Advertisement for orthosearch.org.uk
Results 1641 - 1660 of 2553
Results per page:
The Bone & Joint Journal
Vol. 97-B, Issue 6 | Pages 749 - 754
1 Jun 2015
Syed MA Hutt NJ Shah N Edge AJ

This study reports the results of 38 total hip arthroplasties (THAs) in 33 patients aged <  50 years, using the JRI Furlong hydroxyapatite ceramic (HAC)-coated femoral component. This represents an update of previous reports of the same cohort at ten and 16 years, which were reported in 2004 and 2009, respectively. We describe the survival, radiological and functional outcomes at a mean follow-up of 21 years (17 to 25). Of the surviving 34 THAs, one underwent femoral revision for peri-prosthetic fracture after 21 years, and one patient (one hip) was lost to follow-up. Using aseptic loosening as the end-point, 12 hips (31.5%) needed acetabular revision but none needed femoral revision, demonstrating 100% survival (95% confidence interval 89 to 100).

In young patients with high demands, the Furlong HAC–coated femoral component gives excellent long-term results.

Cite this article: Bone Joint J 2015;97-B:749–54.


The Bone & Joint Journal
Vol. 97-B, Issue 6 | Pages 755 - 761
1 Jun 2015
Flatøy B Röhrl SM Rydinge J Dahl J Diep LM Nordsletten L

Cemented femoral stems with force closed fixation designs have shown good clinical results despite high early subsidence. A new triple-tapered stem in this category (C-stem AMT) was introduced in 2005. This study compares this new stem with an established stem of similar design (Exeter) in terms of migration (as measured using radiostereometric analysis), peri-prosthetic bone remodelling (measured using dual energy x-ray densitometry, DXA), Oxford Hip Score, and plain radiographs.

A total of 70 patients (70 hips) with a mean age of 66 years (53 to 78) were followed for two years. Owing to missing data of miscellaneous reasons, the final analysis represents data from 51 (RSA) and 65 (DXA) patients. Both stems showed a typical pattern of migration: Subsidence and retroversion that primarily occurred during the first three months. C-stem AMT subsided less during the first three months (p = 0.01), before stabilising at a subsidence rate similar to the Exeter stem from years one to two. The rate of migration into retroversion was slightly higher for C-stem AMT during the second year (p = 0.03). Whilst there were slight differences in movement patterns between the stems, the C-stem AMT exhibits good early clinical outcomes and displays a pattern of migration and bone remodelling that predicts good clinical performance.

Cite this article: Bone Joint J 2015;97-B:755–61.


The Bone & Joint Journal
Vol. 97-B, Issue 5 | Pages 649 - 653
1 May 2015
Hawi N Kendoff D Citak M Gehrke T Haasper C

Knee arthrodesis is a potential salvage procedure for limb preservation after failure of total knee arthroplasty (TKA) due to infection. In this study, we evaluated the outcome of single-stage knee arthrodesis using an intramedullary cemented coupled nail without bone-on-bone fusion after failed and infected TKA with extensor mechanism deficiency. Between 2002 and 2012, 27 patients (ten female, 17 male; mean age 68.8 years; 52 to 87) were treated with septic single-stage exchange. Mean follow-up duration was 67.1months (24 to 143, n = 27) (minimum follow-up 24 months) and for patients with a minimum follow-up of five years 104.9 (65 to 143,; n = 13). A subjective patient evaluation (Short Form (SF)-36) was obtained, in addition to the Visual Analogue Scale (VAS). The mean VAS score was 1.44 (SD 1.48). At final follow-up, four patients had recurrent infections after arthrodesis (14.8%). Of these, three patients were treated with a one-stage arthrodesis nail exchange; one of the three patients had an aseptic loosening with a third single-stage exchange, and one patient underwent knee amputation for uncontrolled sepsis at 108 months. All patients, including the amputee, indicated that they would choose arthrodesis again. Data indicate that a single-stage knee arthrodesis offers an acceptable salvage procedure after failed and infected TKA.

Cite this article: Bone Joint J 2015;97-B:649–53.


The Bone & Joint Journal
Vol. 95-B, Issue 9 | Pages 1178 - 1183
1 Sep 2013
Li H Mao Y Oni JK Dai K Zhu Z

In developmental dysplasia of the hip (DDH), a bone defect is often observed superior to the acetabulum after the reconstruction at the level of the true acetabulum during total hip replacement (THR). However, the essential amount of uncemented acetabular component coverage required for a satisfactory outcome remains controversial. The purpose of this study was to assess the stability and function of acetabular components with a lack of coverage > 30% (31% to 50%). A total of 760 DDH patients underwent THR with acetabular reconstruction at the level of the true floor. Lack of coverage above the acetabular component of > 30% occurred in 56 patients. Intra-operatively, autogenous morcellised bone grafts were used to fill the uncovered portion. Other than two screws inserted through the acetabular shell, no additional structural supports were used in these hips. In all, four patients were lost to follow-up. Therefore, 52 patients (52 hips, 41 women and 11 men) with a mean age of 60.1 years (42 to 78) were available for this study at a mean of 4.8 years (3 to 7). There were no instances of prosthesis revision or marked loosening during the follow-up. The Harris hip score improved from a mean of 40.7 points (sd 12.2) pre-operatively to 91.1 (sd 5.0) at the last follow-up. Radiological analysis with medical imaging software allowed us to calculate the extent of the uncoverage in terms of the uncovered arc of the implant as viewed on the anteroposterior pelvic radiograph. From this we propose that up to 17 mm of lateral undercoverage in the presence of a stable initial implantation in the presence of bone autografting, with an inclination angle of the acetabular component between 40° and 55°, is acceptable. This represents undercoverage of ≤ 50%.

Cite this article: Bone Joint J 2013;95-B:1178–83.


Bone & Joint 360
Vol. 4, Issue 2 | Pages 35 - 36
1 Apr 2015
Forward DP Lewis CP


Bone & Joint 360
Vol. 3, Issue 1 | Pages 42 - 45
1 Feb 2014
Shah N Hodgkinson J

Hip replacement is a very successful operation and the outcome is usually excellent. There are recognised complications that seem increasingly to give rise to litigation. This paper briefly examines some common scenarios where litigation may be pursued against hip surgeons. With appropriate record keeping, consenting and surgical care, the claim can be successfully defended if not avoided. We hope this short summary will help to highlight some common pitfalls. There is extensive literature available for detailed study.


The Bone & Joint Journal
Vol. 95-B, Issue 11 | Pages 1508 - 1513
1 Nov 2013
Ploegmakers JJW The B Brutty M Ackland TR Wang AW

The aim of this study was to determine the effect of a Galeazzi fracture on the strength of pronation and supination at a mean of two years after surgical treatment. The strength of pronation and supination was measured in varying rotational positions of the forearm of ten male patients (mean age 38.9 years (21 to 64)) who had undergone plate fixation for a Galeazzi fracture. The stability of the distal radioulnar joint was assessed, and a clinical assessment using the quick-Disabilities of the Arm Shoulder and Hand (quickDASH) questionnaire and patient-related wrist examination (PRWE) scores was undertaken. In addition, the strength of pronation and supination was measured in a male control group of 42 healthy volunteers (mean age 21.8 years (18 to 37)).

The mean absolute loss of strength of supination in the injured compared with the non-injured arm throughout all ranges of forearm rotation was 16.1 kg (sem 5.3), corresponding to a relative loss of 12.5% (95% confidence interval (CI) 3.6 to 21.4). For the strength of pronation, the mean loss was 19.1 kg (sem 4.5), corresponding to a relative loss of 27.2% (95% CI 14.2 to 40.1). Loss of strength of supination following a Galeazzi fracture correlated with poor quickDASH (p = 0.03) and PRWE scores (p < 0.01).

Loss of strength of pronation (27.2%), and of supination (12.5%) in particular, after a Galeazzi fracture is associated with worse clinical scores, highlighting the importance of supination of the forearm in function of the upper limb.

Cite this article: Bone Joint J 2013;95-B:1508–13.


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 31 - 36
1 Nov 2013
Gustke K

Total hip replacement for developmental hip dysplasia is challenging. The anatomical deformities on the acetabular and femoral sides are difficult to predict. The Crowe classification is usually used to describe these cases – however, it is not a very helpful tool for pre-operative planning. Small acetabular components, acetabular augments, and modular femoral components should be available for all cases. Regardless of the Crowe classification, the surgeon must be prepared to perform a femoral osteotomy for shortening, or to correct rotation, and/or angulation.

Cite this article: Bone Joint J 2013;95-B, Supple A:31–6.


Bone & Joint 360
Vol. 3, Issue 4 | Pages 17 - 19
1 Aug 2014

The August 2014 Foot & Ankle Roundup360 looks at: calcaneotibial nail in ankle fractures; reamer irrigator aspirator for ankle fusion; periprosthetic bone infection; infection in ankle fixation; cheap and cheerful OK in MTP fusion plates; sliding fibular graft for peroneal tendon pathology and fusion for failed ankle replacement.


The Bone & Joint Journal
Vol. 97-B, Issue 4 | Pages 473 - 477
1 Apr 2015
Bone MC Dold P Flohr M Preuss R Joyce TJ Aspden RM Holland J Deehan D

Concerns have been raised that deformation of acetabular shells may disrupt the assembly process of modular prostheses. In this study we aimed to examine the effect that the strength of bone has on the amount of deformation of the acetabular shell. The hypothesis was that stronger bone would result in greater deformation. A total of 17 acetabular shells were inserted into the acetabula of eight cadavers, and deformation was measured using an optical measuring system. Cores of bone from the femoral head were taken from each cadaver and compressed using a materials testing machine. The highest peak modulus and yield stress for each cadaver were used to represent the strength of the bone and compared with the values for the deformation and the surgeon’s subjective assessment of the hardness of the bone. The mean deformation of the shell was 129 µm (3 to 340). No correlation was found between deformation and either the maximum peak modulus (r² = 0.011, t = 0.426, p = 0.676) or the yield stress (r² = 0.024, t = 0.614, p = 0.549) of the bone. Although no correlation was found between the strength of the bone and deformation, the values for the deformation observed could be sufficient to disrupt the assembly process of modular acetabular components.

Cite this article: Bone Joint J 2015; 97-B:473–7.


The Bone & Joint Journal
Vol. 96-B, Issue 7 | Pages 884 - 888
1 Jul 2014
Insull PJ Cobbett H Frampton CM Munro JT

We compared the rate of revision for instability after total hip replacement (THR) when lipped and non-lipped acetabular liners were used. We hypothesised that the use of a lipped liner in a modular uncemented acetabular component reduces the risk of revision for instability after primary THR. Using data from the New Zealand Joint Registry, we found that the use of a lipped liner was associated with a significantly decreased rate of revision for instability and for all other indications. Adjusting for the size of the femoral head, the surgical approach and the age and gender of the patient, this difference remained strongly significant (p < 0.001).

We conclude that evidence from the New Zealand registry suggests that the use of lipped liners with modular uncemented acetabular components is associated with a decreased rate of revision for instability after primary THR.

Cite this article: Bone Joint J 2014;96-B:884–8.


The Bone & Joint Journal
Vol. 95-B, Issue 11 | Pages 1514 - 1520
1 Nov 2013
D’Agostino P Barbier O

The osteoinductive properties of demineralised bone matrix have been demonstrated in animal studies. However, its therapeutic efficacy has yet to be proven in humans. The clinical properties of AlloMatrix, an injectable calcium-based demineralised bone matrix allograft, were studied in a prospective randomised study of 50 patients with an isolated unstable distal radial fracture treated by reduction and Kirschner (K-) wire fixation. A total of 24 patients were randomised to the graft group (13 men and 11 women, mean age 42.3 years (20 to 62)) and 26 to the no graft group (8 men and 18 women, mean age 45.0 years (17 to 69)).

At one, three, six and nine weeks, and six and 12 months post-operatively, patients underwent radiological evaluation, assessments for range of movement, grip and pinch strength, and also completed the Disabilities of Arm, Shoulder and Hand questionnaire. At one and six weeks and one year post-operatively, bone mineral density evaluations of both wrists were performed.

No significant difference in wrist function and speed of recovery, rate of union, complications or bone mineral density was found between the two groups. The operating time was significantly higher in the graft group (p = 0.004). Radiologically, the reduction parameters remained similar in the two groups and all AlloMatrix extraosseous leakages disappeared after nine weeks.

This prospective randomised controlled trial did not demonstrate a beneficial effect of AlloMatrix demineralised bone matrix in the treatment of this category of distal radial fractures treated by K-wire fixation.

Cite this article: Bone Joint J 2013;95-B:1514–20.


The Bone & Joint Journal
Vol. 95-B, Issue 5 | Pages 668 - 672
1 May 2013
Abdel MP Hattrup SJ Sperling JW Cofield RH Kreofsky CR Sanchez-Sotelo J

Instability after arthroplasty of the shoulder is difficult to correct surgically. Soft-tissue procedures and revision surgery using unconstrained anatomical components are associated with a high rate of failure. The purpose of this study was to determine the results of revision of an unstable anatomical shoulder arthroplasty to a reverse design prosthesis. Between 2004 and 2007, 33 unstable anatomical shoulder arthroplasties were revised to a reverse design. The mean age of the patients was 71 years (53 to 86) and their mean follow-up was 42 months (25 to 71). The mean time to revision was 26 months (4 to 164). Pain scores improved significantly (pre-operative visual analogue scale (VAS) of 7.2 (sd 1.6); most recent VAS 2.2 (sd 1.9); p = 0.001). There was a statistically significant increase in mean active forward elevation from 40.2° (sd 27.3) to 97.0° (sd 36.2) (p = 0.001). There was no significant difference in internal (p = 0.93) or external rotation (p = 0.40). Radiological findings included notching in five shoulders (15%) and heterotopic ossification of the inferior capsular region in three (9%). At the last follow-up 31 shoulders (94%) were stable. The remaining two shoulders dislocated at 2.5 weeks and three months post-operatively, respectively. According to the Neer rating system, there were 13 excellent (40%), ten satisfactory (30%) and ten unsatisfactory results (30%). Revision of hemiarthroplasty or anatomical total shoulder replacement for instability using a reverse design prosthesis gives good short-term results.

Cite this article: Bone Joint J 2013;95-B:668–72.


Bone & Joint 360
Vol. 2, Issue 4 | Pages 22 - 24
1 Aug 2013

The August 2013 Trauma Roundup360 looks at: reverse oblique fractures do better with a cephalomedullary device; locking screws confer no advantage in tibial plateau fractures; it’s all about the radius of curvature; radius of curvature revisited; radial head replacement in complex elbow reconstruction; stem cells in early fracture haematoma; heterotrophic ossification in forearms; and Boston in perspective.


The Bone & Joint Journal
Vol. 97-B, Issue 6 | Pages 771 - 779
1 Jun 2015
te Stroet MAJ Rijnen WHC Gardeniers JWM van Kampen A Schreurs BW

We report the clinical and radiographic outcomes of 208 consecutive femoral revision arthroplasties performed in 202 patients (119 women, 83 men) between March 1991 and December 2007 using the X-change Femoral Revision System, fresh-frozen morcellised allograft and a cemented polished Exeter stem. All patients were followed prospectively. The mean age of the patients at revision was 65 years (30 to 86). At final review in December 2013 a total of 130 patients with 135 reconstructions (64.9%) were alive and had a non re-revised femoral component after a mean follow-up of 10.6 years (4.7 to 20.9). One patient was lost to follow-up at six years, and their data were included up to this point. Re-operation for any reason was performed in 33 hips (15.9%), in 13 of which the femoral component was re-revised (6.3%). The mean pre-operative Harris hip score was 52 (19 to 95) (n = 73) and improved to 80 (22 to 100) (n = 161) by the last follow-up. Kaplan–Meier survival with femoral re-revision for any reason as the endpoint was 94.9% (95% confidence intervals (CI) 90.2 to 97.4) at ten years; with femoral re-revision for aseptic loosening as the endpoint it was 99.4% (95% CI 95.7 to 99.9); with femoral re-operation for any reason as the endpoint it was 84.5% (95% CI 78.3 to 89.1); and with subsidence ≥ 5 mm it was 87.3% (95% CI 80.5 to 91.8). Femoral revision with the use of impaction allograft bone grafting and a cemented polished stem results in a satisfying survival rate at a mean of ten years’ follow-up.

Cite this article: Bone Joint J 2015; 97-B:771–9.


The Bone & Joint Journal
Vol. 96-B, Issue 3 | Pages 339 - 344
1 Mar 2014
Saito T Kumagai K Akamatsu Y Kobayashi H Kusayama Y

Between 2003 and 2007, 99 knees in 77 patients underwent opening wedge high tibial osteotomy. We evaluated the effect of initial stable fixation combined with an artificial bone substitute on the mid- to long-term outcome after medial opening-wedge high tibial osteotomy (HTO) for medial compartmental osteoarthritis or spontaneous osteonecrosis of the knee in 78 knees in 64 patients available for review at a minimum of five years (mean age 68 years; 49 to 82). The mean follow-up was 6.5 years (5 to 10). The mean Knee Society knee score and function score improved from 49.6 (sd 11.4, 26 to 72) and 56.6 (sd 15.6, 5 to 100) before surgery to 88.1 (sd 12.5, 14 to 100) and 89.4 (sd 15.6, 5 to 100) at final follow-up (p <  0.001) respectively. There were no significant differences between patients aged ≥ 70 and < 70 years. The mean standing femorotibial angle was corrected significantly from 181.7° (sd 2.7°, 175° to 185°) pre-operatively to 169.7° (sd 2.4°, 164° to 175°) at one year’s follow-up (p < 0.001) and 169.6° (sd 3.0°, 157° to 179°) at the final follow-up (p = 0.69 vs one year).

Opening-wedge HTO using a stable plate fixation system combined with a bone substitute is a reliable procedure that provides excellent results. Although this treatment might seem challenging for older patients, our results strongly suggest that the results are equally good.

Cite this article: Bone Joint J 2014;96-B:339–44.


The Bone & Joint Journal
Vol. 97-B, Issue 5 | Pages 696 - 704
1 May 2015
Kenawey M Krettek C Addosooki A Salama W Liodakis E

Unstable pelvic injuries in young children with an immature pelvis have different modes of failure from those in adolescents and adults. We describe the pathoanatomy of unstable pelvic injuries in these children, and the incidence of associated avulsion of the iliac apophysis and fracture of the ipsilateral fifth lumbar transverse process (L5-TP). We retrospectively reviewed the medical records of 33 children with Tile types B and C pelvic injuries admitted between 2007 and 2014; their mean age was 12.6 years (2 to 18) and 12 had an immature pelvis. Those with an immature pelvis commonly sustained symphyseal injuries anteriorly with diastasis, rather than the fractures of the pubic rami seen in adolescents. Posteriorly, transsacral fractures were more commonly encountered in mature children, whereas sacroiliac dislocations and fracture-dislocations were seen in both age groups. Avulsion of the iliac apophysis was identified in eight children, all of whom had an immature pelvis with an intact ipsilateral L5-TP. Young children with an immature pelvis are more susceptible to pubic symphysis and sacroiliac diastasis, whereas bony failures are more common in adolescents. Unstable pelvic injuries in young children are commonly associated with avulsion of the iliac apophysis, particularly with displaced SI joint dislocation and an intact ipsilateral L5-TP.

Cite this article: Bone Joint J 2015; 97-B:696–704.


The Bone & Joint Journal
Vol. 96-B, Issue 8 | Pages 1029 - 1034
1 Aug 2014
Kashigar A Vincent A Gunton MJ Backstein D Safir O Kuzyk PRT

The purpose of this study was to identify factors that predict implant cut-out after cephalomedullary nailing of intertrochanteric and subtrochanteric hip fractures, and to test the significance of calcar referenced tip-apex distance (CalTAD) as a predictor for cut-out.

We retrospectively reviewed 170 consecutive fractures that had undergone cephalomedullary nailing. Of these, 77 met the inclusion criteria of a non-pathological fracture with a minimum of 80 days radiological follow-up (mean 408 days; 81 days to 4.9 years). The overall cut-out rate was 13% (10/77).

The significant parameters in the univariate analysis were tip-apex distance (TAD) (p <  0.001), CalTAD (p = 0.001), cervical angle difference (p = 0.004), and lag screw placement in the anteroposterior (AP) view (Parker’s ratio index) (p = 0.003). Non-significant parameters were age (p = 0.325), gender (p = 1.000), fracture side (p = 0.507), fracture type (AO classification) (p = 0.381), Singh Osteoporosis Index (p = 0.575), lag screw placement in the lateral view (p = 0.123), and reduction quality (modified Baumgaertner’s method) (p = 0.575). In the multivariate analysis, CalTAD was the only significant measurement (p = 0.001). CalTAD had almost perfect inter-observer reliability (interclass correlation coefficient (ICC) 0.901).

Our data provide the first reported clinical evidence that CalTAD is a predictor of cut-out. The finding of CalTAD as the only significant parameter in the multivariate analysis, along with the univariate significance of Parker’s ratio index in the AP view, suggest that inferior placement of the lag screw is preferable to reduce the rate of cut-out.

Cite this article: Bone Joint J 2014; 96-B:1029–34.


The Bone & Joint Journal
Vol. 97-B, Issue 2 | Pages 160 - 163
1 Feb 2015
Biemond JE Venkatesan S van Hellemondt GG

The long-term survival of the cementless Spotorno CLS femoral component in patients aged > 50 years at the time of arthroplasty was investigated. Survivorship analysis of a consecutive series of 85 patients (100 hips; under 50 years of age at a mean follow-up of 18.4 years (16.3 to 20.8)) was performed. The clinical and radiographic outcomes were satisfactory. The overall rate of survival of the femoral component was 93.5% (95% confidence interval (CI), 90.9 to 96.1) after 19 years. Survival with revision for aseptic loosening as the end point was 95.7% (95% CI 93.6 to 97.8%) at 19 years.

This study demonstrates an excellent long-term survival of the Spotorno CLS femoral component after 16 to 20 years in young patients undergoing total hip arthroplasty.

Cite this article: Bone Joint J 2015;97-B:160–3.


The Bone & Joint Journal
Vol. 96-B, Issue 7 | Pages 978 - 983
1 Jul 2014
Wadsten MÅ Sayed-Noor AS Englund E Buttazzoni GG Sjödén GO

This paper investigates whether cortical comminution and intra-articular involvement can predict displacement in distal radius fractures by using a classification that includes volar comminution as a separate parameter.

A prospective multicentre study involving non-operative treatment of distal radius fractures in 387 patients aged between 15 and 74 years (398 fractures) was conducted. The presence of cortical comminution and intra-articular involvement according to the Buttazzoni classification is described. Minimally displaced fractures were treated with immobilisation in a cast while displaced fractures underwent closed reduction with subsequent immobilisation. Radiographs were obtained after reduction, at 10 to 14 days and after union. The outcome measure was re-displacement or union.

In fractures with volar comminution (Buttazzoni type 4), 96% (53 of 55) displaced. In intra-articular fractures without volar comminution (Buttazzoni 3), 72% (84 of 117) displaced. In extra-articular fractures with isolated dorsal comminution (Buttazzoni 2), 73% (106 of 145) displaced while in non-comminuted fractures (Buttazzoni 1), 16 % (13 of 81 ) displaced.

A total of 32% (53 of 165) of initially minimally displaced fractures later displaced. All of the initially displaced volarly comminuted fractures re-displaced. Displacement occurred in 31% (63 of 205) of fractures that were still in good alignment after 10 to 14 days.

Regression analysis showed that volar and dorsal comminution predicted later displacement, while intra-articular involvement did not predict displacement. Volar comminution was the strongest predictor of displacement.

Cite this article: Bone Joint J 2014;96-B:978–83.