In the UK we have many surgeon inventors – surgeons who innovate and create new ways of doing things, who invent operations, who design new instruments to facilitate surgery or design new implants for using in patients. However truly successful surgeon inventors are a rare breed and they need to develop additional knowledge and skills during their career in order to push forward their devices and innovations. This article reviews my own experiences as a surgeon inventor and the highs and lows over the whole of my surgical career.
We retrospectively reviewed 11 consecutive patients with an infected reverse shoulder prosthesis. Patients were assessed clinically and radiologically, and standard laboratory tests were carried out. Peroperative samples showed Propionbacterium acnes in seven, coagulase-negative Staphylococcus in five, methicillin-resistant A one-stage revision arthroplasty reduces the cost and duration of treatment. It is reliable in eradicating infection and good functional outcomes can be achieved.
The treatment of a chronic posterior dislocation of the shoulder is often determined by the size of the associated impression fracture of the humeral head. Our hypothesis was that patients with a chronic unreduced posterior dislocation of the shoulder and a defect in the humeral head involving between 25% to 50% of the articular surface, would do better if reconstructed with an allograft from the femoral head rather than treated by a non-anatomical reconstruction. We reviewed ten men and three women with a mean age of 42 years (36 to 51) at a mean follow-up of 54 months (41 to 64) who had this procedure. At follow-up, nine had no pain or restriction of activities of daily living. Their mean Constant-Murley shoulder score was 86.8 (43 to 98). No patient had symptoms of instability of the shoulder. Reconstruction of the defect in the humeral head with an allograft provides good pain relief, stability and function for patients with a locked, chronic posterior dislocation where the defect involves between 25% and 50% of the circumference of the articular surface.
Most proximal humeral fractures are stable injuries of the ageing population, and can be successfully treated non-operatively. The management of the smaller number of more complex displaced fractures is more controversial and new fixation techniques have greatly increased the range of fractures that may benefit from surgery. This article explores current concepts in the classification and clinical aspects of these injuries, reviewing the indications, innovations and outcomes for the most common methods of treatment.
Metallosis after shoulder replacement has not previously been described in the literature. We report a patient who developed extensive metallosis after implantation of an uncemented Nottingham shoulder replacement. He underwent a revision procedure. Examination of the retrieved prosthesis showed that the titanium porous coating was separating from the humeral stem and becoming embedded in the ultra-high-molecular-weight polyethylene glenoid component, resulting in abrasive wear of the humeral component. There was metallosis despite exchange of the modular humeral head. Both components had to be exchanged to resolve the problem.
Between 2002 and 2008, 130 consecutive ankles were replaced with an hydroxyapatite (HA) and titanium-HA-coated Ankle Evolutive System total ankle prosthesis. Plain radiographs were analysed by two independent observers. Osteolytic lesions were classified by their size and location, with cavities >
10 mm in diameter considered to be ‘marked’. CT scanning was undertaken in all patients with marked osteolysis seen on the plain radiographs. Osteolytic lesions were seen on the plain films in 48 (37%) and marked lesions in 27 (21%) ankles. The risk for osteolysis was found to be 3.1 (95% confidence interval 1.6 to 5.9) times higher with implants with Ti-HA porous coating. Care should be taken with ankle arthroplasty until more is known about the reasons for these severe osteolyses.
Wear of polyethylene is associated with aseptic loosening of orthopaedic implants and has been observed in hip and knee prostheses and anatomical implants for the shoulder. The reversed shoulder prostheses have not been assessed as yet. We investigated the volumetric polyethylene wear of the reversed and anatomical Aequalis shoulder prostheses using a mathematical musculoskeletal model. Movement and joint stability were achieved by EMG-controlled activation of the muscles. A non-constant wear factor was considered. Simulated activities of daily living were estimated from After one year of use, the volumetric wear was 8.4 mm3 for the anatomical prosthesis, but 44.6 mm3 for the reversed version. For the anatomical prosthesis the predictions for contact pressure and wear were consistent with biomechanical and clinical data. The abrasive wear of the polyethylene in reversed prostheses should not be underestimated, and further analysis, both experimental and clinical, is required.
There are few reports in the literature of the diagnosis and treatment of the infected shoulder arthroplasty. Most deal with resection arthroplasty and two-stage exchange surgery. We present our results of one-stage exchange operation as treatment for the infected shoulder arthroplasty. Our group comprised 16 patients (ten men, six women) with 16 infected arthroplasties. By the time of follow-up, two patients had died (mean 5.8 years), two could not be located and three had already undergone revision surgery. Nine patients were thus available for clinical examination and assessment. The infections were largely caused by staphylococci, Further revision was performed in three patients. One sustained a peri-prosthetic humeral fracture, another developed an acromial pseudarthrosis after transacromial surgery and the third suffered recurrent dislocations. No patient had a recurrence of infection. A one-stage exchange procedure using antibiotic-loaded bone cement eradicated infection in all our patients and we suggest that such a procedure is at least as successful as either a resection arthroplasty or a two-stage exchange in the management of the infected shoulder arthroplasty.
Iontophoresis is a novel technique which may be used to facilitate the movement of antibiotics into the substance of bone using an electrical potential applied externally. We have examined the rate of early infection in allografts following application of this technique in clinical practice. A total of 31 patients undergoing revision arthroplasty or surgery for limb salvage received 34 iontophoresed sequential allografts, of which 26 survived for a minimum of two years. The mean serum antibiotic levels after operation were low (gentamicin 0.37 mg/l (0.2 to 0.5); flucloxacillin 1 mg/l (0 to 1) and the levels in the drains were high (gentamicin 40 mg/l (2.5 to 131); flucloxacillin 17 mg/l (1 to 43). There were no early deep infections. Two late infections were presumed to be haemotogenous; 28 of the 34 allografts were retained. In 12 patients with pre-existing proven infection further infection has not occurred at a mean follow-up of 51 months (24 to 82).