To perform an incremental cost-utility analysis and assess the impact of differential costs and case volume on the cost-effectiveness of robotic arm-assisted unicompartmental knee arthroplasty (rUKA) compared to manual (mUKA). This was a five-year follow-up study of patients who were randomized to rUKA (n = 64) or mUKA (n = 65). Patients completed the EuroQol five-dimension questionnaire (EQ-5D) preoperatively, and at three months and one, two, and five years postoperatively, which was used to calculate quality-adjusted life years (QALYs) gained. Costs for the primary and additional surgery and healthcare costs were calculated.Aims
Methods
The primary objective of this study was to develop a validated classification system for assessing iatrogenic bone trauma and soft-tissue injury during total hip arthroplasty (THA). The secondary objective was to compare macroscopic bone trauma and soft-tissues injury in conventional THA (CO THA) versus robotic arm-assisted THA (RO THA) using this classification system. This study included 30 CO THAs versus 30 RO THAs performed by a single surgeon. Intraoperative photographs of the osseous acetabulum and periacetabular soft-tissues were obtained prior to implantation of the acetabular component, which were used to develop the proposed classification system. Interobserver and intraobserver variabilities of the proposed classification system were assessed.Aims
Methods
Objectives. Overlap between the distal tibia and fibula has always been quoted
to be positive. If the value is not positive then an injury to the
syndesmosis is thought to exist. Our null hypothesis is that it
is a normal variant in the adult population. Methods. We looked at axial CT scans of the ankle in 325 patients for
the presence of overlap between the distal tibia and fibula. Where
we thought this was possible we reconstructed the images to represent
a
Objectives. The goal of this study is to investigate the relation between indicators of osteoporosis (i.e., bone mineral density (BMD), and Cortical Index (CI)) and the complexity of a fracture of the proximal humerus as a result of a low-energy trauma. Methods. A retrospective chart review of 168 patients (mean age 67.2 years, range 51 to 88.7) with a fracture of the proximal humerus between 2007 and 2011, whose BMD was assessed at the Fracture Liaison Service with Dual Energy X-ray Absorptiometry (DXA) measurements of the hip, femoral neck (FN) and/or lumbar spine (LS), and whose CI and complexity of fracture were assessed on
The December 2023 Research Roundup360 looks at: Tissue integration and chondroprotective potential of acetabular labral augmentation with autograft tendon: study of a porcine model; The Irish National Orthopaedic Register under cyberattack: what happened, and what were the consequences?; An overview of machine learning in orthopaedic surgery: an educational paper; Beware of the fungus…; New evidence for COVID-19 in patients undergoing joint replacement surgery.
The August 2024 Oncology Roundup360 looks at: What factors are associated with osteoarthritis after cementation for benign aggressive bone tumour of the knee joint: a systematic review and meta-analysis; Recycled bone grafts treated with extracorporeal irradiation or liquid nitrogen freezing after malignant tumour resection; Intercalary resection of the tibia for primary bone tumours: are vascularized fibula autografts with or without allografts a durable reconstruction?; 3D-printed modular prostheses for the reconstruction of intercalary bone defects after joint-sparing limb salvage surgery for femoral diaphyseal tumours; Factors influencing the outcome of patients with primary Ewing’s sarcoma of the sacrum; The significance of surveillance imaging in children with Ewing’s sarcoma and osteosarcoma; Resection margin and soft-tissue sarcomas of the extremities treated with limb-sparing surgery and postoperative radiotherapy.
The February 2024 Knee Roundup360 looks at: Do patients with hypoallergenic total knee arthroplasty implants for metal allergy do worse? An analysis of healthcare utilizations and patient-reported outcome measures; Defining a successful total knee arthroplasty; Incidence, microbiological studies, and factors associated with periprosthetic joint infection after total knee arthroplasty; A modified Delphi consensus statement on patellar instability; Cause for concern? Significant cement coverage in retrieved metaphyseal cones after revision total knee arthroplasty; Prevalence of post-traumatic osteoarthritis after anterior cruciate ligament injury remains high despite advances in surgical techniques; Cost-effectiveness of arthroscopic partial meniscectomy versus physical therapy for traumatic meniscal tears in patients aged under 45 years.
Fixation techniques used in the treatment of slipped capital femoral epiphysis (SCFE) that allow continued growth of the femoral neck, rather than inducing epiphyseal fusion in situ, have the advantage of allowing remodelling of the deformity. The aims of this study were threefold: to assess whether the Free-Gliding (FG) SCFE screw prevents further slip; to establish whether, in practice, it enables lengthening and gliding; and to determine whether the age of the patient influences the extent of glide. All patients with SCFE who underwent fixation using FG SCFE screws after its introduction at our institution, with minimum three years’ follow-up, were reviewed retrospectively as part of ongoing governance. All pre- and postoperative radiographs were evaluated. The demographics of the patients, the grade of slip, the extent of lengthening of the barrel of the screw and the restoration of Klein’s line were recorded. Subanalysis was performed according to sex and age.Aims
Methods
This study aimed to evaluate the relationship between hip shape and mid-term function in Perthes’ disease. It also explored whether the modified three-group Stulberg classification can offer similar prognostic information to the five-group system. A total of 136 individuals aged 12 years or older who had Perthes’ disease in childhood completed the Patient-Reported Outcomes Measurement Information System (PROMIS) Mobility score (function), Nonarthritic Hip Score (NAHS) (function), EuroQol five-dimension five-level questionnaire (EQ-5D-5L) score (quality of life), and the numeric rating scale for pain (NRS). The Stulberg class of the participants’ hip radiographs were evaluated by three fellowship-trained paediatric orthopaedic surgeons. Hip shape and Stulberg class were compared to PROM scores.Aims
Methods
Anterior cruciate ligament (ACL) graft failure from rupture, attenuation, or malposition may cause recurrent subjective instability and objective laxity, and occurs in 3% to 22% of ACL reconstruction (ACLr) procedures. Revision ACLr is often indicated to restore knee stability, improve knee function, and facilitate return to cutting and pivoting activities. Prior to reconstruction, a thorough clinical and diagnostic evaluation is required to identify factors that may have predisposed an individual to recurrent ACL injury, appreciate concurrent intra-articular pathology, and select the optimal graft for revision reconstruction. Single-stage revision can be successful, although a staged approach may be used when optimal tunnel placement is not possible due to the position and/or widening of previous tunnels. Revision ACLr often involves concomitant procedures such as meniscal/chondral treatment, lateral extra-articular augmentation, and/or osteotomy. Although revision ACLr reliably restores knee stability and function, clinical outcomes and reoperation rates are worse than for primary ACLr. Cite this article:
The aim of this study was to describe the current pathways of care for patients with a fracture of the hip in five low- and middle-income countries (LMIC) in South Asia (Nepal and Sri Lanka) and Southeast Asia (Malaysia, Thailand, and the Philippines). The World Health Organization Service Availability and Readiness Assessment tool was used to collect data on the care of hip fractures in Malaysia, Thailand, the Philippines, Sri Lanka, and Nepal. Respondents were asked to provide details about the current pathway of care for patients with hip fracture, including pre-hospital transport, time to admission, time to surgery, and time to weightbearing, along with healthcare professionals involved at different stages of care, information on discharge, and patient follow-up.Aims
Methods
To propose a new method for evaluating paediatric radial neck fractures and improve the accuracy of fracture angulation measurement, particularly in younger children, and thereby facilitate planning treatment in this population. Clinical data of 117 children with radial neck fractures in our hospital from August 2014 to March 2023 were collected. A total of 50 children (26 males, 24 females, mean age 7.6 years (2 to 13)) met the inclusion criteria and were analyzed. Cases were excluded for the following reasons: Judet grade I and Judet grade IVb (> 85° angulation) classification; poor radiograph image quality; incomplete clinical information; sagittal plane angulation; severe displacement of the ulna fracture; and Monteggia fractures. For each patient, standard elbow anteroposterior (AP) view radiographs and corresponding CT images were acquired. On radiographs, Angle P (complementary to the angle between the long axis of the radial head and the line perpendicular to the physis), Angle S (complementary to the angle between the long axis of the radial head and the midline through the proximal radial shaft), and Angle U (between the long axis of the radial head and the straight line from the distal tip of the capitellum to the coronoid process) were identified as candidates approximating the true coronal plane angulation of radial neck fractures. On the coronal plane of the CT scan, the angulation of radial neck fractures (CTa) was measured and served as the reference standard for measurement. Inter- and intraobserver reliabilities were assessed by Kappa statistics and intraclass correlation coefficient (ICC).Aims
Methods
The aim of this study was to establish consensus statements on the diagnosis, nonoperative management, and indications, if any, for medial patellofemoral complex (MPFC) repair in patients with patellar instability, using the modified Delphi approach. A total of 60 surgeons from 11 countries were invited to develop consensus statements based on their expertise in this area. They were assigned to one of seven working groups defined by subtopics of interest within patellar instability. Consensus was defined as achieving between 80% and 89% agreement, strong consensus was defined as between 90% and 99% agreement, and 100% agreement was considered to be unanimous.Aims
Methods
Periprosthetic fracture and implant loosening are two of the major reasons for revision surgery of cementless implants. Optimal implant fixation with minimal bone damage is challenging in this procedure. This pilot study investigates whether vibratory implant insertion is gentler compared to consecutive single blows for acetabular component implantation in a surrogate polyurethane (PU) model. Acetabular components (cups) were implanted into 1 mm nominal under-sized cavities in PU foams (15 and 30 per cubic foot (PCF)) using a vibratory implant insertion device and an automated impaction device for single blows. The impaction force, remaining polar gap, and lever-out moment were measured and compared between the impaction methods.Aims
Methods
When performing revision total hip arthroplasty using diaphyseal-engaging titanium tapered stems (TTS), the recommended 3 to 4 cm of stem-cortical diaphyseal contact may not be available. In challenging cases such as these with only 2 cm of contact, can sufficient axial stability be achieved and what is the benefit of a prophylactic cable? This study sought to determine, first, whether a prophylactic cable allows for sufficient axial stability when the contact length is 2 cm, and second, if differing TTS taper angles (2° vs 3.5°) impact these results. A biomechanical matched-pair cadaveric study was designed using six matched pairs of human fresh cadaveric femora prepared so that 2 cm of diaphyseal bone engaged with 2° (right femora) or 3.5° (left femora) TTS. Before impaction, three matched pairs received a single 100 lb-tensioned prophylactic beaded cable; the remaining three matched pairs received no cable adjuncts. Specimens underwent stepwise axial loading to 2600 N or until failure, defined as stem subsidence > 5 mm.Aims
Methods
Total hip and knee arthroplasty (THA, TKA) are largely successful procedures; however, both have variable outcomes, resulting in some patients being dissatisfied with the outcome. Surgeons are turning to technologies such as robotic-assisted surgery in an attempt to improve outcomes. Robust studies are needed to find out if these innovations are really benefitting patients. The Robotic Arthroplasty Clinical and Cost Effectiveness Randomised Controlled Trials (RACER) trials are multicentre, patient-blinded randomized controlled trials. The patients have primary osteoarthritis of the hip or knee. The operation is Mako-assisted THA or TKA and the control groups have operations using conventional instruments. The primary clinical outcome is the Forgotten Joint Score at 12 months, and there is a built-in analysis of cost-effectiveness. Secondary outcomes include early pain, the alignment of the components, and medium- to long-term outcomes. This annotation outlines the need to assess these technologies and discusses the design and challenges when conducting such trials, including surgical workflows, isolating the effect of the operation, blinding, and assessing the learning curve. Finally, the future of robotic surgery is discussed, including the need to contemporaneously introduce and evaluate such technologies. Cite this article:
Robotic-assisted total knee arthroplasty (TKA) has proven higher accuracy, fewer alignment outliers, and improved short-term clinical outcomes when compared to conventional TKA. However, evidence of cost-effectiveness and individual superiority of one system over another is the subject of further research. Despite its growing adoption rate, published results are still limited and comparative studies are scarce. This review compares characteristics and performance of five currently available systems, focusing on the information and feedback each system provides to the surgeon, what the systems allow the surgeon to modify during the operation, and how each system then aids execution of the surgical plan. Cite this article: Abstract