Advertisement for orthosearch.org.uk
Results 1661 - 1680 of 2677
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 8 | Pages 1128 - 1133
1 Nov 2003
Fukui N Nakagawa T Murakami S Hiraoka H Nakamura K

Axial radiographs were obtained under valgus and external rotation stress at 45° of knee flexion with and without contraction of the quadriceps muscle in order to assess the dynamics of patellar subluxation or dislocation. The radiography was performed on 82 knees in 61 patients with patellofemoral instability, and on 44 normal knees. The lateral patellofemoral angle and the congruence angle were measured and compared with the conventional Merchant views. Both parameters showed greater differences between symptomatic and normal knees on the stress radiographs obtained without quadriceps contraction. There was a major difference in the lateral patellofemoral angles between the groups, which clearly distinguished symptomatic knees from normal controls. Congruence angles on stress radiography had a significant correlation with the functional scores obtained after a period of conservative treatment and a positive correlation with the frequency of patellar subluxation. When the quadriceps contracted, two patterns of patellar shift were observed. While the patella reduced into the trochlear groove in all normal knees and about 70% of the symptomatic knees, contraction of the quadriceps caused further subluxation of the patella in the remaining symptomatic knees. All the knee joints which showed this displacement failed to respond to conservative treatment and eventually required surgical treatment. Thus, this technique of stress radiography is a simple, cost-effective and useful method of evaluating patellar instability and predicting the prognosis


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 5 | Pages 680 - 685
1 Jul 2001
Bowditch M Villar R

Early failures have seen titanium fall from favour as a material for cemented femoral stems. Between 1989 and 1994, we performed a prospective review of a consecutive series of 122 cemented total hip replacements using the Ultima straight textured titanium stem, and report the five- to ten-year clinical and radiological outcomes. There were no revisions for loosening of the femoral stem. Revision surgery was undertaken for other reasons such as dislocation, infection and loosening of the cup in 7.3%. Of those patients without revision all but two were satisfied with their hip, with 74% graded good or excellent using a modified Harris hip score. Radiological assessment revealed probable loosening in two. Although slight vertical subsidence was found in one-third of patients it had not progressed to loosening. It is not clear whether this represents debonding. Non-progressive radiolucent lines (1 to 2 mm) were present in zone 1 at the cement-prosthesis interface in 14.7%. Calcar resorption and hypertrophy around the distal stem were not often seen. With 97% survival at a mean of 7.5 years, the medium-term results of this specific cemented titanium stem are reassuring so far, but we are concerned about debonding and future failure


The Bone & Joint Journal
Vol. 99-B, Issue 9 | Pages 1125 - 1131
1 Sep 2017
Rickman M Varghese VD

In the time since Letournel popularised the surgical treatment of acetabular fractures, more than 25 years ago, there have been many changes within the field, related to patients, surgical technique, implants and post-operative care. However, the long-term outcomes appear largely unchanged. Does this represent stasis or have the advances been mitigated by other negative factors? In this article we have attempted to document the recent changes within the surgery of patients with a fracture involving the acetabulum, outline contemporary management, and identify the major problem areas where further research is most needed.

Cite this article: Bone Joint J 2017;99-B:1125–31


The Bone & Joint Journal
Vol. 99-B, Issue 6 | Pages 749 - 758
1 Jun 2017
García-Rey E Cruz-Pardos A García-Cimbrelo E

Aims

To determine the effect of a change in design of a cementless ceramic acetabular component in fixation and clinical outcome after total hip arthroplasty

Patients and Methods

We compared 342 hips (302 patients) operated between 1999 and 2005 with a relatively smooth hydroxyapatite coated acetabular component (group 1), and 337 hips (310 patients) operated between 2006 and 2011 using a similar acetabular component with a macrotexture on the entire outer surface of the component (group 2). The mean age of the patients was 53.5 (14 to 70) in group 1 and 53.0 (15 to 70) in group 2. The mean follow-up was 12.7 years (10 to 17) for group 1 and 7.2 years (4 to 10) for group 2.


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 3 | Pages 354 - 357
1 Apr 2003
Potter D Claydon P Stanley D

Between 1993 and 1996, we undertook 35 Kudo 5 total elbow replacements in a consecutive series of 31 rheumatoid patients. A total of 25 patients (29 procedures) was evaluated at a mean follow-up of six years (5 to 7.5) using the Mayo Clinic performance index. In addition, all patients were assessed for loosening using standard anteroposterior and lateral radiographs. At review, 19 elbows (65%) had either no pain or mild pain, ten (35%) had moderate pain and none had severe pain. The mean arc of flexion/extension was 94° (35 to 130) and supination/pronation was 128° (30 to 165). A fracture of the medial epicondyle occurred during surgery in one patient. This was successfully treated with a single AO screw and a standard Kudo 5 implant was inserted. Postoperatively, there were no infections. One patient had a dislocation which was treated by closed reduction and five had neurapraxia of the ulnar nerve. Radiologically, there was no evidence of loosening of the humeral component, but two ulnar components had progressive radiolucent lines suggestive of loosening. Two other ulnar components had incomplete and non-progressive radiolucent lines. With definite radiological loosening as the endpoint, the probability of survival of the Kudo 5 prosthesis at five years using the Kaplan-Meier method was 89%


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 1 | Pages 24 - 29
1 Jan 1989
Masada K Tsuyuguchi Y Kawai H Kawabata H Noguchi K Ono K

We reviewed 36 cases of forearm deformity caused by multiple osteochondromas in 30 patients and classified them into three types: Type I showed a combination of ulnar shortening and bowing of the radius secondary to osteochondromas of the distal ulna (22 forearms). Type II showed dislocation of the radial head, either with osteochondromas of the proximal radius (Type IIa, two forearms) or secondary to more distal involvement (Type IIb, five forearms). Type III had relative radial shortening due to osteochrondromas at the distal radius (seven forearms). Operations were performed on 16 forearms in 13 patients, with 92% of satisfactory results. For Type I deformity, excision of osteochondromas, immediate ulnar lengthening and corrective osteotomy of the radius are recommended. For Type IIa, excision of the radial head is necessary, and for Type IIb, we advise gradual lengthening of the ulna using an external fixator. Excision of osteochondromas alone gave good results in Type III deformity. Our classification gives a reliable indication of the prognosis and is a guide to the choice of surgical treatment


Bone & Joint 360
Vol. 6, Issue 4 | Pages 25 - 29
1 Aug 2017


The Bone & Joint Journal
Vol. 99-B, Issue 11 | Pages 1450 - 1457
1 Nov 2017
vanWinterswijk PJTS Whitehouse SL Timperley AJ Hubble MJW Howell JR Wilson MJ

Aims

We report the incidence of radiolucent lines (RLLs) using two flanged acetabular components at total hip arthroplasty (THA) and the effect of the Rim Cutter.

Patients and Methods

We performed a retrospective review of 300 hips in 292 patients who underwent primary cemented THA. A contemporary flanged acetabular component was used with (group 1) and without (group 2) the use of the Rim Cutter and the Rimfit acetabular component was used with the Rim Cutter (group 3). RLLs and clinical outcomes were evaluated immediately post-operatively and at five years post-operatively.


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 3 | Pages 427 - 430
1 May 1986
Pool R Foster B Paterson D

Avascular necrosis is an iatrogenic complication of the treatment of congenital dislocation of the hip. In order to assess the incidence of this and other complications, we have reviewed a consecutive series of 211 children treated at some stage with the modified Denis Browne splint used in Adelaide. In 173 children treated with this splint alone for 238 subluxed or dislocated hips which were stable when reduced, six hips (2.5%) developed radiographic avascular necrosis, though there was progressive growth deformity in only one. There was a much higher incidence among cases treated for unstable reduction by tenotomy, plaster spica and then the splint, 20 of 33 hips (60.6%) showing radiographic signs, though only one led to progressive abnormality. Of seven patients treated by adductor tenotomy and the splint no case of avascular necrosis was encountered. In the whole series the incidence of significant long-term growth disturbance in children treated in this splint was 0.7%. The great majority of our cases of avascular necrosis were attributable to manipulation and plaster, not to the subsequent use of a splint


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 1 | Pages 25 - 28
1 Jan 1985
Heikkila E Ryoppy S Louhimo I

Fifty-one infants with limited abduction of the hip and acetabular dysplasia were, between 1969 and 1975, treated with abduction-adduction exercises, administered by the parents; no abduction devices were used. In 1983 a follow-up examination was carried out on 41 of these patients. Although at birth these children had characteristics similar to patients with congenital dislocation of the hip, none of their hips dislocated. At birth acetabular measurements showed that half the children had severe dysplasia and the other half slight dysplasia; the difference between the affected and the healthy hips was significant. At follow-up the gait was normal in all the patients. Movements at the hips were symmetrical and within normal limits in all but one patient. The acetabular angle, the centre-edge angle, the shaft-neck angle, the hip ratio, and the size of the femoral head were the same on the previously affected side as on the normal side. Nineteen of the children followed up had preferred lying on one side and dysplasia of the upper hip had developed. The significance of the sleeping position on the development of acetabular dysplasia is discussed


The Journal of Bone & Joint Surgery British Volume
Vol. 56-B, Issue 1 | Pages 44 - 58
1 Feb 1974
Ring PA

1. A thousand arthritic hips have been replaced by an uncemented metal-on-metal prosthesis, and 942 followed by annual review. The mortality of the operation has been 1·1 per cent, the rate of deep-seated infection 0·7 per cent and the incidence of dislocation 0·3 per cent. 2. Of 169 hips replaced by an earlier type of the prosthesis and followed for five to eight years, 45 per cent have remained excellent and 29 per cent good, but 14 per cent have required revision, mainly for loosening of the femoral component. 3. The current types of prosthesis, now used for five years, have given excellent results in 69 per cent and good results in 21 per cent of 535 patients followed for one to five years. Revision for loosening has been necessary in 2 per cent. 4. The improvement in results has been obtained by the introduction of a tapered screw thread on the pelvic component, and by a range of femoral components that ensures a good cortical fit


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 6 | Pages 937 - 942
1 Nov 1995
Ljung P Jonsson K Rydholm U

We reviewed 50 capitellocondylar elbow replacements performed by the lateral approach in 42 rheumatoid patients, at a median follow-up of three years. There were two major and 17 minor complications; 18 were early and one was late. Eight elbows required reoperation: soft-tissue surgery was performed in seven and prosthesis removal in one because of a deep infection. There were few problems of instability, but one patient sustained a traumatic dislocation which was stabilised after ligament reconstruction. Wound healing was delayed in two of five elbows which had been immobilised postoperatively for only five days, but healing was rapid in 45 elbows immobilised for 12 days. There was transient ulnar-nerve palsy postoperatively in 11 patients, with permanent palsy in three. All elbows were painfree or only slightly painful at follow-up; 49 were stable and 43 had a range of motion sufficient for activities of daily living. Radiological loosening of the humeral component was suspected in one asymptomatic elbow. The lateral approach is recommended for use with the capitellocondylar type of prosthesis in rheumatoid elbows with reasonably well-preserved bone stock


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 2 | Pages 177 - 182
1 Mar 2001
Taylor AH Shannon M Whitehouse SL Lee MB Learmonth ID

We describe the results of 76 total arthroplasties of the hip for stage-III or stage-IV avascular necrosis of the femoral head. Harris Galante Porous cups were used in 63 patients between 1986 and 1994 and followed prospectively. We reviewed 70 hips with a follow-up of more than five years (mean 7.6). At the latest review the mean Harris Hip Score had improved from a preoperative value of 29 ± 14.7 to 94 ± 6.8. Radiologically, there was no evidence of acetabular migration. The rate of revision for the femoral component was 8.6%, three being undertaken for loosening and three to allow downsizing of the femoral head. The rate of revision for the acetabular component was 7.1% (five cups). At the time of revision none of the cups was clinically loose, and only required the liner to be changed. The rate of complications was low with no case of deep infection or dislocation, but nine of the 76 hips (11.8%) showed grade-III heterotopic ossification. Previous studies of patients undergoing cemented total hip arthroplasty for the treatment of advanced avascular necrosis have indicated a high incidence of loosening of the acetabular component. Our findings show good medium-term results using the Harris Galante Porous cup for acetabular reconstruction, together with a variety of cemented femoral components, for the treatment of this difficult problem


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 4 | Pages 544 - 547
1 Jul 1994
Benjamin B Khan M

We reviewed 190 children with brucellosis admitted over a 7.8-year period. Seventy of these had articular involvement (36%) and the most common site was the hip (18%). All but one patient had unilateral infection. The hip was the only joint infected in 20 patients (57%). The next most common articular site was the knee. All patients had painful limitation of movement and this was the only articular sign in 28 (80%). Extra-articular signs included fever and hepatosplenomegaly. Brucella infection should be considered in every child from an endemic area who presents with fever and joint symptoms. The insidious onset and a normal or low leucocyte count help the differentiation from acute septic arthritis. Children with hip involvement had a slower response to treatment, longer hospital stays and a higher incidence of complications and relapse than those without. Complications included dislocation (n = 4) and avascular necrosis of the femoral head (n = 1). Treatment by combination chemotherapy for 6 to 12 weeks usually achieves cure and prevents relapse. A multidisciplinary team approach to management is recommended


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 1 | Pages 31 - 34
1 Jan 2006
Loughead JM Starks I Chesney D Matthews JNS McCaskie AW Holland JP

Resurfacing arthroplasty of the hip is being performed more frequently in the United Kingdom. The majority of these patients are younger than 55 years of age, and in this group the key benefits include conservation of femoral bone stock and the potential reduction in the rate of dislocation afforded by the larger resurfacing head. Early aseptic loosening is well recognised in patients younger than 55 years of age, and proponents of resurfacing believe that the improved wear characteristics of the metal-on-metal bearing may improve the long-term survival of this implant. There has been some concern, however, that resurfacing may not be conservative of acetabular bone. We compared a series of 33 consecutive patients who had a hybrid total hip arthroplasty with an uncemented acetabular component and a cemented femoral implant, with 35 patients undergoing a Birmingham hip resurfacing arthroplasty. We compared the diameter of the implanted acetabulum in both groups and, because they were not directly comparable, we corrected for patient size by measuring the diameter of the contralateral femoral head. The data were analysed using unpaired t-tests and analysis of covariance. There was a significantly larger acetabulum in the Birmingham arthroplasty group (mean diameter 56.6 mm vs 52.0 mm; p < 0.001). However, this group had a significantly larger femoral head diameter on the contralateral side (p = 0.03). Analysis of covariance revealed a significant difference between the mean size of the acetabular component implanted in the two operations. The greatest difference in the size of acetabulum was in those patients with a larger diameter of the femoral head. This study shows that more bone is removed from the acetabulum in hip resurfacing than during hybrid total hip arthroplasty, a difference which is most marked in larger patients


Bone & Joint 360
Vol. 6, Issue 4 | Pages 2 - 7
1 Aug 2017
Titchener AG Tambe AA Clark DI


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 5 | Pages 777 - 781
1 Nov 1989
Nilsson L Stromqvist B Thorngren K

We report a series of 640 consecutive cervical hip fractures which were followed prospectively for two years after primary internal fixation with two hook-pins. Secondary arthroplasties were performed as salvage procedures in 75 cases and the early outcome of these was studied retrospectively. The mean time in hospital was 25 days for prosthetic replacement, though 60% of the patients had other medical conditions considered as risk factors. Mortality was 5% after six months and 8% after one year. Dislocation was seen in 11% and additional surgery was required in 4%. There was one case of deep infection and one supracondylar femoral fracture. In some cases there was considerable delay between the primary and secondary operation due to lack of awareness of functional deterioration, but although many patients had poor mobility before the secondary operation this was greatly improved within six weeks of the arthroplasty. We conclude that elective secondary hip arthroplasty for failure of fracture fixation is a safe and successful procedure. Once the decision to perform an arthroplasty is taken, this should be done without delay to avoid deterioration of function


The Journal of Bone & Joint Surgery British Volume
Vol. 65-B, Issue 4 | Pages 405 - 411
1 Aug 1983
Freeman M Bradley G

Clinical experience of the ICLH method of resurfacing the hip now spans 10 years. The first 36 arthroplasties, performed between 1972 and 1974, have been previously reported. This review covers in detail 204 such arthroplasties performed between 1975 and 1979 using a standard operative technique and prosthesis; these hips were consecutive and entirely unselected. Follow-up averaged 3.2 years (range two to six years). Successful hips are comparable to hips successfully replaced with stemmed prostheses. The rates of perioperative complications and failure due to infection, ectopic ossification, fracture of the femoral neck, and dislocation are favourably comparable to rates reported for stemmed total hip arthroplasties. The rate of aseptic loosening (17 per cent) greatly exceeded that found for stemmed total hip arthroplasties. Errors of patient selection, operative technique and prosthetic design have been identified. It is concluded that, although resurfacing arthroplasty of the hip may be an appealing procedure with theoretical advantages in certain instances, patient selection is essential, operative technique is demanding and changes in the design of the prosthesis are required. The procedure is still in evolution and therefore it should not yet be generally employed


The Journal of Bone & Joint Surgery British Volume
Vol. 42-B, Issue 1 | Pages 11 - 20
1 Feb 1960
Eyre-Brook AL

A series of ten infants is reported, seven of whom showed evidence of osteomyelitis of the upper end of the femur; the remaining three did not, but presented with an acute subluxation of the hip in a febrile illness. Four sequelae among the seven more severe cases were: 1) destruction of the capital epiphysis with dislocation at the hip; 2) destruction of the capital epiphysis, the femoral neck remaining in the acetabulum; 3) destruction of the epiphysial plate with the femoral head, remaining in the acetabulum, connected to the femoral neck by a fibrous union; 4) recovery with coxa magna but no other deformity. The streptococcus plays a greater part in this osteomyelitis of infancy than in osteomyelitis of older children, but various other organisms were identified. The organism should be sought by blood culture as well as from the local lesion. Aspiration of the hip, treatment of the hip in abduction and the use of the appropriate antibiotic are recommended. If there is marked swelling and induration, freer release of the pus is strongly advised. Controlled abduction osteotomy plays a useful part in stabilising the femoral neck in the acetabulum or in stabilising the femoral neck beneath the capital epiphysis, but may usefully be preceded by an arthrograph because late ossification of a detached head sometimes occurs


The Journal of Bone & Joint Surgery British Volume
Vol. 41-B, Issue 3 | Pages 590 - 599
1 Aug 1959
Ramamurti P Taylor HE

1 . Young Wistar rats fed on a diet containing 0·3 per cent semicarbazide hydrochloride developed the characteristic lesions of osteolathyrism. This consisted of kyphoscoliosis, displacement of epiphyses and dislocations of joints. A pathological study of the skeletal lesions showed widening, disorganisation and tears of the epiphysial plate with the zone of maturing cartilage showing the greatest increase in width. The severe kyphoscoliosis was due to a derangement and displacement at and through the epiphysial plates of the twelfth thoracic or first lumbar vertebra. 2. Some of the compounds that are known to produce osteolathyrism in laboratory animals are beta aminopropionitrile, amino acetonitrile, mercaptoethylamine and semicarbazide. The mode of action of the lathyrogenic compounds was analysed in the light of a number of experiments done in this laboratory. 3. lt is possible that they interfere with the metabolism of the epiphysial plate. There appears to be a decreased polymerisation of the ground substance of the epiphysial cartilage, but the exact metabolic reaction involved is not known. Other chemicals of similar structure, with the same reactive groups, did not show lathyrogenic properties. It is concluded that it is not a particular chemical structure, configuration or specific reactive group that is responsible for the production of osteolathyrism. The chemistry of the lesions still remains to be solved