The Gamma nail was designed to treat unstable intertrochanteric and subtrochanteric fractures. The device was developed after cadaver studies and has been used clinically since February 1985 in a total of 421 patients. The results in 123 patients treated by the third version of this design are reported. The Gamma nail transmits weight closer to the calcar than does the dynamic hip screw and it has greater mechanical strength. A semi-closed operative technique is used, with an average duration of operation of 35 minutes and little blood loss. Distal locking screws can be used to maintain rotational stability, and can be inserted without the use of an image intensifier. Results showed satisfactory fracture union with little loss of position, even in comminuted fractures. Operative complications were few, but included fractures of the base of the greater trochanter. The most important postoperative complication, seen in one case, was fracture of the shaft of the
We compared two methods of reconstruction of the abductor mechanism in 15 patients after prosthetic replacement of the upper
We report a prospective study of the use of intramedullary bone blocks to improve the fixation of a matt-finish femoral stem in Charnley low-friction arthroplasties. There were 379 patients (441 hips), but at a minimum follow-up of ten years there were 258 arthroplasties in 221 patients including some which had been revised. The mean age at surgery was 41 years (17 to 51) and the mean follow-up was 13.4 years (1 to 20 including the early revisions). Nine stems (3.5%) had been revised for aseptic loosening, but there were no stem fractures. Survivorship of stems was 99.2% at ten years and 94.35% at 15 and 20 years. We found that the patient’s gender, the position of the stem and the experience of the surgeon all influenced the outcome. Our findings suggest that using our method of stem fixation, follow-up of over 11 years was needed to reveal the effects of endosteal cavitation of the
We assessed factors which may affect union in 32 patients with nonunion of a fracture of the diaphysis of the
Bilateral venography was performed between 12 and 15 days after total hip replacement in 745 consecutive patients, all of whom had heparin prophylaxis. Of these, 81 patients (10.8%) showed evidence of recent deep vein thrombosis: 23 (3%) distal, 44 (5.9%) isolated proximal, five (0.7%) both proximal and distal, and nine (1.2%) extensive thrombosis from calf to thigh. Compared with previous reports heparin appeared to have reduced the number of distal and contralateral thromboses, but was far less effective in reducing proximal femoral thrombosis. In a cadaver study, the femoral veins were inspected during simulated total hip replacement by either an anterior or a posterior approach. In every case the femoral vein became kinked or folded in the thigh position imposed during the preparation of the
A review was conducted of the records of fifty-five children who were admitted to the Hospital for Sick Children in Toronto between 1955 and 1975 with a diagnosis of Volkmann's contracture in fifty-eight limbs. Ten patients had been transferred to this hospital with established ischaemia after Bryant's traction for a fractured
Children with congenital focal deficiency of the proximal
1. Fifteen patients who had had osteomyelitis of the lower
1. Diametric growth and organisation of the epiphysial cartilage plate have been studied by microradiography of human bone and autoradiography of the epiphysial plate in growing rabbits, using sulphur. 35. These investigations were supplemented by a radiographic study of four patients with dyschondroplasia in whom the progress of the characteristic epiphysial defects were traced during several years' growth. 2. A perichondrial sheath of bone, at the junction of the epiphysial plate with the metaphysis, was demonstrated by microradiography of the distal end of the human
1. Cancellous bone cubes from calf and man were deproteinised with hydrogen peroxide and with ethylenediamine. 2. Long bones were removed aseptically from sheep, stored in the bone bank and used for cancellous homografts. 3. Holes were drilled in the upper part of the tibia or ulna or in the lower part of the
The aims of this study were to determine whether the administration of anti-inflammatory and antifibrotic agents affect the proliferation, viability, and expression of markers involved in the fibrotic development of the fibroblasts obtained from arthrofibrotic tissue Dexamethasone, diclofenac, and decorin, in different concentrations, were employed to treat fibroblasts from arthrofibrotic tissue (AFib). Cell proliferation was measured by DNA quantitation, and viability was analyzed by Live/Dead staining. The levels of procollagen type I N-terminal propeptide (PINP) and procollagen type III N-terminal propeptide (PIIINP) were evaluated with enzyme-linked immunosorbent assay (ELISA) kits. In addition, the expressions of fibrotic markers were detected by real-time polymerase chain reaction (PCR). Fibroblasts isolated from healthy tissue (Fib) served as control. Further, a rabbit model of joint contracture was used to evaluate the antifibrotic effect of the three different agents.Objectives
Methods
We describe a new technique for examining the infant hip using ultrasound. Both hips are imaged simultaneously via an anterior approach. The examination can be done with the hip either extended or flexed and abducted. The method has three advantages: 1) since both hips are imaged simultaneously, lines can be drawn to assist in determining the relationship between the femoral head and the pelvis; 2) proximal, anteroposterior and lateral displacement of the femoral head can all be demonstrated; 3) the method is applicable to the infant in a harness or a plaster cast to demonstrate maintenance of reduction of a dislocated hip. The usual direction of dislocation of the femoral head was anterior and lateral. Proximal migration was also observed in cases with more severe dislocation. In flexion, the dislocated head of the
To evaluate interobserver reliability of the Orthopaedic Trauma
Association’s open fracture classification system (OTA-OFC). Patients of any age with a first presentation of an open long
bone fracture were included. Standard radiographs, wound photographs,
and a short clinical description were given to eight orthopaedic
surgeons, who independently evaluated the injury using both the
Gustilo and Anderson (GA) and OTA-OFC classifications. The responses
were compared for variability using Cohen’s kappa.Aims
Patients and Methods
Calcium sulphate (CaSO4) is a resorbable material
that can be used simultaneously as filler of a dead space and as
a carrier for the local application of antibiotics. Our aim was
to describe the systemic exposure and the wound fluid concentrations
of vancomycin in patients treated with vancomycin-loaded CaSO4 as
an adjunct to the routine therapy of bone and joint infections. A total of 680 post-operative blood and 233 wound fluid samples
were available for analysis from 94 implantations performed in 87
patients for various infective indications. Up to 6 g of vancomycin
were used. Non-compartmental pharmacokinetic analysis was performed
on the data from 37 patients treated for an infection of the hip.Aims
Patients and Methods
A study was made of the mechanics of blood-bearing in a series of patients treated with a cast-brace for fracture of the distal
The features are described of seven cases of "juxtacortical" chondrosarcoma, the term introduced by Jaffe for a rare but distinct entity and now accepted in the World Health Organisation classification as preferable to the term "periosteal" chondrosarcoma. In all cases the lesion involved the shaft of a long bone, most often the
Cadaver knee joints were mounted so that life-like forces of weight-bearing were simulated. The patello-femoral contact areas were defined under load throughout the range of movement by the dye method. During movement from extension to 90 degrees of flexion a band of contact sweeps across the patella from inferior to superior pole, but the odd facet makes no contact. At about 135 degrees of flexion separate medial and lateral contact areas form, the medial one limited to the odd facet. From extension to 90 degrees of flexion the patella holds the quadriceps tendon away from the
1. A family is described of which several members in four generations suffered epiphysial growth disturbances of an unusual kind in the capital epiphyses of the
To assess complications and failure mechanisms of osteoarticular
allograft reconstructions for primary bone tumours. We retrospectively evaluated 38 patients (28 men, 74%) who were
treated at our institution with osteoarticular allograft reconstruction
between 1989 and 2010. Median age was 19 years (interquartile range
14 to 32). Median follow-up was 19.5 years (95% confidence interval
(CI) 13.0 to 26.1) when 26 patients (68%) were alive. In addition, we
systematically searched the literature for clinical studies on osteoarticular
allografts, finding 31 studies suitable for analysis. Results of
papers that reported on one site exclusively were pooled for comparison.Aims
Patients and Methods
The aim of this study was to evaluate the effects of using a
portable, accelerometer-based surgical navigation system (KneeAlign2)
in total knee arthroplasty (TKA) on the alignment of the femoral
component, and blood loss. A total of 241 consecutive patients with primary osteoarthritis
of the knee were enrolled in this prospective, randomised controlled
study. There were 207 women and 34 men. The mean age of the patients
was 74.0 years (57 to 89). The KneeAlign2 system was used for distal
femoral resection in 121 patients (KA2 group) and a conventional intramedullary
femoral guide was used in 120 patients (IM group).Aims