Advertisement for orthosearch.org.uk
Results 141 - 160 of 3667
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 63-B, Issue 1 | Pages 120 - 125
1 Feb 1981
Sazbon L Najenson T Tartakovsky M Becker E Grosswasser Z

Widespread periarticular new-bone formation (myositis ossificans) was studied in 45 patients with brain damage who were in long-term coma. Thirty-six of these patients displayed myositis ossificans around at least one major joint. The development of myositis ossificans was shown to be independent of the sex and age of the patient and also of the aetiology, duration and outcome of the coma. Radiographic evidence first appeared between one and two months after the onset of coma. The maximal spread of myositis ossificans was reached in the first five months after the onset of coma. Progression of the disease was not observed after 14 months. Myositis ossificans was defined as a progressive self-limiting disease found in comatose patients


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 4 | Pages 616 - 623
1 Jul 1993
Joshi A Porter M Trail I Hunt L Murphy J Hardinge K

We report the long-term outcome of 218 Charnley low-friction arthroplasties in 141 patients who were 40 years old or younger at the time of surgery. The minimum follow-up was ten years with a mean of 16 years. The probability of the femoral component surviving 20 years was 86% and of the acetabular component, 84%. The chance that both components would survive for this period was 75%. The pathological diagnosis significantly influenced implant survival. In rheumatoid patients the probability of both components surviving at 20 years was 96% compared with 51% in patients with osteoarthritis. Clinical assessment of 103 patients (166 hips) in whom the arthroplasty was still functioning showed that 94% of hips had minimal pain or none. We conclude that in young patients cemented total hip replacement is a good procedure for those with rheumatoid arthritis but that the results are much less reliable in those with osteoarthritis


The Journal of Bone & Joint Surgery British Volume
Vol. 59-B, Issue 3 | Pages 352 - 354
1 Aug 1977
Wilkinson J

Thirty-one patients have been reviewed four and a half to thirteen years after total excision of the patella for fracture. This operation did not give the uniformly excellent results previously reported by some authors. The type of incision used was unimportant in the long term. Immobilisation in plaster-of-Paris for any period between one and eight weeks after operation had no adverse effect on the long-term results. There was no correlation between the amount of calcification or ectopic bone formation found in the patellar tendon and the degree of function or discomfort in the joint. There was no evidence that osteoarthritis is an inevitable sequel to patellectomy in man. Maximal recovery of knee function may take up to three years after patellectomy. In this series 22% of patients had excellent results, 39% good results and 39% poor results, according to defined criteria. The implications of these findings are discussed


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1184 - 1185
1 Oct 2019
Amstutz HC Le Duff MJ


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 1 | Pages 96 - 99
1 Jan 1991
Korkala O Tanskanen P Makijarvi J Sorvali T Ylikoski M Haapala J

We studied the late outcome of 40 ankles (from a consecutive series of 42) treated by a modified Evans procedure. The peroneus brevis tendon was used to fashion a static tenodesis. All the patients had suffered from persistent lateral instability following an ankle sprain. The follow-up period was between nine and 12 years. Excellent or good results were achieved in 33 ankles (82.5%), three had a fair result, and four were poor. The clinical results were matched by the radiographic results which showed significant talar tilt or anterior talar translation in only three ankles. The functional result showed no positive correlation with the stress-radiographic analysis. We concluded that this modification of the Evans operation gives satisfactory long-term results, which show little change from the good results at 24 to 35 months reported in an earlier paper from our department


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 1 | Pages 42 - 49
1 Jan 1995
Fairbank A Bhatia D Jinnah R Hungerford D

We have studied the long-term results of core decompression as the sole treatment for Ficat stages I, II and III ischaemic necrosis of 128 femoral heads in 90 patients. The 5-, 10- and 15-year survival rates for the three stages were respectively: stage I 100%, 96% and 90%; stage II 85%, 74% and 66%; and stage III 58%, 35% and 23%. At a mean follow-up of 11 years (4.5 to 19), 55 hips had failed (43%). No further surgery had been needed for 88% of stage-I, 72% of stage-II and 26% of stage-III hips; but despite the generally satisfactory clinical results, 56% of the hips had progressed radiographically by at least one Ficat stage. Complications of the core procedure included four fractures, all from postoperative falls, and one head perforation due to technical error. We conclude that core decompression delays the need for total hip replacement in young patients with ischaemic necrosis


The Journal of Bone & Joint Surgery British Volume
Vol. 65-B, Issue 3 | Pages 346 - 349
1 May 1983
Scotland T Galway H

A long-term review of 131 children fitted with upper limb prostheses at the Ontario Crippled Children's Centre between 1965 and 1975 is reported. There were 116 children with congenital deficiencies and 15 who had had amputations. Follow-up ranged from 7 to 17 years. A total of 42 children had abandoned their prostheses, 37 of whom had congenital deformities and five were amputees. The level of deficiency was of fundamental importance in determining whether the prosthesis would be accepted; in the forearm, the longer the stump, the more likely it was that the child would discard the prosthesis. Overall, 50 per cent of children fitted over the age of two years abandoned their prostheses compared with only 22 per cent of patients who had been fitted before the age of two years. The highest drop-out rate was at the age of 13 years when the children became more conscious of their cosmetic appearance. Suggestions for reducing the high drop-out rate in the early teens are put forward


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 1 | Pages 31 - 36
1 Jan 2009
de Jong PT de Man FHR Haverkamp D Marti RK

We report the long-term outcome of a modified second-generation cementing technique for fixation of the acetabular component of total hip replacement. An earlier report has shown the superiority of this technique assessed by improved survival compared with first-generation cementing. The acetabular preparation involved reaming only to the subchondral plate, followed by impaction of the bone in the anchorage holes. Between 1978 and 1993, 287 total hip replacements were undertaken in 244 patients with a mean age of 65.3 years (21 to 90) using a hemispherical Weber acetabular component with this modified technique for cementing and a cemented femoral component. The survival with acetabular revision for aseptic loosening as the endpoint was 99.1% (95% confidence interval 97.9 to 100 after ten years and 85.5% (95% confidence interval 74.7 to 96.2) at 20 years. Apart from contributing to a long-lasting fixation of the component, this technique also preserved bone, facilitating revision surgery when necessary


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 4 | Pages 510 - 512
1 May 2001
Gill GS Joshi AB

We analysed the long-term results with a mean follow-up of 10.2 years, of 66 total knee replacements in 42 patients with rheumatoid arthritis. In all cases the posterior cruciate ligament was retained. There were only three complications (4.5%). Revision surgery was necessary in five knees (7.6%), including one (1.5%) with infection. At the final follow-up, 75.8% of knees were rated excellent clinically. Only 15% had an excellent function score. The survival rate of the implant was 90.7% at 19 years. The clinical, radiological and survivorship analysis shows that the posterior-cruciate-retaining knee arthroplasty performs well in rheumatoid arthritis


The Journal of Bone & Joint Surgery British Volume
Vol. 53-B, Issue 4 | Pages 609 - 616
1 Nov 1971
Jackson RK

1. The results of wide laminectomy of the fifth lumbar vertebra and disc excision in 132 patients are reviewed and compared with some published results of the interlaminar operation. 2. There was no significant difference in either the immediate or the long-term results of the two operations suggesting that post-operative morbidity was not related to operative technique. 3. The incidence of post-operative back pain was found to increase with age at operation, duration of pre-operative symptoms and length of follow-up, and supported the impression that backache is predominantly a feature of the underlying degenerative process rather than the incidental operation. 4. The significance of recurrent disc lesions is discussed. Recurrence usually occurred at the previously cleared disc space and was thought to indicate incomplete degeneration of the disc at the time of the original operation. 5. The place of fusion combined with disc excision is discussed. No reliable indications for coincident fusion were found in this series. 6. The value of radiography is discussed. Plain radiographs were essential before operation to exclude other causes of backache and sciatica; otherwise they were of little value. Motion radiographs were no more helpful and myelography was used only when the level of the lesion was in doubt. 7. The risk of an acute cauda equina lesion following manipulation of a prolapsed lumbar disc is noted and the danger of manipulation, unless facilities for emergency surgery are available, is stressed


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 7 | Pages 948 - 952
1 Jul 2007
Mitchell PD Chew NS Goutos I Healy JC Lee JC Evans S Hulme A

Our aim was to determine whether abnormalities noted on MRI immediately after reduction for developmental dysplasia of the hip could predict the persistance of dysplasia and aid surgical planning. Scans of 13 hips in which acetabular dysplasia had resolved by the age of four years were compared with those of five which had required pelvic osteotomy for persisting dysplasia. The scans were analysed by two consultant musculoskeletal radiologists who were blinded to the outcome in each child. The postreduction scans highlighted a number of anatomical abnormalities secondary to developmental dysplasia of the hip, but statistical analysis showed that none were predictive of persisting acetabular dysplasia in the older child, suggesting that the factors which determine the long-term outcome were not visible on these images


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 2 | Pages 231 - 237
1 Mar 2003
Holzer G Krepler P Koschat MA Grampp S Dominkus M Kotz R

We studied the bone mineral density (BMD) of 48 long-term survivors of highly malignant osteosarcoma who had been treated according to the chemotherapy protocols of the German- Swiss-Austrian Co-operative Osteosarcoma Study Group which include high-dose methotrexate. The mean age of the patients was 31 ± 4.2 years and the mean follow-up 16 ± 2.2 years. The BMD of the lumbar spine and of the proximal femur of the non-operated side was measured by dual- energy x-ray absorptiometry. A questionnaire was given to determine life-style factors, medical history and medication. Ten patients were osteoporotic, 21 osteopenic and 17 normal according to the WHO definition. Eighteen patients suffered fractures after receiving chemotherapy and all had significantly lower levels of BMD for all the sites measured


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 3 | Pages 445 - 448
1 May 1992
Graham G Dent C

We reviewed the long-term results of the Dillwyn Evans procedure for club foot in 60 feet of 45 patients with an average age of 29 years, using four different scoring systems. The results at 12 to 38 years were compared with those of an earlier study of the same group of patients. Function was satisfactory in 68% of feet; 90% of the patients were able to perform all desired activities. Mild residual deformity was compatible with satisfactory function, and poor function was related to ankle and subtalar stiffness. Our results suggest that this procedure has a low rate of deterioration and degenerative change with time


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 5 | Pages 802 - 808
1 Sep 1996
Britton AR Murray DW Bulstrode CJ McPherson K Denham RA

We reviewed the records of the long-term outcome of 208 Charnley and 982 Stanmore total hip replacements (THR) performed by or under the supervision of one surgeon from 1973 to 1987. The Stanmore implant had a better survival rate before revision at 14 years (86% to 79%, p = 0.004), but the difference only became apparent at ten years. The later Stanmore implants did better than the early ones (97% to 92% at ten years, p = 0.005), the improvement coinciding with the introduction of a new cementing technique using a gun. Most of the Charnley implants were done before most of the Stanmore implants so that the difference between the results may in part be explained by improved methods, but this is not the complete explanation since a difference persisted for implants carried out during the same period of time. We conclude that improved techniques have reduced failure rates substantially. This improvement was much greater than that observed between these two designs of implant. Proof of the difference would require a very large randomised controlled trial over a ten-year period


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 12 | Pages 1574 - 1580
1 Dec 2007
Hallan G Lie SA Furnes O Engesaeter LB Vollset SE Havelin LI

Primary uncemented femoral stems reported to the Norwegian arthroplasty register between 1987 and 2005 were included in this prospective observational study. There were 11 516 hips (9679 patients) and 14 different designs of stem. Kaplan-Meier survival probabilities and Cox regression were used to analyse the data. With aseptic loosening as the end-point, all currently used designs performed excellently with survival of 96% to 100% at ten years. With the end-point as stem revision for any cause, the long-term results of the different designs varied from poor to excellent, with survival at 15 years ranging between 29% and 97%. Follow-up for longer than seven years was needed to identify some of the poorly-performing designs. There were differences between the stems; the Corail, used in 5456 hips, was the most frequently used stem with a survival of 97% at 15 years. Male gender was associated with an increased risk of revision of × 1.3 (95% confidence interval 1.05 to 1.52), but age and diagnosis had no influence on the results. Overall, modern uncemented femoral stems performed well. Moderate differences in survival between well-performing stems should be interpreted with caution since the differences may be caused by factors other than the stem itself


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 1 | Pages 6 - 12
1 Jan 1994
Dreinhofer K Schwarzkopf Haas N Tscherne H

From 1974 to 1989, we treated 50 patients with a simple dislocation of the hip: 38 were posterior dislocations and 12 were anterior. All dislocations primarily treated at our hospital were reduced by closed methods within three hours (mean 85 minutes (10 to 180)) and 43 were reviewed after an average follow-up of 8 years (2 to 17). It is widely held that isolated hip dislocation reduced within six hours gives an excellent outcome, but we found a significant number of complications. There were radiological signs of partial avascular necrosis in two, mild osteoarthritis in seven, and moderate degeneration in two. Heterotopic ossification was seen in four patients, but 29 of 33 MRI examinations were normal. Objective evaluation according to the Thompson and Epstein (1951) criteria showed fair and poor results in 3 of 12 anterior dislocations, but in 16 of 30 posterior dislocations. In six of the seven patients with no other severe injury, the hip had an excellent or good result; in only three of the eight patients with severe multiple injuries was this the case. The important factors in the long-term prognosis appear to be the direction of the dislocation and the overall severity of injuries


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 2 | Pages 259 - 265
1 Mar 1990
Seitsalo S Osterman K Hyvarinen H Schlenzka D Poussa M

From 1948 to 1980, 93 children and adolescents had fusion in situ for severe spondylolisthesis with a slip of 50% or more, at a mean age of 14.8 years. Of these, 52 girls and 35 boys were reviewed after a mean follow-up of 13.8 years. The mean pre-operative slip was 76% and pain frequency correlated with the severity of the lumbosacral kyphosis but not with that of the slip. Posterior fusion was used in 54, posterolateral in 30 and anterior fusion in three patients. There were no major complications but 16 had re-operations for non-union or root symptoms. At follow-up there were three non-unions. After operation, 19 patients had 10% or more progression of the slip, but 10 showed correction by more than 10% as a result of remodelling. The lumbosacral kyphosis had increased by more than 10 degrees in 45%. Postoperative progression of the slip and of lumbosacral kyphosis was significantly more if the posterior element had been removed. At follow-up 77 patients were subjectively improved, four were unchanged, and one was worse. These results did not correlate with either the degree of the slip, or the angle of lumbosacral kyphosis. Fusion in situ is safe and gives good long-term clinical results. Secondary changes are associated with increased lumbosacral kyphosis, so reduction of this should be considered in severe cases


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 4 | Pages 603 - 606
1 Jul 1991
Hooning van Duyvenbode J Keijser L Hauet E Obermann W Rozing P

We report the long-term results of the Matti-Russe operation for pseudarthrosis of the scaphoid in 100 cases, reported previously by Mulder in 1968. Clinical results for 77 patients and radiographic data for 74 were reviewed at 22 to 34.8 years after surgery. In general, there was satisfactory relief of pain and stiffness but some patients had limitation of motion and reduced grip-strength, with usually slight osteoarthritic changes. There was poor correlation between subjective, objective, and radiographic results but 88% of the patients were satisfied with their results


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 2 | Pages 210 - 216
1 Feb 2011
Young A Walch G Boileau P Favard L Gohlke F Loew M Molé D

We report the long-term clinical and radiological outcomes of the Aequalis total shoulder replacement with a cemented all-polyethylene flat-back keeled glenoid component implanted for primary osteoarthritis between 1991 and 2003 in nine European centres. A total of 226 shoulders in 210 patients were retrospectively reviewed at a mean of 122.7 months (61 to 219) or at revision. Clinical outcome was assessed using the Constant score, patient satisfaction score and range of movement. Kaplan-Meier survivorship analysis was performed with glenoid revision for loosening and radiological glenoid loosening (. sd. ) as endpoints. The Constant score was found to improve from a mean of 26.8 (. sd. 10.3) pre-operatively to 57.6 (. sd. 20.0) post-operatively (p < 0.001). Active forward flexion improved from a mean of 85.3° (. sd. 27.4) pre-operatively to 125° (. sd. 37.3) postoperatively (p < 0.001). External rotation improved from a mean of 7° (. sd. 6.5) pre-operatively to 30.3° (. sd. 21.8°) post-operatively (p < 0.001). Survivorship with revision of the glenoid component as the endpoint was 99.1% at five years, 94.5% at ten years and 79.4% at 15 years. Survivorship with radiological loosening as the endpoint was 99.1% at five years, 80.3% at ten years and 33.6% at 15 years. Younger patient age and the curettage technique for glenoid preparation correlated with loosening. The rate of glenoid revision and radiological loosening increased with duration of follow-up, but not until a follow-up of five years. Therefore, we recommend that future studies reporting radiological outcomes of new glenoid designs should report follow-up of at least five to ten years


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 7 | Pages 937 - 940
1 Jul 2012
Manopoulos P Havet E Pearce O Lardanchet JF Mertl P

This was a retrospective analysis of the medium- to long-term results of 46 TC3 Sigma revision total knee replacements using long uncemented stems in press-fit mode. Clinical and radiological analysis took place pre-operatively, at two years post-operatively, and at a mean follow-up of 8.5 years (4 to 12). The mean pre-operative International Knee Society (IKS) clinical score was 42 points (0 to 74), improving to 83.7 (52 to 100) by the final follow-up. The mean IKS score for function improved from 34.3 points (0 to 80) to 64.2 (15 to 100) at the final follow-up. At the final follow-up 30 knees (65.2%) had an excellent result, seven (15.2%) a good result, one (2.2%) a medium and eight (17.4%) a poor result. There were two failures, one with anteroposterior instability and one with aseptic loosening. The TC3 revision knee system, when used with press-fit for long intramedullary stems and cemented femoral and tibial components, in both septic and aseptic revisions, results in a satisfactory clinical and radiological outcome, and has a good medium- to long-term survival rate