prostheses and new technology are described here.

Cite this article: Bone Joint J 2013;95-B, Supple A:124–8.


Bone & Joint 360
Vol. 1, Issue 2 | Pages 23 - 25
1 Apr 2012

The April 2012 Spine Roundup360 looks at yoga for lower back pain, spinal tuberculosis, complications of spinal surgery, fusing the subaxial cervical spine, minimally invasive surgery and osteoporotic vertebral fractures, spinal surgery in the over 65s, and pain relief after spinal surgery


Bone & Joint 360
Vol. 1, Issue 6 | Pages 14 - 16
1 Dec 2012

The December 2012 Foot & ankle Roundup360 looks at: correcting the overcorrected club foot; syndesmotic surgery; autograft for osteochondral defects; sesamoidectomy after fracture in athletes; complications in ankle replacement; the arthroscope as a treatment for ankle osteoarthritis; whether da Vinci was a modern foot surgeon; and a popliteal block in ankle fixation.


Bone & Joint 360
Vol. 2, Issue 6 | Pages 31 - 33
1 Dec 2013

The December 2013 Children’s orthopaedics Roundup360 looks at: Long term-changes in hip morphology following osteotomy; Arthrogrypotic wrist contractures are surgically amenable; Paediatric femoral lengthening over a nail; Current management of paediatric supracondylar fractures; MRI perfusion index predictive of Perthes’ progression; Abduction bracing effective in residual acetabular deformity; Hurler syndrome in the spotlight; and the Pavlik works for femoral fractures too!


Bone & Joint 360
Vol. 3, Issue 1 | Pages 46 - 46
1 Feb 2014

The February 2014 Research Roundup360 looks at: blood supply to the femoral head after dislocation; diabetes and hip replacement; bone remodelling over two decades following hip replacement; sham surgery as good as arthroscopic meniscectomy; distraction in knee osteoarthritis; whether joint replacement prevent cardiac events; tranexamic acid and knee replacement haemostasis; cartilage colonisation in bipolar ankle grafts; CTs and proof of fusion; atorvastatin for muscle re-innervation after sciatic nerve transection; microfracture and short-term pain in cuff repair; promising early results from L-PRF augmented cuff repairs; and fatty degeneration in a rodent model.


Bone & Joint 360
Vol. 1, Issue 6 | Pages 19 - 21
1 Dec 2012

The December 2012 Shoulder & Elbow Roundup360 looks at: whether allograft is biomechanically superior in large Hill-Sachs defects; glenoid bone loss in shoulder dislocators; repairing irreparable cuff tears; acromioclavicular joint injuries; whether more radiographs equals more surgery; whether reverse TSR is cheaper than hemiarthroplasty; autologous chondrocyte implantation in the shoulder; and fracture of the clavicle.


Bone & Joint 360
Vol. 1, Issue 6 | Pages 30 - 32
1 Dec 2012

The December 2012 Research Roundup360 looks at: whether the rheumatoid factor is just a ‘quick test’; osteonecrosis in smokers; pasteurisation effect on bone reconstruction; venous thromboembolism risk in rheumatoids; whether stem cells reverse age-related osteopenia; the effect of running on rat knees; rapid fracture healing in rats with ultrasound; magnetic stem cells; and the safety of surgery.


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 37 - 40
1 Nov 2013
Mullaji AB Shetty GM

There are few reports describing the technique of managing acetabular protrusio in primary total hip replacement. Most are small series with different methods of addressing the challenges of significant medial and proximal migration of the joint centre, deficient medial bone and reduced peripheral bony support to the acetabular component. We describe our technique and the clinical and radiological outcome of using impacted morsellised autograft with a porous-coated cementless cup in 30 primary THRs with mild (n = 8), moderate (n = 10) and severe (n = 12) grades of acetabular protrusio. The mean Harris hip score had improved from 52 pre-operatively to 85 at a mean follow-up of 4.2 years (2 to 10). At final follow-up, 27 hips (90%) had a good or excellent result, two (7%) had a fair result and one (3%) had a poor result. All bone grafts had united by the sixth post-operative month and none of the hips showed any radiological evidence of recurrence of protrusio, osteolysis or loosening. By using impacted morsellised autograft and cementless acetabular components it was possible to achieve restoration of hip mechanics, provide a biological solution to bone deficiency and ensure long-term fixation without recurrence in arthritic hips with protrusio undergoing THR.

Cite this article: Bone Joint J 2013;95-B, Supple A:37–40.