Advertisement for orthosearch.org.uk
Results 141 - 160 of 321
Results per page:
The Bone & Joint Journal
Vol. 100-B, Issue 10 | Pages 1303 - 1309
1 Oct 2018
Nodzo SR Chang C Carroll KM Barlow BT Banks SA Padgett DE Mayman DJ Jerabek SA

Aims

The aim of this study was to evaluate the accuracy of implant placement when using robotic assistance during total hip arthroplasty (THA).

Patients and Methods

A total of 20 patients underwent a planned THA using preoperative CT scans and robotic-assisted software. There were nine men and 11 women (n = 20 hips) with a mean age of 60.8 years (sd 6.0). Pelvic and femoral bone models were constructed by segmenting both preoperative and postoperative CT scan images. The preoperative anatomical landmarks using the robotic-assisted system were matched to the postoperative 3D reconstructions of the pelvis. Acetabular and femoral component positions as measured intraoperatively and postoperatively were evaluated and compared.


Bone & Joint 360
Vol. 7, Issue 4 | Pages 31 - 33
1 Aug 2018


The Bone & Joint Journal
Vol. 100-B, Issue 12 | Pages 1609 - 1617
1 Dec 2018
Malhas AM Granville-Chapman J Robinson PM Brookes-Fazakerley S Walton M Monga P Bale S Trail I

Aims

We present our experience of using a metal-backed prosthesis and autologous bone graft to treat gross glenoid bone deficiency.

Patients and Methods

A prospective cohort study of the first 45 shoulder arthroplasties using the SMR Axioma Trabecular Titanium (TT) metal-backed glenoid with autologous bone graft. Between May 2013 and December 2014, 45 shoulder arthroplasties were carried out in 44 patients with a mean age of 64 years (35 to 89). The indications were 23 complex primary arthroplasties, 12 to revise a hemiarthroplasty or resurfacing, five for aseptic loosening of the glenoid, and five for infection.


The Bone & Joint Journal
Vol. 100-B, Issue 7 | Pages 898 - 902
1 Jul 2018
Lachiewicz PF O’Dell JA

Aims

To report our experience with trunnion corrosion following metal-on-polyethylene total hip arthroplasty, in particular to report the spectrum of presentation and determine the mean time to presentation.

Patients and Methods

We report the presenting symptoms and signs, intraoperative findings, and early results and complications of operative treatment in nine patients with a mean age of 74 years (60 to 86). The onset of symptoms was at a mean of seven years (3 to 18) after index surgery.


Bone & Joint 360
Vol. 6, Issue 2 | Pages 33 - 34
1 Apr 2017


The Bone & Joint Journal
Vol. 100-B, Issue 8 | Pages 1117 - 1124
1 Aug 2018
Eamsobhana P Chalayon O Kaewpornsawan K Ariyawatkul T

Aims

Delayed diagnosis is a well-known complication of a Monteggia fracture-dislocation. If left untreated, the dislocated radial head later becomes symptomatic. The purposes of this study were firstly, to evaluate the clinical and radiological results of open reduction of the radial head and secondly, to identify the factors that may affect the outcome of this procedure.

Materials and Methods

This retrospective study evaluated 30 children with a chronic Monteggia lesion. There were 18 boys and 12 girls with a mean age of 7.4 years (4 to 13) at the time of open reduction. The mean interval to surgery, after the initial fracture, was 23.4 months (6 to 120). Clinical grading used a Kim modified elbow score: radiological outcome was recorded. The effect of the patient’s age, gender, duration from initial injury, Bado classification, and annular ligament reconstruction were analyzed. The mean follow-up was 42.2 months (15 to 20).


The Bone & Joint Journal
Vol. 100-B, Issue 8 | Pages 1010 - 1017
1 Aug 2018
Jain S Magra M Dube B Veysi VT Whitwell GS Aderinto JB Emerton ME Stone MH Pandit HG

Aims

This study aimed to evaluate implant survival of reverse hybrid total hip arthroplasty (THA) at medium-term follow-up.

Patients and Methods

A consecutive series of 1082 THAs in 982 patients with mean follow-up of 7.9 years (5 to 11.3) is presented. Mean age was 69.2 years (21 to 94). Of these, 194 (17.9%) were in patients under 60 years, 663 (61.3%) in female patients and 348 (32.2%) performed by a trainee. Head size was 28 mm in 953 hips (88.1%) or 32 mm in 129 hips (11.9%). Survival analysis was performed and subgroups compared using log rank tests.


Bone & Joint 360
Vol. 7, Issue 3 | Pages 31 - 34
1 Jun 2018


Bone & Joint 360
Vol. 7, Issue 2 | Pages 40 - 42
1 Apr 2018
Foy MA


The Bone & Joint Journal
Vol. 100-B, Issue 7 | Pages 853 - 861
1 Jul 2018
Leunig M Hutmacher JE Ricciardi BF Impellizzeri FM Rüdiger HA Naal FD

Aims

The classical longitudinal incision used for the direct anterior approach (DAA) to the hip does not follow the tension lines of the skin and can lead to impaired wound healing and poor cosmesis. The purpose of this retrospective study was to determine the satisfaction with the scar, and functional and radiographic outcomes comparing the classic longitudinal incision with a modified skin crease ‘bikini’ when the DAA is used for total hip arthroplasty (THA).

Patients and Methods

A total of 964 patients (51% female; 59% longitudinal, 41% ‘bikini’) completed a follow-up questionnaire between two and four years postoperatively, including the Oxford Hip Score (OHS), the University of North Carolina ‘4P’ scar scale (UNC4P) and two items for assessing the aesthetic appearance of the scar and symptoms of numbness. The positioning of the components, rates of heterotopic ossification (HO) and rates of revision were assessed.


The Bone & Joint Journal
Vol. 100-B, Issue 4 | Pages 646 - 651
1 Apr 2018
Attias N Thabet AM Prabhakar G Dollahite JA Gehlert RJ DeCoster TA

Aims

This study reviews the use of a titanium mesh cage (TMC) as an adjunct to intramedullary nail or plate reconstruction of an extra-articular segmental long bone defect.

Patients and Methods

A total of 17 patients (aged 17 to 61 years) treated for a segmental long bone defect by nail or plate fixation and an adjunctive TMC were included. The bone defects treated were in the tibia (nine), femur (six), radius (one), and humerus (one). The mean length of the segmental bone defect was 8.4 cm (2.2 to 13); the mean length of the titanium mesh cage was 8.3 cm (2.6 to 13). The clinical and radiological records of the patients were analyzed retrospectively.


Bone & Joint 360
Vol. 7, Issue 1 | Pages 35 - 37
1 Feb 2018


Bone & Joint 360
Vol. 7, Issue 1 | Pages 22 - 24
1 Feb 2018


The Bone & Joint Journal
Vol. 100-B, Issue 1_Supple_A | Pages 50 - 54
1 Jan 2018
Berend ME Berend KR Lombardi AV Cates H Faris P

Aims

Few reconstructive techniques are available for patients requiring complex acetabular revisions such as those involving Paprosky type 2C, 3A and 3B deficiencies and pelvic discontinuity. Our aim was to describe the development of the patient specific Triflange acetabular component for use in these patients, the surgical technique and mid-term results. We include a description of the pre-operative CT scanning, the construction of a model, operative planning, and surgical technique. All implants were coated with porous plasma spray and hydroxyapatite if desired.

Patients and Methods

A multicentre, retrospective review of 95 complex acetabular reconstructions in 94 patients was performed. A total of 61 (64.2%) were female. The mean age of the patients was 66 (38 to 85). The mean body mass index was 29 kg/m2 (18 to 51). Outcome was reported using the Harris Hip Score (HHS), complications, failures and survival.


The Bone & Joint Journal
Vol. 95-B, Issue 9 | Pages 1290 - 1294
1 Sep 2013
Lim KBL Lim CT Tawng DK

Supracondylar humeral fractures are common in children, but there are no classification systems or radiological parameters that predict the likelihood of having to perform an open reduction. In a retrospective case–control study we evaluated the use of the medial spike angle and fracture tip–skin distance to predict the mode of reduction (closed or open) and the operating time in fractures with posterolateral displacement. A total of 21 patients (4.35%) with a small medial spike angle (< 45°) were identified from a total of 494 patients, and 42 patients with a medial spike angle of > 45° were randomly selected as controls. The medial spike group had significantly smaller fracture tip–skin distances (p < 0.001), longer operating times (p = 0.004) and more complications (p = 0.033) than the control group. There was no significant difference in the mode of reduction and a composite outcome measure. After adjustments for age and gender, only fracture tip–skin distance remained significantly associated with the operating time (β = -0.724, p = 0.042) and composite outcome (OR 0.863 (95% confidence interval 0.746 to 0.998); p = 0.048).

Paediatric orthopaedic surgeons should have a lower threshold for open reduction when treating patients with a small medial spike angle and a small fracture tip–skin distance.

Cite this article: Bone Joint J 2013;95-B:1290–4.


The Bone & Joint Journal
Vol. 97-B, Issue 7 | Pages 967 - 972
1 Jul 2015
Hussey MM Hussey SE Mighell MA

Failed internal fixation of a fracture of the proximal humerus produces many challenges with limited surgical options. The aim of this study was to evaluate the clinical outcomes after the use of a reverse shoulder arthroplasty under these circumstances. Between 2007 and 2012, 19 patients (15 women and four men, mean age 66 years; 52 to 82) with failed internal fixation after a proximal humeral fracture, underwent implant removal and reverse shoulder arthroplasty (RSA). The mean follow-up was 36 months (25 to 60). The mean American Shoulder and Elbow Score improved from 27.8 to 50.1 (p = 0.019). The mean Simple Shoulder Test score improved from 0.7 to 3.2 (p = 0.020), and the mean visual analogue scale for pain improved from 6.8 to 4.3 (p = 0.012). Mean forward flexion improved from 58.7° to 101.1° (p < 0.001), mean abduction from 58.7° to 89.1° (p = 0.012), mean external rotation from 10.7° to 23.1° (p = 0.043) and mean internal rotation from buttocks to L4 (p = 0.034). A major complication was recorded in five patients (26%) (one intra-operative fracture, loosening of the humeral component in two and two peri-prosthetic fractures). A total of 15 patients (79%) rated their outcome as excellent or good, one (5%) as satisfactory, and three (16%) as unsatisfactory.

An improvement in outcomes and pain can be expected when performing a RSA as a salvage procedure after failed internal fixation of a fracture of the proximal humerus. Patients should be cautioned about the possibility for major complications following this technically demanding procedure.

Cite this article: Bone Joint J 2015;97-B:967–72.


The Bone & Joint Journal
Vol. 97-B, Issue 9 | Pages 1271 - 1278
1 Sep 2015
Märdian S Schaser KD Hinz P Wittenberg S Haas NP Schwabe P

This study compared the quality of reduction and complication rate when using a standard ilioinguinal approach and the new pararectus approach when treating acetabular fractures surgically. All acetabular fractures that underwent fixation using either approach between February 2005 and September 2014 were retrospectively reviewed and the demographics of the patients, the surgical details and complications were recorded.

A total of 100 patients (69 men, 31 women; mean age 57 years, 18 to 93) who were consecutively treated were included for analysis. The quality of reduction was assessed using standardised measurement of the gaps and steps in the articular surface on pre- and post-operative CT-scans.

There were no significant differences in the demographics of the patients, the surgical details or the complications between the two approaches. A significantly better reduction of the gap, however, was achieved with the pararectus approach (axial: p = 0.025, coronal: p = 0.013, sagittal: p = 0.001).

These data suggest that the pararectus approach is at least equal to, or in the case of reduction of the articular gap, superior to the ilioinguinal approach.

This approach allows direct buttressing of the dome of the acetabulum and the quadrilateral plate, which is particularly favourable in geriatric fracture patterns.

Cite this article: Bone Joint J 2015;97-B:1271-8.


The Bone & Joint Journal
Vol. 99-B, Issue 11 | Pages 1450 - 1457
1 Nov 2017
vanWinterswijk PJTS Whitehouse SL Timperley AJ Hubble MJW Howell JR Wilson MJ

Aims

We report the incidence of radiolucent lines (RLLs) using two flanged acetabular components at total hip arthroplasty (THA) and the effect of the Rim Cutter.

Patients and Methods

We performed a retrospective review of 300 hips in 292 patients who underwent primary cemented THA. A contemporary flanged acetabular component was used with (group 1) and without (group 2) the use of the Rim Cutter and the Rimfit acetabular component was used with the Rim Cutter (group 3). RLLs and clinical outcomes were evaluated immediately post-operatively and at five years post-operatively.


Bone & Joint 360
Vol. 6, Issue 6 | Pages 2 - 10
1 Dec 2017
Luokkala T Watts AC


Bone & Joint 360
Vol. 6, Issue 4 | Pages 20 - 22
1 Aug 2017