The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 5 | Pages 787 - 792
1 Sep 1996
Wachtl SW Sennwald GR

We treated 43 patients (38 women and 5 men) with osteoarthritis of the basal joint of the thumb by non-cemented arthroplasty of the first carpometacarpal joint as described by Ledoux. The probability of a patient avoiding revision for 12 months was 62% and for 16 months 59%. The indications for revision were aseptic loosening in 83% and luxation in 17%. The surviving prostheses were reviewed clinically and radiologically at a mean follow-up of 25.3 months. Pain on loading, movement or at rest was seen in 75% of the patients. There was significant reduction in the range of movement of the trapeziometacarpal joint and of wrist strength. Radiological assessment showed significant subsidence of the stem in the first metacarpal and migration of the cup, with the stem loose in 15% and the cup in 46%. We no longer recommend this method of joint replacement


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 4 | Pages 572 - 576
1 Jul 1993
Knight D Rymaszewski L Amis A Miller J

Compression testing of cadaver specimens showed that excision of the radial head allowed proximal radial displacement. The insertion of a metallic radial head restored normal mechanics, while a silicone rubber implant did not. We reviewed 31 of 36 comminuted fractures of the radial head, 21 associated with dislocation or ulnar fracture, which had been treated by primary replacement with a Vitallium prosthesis. At a mean follow-up of 4.5 years, there was reliable restoration of stability and prevention of proximal radial migration. There had been no dislocations or prosthetic failures, but two implants had been removed for loosening. The prosthesis is recommended for use as a spacer to stabilise the elbow after severe injuries while the soft tissues heal


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 6 | Pages 831 - 839
1 Nov 1992
Langkamer V Case C Heap P Taylor A Collins C Pearse M Solomon L

The production of particulate wear debris is a recognised complication of joint arthroplasty, but interest has concentrated on local tissue reactions and a possible association with implant loosening. The fate of wear products in the body remains unknown, although some of the metals used in the construction of orthopaedic implants are known to have toxic and oncogenic properties. We report histological and electron-microscopic evidence from two cases which shows that metallic debris can be identified in the lymphoreticular tissues of the body distant from the hip some years after joint replacement. The increase in the use of total arthroplasty in younger patients, the development of new alloys and the use of porous coatings must raise concern for the long-term effects of the accumulation of wear debris in the body


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 5 | Pages 844 - 848
1 Sep 1997
Kobayashi A Freeman MAR Bonfield W Kadoya Y Yamac T Al-Saffar N Scott G Revell PA

Our aim was to analyse the influence of the size, shape and number of particles on the pathogenesis of osteolysis. We obtained peri-implant tissues from 18 patients having revision surgery for aseptically loosened Freeman total knee replacements (10), Charnley total hip replacements (3) and Imperial College/London Hospital double-cup surface hip replacements (5). The size and shape of the polyethylene particles were characterised using SEM and their concentration was calculated. The results were analysed with reference to the presence of radiological osteolysis. The concentration of polyethylene particles in 6 areas with osteolysis was significantly higher than that in 12 areas without osteolysis. There were no significant differences between the size and shape of the particles in these two groups. We conclude that the most critical factor in the pathogenesis of osteolysis is the concentration of polyethylene particles accumulated in the tissue


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 6 | Pages 946 - 953
1 Nov 1998
Gill TJ Sledge JB Müller ME

Patients who had a revision total hip arthroplasty using the Bürch-Schneider anti-protrusio cage (APC) by a single surgeon have been reviewed after a minimum of five years. There were 63 operations in 58 patients with an average age of 63 years (41 to 83) at the time of revision. At an average follow-up of 8.5 years (5 to 18), 15 patients (25.9%) rated their results as excellent, 38 (65.5%) as good, and five (8.6%) as fair. Five further revisions of the acetabular prosthesis were required, three due to aseptic loosening, one for recurrent dislocation and one due to sepsis. Of the remainder, one was definitely loose, two probably loose, and 12 possibly so. Impressive augmentation of bone stock can be achieved with the anti-protrusio cage, while enabling the hip to be centred in its anatomical position


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 4 | Pages 545 - 550
1 Aug 1987
Roberts J Finlayson D Freeman P

We present the results of 506 consecutive Howse hip arthroplasties with a minimum follow-up of 10 years. The mortality within one month of surgery was 0.79%. The early dislocation rate was 1.38%, two hips requiring revision. Nine hips developed deep sepsis (1.78%), eight of which required revision. At 10 years 42 hips (8.3%) had required revision, including 14 with aseptic acetabular loosening and 11 with femoral stem fractures. We feel that as judged by the dislocation rate and the need for subsequent revision, the Howse arthroplasty is an acceptable form of total hip replacement, particularly in the older patient and in those requiring total replacement for femoral neck fractures


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 2 | Pages 186 - 188
1 Feb 2007
Rodriguez-Merchan EC

The results of primary total knee replacement performed on a group of haemophiliac patients in a single institution by the same surgeon using the same surgical technique and prosthesis are reported. A total of 35 primary replacements in 30 patients were carried out between 1996 and 2005 and were reviewed retrospectively. The mean age of the patients was 31 years (24 to 42) and the mean follow-up was for 7.5 years (1 to 10). There were 25 patients with haemophilia A and five with haemophilia B. The HIV status and CD4 count were recorded, and Knee Society scores determined. Two patients had inhibitors to the deficient coagulation factor. There were no early wound infections and only one late deep infection which required a two-stage revision arthroplasty, with a good final result. The incidence of infection in HIV-positive and negative patients was thus similar. One knee in a patient with inhibitor had excessive bleeding due to a pseudoaneurysm which required embolisation. The results were excellent in 27 knees (77%), good in six (17%) and fair in two (6%). The survival rate at 7.5 years taking removal of the prosthesis for loosening or infection as the end-point was 97%. The mechanical survival of total knee replacements in haemophiliacs is very good. Our results confirm that this is a reproducible procedure in haemophilia, even in HIV-positive patients with a CD4 count > 200 mm. 3. and those with inhibitors. Our rate of infection was lower than previously reported. This could be due to better control of the HIV status with highly active anti-retroviral therapy and the use of antibiotic-loaded cement


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 2 | Pages 218 - 222
1 Mar 1986
Ruddlesdin C Ansell B Arden G Swann M

The results of 75 total hip replacements in 42 children with juvenile chronic arthritis are reported after a mean follow-up of 5.4 years. Their ages ranged from 11 to nearly 17 years at operation and many had active disease. Severe pain and marked stiffness of the hips were limiting their independence. At least half of the children were still growing and continued to grow after operation. The patients were carefully selected and gratifying results were obtained, but pre-operative assessment and overall supervision by a rheumatologist are important. Technical difficulties related to the size and maldevelopment of the hip are discussed. There was no infection and the single case of loosening of a femoral component after nine years has been successfully revised


The Journal of Bone & Joint Surgery British Volume
Vol. 47-B, Issue 2 | Pages 354 - 363
1 May 1965
Charnley J

It has been shown by mechanical analysis that by using cement to bond the stem of a femoral head prosthesis to bone two advantages are obtained when the conditions are compared with conventional methods. 1. "Fretting" between the implant and the living bone is eliminated. This source of persistent relative movement is probably the most important starting point for the progressive loosening of weight-bearing implants. 2. When cement is used the bond with the bone is exposed to stresses which are of an order three hundred times less than the shear strength of bone. The conventional prostheses expose the bond to compressive stresses which are near to the failure limits of the compressive strength of bone, especially in elderly patients with atrophic cortical bone in the femoral neck


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 2 | Pages 267 - 272
1 Mar 1998
Morscher EW Hefti A Aebi U

One concern about the fixation of HA-coated implants is the possible disintegration of the surface, with the migration of HA granules into the joint space, producing third-body wear. We report a study of six revisions of HA-coated polyethylene RM cups at 9 to 14 years after successful primary arthroplasty. In all six hips, we found HA granules embedded in the articulating surface of the polyethylene, with abrasive wear of the cup and the metal femoral head. The cup had loosened in four hips and three showed severe osteolysis of the proximal femur. Third-body wear due to HA particles from implant coating may produce severe clinical problems with few early warning signs. Further clinical, radiological and histological observations are needed to determine the possible incidence of this late complication in the various types of coating of a variety of substrates


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 6 | Pages 902 - 907
1 Nov 1991
Llinas A Sarmiento A Ebramzadeh E Gogan W McKellop H

We compared the radiographic results of secondary total hip replacements, 99 following failed uncemented hemiarthroplasties and 21 following failed mould arthroplasties, with those of 825 primary cemented total hip replacements. The probability of occurrence of a number of radiological changes over time was calculated using survival analysis. The mean follow-up was 7.6 years (range one month to 20 years). The performance of the secondary total hip replacements varied with the preceding implant and was different for acetabular and femoral components. The incidence of radiological loosening was higher for femoral components implanted after failed hemiarthroplasties and for acetabular components after failed mould arthroplasties. However, the incidence of continuous radiolucent lines was lower for the acetabular components of converted hemiarthroplasties than for the primary replacements


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 5 | Pages 784 - 787
1 Sep 1990
Franzen H Nilsson L Stromqvist B Johnsson R Herrlin K

We studied the rate of revision in 84 consecutive total hip replacements performed for failed osteosynthesis of femoral neck fractures and compared it with that for primary arthroplasty for osteoarthritis. The age and sex adjusted risk of prosthetic failure was 2.5 times higher after failure of fixation, but all the excess risk was in patients over 70 years of age. There were radiographic signs of loosening of the femoral component at five to 12 years after secondary arthroplasty in six of 33 survivors. In general, the results of secondary replacement were no worse than those obtained after primary arthroplasty for femoral neck fracture. We consider that internal fixation should be the primary procedure: total hip replacement is a safe secondary procedure when osteosynthesis fails


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 1 | Pages 135 - 139
1 Jan 1997
Lerouge S Huk O Yahia L Witvoet J Sedel L

We made a semiquantitative study of the comparative histology of pseudomembranes from 12 loose cemented ceramic-ceramic and 18 metal-polyethylene total hip replacements. We found no significant difference in cellular reaction between the two groups, but there was a major difference in the origin of the particulate debris. In the metal-polyethylene group, polyethylene of articular origin was predominant, while in the ceramic-ceramic group the cellular reaction appeared to be a response to zirconia ceramic particles used to opacify cement used for fixation. Isolation and characterisation of the debris showed that the zirconia particles formed the greatest proportion (76%) in ceramic-ceramic hips, while alumina debris of articular origin formed only 12%. Our study has indicated that aseptic loosening of ceramic cups is not due to a response to debris generated at the articular interface, but to mechanical factors which lead to fragmentation of the cement


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 5 | Pages 737 - 741
1 Nov 1984
Rydholm U Tjornstrand B Pettersson H Lidgren L

Fifteen patients with rheumatoid arthritis had 19 elbow arthroplasties with the Wadsworth type of surface replacement prosthesis. After a follow-up period averaging 30 months, 11 patients with 15 elbow arthroplasties were entirely satisfied with their freedom from pain and range of movement. Radiologically, however, the humeral component was loose in 10 of the 19 elbows and the ulnar component in 5. Two patients had reoperation, one to remove a prosthesis for early deep infection and one to exchange a humeral component which was loose. The risk of mechanical loosening is reduced by accurate positioning of the humeral component, but there is a high potential for failure. Changes in the design of the prosthesis and better instrumentation for alignment of the components are desirable. Prosthetic replacement of the elbow should still be regarded as experimental


The Journal of Bone & Joint Surgery British Volume
Vol. 60-B, Issue 3 | Pages 320 - 326
1 Aug 1978
Attenborough C

The stabilised gliding knee prosthesis is a compromise between hinged joints and condylar prostheses. It is a two-piece implant designed to allow normal gliding movements of flexion and extension and which, stabilised by a connecting rod between the femoral and tibial components, allows a designed laxity of rotation and lateral movements. A modification of the original femoral component is described. Two hundred and forty-five knee replacement operations have been done between January 1973 and September 1977 and the results are reported. The results using this prosthesis are at least equal to those using hinged or condylar prostheses. So far there has been no case of spontaneous loosening of the components and the implant can be used in patients who, because of severe deformities and instability, are unsuitable for condylar prostheses


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 5 | Pages 796 - 801
1 Sep 1996
Kiss J Murray DW Turner-Smith AR Bithell JF Bulstrode CJ

We studied the migration of 58 cemented Hinek femoral components for total hip replacement,using roentgen stereophotogrammetric analysis over four years. The implants migrated faster during the first year than subsequently, and the pattern of migration in the second period was very different. During the first year they subsided, tilted into varus and internally rotated. After this there was slow distal migration with no change in orientation. None of the prostheses has yet failed. The early migration is probably caused by resorption of bone damaged by surgical trauma or the heat generated by the polymerisation of bone cement. Later migration may be due to creep in the bone cement or the surrounding fibrous membrane. The prosthesis which we studied allows the preservation of some of the femoral neck, and comparison with published migration studies of the Charnley stem suggests that this decreases rotation and may help to prevent loosening


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 4 | Pages 652 - 657
1 Jul 1996
Abudu A Carter SR Grimer RJ

Improvement in the life expectancy of patients with primary bone tumours has led to increased emphasis on limb salvage and preservation of function. Between 1979 and 1994 we used custom-made endoprostheses in 18 patients to reconstruct diaphyseal defects after excision of primary bone tumours. The mean age at operation was 26 years (9 to 64) and the median follow-up 65 months (6 to 188). Fifteen patients have survived and are free from local or metastatic disease. Local recurrence developed in one patient. Using the modified Enneking functional scoring system, 77% of the patients achieved 80% or more of their premorbid functional capability. Mechanical loosening, limb shortening and secondary osteoarthritis were the main complications. There were no infections. We conclude that diaphyseal endoprostheses offer a good clinical and functional outcome in the lower limb


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 4 | Pages 593 - 597
1 May 2001
Kamikawa K Harada Y Nagata K Moriya H

Sterilisation by gamma irradiation in the presence of air causes free radicals generated in polyethylene (PE) to react with oxygen, which could lead to loss of physical properties and reduction in fatigue strength. Tissue retrieved from failed total hip replacements often has large quantities of particulate PE and most particles associated with peri-implant osteolysis are oxidised. Consequently, an understanding of the cellular responses of oxidised PE particles may lead to clarification of the pathogenesis of osteolysis and aseptic loosening. We have used the agarose system to demonstrate the differential effects of oxidised and non-oxidised PE particles on the release of proinflammatory products such as interleukin-1β (IL-1β), IL-6, and tumour necrosis factor-α (TNF-α) from monocytes/ macrophages (M/M). Oxidised PE particles were shown to stimulate human M/M to phagocytose and to release cytokines. Oxidation may alter the surface chemistry of the particles and enhance the response to specific membrane receptors on macrophages, such as scavenger-type receptors


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 4 | Pages 557 - 561
1 Jul 1995
Harper G Bull T Cobb A Bentley G

We report a high rate of failure of the Ring polyethylene cementless cup caused largely by granulomatous osteolysis. We have reviewed 126 prostheses inserted from 1986 to 1992 at from 11 to 90 months after surgery. There was radiological evidence of osteolytic granulomas adjacent to the external surface of the cup in 32%, appearing on average at three years from operation. In a subgroup of 59 prostheses followed for at least four years the incidence of such changes was 54%. A total of 27 cups (22%) have required revision, 21 for granulomatous loosening at an average follow-up of five years. In the retrieved prostheses there was obvious polyethylene abrasion and histological examination confirmed the presence of polyethylene wear debris. We found no significant correlation of osteolysis with cup size, although smaller cups were predominant among those having revision


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 2 | Pages 173 - 177
1 Mar 1989
Rehnberg L Olerud C

We measured the stability of fixation in femoral neck fractures treated with von Bahr screws, investigated the influence of impaction and correlated peroperative stability with the clinical results. Stability was measured at operation using a metal probe fitted with strain gauges. Its tip was anchored in the subchondral bone of the femoral head and its lateral end was fixed in the lateral femoral cortex. The shearing force produced by longitudinal compression applied to the foot of the operated leg was recorded. The results in 41 consecutive patients all followed for 30 months, showed that fractures with early loosening or nonunion had all had significantly poorer stability than the fractures that had healed. Impaction improved stability in only 23 out of the 41 fractures; in the others stability had deteriorated or was unchanged