Advertisement for orthosearch.org.uk
Results 141 - 160 of 168
Results per page:
Bone & Joint 360
Vol. 4, Issue 6 | Pages 1 - 1
1 Dec 2015
Ollivere B


Bone & Joint 360
Vol. 3, Issue 4 | Pages 35 - 38
1 Aug 2014
Hammerberg EM


The Bone & Joint Journal
Vol. 96-B, Issue 7 | Pages 963 - 969
1 Jul 2014
Mellstrand-Navarro C Pettersson HJ Tornqvist H Ponzer S

The aim of this study was to investigate the epidemiology of fractures of the distal radius in the Swedish population and to review the methods used to treat them between 2005 and 2010.

The study population consisted of every patient in Sweden who was diagnosed with a fracture of the wrist between 1 January 2005 and 31 December 2010. There were 177 893 fractures of the distal radius. The incidence rate in the total population was 32 per 10 000 person-years. The mean age of the patients was 44 years (0 to 104). The proportion of fractures treated operatively increased from 16% in 2005 to 20% in 2010. The incidence rate for plate fixation in the adult population increased 3.61 fold. The incidence rate for external fixation decreased by 67%. The change was greatest in the 50 years to 74 years age group.

In Sweden, there is an increasing tendency to operate on fractures of the distal radius. The previously reported increase in the use of plating is confirmed: it has increased more than threefold over a five-year period.

Cite this article: Bone Joint J 2014;96-B:963–9.


Bone & Joint 360
Vol. 4, Issue 4 | Pages 1 - 1
1 Aug 2015
Ollivere B


Bone & Joint Research
Vol. 5, Issue 4 | Pages 153 - 161
1 Apr 2016
Kleinlugtenbelt YV Nienhuis RW Bhandari M Goslings JC Poolman RW Scholtes VAB

Objectives

Patient-reported outcome measures (PROMs) are often used to evaluate the outcome of treatment in patients with distal radial fractures. Which PROM to select is often based on assessment of measurement properties, such as validity and reliability. Measurement properties are assessed in clinimetric studies, and results are often reviewed without considering the methodological quality of these studies. Our aim was to systematically review the methodological quality of clinimetric studies that evaluated measurement properties of PROMs used in patients with distal radial fractures, and to make recommendations for the selection of PROMs based on the level of evidence of each individual measurement property.

Methods

A systematic literature search was performed in PubMed, EMbase, CINAHL and PsycINFO databases to identify relevant clinimetric studies. Two reviewers independently assessed the methodological quality of the studies on measurement properties, using the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) checklist. Level of evidence (strong / moderate / limited / lacking) for each measurement property per PROM was determined by combining the methodological quality and the results of the different clinimetric studies.


Bone & Joint 360
Vol. 4, Issue 5 | Pages 22 - 24
1 Oct 2015

The October 2015 Trauma Roundup360 looks at: PCA not the best in resuscitation; Impact of trauma centre care; Quality of life after a hip fracture; Recovery and severity of injury: open tibial fractures in the spotlight; Assessment of the triplane fractures; Signs of an unstable paediatric pelvis; Safe insertion of SI screws: are two views required?; Post-operative delirium under the spotlight; Psychological effects of fractures; K-wires cost effective in DRAFFT


Bone & Joint Research
Vol. 4, Issue 5 | Pages 78 - 83
1 May 2015
Martinkevich P Rahbek O Møller-Madsen B Søballe K Stilling M

Objectives

Lengthening osteotomies of the calcaneus in children are in general grafted with bone from the iliac crest. Artificial bone grafts have been introduced, however, their structural and clinical durability has not been documented. Radiostereometric analysis (RSA) is a very accurate and precise method for measurements of rigid body movements including the evaluation of joint implant and fracture stability, however, RSA has not previously been used in clinical studies of calcaneal osteotomies. We assessed the precision of RSA as a measurement tool in a lateral calcaneal lengthening osteotomy (LCLO).

Methods

LCLO was performed in six fixed adult cadaver feet. Tantalum markers were inserted on each side of the osteotomy and in the cuboideum. Lengthening was done with a plexiglas wedge. A total of 24 radiological double examinations were obtained. Two feet were excluded due to loose and poorly dispersed markers. Precision was assessed as systematic bias and 95% repeatability limits.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 8 | Pages 1055 - 1058
1 Aug 2008
Lee HS Kim JS Park S Lee D Park JM Wapner KL

We studied 11 patients with checkrein deformities of the hallux who underwent surgical treatment. Six had lengthening of the flexor hallucis longus tendon by Z-plasty in the midfoot, and five underwent release of adhesions and lengthening of the tendon by Z-plasty at the musculotendinous junction at the fracture site.

All six patients who underwent Z-plasty at the midfoot showed complete correction of the deformity without recurrence. Of the five who had release of adhesions and Z-plasty of the tendon at the fracture site, two showed partial and one showed complete recurrence.


The Bone & Joint Journal
Vol. 96-B, Issue 11_Supple_A | Pages 48 - 55
1 Nov 2014
Yasen AT Haddad FS

We are currently facing an epidemic of periprosthetic fractures around the hip. They may occur either during surgery or post-operatively. Although the acetabulum may be involved, the femur is most commonly affected. We are being presented with new, difficult fracture patterns around cemented and cementless implants, and we face the challenge of an elderly population who may have grossly deficient bone and may struggle to rehabilitate after such injuries. The correct surgical management of these fractures is challenging. This article will review the current choices of implants and techniques available to deal with periprosthetic fractures of the femur.

Cite this article: Bone Joint J 2014;96-B(11 Suppl A):48–55.


Bone & Joint 360
Vol. 2, Issue 3 | Pages 31 - 33
1 Jun 2013

The June 2013 Trauma Roundup360 looks at: open foot fractures; the diagnostic accuracy of continuous compartment pressure monitoring; conservative treatment for supracondylar fractures; high complication rates in patellar fractures; vitamin D and fracture; better function with K-wires; and tensionless bands.


The Bone & Joint Journal
Vol. 95-B, Issue 6 | Pages 825 - 830
1 Jun 2013
Abram SGF Pollard TCB Andrade AJMD

The Gamma nail is frequently used in unstable peri-trochanteric hip fractures. We hypothesised that mechanical failure of the Gamma nail was associated with inadequate proximal three-point fixation. We identified a consecutive series of 299 Gamma nails implanted in 299 patients over a five-year period, 223 of whom fulfilled our inclusion criteria for investigation. The series included 61 men and 162 women with a mean age of 81 years (20 to 101). Their fractures were classified according to the Modified Evans’ classification and the quality of fracture reduction was graded. The technical adequacy of three points of proximal fixation was recorded from intra-operative fluoroscopic images, and technical inadequacy for each point was defined. All patients were followed to final follow-up and mechanical failures were identified. A multivariate statistical analysis was performed, adjusting for confounders. A total of 16 failures (7.2%) were identified. The position of the lag screw relative to the lateral cortex was the most important point of proximal fixation, and when inadequate the failure rate was 25.8% (eight of 31: odds ratio 7.5 (95% confidence interval 2.5 to 22.7), p < 0.001).

Mechanical failure of the Gamma nail in peri-trochanteric femoral fractures is rare (< 1%) when three-point proximal fixation is achieved. However, when proximal fixation is inadequate, failure rates increase. The strongest predictor of failure is positioning the lateral end of the lag screw short of the lateral cortex. Adherence to simple technical points minimises the risk of fixation failure in this vulnerable patient group.

Cite this article: Bone Joint J 2013;95-B:825–30.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 12 | Pages 1591 - 1594
1 Dec 2012
Cousins GR Obolensky L McAllen C Acharya V Beebeejaun A

We report the results of six trauma and orthopaedic projects to Kenya in the last three years. The aims are to deliver both a trauma service and teaching within two hospitals; one a district hospital near Mount Kenya in Nanyuki, the other the largest public hospital in Kenya in Mombasa. The Kenya Orthopaedic Project team consists of a wide range of multidisciplinary professionals that allows the experience to be shared across those specialties. A follow-up clinic is held three months after each mission to review the patients. To our knowledge there are no reported outcomes in the literature for similar projects.

A total of 211 operations have been performed and 400 patients seen during the projects. Most cases were fractures of the lower limb; we have been able to follow up 163 patients (77%) who underwent surgical treatment. We reflect on the results so far and discuss potential improvements for future missions.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 8 | Pages 1143 - 1144
1 Aug 2011
Khanduja V


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 11 | Pages 1433 - 1439
1 Nov 2011
Dias JJ Singh HP

A displaced fracture of the scaphoid is one in which the fragments have moved from their anatomical position or there is movement between them when stressed by physiological loads. Displacement is seen in about 20% of fractures of the waist of the scaphoid, as shown by translation, a gap, angulation or rotation. A CT scan in the true longitudinal axis of the scaphoid demonstrates the shape of the bone and displacement of the fracture more accurately than do plain radiographs. Displaced fractures can be treated in a plaster cast, accepting the risk of malunion and nonunion. Surgically the displacement can be reduced, checked radiologically, arthroscopically or visually, and stabilised with headless screws or wires. However, rates of union and deformity are unknown. Mild malunion is well tolerated, but the long-term outcome of a displaced fracture that healed in malalignment has not been established.

This paper summarises aspects of the assessment, treatment and outcome of displaced fractures of the waist of the scaphoid.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 7 | Pages 984 - 988
1 Jul 2010
Guo JJ Tang N Yang HL Tang TS

We compared the outcome of closed intramedullary nailing with minimally invasive plate osteosynthesis using a percutaneous locked compression plate in patients with a distal metaphyseal fracture in a prospective study.

A total of 85 patients were randomised to operative stabilisation either by a closed intramedullary nail (44) or by minimally invasive osteosynthesis with a compression plate (41). Pre-operative variables included the patients’ age and the side and pattern of the fracture. Peri-operative variables were the operating time and the radiation time. Postoperative variables were wound problems, the time to union of the fracture, the functional American Orthopaedic Foot and Ankle surgery score and removal of hardware.

We found no significant difference in the pre-operative variables or in the time to union in the two groups. However, the mean radiation time and operating time were significantly longer in the locked compression plate group (3.0 vs 2.12 minutes, p < 0.001, and 97.9 vs 81.2 minutes, p < 0.001, respectively). After one year, all the fractures had united. Patients who had intramedullary nailing had a higher mean pain score, but better function, alignment and total American Orthopaedic Foot and Ankle surgery scores, although the differences were not statistically significant (p = 0.234, p = 0.157, p = 0.897, p = 0.177 respectively). Three (6.8%) patients in the intramedullary nailing group and six (14.6%) in the locked compression plate group showed delayed wound healing, and 37 (84.1%) in the former group and 38 (92.7%) in the latter group expressed a wish to have the implant removed.

We conclude that both closed intramedullary nailing and a percutaneous locked compression plate can be used safely to treat Orthopaedic Trauma Association type-43A distal metaphyseal fractures of the tibia. However, closed intramedullary nailing has the advantage of a shorter operating and radiation time and easier removal of the implant. We therefore prefer closed intramedullary nailing for patients with these fractures.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 12 | Pages 1625 - 1628
1 Dec 2006
Livani B Belangero WD Castro de Medeiros R

Fractures of the distal third of the humerus may be complicated by complete lesions of the radial nerve which may be entrapped or compressed by bone fragments. Indirect reduction and internal fixation may result in a permanent nerve lesion.

We describe the treatment of these lesions by insertion of a bridge plate using the minimally-invasive percutaneous technique. Six patients were operated on and showed complete functional recovery. Healing of the fractures occurred at a mean of 2.7 months (2 to 3) and complete neurological recovery by a mean of 2.3 months (1 to 5). In one patient infection occurred which resolved after removal of the implant.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 3 | Pages 304 - 309
1 Mar 2009
Kerboull L Hamadouche M Kerboull M

We describe 129 consecutive revision total hip replacements using a Charnley-Kerboull femoral component of standard length with impaction allografting. The mean follow-up was 8.2 years (2 to 16). Additionally, extramedullary reinforcement was performed using struts of cortical allograft in 49 hips and cerclage wires in 30.

There was one intra-operative fracture of the femur but none later. Two femoral components subsided by 5 mm and 8 mm respectively, and were considered to be radiological failures. No further revision of a femoral component was required. The rate of survival of the femoral component at nine years, using radiological failure as the endpoint, was 98%. Our study showed that impaction grafting in association with a Charnley-Kerboull femoral component has a low rate of subsidence. Reconstruction of deficiencies of distal bone with struts of cortical allograft appeared to be an efficient way of preventing postoperative femoral fracture for up to 16 years.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 10 | Pages 1271 - 1275
1 Oct 2008
Downing ND Karantana A

The recent development of locking-plate technology has led to a potential revolution in the management of fractures of the distal radius. This review examines the evidence for pursuing anatomical restoration of the distal radius and the possible advantages and pitfalls of using volar locking plates to achieve this goal. The available evidence for adopting volar locking plates is presented and a number of important and, as yet unanswered, questions are highlighted.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 4 | Pages 568 - 570
1 Apr 2005
Muller SD Al-Maiyah M Hui AC Adedapo AO

We describe a patient who sustained a widely displaced, high-energy, mid-shaft clavicular fracture in association with brachial plexus damage. The distal fragment was subsequently found to have penetrated the thoracic cavity. We describe the treatment of this rare injury with a successful outcome.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 2 | Pages 236 - 239
1 Feb 2007
van Geenen RCI Besselaar PP

We analysed the operative technique, morbidity and functional outcome of osteotomy and plate fixation for malunited fractures of the forearm sustained in childhood.

A total of 20 consecutive patients underwent corrective osteotomy of 21 malunited fractures at a mean age of 12 years (4 to 25). The mean time between the injury and the osteotomy was 30 months (2 to 140).

After removal of the plate, one patient suffered transient dysaesthesia of the superficial radial nerve. The mean gain in the range of movement was 85° (20° to 140°). The interval between injury and osteotomy, and the age at osteotomy significantly influenced the functional outcome (p = 0.011 and p = 0.004, respectively).

Malunited fractures of the forearm sustained in childhood can be adequately treated by osteotomy and plate fixation with excellent functional results and minimal complications. In the case of established malunion it is advisable to perform corrective osteotomy without delay.