Advertisement for orthosearch.org.uk
Results 1481 - 1500 of 2553
Results per page:
Bone & Joint Research
Vol. 4, Issue 10 | Pages 170 - 175
1 Oct 2015
Sandberg OH Aspenberg P

Objectives

Healing in cancellous metaphyseal bone might be different from midshaft fracture healing due to different access to mesenchymal stem cells, and because metaphyseal bone often heals without a cartilaginous phase. Inflammation plays an important role in the healing of a shaft fracture, but if metaphyseal injury is different, it is important to clarify if the role of inflammation is also different. The biology of fracture healing is also influenced by the degree of mechanical stability. It is unclear if inflammation interacts with stability-related factors.

Methods

We investigated the role of inflammation in three different models: a metaphyseal screw pull-out, a shaft fracture with unstable nailing (IM-nail) and a stable external fixation (ExFix) model. For each, half of the animals received dexamethasone to reduce inflammation, and half received control injections. Mechanical and morphometric evaluation was used.


The Bone & Joint Journal
Vol. 98-B, Issue 11 | Pages 1463 - 1470
1 Nov 2016
Grammatopoulos G Alvand A Martin H Whitwell D Taylor A Gibbons CLMH

Objectives

A possible solution for the management of proximal femoral bone loss is a modular femoral endoprosthesis (EPR). Although the outcome of EPRs in tumour surgery has been well described, the outcome of their use in revision hip surgery has received less attention. The aim of this study was to describe the outcome of using EPR for non-neoplastic indications.

Methods

A retrospective review of 79 patients who underwent 80 EPRs for non-neoplastic indications was performed, including the rates of complication and survival and the mean Oxford Hip Scores (OHS), at a mean of five years post-operatively. The mean age at the time of surgery was 69 years (28 to 93) and the mean number of previous operations on the hip was 2.4 (0 to 17). The most common indications for EPR implantation were periprosthetic joint infection (PJI) (n = 40), periprosthetic fracture (n = 12) and failed osteosynthesis of a proximal femoral fracture or complex trauma (n = 11).


Bone & Joint Research
Vol. 5, Issue 11 | Pages 531 - 537
1 Nov 2016
Burgo FJ Mengelle DE Ozols A Fernandez C Autorino CM

Objectives

Studies reporting specifically on squeaking in total hip arthroplasty have focused on cementless, and not on hybrid, fixation. We hypothesised that the cement mantle of the femur might have a damping effect on the sound transmitted through the metal stem. The objective of this study was to test the effect of cement on sound propagation along different stem designs and under different fixation conditions.

Methods

An in vitro model for sound detection, composed of a mechanical suspension structure and a sound-registering electronic assembly, was designed. A pulse of sound in the audible range was propagated along bare stems and stems implanted in cadaveric bone femurs with and without cement. Two stems of different alloy and geometry were compared.


The Bone & Joint Journal
Vol. 98-B, Issue 5 | Pages 579 - 584
1 May 2016
Osman K Panagiotidou AP Khan M Blunn G Haddad FS

There is increasing global awareness of adverse reactions to metal debris and elevated serum metal ion concentrations following the use of second generation metal-on-metal total hip arthroplasties. The high incidence of these complications can be largely attributed to corrosion at the head-neck interface. Severe corrosion of the taper is identified most commonly in association with larger diameter femoral heads. However, there is emerging evidence of varying levels of corrosion observed in retrieved components with smaller diameter femoral heads. This same mechanism of galvanic and mechanically-assisted crevice corrosion has been observed in metal-on-polyethylene and ceramic components, suggesting an inherent biomechanical problem with current designs of the head-neck interface.

We provide a review of the fundamental questions and answers clinicians and researchers must understand regarding corrosion of the taper, and its relevance to current orthopaedic practice.

Cite this article: Bone Joint J 2016;98-B:579–84.


The Bone & Joint Journal
Vol. 98-B, Issue 1_Supple_A | Pages 14 - 17
1 Jan 2016
Sentuerk U von Roth P Perka C

The leading indication for revision total hip arthroplasty (THA) remains aseptic loosening owing to wear. The younger, more active patients currently undergoing THA present unprecedented demands on the bearings. Ceramic-on-ceramic (CoC) bearings have consistently shown the lowest rates of wear. The recent advances, especially involving alumina/zirconia composite ceramic, have led to substantial improvements and good results in vitro.

Alumina/zirconia composite ceramics are extremely hard, scratch resistant and biocompatible. They offer a low co-efficient of friction and superior lubrication and lower rates of wear compared with other bearings. The major disadvantage is the risk of fracture of the ceramic. The new composite ceramic has reduced the risk of fracture of the femoral head to 0.002%. The risk of fracture of the liner is slightly higher (0.02%).

Assuming that the components are introduced without impingement, CoC bearings have major advantages over other bearings. Owing to the superior hardness, they produce less third body wear and are less vulnerable to intra-operative damage.

The improved tribology means that CoC bearings are an excellent choice for young, active patients requiring THA.

Cite this article: Bone Joint J 2016;98-B(1 Suppl A):14–17.


The Bone & Joint Journal
Vol. 98-B, Issue 1_Supple_A | Pages 116 - 119
1 Jan 2016
Petrie JR Haidukewych GJ

Instability is a common indication for early revision after both primary and revision total knee arthroplasty (TKA), accounting for up to 20% in the literature. The number of TKAs performed annually continues to climb exponentially, thus having an effective algorithm for treatment is essential. This relies on a thorough pre- and intra-operative assessment of the patient. The underlying cause of the instability must be identified initially and subsequently, the surgeon must be able to balance the flexion and extension gaps and be comfortable using a variety of constrained implants.

This review describes the assessment of the unstable TKA, and the authors’ preferred form of treatment for these difficult cases where the source of instability is often multifactorial.

Cite this article: Bone Joint J 2016;98-B(1 Suppl A):116–19.


The Bone & Joint Journal
Vol. 98-B, Issue 5 | Pages 616 - 621
1 May 2016
Teeter MG Thoren J Yuan X McCalden RW MacDonald SJ Lanting BA Naudie DDR

Aims

The purpose of the present study was to examine the long-term fixation of a cemented fixed-bearing polished titanium tibial baseplate (Genesis ll).

Patients and Methods

Patients enrolled in a previous two-year prospective trial (n = 35) were recalled at ten years. Available patients (n = 15) underwent radiostereometric analysis (RSA) imaging in a supine position using a conventional RSA protocol. Migration of the tibial component in all planes was compared between initial and ten-year follow-up. Outcome scores including the Knee Society Score, Western Ontario and McMaster Universities Arthritis Index, 12-item Short Form Health Survey, Forgotten Joint Score, and University of California, Los Angeles Activity Score were recorded.


The Bone & Joint Journal
Vol. 98-B, Issue 10 | Pages 1342 - 1346
1 Oct 2016
Spencer-Gardner L Pierrepont J Topham M Baré J McMahon S Shimmin AJ

Aims

Accurate placement of the acetabular component during total hip arthroplasty (THA) is an important factor in the success of the procedure. However, the reported accuracy varies greatly and is dependent upon whether free hand or navigated techniques are used. The aim of this study was to assess the accuracy of an instrument system that incorporates 3D printed, patient-specific guides designed to optimise the placement of the acetabular component.

Patients and Methods

A total of 100 consecutive patients were prospectively enrolled and the accuracy of placement of the acetabular component was measured using post-operative CT scans.


Bone & Joint 360
Vol. 5, Issue 5 | Pages 10 - 13
1 Oct 2016


The Bone & Joint Journal
Vol. 98-B, Issue 1_Supple_A | Pages 68 - 72
1 Jan 2016
Goodman GP Engh Jr CA

The custom triflange is a patient-specific implant for the treatment of severe bone loss in revision total hip arthroplasty (THA). Through a process of three-dimensional modelling and prototyping, a hydroxyapatite-coated component is created for acetabular reconstruction. There are seven level IV studies describing the clinical results of triflange components. The most common complications include dislocation and infection, although the rates of implant removal are low. Clinical results are promising given the challenging problem. We describe the design, manufacture and implantation process and review the clinical results, contrasting them to other methods of acetabular reconstruction in revision THA.

Cite this article: Bone Joint J 2016;98-B(1 Suppl A):68–72.


Bone & Joint 360
Vol. 5, Issue 5 | Pages 13 - 17
1 Oct 2016


Bone & Joint 360
Vol. 5, Issue 2 | Pages 31 - 33
1 Apr 2016


Bone & Joint Research
Vol. 5, Issue 11 | Pages 586 - 593
1 Nov 2016
Rakhra KS Bonura AA Nairn R Schweitzer ME Kolanko NM Beaule PE

Objectives

The purpose of this study was to compare the thickness of the hip capsule in patients with surgical hip disease, either with cam-femoroacetabular impingement (FAI) or non-FAI hip pathology, with that of asymptomatic control hips.

Methods

A total of 56 hips in 55 patients underwent a 3Tesla MRI of the hip. These included 40 patients with 41 hips with arthroscopically proven hip disease (16 with cam-FAI; nine men, seven women; mean age 39 years, 22 to 58) and 25 with non-FAI chondrolabral pathology (four men, 21 women; mean age 40 years, 18 to 63) as well as 15 asymptomatic volunteers, whose hips served as controls (ten men, five women; mean age 62 years, 33 to 77). The maximal capsule thickness was measured anteriorly and superiorly, and compared within and between the three groups with a gender subanalysis using student’s t-test. The correlation between alpha angle and capsule thickness was determined using Pearson’s correlation coefficient.


The Bone & Joint Journal
Vol. 97-B, Issue 11 | Pages 1533 - 1538
1 Nov 2015
Zhang X Shao X Huang W Zhu H Yu Y

We report a new surgical technique for the treatment of traumatic dislocation of the carpometacarpal (CMC) joint of the thumb. This is a tenodesis which uses part of the flexor carpi radialis.

Between January 2010 and August 2013, 13 patients with traumatic instability of the CMC joint of the thumb were treated using this technique. The mean time interval between injury and ligament reconstruction was 13 days (0 to 42). The mean age of the patients at surgery was 38 years: all were male.

At a mean final follow-up of 26 months (24 to 29), no patient experienced any residual instability. The mean total palmar abduction of the CMC joint of the thumb was 61° and the mean radial abduction 65° The mean measurements for the uninjured hand were 66° (60° to 73°) and 68° (60° to 75°), respectively. The mean Kapandji thumb opposition score was 8.5° (8° to 9°). The mean pinch and grip strengths of the hand were 6.7 kg (3.4 to 8.2) and 40 kg (25 to 49), respectively. The mean Disabilities of the Arm, Shoulder, and Hand questionnaire score was 3 (1 to 6). Based on the Smith and Cooney score, we obtained a mean score of 85 (75 to 95), which included four excellent, seven good, and two fair results.

Our technique offers an alternative method of treating traumatic dislocation of the CMC joint of the thumb: it produces a stable joint and acceptable hand function.

Cite this article: Bone Joint J 2015;97-B:1533–8.


The Bone & Joint Journal
Vol. 98-B, Issue 1 | Pages 97 - 101
1 Jan 2016
Jaffray DC Eisenstein SM Balain B Trivedi JM Newton Ede M

Aims

The authors present the results of a cohort study of 60 adult patients presenting sequentially over a period of 15 years from 1997 to 2012 to our hospital for treatment of thoracic and/or lumbar vertebral burst fractures, but without neurological deficit.

Method

All patients were treated by early mobilisation within the limits of pain, early bracing for patient confidence and all progress in mobilisation was recorded on video. Initial hospital stay was one week. Subsequent reviews were made on an outpatient basis.


Bone & Joint 360
Vol. 5, Issue 5 | Pages 2 - 7
1 Oct 2016
Forward DP Ollivere BJ Ng JWG Coughlin TA Rollins KE

Rib fracture fixation by orthopaedic and cardiothoracic surgeons has become increasingly popular for the treatment of chest injuries in trauma. The literature, though mainly limited to Level II and III evidence, shows favourable results for operative fixation. In this paper we review the literature and discuss the indications for rib fracture fixation, surgical approaches, choice of implants and the future direction for management. With the advent of NICE guidance and new British Orthopaedic Association Standards for Trauma (BOAST) guidelines in production, the management of rib fractures is going to become more and more commonplace.


The Bone & Joint Journal
Vol. 98-B, Issue 10_Supple_B | Pages 28 - 33
1 Oct 2016
Lum ZC Lombardi AV Hurst JM Morris MJ Adams JB Berend KR

Aims

Since redesign of the Oxford phase III mobile-bearing unicompartmental knee arthroplasty (UKA) femoral component to a twin-peg design, there has not been a direct comparison to total knee arthroplasty (TKA). Thus, we explored differences between the two cohorts.

Patients and Methods

A total of 168 patients (201 knees) underwent medial UKA with the Oxford Partial Knee Twin-Peg. These patients were compared with a randomly selected group of 177 patients (189 knees) with primary Vanguard TKA. Patient demographics, Knee Society (KS) scores and range of movement (ROM) were compared between the two cohorts. Additionally, revision, re-operation and manipulation under anaesthesia rates were analysed.


Bone & Joint 360
Vol. 4, Issue 6 | Pages 18 - 19
1 Dec 2015

The December 2015 Shoulder & Elbow Roundup360 looks at:


The Bone & Joint Journal
Vol. 97-B, Issue 5 | Pages 681 - 688
1 May 2015
Wagener ML de Vos MJ Hannink G van der Pluijm M Verdonschot N Eygendaal D

Unlinked, linked and convertible total elbow arthroplasties (TEAs) are currently available. This study is the first to report the clinical results of the convertible Latitude TEA. This was a retrospective study of a consecutive cohort of 63 patients (69 primary TEAs) with a mean age of 60 years (23 to 87). Between 2006 and 2008 a total of 19 men and 50 women underwent surgery. The mean follow-up was 43 months (8 to 84). The range of movement, function and pain all improved six months post-operatively and either continued to improve slightly or reached a plateau thereafter. The complication rate is similar to that reported for other TEA systems. No loosening was seen. Remarkable is the disengagement of the radial head component in 13 TEAs (31%) with a radial head component implanted.

Implantation of both the linked and the unlinked versions of the Latitude TEA results in improvement of function and decreased pain, and shows high patient satisfaction at mid-term follow-up.

Cite this article: Bone Joint J 2015; 97-B:681–8.


The Bone & Joint Journal
Vol. 98-B, Issue 1 | Pages 81 - 87
1 Jan 2016
Miska M Findeisen S Tanner M Biglari B Studier-Fischer S Grützner PA Schmidmaier G Moghaddam A

Methods

Between 2005 and 2012, 50 patients (23 female, 27 male) with nonunion of the humeral shaft were included in this retrospective study. The mean age was 51.3 years (14 to 88). The patients had a mean of 1.5 prior operations (sd 1.2;1 to 8).

All patients were assessed according to a specific risk score in order to devise an optimal and individual therapy plan consistent with the Diamond Concept. In 32 cases (64%), a change in the osteosynthesis to an angular stable locking compression plate was performed. According to the individual risk an additional bone graft and/or bone morphogenetic protein-7 (BMP-7) were applied.

Results

A successful consolidation of the nonunion was observed in 37 cases (80.4%) with a median healing time of six months (IQR 6). Younger patients showed significantly better consolidation. Four patients were lost to follow-up. Revision was necessary in a total of eight (16%) cases. In the initial treatment, intramedullary nailing was most common.