Advertisement for orthosearch.org.uk
Results 161 - 180 of 462
Results per page:
The Bone & Joint Journal
Vol. 102-B, Issue 10 | Pages 1271 - 1273
1 Oct 2020
Scott CEH Simpson AHRW Pankaj P


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 85 - 90
1 Jun 2020
Blevins JL Rao V Chiu Y Lyman S Westrich GH

Aims

The purpose of this investigation was to determine the relationship between height, weight, and sex with implant size in total knee arthroplasty (TKA) using a multivariate linear regression model and a Bayesian model.

Methods

A retrospective review of an institutional registry was performed of primary TKAs performed between January 2005 and December 2016. Patient demographics including patient age, sex, height, weight, and body mass index (BMI) were obtained from registry and medical record review. In total, 8,100 primary TKAs were included. The mean age was 67.3 years (SD 9.5) with a mean BMI of 30.4 kg/m2 (SD 6.3). The TKAs were randomly split into a training cohort (n = 4,022) and a testing cohort (n = 4,078). A multivariate linear regression model was created on the training cohort and then applied to the testing cohort . A Bayesian model was created based on the frequencies of implant sizes in the training cohort. The model was then applied to the testing cohort to determine the accuracy of the model at 1%, 5%, and 10% tolerance of inaccuracy.


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 3 | Pages 399 - 403
1 May 1989
Howell F Dickson R

We present a method of visualising spinal deformities in three dimensions using conventional radiographs and computer graphics. The shape of the spinal column can be determined from the anteroposterior and lateral radiographs and displayed in any projection. In patients with adolescent idiopathic scoliosis, the fundamental lesion, an abnormal lordosis, can be demonstrated without the need for additional views. The method is applicable to other spinal deformities and may help to elucidate their three-dimensional shape


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 5 | Pages 725 - 728
1 Sep 1992
Wilson L Nolan J Heywood-Waddington M

We report the clinical and operative details of seven cases of fracture of the femoral stem of the Ring TiMESH cementless hip prosthesis (two were cemented and five uncemented). Six fractures occurred in the proximal one-third of the stem and one at mid-stem. The failures are attributed mainly to two defects in stem design, the narrowness of the anteroposterior dimensions and the depth of the recess for the titanium mesh pads. Great difficulty was experienced in removing the osseo-integrated distal fragments of the broken stems


The Journal of Bone & Joint Surgery British Volume
Vol. 35-B, Issue 2 | Pages 199 - 208
1 May 1953
Adams JC

1. The unreliable results of the conventional cup arthroplasty are attributed to mechanical imperfections in the reconstructed joint. 2. If its reliability can be improved, there will remain a place for cup arthroplasty, which, in relatively young and active patients, offers advantages over prosthetic replacement arthroplasty. 3. A technique of concentric cup arthroplasty is described. The new joint is shaped with precision to exact dimensions and lined with a cup designed to ensure stability, concentric movement and a uniform clearance between the moving parts. 4. The results so far are encouraging and justify continued clinical trial


Bone & Joint Research
Vol. 9, Issue 6 | Pages 285 - 292
1 Jun 2020
Wang Z Li H Long Z Lin S Thoreson AR Moran SL Gingery A Amadio PC Steinmann SP Zhao C

Aims

Many biomechanical studies have shown that the weakest biomechanical point of a rotator cuff repair is the suture-tendon interface at the medial row. We developed a novel double rip-stop (DRS) technique to enhance the strength at the medial row for rotator cuff repair. The objective of this study was to evaluate the biomechanical properties of the DRS technique with the conventional suture-bridge (SB) technique and to evaluate the biomechanical performance of the DRS technique with medial row knots.

Methods

A total of 24 fresh-frozen porcine shoulders were used. The infraspinatus tendons were sharply dissected and randomly repaired by one of three techniques: SB repair (SB group), DRS repair (DRS group), and DRS with medial row knots repair (DRSK group). Specimens were tested to failure. In addition, 3 mm gap formation was measured and ultimate failure load, stiffness, and failure modes were recorded.


The Bone & Joint Journal
Vol. 103-B, Issue 3 | Pages 507 - 514
1 Mar 2021
Chang JS Kayani B Wallace C Haddad FS

Aims

Total knee arthroplasty (TKA) using functional alignment aims to implant the components with minimal compromise of the soft-tissue envelope by restoring the plane and obliquity of the non-arthritic joint. The objective of this study was to determine the effect of TKA with functional alignment on mediolateral soft-tissue balance as assessed using intraoperative sensor-guided technology.

Methods

This prospective study included 30 consecutive patients undergoing robotic-assisted TKA using the Stryker PS Triathlon implant with functional alignment. Intraoperative soft-tissue balance was assessed using sensor-guided technology after definitive component implantation; soft-tissue balance was defined as intercompartmental pressure difference (ICPD) of < 15 psi. Medial and lateral compartment pressures were recorded at 10°, 45°, and 90° of knee flexion. This study included 18 females (60%) and 12 males (40%) with a mean age of 65.2 years (SD 9.3). Mean preoperative hip-knee-ankle deformity was 6.3° varus (SD 2.7°).


Bone & Joint Research
Vol. 9, Issue 10 | Pages 645 - 652
5 Oct 2020
Chao C Chen Y Lin J

Aims

To determine whether half-threaded screw holes in a new titanium locking plate design can substantially decrease the notch effects of the threads and increase the plate fatigue life.

Methods

Three types (I to III) of titanium locking plates were fabricated to simulate plates used in the femur, tibia, and forearm. Two copies of each were fabricated using full- and half-threaded screw holes (called A and B, respectively). The mechanical strengths of the plates were evaluated according to the American Society for Testing and Materials (ASTM) F382-14, and the screw stability was assessed by measuring the screw removal torque and bending strength.


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 398 - 404
1 Feb 2021
Christ AB Fujiwara T Yakoub MA Healey JH

Aims

We have evaluated the survivorship, outcomes, and failures of an interlocking, reconstruction-mode stem-sideplate implant used to preserve the native hip joint and achieve proximal fixation when there is little residual femur during large endoprosthetic reconstruction of the distal femur.

Methods

A total of 14 patients underwent primary or revision reconstruction of a large femoral defect with a short remaining proximal femur using an interlocking, reconstruction-mode stem-sideplate for fixation after oncological distal femoral and diaphyseal resections. The implant was attached to a standard endoprosthetic reconstruction system. The implant was attached to a standard endoprosthetic reconstruction system. None of the femoral revisions were amenable to standard cemented or uncemented stem fixation. Patient and disease characteristics, surgical history, final ambulatory status, and Musculoskeletal Tumor Society (MSTS) score were recorded. The percentage of proximal femur remaining was calculated from follow-up radiographs.


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 5 | Pages 724 - 728
1 Nov 1986
Veldhuizen A Baas P Webb P

We have measured the increase in height and width of the vertebral bodies and expressed them as percentages of the total growth in children aged 10 to 17 years. The first group, 10 boys and 10 girls, each had a single thoracic adolescent idiopathic scoliosis while the second group, 10 girls, each had a single lumbar adolescent idiopathic scoliosis. No significant differences were found between the growth increments and spinal dimensions of the vertebral bodies involved in the scoliotic curve and those vertebrae outside the curve in the same patient. The vertebrae were more slender in girls than in boys


Bone & Joint Research
Vol. 10, Issue 2 | Pages 105 - 112
1 Feb 2021
Feng X Qi W Fang CX Lu WW Leung FKL Chen B

Aims

To draw a comparison of the pullout strengths of buttress thread, barb thread, and reverse buttress thread bone screws.

Methods

Buttress thread, barb thread, and reverse buttress thread bone screws were inserted into synthetic cancellous bone blocks. Five screw-block constructs per group were tested to failure in an axial pullout test. The pullout strengths were calculated and compared. A finite element analysis (FEA) was performed to explore the underlying failure mechanisms. FEA models of the three different screw-bone constructs were developed. A pullout force of 250 N was applied to the screw head with a fixed bone model. The compressive and tensile strain contours of the midsagittal plane of the three bone models were plotted and compared.


The Bone & Joint Journal
Vol. 103-B, Issue 3 | Pages 553 - 561
1 Mar 2021
Smolle MA Leithner A Kapper M Demmer G Trost C Bergovec M Windhager R Hobusch GM

Aims

The aims of the study were to analyze differences in surgical and oncological outcomes, as well as quality of life (QoL) and function in patients with ankle sarcomas undergoing three forms of surgical treatment, minor or major limb salvage surgery (LSS), or amputation.

Methods

A total of 69 patients with ankle sarcomas, treated between 1981 and 2017 at two tumour centres, were retrospectively reviewed (mean age at surgery: 46.3 years (SD 22.0); 31 females (45%)). Among these 69 patients 25 were analyzed prospectively (mean age at latest follow-up: 61.2 years (SD 20.7); 11 females (44%)), and assessed for mobility using the Prosthetic Limb Users Survey of Mobility (PLUS-M; for amputees only), the Toronto Extremity Salvage Score (TESS), and the University of California, Los Angeles (UCLA) Activity Score. Individual QoL was evaluated in these 25 patients using the five-level EuroQol five-dimension (EQ-5D-5L) and Fragebogen zur Lebenszufriedenheit/Questions on Life Satisfaction (FLZ).


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 4 | Pages 588 - 592
1 Jul 1996
Rikli DA Regazzoni P

Fractures of the distal end of the radius should be treated on the same principles as other fractures involving joints. Displaced articular fractures require open reduction to allow anatomical reconstruction of both the radiocarpal and the radio-ulnar joints. For extra-articular fractures with severe comminution and shortening this enables the radial length to be re-established achieving radio-ulnar congruency. Stable internal fixation can be achieved with two 2.0 AO titanium plates placed on each of the ‘lateral’ and the ‘intermediate’ columns of the wrist at an angle of 50° to 70°. This gives good stability despite the tiny dimensions of the plates, and allows early function. We report a series of 20 fractures treated by this method of internal fixation with satisfactory results in all


The Bone & Joint Journal
Vol. 102-B, Issue 11 | Pages 1446 - 1456
1 Nov 2020
Halim UA Elbayouk A Ali AM Cullen CM Javed S

Aims

Gender bias and sexual discrimination (GBSD) have been widely recognized across a range of fields and are now part of the wider social consciousness. Such conduct can occur in the medical workplace, with detrimental effects on recipients. The aim of this review was to identify the prevalence and impact of GBSD in orthopaedic surgery, and to investigate interventions countering such behaviours.

Methods

A systematic review was conducted by searching Medline, EMCARE, CINAHL, PsycINFO, and the Cochrane Library Database in April 2020, and Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines to which we adhered. Original research papers pertaining to the prevalence and impact of GBSD, or mitigating strategies, within orthopaedics were included for review.


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 2 | Pages 285 - 288
1 Mar 1997
Hernigou P Besnard P

Plain radiographs show only two dimensions of a three-dimensional object. On anteroposterior and lateral radiographs an implant may appear to be safely within the head of the femur although surface penetration has occurred. We have attempted to identify this complication in the treatment of fractures of the femoral neck and have analysed the position of a screw or pin in the femoral head and neck on the basis of orthogonal frontal and lateral radiographs. A retrospective analysis of 60 cases of osteosynthesis of fractures of the femoral neck confirmed the risk of non-recognition of articular penetration or breaking of the cortex of the neck during surgery. Unrecognised screw penetration of the hip was observed in 8% and of the posterior part of the neck in 10%. The risk differs according to the type of fracture: it is greater in the coxa valga produced by Garden-I fractures of the femoral neck


Bone & Joint Open
Vol. 2, Issue 3 | Pages 150 - 163
1 Mar 2021
Flett L Adamson J Barron E Brealey S Corbacho B Costa ML Gedney G Giotakis N Hewitt C Hugill-Jones J Hukins D Keding A McDaid C Mitchell A Northgraves M O'Carroll G Parker A Scantlebury A Stobbart L Torgerson D Turner E Welch C Sharma H

Aims

A pilon fracture is a severe ankle joint injury caused by high-energy trauma, typically affecting men of working age. Although relatively uncommon (5% to 7% of all tibial fractures), this injury causes among the worst functional and health outcomes of any skeletal injury, with a high risk of serious complications and long-term disability, and with devastating consequences on patients’ quality of life and financial prospects. Robust evidence to guide treatment is currently lacking. This study aims to evaluate the clinical and cost-effectiveness of two surgical interventions that are most commonly used to treat pilon fractures.

Methods

A randomized controlled trial (RCT) of 334 adult patients diagnosed with a closed type C pilon fracture will be conducted. Internal locking plate fixation will be compared with external frame fixation. The primary outcome and endpoint will be the Disability Rating Index (a patient self-reported assessment of physical disability) at 12 months. This will also be measured at baseline, three, six, and 24 months after randomization. Secondary outcomes include the Olerud and Molander Ankle Score (OMAS), the five-level EuroQol five-dimenison score (EQ-5D-5L), complications (including bone healing), resource use, work impact, and patient treatment preference. The acceptability of the treatments and study design to patients and health care professionals will be explored through qualitative methods.


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 5 | Pages 816 - 821
1 Sep 1990
Matsumoto H

The mechanism of the pivot shift was investigated by analysing movements under valgus torque in 29 fresh cadaveric knees. The movements were measured in three dimensions, using biplanar photography, when all the ligaments were intact, and then after the ligaments were sequentially divided. When only the anterior cruciate ligament was sectioned, the pivot shift occurred in seven out of 20 knees examined. In the other 13, though the pivot shift was not observed, an abnormal internal rotation occurred at between 10 degrees and 50 degrees of flexion. Division of the iliotibial tract in addition to division of the anterior cruciate ligament stopped the pivot shift, as the tibia remained internally rotated throughout the range of flexion. The axis of rotation of the pivot shift was located at the medial collateral ligament, which was kept tight by the applied valgus torque. The sudden movement in the pivot shift was caused by a complex interaction between the geometry of the knee and the valgus torque applied


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 890 - 898
1 Jul 2020
Cheung PWH Wong CKH Cheung JPY

Aims

The health-related quality of life (HRQoL) of paediatric patients with orthopaedic conditions and spinal deformity is important, but existing generic tools have their shortcomings. We aim to evaluate the use of Paediatric Quality of Life Inventory (PedsQL) 4.0 generic core scales in the paediatric population with specific comparisons between those with spinal and limb pathologies, and to explore the feasibility of using PedsQL for studying scoliosis patients’ HRQoL.

Methods

Paediatric patients attending a speciality outpatient clinic were recruited through consecutive sampling. Two groups of patients were included: idiopathic scoliosis, and paediatric orthopaedic upper and lower limb condition without scoliosis. Patients were asked to complete PedsQL 4.0 generic core scales, Youth version of 5-level EuroQol-5-dimension questionnaire, and Refined Scoliosis Research Society 22-item (SRS-22r) questionnaire. Statistical analyses included scores comparison between scoliosis and limb pathology patients using independent-samples t-test, and correlation tests of PedsQL and SRS-22r.


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 5 | Pages 650 - 654
1 Jul 2003
Clarke MT Lee PTH Villar RN

Metal-on-metal (MOM) is a commonly used bearing notable for its ‘suction fit’ when lubricated. In this study, we examined the capacity for MOM bearings to protect against dislocation after total hip replacement (THR). We undertook a clinical investigation to compare the rate of dislocation of MOM bearings with those of ceramic-on-polyethylene (COP) bearings and found that one MOM bearing dislocated in a series of 109 hips (0.9%) compared with nine of 145 hips (6.2%) in the COP group (p = 0.02). We also performed an in vitro investigation comparing the peak forces generated during forced separation of the two bearings of the same dimensions at velocities from 1 to 50 cm/s. This revealed that the MOM bearing generated significant resistance to separation at all velocities (maximum mean 24 N), whereas the COP did not (maximum mean 1.9 N, p < 0.001). We conclude that MOM bearings are more stable to dislocation than COP bearings as a result of the interfacial forces provided by a thin, lubricating fluid


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 5 | Pages 756 - 763
1 Nov 1989
Joseph B

Radiographs of 155 Indian children were examined to identify the acetabular changes which occur in Perthes' disease. These changes included osteoporosis of the acetabular roof, irregularity of contour, premature fusion of the triradiate cartilage, hypertrophy of articular cartilage and changes in dimensions. These changes tended to be more marked in older children and when more than half of the femoral epiphysis was involved. Comparison with 25 cases of Perthes' disease from Liverpool showed the same picture. Several of the acetabular changes noted during the active stages were also seen in a series of 24 adult hips after Perthes' disease. Radio-isotope scans of the hips of 27 children with Perthes' disease showed a consistently increased uptake in the acetabulum on the affected side, indicative of a local increase in vascularity and metabolic activity. It was possible to postulate a working model for the pathogenesis of all the acetabular changes. A number of statistical correlations suggest that most of the changes have a bearing on the final outcome