The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 7 | Pages 896 - 902
1 Jul 2005
Hernigou P Poignard A Manicom O Mathieu G Rouard H


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 4 | Pages 421 - 426
1 Apr 2006
Pountos I Jones E Tzioupis C McGonagle D Giannoudis PV


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 6 | Pages 762 - 765
1 Jun 2009
Toros T Karabay N Özaksar K Sugun TS Kayalar M Bal E

We prospectively studied 26 consecutive patients with clinically documented sensory or motor deficiency of a peripheral nerve due to trauma or entrapment using ultrasound, and in 19 cases surgical exploration of the nerves was undertaken. The ultrasonographic diagnoses were correlated with neurological examination and the surgical findings. Reliable visualisation of injured nerves on ultrasonography was achieved in all patients. Axonal swelling and hypoechogenity of the nerve was diagnosed in 15 cases, loss of continuity of a nerve bundle in 17, the formation of a neuroma of a stump in six, and partial laceration of a nerve with loss of the normal fascicular pattern in five. The ultrasonographic findings were confirmed at operation in those who had surgery.

Ultrasound may be used for the evaluation of peripheral nerve injuries in the upper limb. High-resolution ultrasound can show the exact location, extent and type of lesion, yielding important information that might not be obtainable by other diagnostic aids.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 5 | Pages 726 - 736
1 May 2010
Hee HT Ismail HD Lim CT Goh JCH Wong HK

Although success has been achieved with implantation of bone marrow mesenchymal stem cells (bMSCs) in degenerative discs, its full potential may not be achieved if the harsh environment of the degenerative disc remains. Axial distraction has been shown to increase hydration and nutrition. Combining both therapies may have a synergistic effect in reversing degenerative disc disease. In order to evaluate the effect of bMSC implantation, axial distraction and combination therapy in stimulating regeneration and retarding degeneration in degenerative discs, we first induced disc degeneration by axial loading in a rabbit model.

The rabbits in the intervention groups performed better with respect to disc height, morphological grading, histological scoring and average dead cell count. The groups with distraction performed better than those without on all criteria except the average dead cell count.

Our findings suggest that bMSC implantation and distraction stimulate regenerative changes in degenerative discs in a rabbit model.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 10 | Pages 1311 - 1316
1 Oct 2008
Kim Y Kim J

The purpose of this study was to determine objectively the outcome of total knee replacement in patients with ankylosed knees.

There were 82 patients (99 knees) with ankylosed knees who underwent total knee replacement with a condylar constrained or a posterior stabilised prosthesis. Their mean age was 41.9 years (23 to 60) and the mean follow-up was for 8.9 years (6.6 to 14). Pre- and post-operative data included the Hospital for Special Surgery (HSS), the Knee Society (KS) and the Western Ontario and McMaster University Osteoarthritis index (WOMAC) scores.

The mean HSS, KS and WOMAC scores improved from 60, 53, and 79 pre-operatively to 81, 85, and 37 at follow-up. These improvements were statistically significant (p = 0.018, 0.001 and 0.014 respectively). The mean physical, social and emotional WOMAC scores also improved significantly (p = 0.032, p = 0.023 and p < 0.001 respectively). The mean satisfaction score was 8.5 (sd 1.5).

Total knee replacement gives good mid-term results in patients with ankylosed knees.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 1 | Pages 47 - 51
1 Jan 2011
Hetsroni I Lyman S Do H Mann G Marx RG

Pulmonary embolism is a serious complication after arthroscopy of the knee, about which there is limited information. We have identified the incidence and risk factors for symptomatic pulmonary embolism after arthroscopic procedures on outpatients. The New York State Department of Health Statewide Planning and Research Cooperative System database was used to review arthroscopic procedures of the knee performed on outpatients between 1997 and 2006, and identify those admitted within 90 days of surgery with an associated diagnosis of pulmonary embolism. Potential risk factors included age, gender, complexity of surgery, operating time defined as the total time that the patient was actually in the operating room, history of cancer, comorbidities, and the type of anaesthesia. We identified 374 033 patients who underwent 418 323 outpatient arthroscopies of the knee. There were 117 events of pulmonary embolism (2.8 cases for every 10 000 arthroscopies). Logistic regression analysis showed that age and operating time had significant dose-response increases in risk (p < 0.001) for a subsequent admission with a pulmonary embolism. Female gender was associated with a 1.5-fold increase in risk (p = 0.03), and a history of cancer with a threefold increase (p = 0.05).

These risk factors can be used when obtaining informed consent before surgery, to elevate the level of clinical suspicion of pulmonary embolism in patients at risk, and to establish a rationale for prospective studies to test the clinical benefit of thromboprophylaxis in high-risk patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 5 | Pages 677 - 683
1 May 2005
Calvo E Granizo JJ Fernández-Yruegas D

We prospectively evaluated 61 patients treated arthroscopically for anterior instability of the shoulder at a mean follow-up of 44.5 months (24 to 100) using the Rowe scale. Those with post-operative dislocation or subluxation were considered to be failures. Logistic regression analysis was used to identify patients at increased risk of recurrence in order to develop a suitable selection system.

The mean Rowe score improved from 45 pre-operatively to 86 at follow-up (p < 0.001). At least one episode of post-operative instability occurred in 11 patients (18%), although their stability improved (p = 0.018), and only three required revision. Subjectively, eight patients were dissatisfied. Age younger than 28 years, ligamentous laxity, the presence of a fracture of the glenoid rim involving more than 15% of the articular surface, and post-operative participation in contact or overhead sports were associated with a higher risk of recurrence, and scored 1, 1, 5 and 1 point, respectively. Those patients with a total score of two or more points had a relative risk of recurrence of 43% and should be treated by open surgery.


Bone & Joint 360
Vol. 1, Issue 3 | Pages 1 - 1
1 Jun 2012
Villar RN


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 10 | Pages 1339 - 1343
1 Oct 2012
Cross MB Dolan MM Sidhu GS Nguyen J Mayman DJ Su EP

The purpose of this study was to compare the amount of acetabular bone removed during hip resurfacing (HR) and cementless total hip replacement (THR), after controlling for the diameter of the patient’s native femoral head. Based on a power analysis, 64 consecutive patients (68 hips) undergoing HR or THR were prospectively enrolled in the study. The following data were recorded intra-operatively: the diameter of the native femoral head, the largest reamer used, the final size of the acetabular component, the size of the prosthetic femoral head and whether a decision was made to increase the size of the acetabular component in order to accommodate a larger prosthetic femoral head. Results were compared using two-sided, independent samples Student’s t-tests. A statistically significant difference was seen in the mean ratio of the size of the acetabular component to the diameter of the native femoral head (HR: 1.05 (sd 0.04) versus THR: 1.09 (sd 0.05); p <  0.001) and largest acetabular reamer used to the diameter of the native femoral head (HR: 1.03 (sd 0.04) versus THR: 1.09 (sd 0.05); p < 0.001). The ratios varied minimally when the groups were subdivided by gender, age and obesity. The decision to increase the size of the acetabular component to accommodate a larger femoral head occurred more often in the THR group (27% versus 9%). Despite the emphasis on avoiding damage to the femoral neck during HR, the ratio of the size of the acetabular component to the diameter of the native femoral head was larger in cementless THR than in HR.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1086 - 1089
1 Aug 2012
Magaji SA Singh HP Pandey RK

A total of 92 patients with symptoms for over six months due to subacromial impingement of the shoulder, who were being treated with physiotherapy, were included in this study. While continuing with physiotherapy they waited a further six months for surgery. They were divided into three groups based on the following four clinical and radiological criteria: temporary benefit following steroid injection, pain in the mid-arc of abduction, a consistently positive Hawkins test and radiological evidence of impingement. Group A fulfilled all four criteria, group B three criteria and group C two criteria. A total of nine patients improved while waiting for surgery and were excluded, leaving 83 who underwent arthroscopic subacromial decompression (SAD). The new Oxford shoulder score was recorded pre-operatively and at three and 12 months post-operatively.

A total of 51 patients (group A) had a significant improvement in the mean shoulder score from 18 (13 to 22) pre-operatively to 38 (35 to 42) at three months (p < 0.001). The mean score in this group was significantly better than in group B (21 patients) and C (11 patients) at this time. At one year patients in all groups showed improvement in scores, but patients in group A had a higher mean score (p = 0.01). At one year patients in groups A and B did better than those in group C (p = 0.01).

Arthroscopic SAD is a beneficial intervention in selected patients. The four criteria could help identify patients in whom it is likely to be most effective.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 11 | Pages 1519 - 1521
1 Nov 2007
Khunda A Stirrat AN Dunlop P

The proximal humerus internal locking system is an internal fixation device consisting of a low-profile plate and locking screws, which is used for the fixation of three- and four-part fractures of the proximal humerus. We describe a case in which the screws cut out of the humeral head causing injury to the axillary artery necessitating urgent removal of the implant.


Bone & Joint Research
Vol. 2, Issue 2 | Pages 41 - 50
1 Feb 2013
Cottrell JA Keshav V Mitchell A O’Connor JP

Objectives

Recent studies have shown that modulating inflammation-related lipid signalling after a bone fracture can accelerate healing in animal models. Specifically, decreasing 5-lipoxygenase (5-LO) activity during fracture healing increases cyclooxygenase-2 (COX-2) expression in the fracture callus, accelerates chondrogenesis and decreases healing time. In this study, we test the hypothesis that 5-LO inhibition will increase direct osteogenesis.

Methods

Bilateral, unicortical femoral defects were used in rats to measure the effects of local 5-LO inhibition on direct osteogenesis. The defect sites were filled with a polycaprolactone (PCL) scaffold containing 5-LO inhibitor (A-79175) at three dose levels, scaffold with drug carrier, or scaffold only. Drug release was assessed in vitro. Osteogenesis was assessed by micro-CT and histology at two endpoints of ten and 30 days.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 10 | Pages 1310 - 1315
1 Oct 2009
Ibrahim SAR Hamido F Al Misfer AK Mahgoob A Ghafar SA Alhran H

A total of 218 patients with unilateral anterior cruciate ligament deficiency were randomly assigned to one of four groups. In group A an anatomical double bundle anterior cruciate ligament reconstruction was performed; group B were treated by a single bundle using an Endobutton for femoral fixation; in group C by a single bundle using RigidFix cross pins for femoral fixation; and in group D by a single bundle using a bioabsorbable TransFix II screw for femoral fixation. For tibial fixation a bioabsorbable Intrafix interference screw was used for all the groups and the graft was fashioned from the semitendinosus and gracilis tendons in all patients. In all, 18 patients were lost to follow-up. The remaining 200 were subjected to a clinical evaluation, with assessment of the anterior drawer, Lachman’s and the pivot-shift tests, and KT-1000 arthrometer measurement. They also completed the International Knee Documentation Committee, Lysholm knee and Tegner activity scores.

At a mean of 29 months (25 to 38) follow-up there were no significant differences concerning time between injury and range of movement and Lysholm knee scores among the four groups. However, the double bundle method showed significantly better results for the pivot-shift test (p = 0.002). The KT 1000 measurements showed a mean difference between the reconstructed knee and the patients’ normal knee of 1.4 mm in the double bundle group and 2.4 mm in the single bundle group; which was statistically significant. The Lachman and anterior drawer tests also showed superior results for the double bundle method. The International Knee Documentation Committee scale showed no significant difference among the groups (p < 0.001).

On clinical evaluation the double bundle group showed less laxity than the single bundle groups. However, regardless of the technique, all knees were improved by anterior cruciate ligament reconstruction compared with their pre-operative status.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 10 | Pages 1427 - 1432
1 Oct 2012
Chassanidis CG Malizos KN Varitimidis S Samara S Koromila T Kollia P Dailiana Z

Periosteum is important for bone homoeostasis through the release of bone morphogenetic proteins (BMPs) and their effect on osteoprogenitor cells. Smoking has an adverse effect on fracture healing and bone regeneration. The aim of this study was to evaluate the effect of smoking on the expression of the BMPs of human periosteum. Real-time polymerase chain reaction was performed for BMP-2,-4,-6,-7 gene expression in periosteal samples obtained from 45 fractured bones (19 smokers, 26 non-smokers) and 60 non-fractured bones (21 smokers, 39 non-smokers). A hierarchical model of BMP gene expression (BMP-2 > BMP-6 > BMP-4 > BMP-7) was demonstrated in all samples. When smokers and non-smokers were compared, a remarkable reduction in the gene expression of BMP-2, -4 and -6 was noticed in smokers. The comparison of fracture and non-fracture groups demonstrated a higher gene expression of BMP-2, -4 and -7 in the non-fracture samples. Within the subgroups (fracture and non-fracture), BMP gene expression in smokers was either lower but without statistical significance in the majority of BMPs, or similar to that in non-smokers with regard to BMP-4 in fracture and BMP-7 in non-fracture samples. In smokers, BMP gene expression of human periosteum was reduced, demonstrating the effect of smoking at the molecular level by reduction of mRNA transcription of periosteal BMPs. Among the BMPs studied, BMP-2 gene expression was significantly higher, highlighting its role in bone homoeostasis.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 2 | Pages 237 - 244
1 Feb 2011
Berber O Amis AA Day AC

The purpose of this study was to assess the stability of a developmental pelvic reconstruction system which extends the concept of triangular osteosynthesis with fixation anterior to the lumbosacral pivot point. An unstable Tile type-C fracture, associated with a sacral transforaminal fracture, was created in synthetic pelves. The new concept was compared with three other constructs, including bilateral iliosacral screws, a tension band plate and a combined plate with screws. The pubic symphysis was plated in all cases. The pelvic ring was loaded to simulate single-stance posture in a cyclical manner until failure, defined as a displacement of 2 mm or 2°. The screws were the weakest construct, failing with a load of 50 N after 400 cycles, with maximal translation in the craniocaudal axis of 12 mm. A tension band plate resisted greater load but failure occurred at 100 N, with maximal rotational displacement around the mediolateral axis of 2.3°.

The combination of a plate and screws led to an improvement in stability at the 100 N load level, but rotational failure still occurred around the mediolateral axis. The pelvic reconstruction system was the most stable construct, with a maximal displacement of 2.1° of rotation around the mediolateral axis at a load of 500 N.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1468 - 1474
1 Nov 2012
Hill JC Archbold HAP Diamond OJ Orr JF Jaramaz B Beverland DE

Restoration of leg length and offset is an important goal in total hip replacement. This paper reports a calliper-based technique to help achieve these goals by restoring the location of the centre of the femoral head. This was validated first by using a co-ordinate measuring machine to see how closely the calliper technique could record and restore the centre of the femoral head when simulating hip replacement on Sawbone femur, and secondly by using CT in patients undergoing hip replacement.

Results from the co-ordinate measuring machine showed that the centre of the femoral head was predicted by the calliper to within 4.3 mm for offset (mean 1.6 (95% confidence interval (CI) 0.4 to 2.8)) and 2.4 mm for vertical height (mean -0.6 (95% CI -1.4 to 0.2)). The CT scans showed that offset and vertical height were restored to within 8 mm (mean -1 (95% CI -2.1 to 0.6)) and -14 mm (mean 4 (95% CI 1.8 to 4.3)), respectively.

Accurate assessment and restoration of the centre of the femoral head is feasible with a calliper. It is quick, inexpensive, simple to use and can be applied to any design of femoral component.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1448 - 1454
1 Nov 2012
Ng CY Watts AC

Bone loss involving articular surface is a challenging problem faced by the orthopaedic surgeon. In the hand and wrist, there are articular defects that are amenable to autograft reconstruction when primary fixation is not possible. In this article, the surgical techniques and clinical outcomes of articular reconstructions in the hand and wrist using non-vascularised osteochondral autografts are reviewed.


Bone & Joint 360
Vol. 1, Issue 4 | Pages 17 - 19
1 Aug 2012

The August 2012 Wrist & Hand Roundup360 looks at: the Herbert ulnar head prosthesis; the five-year outcome for wrist arthroscopic surgery; four-corner arthrodesis with headless screws; balloon kyphoplasty for Kienböck's disease; Mason Type 2 radial head fractures; local infiltration and intravenous regional anaesthesia for endoscopic carpal tunnel release; perilunate injuries; and replanting the amputated fingertip.


Bone & Joint 360
Vol. 1, Issue 4 | Pages 27 - 29
1 Aug 2012

The August 2012 Oncology Roundup360 looks at: prolonged symptom duration; peri-operative mortality and above-knee amputation; giant cell tumour of the spine; surgical resection for Ewing’s sarcoma; intercalary allograft reconstruction of the femur for tumour defects; and an induced membrane technique for large bone defects.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 10 | Pages 1403 - 1408
1 Oct 2012
Hannemann PFW Göttgens KWA van Wely BJ Kolkman KA Werre AJ Poeze M Brink PRG

The use of pulsed electromagnetic fields (PEMF) to stimulate bone growth has been recommended as an alternative to the surgical treatment of ununited scaphoid fractures, but has never been examined in acute fractures. We hypothesised that the use of PEMF in acute scaphoid fractures would accelerate the time to union by 30% in a randomised, double-blind, placebo-controlled, multicentre trial. A total of 53 patients in three different medical centres with a unilateral undisplaced acute scaphoid fracture were randomly assigned to receive either treatment with PEMF (n = 24) or a placebo (n = 29). The clinical and radiological outcomes were assessed at four, six, nine, 12, 24 and 52 weeks.

A log-rank analysis showed that neither time to clinical and radiological union nor the functional outcome differed significantly between the groups. The clinical assessment of union indicated that at six weeks tenderness in the anatomic snuffbox (p = 0.03) as well as tenderness on longitudinal compression of the scaphoid (p = 0.008) differed significantly in favour of the placebo group.

We conclude that stimulation of bone growth by PEMF has no additional value in the conservative treatment of acute scaphoid fractures.