Advertisement for orthosearch.org.uk
Results 1401 - 1420 of 2489
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 3 | Pages 391 - 395
1 May 1998
Schreurs BW Slooff TJJH Buma P Gardeniers JWM Huiskes R

We report a long-term review of 60 acetabular components revised using impacted, morsellised bone allografts and a cemented polyethylene cup. The acetabular defects were cavitary (37) or combined (23). Follow-up was for a mean 11.8 years (10 to 15). Further revision was needed in five hips, two for septic and three for aseptic loosening. The overall survival rate at 11.8 years was 90%; excluding the septic cases it was 94%. Acetabular reconstruction with impacted morsellised cancellous grafts and cement gives satisfactory long-term results


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 1 | Pages 57 - 60
1 Jan 1987
Ejsted R Olsen N

Ninety-seven revisions of total hip replacements are reviewed with a median time of observation of 47 months. Satisfactory pain relief was obtained in 86%. There were six complete failures which were reduced to three by further surgery. One hip became infected and was excised. In 12 cases the revisions were complicated by peroperative fractures and in five by dislocations. Radiographic analysis disclosed a high percentage of periarticular ossification and 25 cases of radiographic loosening of the femoral implant


Bone & Joint 360
Vol. 6, Issue 2 | Pages 10 - 13
1 Apr 2017


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 1 | Pages 124 - 127
1 Jan 1996
Watson M

A bipolar spacer was inserted for severe arthritic destruction of the shoulder in 14 patients, and followed up for a mean of 5.9 years. In one patient the operation failed because of infection. Two others required revision for loss of low-friction properties which caused loosening of the humeral component. At the end of the follow-up all the patients showed improvement. The Hospital for Special Surgery pain score had increased from 5.3 to 18.9 and the movement score from 7.5 to 20.1


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 6 | Pages 836 - 840
1 Aug 2003
Kooijman HJ Driessen APPM van Horn JR

We studied retrospectively the outcome of patellofemoral arthroplasty (PFA) using the Richards prosthesis in 51 patients (56 knees). Their mean age was 50 years (30 to 77). In 43 patients (45 knees), the American Knee Society score and the patients’ subjective judgement were assessed. Excellent or good results were obtained in 86% of cases at a mean follow-up of 17 years (15 to 21). Because of ongoing tibiofemoral osteoarthritis, two patients required a high tibial osteotomy and ten PFAs were converted to a total knee arthroplasty after a mean of 15.6 years (10 to 21). The PFAs were stable during follow-up with a loosening rate of only 2%. We conclude that a patellofemoral prosthesis is a good treatment option with successful long-term results in middle-aged patients with radiologically documented, isolated, patellofemoral osteoarthritis


Bone & Joint Research
Vol. 6, Issue 9 | Pages 542 - 549
1 Sep 2017
Arnold M Zhao S Ma S Giuliani F Hansen U Cobb JP Abel RL Boughton O

Objectives

Microindentation has the potential to measure the stiffness of an individual patient’s bone. Bone stiffness plays a crucial role in the press-fit stability of orthopaedic implants. Arming surgeons with accurate bone stiffness information may reduce surgical complications including periprosthetic fractures. The question addressed with this systematic review is whether microindentation can accurately measure cortical bone stiffness.

Methods

A systematic review of all English language articles using a keyword search was undertaken using Medline, Embase, PubMed, Scopus and Cochrane databases. Studies that only used nanoindentation, cancellous bone or animal tissue were excluded.


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 2 | Pages 307 - 309
1 Mar 1995
Went P Krismer M Frischhut B

We performed revision surgery for infected arthroplasty in 98 hips (96 patients). In 28 hips infection persisted. Of the remaining 70 hips, 61 (87%) were reviewed after a mean interval of 5.9 years (1 to 17). Infection occurred in 10% of these after three years and in 26% after ten years. The infection rate after initially successful revision for septic arthroplasty is higher than after revision for aseptic loosening and the risk of developing infection continues for many years


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 3 | Pages 374 - 380
1 May 1987
Patterson M

Since 1964, 3573 uncemented Ring total hip replacements of all types have been performed; 194 (5.4%) have required revision for infection, loosening or breakage. Of these, 102 were available for review; 81 had satisfactory results five years after operation. These results are better than many of those reported after revision of cemented hip replacements. It is suggested that the absence of cement makes revision easier because bone erosion rarely occurs


Bone & Joint 360
Vol. 6, Issue 6 | Pages 38 - 40
1 Dec 2017


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 2 | Pages 216 - 219
1 Mar 2002
Kim Y Kim J Oh S

We describe the results of total knee arthroplasty (TKA) undertaken for severe, neurosyphilitic Charcot arthropathy in ten patients (19 knees). A cemented condylar, constrained prosthesis was implanted in all but two knees. The mean follow-up was 5.2 years (5 to 6). The mean knee score before operation was 36.5 points (30 to 42) which improved to 76 points (58 to 90) after operation as judged by the Hospital for Special Surgery score. At final follow-up three knees (16%) had aseptic loosening which required salvage by an arthrodesis, six (31%) were functioning poorly and ten (53%) were satisfactory. We conclude that although Charcot arthropathy is not an absolute contraindication to total knee replacement, there is a high incidence of serious complications


Bone & Joint 360
Vol. 6, Issue 4 | Pages 25 - 29
1 Aug 2017


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 6 | Pages 865 - 869
1 Aug 2002
Wicart P Mascard E Missenard G Dubousset J

Failure of massive knee endoprostheses implanted for malignant tumours of the distal femur in children presents a difficult problem. We present the results of rotationplasty undertaken under these circumstances in four boys. They had been treated initially at a mean age of 9.5 years for a stage-IIB malignant tumour of the distal femur by resection and implantation of a massive knee endoprosthesis. After a mean period of eight years and a mean of four operative procedures, there was failure of the endoprosthesis because of aseptic loosening in two and infection in two. Function was poor with a mean Musculoskeletal Tumor Society score of 7.5/30, and considerable associated psychological problems. At a mean follow-up of 4.5 years after rotationplasty there was excellent function with a mean score of 27.5/30 and resolution of the psychological problems


Objectives

Posterior condylar offset (PCO) and posterior tibial slope (PTS) are critical factors in total knee arthroplasty (TKA). A computational simulation was performed to evaluate the biomechanical effect of PCO and PTS on cruciate retaining TKA.

Methods

We generated a subject-specific computational model followed by the development of ± 1 mm, ± 2 mm and ± 3 mm PCO models in the posterior direction, and -3°, 0°, 3° and 6° PTS models with each of the PCO models. Using a validated finite element (FE) model, we investigated the influence of the changes in PCO and PTS on the contact stress in the patellar button and the forces on the posterior cruciate ligament (PCL), patellar tendon and quadriceps muscles under the deep knee-bend loading conditions.


The Journal of Bone & Joint Surgery British Volume
Vol. 61-B, Issue 4 | Pages 445 - 450
1 Nov 1979
Vanhegan J Dabrowski W Arden G

We have reviewed 100 Attenborough total knee replacements in eighty-two patients with a follow-up of one to four years and conclude that this prosthesis has a valuable place in the surgical management of patients suffering from rheumatoid arthritis and osteoarthritis with severe involvement of the knee. In 85 per cent of these knees a good result was obtained with relief from pain, and in 77 per cent a useful range of movement with a stable knee. Only two patients with loosening and three with deep infection were seen in this series


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 6 | Pages 971 - 979
1 Nov 1990
Anthony P Gie G Howie C Ling R

Four cases are described of localised endosteal bone lysis in the femur occurring in association with cemented femoral components that were not obviously 'loose' radiologically. In each, the area of lysis was shown at operation to be related directly to a region in which there was a local defect in the cement mantle surrounding the stem. Via the space between the stem and cement, such defects provide a route through which the contents of the joint cavity may reach the endosteal surface of the femur, subsequently leading to localised bone lysis, and later to frank loosening


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 3 | Pages 375 - 377
1 Apr 2000
Inao S Matsuno T

We carried out primary cemented total hip arthroplasty (THA) on 25 hips in 21 patients with developmental dysplasia of the hip, using autogenous acetabular bone grafts. The socket was placed at the level of the true acetabulum and bone from the femoral neck was used as graft. Five hips were excluded, leaving 20 which were followed up for a mean of 12.9 years (10 to 18). The mean modified Merle d’Aubigné and Postel functional scores were 5.6 for pain, 4.3 for mobility and 4.2 for range of movement. Radiological examination showed aseptic loosening in three sockets but not in the stems. The bone grafts had united and showed no evidence of late failure


Bone & Joint 360
Vol. 6, Issue 4 | Pages 13 - 15
1 Aug 2017


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 8 | Pages 1114 - 1119
1 Nov 2003
Elke R Berli B Wagner A Morscher EW

The need for supplementary screw fixation in acetabular revisions is still widely debated. We carried out 439 acetabular revisions over an eight-year period. In 171 hips with contained or small segmental defects, the Morscher press-fit cup was used. These revisions were followed prospectively. No screws were used for additional fixation. A total of 123 hips with a mean follow-up of 7.4 years (5 to 10.5) were available for clinical and radiological review. There was no further revision of a press-fit cup for aseptic loosening. Radiological assessment revealed osteolysis in three hips. Of the original 171 hips there was cranial and medial migration of up to 6 mm at two years in 44 (26%). No further migration was seen after the second post-operative year. Acetabular revision without screws is possible with excellent medium-term results in well selected patients


The Bone & Joint Journal
Vol. 99-B, Issue 2 | Pages 276 - 282
1 Feb 2017
Mumith A Coathup M Chimutengwende-Gordon M Aston W Briggs T Blunn G

Aims

Massive endoprostheses rely on extra-cortical bone bridging (ECBB) to enhance fixation. The aim of this study was to investigate the role of selective laser sintered (SLS) porous collars in augmenting the osseointegration of these prostheses.

Materials and Methods

The two novel designs of porous SLS collars, one with small pores (Ø700 μm, SP) and one with large pores (Ø1500 μm, LP), were compared in an ovine tibial diaphyseal model. Osseointegration of these collars was compared with that of a clinically used solid, grooved design (G). At six months post-operatively, the ovine tibias were retrieved and underwent radiological and histological analysis.


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 1 | Pages 100 - 105
1 Jan 1986
Simison A Noble J Hardinge K

Of a consecutive series of 144 Attenborough knee replacements, 107 were re-examined between two and six years after operation and revealed a high incidence of complications. Wound problems were common and led to deep infection in four knees. When a patellar implant was used fracture of the patella followed in 17.5% of knees, but when the patella was not resurfaced 16% of knees developed patellofemoral pain of sufficient severity to require a further operation. In 10% of knees, definite loosening of one or both of the major components occurred