We investigated 219 revisions of total hip replacement (THR) in 211 patients using a collarless double-taper
We have assessed the long-term results of 292
We examined radiographic polyethylene wear in 233
Objectives. Third-body wear is believed to be one trigger for adverse results
with metal-on-metal (MOM) bearings. Impingement and subluxation
may release metal particles from MOM replacements. We therefore
challenged MOM bearings with relevant debris types of cobalt–chrome
alloy (CoCr), titanium alloy (Ti6Al4V) and polymethylmethacrylate
bone
There are no long-term published results on the survival of a third-generation
We performed a case–control study to compare
the rates of further surgery, revision and complications, operating time
and survival in patients who were treated with either an uncemented
hydroxyapatite-coated Corail bipolar femoral stem or a cemented
Exeter stem for a displaced intracapsular fracture of the hip. The
mean age of the patients in the uncemented group was 82.5 years
(53 to 97) and in the
We retrospectively studied local recurrence of giant cell tumour in long bones following treatment with curettage and
Bone mineral density (BMD) around the femoral component has been reported to decrease after total knee replacement (TKR) because of stress shielding. Our aim was to determine whether a
Concerns have been reported to the United Kingdom
National Patient Safety Agency, warning that
We undertook a multicentre, prospective study of a series of 112 unstable trochanteric fractures in order to evaluate if internal fixation with a sliding screw device combined with augmentation using a calcium phosphate degradable
Bone
We used a rat model in vivo to study the effects of particulate bone
Conventional
We used 99 strains of organisms representative of orthopaedic infections to examine the effectiveness of a bone
Early implants for total knee replacement were fixed to bone with
Intramedullary infection in long bones represents
a complex clinical challenge, with an increasing incidence due to the
increasing use of intramedullary fixation. We report a prospective
case series using an intramedullary reaming device, the Reamer–Irrigator–Aspirator
(RIA) system, in association with antibiotic
Failure of total hip arthroplasty with acetabular deficiency occurred in 55 patients (60 hips) and was treated with acetabular revision using morsellised allograft and a
We matched 78 patients with a loose
Previous studies have shown that the activity of the cytostatic drug methotrexate (MTX) embedded in acrylic cement is not affected by thermal changes in the
A heavy infiltrate of foreign-body macrophages is commonly seen in the fibrous membrane which surrounds an aseptically loose