Advertisement for orthosearch.org.uk
Results 1781 - 1800 of 5020
Results per page:
The Bone & Joint Journal
Vol. 97-B, Issue 11 | Pages 1470 - 1474
1 Nov 2015
Selvarajah E Hooper G Grabowski K Frampton C Woodfield TBF Inglis G

Polyethylene wear debris can cause osteolysis and the failure of total hip arthroplasty. We present the five-year wear rates of a highly cross-linked polyethylene (X3) bearing surface when used in conjunction with a 36 mm ceramic femoral head. This was a prospective study of a cohort of 100 THAs in 93 patients. Pain and activity scores were measured pre- and post-operatively. Femoral head penetration was measured at two months, one year, two years and at five years using validated edge-detecting software (PolyWare Auto). At a mean of 5.08 years (3.93 to 6.01), 85 hips in 78 patients were available for study. The mean age of these patients was 59.08 years (42 to 73, the mean age of males (n = 34) was 59.15 years, and females (n = 44) was 59.02 years). All patients had significant improvement in their functional scores (p < 0.001). The steady state two-dimensional linear wear rate was 0.109 mm/year. The steady state volumetric wear rate was 29.61 mm. 3. /year. No significant correlation was found between rate of wear and age (p = 0.34), acetabular component size (p = 0.12) or clinical score (p = 0.74). Our study shows low steady state wear rates at five years in X3 highly cross-linked polyethylene in conjunction with a 36 mm ceramic femoral head. The linear wear rate was almost identical to the osteolysis threshold of 0.1 mm/year recommended in the literature. Cite this article: Bone Joint J 2015;97-B:1470–4


Bone & Joint Open
Vol. 1, Issue 5 | Pages 121 - 130
13 May 2020
Crosby BT Behbahani A Olujohungbe O Cottam B Perry D

Objectives

This review aims to summarize the outcomes used to describe effectiveness of treatments for paediatric wrist fractures within existing literature.

Method

We searched the Cochrane Library, Scopus, and Ovid Medline for studies pertaining to paediatric wrist fractures. Three authors independently identified and reviewed eligible studies. This resulted in a list of outcome domains and outcomes measures used within clinical research. Outcomes were mapped onto domains defined by the COMET collaborative.


The Bone & Joint Journal
Vol. 97-B, Issue 12 | Pages 1662 - 1667
1 Dec 2015
Weber-Spickschen TS Alfke D Agneskirchner JD

If a modular convertible total shoulder system is used as a primary implant for an anatomical total shoulder arthroplasty, failure of the prosthesis or the rotator cuff can be addressed by converting it to a reverse shoulder arthroplasty (RSA), with retention of the humeral stem and glenoid baseplate. This has the potential to reduce morbidity and improve the results. . In a retrospective study of 14 patients (15 shoulders) with a mean age of 70 years (47 to 83) we reviewed the clinical and radiological outcome of converting an anatomical shoulder arthroplasty (ASA) to a RSA using a convertible prosthetic system (SMR system, Lima, San Daniele, Italy). . The mean operating time was 64 minutes (45 to 75). All humeral stems and glenoid baseplates were found to be well-fixed and could be retained. There were no intra-operative or early post-operative complications and no post-operative infection. The mean follow-up was 43 months (21 to 83), by which time the mean visual analogue scale for pain had decreased from 8 pre-operatively to 1, the mean American Shoulder and Elbow Surgeons Score from 12 to 76, the mean Oxford shoulder score from 3 to 39, the mean Western Ontario Osteoarthritis of the Shoulder Score from 1618 to 418 and the mean Subjective shoulder value from 15 to 61. On radiological review, one patient had a lucency around the humeral stem, two had stress shielding. There were no fatigue fractures of the acromion but four cases of grade 1 scapular notching. . The use of a convertible prosthetic system to revise a failed ASA reduces morbidity and minimises the rate of complications. The mid-term clinical and radiological results of this technique are promising. Cite this article: Bone Joint J 2015;97-B:1662–7


The Bone & Joint Journal
Vol. 97-B, Issue 7 | Pages 890 - 898
1 Jul 2015
Renkawitz T Weber M Springorum H Sendtner E Woerner M Ulm K Weber T Grifka J

We report the kinematic and early clinical results of a patient- and observer-blinded randomised controlled trial in which CT scans were used to compare potential impingement-free range of movement (ROM) and acetabular component cover between patients treated with either the navigated ‘femur-first’ total hip arthroplasty (THA) method (n = 66; male/female 29/37, mean age 62.5 years; 50 to 74) or conventional THA (n = 69; male/female 35/34, mean age 62.9 years; 50 to 75). The Hip Osteoarthritis Outcome Score, the Harris hip score, the Euro-Qol-5D and the Mancuso THA patient expectations score were assessed at six weeks, six months and one year after surgery. A total of 48 of the patients (84%) in the navigated ‘femur-first’ group and 43 (65%) in the conventional group reached all the desirable potential ROM boundaries without prosthetic impingement for activities of daily living (ADL) in flexion, extension, abduction, adduction and rotation (p = 0.016). Acetabular component cover and surface contact with the host bone were > 87% in both groups. There was a significant difference between the navigated and the conventional groups’ Harris hip scores six weeks after surgery (p = 0.010). There were no significant differences with respect to any clinical outcome at six months and one year of follow-up. The navigated ‘femur-first’ technique improves the potential ROM for ADL without prosthetic impingement, although there was no observed clinical difference between the two treatment groups. Cite this article: Bone Joint J 2015; 97-B:890–8


The Bone & Joint Journal
Vol. 97-B, Issue 11 | Pages 1533 - 1538
1 Nov 2015
Zhang X Shao X Huang W Zhu H Yu Y

We report a new surgical technique for the treatment of traumatic dislocation of the carpometacarpal (CMC) joint of the thumb. This is a tenodesis which uses part of the flexor carpi radialis. . Between January 2010 and August 2013, 13 patients with traumatic instability of the CMC joint of the thumb were treated using this technique. The mean time interval between injury and ligament reconstruction was 13 days (0 to 42). The mean age of the patients at surgery was 38 years: all were male. . At a mean final follow-up of 26 months (24 to 29), no patient experienced any residual instability. The mean total palmar abduction of the CMC joint of the thumb was 61° and the mean radial abduction 65° The mean measurements for the uninjured hand were 66° (60° to 73°) and 68° (60° to 75°), respectively. The mean Kapandji thumb opposition score was 8.5° (8° to 9°). The mean pinch and grip strengths of the hand were 6.7 kg (3.4 to 8.2) and 40 kg (25 to 49), respectively. The mean Disabilities of the Arm, Shoulder, and Hand questionnaire score was 3 (1 to 6). Based on the Smith and Cooney score, we obtained a mean score of 85 (75 to 95), which included four excellent, seven good, and two fair results. Our technique offers an alternative method of treating traumatic dislocation of the CMC joint of the thumb: it produces a stable joint and acceptable hand function. Cite this article: Bone Joint J 2015;97-B:1533–8


The Bone & Joint Journal
Vol. 100-B, Issue 2 | Pages 233 - 241
1 Feb 2018
Ohmori T Kitamura T Nishida T Matsumoto T Tokioka T

Aim. There is not adequate evidence to establish whether external fixation (EF) of pelvic fractures leads to a reduced mortality. We used the Japan Trauma Data Bank database to identify isolated unstable pelvic ring fractures to exclude the possibility of blood loss from other injuries, and analyzed the effectiveness of EF on mortality in this group of patients. Patients and Methods. This was a registry-based comparison of 1163 patients who had been treated for an isolated unstable pelvic ring fracture with (386 patients) or without (777 patients) EF. An isolated pelvic ring fracture was defined by an Abbreviated Injury Score (AIS) for other injuries of < 3. An unstable pelvic ring fracture was defined as having an AIS ≥ 4. The primary outcome of this study was mortality. A subgroup analysis was carried out for patients who required blood transfusion within 24 hours of arrival in the Emergency Department and those who had massive blood loss (AIS code: 852610.5). Propensity-score matching was used to identify a cohort like the EF and non-EF groups. Results. With the use of propensity-score matching using the completed data, 346 patients were matched. When the propensity-score matching was adjusted, EF was associated with a significantly lower risk of death (p = 0.047). In the subgroup analysis of patients who needed blood transfusion within 24 hours and those who had massive blood loss, EF was associated with a significantly lower risk of death in patients who needed blood transfusion within 24 hours (p = 0.014) and in those with massive blood loss (p = 0.016). Conclusion. The use of EF to treat unstable pelvic ring fractures was associated with a significantly lower risk of death, especially in patients with severe fractures. Cite this article: Bone Joint J 2018;100-B:233–41


The Bone & Joint Journal
Vol. 100-B, Issue 4 | Pages 450 - 454
1 Apr 2018
Chalmers BP Mehrotra KG Sierra RJ Pagnano MW Taunton MJ Abdel MP

Aims. Primary (or spontaneous) and secondary osteonecrosis of the knee can lead to severe joint degeneration, for which either total or unicompartmental arthroplasty may be considered. However, there are limited studies analyzing outcomes of unicompartmental knee arthroplasties (UKAs) for osteonecrosis involving an isolated compartment of the knee. The aims of this study were to analyze outcomes of UKAs for osteonecrosis with specific focus on 1) survivorship free of any revision or reoperation, 2) risk factors for failure, 3) clinical outcomes, and 4) complications. Patients and Methods. A total of 45 patients underwent 46 UKAs for knee osteonecrosis between 2002 and 2014 at our institution (The Mayo Clinic, Rochester, Minnesota). Twenty patients (44%) were female; the mean age of the patients was 66 years, and mean body mass index (BMI) was 31 kg/m. 2. Of the 46 UKAs, 44 (96%) were medial UKAs, and 35 (76%) were fixed-bearing design. Mean mechanical axis postoperatively was 1.5° varus (0° to 5° varus); 41 UKAs (89%) were performed for primary osteonecrosis. Mean follow-up was five years (2 to 12). Results. Survivorship free of any revision in the cohort was 89% (95% CI 77 to 99) and 76% (95% CI 53 to 99) at five and ten years, respectively. In patients undergoing UKA for primary osteonecrosis survivorship free of any revision was 93% (95% CI 83 to 100)at both five and ten years. Secondary osteonecrosis was a significant risk factor for poorer survivorship free of any revision or reoperation (hazard ratio 7.7, p = 0.03). Three medial UKAs (6.5%) were converted to total knee arthroplasties (TKAs): two for lateral compartment degeneration and one for development of lateral osteonecrosis. No implants were revised for loosening, fracture, or wear. Knee Society scores improved from a mean of 60 (44 to 72) preoperatively to a mean of 94 postoperatively (82 to 100) (p < 0.001). There were no surgical complications. Conclusion. When done for primary osteonecrosis of the knee, UKA resulted in reliable clinical improvement, minimal complications, and durable estimated implant survivorship free of revision at ten years. UKA done for secondary osteonecrosis was substantially less durable at mid-term follow-up. Progression of knee degeneration, rather than implant failure or loosening, was most common indication for conversion to TKA. Cite this article: Bone Joint J 2018;100-B:450–4


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 31 - 35
1 Jun 2020
Sloan M Sheth NP Nelson CL

Aims

Rates of readmission and reoperation following primary total knee arthroplasty (TKA) are under scrutiny due to new payment models, which penalize these negative outcomes. Some risk factors are more modifiable than others, and some conditions considered modifiable such as obesity may not be as modifiable in the setting of advanced arthritis as many propose. We sought to determine whether controlling for hypoalbuminaemia would mitigate the effect that prior authors had identified in patients with obesity.

Methods

We reviewed the American College of Surgeons National Surgical Quality Improvement Program (ACS-NSQIP) database for the period of January 2008 to December 2016 to evaluate the rates of reoperation and readmission within 30 days following primary TKA. Multivariate logistic regression modelling controlled for preoperative albumin, age, sex, and comorbidity status.


The Bone & Joint Journal
Vol. 97-B, Issue 10 | Pages 1441 - 1444
1 Oct 2015
Hermanson M Hägglund G Riad J Rodby-Bousquet E Wagner P

Hip displacement, defined in this study as a migration percentage (MP) of more than 40%, is a common, debilitating complication of cerebral palsy (CP). In this prospective study we analysed the risk of developing hip displacement within five years of the first pelvic radiograph. . All children with CP in southern and western Sweden are invited to register in the hip surveillance programme CPUP. Inclusion criteria for the two groups in this study were children from the CPUP database born between 1994 and 2009 with Gross Motor Function Classification System (GMFCS) III to V. Group 1 included children who developed hip displacement, group 2 included children who did not develop hip displacement over a minimum follow-up of five years. A total of 145 children were included with a mean age at their initial pelvic radiograph of 3.5 years (0.6 to 9.7). The odds ratio for hip displacement was calculated for GMFCS-level, age and initial MP and head-shaft angle. A risk score was constructed with these variables using multiple logistic regression analysis. The predictive ability of the risk score was evaluated using the area under the receiver operating characteristics curve (AUC). . All variables had a significant effect on the risk of a MP > 40%. The discriminatory accuracy of the CPUP hip score is high (AUC = 0.87), indicating a high ability to differentiate between high- and low-risk individuals for hip displacement. The CPUP hip score may be useful in deciding on further follow-up and treatment in children with CP. Cite this article: Bone Joint J 2015;97-B:1441–4


The Bone & Joint Journal
Vol. 98-B, Issue 10_Supple_B | Pages 3 - 10
1 Oct 2016
Hamilton TW Pandit HG Lombardi AV Adams JB Oosthuizen CR Clavé A Dodd CAF Berend KR Murray DW

Aims. An evidence-based radiographic Decision Aid for meniscal-bearing unicompartmental knee arthroplasty (UKA) has been developed and this study investigates its performance at an independent centre. Patients and Methods. Pre-operative radiographs, including stress views, from a consecutive cohort of 550 knees undergoing arthroplasty (UKA or total knee arthroplasty; TKA) by a single-surgeon were assessed. Suitability for UKA was determined using the Decision Aid, with the assessor blinded to treatment received, and compared with actual treatment received, which was determined by an experienced UKA surgeon based on history, examination, radiographic assessment including stress radiographs, and intra-operative assessment in line with the recommended indications as described in the literature. Results. The sensitivity and specificity of the Decision Aid was 92% and 88%, respectively. Excluding knees where a clear pre-operative plan was made to perform TKA, i.e. patient request, the sensitivity was 93% and specificity 96%. The false-positive rate was low (2.4%) with all affected patients readily identifiable during joint inspection at surgery. In patients meeting Decision Aid criteria and receiving UKA, the five-year survival was 99% (95% confidence intervals (CI) 97 to 100). The false negatives (3.5%), who received UKA but did not meet the criteria, had significantly worse functional outcomes (flexion p < 0.001, American Knee Society Score - Functional p < 0.001, University of California Los Angeles score p = 0.04), and lower implant survival of 93.1% (95% CI 77.6 to 100). Conclusion. The radiographic Decision Aid safely and reliably identifies appropriate patients for meniscal-bearing UKA and achieves good results in this population. The widespread use of the Decision Aid should improve the results of UKA. Cite this article: Bone Joint J 2016;98-B(10 Suppl B):3–10


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 170 - 175
1 Jun 2020
Chalmers BP Matrka AK Sems SA Abdel MP Sierra RJ Hanssen AD Pagnano MW Mabry TM Perry KI

Aims

Arthrodesis is rarely used as a salvage procedure for patients with a chronically infected total knee arthroplasty (TKA), and little information is available about the outcome. The aim of this study was to assess the reliability, durability, and safety of this procedure as the definitive treatment for complex, chronically infected TKA, in a current series of patients.

Methods

We retrospectively identified 41 patients (41 TKAs) with a complex infected TKA, who were treated between 2002 and 2016 using a deliberate, two-stage knee arthrodesis. Their mean age was 64 years (34 to 88) and their mean body mass index (BMI) was 39 kg/m2 (25 to 79). The mean follow-up was four years (2 to 9). The extensor mechanism (EM) was deficient in 27 patients (66%) and flap cover was required in 14 (34%). Most patients were host grade B (56%) or C (29%), and limb grade 3 (71%), according to the classification of McPherson et al. A total of 12 patients (29%) had polymicrobial infections and 20 (49%) had multi-drug resistant organisms; fixation involved an intramedullary nail in 25 (61%), an external fixator in ten (24%), and dual plates in six (15%).


Bone & Joint Research
Vol. 9, Issue 6 | Pages 272 - 278
1 Jun 2020
Tapasvi S Shekhar A Patil S Pandit H

Aims

The mobile bearing Oxford unicompartmental knee arthroplasty (OUKA) is recommended to be performed with the leg in the hanging leg (HL) position, and the thigh placed in a stirrup. This comparative cadaveric study assesses implant positioning and intraoperative kinematics of OUKA implanted either in the HL position or in the supine leg (SL) position.

Methods

A total of 16 fresh-frozen knees in eight human cadavers, without macroscopic anatomical defects, were selected. The knees from each cadaver were randomized to have the OUKA implanted in the HL or SL position.


Bone & Joint 360
Vol. 9, Issue 2 | Pages 3 - 6
1 Apr 2020
Myint Y Ollivere B


The Bone & Joint Journal
Vol. 98-B, Issue 10 | Pages 1360 - 1368
1 Oct 2016
Waterson HB Clement ND Eyres KS Mandalia VI Toms AD

Aims. Our aim was to compare kinematic with mechanical alignment in total knee arthroplasty (TKA). Patients and Methods. We performed a prospective blinded randomised controlled trial to compare the functional outcome of patients undergoing TKA in mechanical alignment (MA) with those in kinematic alignment (KA). A total of 71 patients undergoing TKA were randomised to either kinematic (n = 36) or mechanical alignment (n = 35). Pre- and post-operative hip-knee-ankle radiographs were analysed. The knee injury and osteoarthritis outcome score (KOOS), American Knee Society Score, Short Form-36, Euro-Qol (EQ-5D), range of movement (ROM), two minute walk, and timed up and go tests were assessed pre-operatively and at six weeks, three and six months and one year post-operatively. Results. A total of 78% of the kinematically aligned group (28 patients) and 77% of the mechanically aligned group (27 patients) were within 3° of their pre-operative plan. There were no statistically significant differences in the mean KOOS (difference 1.3, 95% confidence interval (CI) -9.4 to 12.1, p = 0.80), EQ-5D (difference 0.8, 95% CI -7.9 to 9.6, p = 0.84), ROM (difference 0.1, 95% CI -6.0 to 6.1, p = 0.99), two minute distance tolerance (difference 20.0, 95% CI -52.8 to 92.8, p = 0.58), or timed up and go (difference 0.78, 95% CI -2.3 to 3.9, p = 0.62) between the groups at one year. Conclusion. Kinematically aligned TKAs appear to have comparable short-term results to mechanically aligned TKAs with no significant differences in function one year post-operatively. Further research is required to see if any theoretical long-term functional benefits of kinematic alignment are realised or if there are any potential effects on implant survival. Cite this article: Bone Joint J 2016;98-B:1360–8


The Bone & Joint Journal
Vol. 96-B, Issue 9 | Pages 1227 - 1233
1 Sep 2014
Phillips JRA Hopwood B Arthur C Stroud R Toms AD

A small proportion of patients have persistent pain after total knee replacement (TKR). The primary aim of this study was to record the prevalence of pain after TKR at specific intervals post-operatively and to ascertain the impact of neuropathic pain. The secondary aim was to establish any predictive factors that could be used to identify patients who were likely to have high levels of pain or neuropathic pain after TKR. . A total of 96 patients were included in the study. Their mean age was 71 years (48 to 89); 54 (56%) were female. The mean follow-up was 46 months (39 to 51). Pre-operative demographic details were recorded including a Visual Analogue Score (VAS) for pain, the Hospital Anxiety and Depression score as well as the painDETECT score for neuropathic pain. Functional outcome was assessed using the Oxford Knee score. The mean pre-operative VAS was 5.8 (1 to 10); and it improved significantly at all time periods post-operatively (p < 0.001): (from 4.5 at day three to five (1 to 10), 3.2 at six weeks (0 to 9), 2.4 at three months (0 to 7), 2.0 at six months (0 to 9), 1.7 at nine months (0 to 9), 1.5 at one year (0 to 8) and 2.0 at mean 46 months (0 to 10)). There was a high correlation (r > 0.7; p < 0.001) between the mean VAS scores for pain and the mean painDETECT scores at three months, one year and three years post-operatively. There was no correlation between the pre-operative scores and any post-operative scores at any time point. We report the prevalence of pain and neuropathic pain at various intervals up to three years after TKR. Neuropathic pain is an underestimated problem in patients with pain after TKR. It peaks at between six weeks and three-months post-operatively. However, from these data we were unable to predict which patients are most likely to be affected. Cite this article: Bone Joint J 2014;96-B:1227–33


The Bone & Joint Journal
Vol. 98-B, Issue 10_Supple_B | Pages 41 - 47
1 Oct 2016
Lisowski LA Meijer LI Bekerom MPJVD Pilot P Lisowski AE

Aims. The interest in unicompartmental knee arthroplasty (UKA) for medial osteoarthritis has increased rapidly but the long-term follow-up of the Oxford UKAs has yet to be analysed in non-designer centres. We have examined our ten- to 15-year clinical and radiological follow-up data for the Oxford Phase III UKAs. Patients and Methods. Between January 1999 and January 2005 a total of 138 consecutive Oxford Phase III arthroplasties were performed by a single surgeon in 129 patients for medial compartment osteoarthritis (71 right and 67 left knees, mean age 72.0 years (47 to 91), mean body mass index 28.2 (20.7 to 52.2)). Both clinical data and radiographs were prospectively recorded and obtained at intervals. Of the 129 patients, 32 patients (32 knees) died, ten patients (12 knees) were not able to take part in the final clinical and radiological assessment due to physical and mental conditions, but via telephone interview it was confirmed that none of these ten patients (12 knees) had a revision of the knee arthroplasty. One patient (two knees) was lost to follow-up. Results. The mean follow-up was 11.7 years (10 to 15). A total of 11 knees (8%) were revised. The survival at 15 years with revision for any reason as the endpoint was 90.6% (95% confidence interval (CI) 85.2 to 96.0) and revision related to the prosthesis was 99.3% (95% CI 97.9 to 100). The mean total Knee Society Score was 47 (0 to 80) pre-operatively and 81 (30 to 100) at latest follow-up. The mean Oxford Knee Score was 19 (12 to 40) pre-operatively and 42 (28 to 55) at final follow-up. Radiolucency beneath the tibial component occurred in 22 of 81 prostheses (27.2%) without evidence of loosening. Conclusion. This study supports the use of UKA in medial compartment osteoarthritis with excellent long-term functional and radiological outcomes with an excellent 15-year survival rate. Cite this article: Bone Joint J 2016;98-B(10 Suppl B):41–7


The Bone & Joint Journal
Vol. 96-B, Issue 8 | Pages 1062 - 1069
1 Aug 2014
Sultan MJ Zhing T Morris J Kurdy N McCollum CN

In this randomised controlled trial, we evaluated the role of elastic compression using ankle injury stockings (AIS) in the management of fractures of the ankle. A total of 90 patients with a mean age of 47 years (16 to 79) were treated within 72 hours of presentation with a fracture of the ankle, 31 of whom were treated operatively and 59 conservatively, were randomised to be treated either with compression by AIS plus an Aircast boot or Tubigrip plus an Aircast boot. Male to female ratio was 36:54. The primary outcome measure was the functional Olerud–Molander ankle score (OMAS). The secondary outcome measures were; the American Orthopaedic Foot and Ankle Society score (AOFAS); the Short Form (SF)-12v2 Quality of Life score; and the frequency of deep vein thrombosis (DVT). Compression using AIS reduced swelling of the ankle at all time points and improved the mean OMAS score at six months to 98 (95% confidence interval (CI) 96 to 99) compared with a mean of 67 (95% CI 62 to 73) for the Tubigrip group (p < 0.001). The mean AOFAS and SF-12v2 scores at six months were also significantly improved by compression. Of 86 patients with duplex imaging at four weeks, five (12%) of 43 in the AIS group and ten (23%) of 43 in the Tubigrip group developed a DVT (p = 0.26). Compression improved functional outcome and quality of life following fracture of the ankle. DVTs were frequent, but a larger study would be needed to confirm that compression with AISs reduces the incidence of DVT. . Cite this article: Bone Joint J 2014; 96-B:1062–9


The Bone & Joint Journal
Vol. 102-B, Issue 6 | Pages 716 - 726
1 Jun 2020
Scott CEH Holland G Krahelski O Murray IR Keating JF Keenan OJF

Aims

This study aims to determine the proportion of patients with end-stage knee osteoarthritis (OA) possibly suitable for partial (PKA) or combined partial knee arthroplasty (CPKA) according to patterns of full-thickness cartilage loss and anterior cruciate ligament (ACL) status.

Methods

A cross-sectional analysis of 300 consecutive patients (mean age 69 years (SD 9.5, 44 to 91), mean body mass index (BMI) 30.6 (SD 5.5, 20 to 53), 178 female (59.3%)) undergoing total knee arthroplasty (TKA) for Kellgren-Lawrence grade ≥ 3 knee OA was conducted. The point of maximal tibial bone loss on preoperative lateral radiographs was determined as a percentage of the tibial diameter. At surgery, Lachman’s test and ACL status were recorded. The presence of full-thickness cartilage loss within 16 articular surface regions (two patella, eight femoral, six tibial) was recorded.


Bone & Joint 360
Vol. 9, Issue 2 | Pages 33 - 37
1 Apr 2020


Bone & Joint 360
Vol. 9, Issue 2 | Pages 19 - 23
1 Apr 2020