Advertisement for orthosearch.org.uk
Results 141 - 160 of 166
Results per page:
The Bone & Joint Journal
Vol. 98-B, Issue 11 | Pages 1436 - 1440
1 Nov 2016
Abdel MP Roth PV Harmsen WS Berry DJ

Aims

The purpose of this study was to determine the lifetime risk of revision surgery for patients undergoing Charnley cemented total hip arthroplasty (THA), with 40-year follow up, using death as a competing risk.

Materials and Methods

We retrospectively reviewed 2000 cemented Charnley THAs, with 51 living hips available at 40 years.


The Bone & Joint Journal
Vol. 98-B, Issue 8 | Pages 1112 - 1118
1 Aug 2016
Pedersen AB Christiansen CF Gammelager H Kahlert J Sørensen HT

Aims

We examined risk of developing acute renal failure and the associated mortality among patients aged > 65 years undergoing surgery for a fracture of the hip.

Patients and Methods

We used medical databases to identify patients who underwent surgical treatment for a fracture of the hip in Northern Denmark between 2005 and 2011. Acute renal failure was classified as stage 1, 2 and 3 according to the Kidney Disease Improving Global Outcome criteria. We computed the risk of developing acute renal failure within five days after surgery with death as a competing risk, and the short-term (six to 30 days post-operatively) and long-term mortality (31 days to 365 days post-operatively). We calculated adjusted hazard ratios (HRs) for death with 95% confidence intervals (CIs).


The Bone & Joint Journal
Vol. 98-B, Issue 4 | Pages 468 - 474
1 Apr 2016
Abdel MP Houdek MT Watts CD Lewallen DG Berry DJ

Aims

The goals of this study were to define the risk factors, characteristics, and chronology of fractures in 5417 revision total hip arthroplasties (THAs).

Patients and Methods

From our hospital’s prospectively collected database we identified all patients who had undergone a revision THA between 1969 and 2011 which involved the femoral stem. The patients’ medical records and radiographs were examined and the relevant data extracted. Post-operative periprosthetic fractures were classified using the Vancouver system. A total of 5417 revision THAs were identified.


Bone & Joint 360
Vol. 4, Issue 5 | Pages 15 - 16
1 Oct 2015

The October 2015 Foot & Ankle Roundup360 looks at: TightRope in Weber C fractures; A second look at the TightRope; Incisional VAC comes of age?; Platelet-derived growth factor and ankle fusions; Achilles tendon rehab in the longer term following surgery; Telemedicine for diabetic foot ulcer


The Bone & Joint Journal
Vol. 96-B, Issue 4 | Pages 548 - 554
1 Apr 2014
Sun H Luo CF Zhong B Shi HP Zhang CQ Zeng BF

Our aim was to compare polylevolactic acid screws with titanium screws when used for fixation of the distal tibiofibular syndesmosis at mid-term follow-up. A total of 168 patients, with a mean age of 38.5 years (18 to 72) who were randomly allocated to receive either polylevolactic acid (n = 86) or metallic (n = 82) screws were included. The Baird scoring system was used to assess the overall satisfaction and functional recovery post-operatively. The demographic details and characteristics of the injury were similar in the two groups. The mean follow-up was 55.8 months (48 to 66). The Baird scores were similar in the two groups at the final follow-up. Patients in the polylevolactic acid group had a greater mean dorsiflexion (p = 0.011) and plantar-flexion of the injured ankles (p < 0.001). In the same group, 18 patients had a mild and eight patients had a moderate foreign body reaction. In the metallic groups eight had mild and none had a moderate foreign body reaction (p <  0.001). In total, three patients in the polylevolactic acid group and none in the metallic group had heterotopic ossification (p = 0.246).

We conclude that both screws provide adequate fixation and functional recovery, but polylevolactic acid screws are associated with a higher incidence of foreign body reactions.

Cite this article: Bone Joint J 2014;96-B:548–54.


Bone & Joint 360
Vol. 4, Issue 4 | Pages 16 - 18
1 Aug 2015

The August 2015 Knee Roundup360 looks at: Two days as good as three in TKA; Bilateral TKA: minimising the risks; Tranexamic acid in knee arthroplasty: everyone should be using it, but how?; Initial follow-up for knee arthroplasty?; Navigation finds its niche?; Another take on navigation?; Multimodal care for early knee osteoarthritis; ACL graft fixation methods under the spotlight


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 2 | Pages 164 - 171
1 Feb 2011
Langton DJ Joyce TJ Jameson SS Lord J Van Orsouw M Holland JP Nargol AVF De Smet KA

We sought to establish the incidence of joint failure secondary to adverse reaction to metal debris (ARMD) following metal-on-metal hip resurfacing in a large, three surgeon, multicentre study involving 4226 hips with a follow-up of 10 to 142 months. Three implants were studied: the Articular Surface Replacement; the Birmingham Hip Resurfacing; and the Conserve Plus. Retrieved implants underwent analysis using a co-ordinate measuring machine to determine volumetric wear. There were 58 failures associated with ARMD. The median chromium and cobalt concentrations in the failed group were significantly higher than in the control group (p < 0.001). Survival analysis showed a failure rate in the patients with Articular Surface Replacement of 9.8% at five years, compared with < 1% at five years for the Conserve Plus and 1.5% at ten years for the Birmingham Hip Resurfacing. Two ARMD patients had relatively low wear of the retrieved components. Increased wear from the metal-on-metal bearing surface was associated with an increased rate of failure secondary to ARMD. However, the extent of tissue destruction at revision surgery did not appear to be dose-related to the volumetric wear.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 6 | Pages 856 - 861
1 Jun 2010
Emms NW Stockley I Hamer AJ Wilkinson JM

Between 1988 and 1998 we implanted 318 total hip replacements (THRs) in 287 patients using the Plasmacup (B. Braun Ltd, Sheffield, United Kingdom) and a conventional metal-on-polyethylene articulation. The main indications for THR were primary or secondary osteoarthritis.

At follow-up after a mean 11.6 years (7.6 to 18.4) 17 patients had died and 20 could not be traced leaving a final series of 280 THRs in 250 patients. There were 62 revisions (22.1%) in 59 patients. A total of 43 acetabular shells (15.4%) had been revised and 13 (4.6%) had undergone exchange of the liner. The most frequent indications for revision were osteolysis and aseptic loosening, followed by polyethylene wear. The mean Kaplan-Meier survival of the Plasmacup was 91% at ten years and 58% at 14 years. Osteolysis was found around 36 (17.1%) of the 211 surviving shells. The median annual rate of linear wear in the surviving shells was 0.12 mm/year and 0.25 mm/year in those which had been revised (p < 0.001). Polyethylene wear was a strong independent risk factor for osteolysis and aseptic loosening. The percentage of patients with osteolysis increased proportionately with each quintile of wear-rate.

There is a high late rate of failure of the Plasmacup. Patients with the combination of this prosthesis and bearing should be closely monitored after ten years.


Bone & Joint 360
Vol. 3, Issue 1 | Pages 14 - 17
1 Feb 2014

The February 2014 Hip & Pelvis Roundup360 looks at: length of stay; cementless metaphyseal fixation; mortality trends in over 400,000 total hip replacements; antibiotics in hip fracture surgery; blood supply to the femoral head after dislocation; resurfacing and THR in metal-on-metal replacement; diabetes and hip replacement; bone remodelling over two decades following hip replacement; and whether bisphosphonates affect acetabular fixation.


Bone & Joint 360
Vol. 2, Issue 6 | Pages 22 - 24
1 Dec 2013

The December 2013 Shoulder & Elbow Roundup360 looks at: Platelet-rich plasma; Arthroscopic treatment of sternoclavicular joint osteoarthritis; Synchronous arthrolysis and cuff repair; Arthroscopic arthrolysis; Regional blockade in the beach chair; Recurrent instability; Avoiding iatrogenic nerve injury in elbow arthroscopy; and Complex reconstruction of total elbow revisions


The Bone & Joint Journal
Vol. 96-B, Issue 1 | Pages 88 - 93
1 Jan 2014
Venkatesan M Northover JR Wild JB Johnson N Lee K Uzoigwe CE Braybrooke JR

Fractures of the odontoid peg are common spinal injuries in the elderly. This study compares the survivorship of a cohort of elderly patients with an isolated fracture of the odontoid peg versus that of patients who have sustained a fracture of the hip or wrist. A six-year retrospective analysis was performed on all patients aged > 65 years who were admitted to our spinal unit with an isolated fracture of the odontoid peg. A Kaplan–Meier table was used to analyse survivorship from the date of fracture, which was compared with the survivorship of similar age-matched cohorts of 702 consecutive patients with a fracture of the hip and 221 consecutive patients with a fracture of the wrist.

A total of 32 patients with an isolated odontoid fracture were identified. The rate of mortality was 37.5% (n = 12) at one year. The period of greatest mortality was within the first 12 weeks. Time made a lesser contribution from then to one year, and there was no impact of time on the rate of mortality thereafter. The rate of mortality at one year was 41.2% for male patients (7 of 17) compared with 33.3% for females (5 of 15).

The rate of mortality at one year was 32% (225 of 702) for patients with a fracture of the hip and 4% (9 of 221) for those with a fracture of the wrist. There was no statistically significant difference in the rate of mortality following a hip fracture and an odontoid peg fracture (p = 0.95). However, the survivorship of the wrist fracture group was much better than that of the odontoid peg fracture group (p < 0.001). Thus, a fracture of the odontoid peg in the elderly is not a benign injury and is associated with a high rate of mortality, especially in the first three months after the injury.

Cite this article: Bone Joint J 2014;96-B:88–93.


Bone & Joint 360
Vol. 2, Issue 3 | Pages 33 - 35
1 Jun 2013

The June 2013 Oncology Roundup360 looks at: whether allograft composite is superior to megaprosthesis in massive reconstruction; pain from glomus tumours; thromboembolism and orthopaedic malignancy; bone marrow aspirate and cavity lesions; metastasectomy in osteosarcoma; spinal giant cell tumour; post-atomic strike sarcoma; and superficial sarcomas and post-operative infection rates.


Bone & Joint 360
Vol. 2, Issue 3 | Pages 23 - 25
1 Jun 2013

The June 2013 Foot & Ankle Roundup360 looks at: soft-tissue pain following arthroplasty; pigmented villonodular synovitis of the foot and ankle; ankles, allograft and arthritis; open calcaneal fracture; osteochondral lesions in the longer term; severe infections in diabetic feet; absorbable first ray fixation; and showering after foot surgery.


Bone & Joint 360
Vol. 2, Issue 1 | Pages 35 - 37
1 Feb 2013

The February 2013 Children’s orthopaedics Roundup360 looks at: ABC treated with suction and curettage; peri-acetabular osteotomy; cast index; Perthes’ disease associated with accidental injury; brachial plexus birth palsy; MRI assessment of DDH; total meniscectomy; and paediatric septic arthritis.


Bone & Joint 360
Vol. 2, Issue 2 | Pages 12 - 15
1 Apr 2013

The April 2013 Knee Roundup360 looks at: graft tension and outcome; chondrocytes at the midterm; pre-operative deformity and failure; the designer effect; whether chondroitin sulphate really does work; whether ACL reconstruction is really required; analgesia after TKR; and degenerative meniscus.


The Bone & Joint Journal
Vol. 95-B, Issue 3 | Pages 411 - 418
1 Mar 2013
Nakamura T Grimer RJ Gaston CL Watanuki M Sudo A Jeys L

The aim of this study was to determine whether the level of circulating C-reactive protein (CRP) before treatment predicted overall disease-specific survival and local tumour control in patients with a sarcoma of bone.

We retrospectively reviewed 318 patients who presented with a primary sarcoma of bone between 2003 and 2010. Those who presented with metastases and/or local recurrence were excluded.

Elevated CRP levels were seen in 84 patients before treatment; these patients had a poorer disease-specific survival (57% at five years) than patients with a normal CRP (79% at five years) (p < 0.0001). They were also less likely to be free of recurrence (71% at five years) than patients with a normal CRP (79% at five years) (p = 0.04). Multivariate analysis showed the pre-operative CRP level to be an independent predictor of survival and local control. Patients with a Ewing’s sarcoma or chondrosarcoma who had an elevated CRP before their treatment started had a significantly poorer disease-specific survival than patients with a normal CRP (p = 0.02 and p < 0.0001, respectively). Patients with a conventional osteosarcoma and a raised CRP were at an increased risk of poorer local control.

We recommend that CRP levels are measured routinely in patients with a suspected sarcoma of bone as a further prognostic indicator of survival.

Cite this article: Bone Joint J 2013;95-B:411–18.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 12 | Pages 1567 - 1573
1 Dec 2006
Kovac S Trebse R Milosev I Pavlovcic V Pisot V

We present a retrospective series of 170 cemented titanium straight-stem femoral components combined with two types of femoral head: cobalt-chromium (CoCr) alloy (114 heads) and alumina ceramic (50 heads). Of the study group, 55 patients (55 stems) had died and six (six stems) were lost to follow-up. At a mean of 13.1 years (3 to 15.3) 26 stems had been revised for aseptic loosening. The mean follow-up time for stable stems was 15.1 years (12.1 to 16.6).

Survival of the stem at 15 years was 75.4% (95% confidence interval (CI) 67.3 to 83.5) with aseptic failure (including radiological failure) as the end-point, irrespective of the nature of the head and the quality of the cement mantle. Survival of the stem at 15 years was 79.1% (95% CI 69.8 to 88.4) and 67.1% (95% CI 51.3 to 82.9) with the CoCr alloy and ceramic heads, respectively. The quality of the cement mantle was graded as a function of stem coverage: stems with complete tip coverage (type 1) had an 84.9% (95% CI 77.6 to 92.2) survival at 15 years, compared with those with a poor tip coverage (type 2) which had a survival of only 22.4% (95% CI 2.4 to 42.4). The poor quality of the cement mantle and the implantation of an alumina head substantially lowered the survival of the stem.

In our opinion, further use of the cemented titanium alloy straight-stem femoral components used in our series is undesirable.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 2 | Pages 200 - 204
1 Feb 2012
Clement ND Jenkins PJ Brenkel IJ Walmsley P

We report the general mortality rate after total knee replacement and identify independent predictors of survival. We studied 2428 patients: there were 1127 men (46%) and 1301 (54%) women with a mean age of 69.3 years (28 to 94). Patients were allocated a predicted life expectancy based on their age and gender.

There were 223 deaths during the study period. This represented an overall survivorship of 99% (95% confidence interval (CI) 98 to 99) at one year, 90% (95% CI 89 to 92) at five years, and 84% (95% CI 82 to 86) at ten years. There was no difference in survival by gender. A greater mortality rate was associated with increasing age (p < 0.001), American Society of Anesthesiologists (ASA) grade (p < 0.001), smoking (p < 0.001), body mass index (BMI) <  20 kg/m2 (p < 0.001) and rheumatoid arthritis (p < 0.001). Multivariate modelling confirmed the independent effect of age, ASA grade, BMI, and rheumatoid disease on mortality. Based on the predicted average mortality, 114 patients were predicted to have died, whereas 217 actually died. This resulted in an overall excess standardised mortality ratio of 1.90. Patient mortality after TKR is predicted by their demographics: these could be used to assign an individual mortality risk after surgery.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 4 | Pages 471 - 476
1 Apr 2012
Holland JP Langton DJ Hashmi M

We present the clinical results and survivorship of consecutive 100 Birmingham Hip Resurfacings in 90 patients at a minimum follow-up of ten years. All procedures were carried out by an independent surgeon who commenced a prospective study in 1998. Patients were assessed clinically using the Western Ontario and McMaster Universities osteoarthritis index, Short-Form 36, Harris hip score and University of California, Los Angeles activity score. Radiological analysis was performed by an independent observer and blood metal ion levels concentrations were measured at ten years post-operatively in 62 patients. The median acetabular component inclination was 46.2° (34° to 59°) and anteversion 11.0° (0° to 30°). The median chromium concentration in the unilateral group was 1.74 (0.41 to 15.23) and for the bilateral group was 2.98 (1.57 to 18.01). The equivalent values for cobalt were 1.67 (0.54 to 20.4) and 1.88 (1.38 to 19.32).

In total there were eight failures giving an overall survival at ten years of 92% (95% confidence interval (CI) 86.7 to 97.3). BHR in male patients had an improved survivorship of 94.6% (95% CI 89.4 to 100) compared with females at 84.6% (95% CI 70.7 to 98.5), but this did not reach statistical significance (p = 0.119). Four of the nine BHRs with a bearing diameter of 42 mm failed.

The overall results were consistent with data produced from other centres in that the clinical outcome of large male patients was extremely encouraging, whereas the survival of the smaller joints was less satisfactory.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 5 | Pages 658 - 664
1 May 2011
Karantana A Boulton C Bouliotis G Shu KSS Scammell BE Moran CG

We examined prospectively collected data from 6782 consecutive hip fractures and identified 327 fractures in 315 women aged ≤65 years. We report on their demographic characteristics, treatment and outcome and compare them with a cohort of 4810 hip fractures in 4542 women aged > 65 years.

The first significant increase in age-related incidence of hip fracture was at 45, rather than 50, which is when screening by the osteoporosis service starts in most health areas. Hip fractures in younger women are sustained by a population at risk as a result of underlying disease. Mortality of younger women with hip fracture was 46 times the background mortality of the female population. Smoking had a strong influence on the relative risk of ‘early’ (≤ 65 years of age) fracture.

Lag screw fixation was the most common method of operative treatment. General complication rates were low, as were re-operation rates for cemented prostheses. Kaplan-Meier implant survivorship of displaced intracapsular fractures treated by reduction and lag screw fixation was 71% (95% confidence interval 56 to 81) at five years. The best form of treatment remains controversial.