Advertisement for orthosearch.org.uk
Results 121 - 140 of 147
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 7 | Pages 970 - 974
1 Jul 2010
Foruria AM Sperling JW Ankem HK Oh LS Cofield RH

This study was performed to review the safety and outcome of total shoulder replacements in patients who are ≥ 80 years of age. A total of 50 total shoulder replacements in 44 patients at a mean age of 82 years (80 to 89) were studied. Their health and shoulder status, the operation and post-operative course were analysed, including pain, movement, patient satisfaction, medical and surgical complications, radiographs, the need for revision surgery, and implant and patient survival. A total of 27 patients had an ASA classification of III or IV and medical abnormalities were common. Of the 13 shoulders with bony deficiency of the glenoid, nine required grafting. The duration of hospital stay was prolonged and blood transfusions were common. There were no peri-operative deaths. The mean follow-up was for 5.5 years (2 to 12). Pain was significantly reduced (p < 0.001) and movement improved in active elevation and both external and internal rotation (p < 0.001). Using the Neer scale for assessing outcome, 40 (80%) shoulders had an excellent or satisfactory result. There were medical or surgical complications in 17 cases. Four shoulders developed radiological evidence of loosened glenoid components, and three of these had a poor outcome. Three other shoulders required revision, two for instability. By the time of this review 39 of the patients had died from unrelated causes at a mean of 7.5 years (0.8 to 16.4) after surgery.

Total shoulder replacement is a relatively effective treatment in this elderly group of patients. However, there is a requirement for more intense patient care in the peri-operative period, and non-fatal medical or surgical complications are common. Most of these elderly patients will have a comfortable functional shoulder for the rest of their lives.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 11 | Pages 1481 - 1488
1 Nov 2010
Guthrie HC Owens RW Bircher MD

High energy fractures of the pelvis are a challenging problem both in the immediate post-injury phase and later when definitive fixation is undertaken. No single management algorithm can be applied because of associated injuries and the wide variety of trauma systems that have evolved around the world.

Initial management is aimed at saving life and this is most likely to be achieved with an approach that seeks to identify and treat life-threatening injuries in order of priority. Early mortality after a pelvic fracture is most commonly due to major haemorrhage or catastrophic brain injury. In this article we review the role of pelvic binders, angiographic embolisation, pelvic packing, early internal fixation and blood transfusion with regard to controlling haemorrhage.

Definitive fixation seeks to prevent deformity and reduce complications. We believe this should be undertaken by specialist surgeons in a hospital resourced, equipped and staffed to manage the whole spectrum of major trauma. We describe the most common modes of internal fixation by injury type and review the factors that influence delayed mortality, adverse functional outcome, sexual dysfunction and venous thromboembolism.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 6 | Pages 763 - 769
1 Jun 2010
Brown CN Pollard TCB Iyer S Andrade AJMD

Invasive group A streptococcus (iGAS) is the most common cause of monomicrobial necrotising fasciitis. Necrotising infections of the extremities may present directly to orthopaedic surgeons or by reference from another admitting specialty. Recent epidemiological data from the Health Protection Agency suggest an increasing incidence of iGAS infection in England. Almost 40% of those affected had no predisposing illnesses or risk factors, and the proportion of children presenting with infections has risen. These observations have prompted the Chief Medical Officer for the Central Alerting System in England to write to general practitioners and hospitals, highlighting the need for clinical vigilance, early diagnosis and rapid initiation of treatment in suspected cases.

The purpose of this annotation is to summarise the recent epidemiological trends, describe the presenting features and outline the current investigations and treatment of this rare but life-threatening condition.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 11 | Pages 1521 - 1525
1 Nov 2009
Mangat KS Martin AG Bache CE

We compared two management strategies for the perfused but pulseless hand after stabilisation of a Gartland type III supracondylar fracture. We identified 19 patients, of whom 11 were treated conservatively after closed reduction (group 1). Four required secondary exploration, of whom three had median and/or anterior interosseus nerve palsy at presentation. All four were found to have tethering or entrapment of both nerve and vessel at the fracture site. Only two regained patency of the brachial artery, and one patient has a persistent neurological deficit.

In six of the eight patients who were explored early (group 2) the vessel was tethered at the fracture site. In group 2 four patients also had a nerve palsy at presentation and were similarly found to have tethering or entrapment of both the nerve and the vessel. The patency of the brachial artery was restored in all six cases and their neurological deficits recovered completely.

We would recommend early exploration of a Gartland type III supracondylar fracture in patients who present with a coexisting anterior interosseous or median nerve palsy, as these appear to be strongly predictive of nerve and vessel entrapment.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 6 | Pages 835 - 841
1 Jun 2010
Holt G Smith R Duncan K McKeown DW

We have investigated how medical postponement, the time to surgery and the correction of medical abnormalities, according to McLaughlin criteria, before operation affected peri-operative mortality after fracture of the hip. From February to December 2007, in addition to core data, the Scottish Hip Fracture Audit collected information relating to surgical delay. Data were available for 4284 patients which allowed 30-day survival analysis to be performed. Multivariable logistic regression models were used to control for differences in case-mix.

Patients with major clinical abnormalities were more likely to have a postponement and had a lower unadjusted 30-day survival. The time to operation and postponement were not associated with higher mortality after adjustment for case-mix. Correction of major clinical abnormalities before surgery improved the adjusted survival, but this improvement was not significant (p = 0.10). Postponement without correction of a medical abnormality before surgery was associated with a significantly lower (p = 0.006) 30-day adjusted survival. The possible benefits of postponement need to be weighed against prolonged discomfort for the patient and the possibility of the development of other complications.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 3 | Pages 400 - 401
1 Mar 2006
Chen L Soares D

We report a case of fatal pulmonary embolism following a simple ankle fracture in a 17-year-old girl. The diagnosis was confirmed at post-mortem. The risk factors for deep venous thrombosis and pulmonary embolism and their significance in orthopaedic fracture management are discussed.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 532 - 534
1 Apr 2007
Rajpura A Somanchi BV Muir LTSW

We report the effect of padding on the efficiency of the pneumatic tourniquet for the upper limb. Varying thicknesses of two commercially-available types of orthopaedic padding (Cellona and Velband) were applied to the arms of 20 volunteers, with three pressure transducers placed directly beneath the padding. A tourniquet was positioned over the padding and inflated to 220 mmHg.

Significant reductions in the transmitted pressure were recorded from the transducers with both padding materials. With eight layers of padding, reductions in pressure of 13% (1% to 26%) and 18% (7% to 35%) were seen with Cellona and Velband, respectively. The reduction in pressure with Velband padding correlated with increasing arm circumference (Pearson’s correlation coefficient 0.711, p < 0.001).

Studies to date have examined how arm circumference affects the required tourniquet inflation pressure. Our study is the first to investigate the effect of the padding and the findings suggest that using more than two layers results in a significant reduction in the transmitted pressure.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 9 | Pages 1239 - 1242
1 Sep 2007
Mitchell PD Hunt DM Lyall H Nolan M Tudor-Williams G

Panton-Valentine leukocidin secreted by Staphylococcus aureus is known to cause severe skin, soft tissue and lung infections. However, until recently it has not been described as causing life-threatening musculoskeletal infection. We present four patients suffering from osteomyelitis, septic arthritis, widespread intravascular thrombosis and overwhelming sepsis from proven Panton-Valentine leukocidin-secreting Staphylococcus aureus. Aggressive, early and repeated surgical intervention is required in the treatment of these patients.

The Panton-Valentine leukocidin toxin not only destroys host neutrophils, immunocompromising the patient, but also increases the risk of intravascular coagulopathy. This combination leads to widespread involvement of bone with glutinous pus which is difficult to drain, and makes the delivery of antibiotics and eradication of infection very difficult without surgical intervention.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 4 | Pages 474 - 479
1 Apr 2008
Tsirikos AI Howitt SP McMaster MJ

Segmental vessel ligation during anterior spinal surgery has been associated with paraplegia. However, the incidence and risk factors for this devastating complication are debated.

We reviewed 346 consecutive paediatric and adolescent patients ranging in age from three to 18 years who underwent surgery for anterior spinal deformity through a thoracic or thoracoabdominal approach, during which 2651 segmental vessels were ligated. There were 173 patients with idiopathic scoliosis, 80 with congenital scoliosis or kyphosis, 43 with neuromuscular and 31 with syndromic scoliosis, 12 with a scoliosis associated with intraspinal abnormalities, and seven with a kyphosis.

There was only one neurological complication, which occurred in a patient with a 127° congenital thoracic scoliosis due to a unilateral unsegmented bar with contralateral hemivertebrae at the same level associated with a thoracic diastematomyelia and tethered cord. This patient was operated upon early in the series, when intra-operative spinal cord monitoring was not available.

Intra-operative spinal cord monitoring with the use of somatosensory evoked potentials alone or with motor evoked potentials was performed in 331 patients. This showed no evidence of signal change after ligation of the segmental vessels.

In our experience, unilateral segmental vessel ligation carries no risk of neurological damage to the spinal cord unless performed in patients with complex congenital spinal deformities occurring primarily in the thoracic spine and associated with intraspinal anomalies at the same level, where the vascular supply to the cord may be abnormal.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 9 | Pages 1228 - 1233
1 Sep 2008
Ramachandran M Skaggs DL Crawford HA Eastwood DM Lalonde FD Vitale MG Do TT Kay RM

The aim of this retrospective multicentre study was to report the continued occurrence of compartment syndrome secondary to paediatric supracondylar humeral fractures in the period 1995 to 2005. The inclusion criteria were children with a closed, low-energy supracondylar fracture with no associated fractures or vascular compromise, who subsequently developed compartment syndrome. There were 11 patients (seven girls and four boys) identified from eight hospitals in three countries. Ten patients with severe elbow swelling documented at presentation had a mean delay before surgery of 22 hours (6 to 64). One patient without severe swelling documented at presentation suffered arterial entrapment following reduction, with a subsequent compartment syndrome requiring fasciotomy 25 hours after the index procedure.

This series is noteworthy, as all patients had low-energy injuries and presented with an intact radial pulse. Significant swelling at presentation and delay in fracture reduction may be important warning signs for the development of a compartment syndrome in children with supracondylar fractures of the humerus.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 3 | Pages 331 - 334
1 Mar 2006
Haggis P Yates P Blakeway C Fick D Morgan DAF Holt M Wood D

Compartment syndrome is a rare complication of total knee arthroplasty that requires early recognition and prompt decompression in order to prevent long-term disability. We have found only one previous case report in the literature. We present a series of seven cases from four hospitals and five surgeons. Six of the cases resulted in the loss of at least one compartment, and one resulted in amputation. Four of the cases resulted in legal action.

We suggest that important risk factors contributing to the development of this condition include complex surgery, soft-tissue compromise, previous surgery, and possibly vascular disease. Delay in the diagnosis and hence delay in decompression was common in our series, and in five cases appeared to be related to the use of a postoperative epidural infusion for pain relief. The presence of associated neurological compromise may have also been a significant factor in the delay to diagnosis in two cases.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 481 - 485
1 Apr 2007
Church JS Scadden JE Gupta RR Cokis C Williams KA Janes GC

Systemic emboli released during total knee replacement have been implicated as a cause of peri-operative morbidity and neurological dysfunction. We undertook a prospective, double-blind, randomised study to compare the cardiac embolic load sustained during computer-assisted and conventional, intramedullary-aligned, total knee replacement, as measured by transoesophageal echocardiography. There were 26 consecutive procedures performed by a single surgeon at a single hospital. The embolic load was scored using the modified Mayo grading system for echogenic emboli.

Fourteen patients undergoing computer-assisted total knee replacement had a mean embolic score of 4.89 (3 to 7) and 12 undergoing conventional total knee replacement had a mean embolic score of 6.15 (4 to 8) on release of the tourniquet. Comparison of the groups using a two-tailed t-test confirmed a highly significant difference (p = 0.004).

This study demonstrates that computer-assisted knee replacement results in the release of significantly fewer systemic emboli than the conventional procedure using intramedullary alignment.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 1 | Pages 16 - 22
1 Jan 2008
Yates PJ Burston BJ Whitley E Bannister GC

We retrospectively reviewed 175 patients (191 hips) who had undergone primary cemented total hip replacement between November 1992 and November 1995 using a collarless polished double-tapered femoral component after a minimum of ten years (mean 11.08; 10 to 12.8). All stems were implanted using contemporary cementing techniques with a distal cement restrictor, pressurised lavage, retrograde cementing with a gun and proximal pressurisation. Clinical outcome was assessed using the Harris Hip score. Radiological analysis was performed on calibrated plain radiographs taken in two planes. Complete radiological data on 110 patients (120 hips) and clinical follow-up on all the surviving 111 patients (122 hips) was available. The fate of all the hips was known.

At final follow-up, the mean Harris Hip score was 86 (47 to 100), and 87 of 116 patients (75%) had good or excellent scores. Survival with revision of the stem for aseptic loosening as the endpoint was 100%; and survival with revision of the stem for any reason was 95.9% (95% confidence interval 87.8 to 96.8) at ten years. All the stems subsided vertically at the stem-cement interface in a predictable pattern, at an overall mean rate of 0.18 mm per year (0.02 to 2.16), but with a mean rate of 0.80 mm (0.02 to 2.5) during the first year. The mean total subsidence was 1.95 mm (0.21 to 24). Only three stems loosened at the cement-bone interface. There was excellent preservation of proximal femoral bone stock. There was a high incidence of Brooker III and IV heterotopic ossification affecting 25 patients (22%).

The collarless polished tapered stem has an excellent clinical and radiological outcome at a minimum of ten years’ follow-up. The pattern and magnitude of subsidence of the stem within the cement mantle occurred in a predictable pattern, consistent with the design philosophy.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 4 | Pages 427 - 433
1 Apr 2006
van Vugt AB van Kampen A


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 9 | Pages 1173 - 1177
1 Sep 2006
Kean J Wigderowitz CA Coventry DM

We performed a double-blind, randomised controlled trial to assess the effectiveness of a continuous-infusion brachial plexus block with levobupivacaine compared with that of a standard single injection for the management of post-operative pain after surgery on the shoulder.

Eight patients were randomised to receive a pre-operative brachial plexus block using 30 ml of levobupivacaine 0.5% with adrenaline 1:200 000 followed by insertion of a 20-gauge polyamide catheter. This was connected to a disposable elastometric pump, set immediately after surgery to administer a continuous flow of levobupivacaine 0.25% at a rate of 5 ml per hour. The other eight patients were randomised to receive only the initial injection of 30 ml. The study was double-blinded with the aid of sham catheters and clamped pumps.

All patients were given regular paracetamol and were prescribed morphine through a patient-controlled analgesia pump. Motor and sensory block assessments, visual analogue scale pain scores and consumption of morphine were recorded after the operation and then at 6, 12 and 24 hours after administration of the block.

Satisfactory motor and sensory block was achieved in all patients. The mean visual analogue scale pain score at 12 hours and consumption of morphine at 24 hours after injection were significantly lower (p < 0.05) in the continuous-infusion group. This group also took longer to request their first additional analgesia and reported a significantly higher overall level of satisfaction.

Our study has shown that continuous interscalene infusion of levobupivacaine is an effective method of post-operative analgesia after major surgery of the shoulder.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 1 | Pages 117 - 119
1 Jan 2005
Chin T Sawamura S Shiba R Oyabu H Nagakura Y Nakagawa A

We have compared the energy expenditure during walking in three patients, aged between 51 and 55 years, with unilateral disarticulation of the hip when using the mechanical-controlled stance-phase control knee (Otto Bock 3R15) and the microprocessor-controlled pneumatic swing-phase control knee (Intelligent Prosthesis, IP). All had an endoskeletal hip disarticulation prosthesis with an Otto Bock 7E7 hip and a single-axis foot. The energy expenditure was measured when walking at speeds of 30, 50, and 70 m/min.

Two patients showed a decreased uptake of oxygen (energy expenditure per unit time, ml/kg/min) of between 10.3% and 39.6% when using the IP compared with the Otto Bock 3R15 at the same speeds. One did not show any significant difference in the uptake of oxygen at 30 m/min, but at 50 and 70 m/min, a decrease in uptake of between 10.5% and 11.6% was found when using the IP. The use of the IP decreased the energy expenditure of walking in these patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 495 - 502
1 Apr 2007
Hadjipavlou A Tosounidis T Gaitanis I Kakavelakis K Katonis P

Vertebral haemangiomas are usually asymptomatic and discovered fortuitously during imaging. A small proportion may develop variable degrees of pain and neurological deficit. We prospectively studied six patients who underwent eight surgical procedures on 11 vertebral bodies. There were 11 balloon kyphoplasties, six lumbar and five thoracic. The mean follow-up was 22.3 months (12 to 36). The indications for operation were pain in four patients, severe back pain with Frankel grade C paraplegia from cord compression caused by soft-tissue extension from a thoracic vertebral haemangioma in one patient, and acute bleeding causing Frankel grade B paraplegia from an asymptomatic vascular haemangioma in one patient. In four patients the exhibited aggressive vascular features, and two showed lipomatous, non-aggressive, characteristics. One patient who underwent a unilateral balloon kyphoplasty developed a recurrence of symptoms from the non-treated side of the vertebral body which was managed by a further similar procedure.

Balloon kyphoplasty was carried out successfully and safely in all patients; four became asymptomatic and two showed considerable improvement. Neurological recovery occurred in all cases but bleeding was greater than normal. To avoid recurrence, complete obliteration of the lesion with bone cement is indicated. For acute bleeding balloon kyphoplasty should be combined with emergency decompressive laminectomy. For intraspinal extension with serious neurological deficit, a combination of balloon kyphoplasty with intralesional alcohol injection is effective.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 9 | Pages 1128 - 1136
1 Sep 2008
Lemaire R

Several aspects of the management of an orthopaedic surgical patient are not directly related to the surgical technique but are nevertheless essential for a successful outcome. Blood management is one of these. This paper considers the various strategies available for the management of blood loss in patients undergoing orthopaedic and trauma surgery.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 4 | Pages 450 - 453
1 Apr 2005
Reis ND Better OS


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 10 | Pages 1434 - 1438
1 Oct 2005
Eckardt H Ding M Lind M Hansen ES Christensen KS Hvid I

The re-establishment of vascularity is an early event in fracture healing; upregulation of angiogenesis may therefore promote the formation of bone. We have investigated the capacity of vascular endothelial growth factor (VEGF) to stimulate the formation of bone in an experimental atrophic nonunion model.

Three groups of eight rabbits underwent a standard nonunion operation. This was followed by interfragmentary deposition of 100 μg VEGF, carrier alone or autograft.

After seven weeks, torsional failure tests and callus size confirmed that VEGF-treated osteotomies had united whereas the carrier-treated osteotomies failed to unite. The biomechanical properties of the groups treated with VEGF and autograft were identical. There was no difference in bone blood flow.

We considered that VEGF stimulated the formation of competent bone in an environment deprived of its normal vascularisation and osteoprogenitor cell supply. It could be used to enhance the healing of fractures predisposed to nonunion.