Advertisement for orthosearch.org.uk
Results 161 - 180 of 2239
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 5 | Pages 902 - 906
1 Sep 1999
Ochi M Iwasa J Uchio Y Adachi N Sumen Y

We examined whether somatosensory evoked potentials (SEPs) were detectable after direct electrical stimulation of injured, reconstructed and normal anterior cruciate ligaments (ACL) during arthroscopy under general anaesthesia. We investigated the position sense of the knee before and after reconstruction and the correlation between the SEP and instability. We found detectable SEPs in all ligaments which had been reconstructed with autogenous semitendinosus and gracilis tendons over the past 18 months as well as in all cases of the normal group. The SEP was detectable in only 15 out of 32 cases in the injured group, although the voltages in the injured group were significantly lower than those of the controls. This was not the case in the reconstructed group. The postoperative position sense in 17 knees improved significantly, but there was no correlation between it and the voltage. The voltage of stable knees was significantly higher than that of the unstable joints. Our findings showed that sensory reinnervation occurred in the reconstructed human ACL and was closely related to the function of the knee


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 6 | Pages 845 - 851
1 Aug 2003
Liow RYL McNicholas MJ Keating JF Nutton RW

We treated 21 patients with 22 dislocations of the knee by repair or reconstruction of all injured ligaments. Eight knees were treated in the acute phase (less than two weeks after injury); the remainder were treated more than six months after injury (6 to 72). Reconstructions were carried out with a combination of autograft and allograft tendons and by direct ligament repair where possible. At a mean follow-up of 32 months (11 to 77) the mean Lysholm score was 87 (81 to 91) in the acute group and 75 (53 to 100) in the delayed group. The mean Tegner activity rating was 5 in the acute group and 4.4 in the delayed group. The International Knee Documentation Committee assessment revealed no differences between the two groups. Instrumented testing of knee stability indicated better results for anterior cruciate ligament reconstructions which had been undertaken in the acute phase, but no difference in the outcome of posterior cruciate ligament reconstructions. There was no difference in the loss of knee movement between the two groups. Although the differences were small, the outcome in terms of overall knee function, activity levels and anterior tibial translation were better in those knees which had been reconstructed within two weeks of injury


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 4 | Pages 558 - 560
1 May 2000
Mayr JM Pierer GR Linhart WE

We describe the reconstruction of a defect of the medial malleolus which was the result of an accident in a ten-year-old child. A graft from the iliac crest, with the apophyseal cartilage and perichondrium, was used for reconstruction of the medial malleolus, the growth plate and the adjacent metaphyseal defect, respectively. The soft-tissue defect was covered with a free scapular flap with microvascular anastomosis. Three years after the injury stability of the ankle is excellent with adequate growth of the reconstructed epiphyseal plate


Bone & Joint Research
Vol. 6, Issue 11 | Pages 621 - 622
1 Nov 2017
Queen RM


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 4 | Pages 551 - 554
1 Jul 1994
Tsujino A Itoh Y Hayashi K

We report the reconstruction of two cases of floating thumb by transplanting the distal two-thirds of the fourth metatarsal. Opponensplasty was performed after six months and resulted in satisfactory morphological and functional results. The metatarsal defect was filled by a full-thickness iliac bone graft including the apophysis. This prevented shortening of the fourth toe and formed a new metatarsophalangeal joint


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 6 | Pages 914 - 919
1 Nov 1995
Hertel R Pisan M Jakob R

Between 1989 and 1994 we used a vascularised ipsilateral fibular graft in 24 patients with segmental tibial defects. We report 12 patients with a minimum follow-up of two years. The graft was either transposed medially or inverted on its vascular pedicle. Full weight-bearing was achieved at between four and seven months. We had few complications and consider that the use of this method is a valuable option in reconstruction of the tibia


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 4 | Pages 709 - 713
1 Jul 1990
Marti R Raaymakers E Nolte P

We have analysed 31 malunited ankle fractures treated by reconstructive osteotomies. In all cases the malunited fibula has been corrected; this has been combined with other osteotomies and with fixation of ununited fragments as indicated. Our results show that, unless function was severely impaired, reconstruction was always worth while, no matter how long ago the injury had occurred and even if there were already arthritic changes


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 5 | Pages 773 - 779
1 Sep 1997
Abudu A Grimer RJ Cannon SR Carter SR Sneath RS

We treated 35 patients with primary malignant tumours of the periacetabular area by resection and prosthetic reconstruction of the defect. At a mean follow-up of 84 months, 15 patients (43%) were free from disease. The most common complications were deep infection (26%), local recurrence (24%) and recurrent dislocation of the hip (17%). The surviving patients achieved an average of 70% of their premorbid function. This method of reconstruction has a high morbidity and should be performed only at specialist centres, but the functional and oncological outcomes are satisfactory


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 5 | Pages 802 - 805
1 Sep 1991
Horibe S Shino K Taga I Inoue M Ono K

Fresh frozen allogeneic tendon was used to reconstruct the lateral ligaments in 17 ankles. Two or more years later, 13 returned for follow-up examination. The mean age at operation was 23 years (range 15 to 39); the interval between injury and operation varied from six months to 20 years. There were no infections and no immunological rejections, and according to Sefton's criteria, nine patients were excellent and four good. No patient complained of instability of the ankle and stress radiography confirmed this improvement. Allograft reconstruction of the lateral ligaments of the ankle is a new method of treatment which restores stability without sacrificing normal tendons


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 6 | Pages 834 - 837
1 Aug 2001
Natsu-ume T Shino K Nakata K Nakamura N Toritsuka Y Mae T

A total of 30 patients who underwent endoscopic reconstruction of the anterior cruciate ligament using quadrupled hamstring tendons, through a single drill hole in the femur, had MRI 24 to 28 months after operation. In 18 patients the scans revealed that both the anterior and posterior portions of the graft ran in parallel from the inside of the femoral to the tibial tunnel. In 12, the posterior bundle had moved anteriorly and the anterior bundle could not be identified at the anterodistal border of the femoral tunnel. The mean difference in the anterior laxity, when compared with the contralateral knee, was 2.0 ± 1.7 mm and 4.3 ± 2.8 mm for the two types, respectively. Damage to the anterior bundle may occur when using the endoscopic technique because of biomechanical disadvantages, including concentration of loading and repetitive bending stress in the anterior bundle at the opening of the femoral tunnel


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 2 | Pages 200 - 203
1 Mar 1994
Fujikawa K Ohtani T Matsumoto H Seedhom B

We describe a new method for the reconstruction of ruptures of the patellar ligament or the quadriceps tendon, using the flexible open-weave polyester Leeds-Keio prosthetic ligament. Of 25 operations performed since 1985, we were able to review 18 patients (19 knees) with a mean follow-up of 3.5 years (3 to 6.5). No patient had required immobilisation of the knee after operation and the average period to return to normal activities without a walking aid was 10.5 weeks. The average range of motion was 146 degrees, and four patients could squat fully in the Japanese style. There was an extension lag (< 10 degrees) in only four patients; eight patients had some patellar crepitus which was mildly painful in three. There were no cases of infection, persistent joint effusion or rerupture of the extensor apparatus


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 3 | Pages 356 - 360
1 Apr 2002
Nau T Lavoie P Duval N

We have undertaken a randomized clinical trial comparing two methods of reconstruction of the anterior cruciate ligament in patients with chronic instability. We used an ipsilateral bone-patellar-tendon-bone autograft in 27 patients and the Ligament Advancement Reinforcement System (LARS) artificial ligament in 26. Assessment before and at two, six, 12 and 24 months after surgery, included the history, physical examination, a modified International Knee Documentation Committee (IKDC) score, the Tegner score, the Knee Injury and Osteoarthritis Outcome Score (KOOS) and instrumented laxity testing. There were no cases of reactive synovitis or of infection of the knee, and there was no difference regarding the failure rate between the two groups. The IKDC showed no significant differences between the two groups at any stage of the follow-up. The KOOS evaluation showed consistently better results in all subscales for the LARS group during the first year of follow-up. After 24 months these differences were no longer evident. Instrument-tested laxity was greater in the LARS group at all stages of follow-up, but the differences were not significant at 24 months. Our findings suggest that at follow-up at 24 months the LARS ligament seems to be a satisfactory treatment option, especially when an early return to high levels of activity is demanded


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 5 | Pages 815 - 817
1 Nov 1988
Kumar V Satku K Helm R Pho R

Seven patients with segmental defects of both bones of the forearm had reconstruction operations using a vascularised fibular graft to bridge the radius. Reasonable forearm rotation was preserved with full elbow movements and satisfactory hand function


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 4 | Pages 535 - 541
1 Apr 2008
Pendegrass CJ Sundar S Oddy MJ Cannon SR Briggs T Blunn GW

We used an in vivo model to assess the use of an autogenous cancellous bone block and marrow graft for augmenting tendon reattachment to metallic implants. We hypothesised that augmentation of the tendon-implant interface with a bone block would enable retention of the graft on the implant surface, enhance biological integration, and result in more consistent functional outcomes compared with previously reported morcellised graft augmentation techniques. A significant improvement in functional weight-bearing was observed between six and 12 weeks. The significant increase in ground reaction force through the operated limb between six and 12 weeks was greater than that reported previously with morcellised graft augmented reconstructions. Histological appearance and collagen fibre orientation with bone block augmentation more closely resembled that of an intact enthesis compared with the morcellised grafting technique. Bone block augmentation of tendon-implant interfaces results in more reliable functional and histological outcomes, with a return to pre-operative levels of weight-bearing by 24 weeks


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 7 | Pages 1004 - 1008
1 Sep 2002
Rödl RW Gosheger G Gebert C Lindner N Ozaki T Winkelmann W

In 45 patients we assessed the functional results and complications for three different reconstructive procedures after resection of primary tumors of the proximal humerus. An osteoarticular allograft was used in 11, a clavicula pro humero operation in 15 and a tumour prosthesis in 19. The glenoid was resected with the proximal humerus in 25 patients. The axillary nerve was resected in 42 patients. The complication rate was lowest after reconstruction with a tumour prosthesis. The clavicula pro humero operation resulted in the most revisions. Cumulative survival rates for all the reconstructive procedures were similar. At follow-up at two years the functional results for the three reconstructive procedures were the same with a mean functional rating of 79% (Musculoskeletal Tumor Society). Excision of the glenoid had no influence on the functional result. Our findings indicate that the use of a tumour prosthesis is the most reliable limb-salvage procedure for the proximal humerus. The clavicula pro humero is an appropriate procedure if a prosthesis cannot be used


The Bone & Joint Journal
Vol. 100-B, Issue 10 | Pages 1359 - 1363
1 Oct 2018
Chiu Y Chung T Wu C Tsai K Jou I Tu Y Ma C

Aims

This study reports the outcomes of a technique of soft-tissue coverage and Chopart amputation for severe crush injuries of the forefoot.

Patients and Methods

Between January 2012 to December 2016, 12 patients (nine male; three female, mean age 38.58 years; 26 to 55) with severe foot crush injury underwent treatment in our institute. All patients were followed-up for at least one year. Their medical records, imaging, visual analogue scale score, walking ability, complications, and functional outcomes one year postoperatively based on the American Orthopedic Foot and Ankle Society (AOFAS) and 36-Item Short-Form Health Survey (SF-36) scores were reviewed.


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 2 | Pages 282 - 287
1 Mar 2003
Kimura A Aoki M Fukushima S Ishii S Yamakoshi K

We reconstructed defects in the infraspinatus tendon using polytetrafluoroethylene (PTFE) felt grafts in 31 beagle dogs and examined the mechanical responses and histocompatibility. Except for one infected specimen, all the reconstructed infraspinatus tendons healed. We examined eight specimens each immediately after surgery and at six and 12 weeks. The ultimate tensile strength of the reconstructed tendons was 60.84 N, 172.88 N, and 306.51 N immediately after surgery and at six and 12 weeks, respectively. The stiffness of the specimens at the PTFE felt-bone interface was 9.61 kN/m, 64.67 kN/m, and 135.09 kN/m immediately after surgery and at six and 12 weeks, respectively. Six tendons were examined histologically at three, six, 12 and 24 weeks. Histological analysis showed that there was ingrowth of fibrous tissue between the PTFE fibres. Foreign-body reactions were found at the margin of the PTFE-bone interface between 12 and 24 weeks. The mechanical recovery and tissue affinity of PTFE felt to bone and to tendon support its use for reconstruction of the rotator cuff. The possible development of a foreign-body reaction should be borne in mind


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 1 | Pages 100 - 105
1 Jan 1998
McKee MD Jupiter JB Bosse G Goodman L

We performed ulnar nerve neurolysis and transposition during reconstructive operations on 20 consecutive patients (21 elbows) with neuropathy after the failure of primary treatment of elbow fractures. There were 11 men and nine women with a mean age of 48.3 years. Preoperatively, four elbows were in McGowan stage I, seven in stage II and ten in stage III and the mean Gabel and Amadio ulnar nerve score was 3.2. At a mean follow-up of 32.1 months (24 to 67) we performed comprehensive neurological, functional, electrophysiological and outcome assessments. Patient satisfaction was high with good pain relief and restoration of hand strength and dexterity. The mean Gabel and Amadio score had improved to 6.5, an improvement of 3.3. There were one excellent, 16 good, 2 fair and 2 poor results; both of the last were due to failure of the underlying elbow reconstruction. Even for advanced stage-II and stage-III lesions we achieved good function, return of intrinsic power, and a high rate of patient satisfaction


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 1 | Pages 21 - 30
1 Jan 2003
Mears DC Velyvis J Resident

We have retrospectively reviewed the clinical and radiological results in 204 consecutive adult patients who had surgical correction of 70 late post-traumatic pelvic nonunions and 134 malalignments. The deformed pelvises were subdivided into united (true), unstable, ununited, and partially stable malalignments with heterotopic bone. The principal complaints were of pain, pelvic instability, sitting imbalance, and apparent limb-length discrepancy. After surgery, 195 patients (96%) achieved a primary union and 144 (71%) had slight, intermittent or no pelvic pain, while pelvic instability was entirely eliminated. Overall, 131 patients (64.2%) were extremely satisfied, 58 (28.4%) were satisfied and 15 (7.4%) were unsatisfied. After reconstruction of the malaligned pelvises, 67 results (50%) were anatomical, 47 (35%) were satisfactory and 20 (15%) were unsatisfactory. For a pelvic nonunion with local osteopenia and malalignment, stabilisation of all three pelvic columns is recommended. True pelvic (united) malunions were the most satisfactorily realigned and had the fewest complications. Ununited and unstable malalignments, especially those with heterotopic bone, had the poorest corrections and the most neurological complications. A therapeutic alternative, by the local resection of a symptomatic bony prominence, and fixation in situ of a posterior pelvic nonunion, gives highly effective symptomatic relief with fewer complications. Despite this, many patients had persistent low back pain


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 6 | Pages 1045 - 1050
1 Nov 1998
Donati D Biscaglia R

We have studied 35 patients with infected reconstructions after segmental resection for bone tumours. Two different regimes of treatment were employed both of which entailed debridement and the use of cement impregnated with antibiotic. In 25 patients gentamicin-PMMA beads were used and in ten an antibiotic-impregnated cement spacer. Better results were achieved with the second procedure in terms of cases healed, the number of operations, time of healing, time of recovery and the functional score. The use of vancomycin in the cement spacer gave better local control