Advertisement for orthosearch.org.uk
Results 121 - 140 of 198
Results per page:
Bone & Joint 360
Vol. 6, Issue 3 | Pages 35 - 37
1 Jun 2017


The Bone & Joint Journal
Vol. 99-B, Issue 8 | Pages 1028 - 1036
1 Aug 2017
Chawla H Nwachukwu BU van der List JP Eggman AA Pearle AD Ghomrawi HM

Aims

Patellofemoral arthroplasty (PFA) has experienced significant improvements in implant survivorship with second generation designs. This has renewed interest in PFA as an alternative to total knee arthroplasty (TKA) for younger active patients with isolated patellofemoral osteoarthritis (PF OA). We analysed the cost-effectiveness of PFA versus TKA for the management of isolated PF OA in the United States-based population.

Patients and Methods

We used a Markov transition state model to compare cost-effectiveness between PFA and TKA. Simulated patients were aged 60 (base case) and 50 years. Lifetime costs (2015 United States dollars), quality-adjusted life year (QALY) gains and incremental cost-effectiveness ratio (ICER) were calculated from a healthcare payer perspective. Annual rates of revision were derived from the National Joint Registry for England, Wales, Northern Ireland and the Isle of Man. Deterministic and probabilistic sensitivity analysis was performed for all parameters against a $50 000/QALY willingness to pay.


Bone & Joint Research
Vol. 4, Issue 12 | Pages 190 - 194
1 Dec 2015
Kleinlugtenbelt YV Hoekstra M Ham SJ Kloen P Haverlag R Simons MP Bhandari M Goslings JC Poolman RW Scholtes VAB

Objectives

Current studies on the additional benefit of using computed tomography (CT) in order to evaluate the surgeons’ agreement on treatment plans for fracture are inconsistent. This inconsistency can be explained by a methodological phenomenon called ‘spectrum bias’, defined as the bias inherent when investigators choose a population lacking therapeutic uncertainty for evaluation. The aim of the study is to determine the influence of spectrum bias on the intra-observer agreement of treatment plans for fractures of the distal radius.

Methods

Four surgeons evaluated 51 patients with displaced fractures of the distal radius at four time points: T1 and T2: conventional radiographs; T3 and T4: radiographs and additional CT scan (radiograph and CT). Choice of treatment plan (operative or non-operative) and therapeutic certainty (five-point scale: very uncertain to very certain) were rated. To determine the influence of spectrum bias, the intra-observer agreement was analysed, using Kappa statistics, for each degree of therapeutic certainty.


Bone & Joint 360
Vol. 3, Issue 1 | Pages 7 - 10
1 Feb 2014
Stahel PF

The “Universal Protocol” (UP) was launched as a regulatory compliance standard by the Joint Commission on 1st July 1 2004, with the primary intent of reducing the occurrence of wrong-site and wrong-patient surgery. As we’re heading into the tenth year of the UP implementation in the United States, it is time for critical assessment of the protocol’s impact on patient safety related to the incidence of preventable never-events. This article opens the debate on the potential shortcomings and pitfalls of the UP, and provides recommendations on how to circumvent specific inherent vulnerabilities of this widely established patient safety protocol.


Bone & Joint Research
Vol. 5, Issue 9 | Pages 379 - 386
1 Sep 2016
Pahuta M Smolders JM van Susante JL Peck J Kim PR Beaule PE

Objectives

Alarm over the reported high failure rates for metal-on-metal (MoM) hip implants as well as their potential for locally aggressive Adverse Reactions to Metal Debris (ARMDs) has prompted government agencies, internationally, to recommend the monitoring of patients with MoM hip implants. Some have advised that a blood ion level >7 µg/L indicates potential for ARMDs. We report a systematic review and meta-analysis of the performance of metal ion testing for ARMDs.

Methods

We searched MEDLINE and EMBASE to identify articles from which it was possible to reconstruct a 2 × 2 table. Two readers independently reviewed all articles and extracted data using explicit criteria. We computed a summary receiver operating curve using a Bayesian random-effects hierarchical model.


The Bone & Joint Journal
Vol. 98-B, Issue 11 | Pages 1455 - 1462
1 Nov 2016
Matharu GS Berryman F Brash L Pynsent PB Dunlop DJ Treacy RBC

Aims

We investigated whether blood metal ion levels could effectively identify patients with bilateral Birmingham Hip Resurfacing (BHR) implants who have adverse reactions to metal debris (ARMD).

Patients and Methods

Metal ion levels in whole blood were measured in 185 patients with bilateral BHRs. Patients were divided into those with ARMD who either had undergone a revision for ARMD or had ARMD on imaging (n = 30), and those without ARMD (n = 155). Receiver operating characteristic analysis was used to determine the optimal thresholds of blood metal ion levels for identifying patients with ARMD.


The Bone & Joint Journal
Vol. 98-B, Issue 9 | Pages 1289 - 1296
1 Sep 2016
McNally MA Ferguson JY Lau ACK Diefenbeck M Scarborough M Ramsden AJ Atkins BL

Aims

Chronic osteomyelitis may recur if dead space management, after excision of infected bone, is inadequate. This study describes the results of a strategy for the management of deep bone infection and evaluates a new antibiotic-loaded biocomposite in the eradication of infection from bone defects.

Patients and Methods

We report a prospective study of 100 patients with chronic osteomyelitis, in 105 bones. Osteomyelitis followed injury or surgery in 81 patients. Nine had concomitant septic arthritis. 80 patients had comorbidities (Cierny-Mader (C-M) Class B hosts). Ten had infected nonunions.

All patients were treated by a multidisciplinary team with a single-stage protocol including debridement, multiple sampling, culture-specific systemic antibiotics, stabilisation, dead space filling with the biocomposite and primary skin closure.


Bone & Joint 360
Vol. 5, Issue 1 | Pages 28 - 29
1 Feb 2016


Bone & Joint 360
Vol. 5, Issue 1 | Pages 20 - 21
1 Feb 2016


Bone & Joint Research
Vol. 5, Issue 6 | Pages 225 - 231
1 Jun 2016
Yeung M Kowalczuk M Simunovic N Ayeni OR

Objective

Hip arthroscopy in the setting of hip dysplasia is controversial in the orthopaedic community, as the outcome literature has been variable and inconclusive. We hypothesise that outcomes of hip arthroscopy may be diminished in the setting of hip dysplasia, but outcomes may be acceptable in milder or borderline cases of hip dysplasia.

Methods

A systematic search was performed in duplicate for studies investigating the outcome of hip arthroscopy in the setting of hip dysplasia up to July 2015. Study parameters including sample size, definition of dysplasia, outcomes measures, and re-operation rates were obtained. Furthermore, the levels of evidence of studies were collected and quality assessment was performed.


The Bone & Joint Journal
Vol. 98-B, Issue 7 | Pages 892 - 900
1 Jul 2016
Atrey A Heylen S Gosling O Porteous MJL Haddad FS

Joint replacement of the hip and knee remain very satisfactory operations. They are, however, expensive. The actual manufacturing of the implant represents only 30% of the final cost, while sales and marketing represent 40%. Recently, the patents on many well established and successful implants have expired. Companies have started producing and distributing implants that purport to replicate existing implants with good long-term results.

The aims of this paper are to assess the legality, the monitoring and cost saving implications of such generic implants. We also assess how this might affect the traditional orthopaedic implant companies.

Cite this article: Bone Joint J 2016;98-B:892–900.


Bone & Joint 360
Vol. 5, Issue 1 | Pages 32 - 33
1 Feb 2016


Bone & Joint 360
Vol. 4, Issue 6 | Pages 26 - 27
1 Dec 2015

The December 2015 Children’s orthopaedics Roundup360 looks at: Paediatric femoral fractures: a single incision nailing?; Lateral condylar fractures: open or percutaneous?;

Forearm refracture: the risks; Tibial spine fractures; The child’s knee in MRI; The mechanics of SUFE; Idiopathic clubfoot


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 10 | Pages 1308 - 1313
1 Oct 2011
Hart AJ Sabah SA Bandi AS Maggiore P Tarassoli P Sampson B A. Skinner J

Blood metal ions have been widely used to investigate metal-on-metal hip replacements, but their ability to discriminate between well-functioning and failed hips is not known. The Medicines and Healthcare products Regulatory Agency (MHRA) has suggested a cut-off level of 7 parts per billion (ppb).

We performed a pair-matched, case-control study to investigate the sensitivity and specificity of blood metal ion levels for diagnosing failure in 176 patients with a unilateral metal-on-metal hip replacement. We recruited 88 cases with a pre-revision, unexplained failed hip and an equal number of matching controls with a well-functioning hip. We investigated the 7 ppb cut-off level for the maximum of cobalt or chromium and determined optimal mathematical cut-off levels from receiver-operating characteristic curves.

The 7 ppb cut-off level for the maximum of cobalt or chromium had a specificity of 89% and sensitivity 52% for detecting a pre-operative unexplained failed metal on metal hip replacement. The optimal cut-off level for the maximum of cobalt or chromium was 4.97 ppb and had sensitivity 63% and specificity 86%.

Blood metal ions had good discriminant ability to separate failed from well-functioning hip replacements. The MHRA cut-off level of 7 ppb provides a specific test but has poor sensitivity.


Bone & Joint 360
Vol. 2, Issue 6 | Pages 26 - 28
1 Dec 2013

The December 2013 Trauma Roundup360 looks at: Re-operation for intertrochanteric hip fractures; Are twin incisions better than one round the acetabulum?; Salvage osteotomy for calcaneal fractures; Posterior dislocation; Should MRSA be covered in open fractures?; Characterising the saline load test; Has it healed: hip fractures under the spotlight; and stem cells present in atrophic non-union.


The Bone & Joint Journal
Vol. 98-B, Issue 1 | Pages 137 - 143
1 Jan 2016
Hwang JH Varte L Kim HW Lee DH Park H

The aims of this study were to report functional outcomes of salvage procedures for patients with cerebral palsy (CP) who have chronic dislocation of the hip using validated scoring systems, and to compare the results of three surgical techniques.

We reviewed 37 patients retrospectively. The mean age at the time of surgery was 12.2 years (8 to 22) and the mean follow-up was 56 months (24 to 114). Patients were divided into three groups: 14 who underwent proximal femoral resection arthroplasty (PFRA group 1), ten who underwent subtrochanteric valgus osteotomy (SVO group 2), and 13 who underwent subtrochanteric valgus osteotomy with resection of the femoral head (SVO with FHR group 3). All patients were evaluated using the Caregiver Priorities and Child Health Index of Life with Disabilities (CPCHILD) and the Pediatric Quality of Life Inventory (PedsQL).

Significant improvements occurred in most CPCHILD and PedsQL subsection scores following surgery in all patients, without significant differences between the groups. There were 12 post-operative complications. Less severe complications were seen in group 1 than in groups 2 and 3.

Salvage surgery appears to provide pain relief in patients with CP who have painful chronic dislocation of the hip. The three salvage procedures produced similar results, however, we recommend the use of PFRA as the complications are less severe.

Take home message: Salvage surgery can be of benefit to patients with CP with chronic painful hip dislocation, but should be limited to selected patients considering complications.

Cite this article: Bone Joint J 2016;98-B:137–43.


The Bone & Joint Journal
Vol. 98-B, Issue 1 | Pages 14 - 20
1 Jan 2016
Zywiel MG Cherian JJ Banerjee S Cheung AC Wong F Butany J Gilbert C Overgaard C Syed K Jacobs JJ Mont MA

As adverse events related to metal on metal hip arthroplasty have been better understood, there has been increased interest in toxicity related to the high circulating levels of cobalt ions. However, distinguishing true toxicity from benign elevations in cobalt levels can be challenging. The purpose of this review is to examine the use of cobalt alloys in total hip arthroplasty, to review the methods of measuring circulating cobalt levels, to define a level of cobalt which is considered pathological and to review the pathophysiology, risk factors and treatment of cobalt toxicity. To the best of our knowledge, there are 18 published cases where cobalt metal ion toxicity has been attributed to the use of cobalt-chromium alloys in hip arthroplasty. Of these cases, the great majority reported systemic toxic reactions at serum cobalt levels more than 100 μg/L. This review highlights some of the clinical features of cobalt toxicity, with the goal that early awareness may decrease the risk factors for the development of cobalt toxicity and/or reduce its severity.

Take home message: Severe adverse events can arise from the release of cobalt from metal-on-metal arthroplasties, and as such, orthopaedic surgeons should not only be aware of the presenting problems, but also have the knowledge to treat appropriately.

Cite this article: Bone Joint J 2016;98-B:14–20.


The Bone & Joint Journal
Vol. 97-B, Issue 12 | Pages 1593 - 1603
1 Dec 2015
Cool P Ockendon M

Plots are an elegant and effective way to represent data. At their best they encourage the reader and promote comprehension. A graphical representation can give a far more intuitive feel to the pattern of results in the study than a list of numerical data, or the result of a statistical calculation.

The temptation to exaggerate differences or relationships between variables by using broken axes, overlaid axes, or inconsistent scaling between plots should be avoided.

A plot should be self-explanatory and not complicated. It should make good use of the available space. The axes should be scaled appropriately and labelled with an appropriate dimension.

Plots are recognised statistical methods of presenting data and usually require specialised statistical software to create them. The statistical analysis and methods to generate the plots are as important as the methodology of the study itself. The software, including dates and version numbers, as well as statistical tests should be appropriately referenced.

Following some of the guidance provided in this article will enhance a manuscript.

Cite this article: Bone Joint J 2015;97-B:1593–1603.


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1126 - 1131
1 Aug 2015
Nortunen S Flinkkilä T Lantto I Kortekangas T Niinimäki J Ohtonen P Pakarinen H

We prospectively assessed the diagnostic accuracy of the gravity stress test and clinical findings to evaluate the stability of the ankle mortise in patients with supination–external rotation-type fractures of the lateral malleolus without widening of the medial clear space. The cohort included 79 patients with a mean age of 44 years (16 to 82). Two surgeons assessed medial tenderness, swelling and ecchymosis and performed the external rotation (ER) stress test (a reference standard). A diagnostic radiographer performed the gravity stress test.

For the gravity stress test, the positive likelihood ratio (LR) was 5.80 with a 95% confidence interval (CI) of 2.75 to 12.27, and the negative LR was 0.15 (95% CI 0.07 to 0.35), suggesting a moderate change from the pre-test probability. Medial tenderness, both alone and in combination with swelling and/or ecchymosis, indicated a small change (positive LR, 2.74 to 3.25; negative LR, 0.38 to 0.47), whereas swelling and ecchymosis indicated only minimal changes (positive LR, 1.41 to 1.65; negative LR, 0.38 to 0.47).

In conclusion, when gravity stress test results are in agreement with clinical findings, the result is likely to predict stability of the ankle mortise with an accuracy equivalent to ER stress test results. When clinical examination suggests a medial-side injury, however, the gravity stress test may give a false negative result.

Cite this article: Bone Joint J 2015; 97-B:1126–31.


Bone & Joint 360
Vol. 4, Issue 2 | Pages 30 - 32
1 Apr 2015

The April 2015 Children’s orthopaedics Roundup360 looks at: Reducing the incidence of DDH – is ‘back carrying’ the answer?; Surgical approach and AVN may not be linked in DDH; First year routine radiographic follow up for scoliosis not necessary; Diagnosis of osteochondritis dessicans; Telemedicine in paediatrics; Regional anesthesia in supracondylar fractures?