Advertisement for orthosearch.org.uk
Results 1461 - 1480 of 2714
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 56-B, Issue 3 | Pages 551 - 559
1 Aug 1974
Tuli SM Brighton CT Morton HE Clark LW

1. Chronic tuberculous osseous lesions were induced consistently in eight- to ten-week-old unvaccinated guinea-pigs by the insertion of Gelfoam impregnated with mycobacterium tuberculosis into the metaphysial region through a drill hole in the distal part of the femur. Typical tuberculous lesions developed by three weeks and many of them were followed for twelve weeks or more. 2. This experimental model establishes a reliable method of producing a localised lesion at a predetermined site without early death of the animal. The model is sufficiently similar to the human lesion, and may offer a reliable system for further investigations. 3. It was observed that streptomycin penetrates readily into tuberculous osseous lesions. The concentration of streptomycin found in the tuberculous lesion after a single intramuscular injection was much higher than the concentration considered sufficient to have an inhibitory effect on the human type of mycobacterium tuberculosis


The Journal of Bone & Joint Surgery British Volume
Vol. 48-B, Issue 4 | Pages 627 - 636
1 Nov 1966
Seddon HJ

1. Volkmann's ischaemia of the lower limb is more common in adults than in children and occurs with sufficient frequency after injuries of the femur, knee and leg to warrant a more determined effort to prevent it. 2. The first and most essential step is to recognise the early signs of ischaemic damage. Incision of the deep fascia may then save the threatened underlying muscle, though it may also be necessary to seek for and evacuate a haematoma beneath the muscle. When the femoral or popliteal artery is injured, exploration and repair may be imperative. 3. The treatment of established ischaemic contracture is by whatever measures are necessary to correct the deformity. These are lengthening of shortened tendons, or excision of them if they are involved in dense fibrosis at the periphery of the ischaemic mass; and excision of all totally destroyed muscle. Amputation may be necessary


The Journal of Bone & Joint Surgery British Volume
Vol. 48-B, Issue 4 | Pages 682 - 692
1 Nov 1966
Eyre-Brook AL

1. A small personal consecutive series of children with congenital dislocation or subluxation of the hip who came for treatment at the age of over three years has been reviewed. The children have been kept under review up to the age of ten years or more. 2. A number of late results are illustrated. They lead to the conclusion that open operation is indicated in all these cases and that acetabuloplasty will effectively provide stability in most, particularly when combined with osteotomy of the femur with adduction angulation and lateral rotation. 3. It is still too early to assess the value of pelvic osteotomy of the Salter (1961) or Chiari (1955) type. 4. Capsular arthroplasty appears from Trevor's (1960) considerable experience to have a valuable place in patients over six years old


The Journal of Bone & Joint Surgery British Volume
Vol. 39-B, Issue 3 | Pages 534 - 537
1 Aug 1957
Lécutier MA Smith AH

A case of fatal air embolism after Küntscher nailing of a fractured femur is described. Necropsy indicated that the only possible means of air entry was through the bone marrow. Subsequent discussion between the surgeon and the pathologist indicated that air must have been forced into the venous circulation through the marrow by repeated removal and reinsertion of nails, which allowed air to fill the punched-out marrow space when the nail was removed, the same air being forced into the marrow sinusoids when the nail was reinserted and hammered into position. This danger may be overcome 1) by allowing the site of operation to flood with blood by placing the patient in a "head up" position; 2) by flooding the operation site with saline; or 3) by assessing the calibre of nail required by radiological means rather than by trial and error


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 6 | Pages 892 - 898
1 Nov 1996
Bulstra SK Geesink RGT Bakker D Bulstra TH Bouwmeester SJM van der Linden AJ

We have investigated the use of a conically-shaped cement plug made of Polyactive (PA), a biodegradable copolymer. The flexibility and hydrogel properties were thought to facilitate occlusion of the femoral canal even when it was oval or irregular in shape. The function of the plug was first compared with that of the Thackray polyethylene model in 16 artificial plastic femora. The maximum intramedullary pressure achieved during cementing was ten times higher with the biodegradable model. Migration or leakage of cement did not occur when the diameter of the femoral canal was equal to or smaller than the diameter of the plug. We also showed that the biodegradable properties of this implant were such that it did not require removal during revision. The new plug was tested in a pilot clinical trial. At two years only two out of 21 patients had evidence of migration or leakage of cement, probably due to a mismatch in the size of plug and femoral canal. There were no local changes in the femur


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 6 | Pages 871 - 877
1 Nov 1996
Shindo H Igarashi H Taneda H Azuma H

We have divided Severin group-V severely dysplastic hips with a false into three subtypes, based on the height and shape of the socket. We performed rotational acetabular osteotomy (RAO) in 19 hips in 17 young adults with a type-1 ‘low’ false acetabulum which had direct contact with the true acetabulum. This is a periacetabular osteotomy which gives acetabular coverage with articular cartilage and produces a nearly normal position of the head. Concomitant osteotomies of the proximal femur were carried out in 11 hips. We reviewed the patients clinically and radiologically at a mean of ten years (6 to 18) after operation. Of the 19 hips, 15 showed very good or good results. This operation is indicated in young adults with a dysplastic hip and a type-1 low false acetabulum. Subclassification of Severin group V is a convenient way of defining those patients who would benefit from the procedure


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 5 | Pages 814 - 820
1 Sep 1999
Campanacci† M Ruggieri P Gasbarrini A Ferraro A Campanacci L

We describe 100 consecutive patients with osteoid osteoma. Of the 97 who had operations, 89 were treated by intralesional excision and eight by wide resection. The three remaining patients were not operated on because the osteoid osteoma was almost painless, or was found in the pedicle of the 12th thoracic vertebra at the site of entrance of the artery of Adamkjewicz. The diagnosis was confirmed histologically in all specimens. No local recurrences were observed at a minimum follow-up of one year. All except one patient were mobilised two to four days after surgery. A precise preoperative diagnosis of the lesion is mandatory, based on clinical findings, standard radiographs, thin-section CT and a bone scan. We compared our operative technique with 247 cases in which the percutaneous technique of removal or coagulation of the nidus had been performed. The latter procedure has a less constant rate of primary cure (83% v 100%). Its principal indication appears to be for osteoid osteomas in the proximal femur and the pelvis


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 3 | Pages 427 - 430
1 May 1996
Dhillon KS Askander A Doraisamy S

Postoperative deep-vein thrombosis (DVT) is believed to be rare in Asians. We studied 88 consecutive patients in Malaysia who had operations for fracture of the proximal femur or for total hip or knee replacement. No patient had prophylaxis against DVT; bilateral ascending venography was performed between six and ten days after operation. A total of 55 patients (62.5%) showed venographic evidence of DVT. The prevalence was greatest after total knee replacement (76.5%), less after total hip replacement (64.3%) and smallest in the fracture group (50%). One patient developed symptomatic pulmonary embolism. In contrast to other reports from Asia, we found an incidence of postoperative DVT which is similar to that reported in Western populations. This suggests that the present practice of withholding routine prophylaxis against thromboembolism in Asian patients undergoing high-risk orthopaedic procedures should be reconsidered


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 3 | Pages 456 - 459
1 May 1995
Christie J Robinson C Singer B Ray D

We randomised 24 patients before they had a cemented hemiarthroplasty for hip fracture to receive either thorough or minimal saline lavage of the femoral canal. We then determined the effect in each group on the thromboembolic and cardiopulmonary responses to the pressurised insertion of cement, using transoesophageal echocardiography to show the echogenic embolic response. We found a statistically significant reduction in both the duration of the response and the number of large emboli in patients who had had thorough lavage as compared with the control group with minimal lavage. There was also less disturbance of pulmonary function, as assessed by the change in end-tidal CO2 levels and oxygen saturation, in patients who had thorough lavage. Three patients had a significant fall in blood pressure during cement insertion; all had only minimal lavage. We consider that thorough lavage should be an essential part of the preparation of the proximal femur before cement insertion


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 1 | Pages 148 - 154
1 Jan 1999
Tonino AJ Thèrin M Doyle C

We performed a histological and histomorphometric examination in five cadaver specimens of the femoral and acetabular components and the associated tissue which had been recovered between 3.3 and 6.2 years after primary total hip arthroplasty (THA) using a proximal hydroxyapatite (HA)-coated titanium alloy implant. All had functioned well during the patients’ life. All the stems were fixed in the femur and showed osseointegration of both the proximal and distal parts. The amount of residual HA was greatest in the distal metaphyseal sections, indicating that the rate of bone remodelling may be the main factor causing loss of HA. The level of activity of the patient was the only clinical factor which correlated with loss of coating. The percentage of bone-implant osseointegration was almost constant, regardless of the amount of HA residue, periprosthetic bone density or the time of implantation. HA debris was seldom observed and if present did not cause any adverse or inflammatory reaction. Partial debonding did occur in one case as a result of a polyethylene-induced inflammatory reaction


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 2 | Pages 207 - 209
1 Mar 1993
Vangsness C DeCampos J Merritt P Wiss D

We studied 47 patients with closed, displaced, diaphyseal fractures of the femur caused by blunt trauma, to determine the incidence of associated knee injuries, particularly of the meniscus. After femoral nailing, all patients had an examination under anaesthesia and an arthroscopy. There were 12 medial meniscal injuries (5 tears) and 13 injuries of the lateral meniscus (8 tears). Ten of the 13 tears were in the posterior third of the meniscus, and two patients had tears of both menisci. Synovitis was common at the meniscal attachments. Complex and radial tears were more common than peripheral or bucket-handle tears. Examination under anaesthesia revealed ligamentous laxity in 23 patients (49%), but meniscal injuries had a similar incidence in knees with and without ligament injury. Femoral shaft fractures are often associated with injuries to the ipsilateral knee, and a high index of suspicion is necessary to identify these lesions


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 3 | Pages 345 - 351
1 May 1992
Leung K So W Shen W Hui P

The Gamma nail was introduced for the treatment of peritrochanteric fractures with the theoretical advantage of a load-sharing femoral component which could be implanted by a closed procedure. We report a randomised prospective study of 186 fractures treated by either the Gamma nail or a dynamic hip screw. Gamma nails were implanted with significantly shorter screening times, smaller incisions, and less intraoperative bleeding. The Gamma nail group had a shorter convalescence and earlier full weight-bearing, but there was no significant difference in mortality within six months, postoperative mobility, or hip function at review. More intra-operative complications were recorded in the Gamma nail group, mainly due to the mismatching of the femoral component of the nail to the small femurs of Chinese people. Use of a smaller modified nail reduced these complications. We conclude that with careful surgical technique and the modified femoral component, the Gamma nail is an advance in the treatment of peritrochanteric fractures


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 4 | Pages 671 - 675
1 Jul 1991
Kenwright J Albinana J

We reviewed 46 leg-shortening operations (37 femoral and nine tibial), performed by different methods, to assess the incidence of complications and permanent disability. Shortening of as much as 7.5 cm in the femur and 5 cm in the tibia was achieved in men of normal height without any loss of function. Complications were seen with all surgical techniques despite the use of modern implants. Most problems arose from inadequate stabilisation of the osteotomy. The most reliable method of femoral shortening was open subtrochanteric osteotomy with preservation of the isthmus, and fixation with an intramedullary nail locked at its proximal end. In tibial shortening, bone excision should be at the level of the flare in the lower diaphysis in order to achieve reliable bone healing. Simple intramedullary nail fixation should be supplemented with a long-leg cast for six weeks or the nail should be locked at both ends to prevent postoperative distraction or rotation


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 6 | Pages 980 - 984
1 Nov 1990
Santavirta S Hoikka V Eskola A Konttinen Y Paavilainen T Tallroth K

We describe six patients with aggressive granulomatous lesions around cementless total hip prostheses. Two patients previously had a cemented prosthesis in the same hip. The Lord prosthesis was used in five patients, the PCA in one. Both prostheses were made of chrome-cobalt alloy. Pain on weight-bearing occurred on average 3.2 years after the cementless arthroplasty, and at that time radiography revealed aggressive granulomatosis around the proximal femoral stem and the acetabular component in five of the patients; one had a large solitary granuloma in the proximal femur. Revision was performed on average 4.8 years after the cementless arthroplasty. At that time all granulomas had grown large in size; while waiting for revision operation, two femoral stem components fractured. All the granulomas showed a uniform histopathology, which included histiocytosis; the cause for these lesions was thought to be plastic debris from the acetabular socket


The Bone & Joint Journal
Vol. 100-B, Issue 4 | Pages 507 - 515
1 Apr 2018
Nnadi C Thakar C Wilson-MacDonald J Milner P Rao A Mayers D Fairbank J Subramanian T

Aims

The primary aim of this study was to evaluate the performance and safety of magnetically controlled growth rods in the treatment of early onset scoliosis. Secondary aims were to evaluate the clinical outcome, the rate of further surgery, the rate of complications, and the durability of correction.

Patients and Methods

We undertook an observational prospective cohort study of children with early onset scoliosis, who were recruited over a one-year period and followed up for a minimum of two years. Magnetically controlled rods were introduced in a standardized manner with distractions performed three-monthly thereafter. Adverse events which were both related and unrelated to the device were recorded. Ten children, for whom relevant key data points (such as demographic information, growth parameters, Cobb angles, and functional outcomes) were available, were recruited and followed up over the period of the study. There were five boys and five girls. Their mean age was 6.2 years (2.5 to 10).


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 1 | Pages 10 - 13
1 Jan 1985
Versluysen M

The prevalence and onset of pressure sores was studied in 283 patients admitted to a general hospital with either fracture of the proximal femur or for elective hip surgery. Ninety patients developed pressure sores, of which 60 are reported in detail. Most were in women aged 70 or more who had been admitted with hip fractures. The majority of pressure sores started soon after admission, particularly on the day of operation, after which the numbers of new cases decreased. Half the patients had more than one pressure sore and the commonest sites were the sacrum, heels, and buttocks. The mortality in patients with pressure sores was 27% and their mean length of stay in hospital far exceeded that of other patients. The prevention of pressure sores in elderly patients requires more skill and attention than the nurse alone can offer; it demands the help of the whole orthopaedic team


The Journal of Bone & Joint Surgery British Volume
Vol. 61-B, Issue 2 | Pages 133 - 137
1 May 1979
Achterman C Kalamchi A

Ninety-seven limbs, in eighty-one patients, with a diagnosis of congenital deficiency of the fibula have been reviewed. A classification was devised to distinguish the minimal hypoplasia of the fibula (Type I) from the well-known complete absence (Type II). Congenital anomalies of the femur were present in 76 per cent of patients with Type I deficiency and in 59 per cent with Type II. The shortening of the limb was by 13 per cent in Type I and by 19 per cent in Type II, and the percentage shortening was fairly constant during growth. A detailed description of the spectrum of other congenital anomalies was found to be characteristic: for example, the ball and socket formation of the ankle, tarsal coalition and anomalies of the foot. The treatment aimed simply to equalise leg length in Type I deficiency, while amputation of the foot and the fitting of a prosthesis were necessary in Type II to obtain satisfactory function


Aims

To evaluate the hypothesis that failed osteosynthesis of periprosthetic Vancouver type B1 fractures can be treated successfully with stem revision using a transfemoral approach and a cementless, modular, tapered revision stem with reproducible rates of fracture healing, stability of the revision stem, and clinically good results.

Patients and Methods

A total of 14 patients (11 women, three men) with a mean age of 72.4 years (65 to 90) undergoing revision hip arthroplasty after failed osteosynthesis of periprosthetic fractures of Vancouver type B1 were treated using a transfemoral approach to remove the well-fixed stem before insertion of a modular, fluted titanium stem which obtained distal fixation. These patients were clinically and radiologically followed up for a mean 52.2 months (24 to 144).


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 6 | Pages 971 - 975
1 Nov 1998
McCaskie AW Deehan DJ Green TP Lock KR Thompson JR Harper WM Gregg PJ

Early implants for total knee replacement were fixed to bone with cement. No firm scientific reason has been given for the introduction of cementless knee replacement and the long-term survivorship of such implants has not shown any advantage over cemented forms. In a randomised, prospective study we have compared cemented and uncemented total knee replacement and report the results of 139 prostheses at five years. Outcome was assessed both clinically by independent examination using the Nottingham knee score and radiologically using the Knee Society scoring system. Independent statistical analysis of the data showed no significant difference between cemented and cementless fixation for pain, mobility or movement. There was no difference in the radiological alignment at five years, but there was a notable disparity in the radiolucent line score. With cemented fixation there was a significantly greater number of radiolucent lines on anteroposterior radiographs of the tibia and lateral radiographs of the femur. At five years, our clinical results would not support the use of the more expensive cementless fixation whereas the radiological results are of unknown significance. Longer follow-up will determine any changes in the results and conclusions


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 6 | Pages 869 - 871
1 Nov 1993
Lieberman Moeckel B Evans B Salvati E Ranawat C

We reviewed 19 revision hip arthroplasties in which the new femoral component had been recemented into the old, intact cement mantle. The mean time from the first operation to revision was 64 months and the average follow-up was 59 months. There were 7 excellent, 11 good, and one fair result. No femoral component had been revised for loosening and all the stems appeared radiographically stable. Complications included intraoperative perforation of the femur on two occasions and one dislocation. The use of the cement-within-cement technique requires that the old cement surface be dry and roughened to increase the surface area and that the cement be injected in the liquid phase to prevent lamination. The indications for this technique include a broken stem with an intact distal cement mantle, the removal of a femoral component for revision of a loose cup to improve exposure and/or increase offset, recurrent dislocation secondary to component malposition, and debonding of the femoral component within an intact cement mantle