Advertisement for orthosearch.org.uk
Results 1561 - 1580 of 2174
Results per page:
Bone & Joint 360
Vol. 2, Issue 6 | Pages 28 - 31
1 Dec 2013

The December 2013 Oncology Roundup360 looks at: Peri-articular resection fraught with complications; Navigated margins; Skeletal tumours and thromboembolism; Conditional survival in Ewing’s sarcoma; Reverse shoulders and tumour; For how long should we follow up sarcoma patients?; and already metastasised?


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 57 - 62
1 Nov 2013
Stulberg SD Patel RM

Conventional uncemented femoral implants provide dependable long-term fixation in patients with a wide range of functional requirements. Yet challenges associated with proximal–distal femoral dimensional mismatch, preservation of bone stock, and minimally invasive approaches have led to exploration into alternative implant designs. Short stem designs focusing on a stable metaphyseal fit have emerged to address these issues in total hip replacement (THR). Uncemented metaphyseal-engaging short stem implants are stable and are associated with proximal bone remodeling closer to the metaphysis when compared with conventional stems and they also have comparable clinical performances. Short stem metaphyseal-engaging implants can meet the goals of a successful THR, including tolerating a high level of patient function, as well as durable fixation.

Cite this article: Bone Joint J 2013;95-B, Supple A:57–62.


The Bone & Joint Journal
Vol. 95-B, Issue 10 | Pages 1406 - 1409
1 Oct 2013
Wähnert D Lange JH Schulze M Gehweiler D Kösters C Raschke MJ

The augmentation of fixation with bone cement is increasingly being used in the treatment of severe osteoporotic fractures. We investigated the influence of bone quality on the mechanics of augmentation of plate fixation in a distal femoral fracture model (AO 33 A3 type). Eight osteoporotic and eight non-osteoporotic femoral models were randomly assigned to either an augmented or a non-augmented group. Fixation was performed using a locking compression plate. In the augmented group additionally 1 ml of bone cement was injected into the screw hole before insertion of the screw. Biomechanical testing was performed in axial sinusoidal loading. Augmentation significantly reduced the cut-out distance in the osteoporotic models by about 67% (non-augmented mean 0.30 mm (sd 0.08) vs augmented 0.13 mm (sd 0.06); p = 0.017). There was no statistical reduction in this distance following augmentation in the non-osteoporotic models (non-augmented mean 0.15 mm (sd 0.02) vs augmented 0.15 mm (sd 0.07); p = 0.915). In the osteoporotic models, augmentation significantly increased stability (p = 0.017).

Cite this article: Bone Joint J 2013;95-B:1406–9.


The Bone & Joint Journal
Vol. 96-B, Issue 1 | Pages 36 - 42
1 Jan 2014
Liebs T Nasser L Herzberg W Rüther W Hassenpflug J

Several factors have been implicated in unsatisfactory results after total hip replacement (THR). We examined whether femoral offset, as measured on digitised post-operative radiographs, was associated with pain after THR. The routine post-operative radiographs of 362 patients (230 women and 132 men, mean age 70.0 years (35.2 to 90.5)) who received primary unilateral THRs of varying designs were measured after calibration. The femoral offset was calculated using the known dimensions of the implants to control for femoral rotation. Femoral offset was categorised into three groups: normal offset (within 5 mm of the height-adjusted femoral offset), low offset and high offset. We determined the associations to the absolute final score and the improvement in the mean Western Ontario and McMaster Universities osteoarthritis index (WOMAC) pain subscale scores at three, six, 12 and 24 months, adjusting for confounding variables.

The amount of femoral offset was associated with the mean WOMAC pain subscale score at all points of follow-up, with the low-offset group reporting less WOMAC pain than the normal or high-offset groups (six months: 7.01 (sd 11.69) vs 12.26 (sd 15.10) vs 13.10 (sd 16.20), p = 0.006; 12 months: 6.55 (sd 11.09) vs 9.73 (sd 13.76) vs 13.46 (sd 18.39), p = 0.010; 24 months: 5.84 (sd 10.23) vs 9.60 (sd 14.43) vs 13.12 (sd 17.43), p = 0.004). When adjusting for confounding variables, including age and gender, the greatest improvement was seen in the low-offset group, with the normal-offset group demonstrating more improvement than the high-offset group.

Cite this article: Bone Joint J 2014;96-B:36–42.


The Bone & Joint Journal
Vol. 95-B, Issue 11 | Pages 1458 - 1463
1 Nov 2013
Won S Lee Y Ha Y Suh Y Koo K

Pre-operative planning for total hip replacement (THR) is challenging in hips with severe acetabular deformities, including those with a hypoplastic acetabulum or severe defects and in the presence of arthrodesis or ankylosis. We evaluated whether a Rapid Prototype (RP) model, which is a life-sized reproduction based on three-dimensional CT scans, can determine the feasibility of THR and provide information about the size and position of the acetabular component in severe acetabular deformities. THR was planned using an RP model in 21 complex hips in five men (five hips) and 16 women (16 hips) with a mean age of 47.7 years (24 to 70) at operation. An acetabular component was implanted successfully and THR completed in all hips. The acetabular component used was within 2 mm of the predicted size in 17 hips (80.9%). All of the acetabular components and femoral stems had radiological evidence of bone ingrowth and stability at the final follow-up, without any detectable wear or peri-prosthetic osteolysis. The RP model allowed a simulated procedure pre-operatively and was helpful in determining the feasibility of THR pre-operatively, and to decide on implant type, size and position in complex THRs.

Cite this article: Bone Joint J 2013;95-B:1458–63.


Bone & Joint Research
Vol. 2, Issue 11 | Pages 233 - 237
1 Nov 2013
Russell DF Deakin AH Fogg QA Picard F

Objectives

We performed in vitro validation of a non-invasive skin-mounted system that could allow quantification of anteroposterior (AP) laxity in the outpatient setting.

Methods

A total of 12 cadaveric lower limbs were tested with a commercial image-free navigation system using trackers secured by bone screws. We then tested a non-invasive fabric-strap system. The lower limb was secured at 10° intervals from 0° to 60° of knee flexion and 100 N of force was applied perpendicular to the tibia. Acceptable coefficient of repeatability (CR) and limits of agreement (LOA) of 3 mm were set based on diagnostic criteria for anterior cruciate ligament (ACL) insufficiency.


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 11 - 16
1 Nov 2013
Sierra RJ Mabry TM Sems SA Berry DJ

Total hip replacement (THR) after acetabular fracture presents unique challenges to the orthopaedic surgeon. The majority of patients can be treated with a standard THR, resulting in a very reasonable outcome. Technical challenges however include infection, residual pelvic deformity, acetabular bone loss with ununited fractures, osteonecrosis of bone fragments, retained metalwork, heterotopic ossification, dealing with the sciatic nerve, and the difficulties of obtaining long-term acetabular component fixation. Indications for an acute THR include young patients with both femoral head and acetabular involvement with severe comminution that cannot be reconstructed, and the elderly, with severe bony comminution. The outcomes of THR for established post-traumatic arthritis include excellent pain relief and functional improvements. The use of modern implants and alternative bearing surfaces should improve outcomes further.

Cite this article: Bone Joint J 2013;95-B, Supple A:11–16.


The Bone & Joint Journal
Vol. 95-B, Issue 11 | Pages 1453 - 1457
1 Nov 2013
Zlotorowicz M Czubak J Caban A Kozinski P Boguslawska-Walecka R

The femoral head receives blood supply mainly from the deep branch of the medial femoral circumflex artery (MFCA). In previous studies we have performed anatomical dissections of 16 specimens and subsequently visualised the arteries supplying the femoral head in 55 healthy individuals. In this further radiological study we compared the arterial supply of the femoral head in 35 patients (34 men and one woman, mean age 37.1 years (16 to 64)) with a fracture/dislocation of the hip with a historical control group of 55 hips. Using CT angiography, we identified the three main arteries supplying the femoral head: the deep branch and the postero-inferior nutrient artery both arising from the MFCA, and the piriformis branch of the inferior gluteal artery. It was possible to visualise changes in blood flow after fracture/dislocation.

Our results suggest that blood flow is present after reduction of the dislocated hip. The deep branch of the MFCA was patent and contrast-enhanced in 32 patients, and the diameter of this branch was significantly larger in the fracture/dislocation group than in the control group (p = 0.022). In a subgroup of ten patients with avascular necrosis (AVN) of the femoral head, we found a contrast-enhanced deep branch of the MFCA in eight hips. Two patients with no blood flow in any of the three main arteries supplying the femoral head developed AVN.

Cite this article: Bone Joint J 2013;95-B:1453–7.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 3 | Pages 365 - 372
1 Mar 2012
Cheng B Li FT Lin L

Diastematomyelia is a rare congenital abnormality of the spinal cord. This paper summarises more than 30 years’ experience of treating this condition. Data were collected retrospectively on 138 patients with diastematomyelia (34 males, 104 females) who were treated at our hospital from May 1978 to April 2010. A total of 106 patients had double dural tubes (type 1 diastematomyelia), and 32 patients had single dural tubes (type 2 diastematomyelia). Radiographs, CT myelography, and MRI showed characteristic kyphoscoliosis, widening of the interpedicle distance, and bony, cartilaginous, and fibrous septum. The incidences of symptoms including characteristic changes of the dorsal skin, neurological disorders, and congenital spinal or foot deformity were significantly higher in type 1 than in type 2. Surgery is more effective for patients with type 1 diastematomyelia; patients without surgery showed no improvement.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 9 | Pages 1278 - 1281
1 Sep 2010
Badhe S Lynch J Thorpe SKS Bainbridge LC

Linburg-Comstock syndrome is characterised by an anomalous tendon slip from the flexor pollicis longus to the flexor digitorum profundus, usually of the index finger. An incidence as high as 60% to 70% has been reported. Post-traumatic inflammation of inter-tendinous connections between the flexor pollicis longus and flexor digitorum profundus, usually of the index finger, may cause unexplained chronic pain in the distal forearm. A total of 11 patients (eight females, three males), mean age 29.1 years (14 to 47) with a clinical diagnosis of Linburg-Comstock syndrome underwent surgical release of the inter-tendinous connection. The mean follow-up was for 27 months (2 to 48).

Ten patients reported excellent relief of pain in the forearm, with independent flexion of flexor pollicis longus and flexor digitorum profundus to the index finger. Surgical release was an effective treatment for the Linburg-Comstock syndrome in this series.


The Bone & Joint Journal
Vol. 95-B, Issue 10 | Pages 1388 - 1391
1 Oct 2013
Fushimi K Miyamoto K Hioki A Hosoe H Takeuchi A Shimizu K

There have been a few reports of patients with a combination of lumbar and thoracic spinal stenosis. We describe six patients who suffered unexpected acute neurological deterioration at a mean of 7.8 days (6 to 10) after lumbar decompressive surgery. Five had progressive weakness and one had recurrent pain in the lower limbs. There was incomplete recovery following subsequent thoracic decompressive surgery.

The neurological presentation can be confusing. Patients with compressive myelopathy due to lower thoracic lesions, especially epiconus lesions (T10 to T12/L1 disc level), present with similar symptoms to those with lumbar radiculopathy or cauda equina lesions. Despite the rarity of this condition we advise that patients who undergo lumbar decompressive surgery for stenosis should have sagittal whole spine MRI studies pre-operatively to exclude proximal neurological compression.

Cite this article: Bone Joint J 2013;95-B:1388–91.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 11 | Pages 1571 - 1574
1 Nov 2011
Dokai T Nagashima H Nanjo Y Tanida A Teshima R

We present the case of a 15-year-old boy with symptoms due to Klippel–Feil syndrome. Radiographs and CT scans demonstrated basilar impression, occipitalisation of C1 and fusion of C2/C3. MRI showed ventral compression of the medullocervical junction. Skull traction was undertaken pre-operatively to determine whether the basilar impression could be safely reduced. During traction, the C3/C4 junction migrated 12 mm caudally and spasticity resolved. Peri-operative skull-femoral traction enabled posterior occipitocervical fixation without decompression. Following surgery, cervical alignment was restored and spasticity remained absent. One year after surgery he was not limited in his activities. The surgical strategy for patients with basilar impression and congenital anomalies remains controversial. The anterior approach with decompression is often recommended for patients with ventral compression of the medullocervical region, but such procedures are technically demanding and carry a significant risk of complications. Our surgical strategy was an alternative solution. Prior to a posterior cervical fixation, without decompression, skull traction was used to confirm that the deformity was reducible and effective in resolving associated myelopathy.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 8 | Pages 1111 - 1117
1 Aug 2011
Sewell MD Hanna SA McGrath A Aston WJS Blunn GW Pollock RC Skinner JA Cannon SR Briggs TWR

The best method of reconstruction after resection of malignant tumours of the tibial diaphysis is unknown. In the absence of any long-term studies analysing the results of intercalary endoprosthetic replacement, we present a retrospective review of 18 patients who underwent limb salvage using a tibial diaphyseal endoprosthetic replacement following excision of a malignant bone tumour. There were ten men and eight women with a mean age of 42.5 years (16 to 76). Mean follow-up was 58.5 months (20 to 141) for all patients and 69.3 months (20 to 141) for the 12 patients still alive. Cumulative patient survival was 59% (95% confidence interval (CI) 32 to 84) at five years. Implant survival was 63% (95% CI 35 to 90) at ten years. Four patients required revision to a proximal tibial replacement at a mean follow-up of 29 months (10 to 54). Complications included metastases in five patients, aseptic loosening in four, peri-prosthetic fracture in two, infection in one and local recurrence in one. The mean Musculoskeletal Tumor Society score and the mean Toronto Extremity Salvage Score were 23 (17 to 28) and 74% (53 to 91), respectively.

Although rates of complication and revision were high, custom-made tibial diaphyseal replacement following resection of malignant bone tumours enables early return to function and provides an attractive alternative to other surgical options, without apparent compromise of patient survival.


Bone & Joint Research
Vol. 3, Issue 2 | Pages 20 - 31
1 Feb 2014
Kiapour AM Murray MM

Injury to the anterior cruciate ligament (ACL) is one of the most devastating and frequent injuries of the knee. Surgical reconstruction is the current standard of care for treatment of ACL injuries in active patients. The widespread adoption of ACL reconstruction over primary repair was based on early perception of the limited healing capacity of the ACL. Although the majority of ACL reconstruction surgeries successfully restore gross joint stability, post-traumatic osteoarthritis is commonplace following these injuries, even with ACL reconstruction. The development of new techniques to limit the long-term clinical sequelae associated with ACL reconstruction has been the main focus of research over the past decades. The improved knowledge of healing, along with recent advances in tissue engineering and regenerative medicine, has resulted in the discovery of novel biologically augmented ACL-repair techniques that have satisfactory outcomes in preclinical studies. This instructional review provides a summary of the latest advances made in ACL repair.

Cite this article: Bone Joint Res 2014;3:20–31.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 8 | Pages 1152 - 1159
1 Aug 2010
Hayek S Gershon A Wientroub S Yizhar Z

Our aim was to evaluate the effect of adding inhibitory casting to the treatment of young children with cerebral palsy who received injections of botulinum neurotoxin A (BoNT-A) to gastrocnemius for equinus gait. Of the 20 patients in the series, 11 in group A had inhibitory casts applied on the day of the first set of BoNT-A injections and nine in group B did not have casting. Both groups received another BoNT-A injection four months later. The patients were followed for eight months and examined at five intervals.

Both groups showed significant improvement in gait parameters and function (p < 0.0001) and selective motor control (p = 0.041, − 0.036) throughout the study. Group A had significantly better passive dorsiflexion of the ankle (p = 0.029), observational gait score (p = 0.006) and selective motor control (p = 0.036). We conclude that the addition of inhibitory casting enhances and prolongs the results of treatment and mainly influences the passive range of movement, while BoNT-A mostly influences the dynamic motion. The second injection further improved the results of most parameters. The gross motor function measure, the selective motor control test and the modified Tardieu scale correlated well with the results of treatment.

We recommend the use of inhibitory casting whenever augmentation of the effect of treatment with BoNT-A is needed.


Bone & Joint 360
Vol. 1, Issue 4 | Pages 31 - 33
1 Aug 2012

The August 2012 Research Roundup360 looks at: PRP and chondrogenic differentiation; basic fibroblast growth factor; whether glucosamine works; randomised trials; ossification of the ligamentum flavum; treadmill running; inhibiting BMP antagonists; and whether NSAIDs delay union after all.


The Bone & Joint Journal
Vol. 95-B, Issue 8 | Pages 1009 - 1010
1 Aug 2013
Haddad FS


The aims of this study were to assess the efficacy of a newly designed radiological technique (the radial groove view) for the detection of protrusion of screws in the groove for the extensor pollicis longus tendon (EPL) during plating of distal radial fractures. We also aimed to determine the optimum position of the forearm to obtain this view. We initially analysed the anatomy of the EPL groove by performing three-dimensional CT on 51 normal forearms. The mean horizontal angle of the groove was 17.8° (14° to 23°). We found that the ideal position of the fluoroscopic beam to obtain this view was 20° in the horizontal plane and 5° in the sagittal plane.

We then intra-operatively assessed the use of the radial groove view for detecting protrusion of screws in the EPL groove in 93 fractures that were treated by volar plating. A total of 13 protruding screws were detected. They were changed to shorter screws and these patients underwent CT scans of the wrist immediately post-operatively. There remained one screw that was protruding. These findings suggest that the use of the radial groove view intra-operatively is a good method of assessing the possible protrusion of screws into the groove of EPL when plating a fracture of the distal radius.

Cite this article: Bone Joint J 2013;95-B:1372–6.


Bone & Joint 360
Vol. 2, Issue 5 | Pages 27 - 29
1 Oct 2013

The October 2013 Shoulder & Elbow Roundup360 looks at: Deltoid impairment not necessarily a contra-indication for shoulder arthroplasty; The tricky radiograph; Not so asymptomatic cuff tears; Total shoulder arthroplasty: kinder on the glenoid; Barbotage for calcific tendonitis; What happens to the arthritic glenoid?; Two screws a screw too few?; Sloppy hinge best for elbow arthroplasty.


The Bone & Joint Journal
Vol. 95-B, Issue 11 | Pages 1527 - 1532
1 Nov 2013
Spiro AS Rupprecht M Stenger P Hoffman M Kunkel P Kolb JP Rueger JM Stuecker R

A combined anterior and posterior surgical approach is generally recommended in the treatment of severe congenital kyphosis, despite the fact that the anterior vascular supply of the spine and viscera are at risk during exposure. The aim of this study was to determine whether the surgical treatment of severe congenital thoracolumbar kyphosis through a single posterior approach is feasible, safe and effective.

We reviewed the records of ten patients with a mean age of 11.1 years (5.4 to 14.1) who underwent surgery either by pedicle subtraction osteotomy or by vertebral column resection with instrumented fusion through a single posterior approach.

The mean kyphotic deformity improved from 59.9° (45° to 110°) pre-operatively to 17.5° (3° to 40°) at a mean follow-up of 47.0 months (29 to 85). Spinal cord monitoring was used in all patients and there were no complications during surgery. These promising results indicate the possible advantages of the described technique over the established procedures. We believe that surgery should be performed in case of documented progression and before structural secondary curves develop. Our current strategy after documented progression is to recommend surgery at the age of five years and when 90% of the diameter of the spinal canal has already developed.

Cite this article: Bone Joint J 2013;95-B:1527–32.