The aim of this study was to assess the ability of morphological spinal parameters to predict the outcome of bracing in patients with adolescent idiopathic scoliosis (AIS) and to establish a novel supine correction index (SCI) for guiding bracing treatment. Patients with AIS to be treated by bracing were prospectively recruited between December 2016 and 2018, and were followed until brace removal. In all, 207 patients with a mean age at recruitment of 12.8 years (SD 1.2) were enrolled. Cobb angles, supine flexibility, and the rate of in-brace correction were measured and used to predict curve progression at the end of follow-up. The SCI was defined as the ratio between correction rate and flexibility. Receiver operating characteristic (ROC) curve analysis was carried out to assess the optimal thresholds for flexibility, correction rate, and SCI in predicting a higher risk of progression, defined by a change in Cobb angle of ≥ 5° or the need for surgery.Aims
Methods
The aim of this study is to report the long-term outcomes of instrumented femoral revisions with impaction allograft bone grafting (IBG) using the X-change femoral revision system at 30 years after introduction of the technique. We updated the outcomes of our previous study, based on 208 consecutive revisions using IBG and the X-change femoral revision system in combination with a cemented polished stem, performed in our tertiary care institute between 1991 and 2007. Kaplan-Meier survival analyses were used to determine the survival rate of the revisions with endpoint revision for any reason and aseptic loosening. Secondary outcomes were radiological loosening and patient-reported outcome measures.Aims
Methods
The modified Smith–Petersen and Kocher–Langenbeck
approaches were used to expose the lateral cutaneous nerve of the
thigh and the femoral, obturator and sciatic nerves in order to
study the risk of injury to these structures during the dissection,
osteotomy, and acetabular reorientation stages of a Bernese peri-acetabular
osteotomy. Injury of the lateral cutaneous nerve of thigh was less likely
to occur if an osteotomy of the anterior superior iliac spine had
been carried out before exposing the hip. The obturator nerve was likely to be injured during unprotected
osteotomy of the pubis if the far cortex was penetrated by >
5 mm.
This could be avoided by inclining the osteotome 45° medially and
performing the osteotomy at least 2 cm medial to the iliopectineal
eminence. . The sciatic nerve could be injured during the first and last
stages of the osteotomy if the osteotome perforated the lateral
cortex of ischium and the ilio-ischial junction by >
10 mm. The femoral nerve could be stretched or entrapped during osteotomy
of the pubis if there was significant rotational or linear displacement
of the acetabulum. Anterior or medial displacement of <
2 cm
and lateral
Radiostereometric analysis (RSA) can detect early
micromovement in unstable implant designs which are likely subsequently
to have a high failure rate. In 2010, the Articular Surface Replacement
(ASR) was withdrawn because of a high failure rate. In 19 ASR femoral
components, the mean micromovement over the first two years after implantation
was 0.107 mm (. sd. 0.513) laterally, 0.055 mm (. sd. 0.204)
distally and 0.150 mm (. sd. 0.413) anteriorly. The mean backward
tilt around the x-axis was -0.08° (. sd. 1.088), mean internal
rotation was 0.165° (. sd. 0.924) and mean varus
We undertook a prospective study to analyse the
outcome of 48 malunited pronation-external rotation fractures of the
ankle in 48 patients (25 females and 23 males) with a mean age of
45 years (21 to 69), treated by realignment osteotomies. The interval
between the injury and reconstruction was a mean of 20.2 months
(3 to 98). . In all patients, valgus malalignment of the distal tibia and
malunion of the fibula were corrected. In some patients, additional
osteotomies were performed. Patients were reviewed regularly, and
the mean follow-up was 7.1 years (2 to 15). . Good or excellent results were obtained in 42 patients (87.5%)
with the benefit being maintained over time. Congruent ankles without
a
The patellar clunk syndrome describes painful catching, grinding or jumping of the patella when the knee moves from a flexed to an extended position after total knee replacement (TKR). The posterior stabilised TKR had been noted to have a higher incidence of this problem. Mobile-bearing posteriorly stabilised TKRs have been introduced to improve patellar tracking and related problems by a mechanism of self-alignment. We evaluated the patellar clunk syndrome in 113 knees in 93 patients with such a TKR at a mean follow-up of 2.3 years (2.0 to 3.2). The syndrome was identified in 15 knees (13.3%). Logistic regression analysis showed that the absolute value of the post-operative angle of patellar
The medial rotation contracture caused by weak external rotation secondary to obstetric brachial plexus injury leads to deformation of the bones of the shoulder. Scapular hypoplasia, elevation and rotation deformity are accompanied by progressive dislocation of the humeral head. Between February and August 2005, 44 children underwent a new surgical procedure called the ‘triangle
Adverse spinal motion or balance (spine mobility) and adverse pelvic mobility, in combination, are often referred to as adverse spinopelvic mobility (SPM). A stiff lumbar spine, large posterior standing pelvic tilt, and severe sagittal spinal deformity have been identified as risk factors for increased hip instability. Adverse SPM can create functional malposition of the acetabular components and hence is an instability risk. Adverse pelvic mobility is often, but not always, associated with abnormal spinal motion parameters. Dislocation rates for dual-mobility articulations (DMAs) have been reported to be between 0% and 1.1%. The aim of this study was to determine the early survivorship from the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) of patients with adverse SPM who received a DMA. A multicentre study was performed using data from 227 patients undergoing primary total hip arthroplasty (THA), enrolled consecutively. All the patients who had one or more adverse spine or pelvic mobility parameter had a DMA inserted at the time of their surgery. The mean age was 76 years (22 to 93) and 63% were female (n = 145). At a mean of 14 months (5 to 31) postoperatively, the AOANJRR was analyzed for follow-up information. Reasons for revision and types of revision were identified.Aims
Methods
Adult presentation of neglected congenital muscular torticollis is rare. We report 12 patients with this condition who underwent a modified Ferkel’s release comprising a bipolar release of sternocleidomastoid with Z-lengthening. They had a mean age of 24 years (17 to 31) and were followed up for a minimum of two years. Post-operatively a cervical collar was applied for three weeks with intermittent supervised active assisted exercises for six weeks. Outcome was assessed using a modified Lee score and a Cheng and Tang score. The mean pre-operative rotational deficit was 8.25° (0° to 15°) and mean lateral flexion deficit was 20.42° (15° to 30°), which improved after treatment to a mean of 1.67° (0° to 5°) and 7.0° (4° to 14°) after treatment, respectively. According to the modified Lee scoring system, six patients had excellent results, two had good results and four had fair results, and using the Cheng and Tang score, eight patients had excellent results and four had good results. Surgical management of adult patients with neglected congenital muscular torticollis using a modified Ferkel’s bipolar release gives excellent results. The range of neck movement and head
We hypothesised that a large acromial cover with
an upwardly
Recurrent dislocation is both a cause and consequence of glenoid bone loss, and the extent of the bony defect is an indicator guiding operative intervention. Literature suggests that loss greater than 25% requires glenoid reconstruction. Measuring bone loss is controversial; studies use different methods to determine this, with no clear evidence of reproducibility. A systematic review was performed to identify existing CT-based methods of quantifying glenoid bone loss and establish their reliability and reproducibility A Preferred Reporting Items for Systematic reviews and Meta-Analyses-compliant systematic review of conventional and grey literature was performed.Aims
Methods
Registry studies on modified acetabular polyethylene (PE) liner designs are limited. We investigated the influence of standard and modified PE acetabular liner designs on the revision rate for mechanical complications in primary cementless total hip arthroplasty (THA). We analyzed 151,096 primary cementless THAs from the German Arthroplasty Registry (EPRD) between November 2012 and November 2020. Cumulative incidence of revision for mechanical complications for standard and four modified PE liners (lipped, offset, angulated/offset, and angulated) was determined using competing risk analysis at one and seven years. Confounders were investigated with a Cox proportional-hazards model.Aims
Methods
This single-blinded randomised controlled trial
investigated whether one design of mobile-bearing (MB) total knee replacement
(TKR) has any advantage over a fixed-bearing (FB) design on long-term
fixation as measured by radiostereometry. The amount of wear underneath
the mobile bearing was also evaluated. A series of 42 knees was randomised
to MB or FB tibial components with appropriate polyethylene inserts
and followed for between ten and 12 years, or until the death of
the patient. The polyethylene in the MB group was superior in that
it was gamma-irradiated in inert gas and was calcium-stearate free;
the polyethylene in the FB group was gamma-irradiated in air and
contained calcium stearate. In theory this should be advantageous
to the wear rate of the MB group. At final follow-up the overall
mean migration was 0.75 mm (. sd. 0.76) in the MB group and
0.66 mm (. sd. 0.4) in the FB group, with the FB group demonstrating
more posterior
In computer simulations, the shape of the range of motion (ROM) of a stem with a cylindrical neck design will be a perfect cone. However, many modern stems have rectangular/oval-shaped necks. We hypothesized that the rectangular/oval stem neck will affect the shape of the ROM and the prosthetic impingement. Total hip arthroplasty (THA) motion while standing and sitting was simulated using a MATLAB model (one stem with a cylindrical neck and one stem with a rectangular neck). The primary predictor was the geometry of the neck (cylindrical vs rectangular) and the main outcome was the shape of ROM based on the prosthetic impingement between the neck and the liner. The secondary outcome was the difference in the ROM provided by each neck geometry and the effect of the pelvic tilt on this ROM. Multiple regression was used to analyze the data.Aims
Methods
We investigated the development of CT-based bony
radiological parameters associated with femoroacetabular impingement
(FAI) in a paediatric and adolescent population with no known orthopaedic
hip complaints. We retrospectively reformatted and reoriented
225 abdominal CTs into standardised CT pelvic images with neutral
pelvic