The October 2014 Children’s orthopaedics Roundup360 looks at: spondylolisthesis management strategies; not all cervical collars are even; quality of life with Legg-Calve-Perthe’s disease; femoral shaft fractures in children; percutaneous trigger thumb release – avoid at all costs in children; predicting repeat surgical intervention in acute osteomyelitis; and C-Arm position inconsequential in radiation exposure
In recent years, the plantaris tendon has been
implicated in the development of chronic painful mid-portion Achilles tendinopathy.
In some cases, a thickened plantaris tendon is closely associated
with the Achilles tendon, and surgical excision of the plantaris
tendon has been reported to be curative in patients who have not
derived benefit following conservative treatment and surgical interventions. The aim of this review is to outline the basic aspects of, and
the recent research findings, related to the plantaris tendon, covering
anatomical and clinical studies including those dealing with histology,
imaging and treatment. Cite this article
Fractures of the distal femur are an important cause of morbidity.
Their optimal management remains controversial. Contemporary implants
include angular-stable anatomical locking plates and locked intramedullary
nails (IMNs). We compared the long-term patient-reported functional
outcome of fixation of fractures of the distal femur using these
two methods of treatment. A total of 297 patients were retrospectively identified from
a State-wide trauma registry in Australia: 195 had been treated
with a locking plate and 102 with an IMN. Baseline characteristics
of the patients and their fractures were recorded. Health-related
quality-of-life, functional and radiographic outcomes were compared
using mixed effects regression models at six months and one year.Aims
Patients and Methods
In order to achieve satisfactory reduction of
complex distal humeral fractures, adequate exposure of the fracture fragments
and the joint surface is required. Several surgical exposures have
been described for distal humeral fractures. We report our experience
using the anconeus pedicle olecranon flip osteotomy approach. This
involves detachment of the triceps along with a sliver of olecranon,
which retains the anconeus pedicle. We report the use of this approach
in ten patients (six male, four female) with a mean age of 38.4
years (28 to 51). The mean follow-up was 15 months (12 to 18) with
no loss to follow-up. Elbow function was graded using the Mayo Score.
The results were excellent in four patients, good in five and fair
in one patient. The mean time to both fracture and osteotomy union
was 10.6 weeks (8 to 12) and 7.1 weeks (6 to 8), respectively. We
found this approach gave reliably good exposure for these difficult
fractures enabling anatomical reduction and bicondylar plating without
complications. Cite this article:
Between 1987 and 2006 we performed a modified Thompson’s quadricepsplasty on 40 fracture-related stiff knees and followed the patients for a mean of 7.9 years (2 to 11.1). The factors affecting the final gain of movement were investigated. A total of 15 knees required lengthening of the rectus femoris. The mean flexion gain was 70.2° (42.3° to 112.5°). According to Judet’s criteria, the results were excellent in 30 knees, good in seven, and fair in three. The range of movement which was achieved intra-operatively was related to the gain of knee flexion on univariate analysis. Five patients had complications: deep infection in one, recurrent patellar dislocation in one, and rupture of the extensor mechanism in three. This modified technique gives satisfactory results. Achieving maximum knee flexion intra-operatively seems to be the most important factor in enhancing the outcome in patients with stiffness of the knee following fracture.
We have observed clinical cases where bone is formed in the overlaying muscle covering surgically created bone defects treated with a hydroxyapatite/calcium sulphate biomaterial. Our objective was to investigate the osteoinductive potential of the biomaterial and to determine if growth factors secreted from local bone cells induce osteoblastic differentiation of muscle cells. We seeded mouse skeletal muscle cells C2C12 on the hydroxyapatite/calcium sulphate biomaterial and the phenotype of the cells was analysed. To mimic surgical conditions with leakage of extra cellular matrix (ECM) proteins and growth factors, we cultured rat bone cells ROS 17/2.8 in a bioreactor and harvested the secreted proteins. The secretome was added to rat muscle cells L6. The phenotype of the muscle cells after treatment with the media was assessed using immunostaining and light microscopy.Objectives
Materials and Methods
The purpose of this paper is to discuss the risk
factors, prevention strategies, classification, and treatment of
intra-operative femur fractures sustained during primary and revision
total hip arthroplasty.
Single event multilevel surgery (SEMLS) has been shown to improve
gait in children with cerebral palsy (CP). However, there is limited
evidence regarding long-term outcomes and factors influencing them. In total 39 children (17 females and 22 males; mean age at SEMLS
ten years four months, standard deviation 37 months) with bilateral
CP (20 Gross Motor Function Classification System (GMFCS) level
II and 19 GMFCS level III) treated with SEMLS were included. Children
were evaluated using gait analysis and the Gait Deviation Index
(GDI) before SEMLS and one, two to three, five and at least ten
years after SEMLS. A linear mixed model was used to estimate the
effect of age at the surgery, GMFCS and follow-up period on GDI. Aims
Methods
We reviewed 22 children with cubitus varus who had been treated by a reverse V osteotomy and fixation by cross-pinning and wiring. The mean pre-operative humeral-elbow-wrist angle was −16.9° (−25° to +9°) and at the latest follow-up it was +7.3° (−2° to +14°). No child had a lateral prominence greater than 5 mm after correction. An excellent result was achieved in 20 children and a good result in two. We believe that this osteotomy has the advantages of better inherent stability, the avoidance of a prominent lateral condyle after correction and firm fixation allowing early movement.
Failed internal fixation of a fracture of the
proximal humerus produces many challenges with limited surgical options.
The aim of this study was to evaluate the clinical outcomes after
the use of a reverse shoulder arthroplasty under these circumstances.
Between 2007 and 2012, 19 patients (15 women and four men, mean
age 66 years; 52 to 82) with failed internal fixation after a proximal
humeral fracture, underwent implant removal and reverse shoulder arthroplasty
(RSA). The mean follow-up was 36 months (25 to 60). The mean American
Shoulder and Elbow Score improved from 27.8 to 50.1 (p = 0.019).
The mean Simple Shoulder Test score improved from 0.7 to 3.2 (p
= 0.020), and the mean visual analogue scale for pain improved from
6.8 to 4.3 (p = 0.012). Mean forward flexion improved from 58.7°
to 101.1° (p <
0.001), mean abduction from 58.7° to 89.1° (p
= 0.012), mean external rotation from 10.7° to 23.1° (p = 0.043)
and mean internal rotation from buttocks to L4 (p = 0.034). A major
complication was recorded in five patients (26%) (one intra-operative
fracture, loosening of the humeral component in two and two peri-prosthetic
fractures). A total of 15 patients (79%) rated their outcome as
excellent or good, one (5%) as satisfactory, and three (16%) as
unsatisfactory. An improvement in outcomes and pain can be expected when performing
a RSA as a salvage procedure after failed internal fixation of a
fracture of the proximal humerus. Patients should be cautioned about
the possibility for major complications following this technically
demanding procedure. Cite this article:
In this study we present our experience with
four generations of uncemented total knee arthroplasty (TKA) from Smith
&
Nephew: Tricon M, Tricon LS, Tricon II and Profix, focusing
on the failure rates correlating with each design change. Beginning
in 1984, 380 Tricon M, 435 Tricon LS, 305 Tricon 2 and 588 Profix
were implanted by the senior author. The rate of revision for loosening
was 1.1% for the Tricon M, 1.1% for the Tricon LS, 0.5% for the
Tricon 2 with a HA coated tibial component, and 1.3% for the Profix
TKA. No loosening of the femoral component was seen with the Tricon
M, Tricon LS or Tricon 2, with no loosening seen of the tibial component
with the Profix TKA. Regarding revision for wear, the incidence
was 13.1% for the Tricon M, 6.6% for the Tricon LS, 2.3% for the
Tricon 2, and 0% for the Profix. These results demonstrate that
improvements in the design of uncemented components, including increased
polyethylene thickness, improved polyethylene quality, and the introduction
of hydroxyapatite coating, has improved the outcomes of uncemented
TKA over time.
Primary total knee arthroplasty (TKA) is a reliable
procedure with reproducible long-term results. Nevertheless, there
are conditions related to the type of patient or local conditions
of the knee that can make it a difficult procedure. The most common
scenarios that make it difficult are discussed in this review. These
include patients with many previous operations and incisions, and
those with severe coronal deformities, genu recurvatum, a stiff knee,
extra-articular deformities and those who have previously undergone
osteotomy around the knee and those with chronic dislocation of
the patella. Each condition is analysed according to the characteristics of
the patient, the pre-operative planning and the reported outcomes. When approaching the difficult primary TKA surgeons should use
a systematic approach, which begins with the review of the existing
literature for each specific clinical situation. Cite this article:
A new method of vascularised tibial grafting
has been developed for the treatment of avascular necrosis (AVN)
of the talus and secondary osteoarthritis (OA) of the ankle. We
used 40 cadavers to identify the vascular anatomy of the distal
tibia in order to establish how to elevate a vascularised tibial
graft safely. Between 2008 and 2012, eight patients (three male,
five female, mean age 50 years; 26 to 68) with isolated AVN of the
talus and 12 patients (four male, eight female, mean age 58 years;
23 to 76) with secondary OA underwent vascularised bone grafting
from the distal tibia either to revascularise the talus or for arthrodesis.
The radiological and clinical outcomes were evaluated at a mean
follow-up of 31 months (24 to 62). The peri-malleolar arterial arch
was confirmed in the cadaveric study. A vascularised bone graft
could be elevated safely using the peri-malleolar pedicle. The clinical
outcomes for the group with AVN of the talus assessed with the mean
Mazur ankle grading scores, improved significantly from 39 points
(21 to 48) pre-operatively to 81 points (73 to 90) at the final
follow-up (p = 0.01). In all eight revascularisations, bone healing
was obtained without progression to talar collapse, and union was
established in 11 of 12 vascularised arthrodeses at a mean follow-up
of 34 months (24 to 58). MRI showed revascularisation of the talus
in all patients. We conclude that a vascularised tibial graft can be used both
for revascularisation of the talus and for the arthrodesis of the
ankle in patients with OA secondary to AVN of the talus. Cite this article:
Drug therapy forms an integral part of the management
of many orthopaedic conditions. However, many medicines can produce
serious adverse reactions if prescribed inappropriately, either
alone or in combination with other drugs. Often these hazards are
not appreciated. In response to this, the European Union recently
issued legislation regarding safety measures which member states
must adopt to minimise the risk of errors of medication. In March 2014 the Medicines and Healthcare products Regulatory
Agency and NHS England released a Patient Safety Alert initiative
focussed on errors of medication. There have been similar initiatives
in the United States under the auspices of The National Coordinating
Council for Medication Error and The Joint Commission on the Accreditation
of Healthcare Organizations. These initiatives have highlighted
the importance of informing and educating clinicians. Here, we discuss common drug interactions and contra-indications
in orthopaedic practice. This is germane to safe and effective clinical
care. Cite this article:
Fresh-frozen allograft bone is frequently used
in orthopaedic surgery. We investigated the incidence of allograft-related
infection and analysed the outcomes of recipients of bacterial culture-positive
allografts from our single-institute bone bank during bone transplantation.
The fresh-frozen allografts were harvested in a strict sterile environment
during total joint arthroplasty surgery and immediately stored in
a freezer at -78º to -68º C after packing. Between January 2007
and December 2012, 2024 patients received 2083 allografts with a
minimum of 12 months of follow-up. The overall allograft-associated
infection rate was 1.2% (24/2024). Swab cultures of 2083 allografts
taken before implantation revealed 21 (1.0%) positive findings.
The 21 recipients were given various antibiotics at the individual
orthopaedic surgeon’s discretion. At the latest follow-up, none
of these 21 recipients displayed clinical signs of infection following
treatment. Based on these findings, we conclude that an incidental positive
culture finding for allografts does not correlate with subsequent
surgical site infection. Additional prolonged post-operative antibiotic
therapy may not be necessary for recipients of fresh-frozen bone
allograft with positive culture findings. Cite this article:
We analysed the long-term clinical and radiological results of 63 uncemented Low Contact Stress total knee replacements in 47 patients with rheumatoid arthritis. At a mean follow-up of 12.9 years (10 to 16), 36 patients (49 knees) were still alive; three patients (five knees) were lost to follow-up. Revision was necessary in three knees (4.8%) and the rate of infection was 3.2%. The mean clinical and functional Knee Society scores were 90 (30 to 98) and 59 (25 to 90), respectively, at final follow-up and the mean active range of movement was 104° (55° to 120°). The survival rate was 94% at 16 years but 85.5% of patients lost to follow-up were considered as failures. Radiological evidence of impending failure was noted in one knee.
The Unified Classification System (UCS) was introduced
because of a growing need to have a standardised universal classification
system of periprosthetic fractures. It combines and simplifies many
existing classification systems, and can be applied to any fracture
around any partial or total joint replacement occurring during or
after operation. Our goal was to assess the inter- and intra-observer
reliability of the UCS in association with knee replacement when
classifying fractures affecting one or more of the femur, tibia
or patella. We used an international panel of ten orthopaedic surgeons with
subspecialty fellowship training and expertise in adult hip and
knee reconstruction (‘experts’) and ten residents of orthopaedic
surgery in the last two years of training (‘pre-experts’). They
each received 15 radiographs for evaluation. After six weeks they
evaluated the same radiographs again but in a different order. The reliability was assessed using the Kappa and weighted Kappa
values. The Kappa values for inter-observer reliability for the experts
and the pre-experts were 0.741 (95% confidence interval (CI) 0.707
to 0.774) and 0.765 (95% CI 0.733 to 0.797), respectively. The weighted
Kappa values for intra-observer reliability for the experts and
pre-experts were 0.898 (95% CI 0.846 to 0.950) and 0.878 (95% CI
0.815 to 0.942) respectively. The UCS has substantial inter-observer reliability and ‘near
perfect’ intra-observer reliability when used for periprosthetic
fractures in association with knee replacement in the hands of experienced
and inexperienced users. Cite this article:
The use of robots in orthopaedic surgery is an
emerging field that is gaining momentum. It has the potential for significant
improvements in surgical planning, accuracy of component implantation
and patient safety. Advocates of robot-assisted systems describe
better patient outcomes through improved pre-operative planning
and enhanced execution of surgery. However, costs, limited availability,
a lack of evidence regarding the efficiency and safety of such systems
and an absence of long-term high-impact studies have restricted
the widespread implementation of these systems. We have reviewed
the literature on the efficacy, safety and current understanding of
the use of robotics in orthopaedics. Cite this article: