Advertisement for orthosearch.org.uk
Results 161 - 180 of 3310
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 65-B, Issue 2 | Pages 160 - 162
1 Mar 1983
Grace D

Three cases of a rare complication of Salter Type II fracture-separations of the distal tibial epiphysis are described. Interposition of the anterior tibial neurovascular bundle between the displaced epiphysis and the lower tibia prevented reduction and, in two patients, the blood supply to the foot was compromised. Open reduction and internal fixation resulted in a satisfactory outcome in each case


The Journal of Bone & Joint Surgery British Volume
Vol. 62-B, Issue 2 | Pages 188 - 191
1 May 1980
Glynn M Dunlop J Fitzpatrick D

Seventy-two Mitchell distal metatarsal osteotomies for hallux valgus performed over a period of 10 years have been reviewed. Sixty-six (92 per cent) were graded as excellent or good. Retrospective radiographic analysis of 29 of these cases showed that the operation had reduced the intermetatarsal angles to within normal anatomical limits. No patient experienced a worsening of symptoms as a result of the operation


The Journal of Bone & Joint Surgery British Volume
Vol. 55-B, Issue 1 | Pages 96 - 105
1 Feb 1973
Rana NA Taylor AR

1. The results of excision of the distal end of the ulna in eighty-six wrists of seventy patients suffering from rheumatoid arthritis are presented. 2. There was relief of pain in 93 per cent and restoration of full rotation in 87 per cent. 3. Further destructive changes of the radio-carpal joint were seen in 85 per cent, but these did not affect the good clinical results


The aims of this study were to assess the efficacy of a newly designed radiological technique (the radial groove view) for the detection of protrusion of screws in the groove for the extensor pollicis longus tendon (EPL) during plating of distal radial fractures. We also aimed to determine the optimum position of the forearm to obtain this view. We initially analysed the anatomy of the EPL groove by performing three-dimensional CT on 51 normal forearms. The mean horizontal angle of the groove was 17.8° (14° to 23°). We found that the ideal position of the fluoroscopic beam to obtain this view was 20° in the horizontal plane and 5° in the sagittal plane. We then intra-operatively assessed the use of the radial groove view for detecting protrusion of screws in the EPL groove in 93 fractures that were treated by volar plating. A total of 13 protruding screws were detected. They were changed to shorter screws and these patients underwent CT scans of the wrist immediately post-operatively. There remained one screw that was protruding. These findings suggest that the use of the radial groove view intra-operatively is a good method of assessing the possible protrusion of screws into the groove of EPL when plating a fracture of the distal radius. Cite this article: Bone Joint J 2013;95-B:1372–6


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 5 | Pages 797 - 801
1 Sep 1995
Choi K Chan W Lam T Cheng J

Distal radial fractures are common in children. Recent outcome studies have cast doubt on the success of treatment by closed reduction and application of plaster. The most important risk factor for poor outcome is translation of the fracture. If a distal radial fracture is displaced by more than half the diameter of the bone at the fracture site it should be classified as high risk. We performed percutaneous Kirschner-wire pinning on 157 such high-risk distal radial fractures in children under 16 years of age. The predicted early and late failure rate was reduced from 60% to 14% and only 1.5% of patients had significant limitation of forearm movement of more than 15 degrees in the final assessment at a mean of 31 months after operation. There were no cases of early physeal closure or deep infection


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 7 | Pages 974 - 978
1 Sep 2001
Gambirasio R Riand N Stern R Hoffmeyer P

The treatment of multifragmentary, intra-articular fractures of the distal humerus is difficult, even in young patients with bone of good quality, but is worse in elderly patients who have varying degrees of osteopenia. We have evaluated the functional outcome of primary total elbow replacement (TER) in the treatment of these fractures in ten elderly patients followed for a minimum of one year. There were no complications in regard to the soft tissues, bone or prosthesis. The mean range of flexion obtained was 125° (110 to 140) and loss of extension was 23.5° (0 to 50). The mean Mayo score was 94 points (80 to 100) and patient satisfaction was high. We feel that TER provides an alternative to open reduction and internal fixation in the management of these complicated fractures in the elderly


The Bone & Joint Journal
Vol. 96-B, Issue 4 | Pages 548 - 554
1 Apr 2014
Sun H Luo CF Zhong B Shi HP Zhang CQ Zeng BF

Our aim was to compare polylevolactic acid screws with titanium screws when used for fixation of the distal tibiofibular syndesmosis at mid-term follow-up. A total of 168 patients, with a mean age of 38.5 years (18 to 72) who were randomly allocated to receive either polylevolactic acid (n = 86) or metallic (n = 82) screws were included. The Baird scoring system was used to assess the overall satisfaction and functional recovery post-operatively. The demographic details and characteristics of the injury were similar in the two groups. The mean follow-up was 55.8 months (48 to 66). The Baird scores were similar in the two groups at the final follow-up. Patients in the polylevolactic acid group had a greater mean dorsiflexion (p = 0.011) and plantar-flexion of the injured ankles (p < 0.001). In the same group, 18 patients had a mild and eight patients had a moderate foreign body reaction. In the metallic groups eight had mild and none had a moderate foreign body reaction (p <  0.001). In total, three patients in the polylevolactic acid group and none in the metallic group had heterotopic ossification (p = 0.246). We conclude that both screws provide adequate fixation and functional recovery, but polylevolactic acid screws are associated with a higher incidence of foreign body reactions. Cite this article: Bone Joint J 2014;96-B:548–54


The Bone & Joint Journal
Vol. 98-B, Issue 1 | Pages 131 - 136
1 Jan 2016
Kurien T Price KR Pearson RG Dieppe C Hunter JB

A retrospective study was performed in 100 children aged between two and 16 years, with a dorsally angulated stable fracture of the distal radius or forearm, who were treated with manipulation in the emergency department (ED) using intranasal diamorphine and 50% oxygen and nitrous oxide. Pre- and post-manipulation radiographs, the final radiographs and the clinical notes were reviewed. A successful reduction was achieved in 90 fractures (90%) and only three children (3%) required remanipulation and Kirschner wire fixation or internal fixation. The use of Entonox and intranasal diamorphine is safe and effective for the closed reduction of a stable paediatric fracture of the distal radius and forearm in the ED. . By facilitating discharge on the same day, there is a substantial cost benefit to families and the NHS and we recommend this method. Take home message: Simple easily reducible fractures of the distal radius and forearm in children can be successfully and safely treated in the ED using this approach, thus avoiding theatre admission and costly hospital stay. . Cite this article: Bone Joint J 2016;97-B:131–6


The Bone & Joint Journal
Vol. 95-B, Issue 11 | Pages 1544 - 1550
1 Nov 2013
Uchiyama S Itsubo T Nakamura K Fujinaga Y Sato N Imaeda T Kadoya M Kato H

This multicentre prospective clinical trial aimed to determine whether early administration of alendronate (ALN) delays fracture healing after surgical treatment of fractures of the distal radius. The study population comprised 80 patients (four men and 76 women) with a mean age of 70 years (52 to 86) with acute fragility fractures of the distal radius requiring open reduction and internal fixation with a volar locking plate and screws. Two groups of 40 patients each were randomly allocated either to receive once weekly oral ALN administration (35 mg) within a few days after surgery and continued for six months, or oral ALN administration delayed until four months after surgery. Postero-anterior and lateral radiographs of the affected wrist were taken monthly for six months after surgery. No differences between groups was observed with regard to gender (p = 1.0), age (p = 0.916), fracture classification (p = 0.274) or bone mineral density measured at the spine (p = 0.714). The radiographs were assessed by three independent assessors. There were no significant differences in the mean time to complete cortical bridging observed between the ALN group (3.5 months (. se. 0.16)) and the no-ALN group (3.1 months (. se. 0.15)) (p = 0.068). All the fractures healed in the both groups by the last follow-up. Improvement of the Quick-Disabilities of the Arm, Shoulder and Hand (QuickDASH) score, grip strength, wrist range of movement, and tenderness over the fracture site did not differ between the groups over the six-month period. Based on our results, early administration of ALN after surgery for distal radius fracture did not appear to delay fracture healing times either radiologically or clinically. Cite this article: Bone Joint J 2013;95-B:1544–50


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 5 | Pages 663 - 667
1 Jul 2001
Arazi M Memik R Ögün TC Yel M

Our aim was to determine the clinical effectiveness and safety of Ilizarov external fixation for the acute treatment of severely comminuted extra-articular and intercondylar fractures of the distal femur. A total of 14 consecutive patients with complex fractures was treated. There were three type-A3, two type-C2 and nine type-C3 fractures according to the AO/ASIF system. The mean follow-up was 14 months. Most fractures (13) united primarily at a mean of 16 weeks. One patient with a type-IIIA open fracture had infection and nonunion. The mean range of flexion of the knee at the final follow-up was 105° (35 to 130). We conclude that, in the treatment of comminuted fractures of the distal femur, the Ilizarov fixator is safe and effective in providing stability and allowing early rehabilitation


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 2 | Pages 291 - 294
1 Mar 1991
Ballmer F Gerber C

Five consecutive unstable fractures of the distal third of the clavicle were treated by indirect open reduction and internal fixation using a temporary Bosworth-type screw. Coracoclavicular fixation provided and maintained reduction of the fracture. Healing occurred uneventfully within nine weeks in all cases. The screw was removed under local anaesthesia after healing of the fracture and there were no surgical complications. Shoulder function was restored to the pre-injury level. Temporary coracoclavicular screw fixation appears to be a valuable alternative for the treatment of type II fractures of the distal third of the clavicle


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 4 | Pages 552 - 556
1 Apr 2009
Hannouche D Ballis R Raould A Nizard RS Masquelet AC

We describe a lateral approach to the distal humerus based on initial location of the superficial branches of the radial nerve, the inferior lateral cutaneous nerve of the arm and the posterior cutaneous nerve of the forearm. In 18 upper limbs the superficial branches of the radial nerve were located in the subcutaneous tissue between the triceps and brachioradialis muscles and dissected proximally to their origin from the radial nerve, exposing the shaft of the humerus. The inferior lateral cutaneous nerve of the arm arose from the radial nerve at the lower part of the spiral groove, at a mean of 14.2 cm proximal to the lateral epicondyle. The posterior cutaneous nerve of the forearm arose from the inferior lateral cutaneous nerve at a mean of 6.9 cm (6.0 to 8.1) proximal to the lateral epicondyle and descended vertically along the dorsal aspect of the forearm. The size and constant site of emergence between the triceps and brachioradialis muscles constitute a readily identifiable landmark to explore the radial nerve and expose the humeral shaft


Bone & Joint Research
Vol. 1, Issue 6 | Pages 111 - 117
1 Jun 2012
von Recum J Matschke S Jupiter JB Ring D Souer J Huber M Audigé L

Objectives. To investigate the differences of open reduction and internal fixation (ORIF) of complex AO Type C distal radius fractures between two different models of a single implant type. Methods. A total of 136 patients who received either a 2.4 mm (n = 61) or 3.5 mm (n = 75) distal radius locking compression plate (LCP DR) using a volar approach were followed over two years. The main outcome measurements included motion, grip strength, pain, and the scores of Gartland and Werley, the Short-Form 36 (SF-36) and the Disabilities of the Arm, Shoulder, and Hand (DASH). Differences between the treatment groups were evaluated using regression analysis and the likelihood ratio test with significance based on the Bonferroni corrected p-value of < 0.003. Results. The groups were similar with respect to baseline and injury characteristics as well as general surgical details. The risk of experiencing a complication after ORIF with a LCP DR 2.4 mm was 18% (n = 11) compared with 11% (n = 8) after receiving a LCP DR 3.5 mm (p = 0.45). Wrist function was also similar between the cohorts based on the mean ranges of movement (all p > 0.052) and grip strength measurements relative to the contralateral healthy side (p = 0.583). In addition, DASH and SF-36 component scores as well as pain were not significantly different between the treatment groups throughout the two-year period (all p ≥ 0.005). No patient from either treatment group had a step-off > 2 mm. Conclusions. Differences in plate design do not influence the overall final outcome of fracture fixation using LCP.


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 4 | Pages 660 - 661
1 Jul 1991
Knudsen C Grobler G Close R

We describe a simple method of inserting the distal screws in a locked femoral nail. The method requires no aiming device and no assistant. The only equipment needed is a 3 mm Kirschner wire and an air drill


The Journal of Bone & Joint Surgery British Volume
Vol. 45-B, Issue 4 | Pages 745 - 747
1 Nov 1963
Blockey NJ Lawrie JH

We describe two siblings with congenital growth defects of the distal limb bones and their progress over four years. They bear some resemblances to a boy described in 1958 by Solonen and Sulamaa and to a father and his three sons described in 1944 by Nievergelt


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 1 | Pages 110 - 114
1 Jan 1996
Butt MS Krikler SJ Ali MS

We performed a prospective, randomised controlled trial of the operative versus non-operative treatment of 42 displaced fractures of the distal femur in elderly patients. Excellent or good results were achieved in 53% of the operated group and in 31% of the non-operated group. There were more complications in the latter, and the time to discharge was considerably longer


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 3 | Pages 485 - 487
1 May 1999
Kerry RM Masri BA Beauchamp CP Duncan CP

We describe a U-shaped approach to the distal femur which, having divided the extensor mechanism and elevated the entire quadriceps muscle, gives excellent exposure and allows a number of reconstructive options. It was used in 14 patients, 13 of whom were followed up for a mean of 3.5 years (1 to 11). There was no case of flap necrosis, and complications related to the reconstruction were acceptable


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 1 | Pages 67 - 72
1 Jan 1995
Morrey B Adams R

We have reviewed 36 of 39 consecutive patients with an average age of 68 years who had semiconstrained elbow replacement for distal humeral nonunion at an average follow-up of 50.4 months (24 to 127). Of these, 31 (86%) had satisfactory results, three (8%) had fair, and two (6%) had poor results; 32 patients (88%) had moderate or severe pain before and 91% had no or only mild discomfort after the procedure. Motion had improved from a mean arc of 29 degrees to 103 degrees before operation to 16 degrees to 127 degrees after surgery. All five flail extremities were stable at last assessment. There were seven complications (18%): two patients had deep infection, two had particulate synovitis, two had ulnar neuropathy and one had worn polyethylene bushes. Five of these seven, excluding the two with transient nueropathy, required reoperation (13%). Joint replacement arthroplasty can be a safe and reliable treatment for this difficult clinical condition, seen most commonly in elderly patients. This is a significant advance, since repeated osteosynthesis has been shown to be ineffective in most patients


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 5 | Pages 834 - 836
1 Nov 1988
Carter Aldridge M

We report 21 cases of stress injury of the distal radial growth plate-occurring in gymnasts before skeletal maturity. The injury appears to be caused by inability of the growth plate to withstand rotational and compressive forces. Our observations have confirmed that the skeletal age of gymnasts is retarded, which increases the length of time during which the epiphysis is at risk of damage


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 2 | Pages 302 - 306
1 Mar 1991
Jakim I Pieterse H Sweet M

In a prospective study of 132 patients with an average age of 35 years, unstable intra-articular fractures of the distal radius were treated by external fixator. Only 15 cases required limited open reduction. Follow-up was for a mean of 42 months. There were few complications and 83% of patients had good or excellent results. There was a statistically significant correlation between the severity of the fracture and the clinical outcome, irrespective of radiological restoration. Articular and soft-tissue damage following violent compressive forces may lead to a degree of functional impairment