We investigated the changes seen on serial metal
artefact reduction magnetic resonance imaging scans (MARS-MRI) of
metal-on-metal
Adverse reaction to wear and corrosion debris
is a cause for concern in
The August 2012 Hip &
Pelvis Roundup. 360. looks at: whether cemented hip replacement might be bad for your health; highly cross-linked polyethylene; iHOT-33 - a new hip outcome measure; hamstring injuries;
This prospective randomised clinical trial evaluated the effect of alternatives for allogeneic blood transfusions after
The transition from shutdown of elective orthopaedic services to the resumption of pre-COVID-19 activity presents many challenges. These include concerns about patient safety, staff safety, and the viability of health economies. Careful planning is necessary to allow patients to benefit from orthopaedic care in a safe and sustainable manner. Cite this article:
Background. Approximately half of all hip fractures are displaced intracapsular fractures. The standard treatment for these fractures is either hemiarthroplasty or
The December 2012 Hip &
Pelvis Roundup. 360 . looks at: swimming against the tide with resurfacing; hip impingement surgery; the relationship between obesity and co-morbidities and joint replacement infection; cemented hips; cross-linked polyethylene notching; whether cement is necessary in oncological arthroplasty; and how
Medical comorbidities are a critical factor in the decision-making process for operative management and risk-stratification. The Hierarchical Condition Categories (HCC) risk adjustment model is a powerful measure of illness severity for patients treated by surgeons. The HCC is utilized by Medicare to predict medical expenditure risk and to reimburse physicians accordingly. HCC weighs comorbidities differently to calculate risk. This study determines the prevalence of medical comorbidities and the average HCC score in Medicare patients being evaluated by neurosurgeons and orthopaedic surgeon, as well as a subset of academic spine surgeons within both specialities, in the USA. The Medicare Provider Utilization and Payment Database, which is based on data from the Centers for Medicare and Medicaid Services’ National Claims History Standard Analytic Files, was analyzed for this study. Every surgeon who submitted a valid Medicare Part B non-institutional claim during the 2013 calendar year was included in this study. This database was queried for medical comorbidities and HCC scores of each patient who had, at minimum, a single office visit with a surgeon. This data included 21,204 orthopaedic surgeons and 4,372 neurosurgeons across 54 states/territories in the USA.Aims
Methods
Elective operating was halted during the COVID-19 pandemic to increase the capacity to provide care to an unprecedented volume of critically unwell patients. During the pandemic, the orthopaedic department at the Aneurin Bevan University Health Board restructured the trauma service, relocating semi-urgent ambulatory trauma operating to the isolated clean elective centre (St. Woolos’ Hospital) from the main hospital receiving COVID-19 patients (Royal Gwent Hospital). This study presents our experience of providing semi-urgent trauma care in a COVID-19-free surgical unit as a safe way to treat trauma patients during the pandemic and a potential model for restarting an elective orthopaedic service. All patients undergoing surgery during the COVID-19 pandemic at the orthopaedic surgical unit (OSU) in St. Woolos’ Hospital from 23 March 2020 to 24 April 2020 were included. All patients that were operated on had a telephone follow-up two weeks after surgery to assess if they had experienced COVID-19 symptoms or had been tested for COVID-19. The nature of admission, operative details, and patient demographics were obtained from the health board’s electronic record. Staff were assessed for sickness, self-isolation, and COVID-19 status.Aims
Methods
There is great variability in acetabular component
orientation following hip replacement. The aims of this study were
to compare the component orientation at impaction with the orientation
measured on post-operative radiographs and identify factors that
influence the difference between the two. A total of 67 hip replacements
(52
This combined clinical and in vitro study aimed to determine the incidence of liner malseating in modular dual mobility (MDM) constructs in primary total hip arthroplasties (THAs) from a large volume arthroplasty centre, and determine whether malseating increases the potential for fretting and corrosion at the modular metal interface in malseated MDM constructs using a simulated corrosion chamber. For the clinical arm of the study, observers independently reviewed postoperative radiographs of 551 primary THAs using MDM constructs from a single manufacturer over a three-year period, to identify the incidence of MDM liner-shell malseating. Multivariable logistic regression analysis was performed to identify risk factors including age, sex, body mass index (BMI), cup design, cup size, and the MDM case volume of the surgeon. For the in vitro arm, six pristine MDM implants with cobalt-chrome liners were tested in a simulated corrosion chamber. Three were well-seated and three were malseated with 6° of canting. The liner-shell couples underwent cyclic loading of increasing magnitudes. Fretting current was measured throughout testing and the onset of fretting load was determined by analyzing the increase in average current.Aims
Methods
Cementless acetabular components rely on press-fit fixation for initial stability. In certain cases, initial stability is more difficult to obtain (such as during revision). No current study evaluates how a surgeon’s impaction technique (mallet mass, mallet velocity, and number of strikes) may affect component fixation. This study seeks to answer the following research questions: 1) how does impaction technique affect a) bone strain generation and deterioration (and hence implant stability) and b) seating in different density bones?; and 2) can an impaction technique be recommended to minimize risk of implant loosening while ensuring seating of the acetabular component? A custom drop tower was used to simulate surgical strikes seating acetabular components into synthetic bone. Strike velocity and drop mass were varied. Synthetic bone strain was measured using strain gauges and stability was assessed via push-out tests. Polar gap was measured using optical trackers.Aims
Methods
The aim of our study was to describe the characteristics,
treatment, and outcomes of patients with periprosthetic joint infection
(PJI) and normal inflammatory markers after total knee arthroplasty
(TKA) and
Tribocorrosion at the head–neck taper interface
– so-called ‘taperosis’ – may be a source of metal ions and particulate
debris in metal-on-polyethylene
The primary aim of this paper was to outline the processes involved in building the Partners Arthroplasty Registry (PAR), established in April 2016 to capture baseline and outcome data for patients undergoing arthroplasty in a regional healthcare system. A secondary aim was to determine the quality of PAR’s data. A tertiary aim was to report preliminary findings from the registry and contributions to quality improvement initiatives and research up to March 2019. Structured Query Language was used to obtain data relating to patients who underwent total hip or knee arthroplasty (THA and TKA) from the hospital network’s electronic medical record (EMR) system to be included in the PAR. Data were stored in a secure database and visualized in dashboards. Quality assurance of PAR data was performed by review of the medical records. Capture rate was determined by comparing two months of PAR data with operating room schedules. Linear and binary logistic regression models were constructed to determine if length of stay (LOS), discharge to a care home, and readmission rates improved between 2016 and 2019.Aims
Methods
The purpose of this study was to assess whether
the use of a joint-sparing technique such as curettage and grafting was
successful in eradicating giant cell tumours of the proximal femur,
or whether an alternative strategy was more appropriate. Between 1974 and 2012, 24 patients with a giant cell tumour of
the proximal femur were treated primarily at our hospital. Treatment
was either joint sparing or joint replacing. Joint-sparing treatment
was undertaken in ten patients by curettage with or without adjunctive
bone graft. Joint replacement was by