We measured the tension in the interosseous membrane
in six cadaveric forearms using an Cite this article:
This prospective study evaluates the role of new laboratory markers in the diagnosis of deep implant infection in 78 patients (41 men and 37 women) with a revision total knee or hip replacement. The mean age at the time of operation was 64.0 years (19 to 90). Intra-operative cultures showed that 21 patients had a septic and 57 an aseptic total joint replacement. The white blood cell count, the erythrocyte sedimentation rate and levels of C-reactive protein, interleukin-6, procalcitonin and tumour necrosis factor (TNF)-α were measured in blood samples before operation. The diagnostic cut-off values were determined by Received Operating Characteristic curve analysis. C-reactive protein (>
3.2 md/dl) and interleukin-6 (>
12 pg/ml) have the highest sensitivity (0.95). Interleukin-6 is less specific than C-reactive protein (0.87 The combination of C-reactive protein and interleukin-6 measurement provide excellent screening tests for infection of a deep implant. A highly specific marker such as procalcitonin and pre-operative aspiration of the joint might be useful in identifying patients with true positive C-reactive protein and/or interleukin-6 levels.
To study the measurement properties of a joint specific patient
reported outcome measure, a measure of capability and a general
health-related quality of life (HRQOL) tool in a large cohort of
patients with a hip fracture. Responsiveness and associations between the Oxford Hip Score
(a hip specific measure: OHS), ICEpop CAPability (a measure of capability
in older people: ICECAP-O) and EuroQol EQ-5D (general health-related
quality of life measure: EQ-5D) were assessed using data available
from two large prospective studies. The three outcome measures were assessed
concurrently at a number of fixed follow-up time-points in a consecutive
sequence of patients, allowing direct assessment of change from
baseline, inter-measure associations and validity using a range
of statistical methods.Objectives
Methods
Slipped capital femoral epiphysis (SCFE) is uncommon
in India and we routinely look for associated metabolic or endocrine
abnormalities. In this study we investigated a possible association
between vitamin D deficiency and SCFE. All children presenting with
SCFE during the study period had their 25-hydroxyvitamin D levels
measured as part of an overall metabolic, renal and endocrine status
evaluation, which included measurement of body mass index (BMI).
Vitamin D status was compared with age-, gender- and habitat-matched
controls with acute trauma or sepsis presenting to our emergency
department. A total of 15 children (12 boys and three girls) with a mean
age of 13 years ( Cite this article:
Several factors have been implicated in unsatisfactory
results after total hip replacement (THR). We examined whether femoral
offset, as measured on digitised post-operative radiographs, was
associated with pain after THR. The routine post-operative radiographs
of 362 patients (230 women and 132 men, mean age 70.0 years (35.2
to 90.5)) who received primary unilateral THRs of varying designs
were measured after calibration. The femoral offset was calculated
using the known dimensions of the implants to control for femoral
rotation. Femoral offset was categorised into three groups: normal
offset (within 5 mm of the height-adjusted femoral offset), low
offset and high offset. We determined the associations to the absolute
final score and the improvement in the mean Western Ontario and
McMaster Universities osteoarthritis index (WOMAC) pain subscale
scores at three, six, 12 and 24 months, adjusting for confounding
variables. The amount of femoral offset was associated with the mean WOMAC
pain subscale score at all points of follow-up, with the low-offset
group reporting less WOMAC pain than the normal or high-offset groups
(six months: 7.01 ( Cite this article:
The treatment of fractures of the proximal tibia is complex and makes great demands on the implants used. Our study aimed to identify what levels of primary stability could be achieved with various forms of osteosynthesis in the treatment of diaphyseal fractures of the proximal tibia. Pairs of human tibiae were investigated. An unstable fracture was simulated by creating a defect at the metaphyseal-diaphyseal junction. Six implants were tested in a uniaxial testing device (Instron) using the quasi-static and displacement-controlled modes and the force-displacement curve was recorded. The movements of each fragment and of the implant were recorded video-optically (MacReflex, Qualysis). Axial deviations were evaluated at 300 N. The results show that the nailing systems tolerated the highest forces. The lowest axial deviations in varus and valgus were also found for the nailing systems; the highest axial deviations were recorded for the buttress plate and the less invasive stabilising system (LISS). In terms of rotational displacement the LISS was better than the buttress plate. In summary, it was found that higher loads were better tolerated by centrally placed load carriers than by eccentrically placed ones. In the case of the latter, it appears advantageous to use additive procedures for medial buttressing in the early phase.
We studied 33 third generation, alumina ceramic-on-ceramic bearings retrieved from cementless total hip replacements after more than six months in situ. Wear volume was measured with a Roundtest machine, and acetabular orientation from the anteroposterior pelvic radiograph. The overall median early wear rate was 0.1 mm3/yr for the femoral heads, and 0.04 mm3/yr for the acetabular liners. We then excluded hips where the components had migrated. In this stable subgroup of 22 bearings, those with an acetabular anteversion of <
15° (seven femoral heads) had a median femoral head wear rate of 1.2 mm3/yr, compared with 0 mm3/yr for those with an anteversion of ≥15° (15 femoral heads, p <
0.001). Even under edge loading, wear volumes with ceramic-on-ceramic bearings are small in comparison to other bearing materials. Low acetabular anteversion is associated with greater wear.
We evaluated the concentrations of chromium and cobalt ions in blood after metal-on-metal surface replacement arthroplasty using a wrought-forged, high carbon content chromium-cobalt alloy implant in 64 patients. At one year, mean whole blood ion levels were 1.61 μg/L (0.4 to 5.5) for chromium and 0.67 μg/L (0.23 to 2.09) for cobalt. The pre-operative ion levels, component size, female gender and the inclination of the acetabular component were inversely proportional to the values of chromium and/or cobalt ions at one year postoperatively. Other factors, such as age and level of activity, did not correlate with the levels of metal ions. We found that the levels of the ions in the serum were 1.39 and 1.37 times higher for chromium and cobalt respectively than those in the whole blood. The levels of metal ions obtained may be specific to the hip resurfacing implant and reflect its manufacturing process.
Fractures of the distal radius occurring in young adults are treated increasingly by open surgical techniques, partly because of concern that failure to restore the alignment of the fracture accurately may cause symptomatic post-traumatic osteoarthritis in future years. We reviewed 106 adults who had sustained a fracture of the distal radius between 1960 and 1968 and who were below the age of 40 years at the time of injury. We carried out a clinical and radiological assessment at a mean follow-up of 38 years (33 to 42). No patient had required a salvage procedure. While there was radiological evidence of post-traumatic osteoarthritis after an intra-articular fracture in 68% of patients (27 of 40), the disabilities of the arm, shoulder and hand (DASH) scores were not different from population norms, and function, as assessed by the Patient Evaluation Measure, was impaired by less than 10%. Ordinal logistic regression analysis showed a significant relationship between narrowing of the joint space and extra-articular malunion (dorsal angulation and radial shortening) as well as intra-articular injury. Multivariate analysis revealed that grip strength had fallen to 89% of that of the uninjured side in the presence of dorsal malunion, but no measure of extra-articular malunion was significantly related to either the Patient Evaluation Measure or DASH scores. While anatomical reduction is the principal aim of treatment, imperfect reduction of these fractures may not result in symptomatic arthritis in the long term, and this should be considered when counselling patients on the risks and benefits of the many treatment options available.
The glenopolar angle assesses the rotational
alignment of the glenoid and may provide prognostic information
and aid the management of scapula fractures. We have analysed the
effect of the anteroposterior (AP) shoulder radiograph rotational
offset on the glenopolar angle in a laboratory setting and used
this to assess the accuracy of shoulder imaging employed in routine
clinical practice. Fluoroscopic imaging was performed on 25 non-paired scapulae
tagged with 2 mm steel spheres to determine the orientation of true
AP views. The glenopolar angle was measured on all the bony specimens
rotated at 10° increments. The mean glenopolar angle measured on
the bone specimens in rotations between 0° and 20° and thereafter
was found to be significantly different (p <
0.001). We also obtained
the AP radiographs of the uninjured shoulder of 30 patients treated
for fractures at our centre and found that none fitted the criteria
of a true AP shoulder radiograph. The mean angular offset from the
true AP view was 38° (10° to 65°) for this cohort. Radiological
AP shoulder views may not fully project the normal anatomy of the scapular
body and the measured glenopolar angle. The absence of a true AP
view may compromise the clinical management of a scapular fracture. Cite this article:
Ensuring correct rotation of the femoral component
is a challenging aspect of patellofemoral replacement surgery. Rotation
equal to the epicondylar axis or marginally more external rotation
is acceptable. Internal rotation is associated with poor outcomes.
This paper comprises two studies evaluating the use of the medial
malleolus as a landmark to guide rotation. We used 100 lower-leg anteroposterior radiographs to evaluate
the reliability of the medial malleolus as a landmark. Assessment
was made of the angle between the tibial shaft and a line from the
intramedullary rod entry site to the medial malleolus. The femoral
cut was made in ten cadaver knees using the inferior tip of the
medial malleolus as a landmark for rotation. Rotation of the cut
relative to the anatomical epicondylar axis was assessed using CT.
The study of radiographs found the position of the medial malleolus
relative to the tibial axis is consistent. Using the inferior tip
of the medial malleolus in the cadaver study produced a mean external
rotation of 1.6° (0.1° to 3.7°) from the anatomical epicondylar
axis. Using the inferior tip of the medial malleolus to guide the
femoral cutting jig avoids internal rotation and introduces an acceptable
amount of external rotation of the femoral component.
Our understanding of the origin of hip pain in
degenerative disorders of the hip, including primary osteoarthritis, avascular
necrosis and femoroacetabular impingement (FAI), is limited. We
undertook a histological investigation of the nociceptive innervation
of the acetabular labrum, ligamentum teres and capsule of the hip,
in order to prove pain- and proprioceptive-associated marker expression.
These structures were isolated from 57 patients who had undergone
elective hip surgery (44 labral samples, 33 ligamentum teres specimens,
34 capsular samples; in 19 patients all three structures were harvested).
A total of
15 000 histological sections were prepared that were investigated
immunohistochemically for the presence of protein S-100, 68 kDa
neurofilament, neuropeptide Y, nociceptin and substance P. The tissues
were evaluated in six representative areas. Within the labrum, pain-associated free nerve ending expression
was located predominantly at its base, decreasing in the periphery.
In contrast, the distribution within the ligamentum teres showed
a high local concentration in the centre. The hip capsule had an
almost homogeneous marker expression in all investigated areas. This study showed characteristic distribution profiles of nociceptive
and pain-related nerve fibres, which may help in understanding the
origin of hip pain. Cite this article:
We compared the accuracy of the growth remaining
method of assessing leg-length discrepancy (LLD) with the straight-line
graph method, the multiplier method and their variants. We retrospectively
reviewed the records of 44 patients treated by percutaneous epiphysiodesis
for LLD. All were followed up until maturity. We used the modified Green–Anderson
growth-remaining method (Method 1) to plan the timing of epiphysiodesis.
Then we presumed that the other four methods described below were
used pre-operatively for calculating the timing of epiphysiodesis. We
then assumed that these four methods were used pre-operatively.
Method 2 was the original Green–Anderson growth-remaining method;
Method 3, Paley’s multiplier method using bone age; Method 4, Paley’s
multiplier method using chronological age; and Method 5, Moseley’s
straight-line graph method. We compared ‘Expected LLD at maturity
with surgery’ with ‘Final LLD at maturity with surgery’ for each
method. Statistical analysis revealed that ‘Expected LLD at maturity
with surgery’ was significantly different from ‘Final LLD at maturity
with surgery’. Method 2 was the most accurate. There was a significant
correlation between ‘Expected LLD at maturity with surgery’ and
‘Final LLD at maturity with surgery’, the greatest correlation being
with Method 2. Generally all the methods generated an overcorrected
value. No method generates the precise ‘Expected LLD at maturity
with surgery’. It is essential that an analysis of the pattern of
growth is taken into account when predicting final LLD. As many
additional data as possible are required. Cite this article:
The aim of this study was to determine the association
between the Oxford knee score (OKS) and direct assessment of outcome,
and to examine how this relationship varied at different time-points
following total knee replacement (TKR). Prospective data consisting
of the OKS, numerical rating scales for ‘worst pain’ and ‘perceived
mean daily pain’, timed functional assessments (chair rising, stairs
and walking ability), goniometry and lower limb power were recorded
for 183 patients pre-operatively and at six, 26 and 52 weeks post-operatively.
The OKS was influenced primarily by the patient’s level of pain
rather than objective functional assessments. The relationship between report
of outcome and direct assessment changed over time: R2 =
35% pre-operatively, 44% at six weeks, 57% at 26 weeks and 62% at
52 weeks. The relationship between assessment of performance and report
of performance improved as the patient’s report of pain diminished,
suggesting that patients’ reporting of functional outcome after
TKR is influenced more by their pain level than their ability to
accomplish tasks.
Eighteen hip fusions were converted to total
hip replacements. A constrained acetabular liner was used in three hips.
Mean follow up was five years (two to 15). Two (11%) hips failed,
requiring revision surgery and two patients (11%) had injury to
the peroneal nerve. Heterotopic ossification developed in seven
(39%) hips, in one case resulting in joint ankylosis. No hips dislocated. Conversion of hip fusion to hip replacement carries an increased
risk of heterotopic ossification and neurological injury. We advise
prophylaxis against heterotropic ossification. When there is concern
about hip stability we suggest that the use of a constrained acetabular
liner is considered. Despite the potential for complications, this procedure
had a high success rate and was effective in restoring hip function.
We present the electromyographic (EMG) results
ten years after open decompression of the median nerve at the wrist
and compare them with the clinical and functional outcomes as judged
by Levine’s Questionnaire. This retrospective study evaluated 115
patients who had undergone carpal tunnel decompression at a mean
of 10.47 years (9.24 to 11.36) previously. A positive EMG diagnosis
was found in 77 patients (67%), including those who were asymptomatic
at ten years. It is necessary to include both clinical and functional results
as well as electromyographic testing in the long-term evaluation
of patients who have undergone carpal tunnel decompression particularly
in those in whom revision surgery is being considered. In doubtful
cases or when there are differing outcomes, self-administered scales
such as Levine’s Questionnaire should prevail over EMG results when
deciding on the need for revision surgery.
Deformity after slipped upper femoral epiphysis
(SUFE) can cause cam-type femoroacetabular impingement (FAI) and
subsequent osteoarthritis (OA). However, there is little information
regarding the radiological assessment and clinical consequences
at long-term follow-up. We reviewed 36 patients (43 hips) previously
treated by We conclude that persistent deformity with radiological cam FAI
after SUFE is associated with poorer clinical and radiological long-term
outcome. Although the radiological measurements had quite wide limits
of agreement, they are useful for the diagnosis of post-slip deformities
in clinical practice.
In a double-blinded randomised controlled trial,
83 patients with primary osteoarthritis of the hip received either
a ceramic-on-metal (CoM) or metal-on-metal (MoM) total hip replacement
(THR). The implants differed only in the bearing surfaces used.
The serum levels of cobalt and chromium and functional outcome scores
were compared pre-operatively and at six and 12 months post-operatively. Data were available for 41 CoM and 36 MoM THRs (four patients
were lost to follow-up, two received incorrect implants). The baseline
characteristics of both cohorts were similar. Femoral head size
measured 36 mm in all but two patients who had 28 mm heads. The
mean serum cobalt and chromium levels increased in both groups,
with no difference noted between groups at six months (cobalt p
= 0.67, chromium p = 0.87) and 12 months (cobalt p = 0.76, chromium
p = 0.76) post-operatively. Similarly, the mean Oxford hip scores,
Western Ontario and McMaster Universities Osteoarthritis index and
University of California, Los Angeles activity scores showed comparable improvement
at 12 months. Our findings indicate that CoM and MoM couplings are associated
with an equivalent increase in serum cobalt and chromium levels,
and comparable functional outcome scores at six and 12-months follow-up.
The aim of this retrospective cohort study was
to identify any difference in femoral offset as measured on pre-operative
anteroposterior (AP) radiographs of the pelvis, AP radiographs of
the hip and corresponding CT scans in a consecutive series of 100
patients with primary end-stage osteoarthritis of the hip (43 men
and 57 women with a mean age of 61 years (45 to 74) and a mean body
mass index of 28 kg/m2 (20 to 45)). Patients were positioned according to a standardised protocol
to achieve reproducible projection and all images were calibrated.
Inter- and intra-observer reliability was evaluated and agreement
between methods was assessed using Bland-Altman plots. In the entire cohort, the mean femoral offset was 39.0 mm (95%
confidence interval (CI) 37.4 to 40.6) on radiographs of the pelvis,
44.0 mm (95% CI 42.4 to 45.6) on radiographs of the hip and 44.7
mm (95% CI 43.5 to 45.9) on CT scans. AP radiographs of the pelvis
underestimated femoral offset by 13% when compared with CT (p <
0.001).
No difference in mean femoral offset was seen between AP radiographs
of the hip and CT (p = 0.191). Our results suggest that femoral offset is significantly underestimated
on AP radiographs of the pelvis but can be reliably and accurately
assessed on AP radiographs of the hip in patients with primary end-stage
hip osteoarthritis. We, therefore, recommend that additional AP radiographs of the
hip are obtained routinely for the pre-operative assessment of femoral
offset when templating before total hip replacement.
In patients with osteoporosis there is always
a strong possibility that pedicle screws will loosen. This makes
it difficult to select the appropriate osteoporotic patient for
a spinal fusion. The purpose of this study was to determine the
correlation between bone mineral density (BMD) and the magnitude
of torque required to insert a pedicle screw. To accomplish this,
181 patients with degenerative disease of the lumbar spine were
studied prospectively. Each underwent dual-energy x-ray absorptiometry
(DEXA) and intra-operative measurement of the torque required to
insert each pedicle screw. The levels of torque generated in patients
with osteoporosis and osteopenia were significantly lower than those
achieved in normal patients. Positive correlations were observed between
BMD and T-value at the instrumented lumbar vertebrae, mean BMD and
mean T-value of the lumbar vertebrae, and mean BMD and mean T-value
of the proximal femur. The predictive torque (Nm) generated during pedicle
screw insertion was [-0.127 + 1.62 × (BMD at the corresponding lumbar
vertebrae)], as measured by linear regression analysis. The positive
correlation between BMD and the maximum torque required to insert
a pedicle screw suggests that pre-operative assessment of BMD may
be useful in determining the ultimate strength of fixation of a
device, as well as the number of levels that need to be fixed with
pedicle screws in patients who are suspected of having osteoporosis.